Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 17770 SOUTHCENTER PKWY - FAMOUS DAVES - PERMITS AND PLANS
17770 SOUTHCENTER PKWY ASSOCIATED PERMITS 07-F-150 07-F-111 07-F-006 06-F-244 91-F-341 07-S-146 96-S-030 92-S-249 889096 PATRIOT FIRE PROTECTION, INC 2707 70th AVENUE, EAST TACOMA,WA 98424 HYDRAULIC CALCULATIONS FOR FAMOUS DAVES CANOPIES FILE NUMBER: 12-9874 DATE: JUN 25, 2007 -DESIGN DATA - OCCUPANCY CLASSIFICATION: DENSITY: AREA OF APPLICATION: COVERAGE PER SPRINKLER: NUMBER OF SPRINKLERS CALCULATED: TOTAL SPRINKLER WATER FLOW REQUIRED: TOTAL WATER REQUIRED (including hose): FLOW AND PRESSURE (@ BOR): SPRINKLER ORIFICE SIZE: ORDINARY HAZARD .15 gpm per sq. ft. 7 sprinklers 256 sq. ft. (max) 7 sprinklers 358.3 gpm 608.3 gpm 358.3 gpm @ 5.6.7 psi K=11.2 NAME OF CONTRACTOR: PATRIOT FIRE PROTECTION INC. DESIGN/LAYOUT BY: CHRIS WILSON AUTHORITY HAVING JURISDICTION: CITY OF TUKWILA CONTRACTOR CERTIFICATION NUMBER: PATRIFP099CF CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 38081321 ) HRS SYSTEMS, INC. TUCKER, GA 30084 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 6/25/2007 T:\HASS\CHRISTIAN\FAMOUS DAVE 1.SDF JOB TITLE: Famous D WATER SUPPLY DAT SOURCE STATI NODE PRESS TAG (PSI) OW AVAIL. TOTAL REQ'D PRESS. @'DEMAND PRESS. PM) (PSI) (GPM) (PSI) CITY 145.0�,,�" 4586.0 143.3 608.3 56.7 Required pressure is44141641 si (60%) less than available pressure. AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 608.3 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 250.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 358.3 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 101 11.0 K=11.20 24.1 55.0 102 11.0 K=11.20 24.1 55.0 103 11.0 K=11.20 25.0 56.0 104 11.0 K-11.20 25.4 56.5 105 11.0 K=11.20 11.5 38.0 106 11.0 K=11.20 13.4 41.0 107 11.0 K=11.20 25.8 56.9 1 11.5 45.3 2 11.5 46.1 3 11.5 46.4 4 11.5 46.6 5 11.5 19.7 6 11.5 47.0 7 11.5 47.7 8 11.5 49.2 9 11.5 51.1 TOR 10.5 51.9 BOR 0.5 - - - - 56.5 CITY 0.0 SOURCE 56.7 358.3 . 1. i SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 6/25/2007 T:\HASS\CHRISTIAN\FAMOUS DAVE 1.SDF JOB TITLE: Famous Dave 1 PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -55.0 1.049 PL 11.25 PF 21.5 101 11.0 11.2 24.1 55.0 20.4 150 FTG 4E2T PE -0.2 1 11.5 0.0 45.3 0.0 0.559 TL 38.45 PV Pipe: 2 -55.0 1.049 PL 12.33 PF 22.1 102 11.0 11.2 24.1 55.0 20.4 150 FTG 4E2T PE -0.2 2 11.5 0.0 46.1 0.0 0.560 TL 39.53 PV Pipe: 3 -56.0 1.049 PL 10.25 PF 21.7 103 11.0 11.2 25.0 56.0 20.8 150 FTG 4E2T PE -0.2 3 11.5 0.0 46.4 0.0 0.578 TL 37.45 PV Pipe: 4 -56.5 1.049 PL 9.25 PF 21.4 104 11.0 11.2 25.4 56.5 21.0 150 FTG 4E2T PE -0.2 4 11.5 0.0 46.6 0.0 0.588 TL 36.45 PV Pipe: 5 -38.0 1.049 PL 10.25 PF 8.4 105 11.0 11.2 11.5 38.0 14.1 150 FTG 4ET PE -0.2 5 11.5 0.0 19.7 0.0 0.282 TL 29.89 PV Pipe: 6 -41.0 1.049 PL 6.50 PF 6.5 106 11.0 11.2 13.4 41.0 15.2 150 FTG 2ET PE -0.2 5 11.5 0.0 19.7 0.0 0.325 TL 20.10 PV Pipe: 7 -56.9 1.049 PL 10.00 PF 22.1 107 11.0 11.2 25.8 56.9 21.1 150 FTG 4E2T PE -0.2 7 11.5 0.0 47.7 0.0 0.595 TL 37.20 PV Pipe: 8 -55.0 2.067 PL 21.00 PF 0.7 1 11.5 0.0 45.3 0.0 5.3 150 FTG 2E PE 0.0 2 11.5 0.0 46.1 0.0 0.021 TL 36.11 PV Pipe: 9 -110.0 2.469 PL 12.00 PF 0.4 2 11.5 0.0 46.1 0.0 7.4 150 FTG ---- PE 0.0 3 11.5 0.0 46.4 0.0 0.031 TL 12.00 PV Pipe: 10 -166.0 3.068 PL 8.00 PF 0.2 3 11.5 0.0 46.4 0.0 7.2 150 FTG ---- PE 0.0 4 11.5 0.0 46.6 0.0 0.023 TL 8.00 PV Pipe: 11 -222.5 3.068 PL 8.50 PF 0.3 4 11.5 0.0 46.6 0.0 9.7 150 FTG ---- PE 0.0 6 11.5 0.0 47.0 0.0 0.040 TL 8.50 PV Pipe: 12 -79.0 1.049 PL 9.83 PF 27.3 5 11.5 0.0 19.7 0.0 29.3 150 FTG 2T PE 0.0 6 11.5 0.0 47.0 0.0 1.093 TL 24.94 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 6/25/2007 ' ` T:\HASS\CHRISTIAN\FAMOUS DAVE 1.SDF JOB TITLE: Famous Dave 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 -301.4 3.548 PL 21.25 PF 0.7 6 11.5 0.0 47.0 O'0�.8 150 FTG ---- PE 0.0 7 11.5 0.0 47.7 0,0 0'034 TL 21.25 PV Pipe: 14 -358'3 3.548 PL 6.00 PF 1.5 7 11.5 0.0 47.7 0.0 11.6 150 FTG T .PQ 0.0 9 2 O O O Q�7 8 11.5 0.0 ' 4 TL 31.69 PV . . . � Pipe: 15 -358.3 4'026 PL 60.00 PF 1.9 8 - I1.5 0.0 49.2 0.0 9.0 150 FTG EPE 0.0 9 11.5 0.0 