Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 15708 39TH PL S - CIELO APARTMENTS BLDG D - PERMITS AND PLANS
15708 39TH PL S ASSOCIATED PERMITS 19-F-218 441tiuir444 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 8108600960 Site Address: 15708 39th PI S., Tukwila, WA 98188 Suite Number: Floor: 3 Tenant Name: Cielo Apartments - Building D New Tenant? ❑ - Yes 0 - No Property Owner's Name: CH Tukwila LLC, Cumberland Holdings, LLC Mailing Address: 904 Silover Srprings Rd #224 Rolling Hills Estates CA 90274 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Thomas (Tommy) Pennington Day Telephone: (360) 252-1505 Company Name: SCSS/DBA: Fire & Security (Alarmcenter Inc) Mailing Address: 4500 3rd Ave SE, Suite #1 Lacey WA 98503 City State Zip E-mail Address: thomas.pennington@sbdinc.com x Number: Contractor's City OF fa Tukwila (360)438-4244 NICET III number: 144348 BusinessLicensenumber: ALARMC*820J0 (UBI#602404981) Total number of new/relocated devices or sprinkler heads: / Valuation of Project (contractor's bid price): $ 43,526.60 Scope of Work (please provide detailed information): Installing new FACP, AES, Monitoring and Notification devices to each apartment building. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT T HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: /9, Date: Sept. 27, 2019 Print Name: Thomas (Tommy) Pennington Day Telephone: (360) 252-1505 or (360)485-2594 Plan Permit App.doc 8/22/14 TFD FP Form 8 Horn Tones and Sound Output Data vigargoalrwrltzr,'n,, Mathew Buntin NICET #144348 Fire Alarm Systems Level 111 SEQUENCE Of OPERATIONS CD 0 cZ 1-- > Cn ,,,,trorrarr Amuitametnalt: scol. Switch Position Sound Pattern dB 1 2 AUDIBLE VISUAL ALARM I NDICATION @ FACP 0 3 ACTIVATE. NOTIFICATION DEVICES 0 0 ACTIVATE WATEFLOW BELL TRANSMIT SIGNAL TO CENTRAL STATION 0 Temporal Temporal Temporal 4 Non -Temporal 5 Non -Temporal 6 Non -Temporal 7t Coded High 8-17.5 16-33 24 -Volt Nominal Volts Volts Reverberant Anechoic DC FWR DC FWR DC FWR DC FWR 78 78 84 84 88 88 99 98 Medium 74 74 80 80 86 86 96 96 Low 71 73 76 76 High 82 82 88 88 Medium 78 78 85 85 Low High 8t Coded 75 75 81 81 82 82 88 88 93 92 100 100 90 90 98 98 88 84 96 92 93 92 101 101 Medium 78 78 85 85 90 90 97 98 PARCEL #: AREA: TYPE OF CONST: OCCUPANCY: I 5708 39th PLACL S. TUKWILA , WA 96 88 81 0860-0960 23,053 FT2 WOOD FRAME N/A WI E LEGEND fACP WIRE DESCRIPTION TYPE A M98: 500 I I 8 GAUGE 2 CONDUCTOR FPLP B M98: 0 I I 4 GAUGE 2 CONDUCTOR FPLP C M98: 02 I 4 GAUGE 2 CONDUCTOR FPLP D M98: 03 I 4 GAUGE 2 CONDUCTOR FPLP M96:04 I 4 GAUGE 2 CONDUCTOR FPLP SBUS I 8 GAUGE 4 CONDUCTOR FPLP gt Coded Low 75 75 81 81 88 85 96 92 Honeyweii Fa ren hytr" Series WE POWER OF CONNECTED Panel ID: Location: ParL# IFP -300 IDP -Photo, Photo-T,PhotoR 1 54th SL Smrthrenter afwi s 513th IDP -Fire -CO IDP -Heat, Heat -HT, ROR IDP-Beam,B a -T N IDP Acdllmate IDP -Photo W P -Phot R - IDP-Pho T - IDP -Heat -W IDP-Heat-ROR- IDP -Heat - DP -Con IDP -Control -6 