Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 10201 BEACON AVE S - TABERNACLE OF PRAISE - PERMITS AND PLANS
10201 BEACON AVE S ASSOCIATED PERMITS 14-F-226 SITE LOCATION Site Address: CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** 10201 Beacon Ave S King Co. Assessor's Tax No.:0323049212 Suite Number: Floor: Tabernacle of Praise Tenant Name: New Tenant? Q- Yes 9 - No Tabernacle of Praise Property Owner's Name: 10201 Beacon Ave S , TUKWILA, WA 98178 Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name:Wendy Coile/ Jennifer Covello Company Name: TYCO INTEGRATED SECURITY LLC Day Telephone:253-620-5971 11824 NORTH CREEK PKWY N # 105, BOTHELL WA 98011 Mailing Address: City State Zip E-mail Address: Fax Number:888-400-0383 wcoile@tyco.com / jennifer@nwpermit.com Valuation of Project (contractor's bid price): $ Replace existing fire panel,key pad, dialer and smoke detector Scope of Work (please provide detailed information): connecting to existing devices. contact # 206 760-1163 Sherrel Bingham or Bernice Cooper (206) 854-0038 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 206-774-9499 Print Name: Day Telephone: Plan Permit App.doc 5/14/10 TFD FP Form 8 /oz'o/ 0 0 .0 .0 0 .2 0 a 1 .0 L)1 �1A 0 0 •0 C �, 0 0` > 0 •0 � V c c L O 0 O Nw- y,,, CO © �►'aN O o O a) 0 V 'aro 4 5 2 CB aC tC 0 0 N d Cas N c c (0 . es= O 0 a ;a 0 V o0. 0 o m 4) Q, o a -to 0 roy .N CN) 0 O) 4' 3 a 0 c viokiLli O. 111 C r v v O F- fl. SCOPE OF WORK C TUKWILA FIRE c O' 0 co 'iy a) c .z c ca o co a n 0) E 0 0 cc 0 F- a3 G C 0) c C ,a a8 0 9 C O. 2 C ` c oF- cm flO ai N .c c c --0c •ro�,a a) ca a8 ,,Nd 0 0 0.- .D "O o00 co 0)m c CD "0 a , pcc Jo( a3) 0 y a Q c o E m aN) E x ..8E o S o c_c a) 0 0 > n t c 0 E 0 0 m N m v U °' y U 0 N N N 0 0 53 C Y 0�a)3r)c'DNO t t $ o ctp_gEoetx modE .., 0 .c uQ. 6 ,��c 0 ' oarmcE It 0z axi a) _c o v w. E' M� 41 N ro fn � +.+ � C 0 2 C N a in roc°co ?c3 XONc._ � c ro ° .campo (7)00-6-4).-28.g o v °-N'_° c CDQ1.-N O N C-0 0 O +' j Q ro N._ 'CO• m U a N_ Q C O .p. O O •0 la ++ LL ...,. E p 2 7'0(4°-8c°+mN�Oc8°88 C)dC�°c*O ca 0"=F-� c<0i-h1-F-- coo 0 fl N 0 0 '0 5, a. (j c�cVm 00.,-'c�iri4uiccrao0i ET =W62 a� a �E .4 RS IS E E O C E C C co .5 E L V 7. w C �: •00 .� O ''xOi . ' m W U) 0 (1) 0. in W 0 F - d N 0 0 0 MSALDANA Report Generated for: Honeywell VISTA -1 28FBP/ Vi 28FBP-24 Commercial Fire and Partitioned Burglary Alarm. Control Panel Designed to integrate seamlessly with CCTV, access control, and ADEMCO's full range of fire and burglary components, the NEW VISTA-128FBP provides the ultimate protection of life and property. The UL listed Commercial Fire and Burglary Control Platform controls up to eight partitions, and supports up to 128 zones/points using hardwired, wireless and V Plex addressable technologies. A diverse line of ADEMCO initiating devices, notification circuits, digital dialers, FEATURE S keypads, RF receivers and relays are supported by extremely powerful control platform:The VISTA-128FBP has been designed to mount quickly and easily in an attack resistant cabinet, and is available in 12V and 24V models. A revolutionary new feature called Panel Linking allows multiple partitions, panels — even buildings to be armed, disarmed and have status checked from one location. • Eight hardwired zones standard, expandable to 120 V-Plex addressable points/zones or 128 wireless points/zones • Can control eight separate areas independently (8 partitions) • Supports Panel -Linking allows up to 8 systems or buildings to be' controlled from one central location (using VA8200) • Supports commercial UL wireless fire and burg • Stores up to 512 events and can accommodate 150 user codes • Supports addressable V Plex access control points using VistaKey (1 to 8 doors) • Supports up to 16 doors of access control using Vista Gateway Module (VGM)* • Supports CCTV applications with the new VistaView-100 CCTV Switcher Module • Identifies the point or zone of a fire or alarm, using the new FSA- 8/FSA-24 Fire System Annunciator • Programmable to meet SIA false alarm prevention specifications. To meet UL approval forANSI/SiA CP -01-2000 order part number VISTA-128SIA • Two on -board notification (bell) circuits delivering 2.3 amp @12Vor3.4amp ®24V • Automatic smoke detector sensitivity maintenance testing • 4 -wire smoke reset using on- board J2 oufput trigger • Supports Dynamic Signaling for LRR • Supports Remote Control -via the Internet** • Supports Internet Alarm Reporting** • Supports the new Graphical User Interface Consoles • Supports up to 250 access card holders using VistaKey • Supports AlphaNumeric pager up to 8 different numbers using the VA8201 * Connects to Northern Computers Passpoint Access Control Systems. Maximum 32 doors, '* When used with AlarmNet-i VISTA -1 28FBP/V1 28FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel Additional Features • Notification Appliance Circuits (two): - Programmable - Temporal code compliant - Individually silenceable • Programmable on -board auxiliary relay • SIA false alarm reduction features: - Exit error logic - Exit delay reset - Cross zoning - CaII waiting defeat - Recent close report • Supports commercial hardwired, addressable V Plex polling loop and wireless zones • Hardwired zones - Provides eight style B hardwired zones - EOLR supervised for Fire and UL burglary installations - Supports N.O or N.C. sensors - Individually assignable to any eight partition - Up to 32 two -wire smoke detectors each on zone one and two (64 total) - Up to 50 two -wire glass break detectors on zone eight • Patented addressable V Plex polling loop technology - Supports 120 two -wire zones points - Global polling technology for faster processing - Increased current draw capacity (128mA) - Supervised by panel - Individually assignable to partitions, notification circuit (bell) output or aux relay -- 4,000 ft capability without the use of shielded cable - Extender/Isolation bus module - Two -wire smoke detector zone/group expansion module adds two or four zones - Eight zone - Class A and 8 extender module - Eight zone - Class B extender module - One zone supervised contact monitor module • UL Listed wireless expansion - Supports up to 128 wireless zones/points using 5881ENHC receiver - Supervised by control for check-in signals - Tamper protection for transmitters - Individually assignable up to eight partitions - Supports UL864/NFPA approved wireless smoke detectors • Access Control integration - Full integration with PassPoint Access Control System Complete Gateway interface of Vista and access functions • Up to 8 doors using VistaKey V-Plex Access Control • Event reporting • Local printer of access or VISTA related event • Scheduled uploading of events to central station • Stored events for one call retrieval • Communication - Phone mapping by zone response type - Supports VIP interactive phone voice module - Panel operation during download - Uploading equipment list to central station - Communication to PassPoint via Vista Gateway Module • CCTV integration - Supports VistaView-100 ECP based CCTV switchers Honeywell Applications The VISTA-128FBP control is well suited for a variety of applications as an integrated fire and burglary control. A diverse line of ADEMCO initiating devices supports this extremely powerful control. Some of the applications supported are: medical and professional buildings, churches or synagogues, office buildings, schools, strip malls, larger residences and factory or warehouse environments. Installation The VISTA-128FBP alarm system has been designed to mount both quickly and easily. It meets all applicable requirements for UL commercial fire and burglary installations. Specifications Electrical • Primary power: 18VAC © 72VA ADEMCO No. 1451 • Control panel quiescent current draw: 350mA • Backup battery: -12VDC, 12AH min to 34.4AH max - Lead acid battery (gel type) • Alarm power: 12VDC, 1.7A max for each notification (bell) circuit output Total 2.3amps ®12V • Aux. standby pwr: 12VDC, 1A max • Total power: 2.3A at 12VDC, 3.4A at 24VDC from all sources • Standby time: 24 hours with 1A standby load using 34.4AH battery • Fusing: Battery input, aux. and notification (bell) circuit outputs are protected using PTC circuit protectors. All outputs are power limited. • Optional 24 -volt power supply, PS 24 Supplies two 24 VFW, 1.7A full wave rectified, unfiltered outputsMain Dialer: • Line seize: Double Pole • Ringer equiv.: 0.7B • Formats: ADEMCO Low Speed, ADEMCO 4+2 Express, ADEMCO High Speed, ADEMCO Contact ID, Sescoa and Radionics • Dual phone line capability (using 5140DLM module) Cabinet dimensions • 18"HX 14.5"W X 4.3"D Environmental • Storage temp: -10°C to 70°C • Operating temp: 0°C to 50°C • Hcimidity: 85% RH • EMI: Meets or exceeds the following requirements: - FCC Part 15, Class B Device - FCC Part 68 - IEC EMC Directive Agency Listings Burglary • UL609 Grade A Local Mercantile Premises and Mercantile Safe and Vault • UL611/1610 Grades A, AA, Central Station • UL365 Grades A, AA Police Connect Fire • UL864/NFPA72 Local, Central Station and Remote Station • Factory Mutual • California State Fire Marshal • MEA • UL985 P x X !jig grr��IP � I kl 11 giqiM ji y O §§ •tue 1� 18 gg ggel o 9 J J. 2211 111 E §,a1 1111 d 146 . • . . . • . • • • viiiiithpb i Iugs . a ng 7 • us titfl 40 —; t i 1 4 ao - yli T to o V S ° W s grtIlhiglA� 4V 1111 � � 2 111 1 : » W f . 1 1 1 1 1 U 1 •. . . vizA 8 h ; 11,4 n! 8 Ha oad gigt -1do 12 IN N� 104 inROOJ. ccn I I 1 1 1 dPlli1•r _ � g qo !llhiJh 1 1 1 1 1 1 1 1 Li.a I C `d CO PPP444 03 - s g a $ Q le N, 8`31 11 11111111P 11 0192 p ggi 41,f ili13a1N-11.11 V E m jiSi73os 1 Honeywell VISTA1 28FBP/V1 28FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel SPECIFICATIONS Auxiliary Devices • 6160CR - Red Alpha Keypad • 6139R - Red Alpha Keypad/Annunciator • FSA -8 & FSA -24 annunciator modules • 4204 - Relay Module, four form C contacts • 4204CF - Two supervised output circuits • 5881 Series - RF receiver supporting 5800 wireless detectors • 6220S - System printer used with 4100SM serial module Two -wire smoke detectors conventional • 2100 Series Photoelectric • 2400 Series Photoelectric • 1100 Series Ionization Four -wire smoke detectors conventional • 2112/24 Series Photoelectric • 1412 Series Ionization Horn/Strobes • System Sensor Notification Appliances Manual Pull Stations • 5140MPS-1 ! 