51.1 0.0 0'026 TL 75'11 PV Pipe: 16 -358.3 6.065 PL 4.50 PF 0.3 9. I1.5 0.0 51.1 0.0 4.0 I50 FTG 2ET PE 0.4 TOR 10.5 0.0 51.9 0.0 0.003 TL 92.14 PV Pipe: 17 -356'3 6.065 PL 10.00 PF 0.3 TOR 10.5 0.0 51'9 0.0 4.0 120 FTG AB PE 4.3 BOB 0.5 0.0 56.5 0.0 0.005 TL 48'00 PV Pipe: 18 -358'3 6.065 PL 0.50 PF 0.0 BOR 0.5 0.0 56.5 0.0 4'0 150 FTG ---- PE 0.2 CITY 0.0 SRCE 56.7 (N/A) 0.003 TL 0.50 PV NOTES: (1) Calculations were performed by the HASS 7.8 computer program under license no. 38081321 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 l2> The system has been calculated to provide an average imbalance at each node of 0'005 gpm and a maximum imbalance at any node of 0'096 gpm. (3) Total pressure at each node is used in balancing the system. (4) PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 6/25/2007 T:\HASS\CHRISTIAN\FAMOUS DAVE 1.SDF JOB TITLE: Famous Dave 1 PAGE: A Diameter (in) 1.049 2.067 2.469 3.068 3.548 4.026 6.065 MATERIAL: S40 HWC: 120 Equivalent Fitting Lengths E T L C B Ell 2.00 5.00 6.00 7.00 8.00 10.00 14.00 Tee LngEll ChkV1v 5.00 2.00 5.00 10.00 3.00 11.00 12.00 4.00 14.00 15.00 5.00 16.00 17.00 5.00 19.00 20.00 6.00 22.00 30.00 9.00 32.00 BfyVly 6.00 6.00 7.00 10.00 11.00 12.00 10.00 in Feet G A D N GatV1v AlmChk DPV1v NPTee 1.00 10.00 10.00 5.00 1.00 10.00 10.00 10.00 1.00 10.00 10.00 12.00 1.00 13.00 13.00 15.00 1.00 14.00 14.00 17.00 2.00 20.00 20.00 20.00. 3.00 28.00 28.00 30.00 DATE: 6/25/2007 SPRINKLER SYSTEM 'HYDRAULIC ANALYSIS Page 6 . T-:\HASS\CHRISTIAN\FAMOUS DAVE 1 SDF JOB TITLE: Famous Dave 1 4586.0 gpm 0 0) a O O N 0 41 ID ON a u r al O W M 0 O CON • 44 TS o) 0 0 cc. .-1 m 40 q 0 W¢� �Q A E.144)``a , WsL u m a O • - a.to .9 y ▪ 1-1 it) aN 0 a. 0 > 4 a g' w0)0) D• 0V; • g N O O N O _ O O N O O O O O co .--I a, x a4 w ---- O O 0 O C' O O N O O o3 W u8 off �� u6 A .uu u W5: _ """:.a & �$: 'h: = u�iO t.i5 = `� C E ed qd d W g� t ti _ S ' ! �PEVII:q P� tltl,]R@o �' I iii_ , III :11 oiliiil , • i 1 I i 1 _ g:-", '� 1 Nye W2 a _ 7 g[ "u E 8 WA APPLETREE CONSTRUCTION FAMOUS DAVES WOSE9NETIBE PVP/ < 9.26Y� tle PP _' �e _. $ d LL ea, •••�.0 .�®�0�+..•.e®06� an .'p1�e�jP B t s..a.v.. ~..... C p�6G6dd Ep� S. •EE .�F 5d d + •: d ( . �] 5!:199 a <§ i�SVEEE Dil.,"a5-'a _ dthhvC .o da.»3.>'0 . r " -r as@i9 �i0ppGggIFF 1 ii _ 21,e Q 1:5 'ia :e! fsoob+ S ONIMdeIa-lv/inNBnS a3SIA3d 1 Y.< � w O oc w 0= fta _;wren a aaa iMsaamaitasaa Ei mogra �sam_I_tae►.. T.I. SPRINKLER PL FLOW TEST SCOPE OF WORK 0 0 is 0 U f 0 GUARDIAN SECURITY LIFE AND PROPERTY PROTECTION >9 -.I-6 y Seattle • Tacoma • Poulsbo • Bellingham FILE MFG. [CONTROL] AES PARKWAY SUPERCENTER FAMOUS DAVE'S PARKWAY SUPERCENTER TUKWILA, WASHINGTON Fire Alarm System Submittal I -Tr) 0 Stet Pitti9 MODEL# 7750-F ACCEPTED Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted stanaeras and oromances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or ,:visions to these drawings atter this date will void thii acceptance and will require a resubmittal of rbvised drawings for subsequent approval. Final acceptance is Subject to fietd test and inspection by The Tukwila Fire Prevention Bureau. Date: (,'-12-°--) By: DESCRIPTION RF SUBSCRIBER UNIT NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testin AI 1743 First Avenue South Seattle, WA 98134 Tel: 206.622.6545 Fax: 206.341.9928 1_52 Tukwila fUKWILA FIRE DEPARTMENT Please call: 575-4407, and give this job No. 07- F - ISD and exact address for shut. 'own or restcration approval. 9'0 1‘9/%—‘--S Fire June 26, 2007 GUARDIAN SECURITY Seattle • Tacoma • Poulsbo • Bellingham FAMOUS DAVE'S 1I-7 South Center Parkway /77-70 Tukwila, WA Fire Alarm System Submittal 1743 First Avenue South Seattle, WA 98134 Tel: 206.622.6545 Fax: 206.341.9928 RJKWILA FIRE DEPARTMkii1, Please call: 575.4407, and give this job No-_ off- E II I end exact address for §rttitt 3 07 r @ 4 Jo S bpt sPt [DRAWING] SILENT KNIGHT 5808 CONTROL PANEL / AES -7750F WIRING DIAGRAM MFG. MODEL# DESCRIPTION [CONTROL] SILENT KNIGHT 5808 AES AES -7750F RF Subscriber Unit Addressable Fire Alarm Control Panel [FIRE ALARM DEVICES] SILENT KNIGHT SD500-ARM Addressable Relay Module [MISCELLANEOUS DEVICES / ITEMS] POWERSONIC PS -1270 12V 7AH Rechargeable Battery PAS MAY -3 2007 Tukwila Fire April 25, 2007 • TECHNICAL DATA: Shelf Life and Storage 100 0 c 80 Ic 0 60 m Ic 'v 40 2. U 0 0 ‘11111111t111111111116.