1441041STAVE S ASSOCIATED PERMITS 10-F-081 07-F-234 07-S-144 FIRE PROTEeTION, INC. PO AIX 12942 MILL MEEK, WA 91012 (425) 290-99991111.190-911-1125 FAX (4251353.4546 May 9, 2010 City of Tukwila -PLAN REVIEW RE; FIRE ALARM SYSTEM Please find enclosed plans for FIRE ALARM SYSTEM. The system has been designed per NFPA 72, 2002 edition requirements as well as WAC, IBC, IFC 2006, NEC current and your additional requirements. Fire Protection, Inc. will relocate 1 heat sensor, 1 strobe, and 1 horn/strobe on the existing system. The building is fully -sprinkled. The system shall monitor by zone activation as well as separate trouble signals. Monitoring shall be provided via UL listed Central Station, The Alarm Center LACEY, WA., over 2 analog lines via a built in DACT. Audibility shall be in compliance with NFPA standards with a 10 inch bell located on the outside of the building in the top 25% with a 117 candela strobe facing the first in -coming FIRE DEPARTMENT vehicles for easy building location. Interior DB shall be 75 DB minimum throughout. A full service and monitoring agreement is in force for the proper service and maintenance per NFPA requirements. All systems shall be UL certificated and placard. A full pre-test and NFPA form shall be conducted and completed prior to calling the AHJ for acceptance testing. INSTALLATION COMPANY Fire Protection, Inc. 1730 Gibson Rd. Everett, WA 98204 WSCL# FIREPI*021ML UL CERT #608242-002 JOB SITE ADDRESS Riverton Terrace 14410 41st Ave S Unit #203 Tukwila, WA. PAID MAY 11 2010 TUKWILA FIRE APPROVED UL MONITORING COMPANY Alarm Center, Inc./FPI 4300 3rd Ave. SE Lacey, WA 800-429-0991 UL CERT #902799-02 CONTRACTUAL RESPONSIBLE PARTIES Installation; Monitoring; Service; Testing; Runner Serv; Fire Protection, Inc. UL Cert; Fire Protection, Inc. AMBIENT TEMPERATURES No area with alarm service equipment shall fall below 40 degrees, common areas shall be at 68 degrees per builder AMBIENT NOISE RANGE All areas serviced by the Fire Alarm Control and notification system will be as listed for per UBC listings, per builder. SEQUENCE OF OPERATIONS All Alarm and Trouble conditions shall enunciate at FACP as well as remote notify UL listed Central Station. Zones of alarm shall cause for all notification circuits to activate, send alarm zone to CS, re -dispatch to Fire and dispatch FPI runner service. Trouble and supervisory signals shall transmit to CS which will dispatch FPI runner service to site, (no notification circuits shall activate.) On site emergency contact personnel shall be notified. Wet Waterflow ALARMS shall be retarded by a period of not more than 45 seconds. Low air shall activate at 251bs, causing for a supervisory signal. A short on FACP smoke, Waterflow Switches, (wet and dry) and pull station shall cause alarm. Shorts on PIV, tamper and Hi -low air zones shall cause a Supervisory condition. Opens on any zones shall cause for a trouble signal. Should you have any further questions, please feel free to contact me directly. Roy L. Cats Project Manager CFPS #1473**NICET-4 #09786**SFD #SCP -9955 CITY OF REDMOND DESIGNER OF RECORD #B-0-002 • t� cn �o z m w m =t 11 0 z -o z 11 1 111 1111 1111.,ti1HtIIIIII.tfiiti s KING COUNTY H usJo Aurnoury a!1Taan 'iemmTCVJ T ue PI7TisInflfl7 VVT %n•IST M LL_IKN'GHCL3 O�;Y Addressable Heat Detector IntelliKnight® addressable heat detectors combine accurate heat detection with pin -point location ID. An essential combination for any installation. IntelliKnight heat detectors are an essential component in virtually any IntelliKnight installation. The IntelliKnight panel recognizes each detector by its specific address, so precious seconds are not wasted in determining location of an alarm. Like other IntelliKnight detector models, the SD505-AHS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibfiity. Combine all this with the features you've come to expect from Silent Knight detectors—easy installation, stable operation, RF/transient protection, and vandal -resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model SD505-AHS Addressable Heat Detector The SD505-AHS is a heat detector suited to virtually any commercial setting. The SD505-AHS is an absolute temperature device. This means that it responds in alarm if the temperature goes above the trip point (programmed at the panel). The SD505-AHS provides accurate temperature measurement data to the fire alarm control panel. This heat detector is particularly suited to environments where smoke detectors cannot be used because of the presence of steam or cooking fumes, such as in a kitchen. Operation The SD505-AHS unit is made up of an externally mounted thermistor with a specially designed cover that protects the thermistor while allowing maximum air flow. The thermistor reads the temperature from the air it takes in. It then transmits a signal representing the temperature to the IntelliKnight panel. If the temperature exceeds the trip point (programmed at the panel), an alarm occurs. The status LED lights continuously during the alarm period. Under normal conditions, the status LED blinks approximately every 15 seconds, indicating that the head is communicating with the loop. Features • Low profile, 2 inches, including base • Absolute temperature device • Simple and reliable addressing • Uses digital communication protocol • The SD505-AHS is UL Listed and meets the requirements outlined in NFPA 72 Inspection Testing and Maintenance, Chapter 7. • CFSM listed • MEA listed • FM approved SILENT KNIGHT by Honeywell SD505-AHS Heat Detector Specifications Operating Voltage: 17 to 41 VDC Current Consumption: Standby: Alarm: .55 mA .55 mA Detection Temperature Range: 135°F to 150°F (57°C TO 65°C) Ambient Temperature: 32°F to 1200F (0°C to 49°C) Mounting: 4" SQR, 4" OCT Single gang mud ring Rated Spacing: 70' between sensors on smooth ceilings. Compatible Bases: (Sold Separately) SD505-6AB (6" Base) SD505-4AB (4" Base) Model SD505-AHS Addressable Heat Detector Engineering Specifications The contractor shall fumish and install where indicated on the plans, addressable heat detector Silent Knight SD505-AHS. The combination detector head, and twist -lock base, shall be UL® listed compatible with Silent Knight's lntelliKnight fire alarm control panels. The base shall permit direct interchange with Silent SD505-APS Photoelectric Smoke Detector, or SD505-AIS Ionization Smoke Detector. Base shall be the appropriate twist -lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. The vandal -resistant, security locking feature shall be used In those areas as indicated on the drawing. The locking feature shall be field removable when not required. Voltage and RF/transient suppression techniques shall be employed to minimize false alarm potential. N Diameter = 5-15/16" It Model SD5O5-6AB Detector Base (Front View) Height = 2 inches, including base Model SD5O5-AHS Detector Head (Front View) fs SILENT KNIGHT by Honeywell This document is not Intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. MI specifications are subject to change without notice. For more information, contact Silent Knight 7550 Meridian Cirde Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. MADE IN AMERICA FORM# 350229 Rev B,. 05/05 Copyright ® 2005 Silent Knight 6-,M, SYSTEM SENSOR` Selectable Output Horns, Strobes, and Horn/Strobes SpectrAlertAdvance selectable -output horns, strobes, and horn/strobes are rich with,features guaranteed to cut installation times and maximize profits. Features • Electrically compatible with existing SpectrAlert products • Automatic selection of 12- or 24 -volt operation at 15 and 15/75 candela • Plug-in design • Field selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185 • Same mounting plate for wall- and ceiling -mount units • Shorting spring on mounting plate for continuity check before installation •Tamper resistant construction • Outdoor wall and ceiling products rated from —40°F to 151°F • Design allows minimal intrusion into the back box • Horn rated at 88+ dbA at 16 volts • Rotary switch for horn tone and three volume selections • Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) outdoor requirements • Outdoor products NEMA 4X rated • Compatible with MDL sync module Agency Listings 54011 55512 S3593 3023572 MEA approved MEA452-05-E 7125-1653:1861mdoor Arabes) 7300-1653:187 (outdoor strobes) 7125-1653:188 0,o,Nsa°bes. chime/mrobes) 7135-1653-189 (home, chimes) �1 Sr CCTFlert A D V A N C E The SpoctrAlart Advance series of notification appliances is designed to simplify installations, with features such as plug in designs, instant feedback messages to ensure correct installation of individual devices, and 11 field -selectable candela settings for wall and ceiling strobes and horn/strobes. When installing Advance products, first attach a universal mounting plate to a four -inch square, four -inch octagon or double -gang junction box.The two -wire mounting plate attaches to a single -gang junction box. Next, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn, strobe or horn/strobe to the mounting plate by inserting the product's tabs in the mourting plate's grooves.The device will rotate into position,4ocking the product's pins into the mounting plates terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. The SpectrAlert Advance series includes outdoor notification appliances. Outdoor strobes and horn/strobes (two wire and four wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance horns, strobes and horn/strobes shall mount to a standard 4 x 4 x 11/2 -inch back box, 4 -inch octagon back box or double -gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 17/s -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12 -volt rated notification appliance circuit outputs shall operate between nine and 175 volts; 24 -volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full -wave rectified, unfiltered power supply. Strobes and horn/strobes shall have field -selectable candela settings induding 15,15/75, 30, 75, 95,110,115,135,150,177,185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn%Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three -pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder.The horn on horn/strobe models shall operate on a coded or non -coded power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit. The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires. The module shall mount to a 411/26 x 4" /,6 x 21/a -inch back box The module shall also control two Style Y (dass B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) K Series Operating Temperature —40°F to 151°F (-40°C to 66°C) Humidity Range 10 to 93% non -condensing (indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR' Operating Voltage Range' 8 to 17.5 V (12V nominal) or 16 to 33 V (24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions (including lens) Wall mount dimensions (including lens) 6.8" diameter x 25' high (173 mm diameter x 64 mm high) 5.61x4.7Wx25"D(142mmLx119mmWx64mmD) Horn dimensions 5.61x4.7Wx1.30(142mm Lx119mmWx33mmD) Wall -mount back box skirt dimensions (BBS -2, BBSW-2) 5.91 x 5.0W x 22D (151 mm L x 128 mm W x 56 mm D) Ceiling -mount back box skirt dimensions (BBSC-2, BBSCW-2) 7.1" diameter x 2.25 -high (180 mm diameter x 57 mm high) Wall -mount weatherproof back box dimensions (SA-WBB) 5.71 x 5.1"W x 2.0•D (145 mm L x 130 mm W x 51 mm D) Ceiling -mount weatherproof back box dimensions (SA-WBBC) 7.1" diameter x 2.0 -high (180 mm diameter x 51 mm high) Wall -mount trim ring dimensions (TR -HS, TRW -HS) 5.71 x 4.812"W x 0.35D (146 mm L x 122 W mm x 9 D mm) Ceiling -mount trim ring dimensions (TRC -HS, TRCW-HS) 6.9' diameter x 0.35 high (176 mm diameter x 9 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time varying power source that is used on some power supply and panel outputs. 