5140MPS-2 V Pleat (addressable) Devices • 4208U Loop Expansion Module • - eight zones • 41018N Single Relay/Zone Module • 4208SNF Class NB Expander Module • 4209U Group Zoning Module - two/four zones • 4190SN Remote Point Module - two zones • 4193SN Two Zone Serial Interface Module • 4293SN One Zone Serial Interface Module • 4297 Isolation/Extender Module V Plex (addressable) Smoke Detectors: • 5192SD • 4192SD • 4192CP • 5192SDT • 4192SDT • 4192CPM • 4192SDTM V Pleat Passive Infrared Detectors • 998MX • 4275EX-SN • 4278EX-SN V -Plea (addressable) Contacts • 4939SN-WH • 4944SN-WH • 4959SN V Plex Glassbreak Detectors: • 9500SN VISTA interactive phone module • 4286 Voice Module Optional 24V Power Supply • PS24 - 24V power supply - 3.4A Long Range Radio: • Long Range Radio 7720ULF-XX, 7835C, 7835CF, 7845C Upgraded software • Upgraded Compass Downloader Windows compatible Wireless Devices • 5804BDV - Bi-directional with voice • 5804BD - Bi-directional Key • 5804Watch - Wireless Key & sports watch combined • 5816 - Door/Window Transmitter • 5804 - Wireless key • 5827BD - Bi-directional Keypad • 5890 - PIR • 5849 - Glassbreak Detector • 5819 - Shock.Sensor Commercial Wireless Devices • 5808LST - Wireless Smoke Detector • 5809 - Wireless Heat Detector • 5817CB - Wireless Commercial Transmitter • 5869 - Hold -Up Transmitter • 5881ENHC - Commercial Fire/Burg Receiver Access Control • VistaKey V Plex (addressable) Access Control • VistaKey-SK Starter Kit • VistaKey-EX Expansion Kit • VGM Vista Gateway Module to PassPoint Access Control (Northern Computers) CCTV - VistaView-100 CCTV Switcher or Module Internet Access • Graphical user interface with Internet capability • Internet Remote Control - Networking Module • Internet Alarm Communicator (7845i) Paging • VA8201 AlphaNumeric Pager ORDERING VISTA 128FBP Commercial Fire and Partitioned Burglary Alarm Control Panel 12V Model V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel 24V Model. Honeywell Security & Custom Electronics 165 Eileen Way, Syosset, NY 11791 www.honeywell.com/security Copyright 02003 Honeywell lnteensionel loc. U 128F8PID WIN 5193SD/5193SDT V-PLEX® ADDRESSABLE SMOKE DEI ECTOR Honeywell Honeywell's 5193SD/SDT Addressable Photoelectric Smoke Detector is designed to provide open area protection and to be used with compatible UL -listed Honeywell control panels that support V-Plex technology. The detector incorporates a state-of-the-art optical sensing chamber and an advanced microprocessor. Built-in Drift Compensation algorithms automatically maintain proper operation at factory calibrated detection levels, even when sensitivity Is altered due to the presence of contaminates settling into the units chamber. The 5193SDT also features a restorable, built-in, fixed temperature (135° F/57.2° C) thermal detector. FEATURES • Easy Installation: Installation of the 5193SD/SOT detector is simplified by the use of a mounting base that may be pre -wired to the system, allowing the detector to be easily installed or removed for maintenance or service. (See Figure 1). • LED Status Indicators: Two LEDs (green and red) provide local visual indication of the detectors status — including normal operation, alarm, out of sensitivity and trouble conditions. • Test button: This button allows the user to perform periodic testing of the detector's circuitry and verify that the detector is within the sensitivity limits. • Versatile Mounting: Mounting Is made simple with the Included hardware and the large mounting ports, which accommodate drywall anchors for easy surface mounting. (See Figure 1), • Tamper Protection and Tamper Resistance: The detector contains a built -In tamper switch that can communicate back to the control panel In the event the detector is removed from its base. For an added level of security, the detector also Includes a tamper resistant element that prevents removal from the base without the use of tools. (See Figure 1). DIRECT MOUNT HOLES TAMPER RELEASE TAB SNAP OFF TAB FOR TAMPER LOCK Figure 1: Tamper -Resistant Feature/Wiring 5193SD/5193SDT V PLEX® ADDRESSABLE SMOKE DE I ECTOR SPECIFICATIONS • Heat Sensor: (Model 5193SDT): 135° F (57.2° C); Fixed Temperature Electronic Thermistors • Operating Ambient Temperature Range: 32° to 100° F (0° to 38° C) • Operating Humidity Range: 0 to 95% RH non -condensing • Storage Temperature Range: -4° to 158° F (-20° to 70°C) ACCESSORY (sold separately) • Diameter (including base): 5.3 inches • Height (including base): 2.0 inches • Weight 6.3 oz. • Agency Listing: UL -268 • System Voltage Range: 7-14V • Standby Current (maximum @ 12V) LED off: 1.2mA LED on: 2.8mA To measure the detector's sensitivity, the SENS-RDR Infrared Sensitivity Reader tool (sold separately) should be used. It reduces testing time, simplifies sensitivity measurements and displays them precisely in terms of percent per foot obscuration. The SENS-RDR eliminates the need for magnets, voltmeters and ladders. ORDERING 5193SD 5193SDT Figure 2 Position of Reader Addressable Photoelectric Simko Detector Addressable Photoelectric Smoke Detector with Integral Heat Sensor.' Accessory sold separately: SENS-RDR Handheld Sensitivity.. Header Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 www.honeywell.com U6193SDT/D May 2009 0 2009 Honeywell International no. Honeywell Honeywell VISTA -1 28FBP/ Vi 28FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel Designed to integrate seamlessly with CCN, access control, and ADEMCO's full range of fire and burglary components, the NEW VISTA-128FBP provides the ultimate protection of life and property. The UL listed Commercial Fire and Burglary Control Platform controls up to eight partitions, and supports up to 128 zones/points using hardwired, wireless and V-Plex addressable technologies. A diverse line of ADEMCO initiating devices, notification circuits, digital dialers, FEATURES keypads, RF receivers and relays are supported by extremely powerful control platform: The VISTA-128FBP has been designed to mount quickly and easily in an attack resistant cabinet, and is available in 12V and 24V models. A revolutionary new feature called Panel Linking allows multiple partitions, panels — even buildings to be armed, disarmed and have status checked from one location. • Eight hardwired zones standard, expandable to 120 V-Plex addressable points/zones or 128 wireless points/zones • Can control eight separate areas independently (8 partitions) • Supports Panel -Linking allows up to 8 systems or buildings to be' controlled from one central location (using VA8200) • Supports commercial UL wireless fire and burg • Stores up to 512 events and can accommodate 150 user codes • Supports addressable V-Plex access control points using VistaKey (1 to 8 doors) • Supports up to 16 doors of access control using Vista Gateway Module (VGM)* • Supports CCTV applications with the new VistaView-100 CCTV Switcher Module • Identifies the point or zone of a fire or alarm, using the new FSA- 8/FSA-24 Fire System Annunciator • Programmable to meet SIA false alarm prevention specifications. To meet UL approval forANSI/SIA CP -01-2000 order part number VISTA-128SIA • Two on -board notification (bell) circuits delivering 2.3 amp ® 12Vor3.4amp ®24V • Automatic smoke detector sensitivity maintenance testing • 4 -wire smoke reset using on- board J2 oufput trigger • Supports Dynamic Signaling for LRR • Supports Remote Control-vicl the Internet** • Supports Internet Alarm Reporting** • Supports the new Graphical User interface Consoles . • Supports.up to 250 access card holders using VistaKey • Supports AlphaNumeric pager up to 8 different numbers using the VA8201 * Connects to Northern Computers Passpofnt Access Control Systems. Maximum 32 doors. **When used with AlarmNet-f VISTA -1 28FBP/V1 28FBP24 Commercial Fire and Partitioned Burglary Alarm Control Panel Additional Features • Notification Appliance Circuits (two): - Programmable - Temporal code compliant - Individually silenceable • Programmable on -board auxiliary relay • SIA false alarm reduction features: - Exit error logic - Exit delay reset - Cross zoning - Call waiting defeat - Recent close report • Supports commercial hardwired, addressable V Plex polling loop and wireless zones • Hardwired zones -- Provides eight style B hardwired zones - EOLR supervised for Fire and UL burglary installations - Supports N.O or N.C. sensors - Individually assignable to any eight partition - Up to 32 two -wire smoke detectors each on zone one and two (64 total) - Up to 50 two -wire glass break detectors on zone eight • Patented addressable V Plex polling loop technology - Supports 120 two -wire zones points - Global polling technology for faster processing - Increased current draw capacity (128mA) - Supervised by panel - Individually assignable to partitions, notification circuit (bell) output or aux relay - 4,000 ft capability without the use of shielded cable - Extender/Isolation bus module - Two -wire smoke detector zone/group expansion module adds two or four zones - Eight zone - Class A and B extender module - Eight zone - Class B extender module - One zone supervised contact monitor module • UL Listed wireless expansion - Supports up to 128 wireless zones/points using 5881 ENHC receiver - Supervised by control for check-in signals - Tamper protection for transmitters - Individually assignable up to eight partitions •-.., i0"lit -•10. 4+'40 5192 Series Sod Detectors - Supports UL864/NFPA approved wireless smoke detectors • Access Control integration - Full integration with PassPoint Access Control System Complete Gateway interface of Vista and access functions • Up to 8 doors using VistaKey V Plex Access Control • Event reporting • Local printer of access or VISTA related event • Scheduled uploading of events to central station • Stored events for one call retrieval • Communication - Phone mapping by zone response type - Supports VIP interactive phone voice module - Panel operation during download - Uploading equipment list to central station - Communication to PassPoint via Vista Gateway Module • CCTV integration - Supports VistaView-100 ECP based CCTV switchers 41935N Sedal Interface Module Paralel Printer V-PLEX own Bedew92 Smoke Detectors 09 921h Pass A Zones R4�1A{v I ��` l:IndrR 420 }Me1d�10 Eight lass B Hardware Zones WW1 Statue Module 418 5140 LE0 elle iki!p; 441C3SerM Interlace t, Module Honeywell ECP Boa Applications The VISTA-128FBP control is well suited for a variety of applications as an integrated fire and burglary control. A diverse line of ADEMCO initiating devices supports this extremely powerful control. Some of the applications supported are: medical and professional buildings, churches or synagogues, office buildings, schools, strip malls, larger residences and factory or warehouse environments. Installation The VISTA-128FBP alarm system has been designed to mount both quickly and easily. It meets all applicable requirements for UL commercial fire and burglary installations. Specifications Electrical • Primary power: 18VAC @ 72VA ADEMCO No. 1451 • Control panel quiescent current draw: 350mA • Backup battery: - 12VDC, 12AH min to 34.4AH max - Lead acid battery (gel type) V NIP sonar eon Expander Module 5881 (Mmc keYPed Stgarvlsed MAC MahleViiii .,.