HomeMy WebLinkAboutPP - 13123 48TH AVE S - HUSKY INTERNATIONAL TRUCKS - PERMITS AND PLANS13123 48TH AVE S ASSOCIATED PERMITS 08-F-509 08-5-232 Project Name: two IFire & Security Scope Of Work Husky International 13123 48th Avenue S Tukwila, WA 98168 FIRE ALARM INSTALLATION By: ADT Security Services 11824 North Creek Parkway N., Suite 105 Bothell, WA 98011 ADT Representative: Jeff McLaughlin Telephone: 425-402-3351 FILE Quantity Model Description ftJKW1LA FIRE DEPARTbilk.All Please call: 575-4407 and give this job F- J exact address for shut, A.ol or restoration approval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. 1 1 1 1 NOTE: D7412 D263 (By Others) (By Others) Radionics Fire Alarm Control Panel Smoke Detector Waterflow Switch OS&Y Switch 1. Remove existing Radionics 8112 2. Install new Radionics D7412 Fire Alarm Control Panel. 3. Install new Smoke Detector above FACP. 4. Connect to customer owned sprinkler devices. 5. Panel is programmed for monitoring. 1 --- Rise+ code. -10 S< /-..-3-y -s. adders){s 444vKc c -e 5#44-. r h t k lo oA• ot�./,-u o. FA — 1-654x, a 44.. 0141. iCk0 14 Doi ACCEPTED 11 Without Commis Ear As Noted in Red 0 Per The Attached Leber nese plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted stanaaras and ordinances. The responsibility for the adequacy of design rests totally with the designer. lw Additions, deletions or revisions to these drawings atter this date will .void thie acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection b‘ The Tukwila Fire Prevention Bureau. [Date: // -1 �1 - 03 By: -S l r L ar • i two IFire & Security Battery Calculation Worksheet (all currents stated in mA) 11/1412008 PROJECT: HUSKY INTERNATIONAL Device Quantity of Standby mA Alarm mA Total Device Total Device Description Devices _ Per Device Per Device Standby mA Alarm mA System Devices RADIONICS D7412 1 200 500 200 500 0 0 D263 SMOKE DETECTOR 1 0 0 0.1 0.1 Min. NH Battery 4.84 0 0 33 0 0 0 0 0 0 0 Total System Current 0 0 200 500 Smoke Detectors / Auxiliary Devices Standby Hrs. Required 24 N/A 5 0 0 D263 SMOKE DETECTOR 1 0.1 0.1 0.1 0.1 Min. NH Battery 4.84 N/A 1.45 33 0 N/A 0 0 N/A 0 0 0 N/A 0 0 0 N/A 0 0 Device Totals 1 33.1 0.1 Notification Appliances (list all) Standby Hrs. Required 24 N/A 5 N/A 0 Total System Alarm mA 500.1 N/A 4.80 N/A 0 Min. NH Battery 4.84 N/A 1.45 N/A 0 N/A N/A 0 N/A N/A 0 0 N/A N/A 0 0 N/A N/A 0 Notification Appliance Totals 0 N/A 0 Summary Section Standby Hrs. Required 24 Alarm Sounding Minutes 5 Total System Standby mA 233.1 Total System Alarm mA 500.1 Total System Standby NH 4.80 Total System Alarm AIH 0.04 Min. NH Battery 4.84 ADD 30% FOR BATTERY DEPLETION 1.45 Required AIH Battery 6.30 A/H BATTERY PROVIDED FOR SYSTEM 7 1 DO NOT EXCEED TOTAL CURRENT DRAW OF 3000mA MANG a3SIb 3N11 -3N0 0 c_ CD P 111 I ( I r FIRE ALARM SYSTEM - PANEL REPLACEMENT HUSKY INTERNATIONAL 13123 48TH AVENUE SOUTH TUKWILA. WA 98168 / Hydraulics Summary Sheet SECURITY FIRE PROTECTION P.O. BOX 487 SOUTH PRAIRIE, WASHINGTON 