` Charging is r necessary ur 100% of cap s required. Discharge Depth 100% Discharge Depth 50Y Discharge Depth 30% 1. Discharge 2. Charge 3. Ambient Current Current: Temperature: 1 0.2C 0.1C 5°C - ) Charging cher use is ne, to help rece full capacit, 20°C to 25°C (68°F to 77°F) 1 10.2V \\\%,`II\ (°41F `, 1 \\ ` .. Charge may o restore full capactenes n batterieso this state. 9.OV 40°C ( 104°F ) I 30°C _(86°F) 1 Y0°C ( 68°F )--let 1 15-- 20°C Retention Capacity (%) 100 80 60 40 20 0 0 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) Life Characteristics in Stand -By Use of Hess city fore ;fore sary ver fail of ach Ambient Temperature 20'C (68'F) Float Charging Voltage 2.25 - 2.30 V/Cell 120 100 Z 80 m 60 0 c m m tr 40 20 0 1 2 3 Years Life Characteristics in Cyclic Use 4 200 400 600 800 1000 1200 Number of Cycles CHARGING Cycle Applications: Limit initial current to 2.1A. Charge until battery voltage (under charge) reaches 14.40 to 14.70 volts at 68°F (20°C). Hold at 14.40 to 14.70 volts until current drops to approximately 70mA. Battery is fully charged under these conditions, and charger should either be disconnected or switched to "float" voltage. "Float" or "Stand -By" Service: Hold battery across constant volt- age source of 13.50 to 13.80 volts continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. NOTE: Due to the self -discharge characteristics of this type of bat- tery, it is imperative that they be charged after 6-9 months of stor- age, otherwise permanent loss of capacity might occur as a result of sulfation. POLUER%G 11,�oimaioiamoou7" ' (V) 14.0 13.0 p) 12.0 0 11.0 c 10.0 E y 9.0 1- 8.0 Discharge Characteristics PS -1270 Ambient Temperature 20°C (68°F 1.4A A 0 7A -0'35A Final Voltage 7A I I I 14A 1.2 2.4 6 12 24 36 48 1 2 4 6 8 10 20 40 min. X hrs. Discharge Time Discharge Time vs. Discharge Current 20 15 10 5 2 10 5 Discharge Depth 100% Discharge Depth 50Y Discharge Depth 30% 1. Discharge 2. Charge 3. Ambient Current Current: Temperature: 1 0.2C 0.1C (Final Voltage 1.7V/Cell) I \\ 20°C to 25°C (68°F to 77°F) 1 200 400 600 800 1000 1200 Number of Cycles CHARGING Cycle Applications: Limit initial current to 2.1A. Charge until battery voltage (under charge) reaches 14.40 to 14.70 volts at 68°F (20°C). Hold at 14.40 to 14.70 volts until current drops to approximately 70mA. Battery is fully charged under these conditions, and charger should either be disconnected or switched to "float" voltage. "Float" or "Stand -By" Service: Hold battery across constant volt- age source of 13.50 to 13.80 volts continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. NOTE: Due to the self -discharge characteristics of this type of bat- tery, it is imperative that they be charged after 6-9 months of stor- age, otherwise permanent loss of capacity might occur as a result of sulfation. POLUER%G 11,�oimaioiamoou7" ' (V) 14.0 13.0 p) 12.0 0 11.0 c 10.0 E y 9.0 1- 8.0 Discharge Characteristics PS -1270 Ambient Temperature 20°C (68°F 1.4A A 0 7A -0'35A Final Voltage 7A I I I 14A 1.2 2.4 6 12 24 36 48 1 2 4 6 8 10 20 40 min. X hrs. Discharge Time Discharge Time vs. Discharge Current 20 15 10 5 2 10 5 0.35 0.7 1.4 3.5 7 14 Discharge Current (A) Physical Dimensions: in. (mm) Terminals "F1" FASTON 0.187" z 0.032' quick disconnect tabs. (104°F) (68°F) (32°F) IjN "F2" FASTON ( 1- 5.95 (151) Sealed Rocha [table Battery POL!/ER SON/C MODEL PS -1270 F1 12 Volt 7.0 Amo. Mr 0.250" z 0032" quick disconnect tabs. Tolerances are +/- 0.04 in. (+/- 1mm) and +/ 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. FM / NM/MI/NM / / /ff//150Arie SALES & MARKETING 3106 Spring Street Redwood City, CA 94063 USA Tel: 650-364-5001 Fax: 650-366-3662 national-sales@power-sonic.com PRINTED IN U S.A. IS09001-2000 FM39170 www.power-sonic.com CUSTOMER SERVICE 7550 Panasonic Way San Diego, CA 92154 USA Tel: 619-661-2030 Fax: 619-661-3648 customer-service@power-sonic.com 11/04 1M Final Voltage 10.5V \\ 10.2V \\\%,`II\ 9.60V \\ 9.OV \ \ 40°C 20°C • 0°( 8.10V-1 0.35 0.7 1.4 3.5 7 14 Discharge Current (A) Physical Dimensions: in. (mm) Terminals "F1" FASTON 0.187" z 0.032' quick disconnect tabs. (104°F) (68°F) (32°F) IjN "F2" FASTON ( 1- 5.95 (151) Sealed Rocha [table Battery POL!