� A b ial22-°w Stroke nadedors • Alarm power: 12VDC, 1.7A max for each notification (bell) circuit output Total 2.3amps ®12V • Aux. standby pwr: 12VDC, 1A max • Total power: 2.3A at 12VDC, 3.4A at 24VDC from all sources • Standby time: 24 hours with IA standby Toad using 34.4AH battery • Fusing: Battery input, aux. and notification (bell) circuit outputs are protected using PTC circuit . protectors. All outputs are power limited. • Optional 24 -volt power supply, PS 24 Supplies two 24 VFW, 1.7A full wave rectified, unfiltered outputsMain Dialer: • Line seize: Double Pole • Ringer equiv.: 0.7B • Formats: ADEMCO Low Speed, ADEMCO 4+2 Express, ADEMCO High Speed, ADEMCO Contact ID, Sescoa and Radionics • Dual phone line capability (using 5140DLM module) V-PlexAdaph:r 494494 rrSmoke 11 DedeGore 5890 wreka PIR 0 °44.1 : Coorffiladow naT e, Smoke 680 Weston Cabinet dimensions • 18"H X 14.5"W X 4.3"D Environmental • • Storage temp: -10°C to 70°C • Operating temp: 0°C to 50°C • Humidity: 85% RH • EMI: Meets or exceeds the following requirements: - FCC Part 15, Class B Device - FCC Part 68 - IEC EMC Directive • Agency Listings Burglary • UL609 Grade A Local Mercantile Premises and Mercantile Safe and Vault • UL611/1610 Grades A, M, Central Station • UL365 Grades A, AA Police Connect Fire • UL864/NFPA72 Local, Central Station and Remote Station • Factory Mutual • California State Fire Marshal • MEA • UL985 Man0al Pull sa8oea —ci 614014P$-1• -CI s14OMPs.r —a Tamper 9Mtct --r] Flow SMil h' -0 Low Temp swath• G 421J3U nota Zankg Supports Convangonsi & Smoke Dole:tors Wie VGA LWOM) VIS Panel Llokig Module P anel Lk Idnp Mahle omit- 4297 IsoleSolY Extender Module 41965N No-zaw expender U g N Y O 9; t A Hi a a a M a si g ara ill 1 a 11 $X Eg li.EEA .1 i ga 1 i ''4 1 I 1RP Oh i h n:5 n a gga ¢ "i- - aY o th 3 110 w Ig- a; W0 !RI a 1Iid D § lig li Yi ;el 1lL :11gili ¢MI ; of m A aa1 lik14; ilgi lilliMitifIl iiai UIhIIIJIIIJ v h of s IIJIIIJ 1 d ---t a c) g o 6 3 g 81 ( X11 mag i'34 � II I �� ;g ��� I5 --(1( iVolb 15 I• J ai (�,) � 4gt- !211 1 1 I I !1 111 lb I '101 Oil all 71- r� Nr it :lip I 1-10( 04 t.1 Z liiii- 1J 41 um 111 i a 1 1 meiC'4 3 s. g 1 1. $ 8 h 131 L a �� m 1a 13af a 1 en. t. i - 5411 qlg g § la plinoY laM AliA `tel hiNillaiiiiiiillth T 1 il 0 Li p. 1 r h g .}p713 m it m �iS2• � U 11; 1 10is rill r go 2_• s s- FIsill illinliiigi 8 •• 1 1 1 1 1 J I I I 1 I n I 1 1 I 111 40. 1111.111, Honeywell VISTA -1 28FBP/V1 28FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel SPECIFICATIONS Ainci 1ary Devices • 6160CR - Red Alpha Keypad • 6139R - Red Alpha Keypad/Annunciator • FSA -8 & FSA -24 annunciator modules • 4204 - Relay Module, four form C contacts • 4204CF - Two supervised output circuits • 5881 Series - RF receiver supporting 5800 wireless detectors • 6220S - System printer used with 4100SM serial module Two -wire smoke detectors conventional • 2100 Series Photoelectric • 2400 Series Photoelectric • 1100 Series Ionization Four -wire smoke detectors conventional • 2112/24 Series Photoelectric • 1412 Series Ionization Horn/Strobes • System Sensor Notification Appliances Manual Pull Stations • 5140MPS-1 r 5140MPS-2 V-Plex (addressable) Devices • 4208U Loop Expansion Module - eight zones • 4101SN Single Relay/Zone Module • 4208SNF Class A/B Expander Module • 4209U Group Zoning Module - two/four zones • 4190SN Remote Point Module - two zones • 4193SN Two Zone Serial Interface Module • 4293SN One Zone Serial interface Module • 4297 Isolation/Extender Module V-Plex (addressable) Smoke Detectors: • 5192SD • 4192SD • 4192CP • 5192SDT • 4192SDT • 4192CPM • 4192SDTM V-Plex Passive Infrared Detectors • 998MX • 4275EX-SN • 4278EX-SN V-Plex (addressable) Contacts • 4939SN-WH • 49448N -WH • 4959SN V-Plex Glassbreak Detectors: • 9500SN VISTA interactive phone module • 4286 Voice Module Optional 24V Power Supply • PS24 - 24V power supply - 3.4A Long Range Radio: • Long Range Radio 7720ULF-XX, 7835C, 7835CF, 7845C Upgraded software • Upgraded Compass Downloader Windows compatible Wireless Devices • 5804BDV - Bi-directional with voice • 5804BD - Bi-directional Key 5804Watch - Wireless Key & sports watch combined • 5816 - Door/Window Transmitter • 5804 - Wireless key • 5827BD - Bi-directional Keypad • 5890 - PIR • 5849 -- Glassbreak Detector • 5819 - Shock.Sensor Commercial Wireless Devices • 5808LST - Wireless Smoke Detector • 5809 - Wireless Heat Detector • 5817CB - Wireless Commercial Transmitter • 5869 - Hold -Up Transmitter • 5881 ENHC - Commercial Fire/Burg Receiver Access Control • VistaKey V-Plex (addressable) Access Control • VistaKey-SK Starter Kit • VistaKey-EX Expansion Kit • VGM Vista Gateway Module to PassPoint Access Control (Northern Computers) CCTV - VistaView-100 CCTV Switcher or Module Internet Access • Graphical user interface with internet capability • Internet Remote Control - Networking Module • Internet Alarm Communicator (7845i) Paging • VA8201 AlphaNumeric Pager ORDERING VISTA 128FBP Commercial Fire and Partitioned Burglary Alarm Control Panel 12V Model V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel 24V Model Honeywell Security & Custom Electronics 165 Eileen Way, Syosset, NY 11791 www.honeywell.com/secarity cwYrklit 02003 Fmnering Internelbnel Inc. L/VI F P/p 854 5193SD/5193SDT V-PLEX® ADDRESSABLE SMOKE DE 1 ECTOR Honeywell Honeywells 5193SD/SDT Addressable Photoelectric Smoke Detector is designed to provide open area protection and to be used with compatible UL -listed Honeywell control panels that support V Plex technology. The detector incorporates a state-of-the-art optical sensing chamber and an advanced microprocessor. Built-in Drift Compensation algorithms automatically maintain proper operation at factory calibrated detection levels, even when sensitivity is altered due to the presence of contaminates settling into the unit's chamber. The 5193SDT also features a restorable, built-in, fixed temperature (135° F/57.2° C) thermal detector FEATURES • Easy Installation: Installation of the 5193SD/SDT detector Is simplified by the use of a mounting base that may be pre -wired to the system, allowing the detector to be easily installed or removed for maintenance or service. (See Figure 1). • LED Status Indicators: Two LEDs (green and red) provide local visual indication of the detector's status — including normal operation, alarm, out of