2. P 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05-0395.005 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) 8-17.5 Volts 16-33 Volts UL Max. Horn Current Draw (mA RMS) Candela DC FWR DC FWR Sound Pattern Standard Candela Range 15' 123 128 66 71 Temporal 15/75* 142 148 77 81 Temporal 30' NA NA 94 96 Temporal 75' NA NA 158 153 Non -temporal 95' NA NA 181 110 NA 115 NA NA 202 NA 210 High Candela Range 135 NA NA 228 150 NA NA 177 NA NA NA 185 NA 176 195 205 207 246 220 251 258 281 286 Non -temporal Non -temporal Coded Coded Coded 8-17.5 Volts 16-33 Volts dB DC FWR DC FWR High 57 55 69 75 Medium 44 49 58 69 Low 38 44 44 48 High 57 56 69 75 Medium 42 50 60 69 Low 41 44 50 50 High 57 55 69 75 Medium 44 51 56 69 Low 40 46 52 50 UL Max. Current Draw (mA RMS), 2 -wire Horn/Strobe, Standard Candela Range (15-115 cd) DC Input 8-17.5 Volts 16-33 Volts 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Nontemporal High 141 152 91 100 116 176 201 221 229 Non -temporal Medium 133 145 75 85 102 163 187 207 216 Non -temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High Temporal Medium Temporal Low Non -temporal High Non -temporal Medium Non -temporal Low 136 129 129 142 134 132 155 152 151 161 155 154 88 78 76 103 85 97 112 88 103 86 101 126 110 105 80 112 95 90 168 160 160 181 166 161 190 184 184 203 189 184 210 202 194 221 208 202 218 206 201 229 216 211 UL Max. Current Draw (mA RMS), 2 -wire Horn/Strobe, High Candela Range (135-185 cd) DC Input 16-33 Volts 135 150 177 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 . 292 Temporal Low 207 221 248 256 Non -temporal High 255 270 303 309 Non -temporal High 233 248 275 281 Non -temporal Medium 242 259 293 299 Non -temporal Medium 219 232 262 267 Non -temporal Low 238 254 291 295 Nontemporal Low 214 229 256 262 Candela Derating For K series products used at tow temperatures, listed candela ratings must be reduced in accordance with this table. Strobe Output (cd) Listed Candela Candela rating at -40°F 15 Do not use below 32°F 15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 Horn Tones and Sound Output Data Horn and Horn/Strobe Output (dBA) Switch 8-17.5 16-33 24 Volt Nominal Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non -temporal High 82 82 88 88 93 92 100 100 5 Non -temporal Medium 78 78 85 85 90 90 98 98 6 Non -temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8+ Coded Medium 78 78 85 85 90 90 97 98 9' Coded Low 75 75 81 81 88 85 96 92 ?Settings 7, 8, and 9 are not available on 2 -wire horn/strobe. A0S039S-OOS SpectrAlert Advance Dimensions 2.5= 5.98' Op 44 0 Wall -mount horn/strobes r-2.23:1 le -2.251 Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information Model Description Wall Horn/Strobes P2R*t 2 -wire Horn/Strobe, Standard cd*, Red P2RH* 2 -wire Horn/Strobe, High cd, Red P2RK*° 2 -wire Horn/Strobe, Standard cd, Red, Outdoor P2RHK° 2 -wire Horn/Strobe, High cd, Red, Outdoor P2W* 2 -wire Horn/Strobe, Standard cd, White P2WH* 2 -wire Horn/Strobe, High cd, White P4R* 4 -wire Horn/Strobe, Standard cd, Red P4RH* 4 -wire Horn/Strobe, High cd, Red P4RK° 4 -wire Horn/Strobe, Standard cd, Red, Outdoor P4RHK° 4 -wire Horn/Strobe, High cd, Red, Outdoor P4W' 4 -wire Horn/Strobe, Standard cd, White P4WH* 4 -wire Hom/Strobe, High cd, White Wall Strobes SR*t Strobe, Standard cd, Red SRH*t Strobe, High cd, Red SRK° Strobe, Standard cd, Red, Outdoor SRHK Strobe, High cd, Red, Outdoor SW* Strobe, Standard cd, White SWH* Strobe, High cd, White Ceiling Horn/Strobes PC2R* 2 -wire Horn/Strobe, Standard cd, Red PC2RH* 2 -wire Horn/Strobe, High cd, Red PC2RK° 2 -wire Horn/Strobe, Standard cd, Red, Outdoor PC2RHK° 2 -wire Horn/Strobe, High cd, Red, Outdoor PC2W*t 2 -wire Horn/Strobe, Standard cd, White PC2WH*t 2 -wire Horn/Strobe, High cd, White PC4R 4 -wire Horn/Strobe, Standard cd, Red PC4RH 4 -wire Horn/Strobe, High cd, Red PC4RK 4 -wire Horn/Strobe, Standard cd, Red, Outdoor PC4RHK° 4 -wire Horn/Strobe, High cd, Red, Outdoor Ceiling -mount horn/strobes h 2.0 7.1• D a. Wall weatherproof back box Ceiling weatherproof back box Model Description Ceiling Hom/Strobes (cont'd.) PC4W 4 -wire Horn/Strobe, Standard cd, White PC4WH 4 -wire Horn/Strobe, High cd, White Ceiling Strobes SCR* Strobe, Standard cd, Red SCRH* Strobe, High cd, Red SCRK° Strobe, Standard cd, Red, Outdoor SCRHK° Strobe, High cd, Red, Outdoor SCW*t Strobe, Standard cd, White SCWH*t Strobe, High cd, White Horns HR Horn, Red HR} HW Horn, Red, Outdoor Horn, White Accessories BBS -2 Back Box Skirt, Wall, Red BBSW-2 Back Box Skirt, Wall, White BBSC-2 Back Box Skirt, Ceiling, Red BBSCW-2 Back Box Skirt, Ceiling, White TR -HS Trim Ring, Wall, Red TRW -HS Trim Ring, Wall White TRC -HS Trim Ring, Ceiling, Red TRCW-HS Trim Ring, Ceiling, White Notes: * Add "-P"to model number for plain housing (no 'FIRE' marking on cover), e.g., P2R-P. t Add"-SP'to model number for "FUEGO' marking on cover, e.g., P2R-SP. *"Standard cd," refers to strobes that indude 15,15/75, 30, 75, 95,110, and 115 candela settings.'High cd' refers to strobes that indude 135, 150, 177, and 185 candela settings. All outdoor units ending in include a weatherproof back box. ti Add "-R"to model number for weatherproof replacement device (no back box included). SYSTEM _$ SENSOR 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax 630-377-6495 02008 System Sorsa. Product spermcoo,ss subje¢ To change wnkaut not ce Not systemsensm corn is current product trdomuuanodudig the latest version attits data sheet *05-0395-005.8/08.12018 ACCEPTED p Without Comments _fa As Noted in Red p Per The Attached Letter These plans have been reviewed by The Tukwila Fire :vention Bureau for conformance with current City st<:ndardS. Acc ep ? e 1:0 errors and omissions which do not 6Litt zF v ,? ons of adopted -';andards and ordinan,• , o.•si ility for the �d.-quacy of design '.e designer. Additions, deietaons drawingsafter this date will void this ut e_ Y `i require a resubmittal of revised drawl;r1.:. approval. Final acceptance is subject to fie id +cst and inspection by The Tukwila Fire Prevention Bureau, Date: / � f 0 By: INKWI A FIRE DEPARTMU Please call: 575.440 end give this job Nd. /o- a8 l ind exact address for shut. •xn4wr< 1,r rgst()ratPpf Arm3roval, NOTICE A completed, signed, Tiikwiia Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. FI E (Site Plan) DATE:04/30/07 TIME:11:28:08 — -- FILE:2-154109 Sheet 1 of 5 RevisionXX R RIVERTON TERRACE BUILDING "H" C[:NSFCT 111 IHMWittfl:it :'Cfl'IEnt.thE COORDINATE Wt Attf-I: i110,111.;"YP) FSW START POINT CITY CONNECTION I (BY OTHERS) 4" FIRE HYDRANT (EXISTING) ��. 4"x4"STORTZFDC 'L ! •1 (BY OTHER),_ i i 1 ccrIA}.f.� r❑ EYtit 11 WITH ?)0111)0 FITTI0. 1-71:1 ) 4,",CLAS. 52 DI Elk P.I.V.tv/ TAMPER ( OT 'S SE IIICE THRl ET BL tllF PERYII (fel.^) OD.1 1 *RI. -111, t[!ISt0 ELIAILI•.) 5 A51J fl E%.; I. Wrtflk :>w.kE t II:F. 5L] FIC». 1E51 Bir PAVUKST SOAr IRSI LOCAIICI1 1D11" tN_:INLE). -j ASPHALT PARKING c SITE SYMBOLS PIPING BY FSW - - EXISTING PIPING PIPING BY OTHERS FIRE DEPARTMENT CONNECTION Z-° POST INDICATOR VALVE 7111-111-.H1-111-111-111_111_ =ll1=11-1=1=111-111= ',111-111-111-111-911-1_ _III-L1=1J-Ill-UI Ill=a1=Ill-1.11-I_ -ll.1=1.1.1.=Ill-1.L= 11=111=111=111=1 1=z__I1l111i1i1111,1 4" FROM SUPPLY EXISTING FIRE HYDRANT GATE VALVE IN ROADWAY BOX NEW FIRE HYDRANT STREET CENTER LINE PROPERTY LINE MAINTAIN 2" ANNULAR CLEARANCE AROUND ALL CONCRETE PENETRATIONS FLOW TEST INFORMATION FLOW TEST INFORMATION GIVEN BY BCE ENGINEERING FLOW TEST LOCATION: WATER METER ACROSS S. 144th ST. FROM 4021 FLOW TEST DATE: 1/19/2007 STATIC PRESSURE 80 PSI RESIDUAL PRESSURE 52 PSI FLOWING: 2990.1 G.P.M. 1-1 11-1 I i-1 -ll l=I.11-lll= -111-111-1 101-111.-111= i=ll' -I11=1 111-111-111_ 1=111=111=1 -111-111-111: 11=111=111=� =III-III=1 I I- _-111=L-1 =111=111-11 H :=_111E-111-L-11=11=1ir_ =111E1 1=11=111=111: 1_I1-111-111- =111-111 _1111-1 1-1 8 I-., SPARE CABINET RISER ELEVATION FITTER / LISTER NOTES : 1. DISCHARGE MAIN DRAIN TO A SAFE LOCATION OUTSIDE. 2. MAINTAIN A 211 ANNULAR SPACE AROUND ALL PIPES PASSING THROUGH CONCRETE. HANGER LEGEND SPRINKLER HEADS UNDERGROUND NOTES: 1) ALL UNDERGROUND TO BE BY OTHERS. CONTRACTOR TO BE STATE LICENSED AND CERTIFIED TO INSTALL UNDERGROUND PIPING PER WAC 212-80. 2) PIPE TYPE AND CLASS TO MEET LOCAL JURISDICTION APPROVAL. 3) ALL UNDERGROUND PIPING SHALL HAVE 3 FEET MINIMUM BURY (TO TOP OF PIPE). 4) ALL UNDERGROUND PIPING SHALL BE UL LISTED AND/OR FM APPROVED FOR FIRE PROTECTION. ALL PIPING WITHIN 5'-0" OF BLDG TO BE MIN CLASS 52 DUCTILE IRON. 5) ALL UNDERGROUND PIPING SHALL BE RESTRAINED IN ACCORDANCE WITH THE SPECIFICATIONS AND NFPA 24 (LATEST EDITION). 6) ALL UNDERGROUND PIPING SHALL BE HYDROSTATICALLY TESTED AT NOT LESS THAN 200 PSI OR 50 PSI ABOVE STATIC PRESSURE IN EXCESS OF 150 PSI FOR TWO HOURS IN ACCORDANCE WITH NFPA 24 (LATEST EDITION). 7) ALL UNDERGROUND PIPING SHALL BE FLUSHED IN ACCORDANCE WITH NFPA 24 (LATEST EDITION). FLOW THE REQUIRED RATE UNTIL WATER IS CLEAR AS INDICATED BY NO COLLECTION OF FOREIGN MATERIAL IN BURLAP BAGS AT OUTLETS. 4" - 490 GPM 6" - 880 GPM 8" - 1,560 GPM 10" - 2,400 GPM 12" - 3,520 GPM 8) ALL UNDERGROUND PIPING SHALL BE STERILIZED PER LOCAL JURISDICTION REQUIREMENTS. RISER MATERIAL LIST Item Number Quantity Size Description Manufacturer 1 1 4" Wilkins Zurn 350ADA BGVIC GxG Backflow Preventer W/ Tamper Switch Wilkins/ Zurn 2 1 4" Victaulic Mod. 717 Check Valve GxG Victaulic 3 1 1W Victaulic 728 Firelock Ball Valve w/ Tamper Switch TxT Victaulic 4 1 1A Pressure Gauge Kennedy 5 1 11/, Potter VSR-SF Water Flow Indicator Potter Electric 6 1 1" AGF 1000 Test and Drain AGF 7 1 10" Electric Alarm Bell Potter Electric 8 12 head ---- Spare Head Cabinet containing a Stock of the Following Spare Sprinklers and Wrenches - PIPE TO LAUNDRY ROOM FLOOR DRAIN SPARE SPRINKLERS AND WRENCHES Quantity Description Manufacturer Pendent, Viking, VK404. BRASSNVHT 1/2" x 5.6K 155", QR, Concealed Viking 2 Upright, Viking VK 300, 1/2" x 5.6K 155',W, Brass Viking 6 Sidewall, Viking VK 450, WHT/ WHT 1/2" x 4.1K, 155", QR, Recessed Viking 2 Pendent, Viking VK 425, BRASS/ WHT 1/2" x 4,2K, 155", QR, Concealed Viking Sidewall, Viking VK 305, CHROME/ CHROME 1/2" x 5.6K, 155', QR, Recessed Viking Viking Wrench , Part No. 10896W/B Viking Viking Wrench, Part No. 10366W/B Viking Viking Wrench. Part No. 07398W Viking REVISIONS (FACING NORTH) GENERAL NOTES B 1 { H ) BUILDING CROSS SECTION SCALE: N.T.S. MAINTAIN 2" ANNULAR CLEARANCE AROUND ALL PIPE PASSING THROUGH CONCRETE d • s-0 RISER AREA FLOORPLAN SCALE: 112"=1'-0" SCOPE OF WORK FILE COPY FIRE SYSTEMS WEST (FSW) WILL PROVIDE AN AUTOMATIC WET PIPE FIRE PROTECTION SPRINKLER SYSTEM IN AN EXISTING MULTIFAMILY RESIDENCE. FSW WILL START WORK AT A FLANGE CONNECTION 6" INSIDE THE BUILDING (PROVIDED BY OTHERS) CLARIFICATIONS - ALL AREAS OF WET PIPE INCLUDING ALL VALVES AND RISERS MUST BE MAINTAINED BY OTHERS AT A MINIMUM 40°F TO PREVENT FREEZING. EXCLUSIONS - PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT - ELECTRICAL WIRING OF ANY KIND INCLUDING BUT NOT LIMITED TO WATERFLOW SWITCH, ELECTRIC BELL, AND TAMPER SWITCHES - CENTRAL STATION MONITORING EQUIPMENT, WIRING AND SERVICES DESIGN CRITERIA PER NFPA 13(2007) AND CITY OF TUKWILA e -RESIDENTIAL UNITS RESIDENTIAL HAZARD DESIGN DENSITY : PER HEAD LISTING FOR 4 ST DEMAND' C - ORRIDORS LIGHT HAZARD DESIGN DENSITY : 0.10 GPM / 5 HEADS -LOBBIES/ COMMUNITY ROOMS/ PUBLIC REST) OMS LIGHT HAZARD DESIGN DENSITY : 0.10 GPM / LARGE ROOM -STORAGE/ MECHANICAL ROOMS ORDINARY HAZARD GROUP 2 DESIGN DENSITY : 0.20 GPM / LARGE ROOM Cd>"rl� w,�'� Des e►,S,hrcr3 review Imo. dalcal S --A1 j4c1--41 18/��a�,.)