HomeMy WebLinkAboutPP - 18290 ANDOVER PARK WEST - UNIVERSAL FREIGHT FORWARDERS - PERMITS AND PLANS18290 ANDOVER PARK WEST
ASSOCIATED PERMITS
13-5-121
SITE LOCATION
CITY OF TUKWILA
FIRE DEPARTMENT
444 Andover Park East
Tukwila, WA 98188
206-575-4407
Date application
accepted:
FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
King Co. Assessor's Tax No.: 3523049018
Site Address: 18290 ANDOVER PARK WEST 98188 Suite Number: Floor: 1
Tenant Name: UNIVERSAL FREIGHT FORWARDERS New Tenant? ❑- Yes I -No
Property Owner's Name: SEGALE PROPERTIES LLC
Mailing Address: PO BOX 88028 TUKWILA, WA 98138
City State Zip
CONTACT PERSON -if there are questions about the submittal.
Name: JIM THOMAS
CtompanyName: McKINSTRY COMPANY
Mailing Address: 5005 3rd AVENUE SOUTH,
Day Telephone: (206) 763-4819
SEATTLE, WA 98134
E-mail Address: J IMT@MCKI NSTRY.COM
City
State Zip /,
Fax Number: 4.-:"Cip - /(p (r—
Total number of new/relocated devices or sprinkler heads: 10
Valuation of Project (contractor's bid price): $ 4900.00
Scope of Work (please provide detailed information): ADD (10) DRY PENDENT SPRINKLERS
FOR ORDINARY HAZARD OCCUPANCY OF NEW COOLER/FREEZER
PERMIT APPLICATION NOTES
Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING OWNER O AUTHORIZED AGENT:
Signature: yy.� NC4--t
Print Name:
Plan Permit App.doc
Date: 5- d
Day Telephone: (-91,(" /lc' Cift( 9
1/2/13 TFD FP Form 8
SITE LOCATION
Site Address:
CITY OF TUKWILA
FIRE DEPARTMENT
444 Andover Park East
Tukwila, WA 98188
206-575-4407
Date application
accepted:
FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
Tenant Name:
Property Owner's Name: U
Mailing Address:
King Co. Assessor's Tax No.:
Suite Number: Floor:
New Tenant? ❑ - Yes X No
10____A-Nvinf6{f2Kw
CONTACT PERSON -if there are questions about the submittal.
Name: - • 1�
Company Name:
7r' 6(4.) .
City
w4 qg
State Zip
Day Telephone: c r u" -&3-ciefft f
Mailing Address: 5\--025‘ 3/14 Ave 6"• c_ 77fe
401- egw
E-mail Address: e / / S Cram City State Zip
i r YV1 %i� ��tG
Total number of new/relocated devices or sprinkler heads: % 0
Valuation of Project (contractor's bid price): $ `it elOO
Scop of Work (please provide detailed information):
r,2..7„
PERMIT APPLICATION NOTES
Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING OWNER R AUTHORIZED AGENT:
Signature: � 1-(52y1 /,f/k Date:
Print Nam -�-Yy� MI'97/1I A 'S Day Telephone: 906' LiO I
Plan Permit App.doc
1/2/13 TFD FP Form 8
- COOLER ADD\SHOP DRAWINGS-MCKINSTRY\FIRE PROTECTION\FP.DWG, 5/21/2013 10:57:40 AM
\\SEDWGOI\DATA\PROJECTS FIRE TI\DJ\ARCHIVED JOBS\32858 U.F.F. - 18290 ANDOVER W.
F\FRL
TFS
1. SPRINKLER SYSTEM DESIGN PER N.F.P.A. #13
2. ALL MATERIALS SHALL BE NEW AND U.L. LISTED OR F.M. APPROVED
3. FIRE SPRINKLER SYSTEM TO BE INSTALLED, HUNG, BRACED AND
TESTED IN ACCORDANCE WITH N.F.P.A. #13
4. IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT IS THE OWNERS
RESPONSIBILITY TO PROVIDE HEAT THROUGHOUT THE WET PIPE
SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE,
DELUGE AND OTHER TYPES OF VALVES CONTROLLING WATER
SUPPLIES TO SPRINKLER SYSTEMS
5. FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR
THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE
SPRINKLER SYSTEM.
6. ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING OR PATCHING
TO BE BY OTHERS.
7. NEW AND RELOCATED SPRINKLER HEADS ARE TO BE ON 1"
DYNATHREAD OR SCHEDULE 40 ARM OVERS.
8. NEW MAINS AND NEW BRANCH LINES ARE TO MATCH EXISTING PIPE
SIZING WHERE HYDRAULIC CALCULATIONS ARE NOT REQUIRED.
9. SPRINKLER HEADS HAVE BEEN ADDED AND RELOCATED TO
ACCOMMODATE TENANT IMPROVEMENTS. AREAS OUTSIDE SCOPE OF
WORK ARE TO REMAIN.
10. THE OWNER IS RESPONSIBLE FOR THE PERIODIC INSPECTION,
TESTING, AND MAINTENANCE OF THESE FIRE SPRINKLER SYSTEMS IN
ACCORDANCE WITH THE REQUIREMENTS OF NFPA 25 1995 EDITION.
THIS WORK MUST BE DONE BY QUALIFIED PERSONNEL STARTING
AFTER THE WARRANTY PERIOD HAS EXPIRED. THE COMPANY THAT
DESIGNED AND INSTALLED THIS SYSTEM IS THE BEST QUALIFIED TO
PROVIDE THE ONGOING LONG TERM TESTING, SERVICING, AND
MAINTENANCE OF THIS SYSTEM(S).
F W
R
{
1. RELOCATE AND/OR ADD PENDENT SPRINKLERS TO ACCOMMODATE
TENANT IMPROVEMENTS.
