Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 14623 35TH AVE S - KIDKARE DAYCARE LLC - PERMITS AND PLANS
14623 35TH AVE S ASSOCIATED PERMITS 18-F-189 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.:204400001507 Site Address: 14623 35th Ave Tukwila, WA 98188 Suite Number: Floor: Tenant Name: Cascade Academy Property Owner's Name: Islamic Community of BO Mailing Address: 20001 25th Ave NE Shoreline WA 98155 City State Zip 2`17-2t33 Name: Adam Cerdena Day Telephone: 206-763-4177 Company Name: Performance System Integration DBA Fire King of Seattle New Tenant? ❑ - Yes El - No CONTACT PERSON -if there are questions about the submittal. Mailing Address: 240 S. Holden Street Seattle WA 98108 City State Zip E-mail Address: acerdenat_u'�,firekingofseattle.com Fax Number: Contractor's City of Tukwila NICET III number: 129292 Business License number: BUS -0997680 Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ 5,490.00 Scope of Work (please provide detailed information): Replace existing conventional fire alarm panel with new addressable fire alarm panel. Provide permits, submittals, material and install. Panel will use zone module to monitor zones. PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHI AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: V.1 Print Name: l44t6.14.0 rere Day Telephone: Z04 - Z't7 - 2l 33 SP? 20 2018 TUKWILA FIRE Date: `t-Zo --/8 Plan Permit App.doc 8/22/14 TFD FP Form 8 FIRE KING OF SEATTLE /1-f PERFORMANCE SYSTEMS INTEGRATION 240 S. Holden Street Seattle, WA 98108 (206) 763-4177 Phone (206) 763-4269 Fax Fire Alarm System Submittal Guide Cascade Academy 14623 35th Ave Tukwila, WA 98188 tkiz. PAID SE? 20 2018 TUKWjLA FIRE cc aZoL — WILLIAM J. DRIVER III NICET FIRE ALARM SYSTEMS LEVEL IV: 129292 FIND US ON THE WEB AT W W W.FIREKINGOFSEATTLE.COM & W W W.PSINTEGRATED.COM FIRE DETECTION • ACCESS CONTROL • INTRUSION SYSTEMS • CLOSED CIRCUIT TELEVISION NURSE CALL • PAGING & INTERCOM • FIRE EXTINGUISHERS • HYDROSTATIC TESTING OR - CCB#205924... WA - PERFOS*980M4 W�rr Softly d Coamuoictfloo{ Scope of Work To remove the fire alarm zones off of the existing combo panel and putting them on a new addressable Silent Knight 5700 system and utilizing a Silent knight addressable zone module (SK -Zone -6) to monitor the existing zones. "Existing" Zone descriptors are as follows: Zone 1— Upstairs Smoke Detectors Zone 2 — Downstairs Smoke Detectors Zone 3 — Upstairs Heat Detectors Zone 4 — Downstairs Heat Detectors Zone 5- Building Pull -stations. The new Silent Knight panel will activate the existing horn strobe devices utilizing a new addressable control module (SK -Control) to trigger the existing Altronics AL6000L-ADA-Multi-output power supply NAC power supply. FACP in electrical room Cascade Academy Building (below) Operations Matrix OUTPUTS SOUND AND DISPLAY AT BUILDING FACP NAC TRIGGER TO ACTIVATE EXISTING NOTIFICATION DEVICES FACP TRANSMIT ALARM THRU DIALER FACP TRANSMIT TROUBLE THRU DIALER FACP TRANSMIT SUPERVISORY THRU DIALER INPUTS FACP AC POWER LOSS FACP BATTERY POWER LOSS FIRE ALARM SYSTEM OPEN CIRCUIT FIRE ALARM SYSTEM GROUND FAULT FIRE ALARM SYSTEM TROUBLE EXISTING MANUAL PULL STATION EXISTING HEAT DETECTOR NEW SMOKE DETECTOR EXISTING SUPERVISORY SIGNAL (IF USED) EXISTING NAC POWER SUPPLY FAULT Block Diagram — FACP Replacement AREA OF WORK i EXISTING TO REMAIN NOTES (CLASS B SYSTEM): J 2 3 CD DETECTORS (HEAT/SMOKE) INPUT / OUTPUT MODULES MANUAL PULL STATIONS ® HORNS, STROBES, HORN -STROBES... (EOLR AT LAST DEVICE) O 120VAC MAIN POWER FOR THE FIRE ALARM SYSTEM (RE -USE EXISTING). THIS SYSTEM REQUIRES A DEDICATED CIRCUIT THAT IS LABELED FIRE ALARM CIRCUIT" AND IS ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL. ® CIRCUIT BREAKER LOCATIONS) SHALL BE PERMANENTLY NOTED AT ALL FIRE ALARM