/x(,,47,$ --' FO 44 hose toKnevi-fohs -lo bt etv:loru� w;h� /C�o ( 1bckl tiS c4�,s. Preivtd•e OI ilk deco,* Spoke_ 4rt+vhlil .S felfeter rller d FOL F•Oc +o ho�t `F-�tcw;ta P'ylrc tvoriC$ Spet,S . Pro.1 dc. hS4 4 ey40rior wect44 .. J'OO'� bell/ 31r064 0 ' - 17C c &p(cco.skso L(Se'c o-tkues):4b1d)xgt,. . Jiyh+ 11424va1 deMay4rcas oyry DESIGN CRITERIA AND NOTES A U -HOOK L L -ROD SYM TYPE MFG MODEL ORIFICE THREAD TEMP FINISH CANOPY QTY MK DATE BY DESCRIPTION B SUPER SCREW M WASHER PLATE A C CONCRETE INSERT N A D TOP BEAM CLAMP P POWDER DRIVEN STUD E R WEDGE ANCHOR A A F HDI -P T TRAPEZE A G CEILING FLANGE U APPROVALS REQUIRED: DISTRIBUTION: H SIDE BEAM BRACKET W AUTHORITY City of Tukwila 3 J SIDEWINDER X OWNER / ARCHITECT K SHORT CLIP Y TOTAL TOT OWNER / ARCHITECT FIRE SYSTEMS WEST 2 2 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UNDERWRITERS APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISER & DIMENSIONS SHOWN THUSLY (1'-6") WHICH ARE END TO END. 3.EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA #13. 4. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA #13. 5.PIPING SHALL BE IN ACCORDANCE WITH NFPA#13. 6. JOINING OF PIPE AND FITTINGS, THREADED AND WELDED SHALL BE IN ACCORDANCE WITH NFPA #13. 7. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY WET PIPE SPRINKLER SYSTEM. 8. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER OR HIS STRUCTURAL REPRESENTATIVE. 1. ALL MAIN AND GRIDDED BRANCHLINE PIPING TO BE SCHEDULE 10 JOINED W/ GROOVED COUPLINGS AND FITTINGS(UNO). 2. ALL TREE BRANCHLINE PIPING TO BE SCHEDULE 40 JOINED W/ CAST IRON THREADED FITTINGS. 3. ALL DRY MAIN PIPING TO BE SLOPED AT 114" PER 10'-0" AND ALL DRY LINE PIPING TO BE SLOPED AT 1/2" PER 10'-0". 4. ALL GROOVED COUPLINGS TO BE RIGID (" Jl ), UNLESS SHOWN AS: ("_: DENOTING A FLEXIBLE COUPLING. BUILDING PERMIT # 0 Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings atter this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance. is subject to fiefd test and inspection by The 0 Tukwila kwila Fire, Prevention Bureau. Date: (o )\S 7 By: AV11.. ( J' ( TUKWILA FIRE DEPARTMENZ, Please call: 575-4407, and give this job No. 1 `I and exact address for shut. down Q11 restoration approvafj,1 CONTRACT NAME: Riverton Terrace 14410 41st Avenue South Tukwila WA 98168 CONTRACT WITH: W.G. Clark Construction 401 Aurora Ave. N Seattle WA 98109 Project Manager Eric Peterson Phone: 206-624-5244 Fax: 206-682-7126 PAID MAY 11 2007 Tukwila Fire y}-250?(,_ ",-6( VICINITY MAP SCALE: N. T. S. SITE PLAN AND DETAILS Fire Systems West 219 Frontage Road North, Suite B Pacific, WA. 98047 (253) 833-1248 Fax: (253) 735-0113 WA CL# FIRESWI 140B1 Q.C. FAB BY: Q.C. INSTALL BY: DESIGNER DATE JOB NUMBER SHEET Steven Huff 04/30/07 2-16-6109 1 of 5 ,. WALL2n .1 3rd y A- LR) d, UNIT CORRIDOR -2 x 4 STUD 2' RAT INSUL.r. W 16" O.C. UNIT r.' UNIT CORRIDOR UNIT UNIT CORRIDOR 0', WALL (1 s ~3 FLR) n 16" BB UL. O O.C. p �' CEILING 2 x 12 J GIST @ 16" O.C. x 4 STUD 2 x 518 G.V6. 2" BATT IN BUILDING CROSS SECTION SCALE: N.T.S. MAINTAIN 2" ANNULAR CLEARANCE AROUND ALL PIPE PASSING THROUGH CONCRETE d • s-0 RISER AREA FLOORPLAN SCALE: 112"=1'-0" SCOPE OF WORK FILE COPY FIRE SYSTEMS WEST (FSW) WILL PROVIDE AN AUTOMATIC WET PIPE FIRE PROTECTION SPRINKLER SYSTEM IN AN EXISTING MULTIFAMILY RESIDENCE. FSW WILL START WORK AT A FLANGE CONNECTION 6" INSIDE THE BUILDING (PROVIDED BY OTHERS) CLARIFICATIONS - ALL AREAS OF WET PIPE INCLUDING ALL VALVES AND RISERS MUST BE MAINTAINED BY OTHERS AT A MINIMUM 40°F TO PREVENT FREEZING. EXCLUSIONS - PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT - ELECTRICAL WIRING OF ANY KIND INCLUDING BUT NOT LIMITED TO WATERFLOW SWITCH, ELECTRIC BELL, AND TAMPER SWITCHES - CENTRAL STATION MONITORING EQUIPMENT, WIRING AND SERVICES DESIGN CRITERIA PER NFPA 13(2007) AND CITY OF TUKWILA e -RESIDENTIAL UNITS RESIDENTIAL HAZARD DESIGN DENSITY : PER HEAD LISTING FOR 4 ST DEMAND' C - ORRIDORS LIGHT HAZARD DESIGN DENSITY : 0.10 GPM / 5 HEADS -LOBBIES/ COMMUNITY ROOMS/ PUBLIC REST) OMS LIGHT HAZARD DESIGN DENSITY : 0.10 GPM / LARGE ROOM -STORAGE/ MECHANICAL ROOMS ORDINARY HAZARD GROUP 2 DESIGN DENSITY : 0.20 GPM / LARGE ROOM Cd>"rl� w,�'� Des e►,S,hrcr3 review Imo. dalcal S --A1 j4c1--41 18/��a�,.)/x(,,47,$ --' FO 44 hose toKnevi-fohs -lo bt etv:loru� w;h� /C�o ( 1bckl tiS c4�,s. Preivtd•e OI ilk deco,* Spoke_ 4rt+vhlil .S felfeter rller d FOL F•Oc +o ho�t `F-�tcw;ta P'ylrc tvoriC$ Spet,S . Pro.1 dc. hS4 4 ey40rior wect44 .. J'OO'� bell/ 31r064 0 ' - 17C c &p(cco.skso L(Se'c o-tkues):4b1d)xgt,. . Jiyh+ 11424va1 deMay4rcas oyry DESIGN CRITERIA AND NOTES A U -HOOK L L -ROD SYM TYPE MFG MODEL ORIFICE THREAD TEMP FINISH CANOPY QTY MK DATE BY DESCRIPTION B SUPER SCREW M WASHER PLATE A C CONCRETE INSERT N A D TOP BEAM CLAMP P POWDER DRIVEN STUD E R WEDGE ANCHOR A A F HDI -P T TRAPEZE A G CEILING FLANGE U APPROVALS REQUIRED: DISTRIBUTION: H SIDE BEAM BRACKET W AUTHORITY City of Tukwila 3 J SIDEWINDER X OWNER / ARCHITECT K SHORT CLIP Y TOTAL TOT OWNER / ARCHITECT FIRE SYSTEMS WEST 2 2 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UNDERWRITERS APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISER & DIMENSIONS SHOWN THUSLY (1'-6") WHICH ARE END TO END. 3.EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA #13. 4. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA #13. 5.PIPING SHALL BE IN ACCORDANCE WITH NFPA#13. 6. JOINING OF PIPE AND FITTINGS, THREADED AND WELDED SHALL BE IN ACCORDANCE WITH NFPA #13. 7. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY WET PIPE SPRINKLER SYSTEM. 8. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER OR HIS STRUCTURAL REPRESENTATIVE. 1. ALL MAIN AND GRIDDED BRANCHLINE PIPING TO BE SCHEDULE 10 JOINED W/ GROOVED COUPLINGS AND FITTINGS(UNO). 2. ALL TREE BRANCHLINE PIPING TO BE SCHEDULE 40 JOINED W/ CAST IRON THREADED FITTINGS. 3. ALL DRY MAIN PIPING TO BE SLOPED AT 114" PER 10'-0" AND ALL DRY LINE PIPING TO BE SLOPED AT 1/2" PER 10'-0". 4. ALL GROOVED COUPLINGS TO BE RIGID (" Jl ), UNLESS SHOWN AS: ("_: DENOTING A FLEXIBLE COUPLING. BUILDING PERMIT # 0 Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings atter this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance. is subject to fiefd test and inspection by The 0 Tukwila kwila Fire, Prevention Bureau. Date: (o )\S 7 By: AV11.. ( J' ( TUKWILA FIRE DEPARTMENZ, Please call: 575-4407, and give this job No. 1 `I and exact address for shut. down Q11 restoration approvafj,1 CONTRACT NAME: Riverton Terrace 14410 41st Avenue South Tukwila WA 98168 CONTRACT WITH: W.G. Clark Construction 401 Aurora Ave. N Seattle WA 98109 Project Manager Eric Peterson Phone: 206-624-5244 Fax: 206-682-7126 PAID MAY 11 2007 Tukwila Fire y}-250?(,_ ",-6( VICINITY MAP SCALE: N. T. S. SITE PLAN AND DETAILS Fire Systems West 219 Frontage Road North, Suite B Pacific, WA. 98047 (253) 833-1248 Fax: (253) 735-0113 WA CL# FIRESWI 140B1 Q.C. FAB BY: Q.C. INSTALL BY: DESIGNER DATE JOB NUMBER SHEET Steven Huff 04/30/07 2-16-6109 1 of 5 ELEVATOR MACHINER3 H ( 2 ) STAIR #2 0 Q. EXISTING STANDPIPE FIG. 126 / LAG BOLT WOOD TJI/ROOF TRUSS HANGER NO. 510 HANGER TYPE W NTS BEDROOM LIVING ROOM -4 110 I CLOSET ► BATH ROOM KITCHEN LIVING ROOM 10s ENTRY , � I� �\ (2" ®-4 o ENTRY (6) BEDROOM 1 l 7 / BEDROOM "4LOSET KITCHEN BATHROO 1 KITCHEN cJ CLOSET BEDROOM 1 WW CO ._� o ENTRY d 1 1 d 1-- 111 44 LIVING ROOM ► ENTRY 109 LIVING ROOM KITCHEN ► CLOSET BEDROOM 011.0 CLOSET LIVING ROOM O ATH R&D Or ® KITCHEN ( ;-106 (9) LIVING ROOM ,[:10 104 °*y ENTRY 0 jJ1 ENTRY J I J.. BEDROOM CLOSETi KITCHEN ► BATNRoar COORIDOR 101 c BATHROO [.CLOSET KITCHEN BEDROOM J - , W -!0 O ENTRY ENTRY 107 LIVING ROOM FIRST FLOOR SPRINKLER PLAN SCALE: 1/8" = 1'-0" HANGER NO. 511 HANGER TYPE X NTS FIG. 126 LAG BOLT WOOD JOIST OR COMPOSITE WOOD JOIST \"NO BLOCK" HANGER HANGER NO. 514 HANGER TYPE Y NTS 105 LIVING ROOM 1"5xTIkDAPT%" KITCHENS �� ) BATHROOM ( 112 1 /- -1,;,113 010g1j MAINTENANCE & STORAGE 107 1 �yy �_ 75 3.O (.0q 0q 110 � 94(\e =_., 4 iNA ti 13-8 1• 2.0'1 RISER - 'OM ) 114„ ,4t -f 4 etN 111 ) 21 Ir. 3) P;(10-11 1;1) LAUNRY ;7/24{moms mm-mmom-mmor 1'O PIPE TO FLOOR DRAIN IN LAUNDRY: WM- .CLOSET BEDROOM 33 ) D -0 114 .••••"-'1 25 104; •. 1',i 26/ /;106> T ' AP -_ 1 COMMU ITY ROOM 16 -® ;100) mow - 105) I (102)0' X30 ;) 109 , ATC�R . , /// j TAIR #1 r-- ELEVATOR CONTROL MATERIAL LIST Item Number Quantity Size Description Manufacturer 1 1 1" Butterball Valve, TxT WI Tamper Switch Victaulic 2 1 1" Threaded Plug . . Generic E ELEVATOR CONTROL DETAIL SCALE: NTS J LOOKING WEST Riser Tag Design Basis Occupancy: Total Sprinklers: Number Of Sprinklers Calculated: K -Factor: Orifice Size: Design Density: Average Density: Area of Application: Demand at Base Of Riser or Point Of Connection Total Demand Flow(gpm): Pressure(psi): Ordinary Group II - Maint. & Storage 88 ' 5 5.6 0.5 0.208 pm/ft' 0.24g pm/ft2 900.00ft2 (Actual 364.69ft2) 87.19 28.80 NOTE: PER NFPA #13, SECTION 8.15.5.2, ELEVATOR DOES NOT REQUIRE AUTOMATIC SPRINKLER PROTECTION UE TO UTILIZATION OF FIRE RATED SHAFT CONSTRUCTION AND NON-COMBUSTIBLE HYDRAULIC FLUID EXISTING STANDPIPE AT LANDING ElevwJ�� Shad+ c% wok �;� i0 5c sp.r�k4► wlSvperwk� teh%I XTADAPT rN EXPRESS DRAIN OUTLET PIPBTO SAFE LOCATION OUTSIDE �G OFFICE' 2l r106Aj I .,.... Riser Tag Design Basis Occupancy: Total Sprinklers: Number Of Sprinklers Calculated: K -Factor: Orifice Size: Design Density: Average Density: Area of Application: Demand at Base Of Riser or Point Of Connection Total Demand Flow(gpm): Pressure(psi): Light Hazard - Community Room 88 8 5.6 0.5 0.10gpm/ft' 0.16g p m/ft2 900.00ft2 (Actual 879.67ft2) 138.83 59.06 HANGERS - PIPE HANGERS SHALL BE SIZED, SPACED AND INSTALLED AS REQUIRED BY NFPA STANDARDS - NO OTHER PIPING AND/OR DEVICES ARE TO BE ATTACHED TO THE SPRINKLER PIPE HANGER SYSTEM UNLESS THE HANGER HAS BEEN SPECIFICALLY DESIGNED FOR THE ADDITIONAL LOADING. - THIS CONTRACT DOES NOT INCLUDE ANY MATERIAL OR DEVICES TO IMPROVE THE STRUCTURAL STRENGTH OF THE BUILDING TO ENABLE IT TO CARRY THE LOAD OF THE FIRE PROTECTION SYSTEM. - HANGER ASSEMBLIES MUST BE SPACED 6" FROM SPRINKLER HEAD - SEE DETAILS ON THIS SHEET FOR THE SPECIFIC HANGER ASSEMBLIES USED FOR THIS INSTALLATION. 1,co'7 NFPA 13, 2082 -Edition Table 9.2.2.1MMAXIMUM DISTANCE BETWEEN HANGERS (ft- in) ) PIPE TYPE CPVC NOMINAL PIPE SIZE ( IN. ) 3/4 1 1 1/4 1 1/2 2 2 1/2 3 5-6 6-0 6-6 7-0 8-0 9-0 10-0 SPRINKLER SPACING TABLE - STANDARD RECESSED SIDEWALL SIDEWALL VIKING VK305, 5.6K PIPE SIZED CALC'D USING THIS SPACING SPRINKLER SPACING MAX. SPRINKLER LOCATION MAX (FROM SIDE WALLS) SPRINKLER DESIGN DISCHARGE SINGLE SPRK. TWO OR MORE SPRKS PLAN SYMBOL FEET FEET GPM 0 PSI GPM @ PSI U.S 14' x 14' 7' 19.6 012,25 5.6 SPRINKLER SPACING TABLE - RESIDENTIAL SIDEWALL RESIDENTIAL SIDEWALL VIKING VK450, 4.1K MAX 2" IN 12" RISE PIPE SIZED CALC'D USING THIS SPACING SPRINKLER SPACING MAX. SPRINKLER LOCATION MAX (FROM SIDE WALLS) SPRINKLER DESIGN DISCHARGE SINGLE SPRK. TWO OR MORE SPRKS PLAN SYMBOL FEET FEET GPM @ PSI GPM @ PSI U,S. 16'x 16' B' _• 18.0 018.4 4.1 SPRINKLER SPACING TABLE - RESIDENTIAL PENDENT PENDENT VIKING VK425, 4.1K PIPE SIZED CALC'D USING THIS SPACING SPRINKLER SPACING MAX. SPRINKLER LOCATION MAX (FROM SIDE WALLS) SPRINKLER DESIGN DISCHARGE SINGLE SPRK. TWO OR MORE SPRKS PLAN SYMBOL FEET FEET GPM v, PSI GPM @ P51 U.S. 14'x14' 7' 16.0@15.2 4.1 FIRST FLOOR HANGER LEGEND SPRINKLER HEADS REVISIONS GENERAL NOTES DESIGN CRITERIA AND NOTES A B C D E F G H U -HOOK L L -ROD SYM TYPE MFG MODEL ORIFICE THREAD TEMP FINISH CANOPY QTY MK DATE BY DESCRIPTION SUPER SCREW M WASHER PLATE 0 SSU VIKING VK300 1/2"/5.6K 1/2" 155* BRASS NONE 10 A CONCRETE INSERT N ► RES. HSW VIKING VK450 1/2" / 4.1K 1/2" 155* WHITE WHITE 60 A TOP BEAM CLAMP P POWDER DRIVEN STUD D HSW VIKING VK305 1/2"/5.6K 1/2" 155* CHROME CHROME 2 A R WEDGE ANCHOR • RES. CONC. VIKING VK425 1/2" / 4.1K 1/2" 155" BRASS WHITE 11 A HDI -P T TRAPEZE REC. CONC. VIKING VK404 1/2" / 5.6K 1/2" 155* BRASS WHITE 5 A CEILING FLANGE U APPROVALS REQUIRED: DISTRIBUTION: SIDE BEAM BRACKET W AUTHORITY City of Tukwila 3 J K SIDEWINDER X OWNER / ARCHITECT OWNER / ARCHITECT 3 SHORT CLIP Y TOTAL 88 FIRE SYSTEMS WEST 2 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UNDERWRITERS APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISER & DIMENSIONS SHOWN THUSLY (1'-6") WHICH ARE END TO END. 3.EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA #13. 4. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA #13. 5.PIPING SHALL BE IN ACCORDANCE WITH NFPA#13. 6. JOINING OF PIPE AND FITTINGS, THREADED AND WELDED SHALL BE IN ACCORDANCE WITH NFPA #13. 7. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY WET PIPE SPRINKLER SYSTEM. 8. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER OR HIS STRUCTURAL REPRESENTATIVE. 1. ALL TREE BRANCHLINE PIPING TO BE SCHEDULE 40 JOINED W/ CAST IRON THREADED FITTI NGS. 2. ALL HANGERS AT CONCRETE SLABS TO BE HILTI HDI -P (UNO). 3. ALL PENDENT HEADS TO BE LOCATED IN CENTER LINE OF TILES IN 2-0 DIRECTION - NO CLOSER THAN 4" TO GRID. 4. PIPING SHALL BE INSTALLED IN ACCORDNCE WITH NFPA 13. 5. ALL CPVC PIPE SHOWN WITHOUT PIPE LENGTHS. 6. ALL CPVC PIPING TO BE 1" UNO. UNLESS NOTED 7. WHEN INSULATION IS INSTALLED BY OTHERS THERE MUST NOT BE ANY PLACED BETWEEN THE PIPING AND THE HEATED AREA. INSULATION MUST RUN BEHIND PIPING TO PROTECT FROM FREEZING. 8. AREAS WITH CROSSHATCH DO NOT REQUIRE SPRINKLER PROTECTION PER NFPA 13 SECTION 8. 9. PIPE TO BE HUNG WITH HANGERS AND SPACING PER NFPA 13 AND CPVC HANGER DETAILS AND SPACING CHART SHOWN ON THIS SHEET. 10. ALL SPRINKLERS IN DWELLING UNIT CLOSETS SHALL HAVE HEAD GUARDS INSTALLED. BUILDING PERMIT # CONTRACT NAME: Riverton Terrace 14410 41st Avenue South Tukwila WA 98168 CONTRACT WITH: W.G. Cla k Construction 401 Aurora Ave. N Seattle WA 98109 Project Manager Eric Peterson Phone: 206-624-5244 Fax: 206-682-7126 Fire Systems West 219 Frontage Road North, Suite B Pacific, WA. 98047 (253) 833-1248 Fax: (253) 735-0113 WA CL# FIRESWI 140B1 Q.C. FAB BY: Q.C. INSTALL BY: DESIGNER DATE JOB NUMBER SHEET Steven Huff 04/30/07 2-16-6109 2 of 5 DATE:04/30/07 TIME:10:18 50 Second Floo STAIR #2 -t CO .I • B TOB 45* !-- - ----11/4 114 11 ' 3 ( 4� C8) LIVING ROOM BEDROOM CLOSET ®► 211 ATHROOM KITCHEN CUT IN FEED TO EXISTINGpUSTANDPIPE SHEET 5 of 15 r-� FIG. 126 / LAG BOLT WOOD TJI/ROOF TRUSS HANGER NO. 510 HANGER TYPE W NTS a! WA LIVING ROOM 209 _-J ENTRY rri ENTRY BEDROOM CLOSET ; O KITCHEN BATHROO 4 - f CLOSED KITCHEN BEDROOM ) I_= O to ENTRYU I E NTRY 210 ® LIVING ROOM 208_ LIVING ROOM 21.0 KITCHEN® (CLOSET BEDROOM I WA I \ 1 BEDROOM 0 LIVING ROOM CLOSE EATH IRAAM - KITCHEN L 1,4 I. 1 BATH R (CLOSET 4 __-.18.8 KITCHEN 1 BEDROOM 1'4 11.; 207 ENTRY COOR!DOR 2Q1 LIVING ROOM 205 _ f Icn ENTRY 0 U ENTRY L206 .4 LIVING ROOM SECOND FLOOR SPRINKLER PLAN HANGER NO. 511 HANGER TYPE X NTS FIG_126 LAG BOLT WOOD JOIST OR COMPOSITE WOOD JOIST 1 1/2" \"NO BLOCK" HANGER HANGER NO. 514 HANGER TYPE Y NTS 204 LIVING ROOM I_. KITCHEN ENTRY 1',4 4 21.0 9 ) 10 BEDROOM 4 CLOSET l �BA]HROOM KITCHEN I). --4-4,-I) LIVING ROOM 203 12 ) K /i 13 4" CONTRM! L VALVE (2x) 4 -1,- -4J -BATHROOM ® CLOSET BEDROOM 42 BATH KITCHEN CLOSET BEDROOM i0 LLI ENTRY J I J ENTRY ®O U, 202 ® LIVING ROOM L201 LIVING ROOM 21.0 KITCHEN, TI ROOIV 4 L©SET Ir-_p+� BEDROOM i/ 7. ATO STAIR #1 16 j CUT IN FEED TO EXISTING TANDPI"E SEE NORTH DETAIL SHEET 5 of 5 9 C NOTE: PER NFPA #13 SECTION 8.15.5.2, ELEVATOR DOES NOT REQUIRE AUTOMATIC SPRINKLER PROTECTION UE TO UTILIZATION OF FIRE RATED SHAFT CONSTRUCTION AND NON-COMBUSTIBLE HYDRAULIC FLUID 4" TO STANDPIPES FLOOR CONTROL MATERIAL LIST Item Number Quantity Size Description, Manufacturer 1 1 114" Ball Valve, TxT W1 Tamper Switch Generic 2 1 '4" Pressure Gauge Genetic 3 1 11" Potter VSR-SF Waterftow Swit t Potter Roemer 4 1 1" AGF 1000 Test and Drain AGF FLOOR CONTROL PIPING DETAIL J SCALE: 1/2" = 1' - 0" LOOKING NORTH HANGERS - PIPE HANGERS SHALL BE SIZED, SPACED AND INSTALLED AS REQUIRED BY NFPA STANDARDS - NO OTHER PIPING AND/OR DEVICES ARE TO BE ATTACHED TO THE SPRINKLER PIPE HANGER SYSTEM UNLESS THE HANGER HAS BEEN SPECIFICALLY DESIGNED FOR THE ADDITIONAL LOADING. - THIS CONTRACT DOES NOT INCLUDE ANY MATERIAL OR DEVICES TO IMPROVE THE STRUCTURAL STRENGTH OF THE BUILDING TO ENABLE IT TO CARRY THE LOAD OF THE FIRE PROTECTION SYSTEM. - HANGER ASSEMBLIES MUST BE SPACED 6" FROM SPRINKLER HEAD - SEE DETAILS ON THIS SHEET FOR THE SPECIFIC HANGER ASSEMBLIES USED FOR THIS INSTALLATION. 7.014 NFPA 13, 2%2 -Edition Table 9.2.2.11VAXIMUM DISTANCE BETWEEN HANGERS (ft - in) PIPE TYPE CPVC NOMINAL PIPE SIZE ( IN. ) 3/4 1 1 1/4 1 1/2 2 2 1/2 3 5-6 6-0 6-6 7-0 8-0 9-0 10-0 EXPIRES 08/101 .1 SPRINKLER SPACING TABLE - RESIDENTIAL SIDEWALL RESIDENTIAL SIDEWALL VIKING VK450, 4.2K MAX 2" IN 12" RISE PIPE SIZED CALC'D USING THIS SPACING SPRINKLER SPACING MAX. SPRINKLER LOCATION MAX (FROM SIDE WALLS) SPRINKLER DESIGN DISCHARGE SINGLE SPRK. TWO OR MORE SPRKS PLAN SYMBOL FEET FEET GPM @ PSI GPM @ PSI U.S. Pi 16' x 16' B' 18.0 118.4 -� 4.2 SPRINKLER SPACING TABLE - RESIDENTIAL PENDENT CONCEALED PENDENT VIKING VK425, 4.1K PIPE SIZED CALC'D USING THIS SPACING SPRINKLER SPACING MAX. SPRINKLER LOCATION MAX (FROM SIDE WALLS) SPRINKLER DESIGN DISCHARGE SINGLE SPRK, TWO OR MORE SPRKS PLAN SYMBOL FEET FEET GPM @PSI GPM @ PSI U.S. 14'x14' 7' 16.0@15.2 - 4.1 SECOND FLOOR HANGER LEGEND SPRINKLER HEADS REVISIONS GENERAL NOTES DESIGN CRITERIA AND NOTES A U -HOOK L L -ROD SYM TYPE MFG MODEL ORIFICE THREAD TEMP FINISH CANOPY QTY MK DATE BY DESCRIPTION B SUPER SCREW M WASHER PLATE • RES. PEND VIKING VK425 1/T / 4.1K 1/2" 155* BRASS WHITE 13 A C CONCRETE INSERT N RES. HSW VIKING VK450 1/2" / 4.2K 1/2" 155* WHITE WHITE 77 A D TOP BEAM CLAMP P POWDER DRIVEN STUD DRY HSW VIKING VK182 1/2"/5.61< 1/2" 155* CHROME CHROME 1 A E F G H J HDI -P CEILING FLANGE R WEDGE ANCHOR TRAPEZE HSW VIKING VK305 1/2" / 5.6K 1/2" 155* CHROME CHROME 4 A A SIDE BEAM BRACKET SIDEWINDER K SHORT CLIP w X APPROVALS REQUIRED: AUTHORITY OWNER / ARCHITECT DISTRIBUTION: City of Tukwila OWNER / ARCHITECT Y TOTAL 95 FIRE SYSTEMS WEST 2 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UNDERWRITERS APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISER & DIMENSIONS SHOWN THUSLY (1'-6") WHICH ARE END TO END. 3.EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA#13. 4. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA #13. 5.PIPING SHALL BE IN ACCORDANCE WITH NFPA #13. 6. JOINING OF PIPE AND FITTINGS, THREADED AND WELDED SHALL BE IN ACCORDANCE WITH NFPA#13. 7. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY WET PIPE SPRINKLER SYSTEM. 8. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER OR HIS STRUCTURAL REPRESENTATIVE. 1. ALL TREE BRANCHLINE PIPING TO BE SCHEDULE 40 JOINED W/ CAST IRON THREADED FITTINGS. 2. ALL HANGERS AT CONCRETE SLABS TO BE HILTI HDI -P (UNO). 3. ALL PENDENT HEADS TO BE LOCATED IN CENTER LINE OF TILES IN 2-0 DIRECTION - NO CLOSER THAN 4" TO GRID. 4. PIPING SHALL BE INSTALLED IN ACCORDNCE WITH NFPA 13. 5. ALL CPVC PIPE SHOWN WITHOUT PIPE LENGTHS. 6. ALL CPVC PIPING TO BE 1" UNO. UNLESS NOTED 7. WHEN INSULATION IS INSTALLED BY OTHERS THERE MUST NOT BE ANY PLACED BETWEEN THE PIPING AND THE HEATED AREA. INSULATION MUST RUN BEHIND PIPING TO PROTECT FROM FREEZING. 8. AREAS WITH CROSSHATCH DO NOT REQUIRE SPRINKLER PROTECTION PER NFPA 13 SECTION 8. 9. PIPE TO BE HUNG WITH HANGERS AND SPACING PER NFPA 13 AND CPVC HANGER DETAILS AND SPACING CHART SHOWN ON THIS SHEET. 10. ALL SPRINKLERS IN DWELLING UNIT CLOSETS SHALL HAVE HEAD GUARDS INSTALLED. BUILDING PERMIT # CONTRACT NAME: Riverton Terrace 14410 41st Avenue South Tukwila WA 98168 CONTRACT WITH: W.G. Clark Construction 401 Aurora Ave. N Seattle WA 98109 Project Manager Eric Peterson Phone: 206-624-5244 Fax: 206-682-7126 Fire Systems West 219 Frontage Road North, Suite B Pacific, WA. 98047 (253) 833-1248 Fax: (253) 735-0113 WA CL# FIRESWI 140B1 Q.C. FAB BY: Q.C. INSTALL BY: DESIGNER DATE JOB NUMBER SHEET Steven Huff 04/30/07 2-16-6109 3 of 5 N W 2 1= r- 0 0 I:LI 0 LL 1- X 0 N a}i 0 a) E ch w J u- A B C D o) FIG. 126 / LAG BOLT WOOD TJI/ROOF TRUSS HANGER NO. 510 HANGER TYPE W U -HOOK NTS HANGER LEGEND Riser Tag Design Basis Occupancy: Total Sprinklers: Number Of Sprinklers Calculated: K -Factor: Orifice Size: Design Density: Average Density: Area of Application: Demand at Base Of Riser or Point Of Connection Total Demand Flow(gpm): Pressure(psi): HANGER NO.511 HANGER TYPE X NTS FIG. 126 LAG BOLT Light Hazard - Corridor 91 5 4.2 0.5 0.10gpm/ft' 0.24g pm/ft' 1500.00ft' (Actual 375.39ft') 91.96 5249- _-- _ WOOD JOIST OR COMPOSITE WOOD JOIST 11/2' 0 0 LIVING ROOM BEDROOM STAIR #2 t..',: . 4 310 LOSE ATH ROOM KITCHEN _ DN 17- //® 1 / (310• LIVING ROOM 308 T •' 'N 10_1 ENTRY I. [_ 1 BEDROOM i. 4CLOSET I KITCHEN BATHROO 4t) $2 (1p i ITCHEN (� 05-2) , ',CLOSET": I BEDROOM (300 lji ®/ LIVING ROOM \10 \ (301) f 1-- 1 J, ENTRY .4 ENTRY ; 302 ) 311 MINN 111101111H/11111-11•1111016-111111111111-41111114-111•10ft 309 LIVING ROOM KITCHEN104_, (_) 1CLOSET BEDROOM Riser Tag Design Basis Occupancy: Total Sprinklers: Number Of Sprinklers Calculated: K -Factor: Orifice Size: Design Density: Average Density: Area of Application: Demand at Base Of Riser'or Point Of Connection Total Demand Flow(gpm): Pressure(psi): Residential - 4 Heads in Unit 91 4 4.2 0.5 0.10gpm/ft' 0.22gpm/ft' 900.00ft' (Actual 364.74ft2) 78.70 67.31 \'NO BLOCK" HANGER HANGER NO. 514 HANGER TYPE Y NTS (;) BEDROOM j CLOSET II► ) �EATHROQM' A LI 312j P( 0 ®I BATHROOM I r (_71 LIVING ROOM 1 KITCHEN KITCHEN CLOSE* BEDROOM LIVING ROOM L306 304 ENTR Ii I 1% ENTRY BEDROOM CLOSET: ) BATHROOM KITCHEN 4- C5) CI -6) 302 OORIDOR 301 A 314.' Ert"p-� KITCHEN E;;TRY J U ENTRY =7 307 LIVING ROOM THIRD FLOOR SPRINKLER PLAN SCALE: 1/8" = 1'-0" 1 305 LIVING ROOM „ (.4 t ROOF BELOW CLOSET et KITCHEN 1'4 l'+4 BATHROOM 'CLOSET BATHR(' BEDROOM 1 KITCHEN C CLOSET>' BEDROOM .4J IIS A 1'i 302 1'i ENTRY I U ENTRY 303 LIVING ROOM C:0 ROOM S RVICE% 313 ti:z • *% � // STAIR #1 JT / / KITCHEN .441) BATHROOM 4LOSET 1 301 1 LIVING ROOM BEDROOM C) D NOTE: PER NFPA #13, SECTION 8.15.5.2 ELEVATOR DOES NOT REQUIRE AUTOMATIC SPRINKLER PROTECTION UUE TO UTILIZATION OF FIRE RATED SHAFT CONSTRUCTION AND NON-COMBUSTIBLE HYDRAULIC FLUID 114" TO SPRINKLERS FLOOR CONTROL MATERIAL LIST Item Number Quantity Size Description Manufacturer 1 1 1'+." Ball Valve, TxT W! Tamper Switch Generic 2 1 W Pressure Gauge Generic 3 1 11,:" Potter VSR-SF Waterflow Switch Potter Roemer 4 1 1" AGF 1000 Test and Drain AGF FLOOR CONTROL PIPING DETAIL SCALE: 1/2" = 1'-0" HANGERS - PIPE HANGERS SHALL BE SIZED, SPACED AND INSTALLED AS REQUIRED BY NFPA STANDARDS - NO OTHER PIPING AND/OR DEVICES ARE TO BE ATTACHED TO THE SPRINKLER PIPE HANGER SYSTEM UNLESS THE HANGER HAS BEEN SPECIFICALLY DESIGNED FOR THE ADDITIONAL LOADING. - THIS CONTRACT DOES NOT INCLUDE ANY MATERIAL OR DEVICES TO IMPROVE THE STRUCTURAL STRENGTH OF THE BUILDING TO ENABLE IT TO CARRY THE LOAD OF THE FIRE PROTECTION SYSTEM. - HANGER ASSEMBLIES MUST BE SPACED 6" FROM SPRINKLER HEAD - SEE DETAILS ON THS SHEET FOR THE SPECIFIC HANGER ASSEMBLIES USED FOR THIS INSTALLATION. ebb% NFPA 13, 266-2 Edition Table 9.2.2.1 MAXIMUM DISTANCE BETWEEN HANGERS (ft- in) PIPE TYPE CPVC NOMINAL PIPE SIZE ( IN. ) 3/4 1 1 1/4 1 1/2 2 2 1/2 3 5-6 6-0 6-6 7-0 8-0 9-0 10-0 LOOKING NORTH SPRINKLER SPACING TABLE - STANDARD RECESSED SIDEWALL SIDEWALL VIKING VK305, 5.6K PIPE SIZED CALC'D USING THIS SPACING SPRINKLER SPACING MAX. SPRINKLER LOCATION MAX (FROM SIDE WALLS) SPRINKLER DESIGN DISCHARGE SINGLE SPRK. TWO OR MORE SPRKS PLAN SYMBOL FEET FEET GPM @ PSI GPM _ PSI U.S. I> 14'x14' 7' 19.6@1225 5.6 SPRINKLER SPACING TABLE - RESIDENTIAL SIDEWALL RESIDENTIAL SIDEWALL VIKING VK450, 4.1K MAX 2" IN 12" RISE PIPE SIZED CALC'D USING THIS SPACING SPRINKLER SPACING MAX. SPRINKLER LOCATION MAX (FROM SIDE WALLS) SPRINKLER DESIGN DISCHARGE SINGLE SPRK. TWO OR MORE SPRKS PLAN SYMBOL FEET FEET GPM C+ PSI GPM C& P51 U.S. DO 16'x16' 8' 18A@18.4 4.1 THIRD FLOOR SPRINKLER HEADS REVISIONS GENERAL NOTES DESIGN CRITERIA AND NOTES L L -ROD SYM TYPE MFG MODEL ORIFICE THREAD TEMP FINISH CANOPY QTY MK DATE BY DESCRIPTION SUPER SCREW M WASHER PLATE RES. HSW VIKING VK450 1/2"/4.1K 1/2" 155* WHITE WHITE 88 CONCRETE INSERT N HSW VIKING VK305 1/2"/5.6K 1/2" 155* CHROME CHROME 4 TOP BEAM CLAMP P POWDER DRIVEN STUD F G H J HDI -P CEILING FLANGE SIDE BEAM BRACKET SIDEWINDER R T W X WEDGE ANCHOR TRAPEZE A A A A A APPROVALS REQUIRED: AUTHORITY OWNER / ARCHITECT DISTRIBUTION: City of Tukwila 3 OWNER / ARCHITECT 3 K SHORT CLIP Y TOTAL 91 FIRE SYSTEMS WEST 2 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UNDERWRITERS APPROVED. 