Loading...
HomeMy WebLinkAboutPP - 13001 40TH AVE S - STARK RESIDENCE - PERMITS AND PLANS13001 40TH AVE S ASSOCIATED PERMITS 18-5-031 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 192080-0005 Site Address: 13001 - 40th Ave S, Tukwila, WA 98168 Suite Number: / Floor: Tenant Name: Dixie Stark Property Owner's Name: Dixie Stark Mailing Address: P.O Box 80304 Seattle WA 98108 City State Zip New Tenant? ❑ - Yes ❑ - No CONTACT PERSON -if there are questions about the submittal. Name: Anthony Baldonado Day Telephone: 425-271-5598 Company Name: Moore Fire Protection Mailing Address: 14401 Issaquah -Hobart Rd SE. Suite 303 Issaquah WA. 98027 City State Zip E-mail Address: anthony@moorefire.com Fax Number: 425-496-8363 Contractor's City of Tukwila NICET III number: MOOREFP116NP Business License number: BUS -0996973 Total number of new/relocated devices or sprinkler heads: 22 Valuation of Project (contractor's bid price): $ 4,950 Scope of Work (please provide detailed information): Installation of new 22 -head wet automatic fire sprinkler system per NFPA 13D and City of Tukwila Fire Marshal standards. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER QR AUTHORIZED AGENT: Signature: j �'��'L' Date: 1/26/18 Print Name: Anthony Baldonado Day Telephone: 425-271-5598 Plan Permit App.doc 8/22/14 TFD FP Form 8 1s STUDY 11/2" POLY UNDERGROUN BY OTHERS. / / NO AS. PER NFPA/ /13D 8.3.4 (TYP). ,i/ CLOSET 0" CCES! It L L , FRPL GAS ISER DETAIL TION EETHIS AGE. DRAIN TO E PIPED TO XTERIOR. 50 CFM STACKE, WASH/t RYER MAIN FLOOR PLAN SCALE: 1/4" = 1' — 0" ® Without Comments 0 As Noted in Red Cl Per The Attached latter These plans have been reviewed by The Tukwila fire Prevention Bureau for conformance Yvith current City standards. Acceptance is subjeci r <.,-rrors and omissions which do not authorize violations of adopted standards : J ordinances, The responsibility for the adequacy of design sjsts totally with the designer. Additions, deletions c e:vislons to these drawings after this date will \hold tits , Licceptance and 'MP require a resubmittai of rays::-: ;,irawings for subsequent approval. Final acceptance .subject to field test and Inspection by The Tukwila Fire Prevention Bureau. 101-0" /NO AS. PER NFPA/ 13D 8.3.4 (TYP). T1s4k, J I ex¢erio r' WP 414)04; ( el) 36 fio) C 6vc.i) -Fes+ re(tv;rt,d`- '6-,./,,';-(14107 and O. 3 6"aTlie", i• '/`JQ e pact iddress .or shut down or r e to tiofapproval. PLATE HEIGHT ATTIC r - MAS 1, LIVING NORTH SECTION SCALE: 1/4" = 1' - 0" ATTIC FLOOR PLATE HEIGHT MAIN FLOOR CODE (ICAC REFERENCES 8.3 LOCATION OF SPRINKLERS: 8.3.1 Sprinklers shall be installed in all areas except where omission is permitted by 8.3.2 through 8.3.8. 8.3.2 Sprinklers shall not be required in bathrooms of 55 ft2 and less. 8.3.3 Sprinklers shall not be required in clothes closets, linen closets, and pantries that meet all of the following conditions: (1) The area of the space does not exceed 24 ft2. (2) The walls and ceilings are surfaced with noncombustible or limited -combustible materials as defined in NFPA 220. 8.3.4 Sprinklers shall not be required in garages, open attached porches, carports, and similar structures. 8.3.5 Sprinklers shall not be required in attics with or without storage, penthouse equipment rooms, elevator machine rooms, concealed spaces dedicated exclusively to and containing only dwelling unit ventilation equipment, floor/ceiling spaces, elevator shafts, crawl spaces, and other concealed spaces that are not used or intended for living purposes. 