PANELS O (2) PHONE LINES TO RJ -31 X TELCO BLOCKS (REUSE EXISTING) WITHIN 3' OF FACP ® REPLACE EXISTING DEVICE WITH NEW. REUSE EASING SYSTEM WIRING. Equipment Wiring SK -5700 120 VAC, 60 Hz 115A AC Povor Input WOW Torminal Block 2 Phono Linos On -board Annunciator TI SLC InfOut, 1 NAC/Aux SLC Programming Form C SBUS Trouble Relay Connections Powor Circuits Programming Port l_Pottery Connettor 24 VDC SK -Zone 6 300 COL RESISTOR 011CLUDLO) INTERFACE TWO -WIRE CONVENTIONAL DETECTORS - CLASS B, STYLE B. CONNECT MODULES TO LISTED COMPATITTLE 501.01 0101101. CONTROL PANELS 0011 CLASS 8 MC (TYP1CA1.1 POWER 10 1011 NEXT INTERFACE MODULE MUS1 TTE EXTERNALLY SWITCHED TO RESET THE DETECTORS 00 1001 I RELAY CONTROL NIEVULE 0011 1(11 501.0 10 SWITCH POWER VACUA STANDARD POWER SUPPLY SEE FIGUR 10 FROM ('01101 00 001.0(005 01.5(01? TO NEXT DETPCE 1 POWER LIMN ED 1101401. UNL CIRCUIT ISLC) 30010 MAX AND SUPERWSED LEE PANEL INSTRUCTION MANUAL EOR WIRE HEOUREMENTS SK -Monitor It DETECI ORS MOST 81 LA 0111*0 COMPATMEE WITH THE MODULE WSTALL DETECTORS PER MANUFACTURER-, INSTAL .L01,00 1W3N1UCT,ONY TYPICAL 2 -WIRE INITIATING CIRCUIT CONFIGURATION, NFPA STYLE B OR SECURITY SYSTEMS: NOTE: For UL Listed security installations, the SK -Monitor must be mounted within the control panel enclosure. TO NEXT ""nt DEVICE --.4c (tj (-1 ANY NUMBER OF UL LISTED CONTACT CLOSURE DEVICES MAY BE USED DO NOT MIX FIRE ALARM INTIATING. SUPERVISORY. OR SECURrTY DEVICES ON THE SAME MODULE. 47K EOL RESISTOR ELR-47K MONITOR MODULE 1. To use a common power sup ply between multiple SK -Zone -6 modules. connect a long power supply jumper from T5 or TO to T5 or Tb 011 he adjacent SK Zone -b !nodule C0812 01 STATlie vva,CATOM FROM PANEL OR PREVIOUS DEV:S.E CONNECT MODULES TO LISTED COMPATIBLE CONTROL PANELS ONLY INITIATING DEVICE CIRCUIT )IDC) • NFPA STYLE 13 POWER LIMITED 450pA MAX. V 11 VDC MAX INSTALL CONTACT CLOSURE DEVICES PER MANUFACTURERS INSTALLATION INSTRUCTIONS. _SINALL/NE C7FACUIT ISLC; 32 VDC MAX TWISTED PAIR IS RE COMENDE D ALL WIRING SHOWN IS SUPERVISED AND POWER LIMITED CCM; 1'3 SK -Control TYPICAL NOTIFICATION APPUANCE CIRCUIT CONFIGURATION, NFPA STYLE Y: 24 VOC CIRCUIT DO NOT LOOP WIRE ON TERMINALS 10 & 11 BREAK WIRE RUN TO PROVIDE SUPERVISION OF CONNECTIONS, 24 VDC POWER SUPPLY ISOLATED, REGULATED, POWER LIMITED PER NFPA 70. LISTED FOR FIRE PROTECTION WITH BATTERY BACKUP 47K EOL RESISTOR ELR•47K CONTROL MODULE CONNECT MODULES TO LISTED COMPATIBLE CONTROL PANELS ONLY FROM PANEL OR PREVIOUS DEVICE MODULE POLARITIES ARE SHOWN IN ALARM ,S_Ia_NAL LINT CHCJ1T (SLCj 32 VDC MAX. TWISTED PAIR IS RECOMMENDED UL LISTED EOL RELAY SHOWN ENERGIZED 24 VDC COIL EOLR•1 TO NEXT CONTROL MODULE OR END -OF -LINE RELAY, ONE RELAY ' REQUIRED FOR EACH CIRCUIT. SOME ALJ. WIRING SHOWN IS SUPERVISED CONTROL PANELS HAVE RELAY BUILT AND POWER LIMITED IN AND DO NOT REQUIRE EXTERNAL WIRING. REFER TO PANEL MANUAL. TO NEXT DEVICE 'NOTE: ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT ZONE AND DOES NOT RESULT IN A FAULT IN A SEPARATE ZONE. Equipment Battery Calculations Global Proles Values: Project Name:ICascade Project lD Prepared By:I Date:18/1/2018 Model: 5700 Add. I Volts: 24 VDC 1 Standby Hours:1 Alarm Mins:1 1 Derating Factor:1 Voltage Drop Warning Threshold %.I Max NAC Current: Max Panel Current: t-�.- 1 Panel ID: Location: SILENT KNIGII'I 5700 Calculations Version 10.24.14 Academy 24 1 FK -5418951-18 I 5 E Chiong 1.2 Fire Alarm Control Panel 10 2.5 Amps 2.5 Amps 15700 J 1 Current Draw Wire AWG Ohms Per Ckt.