2. PIPING DIMENSIONS ARE CENTER TOCENTER EXCEPT RISER & DIMENSIONS SHOWN THUSLY (1'-6") WHICH ARE END TO END. 3.EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA #13. 4. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA #13. 5.PIPING SHALL BE IN ACCORDANCE WITH NFPA #13. 6. JOINING OF PIPE AND FITTINGS, THREADED AND WELDED SHALL BE IN ACCORDANCE WITH NFPA#13. 7. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY WET PIPE SPRINKLER SYSTEM. 8. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER OR HIS STRUCTURAL REPRESENTATIVE. 1. ALL TREE BRANCHLINE PIPING TO BE SCHEDULE 40 JOINED W/CAST IRON THREADED FITTINGS. 2. ALL HANGERS AT CONCRETE SLABS TO BE HILTI HDI -P (UNO). 3. ALL PENDENT HEADS TO BE LOCATED IN CENTER LINE OF TILES IN 2-0 DIRECTION - NO CLOSER THAN 4" TO GRID. 4. PIPING SHALL BE INSTALLED IN ACCORDNCE WITH NFPA 13. 5. ALL CPVC PIPE SHOWN WITHOUT PIPE LENGTHS. 6. ALL CPVC PIPING TO BE 1" UNO. UNLESS NOTED 7. WHEN INSULATION I5 INSTALLED BY OTHERS THERE MUST NOT BE ANY PLACED BETWEEN THE PIPING AND THE HEATED AREA. INSULATION MUST RUN BEHIND PIPING TO PROTECT FROM FREEZING. 8. AREAS WITH CROSSHATCH DO NOT REQUIRE SPRINKLER PROTECTION PER NFPA 13 SECTION 8. 9. PIPE TO BE HUNG WITH HANGERS AND SPACING PER NFPA 13 AND CPVC HANGER DETAILS AND SPACING CHART SHOWN ON THIS SHEET. 10. ALL SPRINKLERS IN DWELLING UNIT CLOSETS SHALL HAVE HEAD GUARDS INSTALLED. BUILDING PERMIT # CONTRACT NAME: Riverton Terrace 14410 41st Avenue South Tukwila WA 98168 CONTRACT WITH: W.G. Clark Construction 401 Aurora Ave. N Seattle WA 98109 Project Manager Eric Peterson Phone: 206-624-5244 Fax: 206-682-7126 Fire Systems West 219 Frontage Road North, Suite B Pacific, WA. 98047 (253) 833-1248 Fax: (253) 735-0113 WA CL# FIRESWI 140B1 Q.C. FAB BY: Q.C. INSTALL BY: DESIGNER DATE JOB NUMBER SHEET Steven Huff 04/30/07 2-16-6109 4 of 5 CD M M 0-6 T R m ROOF LEVEL CUT IN NEW BUTTERFLY VALVE WI TAMPER TO PREVENT FREEZING OF HOSE VALVES ON ROOF THIRD FLOOR 1-6 CUT NEW SUPPLY FEED INTO EXISTING STAN3PIPE- REMOVE EXISTING FDC ANITPIPE PLUG EXISTING OUTLET `4 v 0-61A NORTH STANDPIPE TO RISER SECOND FLOOR 0 FIRST FLOOR SCALE: 1/2" = 11-0" LOOKING SOUTH 4 NOTE: EXISTING CLASS I DRY STANDPIPES TO BE CONVERTED TO CLASS I WET ALL EXISTING PIPE IS SHOWN DASHED ROOF LEVEL REMOVE EXISTING PIPE TO ROOF AND PLUG EXISTING OUTLET THIRD FLOOR TO RISER CUT NEW SUPPLY FEED INTO EXISTING STANDPIPE SECOND FLOOR FIRST FLOOR SOUTH STANDPIPE REMOVE EXISTING FDC AND PIPE PLUG EXISTING OUTLET 0 a) 4 R m 0-6 SCALE: 1/2" = 11-0" LOOKING EAST STANDPIPES HANGER LEGEND SPRINKLER HEADS REVISIONS GENERAL NOTES DESIGN CRITERIA AND NOTES A U -HOOK L L -ROD SYM TYPE MFG MODEL ORIFICE THREAD TEMP FINISH CANOPY QTY MK DATE BY DESCRIPTION B SUPER SCREW M WASHER PLATE A C CONCRETE INSERT N A D TOP BEAM CLAMP P POWDER DRIVEN STUD A E R WEDGE ANCHOR A F HDI -P T TRAPEZE A G CEILING FLANGE U APPROVALS REQUIRED: DISTRIBUTION: H SIDE BEAM BRACKET W AUTHORITY City of Tukwila 3 J SIDEWINDER X OWNER / ARCHITECT OWNER / ARCHITECT 3 K SHORT CLIP Y TOTAL FIRE SYSTEMS WEST 2 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UNDERWRITERS APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISER & DIMENSIONS SHOWN THUSLY (11-6") WHICH ARE END TO END. 3.EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA #13. 4. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA #13. 5.PIPING SHALL BE IN ACCORDANCE WITH NFPA #13. 6. JOINING OF PIPE AND FITTINGS, THREADED AND WELDED SHALL BE IN ACCORDANCE WITH NFPA #13. 7. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY WET PIPE SPRINKLER SYSTEM. 8. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER OR HIS STRUCTURAL REPRESENTATIVE. 1. ALL TREE BRANCHLINE PIPING TO BE SCHEDULE 40 JOINED W/ CAST IRON THREADED FITTINGS. 2. ALL HANGERS AT CONCRETE SLABS TO BE HILTI HDI -P (UNO). 3. ALL PENDENT HEADS TO BE LOCATED IN CENTER LINE OF TILES IN 2-0 DIRECTION - NO CLOSER THAN 4" TO GRID. 4. PIPING SHALL BE INSTALLED IN ACCORDNCE WITH NFPA 13R. 5. ALL CPVC PIPE SHOWN WITHOUT PIPE LENGTHS. 6. ALL CPVC PIPING TO BE 1" UNO. UNLESS NOTED 7. WHEN INSULATION IS INSTALLED BY OTHERS THERE MUST NOT BE ANY PLACED BETWEEN THE PIPING AND THE HEATED AREA. INSULATION MUST RUN BEHIND PIPING TO PROTECT FROM FREEZING. 8. AREAS WITH CROSSHATCH DO NOT REQUIRE SPRINKLER PROTECTION PER NFPA 13 SECTION 8. 9. PIPE TO BE HUNG WITH HANGERS AND SPACING PER NFPA 13 AND CPVC HANGER DETAILS AND SPACING CHART SHOWN ON THIS SHEET. BUILDING PERMIT # CONTRACT NAME: Riverton Terrace 14410 41st Avenue South Tukwila WA 98168 CONTRACT WITH: W.G. Clark Construction 401 Aurora Ave. N Seattle WA 98109 Project Manager Eric Peterson Phone: 206-624-5244 Fax: 206-682-7126 Fire Systems West 219 Frontage Road North, Suite B y Pacific, WA. 98047 (253) 833-1248 Fax: (253) 735-0113 WA CL# FIRESWI 140B1 Q.C. FAB BY: Q.C. INSTALL BY: DESIGNER DATE JOB NUMBER SHEET Steven Huff 04/27/07 2-16-6109 5 of 5 / E.PTE Without Comments As Noted In Red Per The Attached Lector These plans have been reviewed by The Tukwila Fire Prevention Bureau tor conformance with current city standards. Acceptance is -uhj es t to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings atter this date will void this,acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire, Prevention Bureau. Date: I b/. 1(rgp7 By: 1.1112101•111394^1.011.IIIVILCZA102052.03=1101IVAIMI.nr. 1 0.40 1,c a l o vttook 44te, ott at i t u, k) .-..1 y,s+a, t r a "F; ft. A-tq £ o %-4b t S;5.% -7—oleo r + (roov. CUA, -�e,.: ti ,) F - t? L WW•��iJ ��i�ci Val✓ Bemuse of incNla ecl demand and our is''(I; p2Ctors' schedules are booked 3-7 days ahead. Therefore, you ffl need to call 2O6 575-e 0 to schedule your Dnspect.ons a mininium.o? 48 hours in advance o fthe. date, you Want an inspec ono ok NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems, Failure of test will result in a Re -inspection Fee and termination of the testing. rUKWILA FIRE DEPARTMEr Please call: 575.4407 and give this job No. 07- F-a3`I and exact address for shuts down or restoration aoProvd BILL OF MATERIAL JOB NAME: KCHA RIVERTON TERRACE it jp it S.w"f Ssf y `;$$f 4Yi "kdf#� i£tSe '9"y '� S f ass{ral�tiY#Y�Sr`u��'aa�� FACP, ANALOG/ADDRESSABLE, 127 POINTS 1 5820XL 5860R LCD REMOTE ANNUNCIATOR, 80 CHAR., RED 1 5496 SIGNAL EXPANDER 1 SD505-APS SMOKE DET, PHOTO 85 SD505-6AB 6" BASE 85 SD500-AIM MONITOR MODULE 3 SD500-ARM RELAY MODULE 5 MP7-12 BATTERY, 12V-7AH 2 MP12-12 BATTERY, 12V-12AH 2 RSS-24MCW-FR WHEELOCK STROBE, WALL MOUNT, MULT1-CANDELA 30 NS-24MCW-FR WHEELOCK HORN/STROBE, WALL MOUNT, MULTI -CANDELA 6 AS-24MCC-FR WHEELOCK HORN/STROBE, CEILING MOUNT, MULT1-CANDELA 10 ASWP-2475W-FR WHEELOCK Weatherproof Horn/Strobe 1 WPBB-R WHEELOCK Hom/Strobe Weatherproof Backbox 1 WHEELOCK MIZ-24S—R JOB NAME: KCHA RIVERTON TERRACE - Change Order#1 �s #. � r� }���.� NS-24MCC—FR 3 5496 SIGNAL EXPANDER SD505-APS SMOKE DET, PHOTO -56 SD505-AHS ADDRESSABLE HEAT DET 62 SD505-6AB 6" BASE 6 SD505-PS PULL STATION, SGL ACTION 6 Kirkland GRAPHIC MAP 1 MR101/C Aux Relay 1 MP7-12 BATTERY, 12V-7AH 6 DHF1224C SEMIFLUSH MAGNETIC DOOR HOLDER (TRIED) 6 RSS-24MCW-FR WHEELOCK STROBE, WALL MOUNT, MULTI -CANDELA 1 NS-24MCW-FR WHEELOCK HORN/STROBE, WALL MOUNT, MULTI -CANDELA 61 �Z r � °,� alt' �� 4 3 j � � �St �'� z y� i ,;u £ us )y sty £�, ���errace THIS PAGE SHOULD BE 24" X 36". IF THIS SHEET IS ANY OTHER SIZE, ADJUST THE SCALE ACCORDINGLY ar men s 04, EVERGREEN FIRE AND SECURITY CERTIFIED BY UNDERWRITERS LABORATORIES GENERAL SYSTEM NOTES 1.) METALLIC RACEWAY SHALL BE USED IF REQUIRED BY CODE, SPECIFICATIONS, AND CONTRACT DOCUMENTS. 2.) ALL RACEWAYS MUST BE FREE OF MOISTURE. 3.) REFER TO EVERGREEN FIRE & SECURITY (EFA) FIRE DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE MOUNTING BOXES. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROPER INSTALLATION OF ALL DEVICES. 4.) AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE WIRING. 5.) UNRELATED (NON -FIRE) WIRING SHALL NOT BE IN THE SAME RACEWAY AS FIRE WIRING. 6.) ALL CONTRACTOR FIELD WIRING MUST ENTER TOP AND/OR BOTTOM RIGHT OF FIRE CONTROL PANEL ONLY, SEE DATA SHEET. Z) ALL FIRE WIRING SHALL TEST FREE OF OPENS, SHORTS, AND GROUNDS, 8.) ALL WIRES SHALL BE LABELED AND TAGGED. 9.) ALL WIRE SHALL MEET ALL APPLICABLE NATIONAL ELECTRICAL CODE ARTICLES FOR FIRE AND LOW VOLTAGE WIRING. FIRE SYSTEMS DESIGNED BY: EVERGREEN FIRE & SECURITY TACOMA, WASHINGTON FIRE SYSTEMS INSTALLED BY: EVERGREEN FIRE & SECURITY TACOMA, WASHINGTON FIRE SYSTEMS EQUIPMENT BY: EVERGREEN FIRE & SECURITY TACOMA, WASHINGTON *** THESE DRAWINGS 'DO'NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS. THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTOR OBLIGATION TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA, WIRE LEGEND X = 16-2 SLC CIRCUIT C = 14-2 INDICATING CKT D = 14-2 X 2 INDICATING CKT LOOP J = 16-4 ANNUNCIATOR CKT FIRE ALARM LEGEND SYMBOL DESCRIPTION MANUFACTURER PART # MOUNTING JOB DETAILS FIRE ALARM CONTROL PANEL SILENT KNIGHT 5820XL SELF CONTAINED FACP JCK O ADDRESSABLE SMOKE DETECTOR SILENT KNIGHT SD505—APS W/SD505-6AB BASE 4" OCT DEEP O ADDRESSABLE HEAT DETECTOR FT/ROR SILENT KNIGHT SD505—AHS W/SD505-6AB BASE 4" OCT DEEP CONVENTIONAL MANUAL PULL STATION SILENT KNIGHT PS—DA 4 SQ DEEP W/SINGLE GANG F HORN/STROBE WALL MOUNT XX - INDICATES DEVICE CANDELA SETTING /'E' INDICATES EXISTING DEVICE WHEELOCK NS-24MCW—FR 4 SQ DEEP W/SINGLE GANG XX STROBE XX - INDICATES DEVICE CANDELA SETTING /'E" INDICATES DUSTING DEVICE WHEELOCK RSS-24MCW—FR 4 SQ DEEP W/SINGLE GANG XX EWP HORN/STROBE WEATHERPROOF WHEELOCK ASWP-2475W—R WPBB—R EK MINI—HORN WHEELOCK MIZ-24S—R ILVI XX HORN/STROBE CEILING MOUNT XX - INDICATES DEVICE CANDELA SETTING /'E' INDICATES EXISTING DEVICE WHEELOCK NS-24MCC—FR 4 SQ DEEP W/SINGLE GANG Q JUNCTION BOX BY OTHERS BY OTHERS EOL END OF LINE DEVICE • POWER SUPPLY SILENT KNIGHT 5496 SELF CONTAINED NACP / / LEGAL NOTICE THE PLANS AND SPECIFICATIONS ARE COPYRIGHT MATERIALS AND ARE THE SOLE PROPERTY OF EVERGREEN FIRE AND SECURITY. ANY INFRINGEMENT ON THE COPYRIGHT OR UNAUTHORIZED USE OF THESE PLANS OR SPECIFICATIONS RENDERS THE USER LIABLE TO THE LAWS OF THE UNITED STATES. GENERAL NOTES / REVISIONS/NOTES JOB DETAILS CHANGE DATE APPRVD BY FOR SUBMITTAL 09/21/07 JCK AHJ CORRECTIONS/CHANGES 10/05/07 JCK BFM CHECKED BY: JCK CREATION DATE: 09/20/07 / JOB DETAILS DESIGNED BY: SAL DRAWN BY: BFM CHECKED BY: JCK CREATION DATE: 09/20/07 DRAWING SCALE: AS NOTED / JOB NAME RIVERTON TERRACE APARTMENTS MULTI -SITE UPGRADE PROJECT 14410 41st AVE. SOUTH TUKWILA, WASHINGTON 98168 SUBMITTED BY EVERGREEN FIRE AND SECURITY 3215 SOUTH 12TH STREET TACOMA, WA. 98405 253-627-3794 / SHEET NUMBER FAO.1 SHEET 1 OF 6 GENERAL NOTES: 1) ALL WIRE AND CONDUIT MUST BE INSTALLED IN ACCORDANCE WITH PLANS AND SPECIFICATION, AND MUST MEET ALL APPLICABLE CODES. 