/ER SON/C MODEL PS -1270 F1 12 Volt 7.0 Amo. Mr 0.250" z 0032" quick disconnect tabs. Tolerances are +/- 0.04 in. (+/- 1mm) and +/ 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. FM / NM/MI/NM / / /ff//150Arie SALES & MARKETING 3106 Spring Street Redwood City, CA 94063 USA Tel: 650-364-5001 Fax: 650-366-3662 national-sales@power-sonic.com PRINTED IN U S.A. IS09001-2000 FM39170 www.power-sonic.com CUSTOMER SERVICE 7550 Panasonic Way San Diego, CA 92154 USA Tel: 619-661-2030 Fax: 619-661-3648 customer-service@power-sonic.com 11/04 1M ACCEPTED 0 Without Comments As Noted In Red 0 Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings atter this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: , 5 Z By: SP//0?- 1.1 e e e: •-r-r cEa.-rW- c A-ry N des -ro 3� GonNOL-evev Pawl. eta AcZ ►t4Cf "L=5 -rim Avv2Erh P tiz Dsvtoss to • 'D 'fib Tkp 46' ' It g DDevSS To CENTRAL SnynD 1. /Ll/LUUb Ub:5b PM • 4 d () N'Swj 8 oo s \•sTiNQ inailAtr 4.OD i7A0 r----- -crb---T J i ,i AI FILA L a • 9099 M0�7 1 9 OCR A _ 1 3-1 1 I 111. 1 1-- 1I 11 II 11 1 11 1 11I1I iyi '1 J L_—__i 1 1 11 1 1 L ----' L 1 IL i1I 1 111I kw ..LJ L 1 1- r 1 I D' I 1 1. I -----, r--- r•---1 r ----i 11 o 1 0 11 0 L ---J L ---J 1094 O L 1 L I ev r ---11P iI ir` 1 �1 J .r .t. 41 ©1., om_--voa— �O 74D ---e7.00-- Ct-Ir -QRzi 0 e 1 5`''is`' ycS --vapruT-s ecar.4 A 4 1 So,/ X 24 `1 1 Sty Ct-Ir -QRzi 0 e 1 5`''is`' ycS --vapruT-s ecar.4 A 4 So,/ X 24 `1 1 Sty Received Time Dec. 21. 4:54PM° 4 1 J Page: 3 RIMS DOS 17770 sox e - P PARI TALkAit (AMA 9 mac& 'AM lett Rta-r-40 S) u Ni34 101P - 34b -A30'0 204E- . )`/—c-C`f3 /21/2006 06:55 PM ONIdId .,dDlOVJ I 1 1 D���Dr�lr►—� n �xrrrTi� c < -' 0 C ' 3 1-) ED X)�m DD n -<H �Z-Izo D10 3). ru m G1 � H w mzm MM �r'lntd s. N�Z7 Oz =0rlI-� 0 t�1 --e' m ---I ri -1,- < f' -IH xxv )w )( )(4- 70 --I 3> DZ z- 1Z 1 -VV r I- ti J v) -9 m v) (� (/) _ D (H/) d -0 p f D -13 -1 D zM €y I- x=' ZZ D D Z77 1-1,_._,-.. xi' r' D Z n� 3 --10 ON tdC DDZ O-0 td-ci7C nr- o v) , 7) m [ tyd ��'1 ltd y._, v) V) n -{'U -1 =3> -cm E3 < D N -9 1-- z pfd G1 ---1171 iv) mr'l m m 33VJNf1S JNZ)IDOJ 3H1 D 0 Received Time Dec, 21. 4:54PM Z = Page: 4 M==7C1==Atd(._..Lt� WOU106j05700.(10023 mO mOmOrpOMPUZSD -5212-,27a4* M5Z4� P- 34,,0 NN.NN roo(0cj(0cDOc E ro • (D 3-- 3- (o -q Z fU 1i Q, 3 0 to L8- OA '011!M>1nl s,a/vo.Q C+\ACAD\FS PROG\.TXTFILES\Fariouso!ave Tukwi{loo FSD SYSTEM SELECTION GUIDE UL EX. 3470 ULC CEx747 Page 9-1 7-1-98 REV. 3 I. NOTE: System options do not Cover all conceivable variations. They are listed here as a general guideline to show the most common type arrangement for multiple systems, Based on certain system designs utilizing manifolding, Ron-manifolding, 37nnk systems, ► etc., other tank/cartridge combinations can ,be designed. The combinations below are based on 11 flow, 3.0 gallon tanks arld 5 flow, 1.5 gallon tanks. More competitive designs may be available by utilizing 12 flow and 6 flow systems when ,appropriate. J Total Tank Nitrogen Flow No. Quantity 1 Tvpe of Hardware Cartridge Required 1-5 1 Type of System Single , Single Double 6-11 1 12-16 2 17-22 2 23-27 28-33 3 28-33 (Optional) 34-38 4 39-44 4 45-49 5 50-55 5 56-60 6 Double Multiple Multiple Multiple Multiple 1.5 Gal. Reg: ,Release 3.0 Gal. Reg: Release 1.5 Gal.,Reg. Release 3.0 Gal. Additional Tank 3.0 Gal. Reg. Release 3.0 Gal. Additional Tank 1.5 Gal. Reg. Release 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank 3.0 Gal. Reg. Release 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank 3.0 Gal. Reg. Release (2) 3.0 Gal. Additional Tanks 1.5 Gal. Reg. Release • • 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank Multiple 3.0 Gal. Reg. Release 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank Multiple 1.5 Gal. Reg. Release 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank Multiple 3.0 Gal. Reg. Release 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank Multiple 1.5 Gal. Reg. Release 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank 61-66 6 Multiple 3.0 Gal. Reg. Release 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank - Based on 5 flow numbers for a 1.5al. g system and 11 flow numbers for a 3.0 gal. system. See Pages 4-39 - 4-42 for exceptions. " 8 tanks are manifolded, only a "double tan" nitrogen cartridge (Part No. 73022) can be used. If tanks are manifolded, either an LT -A-101-30 nitrogen cartridge (Part No. 29187) or a double tank cartridge (Part No. 73022) can be used. 41'=20LR (7032) L1 -30-R (5373) Double (73022) . Double (73022) Catbon':Dioxide Cartridge Required 101-10=(15850) 101-20 (17492) 101-30 (15851) 101-30 (15851)- LT:20-R (7032) 101-10 (15850) LT -A-101.30 (29187) 101-30 (15851y - LT -30-R (5373) 101-20 (17492) LT -A-101-30 (29187) 101-30 (15851)"' Double (73022) N/A Double (73022) LT -A-101-30 (29187) Double (73022) LT -A-101-30(29187) LT -20-R (7032) LT -A-101-30 (29187) LT -A-101-30 (29187) LT -30-R (5373) LT -A-101-30 (29187) LT -A-101-30 (29187) Double (73022) LT -A-101-30 (29187) LT -A-101-30 (29187) Double (73022) LT -A-101-30 (29187) LT -A-101-30 (29187) 101-30 (15851) 101-30 (15851)"` 101-30 (15851)- , 101-30 (15a51y** 15851)",101-30(15851y** 101-10 (15850) 101-30 (15851y- 101-30 (15851y- 101-20 (17492) 101-30 (15851)*** 101-30 (15851)"` 101-30 (15851) 101-30 (15851)*** 101-30 (15851)*** 101-30 (15851)** 101-30 (15851)*** 101-30 (15851)*** l ACCEPTED WithotitCamme t$ 121 A Noted In Red p Per The Attached Letter Theseplans have been reviewed by The Tubing Fits Prevention Bureau for conformance with current city standards. Acceptance is subject to errorsand omissions which do not authorize violations of adopted stanoaros and owtnances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings atter this date will void this, acceptance and will require a resubmittal of revised drawings for subsequent mal. Final acceptance is subject to field test and Inspection by The Tukwila Firej)revention Bureau. Date: / I 0- C3 By: Ai" "` C1 1 1 NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in -a Re -inspection Fee and termination of the testing. 1 . 0,4 40 c V .c . 'C{.. -4r+,.1 .S ha't-r ne• Ph OK ; 4pv+r-d` - 1 r 1 .t/t r614 CA -e c -P t.114.1-.•1 �. 3o' 04 co0Q.•%-% i,r tUKWILA FIRE DE-PARTMEM Please call: 575.440 .0°- and give this job No, 0 7— F-oo d axact address for shy awn or restoration approv REMOTE AREA (.15 gpm/sq ft) 7 SIDEWALL SPRINKLERS SYSTEM DEMAND: 358.3 GPM ® 56.7 PSI AT BASE OF RISER VESTIBULE. i1 1-10 BAR SEATING O.FFIC RRY-OUT • 0 O NO WORK THIS AREA v, 0 4-0 4-0iI I WOMEN'S: CO MECH TEE NEW 1/2" ADN. NEW SPRINKLER T.I. SPRINKLER PLAN �- EXIST. OUTLET 1- 0 NEW 1/2" ADN. NEW SPRINKLER TYPICAL NEW DROP DETAIL SCALE: 1"=1'-0" e"N SCALE: 1/8"=1'-O"4 \\\ COOLER/FREEZER .I.C. TRASH ENCLOSURE 112 N.I.0 • VICINITY MAP AREA OF WORK BUILDING KEY PLAN FLOW TEST STATIC RESIDUAL FLOW SOURCE LOCATION 145 PSI 74 PSI 4586 GPM WSR3 170TH & S.C. PKWY 0 tr 1 CCETE Without Comments AsNotedlnRed Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted sstanaaras and orainances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings atter this date will void thie acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: - - 7 By: A -1r" J " TUKWILA FIRE DEPARTMENT. Please call: 575-440Z end give this job a, d exact address for shut• ouwe or restoration arsorornL — c-ewrly u,,;4- 411 ;4(wiS O WSr13 ril4Cw Lek -c- ot44ed -Z .- o7. • GE\EAE \OTES 1. 1 = EXISTING UPRIGHT HEAD LOCATION. 2. = EXISTING UPRIGHT HEAD LOCATION W/ 1" OUTLET. 3. DASHED LINES INDICATE EXISTING PIPE. 4. SEE TYPICAL NEW DROP DETAILS. 5. 0 = 11/2" x 1" MECH TEE U.N.O. 6. = 1" PLUG. SCOPE OF WORK ADD UPRIGHT AND PENDENT SPRINKLERS AS REQUIRED FOR T.I. HANGER LEGEND A "U" HOOK B COACH SCREW ROD D BM. CLAMP W/ "STRAP E EYELET F FLUSH SHELL G CEILING FLANGE H SIDE BEAM BRACKET K SHORT CLIP M ALL THREAD ROD N TOGGLE NUT P POWDER DRIVEN STUD R EXPANSION BOLT S PIPE SPIKE T U V W X Y Z ELCO EZG660 STATE CERTIFICATION SPRINKLER LEGEND I ¢4° �i. 4i � .. -07 SPKR THRDS SPRINKLER ORIFICE SIZES AND TYPE UPRIGHT z o W a TEE SIZE 1 2 5 3 7 1 SPRAY 16 8 16 2 0 01 /2" O 1„ 4 32 SPRAY 1 2 3 7 1 SIDEWALL 8 16 2 < a 1/2" <°. 