2. NEW SPRINKLERS SHALL BE QUICK RESPONSE, STANDARD SPRAY
PENDENT SPRINKLERS RATED AT 155'F AND 5.6k.
3. NEW COOLER DESIGNED TO ORDINARY HAZARD OCCUPANCY.
4. PIPE SIZING MATCHES EXISTING CONDITIONS AND MEETS DESIGN FOR
ORDINARY HAZARD PIPE SCHEDULE SYSTEMS.
5. ALL AREAS OUTSIDE SCOPE OF WORK ARE TO REMAIN AS IS AND
UNAFFECTED BY TENANT IMPROVEMENT.
SDRI\
<LFR
<I- Y
• PENDENT SPRINKLER
O UPRIGHT SPRINKLER
SPECIAL APPLICATION PENDENT SPRINKLER
SPECIAL APPLICATION UPRIGHT SPRINKLER
Q PENDENT AND UPRIGHT SPRINKLER
O CONCEALED SPRINKLER
• EXTENDED COVERAGE CONCEALED SPRINKLER
EXTENDED COVERAGE PENDENT SPRINKLER
SIDEWALL SPRINKLER
DRY SIDEWALL SPRINKLER
DRY PENDENT SPRINKLER
DRY EXTENDED COV. PENDENT SPRINKLER
RELOCATE SPRINKLER
ADD SPRINKLER
,P PLUG OUTLET
a SPRINKLER PIPE CAP
• SPRINKLER PIPE DROP
o SPRINKLER PIPE RISE
EXISTING SPRINKLER PIPING
NEW SPRINKLER PIPING
* SEE SPRINKLER LEGEND FOR SPECIFIC SPRINKLER TYPES *
<1_ DLA\
EXISTING
OFFICES
NOTE: COOLER CEILING HEIGHT IS 11'—O" AFF. MAX STORAGE
HEIGHT ALLOWED IS 9'—O" FOR 18" CLEAR FROM SPRINKLER
DEFLECTORS INSTALLED ON 401 STYLE ESCUTCHEONS.
MECHANICAL UNIT
E—
(TYPICAL)
SSRI\
5'-1"
10'-0"
11 2
7-812
6x2 MECH TEE
C0J
LLI
7-812
C.4
2x1x2 TEE WITH 1"
BALL VALVE AND
PLUG FOR DRAINAGE
<LF R DI- TAILS
10, - 0"
112
9_912
112
9-912
A/C UNIT ON
COOLER ROOF
114
9-10
114
9-10
SPRINKLER SYSTEM
AT ROOF TO
REMAIN AS—IS
r)
1
i 1 SPRINKLER PLAN
FP -1.01 1/4" = 1'-0
00
74)
9-10
1
9-10
Cr)
I
L1J
LiJ
0' 1'
4' 8'
SCALE: 1/4" = 1'-0 U.N.O.
SPRINKLER LEGEND
15'
SYM
TYPE
COLOR
ESC
RESPONSE
TEMP
K
NPT
MFG.
MODEL #
ID #
QTY
0
DRY SSP
CHROME
CHRM 401
QR
155°F
5.6
1/2
TYCO
DS -1
TY3235
10
4P
PLUGGED HEADS
0
TOTAL AFFECTED
10
2x4 SECURED
TO STRUCTURE
STRUCTURE
PIPE TO BE
SUPPORTED
PIPE STRAP
1-5/8" STRUT
MEMBER
HANGER - STRUT
BRANCH LINE
ATTACHMENT
TO STRUCTURE
01
ERISEM I I FRAM
CEILING Tijr 401 STYLE ESC
Hsi!:
1" TEE
✓- DRY BARREL
TYCO DSB-2
"BOOT"
DRY PENDENT HEAD
gJ
DRY SPRINKLER DETAIL
17
Without Comments
O As Noted in Red
• Per The Attached Letter
These plans have been reviewed by The Tukwila Fire
Prevention Bureau for conformance with current City
standards. Acceptance i subject. to errors and
omissions which do not: -.;_< : ;orize voIUions of adopted
Standards and vis } is azo 1 ponsi tiky for the
adequacy of design , r.'._.: of i.. ;i/ >' ih the designer.
Additions, •deleuonF . ?r >>.ei is -+=s i.il:se drawings after
this -date will void thI c;;r1 wi0 require a
• resubmittal of revised ( awl; ,,). for sint approval.
Final acceptance is subject; and Inspection by
The Tukwila Fire Prevention Lui-eau.
Date: 5--)--2 -0 By:
TUKWILA FIRE DEPARTMENT
Please call 206-575-4407 and
give this Fire Permit No.
find exzet address for shut-
down or restoration approval..
PAID
MAY 22 2013
TUKWILA FIRE
�74� 2ero-
instry
FIREPROTECTION
SEATTLE:
5005 3RD AVE SOUTH
SEATTLE, WA. 98124
(206) 762 - 3311
PORTLAND:
12021 NE AIRPORT WAY, SUITE G
PORTLAND, OR 97220
(503) 331 - 0234
PROJECT:
U.F.F.
COOLER
ADDITION
BUILDING A
18290 ANDOVER PARK W.
TUKWILA, WA 98188
REGISTRATION:
1S
REVISIONS:
1 05.21.13 FP ISSUE FOR PERMIT
NO. DATE DESCRIPTION
McKINSTRY DIVISION:
FIRE PROTECTION
DESIGNED BY: JES - 206.763.4812
DRAWN BY: JES
CHECKED BY: JSS
JOB NUMBER:
DATE:
SCALE:
McK # 304611
05/21/2013
1/4" =1'-0" U.N.O.
SHEET TITLE:
U.F.F. COOLER
SPRINKLER PLAN
SHEET NUMBER:
FP -1.01