2) ALL WIRE AND CABLE MUST BE RATED FOR FIRE ALARM USER PER THE LATEST REVISIONS, OF THE NATIONAL ELECTRICAL CODE SECTION 760. THIS IS A POWER LIMITED FIRE ALARM SYSTEM, ALL CABLE MUST BE MARKED FPL, FPLR, OR FPLP. 3) ALL CONDUCTORS MUST TEST FREE OF GROUND BEFORE MAKING CONNECTION TO THE FIRE ALARM CONTROL PANEL. 4) TO RETAIN WARRANTEE, THE FIRE ALARM EQUIPMENT MUST BE POWERED UP UNDER THE DIRECTION OF A QUALIFIED MANUFACTURER'S TECHNICIAN. 5) THE LIFE SAFETY SYSTEM IS A COMPLETELY SUPERVISED SYSTEM. 6) INSTALLING INCLUD NG CHANGESR COORDINATE WERE CHANGESIRUNS AND OPERATION IN THE SYSTEM. MANUFACTURER SHALL NOT BE HELD RESPONSIBLE CAUSED BY THOSE CHANGES. 7) LIFE SAFETY AUDIBLE SHALL BE AUDIBLE THROUGHOUT THE SPACE AND HAVE A SOUND PRESSURE LEVEL NOT LESS THAN 15db ABOVE AMBIENT NOISE LEVEL MEASURED AT 4'-0" ABOVE FINISHED FLOOR. 8) SYSTEM SHALL BE CLASS "B" IN CONFIGURATION. 9) LOCATE ALL PULL STATION AND HORN/ STROBE UNITS AT SPECIFIED HIGH PER NFPA 72 AND ADA SEE DETAIL. 10) SMOKE DETECTOR LOCATION ARE FOR REFERENCE ONLY AND SHALL BE INSTALLED PER NFPA 72 11) ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ROUGH—IN INSTALLATION WITH THE FIRE ALARM CONTRACTOR 12) SMOKE DETECTORS IN CEILING MUST BE LESS THAN 15' FROM A WALL AND / OR NO FURTHER THAN 30' FROM EACH OTHER. 13) NO SMOKE DETECTOR SHALL BE LOCATED CLOSER THAN 36" TO ANY AIR REGISTER OR DIFFUSER 14) NO HEAT DETECTOR SHALL BE LOCATED CLOSER THAN 24" TO ANY AIR REGISTER OR DIFFUSER. 15) NO HEAT DETECTOR SHALL BE LOCATED CLOSER THAN 36" TO ANY PART OF ANY HEAT GENERATION DEVICE (FUSE, BOILERS, WATER HEATER, ETC..) IN MECHANICAL ROOMS. 16) NO HEAT DETECTOR SHALL BE LOCATED CLOSER THAN 18" TO ANY PART OF LIGHT FIXTURE. 17) INITIATION AND SIGNALING CIRCUITS ARE SEPARATE YET MAY BE RUN IN SAME CONDUIT 18) ALL CONDUCTORS SHALL BE LABELED BY ZONE AND ALL COLOR CODES SHALL MATCH 19) ALL CIRCUIT FEED AND RETURN'S SHALL BE SEPARATED BY A MINIMUM OF 1' WHEN INSTALLED VERTICALLY AND 4' WHEN INSTALLED HORIZONTALLY PER NFPA72 20) THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS, THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATION TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA. 21) METALLIC RACEWAY SHALL BE USED WHEN REQUIRED BY CODE, SPECIFICATIONS AND CONTRACT DOCUMENTS 22) ALL RACEWAYS MUST BE FREE OF MOISTURE. 23) ALL CIRCUIT FEED AND RETURN'S SHALL BE SEPARATED BY A MINIMUM OF 1' WHEN INSTALLED VERTICALLY AND 4' WHEN INSTALLED HORIZONTALLY PER NFPA72 24) REFER TO EVERGREEN FIRE & SECURITY (EFA) FIRE DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE MOUNTING BOXES. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROPER INSTALLATION OF ALL MOUNTING BOXES 25) AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE WIRING. 26) UNRELATED (NON—FIRE) WIRING SHALL NOT BE IN THE SAME RACEWAY AS FIRE WIRING. 27) ALL CONTRACTOR FIELD WIRING MUST ENTER TOP AND/OR SIDE OF FIRE CONTROL -- PANEL ONLY. SEE DATA SHEET. 28) ALL FIRE WIRING SHALL TEST FREE OF OPENS, SHORTS, AND GROUNDS. 29) ALL WIRES SHALL BE LABELED AND TAGGED. 30) ALL WIRE SHALL MEET ALL APPLICABLE NATIONAL ELECTRICAL CODE ARTICLES FOR FIRE AND LOW VOLTAGE WIRING. 31) THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS, THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATION TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA. Fire Alarm System Check Off List For Final Inspection Following is a list of items that must be completed before the Fire Department will perform a final inspection. 1 Low Voltage Electrical Final Completion Date: 2 Line Voltage Electrical Final Completion Date: 3 Elevator Final Completion Date: 4 Pressurization a Stairwell Completion Date: b Elevator Completion Date: 5 Sprinkler System (100% Complete) All Valves in normal condition. Completion Date: 6 Interior Building Construction. Completion Date: (i.e. doors, floor covering, ceiling covers, ceiling tiles, windows, etc.) 7 HVAC Completion Date: 8 Suppression Systems Completion Date: 9 Safety and ADA Requirements, Fire Extinguishers Completion Date: 10 Specialty Furniture Completion Date: 11 Monitoring (See Below) 12 Final Fire Alarm Inspection Completion Date: 13 Approved Set of plans and permit on site Completion Date: Phone line (lines) must be installed and active. 14 Fire Alarm Monitoring Completion Date: a Dual Line Communicator Completion Date: b Scan Line Date Line Due In: (If Required by Jurisdiction) c Contract Signed Completion Date: d Scan Line ordered (Alarm Company) Completion Date: e Stu Installed and Tested Completion Date: 2 Elevator Monitoring Completion Date: RIVERTON TERRACE APARTMENTS SEQUENCE OF OPERATIONS MANUAL PULL STATION SMOKE DETECTION ELEVATOR MACHINE RM/SHAFT SMOKE DET. MAIN FLOOR ELEV. LOBBY SMOKE DET. OTHER FLOOR ELEV. LOBBY SMOKE DET. HEAT DETECTION DUCT SMOKE DETECTION WET FLOW SWITCH WET TAMPER SWITCH POST INDICATOR VALVE SYSTEM TROUBLE ACTIVATION OF LOCAL ALARM AT FACP X X X X X X X INDICATION OF ALARM AT LCD ANNUNCIATOR X X X X X X X ACTIVATE ALL AUDIBLE & VISIBLE DEVICES X X X X X X X INITIATE ELEV. RECALL TO MAIN FLOOR X INITIATE ELEV. RECALL TO ALTERNATE FLOOR X X X RELEASE DOOR HOLDERS X X X X X X X X TRANSMIT ALARM SIGNAL TO CENTRAL STATION X X X X X X X TROUBLE/SUPV. INDICATION AT FACP X X X X TROUBLE/SUPV. INDICATION AT LCD ANNUNCIATOR X X X X TRANSMIT TROUBLE/SUPV. SIGNAL TO CENTRAL STATION X X X X A.D.A, REGULATION COMPLIANCE MIMES CONTROLS N8) FIRE ALARM PULL STATION $WLI. BE NOUNTED AT +48' TO TOP. EIRE M.M0 NOICATINO APPLIANCES SHALL BE PLACED 80' ABOVE THE ROBS FLOOR LEVEL WITHIN INE SPACE OR 8' BELow THE CEILING, WHIWEVER IS LOMER TO A.O.A. CIODEJl1ES. WP EOL CKT #16 THIS PAGE SHOULD BE 24" X 36". IF THIS SHEET IS ANY OTHER SIZE, ADJUST THE SCALE ACCORDINGLY S15-1 S15-2 S15-3 S14-1 S15-4 S15-5 S15-6 S14-2 S14-3 • v ■ ■ S13-1 • ■ • • S15-7 S14-4 S14-5 S14-6 S13-2 S13-3 S12-1 NAC #3 NAC #2 v ■ • • ■ ■ S13-4 S12-2 S12-3 • • ■ ■ v ■ S12-4 • ■ S14-7 • ■ S13-5 S13-6 EOL CKT #13 S12-5 S12-6 S12-7 • ■ • • ■ ■ S11-1 S11-2 S11-3 S11-4 S11-5 IEt1 11:11 I ) H EOL — cKT #11 S10-1 S10-2 S9-1 S15-8 S15-9 EOL CKT #15 S14-8 S14-9 , EOL CKT #14 S12-8 S12-9 • • ■ ■ EOL CKT #12 4©0040000000000000000000000000 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 S10-3 S9-2 S9-3 S8-1 S8-2 S8-3 • ■ S7-1 S7-2 S10-4 S10-5 S10-6 S9-4 S9-5 S8-4 S7-3 • ■ S7-4 S10-7 S9-6 • ■ S9 -7 • ■ S8-5 S8-6 EOL CKT #8 S7-5 ■ ■ S10-8 S10-9 EOL CKT #10' S9-8 S9-9 EOL CKT #9 S7-6 S7-7 S7-8 S7-9 S6-1 S6-2 S6-3 S6-4 S6-5 ANN Igo EOL OCT #6 • ■ EOL CKT #7 ----------------- THIRD FLOOR 0 M 0 0 00 00 0000 0 0 0 0 00 0 0 0 00 0 0 0 0 00 0 01 0 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 SECOND FLOOR S5-1 S5-2 S5-3 S5-4 S5-5 NAC #1 • • • ■ S4-1 S4-2 S4-3 S4-4 EOL CKT #5 S4-5 S4-6 OsU ■ ■ S3-1 S3-2 S3-3 S3-4 /"--13-43 )f EOL CKT #3 S2-1 S2-2 S2-3 S2-4 S2-5 ■ ■ S4-7 • ■ S4-8 S4-9 EOL CKT #4 S2-6 S2-7 S2-8 S2-9 EOL CKT #2 S1-1 S1-2 S1-3 S1-4 S1-5 S1-6 EEOL CKT #1 FACP ANN 1 QHI • ■ O©© © ©©© ©_ ©_ © O ©© Q Q©© Q Q Q 0 0 0 000 00 0 0 0 00 0 0 0000 0 0 0 0 00 0 Q Q© Q Q o 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 1 IRI DOOR HOLDER RELAY TELCO x2 120VAC DEDICATED FIRST FLOOR Riverton Terrace Apartments Riser Diagram RISER DIAGRAM FIRE ApND�SECURIrTY LEGAL NOTICE THE PLANS AND SPECIFICATIONS ARE COPYRIGHT MATERIALS AND ARE THE SOLE PROPERTY OF EVERGREEN FIRE AND SECURITY. ANY INFRINGEMENT ON THE COPYRIGHT OR UNAUTHORIZED USE OF THESE PLANS OR SPECIFICATIONS RENDERS THE USER LIABLE TO THE LAWS OF THE UNITED STATES. GENERAL NOTES REVISIONS/NOTES JOB DETAILS SAL CHANGE DATE APPRVD BY FOR SUBMITTAL 09/21/07 JCK AHJ CORRECTIONS/CHANGES 10/05/07 JCK CHECKED BY: JCK CREATION DATE: 09/20/07 DRAWING SCALE: JOB NAME RIVERTON TERRACE APARTMENTS MULTI -SITE UPGRADE PROJECT 14410 41st AVE. SOUTH TUKWILA, WASHINGTON 98168 jSUBMITTED BY EVERGREEN FIRE AND SECURITY 3215 SOUTH 12TH STREET TACOMA, WA. 98405 253-627-3794 SHEET NUMBER FA002 SHEET 2 OF 6 JOB DETAILS SAL DESIGNED BY: DRAWN BY: BFM CHECKED BY: JCK CREATION DATE: 09/20/07 DRAWING SCALE: VARIES JOB NAME RIVERTON TERRACE APARTMENTS MULTI -SITE UPGRADE PROJECT 14410 41st AVE. SOUTH TUKWILA, WASHINGTON 98168 jSUBMITTED BY EVERGREEN FIRE AND SECURITY 3215 SOUTH 12TH STREET TACOMA, WA. 98405 253-627-3794 SHEET NUMBER FA002 SHEET 2 OF 6 MAINTENANCE & STO 107 THIS PAGE SHOULD BE 24" X 36". IF THIS SHEET IS ANY OTHER SIZE, ADJUST THE SCALE ACCORDINGLY GE D ELEVATOR MACHINERY 109 QH SHUNTT TR HEA TO FAC EVA P C 75CD 5-5 EDL COMMU ITY ROOM L 106 L 'S cd OFFICE 1° 106A Riverton Terrace Apartments FIRST FLOOR SCALE: 3/16"=1'-0" / tilts"Afitittibbilitrit LEGAL NOTICE THE PLANS AND SPECIFICATIONS ARE COPYRIGHT MATERIALS AND ARE THE SOLE PROPERTY OF EVERGREEN FIRE AND SECURITY. ANY INFRINGEMENT ON THE COPYRIGHT OR UNAUTHORIZED USE OF THESE PLANS OR SPECIFICATIONS RENDERS THE USER LIABLE TO THE LAWS OF THE UNITED STATES. GENERAL NOTES / REVISIONS/NOTES JOB DETAILS CHANGE DATE APPRVD BY FOR SUBMITTAL 09/21/07 JCK AHJ CORRECTIONS/CHANGES 10/05/07 JCK BFM CHECKED BY: FOG CREATION DATE: 09/20/07 •/ JOB DETAILS DESIGNED BY: SAL DRAWN BY: BFM CHECKED BY: FOG CREATION DATE: 09/20/07 DRAWING SCALE: AS NOTED / JOB NAME RIVERTON TERRACE APARTMENTS MULTI -SITE UPGRADE PROJECT 14410 41st AVE. SOUTH TUKWILA, WASHINGTON 98168 SUBMITTED BY EVERGREEN FIRE AND SECURITY 3215 SOUTH 12TH STREET TACOMA, WA. 98405 253-627-3794 / SHEET NUMBER FA1.0 SHEET 3 OF 6 65® 75CD 6-5 EDL [�.. 62 58 30CD 7-6 15CD 7-9 EOL 211 5 30CD 209 15CD 7-4 3OCD 7-2 530 30CD -r 5 7-1 TO FACP F 7-3 15CD 64 P� 5 TO FACP 9 (t o 6-4 75CD 54 15CD 9-9 EOL 210 208 30D 6099-8 30CD 30CD 56 9-6 30CD 207 TO FACP c 205 THIS PAGE SHOULD BE 24" X 36". IF THIS SHEET IS ANY OTHER SIZE, ADJUST THE SCALE ACCORDINGLY 5D 715 9 7/ 75CD 6-3 206 30CD TO FACP CD ®51 ,9-1 Riverton Terrace Apartments SECOND FLOOR 8-5 3,OCD 43 203 15CD 'O6 41% 37 TO FACP s4 6-2 75CD 202 10-5 30C' 10-6 201 30CD 41 8 H 10-7 30CD 51 6 2 6-1 75CD 30CD 39 10-8 15CD 10- EOL 9 SCALE: 3/16"=1'-0" r FIRE AND SECURITY / LEGAL NOTICE THE PLANS AND SPECIFICATIONS ARE COPYRIGHT MATERIALS AND ARE THE SOLE PROPERTY OF EVERGREEN FIRE AND SECURITY. ANY INFRINGEMENT ON THE COPYRIGHT OR UNAUTHORIZED USE OF THESE PLANS OR SPECIFICATIONS RENDERS THE USER LIABLE TO THE LAWS OF THE UNITED STATES. GENERAL NOTES REVISIONS/NOTES JOB DETAILS CHANGE DATE APPRVD BY FOR SUBMITTAL 09/21/07 JCK AHJ CORRECTIONS/CHANGES 10/05/07 JCK BFM CHECKED BY: JCK 09/20/07 CREATION DATE: DRAWING SCALE: / JOB DETAILS DESIGNED BY: SAL DRAWN BY: BFM CHECKED BY: JCK 09/20/07 CREATION DATE: DRAWING SCALE: AS. NOTED JOB NAME RIVERTON TERRACE APARTMENTS MULTI -SITE UPGRADE PROJECT 14410 41st AVE. SOUTH TUKWILA, WASHINGTON 98168 SUBMITTED BY EVERGREEN FIRE AND SECURITY 3215 SOUTH 12TH STREET TACOMA, WA. 98405 253-627-3794 SHEET NUMBER FA200 SHEET 4 OF 6 THIS PAGE SHOULD BE 24" X 36". IF THIS SHEET IS ANY OTHER SIZE, ADJUST THE SCALE ACCORDINGLY 97 75CD 11-5 EOL t: 15CD 15-9 FOL Riverton Terrace Apartments THIRD FLOOR SCALE: 3/16"=1'-0" RE AND SECURITY / LEGAL NOTICE THE PLANS AND SPECIFICATIONS ARE COPYRIGHT MATERIALS AND ARE THE SOLE PROPERTY OF EVERGREEN FIRE AND SECURITY. ANY INFRINGEMENT ON THE COPYRIGHT OR UNAUTHORIZED USE OF THESE PLANS OR SPECIFICATIONS RENDERS THE USER LIABLE TO THE LAWS OF THE UNITED STATES. GENERAL NOTES /--------REVISIONS/NOTES JOB DETAILS SAL CHANGE DATE APPRVD BY FOR SUBMITTAL 09/21/07 JCK AHJ CORRECTIONS/CHANGES 10/05/07 JCK CHECKED BY: JCK CREATION DATE: 09/20/07 DRAWING SCALE: JOB NAME RIVERTON TERRACE APARTMENTS MULTI -SITE UPGRADE PROJECT 14410 41st AVE. SOUTH TUKWILA, WASHINGTON 98168 / SUBMITTED BY EVERGREEN FIRE AND SECURITY 3215 SOUTH 12TH STREET TACOMA, WA. 98405 253-627-3794 / SHEET NUMBER FA300 SHEET 5 OF JOB DETAILS SAL DESIGNED BY: DRAWN BY: BFM CHECKED BY: JCK CREATION DATE: 09/20/07 DRAWING SCALE: AS NOTED JOB NAME RIVERTON TERRACE APARTMENTS MULTI -SITE UPGRADE PROJECT 14410 41st AVE. SOUTH TUKWILA, WASHINGTON 98168 / SUBMITTED BY EVERGREEN FIRE AND SECURITY 3215 SOUTH 12TH STREET TACOMA, WA. 98405 253-627-3794 / SHEET NUMBER FA300 SHEET 5 OF RIVERTON TERRACE S. LEHMAN 7/12/2007 5820XL 5820XL CTRL Panel Addrsbl SLC Devices Power Expander Sounder Base Notification Appl Circuit cfg. Notification Appl Circuit cfg. Notification Appl Circuit cfg. Notification Appl Circuit cfg. Notification AppI Circuit cfg. #12 Solid 1.086 #12 Solid #12 Solid 1.086 #12 Solid 0.000 #12 Solid 0.000 #12 Solid 4.521 0.000 0.000 0.000' 4 26% 4.23% 0.96% 4.40% 0.00% 0.00% Command Shortcuts Configure Circuits Battery Calculation Worksheet Riverton Terrace NAC #2 NAC Ckts. 9,10,11 & 12 Device Description Quantity of Devices Standby mA Per Device Alarm mA Per Device Tot. Device Standby mA Tot Device Alarm mA 5496 NAC Expander Panel 1 40 160 40 160 0 0 0 0 0 0 0 0 0 0 0 0 0 0 40 160 Auxilliary Devices (list all) 4 -wire duct detector 2 -wire Smoke Detector SIS 2400 0 0 Door Holder 0 0 EOL relay 0 0 UV detector 0 0 Other Auxilliary Device Totals Notification Appliances (list all) NS24MCWFR (30) 18 151 2718 NS24MCWFR (75) 6 228 0 1368 RSS24MCWFR (15) 9 60 0 540 0 N/A 0 N/A 0 Aux relays Other 0 N/A 0 0 N/A 0 N/A N/A 0 0 Notification Appliance Totals 33 4626 Summary Section Standby Hrs. Required 24 Alarm Sounding Minutes 5 Total System Standby mA 40 Total System Alarm mA 4786 Total System Standby AIH 0.96 Total System Alarm AIH 0.40 Min. NH Battery Required 1.36 Derating Factor 1.2 Recommended NH Battery 1.63 BATTERY USED- 2 EA. 7 AIH Battery Calculation Worksheet Riverton Terrace NAC #3 NACCkts.13,14,15&16 Device Battery Calculation Worksheet Riverton Terrace NAC#1 NACCkts.5,6,7&8 Description 5496 NAC Expander Panel Quantity of Devices 1 Standby mA Per Device 40 Alarm mA Per Device 160 Tot Device Standby mA 40 Tot Device Alarm mA 160 0 0 0 0 0 0 Device Description Quantity of Devices Standby mA Per Device Alarm mA Per Device Tot Device Standby mA Tot Device Alarm mA 0 0 0 0 0 0 5496 NACiExpander Panel 40 160 40 160 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 40 160 Auxilliary Devices (list all) 4 -wire duct detector 2 -wire Smoke Detector SIS 2400 Door Holder EOL relay UV detector Other Auxilliary Device Totals 0 0 0 0 40 160 Auxilliary Devices (list all) 4 -wire duct detector 0 0 2 -wire Smoke Detector SIS 2400 0 0 Door Holder 0 0 EOL relay 0 0 UV detector 0 0 Other 0 0 Auxilliary Device Totals 0 0 0 0 0 0 0 Notification Appliances (list all) 0 0 0 0 0 0 0 NS24MCWFR (30) 16 151 0 2416 Notification Appliances (list all) NS24MCWFR (30) NS24MCWFR (75) RSS24MCWFR (15) 12 151 0 1812 7 228 0 1596 7 60 0 420 0 N/A 0 N/A 0 Aux relays Other 0 N/A 0 N/A 0 N/A 0 N/A Notification Appliance Totals 26 0 0 0 3828 NS24MCWFR (75) 0 228 0 0 RSS24MCWFR (15) 8 60 0 480 ASWP2475WFR Aux relays 1 0 N/A 200 0 0 200 N/A 0 Other 0 N/A 0 N/A 0 Notification Appliance Totals 25 0 3096 Summary Section Standby Hrs. Required Summary Section Standby Hrs. Required Alarm Sounding Minutes Total System Standby mA Total System Alarm mA Total System Standby NH Total System Alarm NH Min. NH Battery Required Derating Factor 24 5 40 3988 0.96 0.33 1.29 1.2 Alarm Sounding Minutes Total System Standby mA Total System Alarm mA Total System Standby AIH Recommended NH Battery 1.55 BATTERY USED- 2 EA. 7 AM Total System Alarm NH Min. NH Battery Required Derating factor Recommended NH Battery 24 5 40 3256 0.96 0.27 1.23 1.2 1.48 BATTERY USED- 2 EA. 7 AIH Panel NAC 3 CHANGE DATE APPRVD BY FOR SUBMITTAL 09/21/07 JCK AHJ CORRECTIONS/CHANGES 10/05/07 JCK BFM CHECKED BY: JCK CREATION DATE: 09/20/07 DRAWING SCALE: VARIES Circuit Device Current # of Devices Current EOL Ohms Per Foot X Total Wire Length N-13 NS-24MCWFR(30) 0.151 X 4 = 0.604 550 X 1.086 = 0.950 23.050 EOL RSS -24MC W F R (15) 0.060 X 2 = 0.12 Ohms Per Foot X Total Wire Length Current VDC Voltage X = 0 1.59 170 340 X 0.724 = 0.391 23.609 X = 0 1000 X = 0 X Total Wire Length Current VDC Voltage 1.59 175 350 X 1.086 X 0.604 = 0 1 Total Curre 0.724 Circuit Device Current # of Devices Current Current N-14 NS -24MC W F R (30) 0.151 X 6 = 0.906 EOL Ohms Per Foot X Total Wire Length Current EOL 0.228 RSS-24MC W F R (15) 0.060 X 3 = 0.18 Ohms Per Foot Current X Total Wire Length VDC Current VDC Voltage X = 0 1.59 275 550 X 1.086 = 0.950 23.050 X = 0 1000 X = 0 EOL Ohms Per Foot X Total Wire Length Current X Voltage = 0 500 X 1.086 = 0.863 23.137 Total Curre 1.368 Total Curre 1.086 Circuit Device Current # of Devices Current Circuit Device Current # of Devices Current N-15 NS -24MC W F R (30) 0.151 X 6 = 0.906 RSS-24MCWFR (15) 0.060 X 3 EOL Ohms Per Foot RS -24MC W F R (15) 0.060 X 3 = 0.18 Ohms Per Foot Voltage X Total Wire Length Current X VDC Voltage 1.59 250 500 X 1.086 = 0 1.59 200 400 X 1.086 = 0.691 23.309 X = 0 1000 X = 0 X = 0 Total Curre 1.086 • Total Curre 1.086 Circuit Device Current # of Devices Circuit Device Current # of Devices Current N-16 AS W P -2475W F R 0.200 X 1 = 0.2 RSS -24MCWFR (15) 0.060 X EOL = 0.12 Ohms Per Foot X = 0 Ohms Per Foot VDC X Total Wire Length Current VDC Voltage X = 0 1.59 100 200 X 0.2 = 0.064 23.936 X = 0 1000 X = 0 X = 0 Total Cu . 0.2 FACP Circuit Device Current # of Devices Current Panel -1 NS -24MC W F R (75) 0.228 X 2 0.456 NS-24MCCFR(75) 0.228 X 4 0.912 Ohms Per Foot X Total Wire Length Current VDC EOL Voltage X 0 1.59 200 400 X 1.368 0.870 23.130 X 0 1000 X 0 X 0 X 0 Total Curre 1.368 Circuit Device Current # of Devices Current Panel -2 NS -24MC WF R (30) 0.151 X 6 0.906 RSS-24MCWFR(15) 0.060 X 3 0.18 Ohms Per Foot X Total Wire Length Current VDC X 0 1.59 250 500 X 1.086 0.863 EOL Voltage 23.137 X 0 1000 X 0 X 0 Total Curre 1.086 Circuit Device Current # of Devices Current Panel -3 NS -24MC WF R (30) 0.151 X 3 0.453 RSS-24MCWFR(15) 0.060 X 1 0.06 X 0 Ohms Per Foot X Total Wire Length Current VDC EOL Voltage 1.59 120 240 X 0.513 0.196 23.804 X 0 1000 X 0 X 0 Total Curre 0.513 Circuit Device Panel -4 NS -24MC WF R (30) Current, 0.151 # of Devices Current X 6 0.906 RSS-24MCWFR(15) 0.060 3 0.18 Ohms Per Foot 1.59 X Total Wire Length Current VDC 260 520 1.086 0.898 EOL Voltage 23.102 1000 Total Curre 1.086 Panel NAC 1 CHANGE DATE APPRVD BY FOR SUBMITTAL 09/21/07 JCK AHJ CORRECTIONS/CHANGES 10/05/07 JCK BFM CHECKED BY: JCK CREATION DATE: 09/20/07 DRAWING SCALE: VARIES Circuit Device Current # of Devices Current EOL Ohms Per Foot X Total Wire Length Current VDC Voltage 1.59 275 550 X 1.086 = 0.950 23.050 1000 RSS-24MCWFR (15) 0.060 X 2 = 0.12 Ohms Per Foot X Total Wire Length Current VDC Voltage EOL Ohms Per Foot X Total Wire Length Current VDC Voltage 1.59 175 350 X 1.086 = 0.604 23.396 1000 Circuit Device Current # of Devices Current EOL Ohms Per Foot X Total Wire Length Current NS-24MCCFR(75) 0.228 X 4 = 0.912 Ohms Per Foot 1.368 X Total Wire Length 0.979 Current 1000 VDC Voltage EOL Ohms Per Foot X Total Wire Length Current VDC Voltage 1.59 250 500 X 1.086 = 0.863 23.137 Total Curre 1.368 Circuit Device Current # of Devices Current . RSS-24MCWFR (15) 0.060 X 3 = 0.18 Ohms Per Foot X Total Wire Length Current VDC Voltage X = 0 1.59 250 500 X 1.086 = 0.863 23.137 Total Curre 1.086 Circuit Device Current # of Devices Current RSS -24MCWFR (15) 0.060 X 2 = 0.12 Ohms Per Foot X Total VVire Length Current VDC Voltage Total Curre 0 0.724 Panel NAC 2 Circuit Device Current # of Devices N-9 0.151 6 0.060 3 Total Curre Circuit Device Current # of Devices N-10 NS -241VC WFR (30) 0.151 6 0.060 3 Total Curre Circuit Device Current # of Devices 0.228 2 NS-24MCCFR(75) 0.228 4 Total Curre Circuit Device Current # of Devices N-12 0.151 6 RSS-24MCWFR (15) 0.060 3 Total Curre Current 0.906 0.18 0 0 0 0 1.086 Current 0.906 0.18 0 0 0 0 1.086 Current 0.456 0.912 0 0 0 0 1.368 Current 0.906 0.18 0 0 0 0 1.086 LEGAL NOTICE THE PLANS AND SPECIFICATIONS ARE COPYRIGHT MATERIALS AND ARE THE SOLE PROPERTY OF EVERGREEN FIRE AND SECURITY. ANY INFRINGEMENT ON THE COPYRIGHT OR UNAUTHORIZED USE OF THESE PLANS OR SPECIFICATIONS RENDERS THE USER LIABLE TO THE LAWS OF THE UNITED STATES. GENERAL NOTES / REVISIONS/NOTES BY: CHANGE DATE APPRVD BY FOR SUBMITTAL 09/21/07 JCK AHJ CORRECTIONS/CHANGES 10/05/07 JCK BFM CHECKED BY: JCK CREATION DATE: 09/20/07 DRAWING SCALE: VARIES EOL Ohms Per Foot X Total Wire Length Current VDC Voltage 1.59 275 550 X 1.086 = 0.950 23.050 1000 EOL Ohms Per Foot X Total Wire Length Current VDC Voltage 1.59 175 350 X 1.086 = 0.604 23.396 1000 EOL Ohms Per Foot X Total Wire Length Current VDC Voltage 1.59 225 450 X 1.368 = 0.979 23.021 1000 EOL Ohms Per Foot X Total Wire Length Current VDC Voltage 1.59 250 500 X 1.086 = 0.863 23.137 1000 LEGAL NOTICE THE PLANS AND SPECIFICATIONS ARE COPYRIGHT MATERIALS AND ARE THE SOLE PROPERTY OF EVERGREEN FIRE AND SECURITY. ANY INFRINGEMENT ON THE COPYRIGHT OR UNAUTHORIZED USE OF THESE PLANS OR SPECIFICATIONS RENDERS THE USER LIABLE TO THE LAWS OF THE UNITED STATES. GENERAL NOTES / REVISIONS/NOTES BY: CHANGE DATE APPRVD BY FOR SUBMITTAL 09/21/07 JCK AHJ CORRECTIONS/CHANGES 10/05/07 JCK BFM CHECKED BY: JCK CREATION JOB NAME RIVERTON TERRACE APARTMENTS MULTI -SITE UPGRADE PROJECT 14410 41st AVE. SOUTH TUKWILA, WASHINGTON 98168 SUBMITTED BY EVERGREEN FIRE AND SECURITY 3215 SOUTH 12TH STREET TACOMA, WA. 98405 253-627-3794 SHEET NUMBER FAO 4 SHEET 6 OF 6 BY: SAL DESIGNED DRAWN BY: BFM CHECKED BY: JCK CREATION DATE: 09/20/07 DRAWING SCALE: VARIES JOB NAME RIVERTON TERRACE APARTMENTS MULTI -SITE UPGRADE PROJECT 14410 41st AVE. SOUTH TUKWILA, WASHINGTON 98168 SUBMITTED BY EVERGREEN FIRE AND SECURITY 3215 SOUTH 12TH STREET TACOMA, WA. 98405 253-627-3794 SHEET NUMBER FAO 4 SHEET 6 OF 6 A. . •I SLC D- c SLC Loop Expander LCD Remote Annunc Serial/Parallel Module Power Expander LED Annunciator (4G) LED Annunciator (3G) LED Driver Module Sounder Base Relay Base Duct Hsg w/Relay Relay Module Notification Appl Circuit Notification Appl Circuit cfg. Notification Appl Circuit ct9• Notification Appl Circuit " cf9. Notification Appl Circuit cf9• Notification Appl Circuit cfg. 1.204 #12 Solid 0.822 #12 Solid 0.381' #12 Solid 0.822 #12 Sold 3.75% 3.20% 0.71% 3.33% Command Shortcuts Panel FACP gure Circu Print Page Circuit Device 1 Current # of Devices Panel -1 NS-24MCWFR(75) 10.184 NS-24MCCFR(75) X0.209 X 2 X 4 X X X X X Total Curr Circuit Device 1 Current # of Devices Panel -2 NS-24MCWFR(30) 1 0.107 X 6 RSS-24MCWFR(15) 0.060 X 3 X X X X Total CurrE Circuit Device 1 Current # of Devices Panel -3 NS-24MCWFR(30) 1 0.107 X 3 RSS-24MCWFR(15) 1 0.060 X 1 X X X X Total CurrE Circuit Device 1 Current # of Devices Panel -4 NS-24MCWFR(30) 1 0.107 X 6 RSS-24MCWFR(15) 1 0.060 X 3 X X X X Total CurrE Current 0.368 0.836 0 0 0 0 0 1.204 Current 0.642 0.18 0 0 0 0 0.822 Current 0.321 0.06 0 0 0 0 0.381 Current 0.642 0.18 0 0 0 0 0.822 Panel NAC 1 Circuit Device 1 Current # of Devices N-5 NS-24MCWFR(30) 1 0.107 X I 2 RSS-24MCWFR(15) 1 0.060 X I 2 NS-24MCCFR(75) 0.209 X I 1 X X X Total CurrE Circuit Device 1 Current # of Devices N-6 NS-24MCWFR(75) X0.184 X 1 2 NS-24MCCFR(75) 10.209 X I 4 X X X X Total CurrE Circuit N-7 Device 1 Current NS-24MCWFR(30) 1 0.107 # of Devices X I 6 RSS-24MCWFR(15) 1 0.060 X I 3 X X X X Total CurrE Circuit Device I Current # of Devices N-8 NS-24MCWFR(30) 1 0.107 RSS-24MCWFR(15) 1 0.060 X I 4 X I 2 X X X Current 0.214 0.12 0.209 0 0 0 0.543 Current 0.368 0.836 0 0 0 0 1.204 Current 0.642 0.18 0 0 0 0 0.822 Current 0.428 0.12 0 0 0 X I = Total CurrE 0 0.548 Panel NAC 2 Battery Calculation Worksheet Battery Calculation Worksheet AHJ CORRECTIONS/CHANGES 10/05/07 JCK CHECKED BY: Circuit