sensitivity and trouble conditions. • Test button: This button allows the user to perform periodic testing of the detector's circuitry and verify that the detector is within the sensitivity limits. • Versatile Mounting: Mounting is made simple with the Included hardware and the large mounting ports, which accommodate drywall anchors for easy surface mounting. (See Figure 1). • Tamper Protection and Tamper Resistance: The detector contains a built-in tamper switch that can communicate back to the control panel In the event the detector Is removed from its base. For an added level of security, the detector also includes a tamper resistant element that prevents removal from the base without the use of tools. (See Figure 1). RELEASE TAB SNAP OFF TAB FOR TAMPER LOC( Figure 1: Tamper -Resistant Feature/Wiring 5193SD/5193SDT V-PLEr ADDRESSABLE SMOKE DETECTOR SPECIFICATIONS • Heat Sensor: (Model 5193SDT): 135° F (57.2° C); Fixed Temperature Electronic Thermistors • Operating Ambient Temperature Range: 32° to 100° F (0° to 38° C) • Operating Humidity Range: 0 to 95% RH non -condensing • Storage Temperature Range: -4° to 158° F (-20° to 70°C) ACCESSORY (sold separately) • Diameter (including base): 5.3 fiches • Height (including base): 2.0 inches • Weight 6.3 oz. • Agency Listing: UL -268 • System Voltage Range: 7-14V • Standby Current (maximum @ 12V) LED off: 1.2mA LED on: 2.8mA To measure the detector's sensitivity, the SENS-RDR Infrared Sensitivity Reader tool (sold separately) should be used. It reduces testing time, simplifies sensitivity measurements and displays them precisely in terms of percent per foot obscuration. The SENS-RDR eliminates the need for magnets, voltmeters and ladders. ORDERING 5193SD 5193SDT Figure 2: Position of Reader Addressable Photoelectric Smoke Detector Addressable Photoelectric Smoke Detector with Integral Heat San, Accessory sold separately: SENS-RDR Handheld Sensitivity Read Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 www.honeywell.com U5193S0T/D May 2009 0 2009 Honeywell International Inc. Honeywell Honeywell VISTA -1 28FBP/ Vi 28FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel Designed to integrate seamlessly with CCTV, access control, and ADEMCO's full range of fire and burglary components, the NEW VISTA-128FBP provides the ultimate protection of life and property. The UL listed Commercial Fire and Burglary Control Platform controls up to eight partitions, and supports up to 128 zones/points using hardwired, wireless and V-Plex addressable technologies. A diverse line of ADEMCO initiating devices, notification circuits, digital dialers, FEATURES keypads, RF receivers and relays are supported by extremely powerful control platform. The VISTA-128FBP has been designed to mount quickly and easily in an attack resistant cabinet, and is available in 12V and 24V models. A revolutionary new feature called Panel Linking allows multiple partitions, panels — even buildings to be armed, disarmed and have status checked from one location. • Eight hardwired zones standard, expandable to 120 V-Plex addressable points/zones or 128 wireless points/zones • Can control eight separate areas independently (8 partitions) • Supports Panel -Linking allows up to 8 systems or buildings to be' controlled from one central location (using VA8200) • Supports commercial UL wireless fire and burg • Stores up to 512 events and can accommodate 150 user codes • Supports addressable V Plex access control points using VistaKey (1 to 8 doors) • Supports up to 16 doors of access control using Vista Gateway Module (VGM)* • Supports CCTV applications with the new VistaView-100 CCTV Switcher Module • Identifies the point or zone of a fire or alarm, using the new FSA- 8/FSA-24 Fire System Annunciator • Programmable to meet SIA false alarm prevention specifications. To meet UL approval forANSI/SIA CP -01-2000 order part number VISTA-128SIA • Two on -board notification (bell) circuits delivering 2.3 amp CI) 12Vor3.4amp O24V • Automatic smoke detector sensitivity maintenance testing • 4 -wire smoke reset using on- board J2 output trigger • Supports Dynamic Signaling for LRR • Supports Remote Control -via the internet** • Supports Internet Alarm Reporting** • Supports the new Graphical User interface Consoles • Supports up to 250 access card holders using VistaKey • Supports AiphaNumeric pager up to 8 different numbers using the VA8201 * Connects to Northern Computers Passpoint Access Control Systems. Maximum 32 doors. ** When used with AlarmNet-i VISTA -1 28FBP/V1 28FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel Additional Features • Notification Appliance Circuits (two): - Programmable - Temporal code compliant - lndividually silenceable • Programmable on -board auxiliary relay • SIA false alarm reduction features: - Exit error logic - Exit delay reset - Cross zoning - Call waiting defeat - Recent close report • Supports commercial hardwired, addressable V Plex polling loop and wireless zones • Hardwired zones - Provides eight style B hardwired zones - EOLR supervised for Fire and UL burglary installations - Supports N.O or N.C. sensors - Individually assignable to any eight partition - Up to 32 two -wire smoke detectors each on zone one and two (64 total) - Up to 50 two -wire glass break detectors on zone eight • Patented addressable V-Plex polling loop technology - Supports 120 two -wire zones points - Global polling technology for faster processing - Increased current draw capacity (128mA) - Supervised by panel - Individually assignable to partitions, notification circuit (bell) output or aux relay - 4,000 ft capability without the use of shielded cable - Extender/Isolation bus module - Two -wire smoke detector zone/group expansion module adds two or four zones - Eight zone - Class A and B extender module - Eight zone - Class B extender module - One zone supervised contact monitor module • UL Listed wireless expansion - Supports up to 128 wireless zones/points using 5881ENHC receiver - Supervised by control for check-in signals - Tamper protection for transmitters - Individually assignable up to eight partitions 5182 Serbs Smoke Detectors ON." - Supports UL864/NFPA approved wireless smoke detectors • Access Control integration - Full integration with PassPoint Access Control System Complete Gateway interface of Vista and access functions • Up to 8 doors using VistaKey V Plex Access Control • Event reporting • Local printer of access or VISTA related event • Scheduled uploading of events to central station • Stored events for one call retrieval • Communication - Phone mapping by zone response type - Supports VIP interactive phone voice module - Panel operation during download - Uploading equipment list to central station - Communication to PassPoint via Vista Gateway Module • CCTV integration - Supports VistaView-100 ECP based CCTV switchers Parallel Printer Serle) Printer Alpha Paging Module LoopIX 5182 Sense Smoke Detectors 5881 W581ese Receiver 4208SNF Eight -Zone Expenpan MoCla 4YIl 2 Class A Zones 61 N. 4204 Vie 100 SWirater 5 NAC (BeA1 Mv4CF prcutl t: ,. L Elgfr Class R hbroeare zones RS232 Noeecolicn Appliances Phone tine to Cental Salton 772OLLF Loop Flange Radiocaller Honeywell Applications The VISTA-128FBP control is well suited for a variety of applications as an integrated fire and burglary control. A diverse line of ADEMCO initiating devices supports this extremely powerful control. Some of the applications supported are: medical and professional buildings, churches or synagogues, office buildings, schools, strip malls, larger residences and factory or warehouse environments. Installation The VISTA-128FBP alarm system has been designed to mount both quickly and easily. It meets all applicable requirements for UL commercial fire and burglary installations. Specifications Electrical • Primary power: 18VAC 0) 72VA ADEMCO No. 1451 • Control panel quiescent current draw: 350mA • Backup battery: - 12VDC, 12AH min to 34.4AH max - Lead acid battery (gel type) Serial Interlace Module ECP Bus 5881 41905N '. Expenderzone • Alarm power: 12VDC, 1.7A max for each notification (bell) circuit output Total 2.3amps ® 12V • Aux. standby pwr: 12VDC, 1A max • Total power: 2.3A at 12VDC, 3.4A at 24VDC from all sources • Standby time: 24 hours with 1A standby Toad using 34.4AH battery • Fusing: Battery input, aux. and notification (bell) circuit outputs are protected using PTC circuit protectors. AH outputs are power limited. • Optional 24 -volt power supply, PS 24 Supplies two 24 VFW, 1.7A full wave rectified, unfiltered outputsMain Dialer: • Line seize: Double Pole • Ringer equiv.: 0.7B • Formats: ADEMCO Low Speed, ADEMCO 4+2 Express, ADEMCO High Speed, ADEMCO Contact ID, Sescoa and Radionics • Dual phone line capability (using 5140DLM module) Ptea pta 49rs4a4sSeNttee Re`esea ga • r Smoke Detectors 581 DoorMindow Miniature Transmitter Wri as PIR mem Stroke Detectors 42060 Grit( zatnp 01 240 Aei- lm▪ iZt ,' 3r en 022-Voke re #01% 401%. 'ita!, Supporta Up To 84 Conventional 2-+41re Smoke Detectors PasePoit VOME:01412 Gatesw ay Madule Panel Linking Module Panel Linking Modal Cabinet dimensions • 18"H X 14.5"W X 4.3"D Environmental • Storage temp: -10°C to 70°C • Operating temp: 0°C to 50°C • Humidity: 85% RH • EMI: Meets or exceeds the following requirements: - FCC Part 15, Class B Device - FCC Part 68 - IEC EMC Directive Agency Listings Burglary • UL609 Grade A Local Mercantile Premises and Mercantile Safe and Vault • UL611/1610 Grades A, AA, Central Station • UL365 Grades A, AA Police Connect Fire • UL864/NFPA72 Local, Central Station and Remote Station • Factory Mutual • California State Fire Marshal • MEA • UL985 Manual RA steBons -Q 6t40MPs• 1• -QCT 61401MS - Y —0 Tampa &A r —� Raw Satoh" --Q Low Ten, Switch* it' I Isolation/ 4297 Extender Marklee 1 4190£N v-Ptex Two -Zane eg3aida -•.,.-moi iiY YiY i?' Ito (_') ic. 11 .') #j C711111 i Or CJI -- Ot =! ,!I1tI--1 i � Ijf :i' '0 1 Honeywell VISTA -1 28FBP/V1 28FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel SPECIFICATIONS Auxiliary Devices • 6160CR - Red Alpha Keypad • 6139R - Red Alpha Keypad/Annunciator • FSA -8 & FSA -24 annunciator modules • 4204 - Relay Module, four form C contacts • 4204CF - Two supervised output circuits • 5881 Series - RF receiver supporting 5800 wireless detectors • 6220S - System printer used with 4100SM serial module Tvvo-wire smoke detectors conventional • 2100 Series Photoelectric • 2400 Series Photoelectric • 1100 Series Ionization Four -wire smoke detectors conventional • 2112/24 Series Photoelectric • 1412 Series Ionization Horn/Strobes • System Sensor Notification Appliances Manual Pull Stations • 5140MPS-1 + 5140MPS-2 V Plex (addressable) Devices • 4208U Loop Expansion Module - eight zones • 4101SN Single Relay/Zone Module • 4208SNF Class A/B Expander Module • 4209U Group Zoning Module - two/four zones ORDERING VISTA 128FBP Commercial Fire and Partitioned Burglary Alarm Control Panel 12V Model V1281FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel 24V Model • 4190SN Remote Point Module - two zones • 4193SN Two Zone Serial Interface Module • 4293SN One Zone Serial Interface Module • 4297 Isolation/Extender Module