IDP -Mon to , Minimon IDP -Monitor -2 DP -Monitor -10 11FP- 300/ECS IDP Devices Description Fire Alarm Control Unit Smoke detector Fire -CO detector Heat detector Beam detector Duct housing DP Acclimate Photo W Photo -R -W Photo -T -W Heat -W Heat-ROR-w Heat -HT -W Control ontrol-6 Monitor, Minimon Monitor -2 Monitor -10 IDP -Pull -SA, Pull -DA Puii-SA, Pull -DA IDP -Relay Relay (DP -Relay -6 Relay -6 IDP-RelayMon-2 Rela Mon -2 IDP -Zone Zone IDP -Zone -6 Zone -6 IDP -Iso (Isolator Module) Iso (Isolator Module) IDP -ISO -6 ISO -6 B224BI B200S F.xtroCi B200SR B200S-LF B200SR-LF B224RB RTS151 RTS151KEY RA100Z 6815 RA -2000 RA -1000 RA -100 5824 5496 RP 10 0 865-4 5865-3 880 CELL -MOD K -NIC SK -FM SK-FSL P- G EC NVCM E VV24 ECS -RPU ECS -LOC ECS-tNT5OW ECS-INT5OW ECS -50W EC 125 ECS-DUAL5OW ECS-50VVBU NAC #f NAC NAC NAC Isolator Base Sounder Base Sounder Base Sounder Base LF Sounder Base LF Rela Base Ma netic Remote Test Ke Activated Test Remote LED SLC ander LCD Remote Annunc LCD Remote Annunc LCD Remote Annunc Serial/Parallel Module Power Power E ander ander LED Annunciator 4G LED Annunciator 3G LED Driver Module Co Module Communicator Network Interface Card Fiber Module Fiber Module Wireless Gateway Voice control 1 Zone Expander Remote Pa in • Unit Local Operating Console 50 Watt Internal Amp 25 volts 50 Watt Internal Amp 70 volts 50 Watt Amplifier 125 Watt Amplifier 50/100 Watt Amp 50 Watt Backup Amplifier Notification 11 I Circuit Notification Appl Circuit Aux Power Circuit Aux Power Circuit 12 20 60 MN Model: IFP-300/ECS Fire Alarm Control Panel Volts: 24 VDC urren ndb Alarm &Type 1000 Ft. One -Way Ohms Max NAC Current 3.0 Amps Max Panel Current 6.0 Amps AWO Ohms Per Length(ft) Actual Vo 0.190 0.250 0.0000 .0000 00 6 0 00060.0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 004 0.0 0.0000 0.0000 0011 0.0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0018 0.0 0.0000 0.0000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Total Standby Current (Amp 06 .0000 0000 .0000 0000 0000 .0000 0000 0000 .0000 .0000 00 04 0000 0000 0000 0000 000 000 000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0.000 0.000 0.000 0.0 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.0 0.00 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.067 0.000 0.891 0.006 0.750 EOL %Drop 4 Solid 4 Solid 4 Solid 2.52 2.52 2.52 0.000 0.000 t 4 Solid 2.52 0.204 3.048 Total Alarm Current Amps) Standby Time In Hours 24 0.0 Totat StandhvAM R ui 4.8840.254 Total Comb ned AH ReuIred 514 ultlply By The Derating Factor 1.20 nimum Bette Am.HoutsRe uired 6.17 350 300 300 300 Time In Minutes / 60 (5 Mins) Total Atarm AH Reauired Configure Circuits .76 1.51 1.51 20.40 19.0 9.27 20.40 Print Page 0.00% 6.60% N/A N/A kOehs 412 Fmti( (75 1/1-6 4-0 kl,,,iki6( liect401/ yr44-41, ei,„A„sukt. Punk 1-1,5 cpv14. sin.ke dths. -Cvvit-peh qs cihot 1104 Auporyk. trita.056tlyvh, r rtecoA 0-4 Tv•kj4"t‘h ot4md-• 1(qvi kytv)<. Fire Permit Number 19-F-4).13 