98385 360 897-6839 Designer: BARR I E D. HAANEN Calc By: BARR I E 0. HAANEN Date: MAY 22, 2008 Project Information HUSKY TRUCK 13123 - 48TH AVENUE SOUTH TUKWILA, WASHINGTON 98168 Contract No: Building: System ID: Ref. Drawing No: Construction: Occupancy: B-28100 PAINT BOOTH HUSKY TRUCK B-28100 1 OF 1 Authority: TUKWILA FIRE MARSHALL System Information Hydraulics Design Criteria System Type: WET PIPE Density: .40 GPM/Sc t Remote Area: 2 AS Soft Sprinkler Coverage: 54.96 ScFt Design Standard: NFPA NO. 13 - 2007 EDITION Hazard: EXTRA GROUP II Figure: N/A Curve: N/A Sprinklers / Nozzles_ Manufacturer: TYCO Model: TY -FRB Size: 3/4" I.P.T. K—Factor: 8.0 Temp. Rating: 286 Hydraulics Information Demand... Spr Req'd Pres: Spr Req'd Flow: Add'I Flows: Hose at Srce: Total Flow: Total Pres: Static Bev: 45.92 PSI 45.56 GPM 0.00 GPM 500.00 GPM 545.56 GPM 45.92 PSI 8.00 Ft Supply... Water Flow Test Static: 160.00 PSI Residual: 135.00 PSI Qty Flowing: 1500.00 GPM Elevation: 0.00 Ft Date:S/21/08 Time:N/A By: TUKWILA FIRE DEPARTMENT Pump Data Rated: 0.0 PSI! 0.0 GPM Boost Pres: <NA) PSI Discharge Pres: (NA) PSI Discharge Flow: <NA) GPM Combined Static: Residual: Qty Flowing: (NA) PSI (NA) PSI (NA) GPM Available... P) 156.15 PSI! 545.56 GPM F) 45.92 PSI! 3404.86 GPM Margin... Pressure: 110.23 PSI Flow: 2859.30 GPM Sigma Dynamics Corporation 7700 Summary Sheet 1 er oa a0 a0 e 0E E ao E— aa oa OW Eo CO wti O 0 .1 - HUSKY TRUCK (ISd) eid t 1500.00 .880 a 8s xxxz P0-%%% (000W N 0 01 `0 0 8 1 N LA b m Z _ gin sure 110.: 2859.: 1 1tf 11 1 1 0 i RgRg.c-tEssgil)sqsaF-8sse22.317 (ISd) eid t 1500.00 .880 a 8s xxxz P0-%%% (000W N 0 01 `0 0 8 1 N LA SUBMITTAL SERIAL NO:2142HY12 HUSKY TRUCK B-28100 EXTRA HAZARD OCCUPANCY GROUP II .40 GPM DENSITY / ENTIRE PAINT BOOTH ADD 500 GPM FOR INSIDE/OUTSIDE HOSE WET PIPE SYSTEM PAINT BOOTH CALCULATIONS BY: BARRIE D. HAANEN FOR: SECURITY FIRE PROTECTION P.O. BOX 487 SOUTH PRAIRIE, WASHINGTON 98385 360 897-6839 WASHINGTON LICENSE NUMBER SECURFP000BF LOCATION: HUSKY TRUCK 13123 - 48TH AVENUE SOUTH TUKWILA, WASHINGTON 98168 TYCO SPRINKLER MODEL TY -FRB K = 8.0 3/4" I.P.T. 286 DEGREE WET PIPE SYSTEM PAINT BOOTH FLOW TEST RESULTS Water Supply STATIC 160.00 PSI RESIDUAL 135.00 PSI @ 1500.00 GPM CITY PRESSURE AVAILABLE AT 545.6 GPM 156.15 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K -FACTOR 101 23.58 21.98 8.00 102 21.98 21.98 8.00 TOTAL WATER REQUIRED FOR SYSTEM OUTSIDE HOSE STREAMS AT 0 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 7 TO 8 PRESSURE 8.69 7.55 45.56 GPM 500.00 GPM 545.56 GPM 45.92 PSI 0.10 PSI 16.91 FPS 05-22-2008 PAGE 1 SUBMITTAL SERIAL N0:2142HY12 HUSKY TRUCK B-28100 EXTRA HAZARD OCCUPANCY GROUP II .40 GPM DENSITY / ENTIRE PAINT BOOTH ADD 500 GPM FOR INSIDE/OUTSIDE HOSE WET PIPE SYSTEM PAINT BOOTH 05-22-2008 PAGE 2 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 101 102 1.049 L 8.00 C=120 PT 7.55 (102) Q 21.98 F=0 F 0.00 PE 0.00 BN T 8.00 0.1550 PF 1.24 13 101DQ 23.58 1.049 L 3.00 C=120 PT 8.79 (101) Q 45.56 