# Circuit Name Qty Alarm & Type 1000 Ft. Length(ft) Actual One -Way Ohms Volts @ p %Drop EOL 5700 5700 CTRL Panel 1 0.200 0.365 =14 Solid V 2.52 150 0.76 19.27 5.56% SK Photo, Photo -T, PhotoR 0.000 0.000 SK Ion 0.000 0.000 SK Heat, Heat -HT, ROR 0.000 0.000 SK Beam, Beam -T 0.000 0.000 SK Duct 0.000 0.000 SK Acclimate 0.000 0.000 SK FIRE -CO 0.000 0.000 SK Control 2 0.001 0.001 SK Control -6 0.000 0.000 SK RelayMon-2 0.000 0.000 SK Monitor, Minirrun 2 0.001 0.001 SK Monitor -2 0.000 0.000 SK Monitor -10 0.000 0.000 SK Pull -SA, PUFDA 0.000 0.000 SK Relay 0.000 0.000 SK Relay -6 0.0000.000 SK Zone 0.000 ,, 0.000 SK Zone -6 1 0.002 0.002 SK Isolator Module 0.000 0.000 B22461 Isolator Base 0.000 0.000 8 Sounder Soder Base 0.000 , 0.000 B200S Inteligent Sounder Base 0.000 , 0.000 B200SR-LF Low Freq Sounder Base 0.000 , 0.000 B200S-LF Low Freq Sounder Base 0.000 0.000 B224RB Relay Base 0.000 0.000 RTS151 Magnetic Remote Test 0.000 0.000 RTS 151 KEY Key Activated Test Remote LED 0.000 0.000 0.000 0.000 RA100Z 5860 5824 LCD Remote Annunc. LCD Remote Annunc. 0.000 0.000 0.000 0.000 5496 Power Expander 0.000 0.000 5895XL Power Expander 0.000 0.000 5865-3 LED Annunciator (3G) 0.000 0.000 5865-4 LED Annunciator (4G) 0.000 0.000 5880 LED Driver Module 0.000 0.000 5883 Relay Module NAC TriggerMtronix Pnt C. 0.000 0.000 0.000 1.500 NAC #1 NAC #2 Notification Appl Circuit cfa. , 0.000 0.000 =12 sora • v 1.59 0.00 20.40 0.00% Total Standby Current (Amps) Standby Time In Hours 0.204 24 1.869 0.083 Total Alarm Current (Amps). Alarm Time In Minutes / 60 (5 Mins) Print Page Total Standby AH Required 4.884 0.156 Total Alarm AH Required Total Combined AH Required 5.04 Command Shortcuts 1 Configure Circuits 1 Multiply By The Derating Factor 1.20 Minimum Battery AmpHours Required 6.05 Equipment List Manufacturer Device Description Silent Knight SK 5700 FACP Silent Knight SK -Zone 6 Zone Interface Module Silent Knight SK -Monitor Monitor Module Silent Knight SK -Control Notification Module Werker WKAl2-7.5F 12V 7.5Ah Sealed Lead Acid Battery SILENT KNIGHT by Honeywell INTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight® Model 5700 Single Loop Addressable Fire Alarm Control System The affordable addressable fire alarm control panel solution. IntelliKnight Model 5700 is a class leading single loop addressable fire alarm control/communicator system. 5700 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built-in digital communication, distributed intelligent power, that includes an easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description The basic IntelliKnight 5700 system can be enhanced by adding modules such as 5860 remote annunciator, 5824 serial/parallel printer interface module (for printing system reports), and 5496 intelligent power module. 5700 supports SD or SK devices. 5700 also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features • Built-in support for up to 50 SK detectors and 50 SK modules creating a total point capacity of 100 points • Built in support for up to 50 SD devices • Up to 125 zones and 125 output groups • Uses standard wire—no shielded or twisted pair required • Built-in digital communicator • Central station reporting by point or by zone • Supports Class B (Style 4) and Class A (Style 6 or 7) configuration for SLC • Drift compensation • 13 pre-programmed output cadences (including ANSI - 3.41) and 4 programmable outputs • Notification circuits configurable as 1 Class A (Style Z) or 2 Class B (Style Y), or auxiliary power for resettable, constant, or door holder power • Built-in synchronization for AMSECO, Gentex®, Faraday, System Sensor® and Wheelock® appliances • Built-in annunciator with 80 -character LCD display • RS -485 bus provides communication to system accessories • Upload or download programming, event history, or detector status onsite or from a remote location using a PC and 5660 Silent Knight Software Suite (SKSS) • Two built-in Form C programmable relays rated at 2.5A at 27.4 VDC SILENT KNIGHT )IntelliKnight�=> Model 5700 • Improvements in SKSS deliver five