8.3.6 Sprinklers shall not be required in covered, unheated projections of the building at entrances/exits as long as the dwelling unit has another means of egress. 8.3.7 Sprinklers shall not be required for ceiling pockets that meet the following conditions: (1) The total volume of all unprotected ceiling pockets in a compartment does not exceed 100 ft3. (2) The entire floor under the unprotected ceiling pocket is protected by the sprinklers at the lower ceiling elevation. (3) The interior finish of the unprotected ceiling pocket excluding decorative treatments is noncombustible or limited -combustible material. (4) Skylights not exceeding 32 ft2 shall be permitted to have a plastic cover. 8.3.8 Sprinklers shall not be required in closets in garages and exterior closets (regardless of size) located on exterior balconies, exterior breezeways/corridors, or accessed from outdoors where the closet does not have doors or unprotected penetrations directly into the dwelling unit. 8.3.9 Sprinklers shall be installed in any closet used for heating and/or air-conditioning equipment, washers and/or dryers, or water heaters except as allowed by 8.3.8. STARK RESIDENCE — TUKWILA A LIST OF APPROVED PRODUCTS FOR USE WITH BLAZEMASTER CPVC PIPE IS INCLUDED WITH THE PRODUCT SPECIFICATIONS BOOKLET. FOR A COMPLETE AND UP-TO-DATE PRODUCT SEARCH, PLEASE GO ONLINE TO. <http://www.lubrizol.com/CPUC/Chemica lCompatibilityFinder.html> MAXIMUM SUPPORT SPACING FOR CPVC PIPING PIPE SIZE 3/4" 1" 1-1/4" 1-1/2" 2" FEET._METE R 5-1/2 (1.7) 6 1.8 6-1/2 (2.0) 7 (2.1) 8 (2.4) Hanger No. 09W Pipe Strap Wood Screw #18 x 1 %'--.., ',•-��� ,... Pipe strap (Short) ...... ' >/\ L--, P _/., f,l .7_7.7 , _....... //.,,// 4 /// v //. [/.. /!////.'////;'/ Al / `- Wood Joist, Beam or Deck Pipe Wood Screw #18 x 14,4" Hanger No. 19W Offset Pipe Hanger , Pipe Offset Pipe Hanger . r 7 / \1 / / / / / / / / / ; / / S 130TH ST 11/2" POLY UNDERGROUND- BY OTHERS. Wood Joist, Beam or Deck 1" TAP Hanger No. 17W Pipe Strap Pipe Strap —, Wood Screw#12 x 1Y.'- - NEW 1" DOM/FIRE METER. /;may-, / � Wood Joist or Bastin Pipe / / 13001 40th Ave S, Tukwila, WA 98168 SITE SPECIFICATIONS AH3: Tukwila Fire Marshal Owner/Lessee: Related Permit No:... D17-0082 Occupancy Type: Residential Construction Type: V -B No. Of Stories: 2 Parcel No: Legal Description: General Description: New two-story SFR. DAVIS REPLAT TR # 54 RIVERSIDE TR LESS CO FIRE FLOW: RD Provided by Dylan Bailey, King County Water District 125. Static pressure is 111 PSI with 2,708 GPM available at 20 PSI residual pressure. SYSTEM SPECIFICATIONS BUILDING CODE: 2015 IRC with WA State Amendments SYSTEM TYPE: 2016 NFPA 13D Wet Sprinkler System SPRINKLER COVERAGE: Dixie Stark P.O. BOX 80304 Seattle, WA 98108 192080-0005 18'-0" X 18'-0" 324 ft2 max. in rooms with a single head. 16'-0" X 16'-0" 256 ft2 max. in rooms with multiple heads. SPRINKLER SPACING: Single Residential Pendent in a Room: 9'-0" max. from any wall. Multiple Residential Pendents in a Room: 16'-0" max. between heads. 8'-0" max. from any wall. 8'-0" min. between heads. SPRINKLER DETAILS: Residential flat plate concealed 4.9K pendents are used throughout. HAZARD CLASSIFICATION: All areas are designed for a 0.05 gpm/ft2 density for Residential occupancy and a maximum 324 ft2 coverage area in rooms with a single head and 256 ft2 per head in rooms with multiple PIPING DETAILS: All aboveground piping denoted with only the pipe diameter to be CPVC plastic with CPVC fittings except as noted on the riser detail. SUPPLY: A new 1" tap runs approx. 