1, 6(/&[67 1" 2 DRY TYPE O O 1" QO • 1" "'�- TEMP RATING SPRINKLERS UP AND DOWN ' OPENING N x N UP o z 3 2 - WAY EARTHQUAKE BRACE 4 - WAY EARTHQUAKE BRACE 0 165° -o 0 n Q 212° 4 1" TSTRUCTURE TO CENTER LINE OF PIPE IN INCHES Q 2860 ® 1/2" 0 iso° ® 1" FITTING LEGEND ggu 5000 CIO 1/2" P PIPE -O -LET APPROVAL REQUIRED F PLAIN END FIT FITTING SN GROOVED SHAPED NIPPLE CITY OF TUKWILA TSN THREADED SHAPED NIPPLE SPRINKLER HEADS USED SYM MANUF MODEL TYPE THREAD SIZE ORIFICE SIZE HEAD FINISH ESCUTCH FINISH TEMP QTY RELIABLE MODEL G SSP 1/2' K=5.6 CHR CHR 165'F 25 0 RELIABLE MODEL G SSU 1/2' K=5.6 BRZ NA 165T 15 <1 RELIABLE G HSW 1/2" K=5.6 CHR NA 165F 4 CR' TYCO DS -3 DRY HSW ECOH 1' K=11.2 CHR CHR 200'F 7 RELIABLE G SSP 1/2" K=5.6 CHR CHR 212'F 3 TOTAL 54 i QUALITY CONTROL BY JD DATE 06-15-07 APPROVED FOR FABRICATION BY DATE GENERAL NOTES 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL LISTED OR FM APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISERS AND DIMENSIONS SHOWN THUSLY (1-6) WHICH ARE END TO END. 3. EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPUCABLE EDITION 4. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPUCABLE EDITION. 5. PIPING SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPLICABLE EDITION 6. JOINING OF PIPE AND FITTINGS, THREADED & WELDED, SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPLICABLE EDITION. 7. OWNER TO PROVIDE ADEQUATE HEAT IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM TO PREVENT WATER IN PIPES FROM FREEZING. 8. ALL WIRING OF ELECTRICAL DEVICES (IF REQUIRED) TO BE PROVIDED BY OTHERS 9. PAINTING OF PIPE & EQUIPMENT (IF REQUIRED) TO BE PROVIDED BY OTHERS 10. FURRING OF PIPE & EQUIPMENT (IF REQUIRED) TO BE PROVIDED BY OTHERS DESIGN CRITERIA DESIGNED PER NFPA 13 PIPE NOTES 1. ALL THREADED PIPE TO BE BLACK SCH 40 U.N.O. 2. ALL WELLDED/GROOVED PIPE TO BE BLACK SCH 10 U.N.O. REVISIONS NO DATE BY DESCRIPTION 1 6-25-07 CW CHANGE HSW'S FOR ORD. HAZARD SPACING CONTRACT WITH: WA APPLETREE CONSTRUCTION 136 E S TEMPLE SALT LAKE CITY, UTAH JIM CALHOUN 801-556-2559 PROJECT NAME: FAMOUS DAVES SPRINKLER PLAN 17770 SOUTHCENTER PKWY TUKWILA, WA 98188 PATRIFP099CF ChristianW®Patriotfire.OM AT R OT WWW.PATRIOTFIRE.COM FIE NI';'-. 2707 70TH AVENUE EAST TEL: (253) 926-2290 TACOMA, WA 98424 FAX: (253) 922-6150 DESIGNER Chris Wilson SHEET DATE 06-15-07F P I JOB NO. 12-9874 1 OF 1 ,-- DEVICE CONDITION PULLSTATION X INFORMATION X X HEAT DETECTOR X 3 X X SMOKE DETECTOR X X X WATER FLOW SWITCH X 76CD X X TAMPER SWITCH IIWALL � 30CD X GENTEX-GES3-24WR MOUNTING-HIGHT-84'7'0-TDP-AFF X DUCT DETECTOR ADDRESSABLE MODULE' X 9 X KITCHEN HOOD SWITCH SPRINKLER WATERFLOW SWITCH X 1 X LOW BATTERY SPRINKLER TAMPER SWITCH SUPPLIED AND INSTALLED BY SPRINKLER CONTRACTOR X X AC POWER LOSS FIRE ALARM REMOTE ANNUNCIATOR SILENT -KNIGHT -5880 MOUNTING-HIGHT-60"TO-CENTER-AFF X X PHONE LINE 1 OR 2 LOSS FIRE ALARM CONTROL PANEL X X FIRE ALARM SYSTEM MATRIX ON!1_1 OFF 12345 Address 00000 MO LEI 0M000 011000 00 00000 Od�00 2 3 4 5 6 7 0000 100!0 000rl 0 II! 000 00 0 00000 0�0a0 8 9 10 11 12 13 14 15 *Note: Address 0 cannot be used. ADDRESSABLE MODULE ADDRESS SETTINGS AUX POWER 90CD HORN CIRCUIT 2 D D 75CD 90CD HORN CIRCUIT 1 NMI SLC LOOP 30CD \I/ FACP —I ANN SINGLE LINE RISER DIAGRAM SCALE: NTS NOTES: D D 30CD \/ 75CD 75CD 75CD SMOKE pr -4,7K EOL RESISTOR WF SWITCH WATER FLOW 01 TAMPERS 02 PIV TAMPER 03 75CD 75CD 30CD I/ 1 -ALL INITIATING DEVICES TO BE WIRED BY 18 AWG, 2 CONDUCTER WIRE. 2 -ALL SIGNALING DEVICES TO BE WIRED BY 16 AWG, 2 CONDUCTER WIRE. OS&Y TAMPERS PIV TAMPER -4,7K EOL RESISTOR 4.7K EOL RESISTOR SPRINKLER RISER RM WIRING �{ INITIATING APPLIANCE CURCUIT ��-- NOTIFICATION APPLIANCE CURCUIT _-� NOTIFICATION APPLIANCE FEED AND RETURN CIRCUIT 3 -EOL -END OF LINE RESISTORS 4.7K 4 -SD 505AIM MODULES MOUNT ON 4SQ STD BOX, OPEN WIRE AND x DEEP IN CONDUIT 5 -SYSTEM IS CURRENTLY MONITORED BY A STU NEW SYSTEM MUST BE MONITORED BY