To schedU call 206-575-4407 TABLE A.18.4.3 Average Ambient Sound Level According to Location Location Business occupancies Educational occupancies Industrial occupancies Institutional occupancies Mercantile occupancies l‘lechanical rooms Piers and water -surrounded structures Places of assembly Residential occupancies Storage. occupancies Thoroughfares. high-density urban Thoroughllires, medium -density urban Thoroughfares. rural and suburban Tower occupancies Underground structures and windowless buildings Vehicles and vessels Average Ambient Sound Level (dBA) SS 45 80 50 40 85 40 55 35 30 70 55 40 35 40 50 5YVI3OL LEGEND FIRE ALARM CONTROL PANEL (IFP -300) FACP EIRE ALARM COMMUNICATOR (AES 7707) 1 AES MANUAL PULL STATION 3 F WALL MOUNTED HORN G 0 PHOTOELECTRIC SMOKE DETECTOR / CO2 I 2 @ R/A HEAT DETECTOR RATE Of ANTICIPATION I 0 F HEAT DETECTOR FIXED TEMPETURE i LF PHOTOELECTRIC SMOKE DETECTOR LOW FREQUENCY BASE G in EXTERNAL WALL MOUNTED WEATHERPROOF HORN STROBE 1 pi MONITOR MODULE 1 t CEILING MOUNTED STROBE G WALL MOUNTED STROBE G 3:E WP WEATHER PROOF XXcd CANDELA RATING Of STROBE LIGHT 0 0 CErr;171 'ifellt Without Comments As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire reventjon Bureau for conformance with current City .:indards. Acceptance is subject to errors and nissions which do not authorize violations of adopted randards and ordinances. The responsibility for the ,dequacy of design rests totally with the designer.. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: I (- kByLiAl", WI KE LEGEND FACP WIRE DESCRIPTION TYPE A M98: S00 I 18 GAUGE 2 CONDUCTOR FPLP B M98: 0 I 14 GAUGE 2 CONDUCTOR FPLP C M98: 02 14 GAUGE 2 CONDUCTOR FPLP D M98: 03 14 GAUGE 2 CONDUCTOR FPLP E M98:04 14 GAUGE 2 CONDUCTOR FPLP SSUS 18 GAUGE 4 CONDUCTOR FPLP TrII�D FLOOD M97: M003 HEAT DETECTOR (RATE OF ANTICIPATION) @ 1 35° 15 LOCATED NEAR THE NEAR THE FACP ON SECOND FLOOR CAUSEWAY. M97.: HEAT DETECTOR (FIXED TEMPERATURE) IS LOCATED IN THE ATTIC. 50' RADIUS FROM EACH HEAT DETECTOR. M98:03 (or NAC #3)15 DESIGNATED AS AUXILIARY POWER FOR THE THE SOUNDER BASES IN BUILDING D M98:0 I (or NAC # 1) SUPPLIES POWER TO THE NOTIFICATION DEVICES IN APARTMENTS D2, D4 4 D6 ONLY. M58:02 (or NAC#2) SUPPLIES POWER TO THE NOTIFICATION DEVICES IN APARTMENTS D I , D3 $ D5 ONLY. SECON 7 FLOOD M97. scar A1011 Description: to) CD C.) 4) CI .-" Address update ® 10/24/2019 a) 1 -- CD o (N! CV 0 AUGUST 28, 2019 Rev: 01 T. PENNINGTON thomas.pennington@sbdinc.com 1065F-43746 BUILDING D BUILD D lst, 2nd & 3rd PLR AUGUST 28, 2019 AutoCAD 2020 4-4 GS ❑ Drawn By: _ N . Job #: ai CU (U .— D1t lG Name: Plot Date: O CD FIZST FLOOR UJ. L..L2.. 