Device 1 Riverton Terrace NAC Ckts. 9,10,11 & 12 Current N-9 NS-24MCWFR(30) _ L)� NAC#1 NAC Ckts. 5, 6, 7 & 8 = 0.642 L Device Quantity of Devices Standby mA Per Device Alarm mA Per Device Device Quantity of Standby mA _ Alarm mA Tot Device Tot Device Description Devices Per Device Per Device Standby mA Alarm mA 5496 NAC Expander Panel 1 40 160 40 160 X 0 0 0 0 0 160 o 0 = 0 0 0 0 0 Total 0 0 Circuit 0 0 0 0 Current 0 1 0.107 0 0 0 0 0 RSS-24MCWFR(15) 0 0 0 40 160 Auxilliary Devices (list all) 0 0 X= 4 -wire duct detector 40 160 Auxilliary Devices (list alt) X Total Wire Length X Current 0.822 = VDC 4 -wire duct detector 1.59 250 500 0 0 2 -wire Smoke Detector SIS 2400 0 0 EOL relay 0 0 Door Holder 0 0 UV detector 0 0 EOL relay 0 0 Other 0 0 UV detector 0 0 Auxilliary Device Totals 0 0 Other 0 0 0.836 0 0 AuxilliaryDevice Totals 0 Notification Appliances (list all) 0 0 0 Auxilliary Device Totals X NS24MCWFR (30) 18 0 Notification Appliances (list all) 0 1926 EOL Ohms Per Foot NS24MCWFR (30) 12 107 0 1284 NS24MCCFR (75) 5 240 209 0 1045 NS24MCWFR (75) 2 1000 184 0 368 RSS24MCWFR (15) 7 N/A 60 0 420 N/A 0 WA 0 N/A 0 Aux relays 0 N/A 0 N/A 0 Other 0 N/A 0 N/A 0 Notification Appliance Totals 26 Other 0 X 3117 - Summary Section Notification Appliance Totals Standby Hrs. Required • 24 X - EOL Ohms Per Foot X Total Wire Length Summary Section Current 40 1 Voltage Standby Hrs. Required 24 520 X Alarm Sounding Minutes 5 0.680 23.320 1000 I Total System Standby mA 40 0.32 Total System Alarm mA 3277 # of Devices Min. NH Battery Required 11.28 NS-24MCWFR(30) Total System Standby NH 0.96 4 Recommended AIH Battery 1.53 BATTERY USED- 2 EA 7 AIH Total System Alarm NH 0.27 2 = 0.12 Min. NH Battery Required 1.23 X Total System Standby AIH = 0 Derating Factor 1.2 L USED- 2 EA. 7 A/H = 0 Recommended NH Battery 1.48 BATTERY Panel NAC 2 Battery Calculation Worksheet Battery Calculation Worksheet AHJ CORRECTIONS/CHANGES 10/05/07 JCK CHECKED BY: Circuit Device 1 Riverton Terrace NAC #2 NAC Ckts. 9,10,11 & 12 Current N-9 NS-24MCWFR(30) 0.107 X 6 = 0.642 RSS-24MCWFR(15) Device Quantity of Devices Standby mA Per Device Alarm mA Per Device EOL Ohms Per Foot Description X Total Wire Length 1 Current = VDC Voltage 1.59 200 400 X 1.204 0.766 23.234 1000 Standby mA X 0 0 0 160 40 160 o 0 = 0 0 0 0 0 Total CurrE 0.822 Circuit 0 0 0 Current 0 1 0.107 X 0 0 0 0 RSS-24MCWFR(15) 0.060 X 0 40 160 Auxilliary Devices (list all) 0 X= 4 -wire duct detector EOL Ohms Per Foot . X Total Wire Length X Current 0.822 = VDC Voltage 1.59 250 500 0.653 23.347 1000 0 0 EOL relay Total Cum' 0.822 0 0 UV detector _ # of Devices 0 0 0 Other 0.184 X 2 0 0 Auxilliary Device Totals 0 0.209 X 0 0 0.836 0 0 X Notification Appliances (list all) 0 0 0 Auxilliary Device Totals X NS24MCWFR (30) 18 0 Current 0 1926 EOL Ohms Per Foot = X Total Wire Length" 836 VDC Voltage 1.59 120 240 X 0.381 = ------- 0.145 ----- 23.855 1000 540 Device 0 N/A 0 N/A 0 Aux relays 0 N/A 0 N/A 0 Other 0 N/A' 0 N/A 0 Notification Appliance Totals 33 0 0 Aux relays 3670 N/A = 0 0 Other 0 X 0 - Summary Section Notification Appliance Totals Standby Hrs. Required • 24 X - EOL Ohms Per Foot X Total Wire Length Current 40 VDC Voltage 1.59 260 520 X 0.822 = 0.680 23.320 1000 I I I Total System Alarm NH 0.32 Current # of Devices Min. NH Battery Required 11.28 NS-24MCWFR(30) Derating Factor 1.2 4 Recommended AIH Battery 1.53 BATTERY USED- 2 EA 7 AIH 0.060 X 2 = 0.12 X Total System Standby AIH = 0 X Total System Alarm AIH = 0 X Min. NH Battery Required = 0 I X Derating factor = 0 Recommended NH Battery Total CurrE 0.548 Circuit Device Current EOL Ohms Per Foot X Total Wire Length N-14 Current 0.107 VDC Voltage 1.59 150 300 X 0.543 = 0.259 23.741 1000 X = 0 X = 0 X = 0 X = 0 Total CurrE 0.822 Circuit Device Current # of Devices Current N-15 NS-24MCWFR(30) EOL Ohms Per Foot 6 X Total Wire Length 0.642 Current RSS-24MCWFR(15) VDC Voltage 1.59 225 450 X 1.204 = 0.861 23.139 �- 1000 = 0 X = 0 X = 0 X = 0 Total CurrE 0.822 I Circuit Device Current #of Devices Current N-16 ASWP-2475WFR 0.168 EOL Ohms Per Foot ® X Total Wire Length Current VDC Voltage 1.59 250 500 X 0.822 = 0.653 23.347 1000 = 0 X = 0 - = 0 Total CurrE 0.168 EOL Ohms Per Foot X Total Wire Length Current VDC Voltage 1.59 150 300 X 0.548 = 0.261 23.739 1000 Panel NAC 2 Battery Calculation Worksheet Battery Calculation Worksheet AHJ CORRECTIONS/CHANGES 10/05/07 JCK CHECKED BY: Circuit Device - - Riverton Terrace NAC #2 NAC Ckts. 9,10,11 & 12 Current N-9 NS-24MCWFR(30) 0.107 X 6 = 0.642 RSS-24MCWFR(15) Device Quantity of Devices Standby mA Per Device Alarm mA Per Device Tot Device Standby mA Tot Device Alarm mA Description 5496 NAC Expander Panel 1 40 160 40 160 Standby mA Alarm mA X Tot Device 0 0 Per Device Per Device Standby mA X 0 0 0 160 40 160 o 0 = 0 0 0 0 0 Total CurrE 0.822 Circuit 0 0 0 Current 0 0 0.107 X 0 0 0 0 RSS-24MCWFR(15) 0.060 X 0 40 160 Auxilliary Devices (list all) 0 X= 4 -wire duct detector 0 . 0 0 2 -wire Smoke Detector S/S 2400 0 0 40 160 0 0 Door Holder - 0 0 0 EOL relay Total Cum' 0.822 0 0 UV detector _ # of Devices 0 0 0 Other 0.184 X 2 0 0 Auxilliary Device Totals 0 0.209 X 0 0 0.836 0 0 X Notification Appliances (list all) 0 0 0 Auxilliary Device Totals X NS24MCWFR (30) 18 0 107 0 1926 NS24MCCFR (75) 4 = 209 0 836 NS24MCWFR (75) 2 184 0 368 RSS24MCWFR (15) 9 0 60 0 540 Device 0 N/A 0 N/A 0 Aux relays 0 N/A 0 N/A 0 Other 0 N/A' 0 N/A 0 Notification Appliance Totals 33 0 0 Aux relays 3670 N/A = 0 0 Other 0 X 0 - Summary Section Notification Appliance Totals Standby Hrs. Required • 24 X - Alarm Sounding Minutes 5 X Total System Standby mA 40 0 Total System Alarm mA 3830 Total Curr 0.822 Panel Total System Standby AIH 0.96 I I I I Total System Alarm NH 0.32 Current # of Devices Min. NH Battery Required 11.28 NS-24MCWFR(30) Derating Factor 1.2 4 Recommended AIH Battery 1.53 BATTERY USED- 2 EA 7 AIH Panel NAC 2 1 CHANGE DATE APPRVD BY Battery Calculation Worksheet AHJ CORRECTIONS/CHANGES 10/05/07 JCK CHECKED BY: Circuit Device Current 09/20/07 # of Devices VARIES Current N-9 NS-24MCWFR(30) 0.107 X 6 = 0.642 RSS-24MCWFR(15) 0.060 X 3 = 0.18 X = 0 Quantity of Standby mA Alarm mA X Tot Device = 0 Per Device Per Device Standby mA X 5496 NAC Expander Panel = 0 160 40 160 X = 0 0 0 Total CurrE 0.822 Circuit Device Current 0 Current N-10 NS-24MCWFR(30) 0.107 X 0 0 0.642 RSS-24MCWFR(15) 0.060 X 0 0.18 0 X= 0 0 . X X = 0 0 40 160 Auxilliary Devices (list all) X - 0 4 -wire duct detector Total Cum' 0.822 Circuit Device Current _ # of Devices 0 Current N-11 NS-24MCWFR(75) 0.184 X 2 = 0.368 NS-24MCCFR(75) 0.209 X 4 = 0.836 0 0 X = 0 0 0 Auxilliary Device Totals X = 0 0 X = 0 Notification Appliances (list all) X = 0 16 107 0 Total CurrE 1.204 Circuit Device Current - # of Devices NS24MCWFR (75) Current N-12 NS-24MCWFR(30) 0.107 X 6 = 0.642 60 RSS-24MCWFR(15) 0.060 X 3 = 0.18 0 200 Aux relays X N/A = 0 0 Other 0 X 0 - 0 Notification Appliance Totals 25 X - 0 X = 0 Total Curr 0.822 Panel NAC 3 I I I I Circuit Device Current # of Devices Current N-13 NS-24MCWFR(30) 0.107 X 4 = 0.428 RSS-24MCWFR(15) 0.060 X 2 = 0.12 X Total System Standby AIH = 0 X Total System Alarm AIH = 0 X Min. NH Battery Required = 0 I X Derating factor = 0 Recommended NH Battery Total CurrE 0.548 Circuit Device Current # of Devices Current 1 N-14 NS-24MCWFR(30) 0.107 X 6 = 0.642 RSS-24MCWFR(15) 0.060 X 3 = 0.18 X = 0 X = 0 X = 0 X = 0 Total CurrE 0.822 Circuit Device Current # of Devices Current N-15 NS-24MCWFR(30) 0.107 X 6 = 0.642 RSS-24MCWFR(15) 0.060 X 3 = 0.18 X = 0 X = 0 X = 0 X = 0 Total CurrE 0.822 I Circuit Device Current #of Devices Current N-16 ASWP-2475WFR 0.168 X 1 ® 0.168 X X __ = 0 X = 0 X = 0 Total CurrE 0.168 Ohms Per Foot 1.59 X Total Wire Length Current VDC EOL Voltage 275 550 X 0.822 0.719 23.281 1000 Ohms Per Foot 1.59 X Total Wire Length Current VDC EOL Voltage 175 350 X 0.822 0.457 23.543 1000 Ohms Per Foot 1.59 225 X Total Wire Length 450 Current VDC EOL Voltage 1.204 0.861 23.139 1000 Ohms Per Foot 1.59 X Total Wire Length Current VDC EOL Voltage 250 500 X 0.822 0.653 23.347 1000 Ohms Per Foot 1.59 170 X Total Wire Length 340 Current VDC EOL Voltage 0.548 0.296 23.704 1000 EOL Ohms Per Foot 1.59 X Total Wire Length Current VDC Voltage 275 550 X 0.822 0.719 23.281 1000 Ohms Per Foot 1.59 X Total Wire Length 200 400 Current VDC EOL Voltage X 0.822 0.523 23.477 1000 Ohms Per Foot X Total Wire Length Current VDC EOL Voltage 1.59 100 200 X 0.168 0.053 23.947 1000 / IRE AND SEC URITY / LEGAL NOTICE THE PLANS AND SPECIFICATIONS ARE COPYRIGHT MATERIALS AND ARE THE.SOLE PROPERTY OF EVERGREEN FIRE AND SECURITY. ANY INFRINGEMENT ON THE COPYRIGHT OR UNAUTHORIZED USE OF THESE PLANS OR SPECIFICATIONS RENDERS THE USER LIABLE TO THE LAWS OF THE UNITED STATES. GENERAL NOTES / REVISIONS/NOTES JOB DETAILS SAL CHANGE DATE APPRVD BY Battery Calculation Worksheet AHJ CORRECTIONS/CHANGES 10/05/07 JCK CHECKED BY: JCK CREATION DATE: 09/20/07 DRAWING SCALE: VARIES Riverton Terrace 1 NAC #3 NAC Ckts. 13, 14, 15 & 16 Device Quantity of Standby mA Alarm mA Tot Device Tot Device Description Devices Per Device Per Device Standby mA Alarm mA 5496 NAC Expander Panel 1 40 160 40 160 0 0 0 0 0 0 0 0 0 0 0 0 0 0 40 160 Auxilliary Devices (list all) 4 -wire duct detector 0 0 2 -wire Smoke Detector SIS 2400 0 0 Door Holder 0 0 EOL relay 0 0 UV detector 0 0 Other 0 0 Auxilliary Device Totals 0 0 0 Notification Appliances (list all) NS24MCWFR (30) 16 107 0 1712 NS24MCCFR (75) 0 209 0 0 NS24MCWFR (75) 0 184 0 0 RSS24MCWFR (15) 8 60 0 480 ASWP2475WFR 1 200 0 200 Aux relays 0 N/A 0 N/A 0 Other 0 N/A 0 N/A 0 Notification Appliance Totals 25 0 2392 Summary Section Standby Hrs. Required 24 Alarm Sounding Minutes 5 Total System Standby mA 40 Total System Alarm mA 2552 Total System Standby AIH 0.96 Total System Alarm AIH 0.21 Min. NH Battery Required 1.17 Derating factor 1.2 Recommended NH Battery 1.41 BATTERY USED -2 EA 7 AIH Ohms Per Foot 1.59 X Total Wire Length Current VDC EOL Voltage 275 550 X 0.822 0.719 23.281 1000 Ohms Per Foot 1.59 X Total Wire Length Current VDC EOL Voltage 175 350 X 0.822 0.457 23.543 1000 Ohms Per Foot 1.59 225 X Total Wire Length 450 Current VDC EOL Voltage 1.204 0.861 23.139 1000 Ohms Per Foot 1.59 X Total Wire Length Current VDC EOL Voltage 250 500 X 0.822 0.653 23.347 1000 Ohms Per Foot 1.59 170 X Total Wire Length 340 Current VDC EOL Voltage 0.548 0.296 23.704 1000 EOL Ohms Per Foot 1.59 X Total Wire Length Current VDC Voltage 275 550 X 0.822 0.719 23.281 1000 Ohms Per Foot 1.59 X Total Wire Length 200 400 Current VDC EOL Voltage X 0.822 0.523 23.477 1000 Ohms Per Foot X Total Wire Length Current VDC EOL Voltage 1.59 100 200 X 0.168 0.053 23.947 1000 / IRE AND SEC URITY / LEGAL NOTICE THE PLANS AND SPECIFICATIONS ARE COPYRIGHT MATERIALS AND ARE THE.SOLE PROPERTY OF EVERGREEN FIRE AND SECURITY. ANY INFRINGEMENT ON THE COPYRIGHT OR UNAUTHORIZED USE OF THESE PLANS OR SPECIFICATIONS RENDERS THE USER LIABLE TO THE LAWS OF THE UNITED STATES. GENERAL NOTES / REVISIONS/NOTES JOB DETAILS SAL CHANGE DATE APPRVD BY FOR SUBMITTAL 09/21/07 JCK AHJ CORRECTIONS/CHANGES 10/05/07 JCK CHECKED BY: JCK CREATION DATE: 09/20/07 DRAWING SCALE: JOB NAME RIVERTON TERRACE APARTMENTS MULTI -SITE UPGRADE PROJECT 14410 41st AVE. SOUTH TUKWILA, WASHINGTON 98168 SUBMITTED BY EVERGREEN FIRE AND SECURITY 3215 SOUTH 12TH STREET TACOMA, WA. 98405 253-627-3794 j SHEET NUMBER FAO4 SHEET 6 OF 6 JOB DETAILS SAL DESIGNED BY: DRAWN BY: BFM CHECKED BY: JCK CREATION DATE: 09/20/07 DRAWING SCALE: VARIES JOB NAME RIVERTON TERRACE APARTMENTS MULTI -SITE UPGRADE PROJECT 14410 41st AVE. SOUTH TUKWILA, WASHINGTON 98168 SUBMITTED BY EVERGREEN FIRE AND SECURITY 3215 SOUTH 12TH STREET TACOMA, WA. 98405 253-627-3794 j SHEET NUMBER FAO4 SHEET 6 OF 6