HomeMy WebLinkAboutPP - 14603 35TH AVE S - EXPRESS LINEN SERVICE - PERMITS AND PLANS14603 35TH AVE S ASSOCIATED PERMITS 08-F-513 CEILING OUTSIDE BELL/STROBE FIELD VERIFY I.OcA'I'ION AND I[nun' WI1'II (FIRE DEPARTMENT A/V OR VISUAL ONLY DEVICES DOOR PULL STATION 48" 0 ANN 72" CTL PNL EQUIPMENT ELEVATION DETAIL NOT TO SCALE i F..._.•••• ...+..r...- l E TE Without CoT m Its As Noted In P<d Par The Attached Latter 1i nose plans have been reviewed by The Tul„,Fri Fire Prevention Bureau for conformance with current city standards. Acceptance is Sub's -act to errors and i omissions which do not authorize violations of adopted i standards and ordinances. The rer:pen : bili4y for the adequacy of design rests totally with the designer. i Additions, deletions or rovisionra to these drawings atter this date will void thk acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection b‘ The Tukwila Fire Prevention Bureau. Date: 1/'A l -O8 By: NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. C�ti4tiwl.54c 'Ibh ►^.or+; - r 171veot. Adar'e))es 4o 4h hvhcicti`2 ct4 CQ,.,, -1-.t 544. ge�tt0k code - ; 5 -k i t Aveo l c1 h r -ck ( lo C `c o i+ d vjj c -e o' olcot i c41-4 b rt4 4-tv- -- Tns-ic I I Ave. d.ep}. k'hol 30>‘. IMPORTA O ,:i.CrE Because of increased demand our inspectors' schedules are booked 3-7 days ahead. Therefore, you will need to call 206-575-4407 to schedule your inspections a minimum of 48 hours in advance of the date you want an inspection. kons 24' 11'-10" 16'-10" CAWL SPA 1 ACCESS tI 12'-2" S 120 CFM CO I 0l 30cd EMP. LO_NCH RM. 11 ;:, 30cd A (EXIST. COL ) •(EXIST. 5X12 BEAM ABOVE) EXIST. 5X12 BEAM ABOVE) 41-0" 1 4 120CF A NORK • L_ FIRE MAMA LE (E Ifs 11) Q'ty Symbol Y Descriptions p Manufacturer ....._......�..... part # ��- 1 [FACP FIRE ALARM CONTROL PANEL Silent Knight SIL- 5700 1 Remote Annunciate Silent Knight SIL- 5860R [ ANN 4 C ADDRESSABLE PHOTO SMOKE DETECTC Silent Knight SD505APS 9 H ADDRESSABLE HEAT SENSOR Silent Knight SD505AHS 3 ADDRESSABLE PULL STATION Silent Knight SD500PS I F I 4 ITT -<1 Horn/Strobe Std Candela Red System Sensor SYS-P2P 3 \_i Strobe Std Candela Red System Sensor SYS -SR 1 I ��1/vvP Strobe Std Candela Red Outdoor System Sensor SYS-SRK 1 L10 Outside 10" Bell WHEELOCK WI-IE-MBG1024R 1 WHEELOCK IOB-R Surface Back WHEELOCK VVIH1E-IOBR 13 Addressable Base Silent Knight SIL-SD5056AB EOL End of Line Resistor 4.7k ohms Silent Knight WKWILA FIRE DEPARTME91r Please call: 575.4407 and give this job No. 0 R- F-5/ 3 and exact address for shut. down or restoration approval. Fl FFA 1 IRON. - RK ARFn.-_. w 51'-0" UP - 14_i ELF.. 4 Icco REST ROOM 15cd (EXIST. 5X12 BEAM ABOVE) LAUNDF.' WORI< AREA 120 CFM 30cd ROVIDE RECEPTACLE T CEIL. HEIGHT FOR WINDOW SIGN 8-4" EOL 4.7K Li dM / ' 75cd A SCALE : 1/4"= 1' - 0" /1 17'-0" EOL 4.71( PLA r- 30' u.� w eueiRtuO 1W1 D 0 0) 111 00 iV Imo"" 10 co U O CL d~ 0 DESIGN : DONNIE 206-571-2573