1 N. i st, 2n % rc. TLOOf 1/8" = I'-0" Mathew Buntin NICET #144348 Fire Alarm Systems Level 111 (ERT NO. 1 VALID U 03/01/2020 TO OFF PREMESIS MONITORING CONTRACTOR 120 VAC (DEDICATED CKT.) SBUS FROM EXIST. FACP OR EOL if AES -7707 1' BAT (7HRY SENSOR POINT LIST POINT NO. DESCRIPTION AND LOCATION M97: 300 I HEAT DETECTOR RATE OF ANTICIPATION 135° M97: 5002 PHOTOELECTRIC SMOKE DETECTOR / CO2 M97: 5003 PHOTOELECTRIC SMOKE DETECTOR / CO2 M97: 5004 PHOTOELECTRIC SMOKE DETECTOR / CO2 M97: 5005 PHOTOELECTRIC SMOKE DETECTOR / CO2 M97: 500G PHOTOELECTRIC SMOKE DETECTOR / CO2 M97: 5007 PHOTOELECTRIC SMOKE DETECTOR / CO2 M97: 5008 PHOTOELECTRIC SMOKE DETECTOR / CO2 M97: 5009 PHOTOELECTRIC SMOKE DETECTOR / CO2 M97: 50 I 0 PHOTOELECTRIC SMOKE DETECTOR / CO2 M97: 50 I I PHOTOELECTRIC SMOKE DETECTOR / CO2 M97: SOI 2 HEAT DETECTOR FIXED TEMP. M97: SOI 3 PHOTOELECTRIC SMOKE DETECTOR / CO2 M97: 50 14 PHOTOELECTRIC SMOKE DETECTOR / CO2 EIRE ALARM CONTROL UNIT POIN T LIST SBUS p # 18/4 AWG -� ANNUCIATOR RA -1000 SBUS #18/4 AWG �HouT SBUS 67 #18/4 AWG #18/2AWG -� 120VAC (DEDICATED CKT.) FAC P IFP -300 IN ADDRESSABLE FIRE ALARM CONTROL. COMMUNICATOR SLC Oma• <1 C. v C:1 —D NAC- 1 #14/2 AWG (CLAS MODULE POII\T LIST POINT NO. DESCRIPTION AND LOCATION M97: M00 I 2nd FLOOR 5. PULL STATION M97: M002 I st FLOOR S. PULL STATION M97: M003 3rd FLOOR 5. PULL STATION ERE ALAR V CONTROL UNIT F'OI NT LIST V\./ CEILING/DECK CEILING MOUNTED HORN/STROBE SEE NOTE 2 SEE NOTE 4 6'-8" (80") NOTES: SEE NOTE 5 5'-0" CEILING MOUNTED HEAT/SMOKE SEE NOTE 1 WALL MOUNTED HORN/STROBE FAA SEE NOTE 6 (60") TYP. MAX 4'-0" (48") MIN 3'-6" (42") PULL STATION 0 FACU CEILING MOUNTED HEAT/SMOKE SEE NOTE 1 SUSPENDED CEILING CEILING MOUNTED HORN/STROBE SEE NOTE 3 FAPS SEE NOTE 5 MAX 6'-0" (72") & MIN 5'-6" (66") TYP. FINISHED FLOOR . LOCATE CEILING MOUNTED HEAT/SMOKE DETECTORS ON THE BOTTOM OF THE DECK/SUSPENDED CEILING (NOT ON BOTTOM OF STRUCTURAL MEMBERS), AND AS INDICATED IN NEPA 72. 2. LOCATE CEILING MOUNTED NOTIFICATION DEVICES ON BOTTOM OF BEAMS OR JOISTS; WITH CLEAR LINE OF SITE IN ALL DIRECTIONS; NO GREATER THAN THIRTY (30) FEET ABOVE THE FINISHED FLOOR; AND AS INDICATED IN NEPA 72. 3. LOCATE CEILING MOUNTED NOTIFICATION DEVICES FLUSH WITH THE SUSPENDED CEILING; ALIGNED WITH LIGHTING, SPRINKLES, AND OTHER ARCHITECTURAL FIXTURES; WITH CLEAR LINE OF SITE IN ALL DIRECTIONS; NO GREATER THAN THIRTY (30) FEET A.F.F. ; AND AS INDICATED IN NEPA 72. 4. LOCATE WALL MOUNTED NOTIFICATION DEVICE5 AT 80" A.F.F TO BOTTOM OF BACK BOX. 5. COORDINATE EXACT MOUNTING HEIGHT OF CONTROL PANELS, ANNUNCIATORS, AND POWER SUPPLIES WITH THE GENERAL CONTRACTOR, ELECTRICAL_ CONTRACTOR AND AHJ PRIOR TO INSTALLATION. 6. MEASURED TO THE OPERABLE PART OF THE PULL STATION. a a n M97. M97: M97: M97: M004 M003 M002 M001 O O© 0® 0® 0® ® OO R/A LF LF LF LF LF F M97: M97: 11497. 11497: M97: M97: 11497: M97: /1/197: M97. M97: M97: M97: 5001 5002 5003 5004 5005 5006 5007 5008 5009 5010 5011 5012 5013 #18/2 AWG (CLASS B) 15cd s B)—/ NAC -2 #14/2 AWG (CLASS B) NAC 3 #14/2 AWG (CLASS B NAC -4 +, ,71_ #14/2 AWG (CLASS B BATTERY 1 BATTERY 110cd n 15cd 110cd EL WP v 75cd 15cd 110cd 15cd 110cd 15cd 110ca' ©LF©LF ©LF ©LF ©LF LF CEILO Af'A TME N.T.S. \IT 5U I LDI NG D MISER. DIAGAV LF M97' 5014 TYPICAL DEVICE MOUNTft\G hTh!GhIT N.T.S.