times faster upload/downloads • Built-in RS -232 interface for programming via PC • Built-in Form C trouble relay rated at 2.5A at 27.4 VDC • Programmable date setting for Daylight Saving Time Compatibility The 5700 signal line circuit (SLC) supports multiple device types of the same protocol: • SK • SD You cannot mix SD and SK SLC devices on a FACP. P/N 350392 Rev M © 2014 Honeywell International Inc. INTELtIKNIGHT FIRE ALARM CONTROL PANEL Model 5700 Fire Alarm Control Panel Specifications Electrical Primary AC: 120 VAC, 60 Hz, 1.5A Total Accessory Load: 2.5A @ 27.4 VDC Notification Power: 2.5A @ 27.4 VDC, power -limited Standby Current: 200 mA Alarm Current: 365 mA Notification/Aux Power Circuits: 2.5A @ 27.4 VDC per circuit, power -limited Battery Charging Capacity: 7.0-35.0 AH Battery Size: 7 AH max. allowed in FACP cabinet. Larger capacity batteries can be housed in an RBB accessory cabinet. Physical Dimensions: 12.75" W x 15.2" H x 3.4" D (32.39 W x 38.42 H x 8.57 D cm) Weight: 11.5 lbs. (5.2 kg) Color: Red Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required) Listings NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non -coded) signalling services. Other Approvals: UL Listed; CSFM 7170-0559: 144; MEA 429-92-E Vol. XVI; OSHPD (CA) OSP-0065-10 S -BUS Accessories 5860/R Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighter's key switch as the 5700. The system can be fully programmed and operated from any 5860. 5860 is gray and 5860R is red. 5496 Intelligent Power Module A 6 amp notification power expander that provides four additional power -limited notification appliance circuit outputs. 5880 LED/IO Module Features 40 LED outputs, 8 normally open dry contact inputs and one piezo output. 5865-3 and 5865-4 Remote LED Annunciator Features 30 Programmable LED (15 red and 15 yellow) outputs and a piezo sounder. The 5865-4 adds a silence and reset switch to the package. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. 5824 Serial/Parallel Printer Interface Module Provides one parallel and one RS -232 serial port for connecting a printer to 5808. Use to print a real-time log of system events, detector status reports, and event history. Interfaces with building control system. Miscellaneous Accessories 5660 Silent Knight Software Suite User-friendly Windows software for remote programming of 5700s using a PC. Upload and view panel account information, event history, and detector status. 5670 Silent Knight Software Suite End-user facility management software allows viewing of detector status and event history via modem or direct connection. RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406 mm W x 254 mm H x 152 mm D SK -SCK Seismic Compliance Kit. SD505-DTS-K Remote test switch that provides remote key operated test function and annunciation of detector alarm with SD505-DUCTR. SP -TR Small panel trim ring. Use to flush mount the panel. 16.975' H x 14.630" W. SD and SK Devices See the data sheets listed below for a complete listing of the SD and SK devices. 53624 SD Devices data sheet 53623 SK Devices data sheet SILENT KNIGHT by Honeywell This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com Assembled In America INTELLIKNIGHT ACCESSORY SILENT KNIGHT by Honeywell S K -Zone -6 Six Zone Interface Module The SK -Zone -6 is an addressable zone interface module for use with IntelliKnight series fire alarm control panels (FACPs). The SK -Zone -6 provides six zone inputs that allow a Silent Knight FACP to interface and monitor two - wire conventional smoke detectors. This means you can retrofit an existing building and use existing conventional devices. Now there's even more power and flexibility available to the IntelliKnight family of products! Description The inputs on the SK -Zone -6 share a common