POINT OR ZONE! < < FIRE ALARM SYSTEM LEGEND > > SYMBOL DESCRIPTION INFORMATION QTY. IDDI DUCT DETECTOR SUPPLIED AND INSTALLED BY MECH. CONTRACTOR 3 OS 01 SMOKE DETETCTOR SILENT KNIGHT SD505APS CEILING MOUNTED WITHIN BFT OF FACP 1 ADDRESSABLE PULLSTATION SILENT KNIGHT SD500PS 8 P 06 76CD WALL MOUNTED HORN STROBE GENTEX-GEC3-24WR MOUNTING-HIGHT-84"7'0-TOP AFF 7 IIWALL � 30CD MOUNTED STROBE LIGHT GENTEX-GES3-24WR MOUNTING-HIGHT-84'7'0-TDP-AFF 3 ADDRESSABLE MODULE' SILENT KNIGHT SD505AIM SPRINKLER/DUCT DET./HOOD SYS INTERFACE 9 0 01 SPRINKLER WATERFLOW SWITCH SUPPLIED AND INSTALLED BY SPRINKLER CONTRACTOR 1 G% SPRINKLER TAMPER SWITCH SUPPLIED AND INSTALLED BY SPRINKLER CONTRACTOR 2 T FIRE ALARM REMOTE ANNUNCIATOR SILENT -KNIGHT -5880 MOUNTING-HIGHT-60"TO-CENTER-AFF 1 ANN FIRE ALARM CONTROL PANEL SILENT -KNIGHT -5808 MOUNTING-HIGHT-60-TO-TOP-AFF 1 FACP WP 75CD i O� 10" WEATHERPROOF BELL WEATHERPROOF STROBE GENTEX-G10-24WR WGEC324-WR 1 1 24WC POWER CIRCUIT $Lc CIRCUIT 11111111111111112,11 ESL 204-12/24V POWER SUPERVISON RELAY TYPICAL DUCT DETECTOR WIRING DIAGRAM SCALE: NTS 0\v\nsi t r EXISTING LANDSCAPING I J Ii 1`06 The wire distance must be less than the maximum per wire gauge. 11 Gauge 22 AWG Max. Distance 1500 ft. 18 AWG 3900 ft. 16 AWG 6200 ft. 14 AWG 10,000 ft. Maximum loop resistance = 50 ohms 4.7K EOL SLC LOOP �.,..! L. OUTDOOR SEATING n- '1' LET 1= \\ G.� EOL HZ# WP 75CD TO FACP OFFICE v EOL 75CD HZ#1 LOBBY/ WAITING CARRY -OUT WP 75CD t 84" TO CENTER AFF MAIN DINING ADJACENT TENANT (NO WORK) KITCHEN MAIN DINING 75CD ✓ATER FLOW PERS IV TAMPER— EXISTING FACP L 41x7 C EXISTING LANDSCAPING TRASH ENCLOSURE 112 60" TO TOP AFF 48" TO PULL LEVER AFF TYPICAL DEVICE MOUNTING HEIGHT SCALE: NTS SLC LOOP ADDRESS 06 4.7K EOL RESISTOR + C N.O. SWITCH DUCT DETECTOR -WATER FLOW -TAMPER AND KITCHEN HOOD WIRING FAMOUS DA VE 'S RESTAURANT �u J c > iithOut C /87 As Noted I (� Per The A TE ments Red ached Letter These plans have been re iewed by The Tukwila Fire Prevention Bureau for conf'rmance with current city standards. Acceptance is ubject to errors and omissions which do not aut orize violations of adopted 'standards and o cinances. The responsibility for the adequacy of design rests totally with the designer. Additions, d;sletions or revi ions to these drawings atter this date will void this acceptance and will require a resubmittal of revised draw ngs for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Preventio Bureau. Lte: 8 -17 -06 B WKWILA FIRE DEPAR MEW Please call: 575-4407 and give this job No. i? c -1=- 2 Y y and exact address for shut. down or restoration aO,)rovaL `1 NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems, Failure of test will result in a Re -inspection Fee and termination of the testing. EXISTING ELECTRIC TRANSFORMER CONTRACT NAME: FAMOUS DA VES jPinn 6#z,441-1-,Latt5Lee'1U/ketal-y TUKWILA WASHINGTON CLOVER CREEK ELECTRIC INC 1413 CENTER STREET TACOMA WASHINGTON (253) 627-6648 ELEC. CONT. # CLOVCE293LA SCALE BOB L 10-13-06 1 OF 1 178"_ DESIGNER DATE SHEET NOV 21 2006 Tukwila Fire CiU n.11a*n w' 1;'100>Y •,,01 y ,a too '00 fel • «,cK es, . ..r x,..-,r,.—,.a- a. -a rw.w ,. i, w.��•wn++r+.+a,...'w� P',41t v "BLT 9 't tvi1^ c-;' Iosv'rsa►El rp MT" v y •••• ••••."•-.• • r ,_ ..._ -,_..,,t • a _,. , -a-- .. .. Vii,: " „ ._ .r.. -«r y w "NJ-.Kl�t;] Yat ..a._. !�J wM.W..N..I410.1',—. ' u.0e,to,44..Y00o-woouMl.u'.r".''+,M-'µ•.-_r..000 Iif f • ZEtriow0.,.?..=1•.O.- SGA ALTi *elkN+wr4wp+ ..,I ,al. t L l t MI MAP., .,, t' ttirS xaaxaTaaat ,aa um • ++'Irr • Arth . #C,► is 74i:"i"i1 L. 5PRIt~.1.ICt. P Q\., , ywu '`' I Q ^T6TAL 1, a • ti 1 44 .;cI o 0 4 0 t! 4 aorawaosawatar x,;.n. /....r..,, n nAoo..,-.«,'Pr ...,,w_..e.n.ren.1�'n.*^'++r'++r*a.n'wr�.,�rMw;p.m,*w.iri ys' 11,11...-..0.01..0.0 .x/ — t; aSMOu 1Fro T ." Ik1STA .1. -- TZ.EMDUG 1./Z 1 Zr/ '.'" Mhr.i w..4 9..FC0►•�+J�L1 we /a• ti CP • Q t ,µ,-.r.7 ,. ,, . (�, 2'..OD I�r.5c - 40 , it ....rt Pi; 11 A rr . -ti, t\1. "-r1-S PS 011,.,1 t7r ,'I $M rte", Or N 0 4 'tl�, N Q+�.l, t.. I ` ?f..(/ +«.�.5�. .� t 3.0 G,i0 a • '4 04 ti CO �, 0 ' to • 0, IA, Ft4 ry• 0, 0 ,00001000.100.,l y,Y4u,yw't100A woo �yw.W,fiN"J.'