V Plex (addressable) Smoke Detectors: • 5192SD • 4192SD • 4192CP • 5192SDT • 4192SDT • 4192CPM • 4192SDTM V-Plex Passive Infrared Detectors • 998MX • 4275EX-SN • 4278EX-SN V Plex (addressable) Contacts • 4939SN-WH • 49448N -WH • 4959SN V-Plex Glassbreak Detectors: • 9500SN VISTA interactive phone module • 4286 Voice Module Optional 24V Power Supply • PS24 - 24V power supply - 3.4A Long Range Radio: • Long Range Radio 7720ULF-XX, 7835C, 7835CF, 7845C Upgraded software • Upgraded Compass Downloader Windows compatible Wireless Devices • 5804BDV - Bi-directional with voice • 5804BD - Bi-directional Key • 5804Watch - Wireless Key & sports watch combined • 5816 - Door/Window Transmitter • 5804 - Wireless key • 5827BD -- Bi-directional Keypad • 5890 - PIR • 5849 - Glassbreak Detector • 5819 - Shock Sensor Commercial Wireless Devices • 5808LST - Wireless Smoke Detector • 5809 - Wireless Heat Detector • 5817C8 - Wireless Commercial Transmitter • 5869 - Hold -Up Transmitter • 5881 ENHC - Commercial Fire/Burg Receiver Access Control • VistaKey V-Plex (addressable) Access Control • VistaKey-SK Starter Kit • VistaKey-EX Expansion Kit • VGM Vista Gateway Module to PassPoint Access Control (Northern Computers) CCTV - VistaView-100 CCTV Switcher or Module Internet Access • Graphical user interface with internet capability • Internet Remote Control - Networking Module • Internet Alarm Communicator (7845i) Paging • VA8201 AlphaNumeric Pager Honeywell Security & Custom Electronics 165 Eileen Way, Syosset, NY 11791 awvw.honeywell.com/security ccVNigh102003 Honeywel Intemalonel hc. 1.N128F6P10 8/04 5193SD/5193SDT V-PLEX® ADDRESSABLE SMOKE DETECTOR Honeywell Honeywell's 5193SD/SDT Addressable Photoelectric Smoke Detector is designed to provide open area protection and to be used with compatible UL -listed Honeywell control panels that support V Plex technology. The detector Incorporates a state-of-the-art optical sensing chamber and an advanced microprocessor. Built-in Drift Compensation algorithms automatically maintain proper operation at factory calibrated detection levels, even when sensitMty is altered due to the presence of contaminates settling into the units chamber. The 5193SDT also features a restorable, built-in, fixed temperature (135° F/57.2° C) thermal detector. FEATURES • Easy Installation: Installation of the 5193SD/SDT detector is simplified by the use of a mounting base that may be pre -wired to the system, allowing the detector to be easily installed or removed for maintenance or service. (See Figure 1). • LED Status Indicators: Two LEDs (green and red) provide local visual indication of the detectors status — including normal operation, alarm, out of sensitivity and trouble conditions. • Test button: This button allows the user to perform periodic testing of the detectors circuitry and verify that the detector is within the sensitivity limits. • Versatile Mounting: Mounting is made simple with the included hardware and the large mounting ports, which accommodate drywall anchors for easy surface mounting. (See Figure 1). • Tamper Protection and Tamper Resistance: The detector contains a built-in tamper switch that can communicate back to the control panel in the event the detector is removed from its base. For an added level of security, the detector also includes a tamper resistant element that prevents removal from the base without the use of tools. (See Figure 1). DIRECT MOUNT HOLES TAMPER RELEASE TAB SNAP OFF TAB FOR TAMPER LOCK Figure 1: Tamper -Resistant Feature/Wiring 5193SD/5193SDT V-PLEX® ADDRESSABLE SMOKE DETECTOR SPECIFICATIONS • Heat Sensor: (Model 5193SDT): 135° F (57.2° C); Flied Temperature Electronic Thermistors • Operating Ambient Temperature Range: 32° to 100° F (0° to 38° C) • Operating Humidity Range: 0 to 95% RH non -condensing • Storage Temperature Range: -4° to 158° F (-20° to 70°C) ACCESSORY (sold separately) • Diameter (including base): 5,3 inches • Height (including base): 2.0 inches • Weight: 6.3 oz. • Agency Listing: UL -268 • System Voltage Range: 7-14V • Standby Current (maximum @ 12V) LED off: 1.2mA LED on: 2.8mA To measure the detector's sensitivity, the SENS-RDR Infrared Sensitivity Reader tool (sold separately) should be used. It reduces testing time, simplifies sensitivity measurements and displays them precisely In terms of percent per foot obscuration. The SENS-RDR eliminates the need for magnets, voltmeters and ladders. ORDERING 5193SD 5193SDT Figure 2: Position of Reader Addressable Photoelectric Smoke Detector Addressable Photoelectric Smoke Detector with Integral Heat Sensor Accessory sold separately: SENS-RDR Handheld Sensitivity Reader Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 www.honeywell.cgm U5103SDT/D May 2009 0 2000Honeywell Internalbnal (no. Honeywell p o Comments As Pe:7f 0 Per The Attach,ed Letter plans have been reviewed by The Tukwila Fire. ntion Bureau for conformancevth current City i)ciards. Acceptance is subject trrors and cr;ssions which do not authorize vfniations of adopted ,Njarcis and ordinances. The responsibility for the ..quacy or design rests totally with the designer. .-ic'•ditions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings kr subsequent approval. Final acceptance is sulgect to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: .0 I ait Ko+ OA 1 I Ey4t,py ufei+1,tv prool kovv,/s-i-voL-e -c4c4`NJQ. riue 3. ho vtay 664, i i -gi‘t /4).64- 4 9,,,10.4. 1,regicc,,Icjt Cr 40Ca,,Li . TUKWILA FIRE DEPARTMENT ?lease call 206-5754407 and give this Fire Pena No. 14-F-1)40 7 -Ad exact addcess for shut- down or restoration approval.