FACP signaling line circuit (SLC) input, and the initiating device circuits share a common external power supply. Otherwise, each input on the module operates independently from the others. If needed, you can disable a maximum of two unused inputs on the SK -Zone -6 board. It transmits the status of a zone of two -wire detectors to the FACP. Status conditions are reported as normal, open, or alarm. The SK -Zone -6 supervises the zone of detectors and the connection of the external power supply. All two -wire detectors being monitored must be UL compatible with the SK -Zone -6. Features • Converts a conventional two -wire loop to an SLC loop • Six zone inputs • Fully supervised • Support for Class B and Class A wiring • Removable 12 to 18 AWG plug-in terminal blocks • Individual LED for each relay contact • Two module mounting in the IDP-ACB cabinet • Up to two unused modules can be disabled • Rotary address switches for fast installation • Mounting hardware included • UL Listed Specifications Physical Height: 6.8"H x 5.8" W x 1.0"D Shipping Weight: 6.3 oz (196 g) Environmental Operating Temperature: 32°F — 120°F (0°C — 49°C) Humidity: 10% — 93% non -condensing SK -Zone -6 Electrical Operating Voltage: 15 — 32 VDC SLC Standby & Alarm Current: 2 mA max SLC Loop Resistance: 4052 max. Initiating Device Circuit: Supervised, power - limited Max. IDC Wiring Resistance: 2552 max External Power Supply Standby Current: 50 mA Alarm Current: 70 mA per module End -of -Line Resistance: 3.9k S2 Compatibility The SK -Zone -6 is compatible with the following IntelliKnight FACP's: 5700 5808 5820XL 5820XL-EVS For a list of detectors compatible with the SK -Zone -6, see the SK -Zone -6 Installation Instruction (PN 156-3441-000) P/N 350130 Rev D © 2015 Honeywell International Inc. INTEL`LIKNIGHT ACCESSORY Model SK -Zone -6 Addressable Two -Wire Interface Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, SK -Zone -6. All two -wire detectors being monitored shall be UL listed compatible with the SK -Zone -6. 3,9K EOL - + + + Resistor To Use a Common Power Supply Between Multiple SK -Zone -6 Modules, You Must Jumper Adjacent SK -Zone -6 Modules as Shown in the Installation Instructions Detectors Must Be UL Listed Compatible with Module 24 VDC External + 4 Power Supply 4 From Compatible FACP + or Previous Device — To Next Device SLC Wiring the SK -Zone -6 Two -Wire Interface Module and Two -Wire Conventional Detectors for Class B, Style B O To Use a Common Power Supply Between Multiple SK -Zone -6 Modules, You Must Jumper Adjacent SK -Zone -6 Modules as Shown in the Installation Instructions Detectors Must Be UL Listed Compatible with Module 24 VDC External + 4 Power Supply 4 From Compatible FACP + 4 or Previous Device — 1 To Next Device SLC Wiring the SK -Zone -6 Two -Wire Interface Module and Two -Wire Conventional Detectors for Class A, Style D O a O D O D OD O D Installation The SK -Zone -6 mounts in the Silent Knight IDP-ACB cabinet. The IDP-ACB has a built in chassis that will accommodate one or two SK -Zone -6 modules. Ordering Information SK -Zone -6 Six Zone Two -Wire Interface Module Accessories IDP-ACB SK Module Cabinet. Cabinet holds two SK -Zone -6 SILENT KNIGHT by Honeywell This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: 203-484-7161 Fax: 203-484-7118. For Technrcal Support, Please call 800-446-6444. www.silentknight.com Assembled in USA t INTELLIKNIGHT ACCESSORY SILENT KNIGHT by Honeywell SK -Monitor Intelligent Monitor Module The SK -Monitor module provides an interface to contact devices, such as security contacts, waterflow switches, or pull stations. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK -Monitor is an addressable monitor module for use with Silent Knight IntelliKnight series fire alarm control panels (FACPs). The SK -Monitor is intended for use in intelligent, two -wire systems, where individual address of each module is selected using the built-in rotary switches. The SK -Monitor supports Class A supervised or Class B supervised wiring to the load device. Conventional 4 -wire smoke detectors can be monitored for alarm and trouble conditions. Features • Single contact monitor • Support for Class A and Class B wiring • Fully supervised • Panel controlled status LED that flashes green in normal state and is solid red in alarm • Attractive ivory cover plate • Rotary address switches for fast installation • SEMS screws for easy wiring • UL Listed Installation The SK -Monitor mounts directly into a 4" square electrical box. The box must have a minimum depth of 2-1/8". A surface mount electrical box (System Sensor® PN SMB500) is available from Silent Knight. Compatibility The SK -Monitor is compatible with the following IntelliKnight FACP's: 5700 5808 5820XL 5820XL-EVS SK -Monitor Specifications Physical Height: 4.5" (11.4 cm) Width: 4" (10.2 cm) Depth: 1.25" (3 cm) Shipping Weight: 6.3 oz (196 g) Electrical Operating Voltage: 15 — 32 VDC Current Draw (LED on): 5.0 mA max Operating Current (LED flashing): 375 pA INTECLIKNIGHT ACCESSORY Model SK -Monitor Intelligent Monitor Module TO NEXT -10—(L9- C€VICE .,R c �`—�C �7��" { AN( NUMBER CF U. USTEC CLWTACT CLOSURE. DEVICES MAY BE USED. D3 MDT MX FIRE ALAFAI INTIATNG, SLFERMEORY, OR SECURITY DE'i10ES. ONTI E S4WE MJDLLE. 47K EOL RESISTOR EI.FI.47K MONITOR P.4 ULE !VITIATING CEO:1E CFTCUIT (IDC) - NFPA STYLE. B POWER UPOITED:4.54.M MAX. 4d 11 VDC WAJC INSTALL CONTACT CLOEiFE DEVICES PER WANLFACTUFEFTS INSTALLATION NSTPJCT1CN9. 2 -Wire Initiating Circuit Configuration, NFPA Style B FFr4riR4NELOR FRE'rr1OUs DEw10E CONNECT tiM:OLLESTO Lt9TED CCM MIME CONTROL FANELE ONLY SIGNAL LINE CIRCUIT SLG] 32' VC MAX TV%1STEO PAIR L9 FECO mei DE 0 ALL WFIIMG SHOWN 198LFEFMEEDAND POWER LIMITED TO NEXT < H DEVICE ,rt (•1 ANY NUMBER OF UL LISTED CONTACT CLOSURE DEVICES MAY BE USED DO NOT MIX FIRE ALARM INTIATING, SUPERVISORY. OR SECURITY DEVICES ON THE SAME MODULE. EOL RESISTOR IS INTERNAL AT TERMINALS 9 & 9 MONITOR MODULE n n 10; ree n Yr Ts INSTALL CONTACT CLOSURE DEVICES PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. LJ LJ FROM PANEL OR t'!t PREVIOUS DEVICE CONNECT MODULES TO LISTED COMPATIBLE NOTIFIER CONTROL PANELS ONLY SIGNAL LIN ECJLECU1L SLC) S2 VDC MAX. SHIELDED -TWISTED PAIR IS RECOMENDED ALL WIRING SHOWN IS SUPERVISED AND POWER LIMITED 4 -Wire Initiating Circuit Configuration, NFPA Style D Standby Current: 400 pA max @ 24 VDC (one communication every 5 sec with 47K EOL) 550 pA max @ 24 VDC (one communication every 5 sec with EOL <1 K) 5.5 mA (with LED latched on) LED Current: 5.5 mA (with LED latched on)End-of-Line Resistance: 47K S2 Initiating Device Circuit Wiring Resistance: 1,500 S2 max SLC Loop Resistance: 40 S2 max. Environmental Operating Temperature: 32°F — 120°F (0°C — 49°C) Humidity: 10% — 93% non -condensing Ordering Information SK -Monitor Monitoring Module Accessories SMB500 4" Square Surface Mount Electrical Box SILENT KNIGHT by Honeywell This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 8200-446-6444. www.silentknight.com MADE IN AMERICA FORM# 350131 Rev D © 2013 Honeywell International Inc. SILENT KNIGHT by Honeywell INTELLIKNIGHT ACCESSO SK -Control Intelligent Notification Module The SK -Control gives you the flexibility to add notification circuits wherever they are needed on an IntelliKnight FACP signaling line circuit (SLC) loop. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK -Control is an addressable notification module for use with Silent Knight IntelliKnight series fire alarm control panels (FACPs). The SK -Control provides supervised monitoring of wiring to load devices that require an external power supply to operate, such as bells, horns, and strobes. It is capable of Class B (Styles Y) and Class A (Style Z) supervision. Upon command from the FACP, the SK -Control will disconnect the supervision and connect the external power supply across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned on. The external power supply is always relay isolated from the SLC loop, so that a trouble condition on the power supply will never interfere with the rest of the system. Features • Flexible solution for adding notification circuits where needed • Support for Class B (style Y) or Class A (style Z) wiring • Panel controlled status LED that flashes green in normal state and is solid red in alarm • Polling LED visible through the cover plate • Attractive ivory cover plate • Rotary address switches for fast installation • SEMS screws for easy wiring • UL Listed SK -Control Installation The SK -Control mounts directly into a 4" square electrical box. The box must have a minimum depth of 2-1/8". A surface mount electrical box (System Sensor® PN SMB500) is available from Silent Knight. Compatibility The SK -Control is compatible with the following IntelliKnight FACP's: • 5700 • 5808 • 5820XL • 5820XL-EVS INTELLIKNIGHT ACCESSORY Model SK -Control Intelligent Notification Module 47K EOL RESISTOR ELR-47K Notification Appliance Circuit NFPA Style Y MODULE POLARITIES ARE SHOWN IN ALARM (-)�(-) (-) TO NEXT CONTROL MODULE OR END -OF -LINE RELAY. ONE RELAY REQUIRED FOR EACH CIRCUIT. Notification Appliance Circuit NFPA Style Z MODULE POLARITIES ARE SHOWN IN ALARM U TO NEXT CONTROL MODULE OR END -OF -LINE RELAY. ONE RELAY REQUIRED FOR EACH CIRCUIT. FROM PANEL OR PREVIOUS DEVICE (+) 111.TO NEXT DEVICE (+) FROM PANEL OR PREVIOUS DEVICE TO NEXT DEVICE Specifications Physical Height: 4.5" (11.4 cm) Width: 4" (10.2 cm) Depth: 1.3" (3.2 cm) Shipping Weight: 6.3 oz (196 g) Environmental Operating Temperature: 32°F — 120°F (0°C — 49°C) Humidity: 10% — 93% non -condensing Electrical Operating Voltage: 15 — 32 VDC Current Draw: 6.5 mA max (LED on) Operating Current: 375 pA average (LED flashing) Drain on External Power Supply: 1.7 mA max (using internal EOL relay) End -of -Line Resistance: 47K S2 Standby Current 400pA max @ 24 VDC (one communication every 5 sec with 47K EOL) 550pA max @ 24 VDC (one communication every 5 sec with EOL <1 K) LED Current: 5.5 mA (with LED latched on) SLC Loop Resistance: 4052 max. Accessories SMB500 SILENT KNIGHT by Honeywell This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com MADE IN AMERICA FORM# 350125 Rev C © 2013 Honeywell International Inc. '7)1 BATTERIES Werker SLA technology offers high-density power that out -performs traditional lead acid batteries. The Absorbed Glass Mat (AGM) construction is designed for efficient gas recombination and allows for maintenance -free operation. Werker SLA batteries maintain their high capacity with a design that is resistant to damage caused by deep discharge. Every Werker SLA battery is inspected to ensure the highest standards in materials and fabrication. Battery Features: • Werker SLA AGM batteries contain a proprietary grid alloy formula. This formula combined with the advanced plate curing techniques offer improved performance. • Werker batteries contain a unique electrolyte formula with a special sub -colloid additive for higher reliability and longer life. • More than 1,0D0 discharge/recharge cycles. • The unique construction and sealing techniques of the Werker battery guarantee leak -proof operation. • Heavy-duty lead calcium tin alloy grids provide an extra margin of performance and service life in cyclic applications, even after repeated over -discharges. • Quality Assurance Engineers monitor and control the entire production process. Charger Features: New! SLA Chargers • Regulated trickle charge for "float" mode charging • Short circuit protected • Reverse polarity protected • Thermal protection in case of overload • Alligator clips • Color LED to indicate state of charger TTerer: xso 9001 SLA/AGM BATTERIES Item # Flame Capacity Dimensions Height Over Weight Flame Capacity Dimensions Height Over Weight Volts Retardant Ah L x W x H (in.) Terminal lin.) (lbs.) Item # Volts Retardant Ah L x W x H (in.) Temiinal (in.) (lbs.) WKA1 2-0.8W . 