.m.M.,. II U1t,,ItNU APkA 'y.I '[' . k 5. gE't t t-4, 0. b .1 { 1.i + Yi ...eM •,5�.+ y rvw a„.w i• agar 0100.11.1. 4 ia,,il,,,rya,�y,}.•” 4 '4I -- N 1. x i •w o li 4 r s.-'- w. -- -,..- , . ... ,Mar � ACCEPTED WITHOUT COMMENTS. AS NOTED IN RED [� PER THE ATTAC+-iED LETTER The drawings affixed hereto have been reviewed and accepted by the City of Tukwila Fire Dept. Additions, del Ai pas or revisions to these it , vIngs AP, ;,s date will void thl y a n,Jt ,1 •' Un , require a resubmittal of I c,.I.,o 1 "' Final acceptance is , t5 ` t, ;i ,I ;- inspection by a reeresentattJe t0•,i3 departn-.ent DATE:L? 1 CITY OF TUKWILA 575-440/ 'J S .0221' to ' ' V,LL, TUKWILA FIRE DEPARLVIENT Please call: 575-4401 and give this job No. — and exact address for shut- down or restoration approval. rf-PrE t OCT1992 REVISIONS BY ' 'x .1 41 Dat.M16, : Scat* SlA%\ Q; Drawn , % Job HMO a_MatE l " IiU r ct. 1' No' x.► To /JEW rows 64-i7/4 tlJi‘l.EL f +43 4"; - KESTREL "= KESTREL a.Q PA1!►T NIC✓ 145171 1 I o I EKE kik.) Neal 'P , -r CXTEES O CML) v4a,.. rtc CLk'�tiL� .,ti R6 (I ACCEPTED WITHOUT COMMENTS. ] AS NUTED IN RED ❑ PER THE ATTACHED LETTER The drawings affixed hereto have been rev i awed and accepted by the City of Tu-: vi13 Fire Dept. Additions, deletions or revisions to ties-, ir3,. Ings after this date will void this ;eptanca and will require a resubrni.rai of revised drawings. Final acceptance is subject to field- - inspection by a representative of this department DATE: )/AS -4 BY: SI CITY OF TUKWILA 575-4407 SPRINKLERS UPRIGHT PENDENT O (E'5° Y2'LS,4 s-tob SIDEWALL ,NEW T tr.-rsrAtt.. �' 1 t tr�r►.aE 5L. t1t.?t.)b Writ{ TUKWILA FIRE DEPARTMENT Please call: 575.4407. and give this job No. 9C--03'� and exact address for shuti I down or restoration approval's LiiI OMM'l " FIRE PROTECTION INC. P.O. BOX 1543 WOODINVILLE, WA 98072 (206) 483-5657 JOB: a,A 1117 .. LA -El: BY: zjcj,.. DATE 1--2 -'1 SCALE 5- a A Y9 b OF • AAL .. � , .. ,u� ri n,44 44.4.14,,,, JA,.a. Z... .a ,, �• ErT'; r t g O O O O O C J r1 r=1 —Tr J L r _ L r, I VI E.- 1/ /2 I'- IP-oi! IT f �-L 1-44 -Ir, Cr \JAT I ONJ ' L E-I.E4A 101-1' 6) Protection Serv!cr."-sr;IAtion 13221 S.E. 26t;'I K C,..hVU9 `r]n (2.Z0;."5 Viv , M.]t 644-2.n0 System Dcsigncr Fire Ai47m Conti = Panel hritrtodel E=3 Fire Alarm Annumator Mir Model Bell\Visual Mtr Model Df Horn l_ Mfr Model Q 135° Rate of Rise Mfr Model • 135° Fixed Temp. Mtr __Model ®Smoke Detector Mir Model ®Pull Station Mfr Model Door Holder Mtr Model____ Door Strike Mfr Model Wire type Fi°r- 1 % otsm 1j. TUK W ! L A r - r i lionWma".- 1 . £ t3ack Boxes Used On Al! l: evi•Y� .. C:1,..!, -.1y 'Strap i .. . S :,. 140Th 60 W -OF c7" (a;-,11(v-41,9(- Rex, Oi,11(v-4,9(_Flex. 't' V1}:. y' 4,.4t5p; r7 2 11 501 Caro 111111n111nr.111i111M� 142 14,1 17-7 1-11 b.4 r EQUIPMENT LAN 11 11_011 13 6 WITHOUT COMMENTS. AS NOTED IN RED ❑ PER THE ATTACHED LETTER ACCEPTED The drawings affixed hereto have been reviewed and accepted by the City of Tukwila Fire Dept. Al U_ins, drI °'.ans or revisions to those : !s date will void this require a resubrnia_1 �' P,., M i .1t1;;3. Final acceptance i3 S'! Ti ' i inspection by a re,,dre.yehha_Pjv ..,� department DATEf/,j/'(. BY;IZ... CITY OF 1 5/5.44]x, TUKWILA FIRE DEPARTIvkt T Please call: 575-4407 and give this job and exact address for shut- down or restoration approval. Ef`!� i✓X►`�T. 4Wf3 soF F I— -ro r4ATc 4 WE, F_XI �� 7O'M4, j . \4/GWE Tv Net A -T 50�rtT c/ OLP sE�uiiU Lt NE- 2EMNe. SPKIZ. D126P5 Lf/�� � CCS/G/,(SGS �l,�1/& l�G�N 11� 3 ) 1 i' --J 4-1 • _ 13 1 r. 1 --t r� 7 cs -40 ACCEPaED ►I WITHOUT COM ME' :TS. S NOTED 1.\:R:_ > ❑- PER THE ATTAC.:ED LETTER The drawings affixed hereto linvo been reviewed and accepted by the City of Tukwila Fire Dept. A litions, or revisions to these .:irawmgs a -:t•_-::: is date will void this acco-- t.an,e an ,t,!!!1 require a resubmittal of revised dr:.iwings. Final acceptance is subject to fief - inspection by a representative of this department DATE: jBY: CITY OF TUKWILA 575-4407 re UKWILA FIRE DEPARTMENT se caul: 575.4407 iv this _job address for sht4. eJw+ or restoration approvall..• k•)1