30' to a new 1" combination dom/fire meter. 11/2" Poly underground continues approx. 57' to a 1" male threaded adapter left by others in the water heater closet. All underground by others. Moore Fire's scope of work to begin at 1" male threaded adapter left by others, DCVA and riser to be 1". GENERAL NOTES AND LIABILITY: All system piping is to be supported per manufacturer's specifications and is to be secured to prevent lateral movement. Pipe is to be secured to prevent sprinkler head movement. Moore Fire Protection's warranty of work does not cover any damage due to freeze related problems. Wet piping shall be protected against temperatures below 40 degrees Fahrenheit. Insulation installed for this purpose shall be located on the cold side of the pipe only with no insulation on the warm side of the pipe facing the heated interior. Coordinate with general and/or insulation contractor. All insulation to be by others. Moore Fire Protection shall not be responsible for the ability of the structure to adequately support the fire sprinkler system or any appurtenances thereof. Owner is responsible for the periodic inspection, testing and maintenance of the water based fire protection system(s) in accordance with the requirements of Chapter 12 of NFPA 13D. PAID JAN 23 201P, TUKWILA FIRE 2 ( 2-4, 4 bs' DRAWING NO. Revisions Sprinkler Legend State License a N N LL 0 0 ,-1 Tyco LFII QR. White Conc. Res. Pendant K=4.9 Total Heads For Project: N 0 DOPE FIRE SCOPEC-E WORK TO BEGIN 4, U LE: CI4ECK, Y .7 Tic , ixTur i 0 r r OaseNMNmNtiNe, • 1 t,o m W Ln rn rJ sf E U ai : 10 E N. C 0 Lo �!' C LL 0• u 192080-0005 ' m axa'z4i s � z maas; T U W 17 SITE PLAN SCALE: 1/8" = 1' 101 -On 0 a. LL. Sheet Size: 24x36 Scale: AS NOTED A. BALDONADO PRINKLER OVERAGE SHOWN N MAIN FLOOR. RE°D-MI P RR.311.S3.2 1 1/2" DIA. HANDRAIL AT 36" ABV. STAIR NOSING OPEN TO BELOW SPRINKLERS IN "OPEN TO BELOW" TO BE STAINLESS STEEL FINISH. REF.— 18" MIN DISTANCE TO FACE OF OVEN. OPEN TO BELOW SPRINKLERS IN "OPEN TO BELOW" TO BE STAINLESS STEEL FINISH. UPPER FLOOR PLAN SCALE: 1/4" = 1' - 0" 10'-0" OVEN W/ COOKTOP Hydraulic Information A OCCUPANCY CLASSIFICATION Residential DENSITY (gpm/ft2) 0.05 for 512.00ft2 TOTAL HEADS FLOWING 2 K -FACTOR 4.9 TOTAL WATER REQUIRED 26.32 TOTAL PRESSURE REQUIRED 43.444 BASE of RISER (gpm) 26.32 BASE of RISER (psi) 43.444 ` SAFETY MARGIN (psi) +67.539 (60.9%) CLOUD A DENOTES 2 MOST DEMANDING HEADS IN A SINGLE COMPARTMENT CALCULATED AT 16'-0" X 16'-0" SPACING. CLOUD B DENOTES HEADS TO BE USED FOR FUNCTIONAL FLOW TEST, WHICH HAVE A COMPARABLE DEMAND TO THE ACTUAL TWO MOST DEMANDING HEADS IN A SINGLE COMPARTMENT AT 16'-0" X 16'-O" MAX. SPACING. TEST HEADS HAVE BEEN CHOSEN FOR SAFE ACCESS. Hydraulic Information B OCCUPANCY CLASSIFICATION Residential DENSITY (gpm/ft2) 0.05 for 512.00ft2 TOTAL HEADS FLOWING 2 K -FACTOR 4.9 TOTAL WATER REQUIRED 26.25 TOTAL PRESSURE REQUIRED 38.935 BASE of RISER (gpm) 26.25 BASE of RISER (psi) 38.935 SAFETY MARGIN (psi) +72.048 (64.9%) 0' E H Sprinkler Legend 0 >• U) State License r1 LL 0 0 rl Tyco LFII QR. White Conc. Res. Pendant K=4.9 • 1 • M torn d- N • O L Q1 (i.__L Ln O N O *-1 N C .— O N �J' C v �p E- 0 OW SIM Parcel: 192080-0005 Scale: AS NOTED i-1 1 N 1-1 0) Ri ID A. BALDONADO C W