12 0.8 3.78 x 0.98 x 2..40 2.4 0.8 WKAl2-7,5F2 12 - 7.5 5.94 x 2.56 x 3.74 3.98 6.0 WKA 12-1.3F 12 - 1 3 3.82 x 1.69 x 2.05 2.28 1.4 y;(1 12,,; 2 F 2 12 - 12 5.94 x 3.90 x 3.74 3.98 9.3 WKAl2-2ST 12 - 2 5.91x0.79x3.54 3.54 1.7 WKAl2_18NBL 12 - 18 7.13 x 3.03 x 6.57 6.57 13.9 WKAl2-2.3F 12 - 2.3 6.97 x 1.38 x 2.40 2.64 2.0 WKAl2-26N8 12 - 26 6.50 x 6.93 x 4.92 4.92 20.3 WKAl2-3.3F 12 - 3.2 5.28 x 2.64 x 2.40 2.64 3.2 WK"',12-33C 12 - 35 7.72 x 5.16 x 6.10 6.57 25.4 WKA 12.5._A. 12 - 4.5 5.51 x 1.89 x 3.98 4.21 4.4 WKAl2-33J 12 - 35 7.72 x 5.16 x6.10 7.09 25 4 WKAI 2 FF 12 - 5 3.54 x 2.76 x 3.98 4.21 4.0 Y . 2 14gFR. 12 Y 45 7.80 x 6.54 x 6.85 6.85 35.7 WKAl2-7.5F 12 - 7.5 5.94 x 2.56 x 3.74 3.98 6.0 WKA1255C3R 12 Y 60 9.02 x 5.43 x 8.19 8.35 40.3 Continued on Next Page For more information please contact: Re . lacententUnbatte, y ogAerd www.ReplacementUPSbattery.com Phone: 952-217-6611 Email: info@replacementupsbatterycom Continued from Previous Page Page 2 SLA/AGM BATTERIES Item N Volts WKAl2-55P/FR 12 WKAl2.80C/FR 12 WKAl2-80J/FR 12 WKAl2-100C/FR 12 WKAl2.100J/1-R 12 WKAl2-125C1FR 12 WKA6-1.3F 6 WKA6-3.3F 6 WKA6.5F 6 WKA6-5SP 6 WKA6 7.2F 6 WKA6.8.2F 6 WKA6-10F 6 WKA6-12F 6 Flame Retardant Y Y Y Y Y Y Capacity Ah 60 80 80 100 100 140 1.3 32 5 5 7.2 8.2 10 12 Dimensions LxWxH(in.) 9.02x5.43x8.19 10.24 x 6.65 x 8.31 10.24 x 6.65 x 8.31 12.09 x 6.65 x 8.31 12.09x6.65x831 13.43 x 6.81 x 11.06 3.82 x 0.94 x 2.05 5.28 x 1.34 x 2.40 2.76 x 1.85 x 3.98 2.64x2.64x3.82 5.94 x 1.34 x 3.74 3.90 x 2.24 x 4.53 5.94 x 1,97 x 3.74 5.94 x 1.97 x 3.74 Height Over Terminal (in.) 9.06 8.46 9.06 8.46 9.06 11.3 2.28 2.64 4.21 4.53 3.98 4.53 3.98 3.98 Weight (lbs.) 40.3 55.1 55.1 72.8 72.8 104.7 0.7 1.6 2.1 2.0 3.0 3.8 4.4 4.6 WKA6.12F2 6 - 12 5.94 x 1.97 x 3.74 3.98 4.6 Item N WKA6.14A WKA6-14T1 Flame Capacity Dimensions Height Oyer Weight Volts Retardant Ah 1. x W x H (in.) Terminal (in.) (lbs.) 6 - 14 4,25 x 2.80 x 5.51 6 - 14 4.25 x 2.80 x 5.51 5.51 6.2 5.51 6.2 WKA6.1412 6 - 14 4.25 x 2.80 x 5.51 5.51 6.2 WKA6-14T3 6 - 14 4.25 x 2.80 x 5.51 5.51 6.2 WKA6-42F2 6 42 6.3E x3.46 x6.42 6.69 15.9 WKA6-42N8 6 WKA4-0 5F2 4 - 42 6.38 x 3.46 x 6.42 - 4.5 1.85 x 1,85 x 3.98 6.85 15.9 4.21 13 WEAKER SLA CHARGERS Item N WK6V500 Volts 6V mA 500mA Dimensions LxWxH(in.) 2.36 x 2.04 x .73 Weight (lbs.) 0.58 Wk12V500 12V 500mA 2.36x204x 73 0.66 WKSV1000 6V WK12V1000 12V 1000mA 1000mA 2.54 x 2.32 x 1.95 0.86 2.54 x2.32x195 150 ACCEPTED Without Comments o As Noted in Red O Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City . randards. Acceptance is subject to errors and nissions which or; not authorize violations of adopted 7ndards and ordinances. The responsibility for the dequacy of design. ,,ests totally with the designer. additions, deletions of revisions to these drawings after this date will void this acceptance and will require a resubmittai of revised drawings for subsequent approval. Final acceptance is subject to field test and Inspection by The Tukwila Are Prevention Bureau. Date: /0-3 �� By: 43.11 sl ( /um, gddrosg4 ii4/ 04" 11,;'L,A,4'i,` hoz.,,, qt rove -A br e 4 Ntar-s h4 1, TUKWILA FIRE DEPARTMENT "'tease call 206-575-4407 and jive this Fire Permit No. /1-F- mnd exact address for shut- -own hut°own or restoration approval.