F=E F 2.00 PE 0.00 BN1 T 5.00 0.5969 PF 2.98 12 13 1.049 L 4.33 C=120 PT 11.77 ( 13) Q 45.56 F=T,BV F 6.00 PE 1.88 FR1 T 10.33 0.5969 PF 6.17 11 12 1.049 L 1.00 C=120 PT 19.82 ( 12) Q 45.56 F=E F 2.00 PE 0.00 FM1 T 3.00 0.5969 PF 1.79 10 11 1.049 L 6.00 C=120 PT 21.61 ( 11) Q 45.56 F=E F 2.00 PE -2.60 FM1 T 8.00 0.5969 PF 4.78 9 10 1.049 L 0.33 C=120 PT 23.79 ( 10) Q 45.56 F=E F 2.00 PE -0.14 FM1 T 2.33 0.5969 PF 1.39 8 9 1.049 L 20.00 C=120 PT 25.04 ( 9) Q 45.56 F=E F 2.00 PE -8.67 FM1 T 22.00 0.5969 PF 13.13 7 8 1.049 L 10.00 C=120 PT 29.50 ( 8) Q 45.56 F=T F 5.00 PE 0.00 FM1 T 15.00 0.5969 PF 8.95 6 7 2.635 L 27.00 C=120 PT 38.45 ( 7) Q 45.56 F=2E F 8.60 PE -0.43 FM T 35.60 0.0067 PF 0.24 5 6 3.260 L 14.00 C=120 PT 38.26 ( 6) Q 45.56 F=0/T F 13.00 PE 0.00 FM T 27.00 0.0024 PF 0.06 4 5 4.260 L 10.00 C=120 PT 38.32 ( 5) Q 45.56 F=0 F 0.00 PE 0.00 FM T 10.00 0.0006 PF 0.01 SUBMITTAL SERIAL NO:2142HY12 HUSKY TRUCK B-28100 EXTRA HAZARD OCCUPANCY GROUP II .40 GPM DENSITY / ENTIRE PAINT BOOTH ADD 500 GPM FOR INSIDE/OUTSIDE HOSE WET PIPE SYSTEM PAINT BOOTH 05-22-2008 PAGE 3 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 3 4 6.357 L 40.00 C=120 PT 38.33 ( 4) Q 45.56 F=0 F 0.00 PE 0.00 FM T 40.00 0.0001 PF 0.00 2 3 8.249 L 108.00 C=120 PT 38.33 ( 3) Q 45.56 F=E F 13.00 PE 0.00 FM T 121.00 0.0000 PF 0.00 1 2 8.249 L 17.50 C=120 PT 38.33 ( 2) Q 45.56 F=CV/E F 58.00 PE 7.58 FR T 75.50 0.0000 PF 0.00 0 1 8.450 L 150.00 C=140 PT 45.91 ( 1) Q 45.56 F=T,GV/E F 69.20 PE 0.00 UN T 219.20 0.0000 PF 0.00 PT 45.91 ( 0) w .y: L r ' /E/a� Gann I cowl -to I ti l e,e (Mpg V-eba,i�� e59 .taro 1 v tr%mt. (l r2 10-+1. J iL• t to ID 1>G,47 S brA1 U *1 # iota CC E.PTED Without Comments As Noted In Red Per The Attached Letter !nese plans have been reviewed by The Tukwila Fire :prevention Bureau for conformance with current city '.1ndards. Acceptance is suh ect to errors and nissibns which do not authorize violations of adopted naaras and ordinances. The responsibility for the ,,11equacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after is date will void this. acceptance and wit require a submittal of revised drawings for subsequent approval. •nal acceptance is subject to field test and Inspection by ,'►e Tukwila Fire, Prevention Bureau. Date: By: 07 2c fUKWILA FIRE DEPARTIVIE tv't. Please call: 575.4.407 and give this job and exact address for shut- down or restoration aouroval s p,Aik yes. - NOTICE Weld stamps must be inspected before pipe is hung. po not paint piping prior to hydrostatic test approval. /VET: 3(23 v c" 41,1, I L , ` El% C_ SECURITY SOUTH PRAIRIE, WASHINGTON 98385 FIRE PROTECTION (360) 897-6839 FAX (360) 897-6839 WASHINGTON LICENSE NUMBER SECURFPOOOBF 1 SECURITY FIDE i'RQD'ECTI(INIMPORTANT NOT s Fire Sprinklers Save Livesuse of increased demand s ur inspectors' schedules are booked 3-7 days ahead. Therefore, you will need to call 206-5754407 to schedule your inspections a minimum of 48 hours in advance of the date you want an inspection. s -20-0a