Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 12500 TUKWILA INTERNATIONAL BLVD - HOMELAND SECURITY - PERMITS AND PLANS
12500 TUKWILA INTERNATIONAL BLVD 12-F-224 12-F-030 10-F-173 09-F-141 ASSOCIATED PERMITS 04-F-175 04-F-169 04-F-014 15-5-018 12-5-019 12-5-015 10-5-073 09-S-098 09-S-064 04-5-017 "It I I YS S PER is and plans must be cor Bete m order **PLEASE PRINT** ON view. accepted: .q ! Ell King Co. Assessor's Tax No.C+340 (0 QS(Q Site Address —0 T(.,fe-tQ:Jf0. - 1 aite Number loor: 14.17 Tenant Name - New Tenant? ID - Yes Property Owner's Name: 12) Mailing AddresE ga0) "T-1.4V-LC:lia `t) I c `(i ( bl Cd \Q t,O � gbi L 73 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: i—Ei2:1-01) h3(Y'\ Day Telephone: C Q t-1 59- -C I Company Name: CS'1 t t.b ? 1":12. Care C—e A Ai CC -P I RC. . Mailing Address: t9 ra i •-• `s, '-1 , Rk k c. °1 'j City State Zip E-mail Address: brad < bUf (1 (Yl Cc.—WS, LErC. • C.45'm Fax Number: C Ljo - ato i i Valuation of Project (contractor's bid price): $ % > ' Cl0 < t Scope of Work (please provide detailed information): 't'0to . -'+ 'ti''Gkat PERMIT APFLICATIQN NOTES Value of Construction.— In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. FT alb..w cls i \ \ti BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Nance: (,� Y , t' i'7 Cel Inc , Plan Permit App.doc 5/14710. Date: 0.-/C€11 i 1 Day Telephone: C49S 4 0 '--64PA I !rrm8 FEB 10 2D 2 TUKWiioVQ CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION / ,( t King Co. Assessor's Tax No.: Site Address: ti \ \• ,� V l/( y� ` \f1� Suite Number: Floor: 1 sk Tenant Name: �-6-7 G l ! New Tenant" Yes (No Property Owner's Name: SiJM l Of 001(e4100. Mailing Address: 0 I SI L /Mot • 1UX j j t c (�Jv P Q I City State Zip CONTACT PERSON -if there are questions about the submittal. Name: KARINA VELIZ Company Name: GUARDIAN SECURITY SYSTEMS. INC Mailing Address: 1743 — 1ST AVE S E-mail Address: kveliz@guardiansecurity. com Day Telephone: 206-734-6276 x229 City SEATTLE. WA 98134 State Zip Fax Number: 206-341-9928 Valuation of Project (contractor's bid price): $ 1 Cp n Scope of Work (please provide detailed information):\.„,(W \JO 1 ` i JX k�C((3 - ✓ti CAN\IJL- R.GU (15 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING a WNER OR AUT . 0 Signature: ED AGENT: Print Name: . v Lt, M(7 - Date: 1 ()1 Day Telephone: iJ�l t ' 271-t Ct Plan Permit App.doc 5/14/10 TFD FP Form 8 SITE LOCATION Site Address: CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park iiast "Tukwila, WA 98188 206-575-4407 i.)ate application aeeepted: FIRE PROTECTION SYSTEMS I'ERMI ' APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASI. PRINT** 12500 Tukwila International Blvd Tenant Name: USCIS Property Owner's Name: King Co. Assessor's Tax No,: 7340600602 Suite Number: I loor:A_ New 'Tenant'? ❑ - Yes ❑ - No INTERNATIONAL GATEWAY EAST Mailing Address: 12201 Tukwila Intl Blvd Seattle City CONTACT PERSON -if there are questions about the submittal. Name: Mike Irish Company Name: Reliance Fire Protection Mailing Address: PO Box 428 Preston City E-mail Address: mike@reliancefire.com WA 98168 State Zip I)ay 'Telephone: 206-682-6636 State Zip Fax Number: 206-682-6744 Total number of new/relocated devices or sprinkler heads: 3 Valuation of Project (contractor's bid price): $ 1440 Scope of Work (please provide detailed information): Relocate heads for tenant improvement. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will he reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO 13E TRUE UNDER PENALTY OF PERJURY BY Ti -IE LAWS OF THE STATE OR WASHINGTON, AND 1 AM AUTHORIZED TO APPLY • FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Print Name: Mike Irish Signature: Day 'Telephone: Date: 02-10-15 206-682-6636 Plan Permit App.doc 1/2/13 'FFD PP Form 8 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address:12500 TUKWILA INTERNATIONAL BLD. Suite Number: Floor: 3 Tenant Name: DEPARTMENT OF HOMELAND SECURITY New Tenant? ❑ - Yes IN - No Property Owner's Name: SABEY Mailing Address:12201 TUKWILA INTENATIONAL BLVD. SEATTLE, WA. 98032 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: LUKE KOOYMAN Day Telephone: 425-485-2600 EX. 7630 Company Name: REDHAWK FIRE & SECURITY Mailing Address: 21312 30TH DRIVE SE. BOTHELL, WA. 98021 E-mail Address: WA_PERMITS@REDHAWKUS.COM City State Zip Fax Number: 425-486-2611 Contractor's City of Tukwila Business License number: BUS 0993181 Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ 4080 Scope of Work (please provide detailed information): ADDING 3 SMOKE DETECTORS AND 2 SPEAKER/STOBES TO NEW OFFICE SPACES. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNyR Signature: Print Name: (UKE KOOYMAN ZED AGENT: Plan Permit App.doc Date: 02/20/2015 Day Telephone: 425-486-2600 EX 7630 8/22/14 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 12500 TUKWILA INT'L BLVD 4 Site Address: Suite Number: Floor: DHS SEA CAP P2 4th FL TI Tenant Name: New Tenant? ❑ - Yes E:1- No N/A Property Owner's Name: Mailing Address: N/A City State Zip CONTACT PERSON -if there are questions about the submittal. Name: LUKE KOOYMAN Company Name: REDHAWK FIRE & SECURITY Day Telephone: 425-486-2600 EX 7630 Mailing Address?1312 30TH DR SE STE 103 BOTHELL WA 98021 luke.kooyman@redhawkus.com City State Zip E-mail Address: Fax Number: 425-486-2611 Contractor's City of Tukwila Business License number: BUS -0993181 Total number of new/relocated devices or sprinkler heads: 6 Valuation of Project (contractor's bid price): $ $2347.59 Scope of Work (please provide detailed information): Expansion of existing addressable fire alarm system into renovated tenant space. ONE DEVICE JOINT VENTURE WITH REDHAWK F&S ( DESIGN) AND HOLMES ELECTRIC (INSTALLATION) PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 05/02/2016 Print Name: LUKE KOOYMAN Day Telephone: 425-486-2600 Plan Permit App.doc 8/22/14 TFD FP Form 8 w FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Dept. Of Homeland Security 12500 Tukwila Intl. BI. Permit No.: 09-S-098 Date: June 18, 2009 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1 "-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ` of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 30 or more heads require hydrostatic test and system isolation if necessary. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2007 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Dept. Of Homeland Security 12500 Tukwila International BI Permit No.: 10-S-073 Date: May 12, 2010 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2' inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 30 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2007 Edition. . • • LEGENO`s LAYOUT's DEVICE' Aux Power CaIc's Speaker CaIc FACP Calc SLC Calc NAC;Cireuit Load, Vottage Drop &°Battery Load Calculation: APS -9 Output Type »> Description: Standby: Alarm: Circuit Identifiers: Output #1 NAC Sync N9-1 Output #2 NAC Sync N9-2 Output #3 NAC Sync N9-3 Output #4 NAC Sync N9-4 Output #5 Aux Power X -X Total Qty Level 4 FCPS24-S6 Part#: SP2C2415 Ceiling Speaker w/ Strobe set at 15cd 0.0000 0.0550 10 3 11 24 SP2C2430 Ceiling Speaker w/ Strobe set at 30cd 0.0000 0.0790 1 1 1 3 SP2C2475 Ceiling Speaker w/ Strobe set at 75cd 0.0000 0.1400 1 2 1 4 SP2C2495 Ceiling Speaker w/ Strobe set at 95cd 0.0000 0.1730 1 1 0 SC2415W Ceiling Strobe set at 15cd 0.0000 0.0550 1 1 SC2430W . Ceiling Strobe set at 30cd 0.0000 0.0790 0 SC2475W Ceiling Strobe set at 75cd 0.0000 0.1400 0 SC2495W Ceiling Strobe set at 95cd 0.0000 0.1730 2 2 0 SPSCW Ceiling Speaker w/ Strobe set at 15cd 0.0000 0.0710 0 SPSCW Ceiling Speaker wl Strobe set at 30cd 0.0000 0.0960 2 2 SPSCW Ceiling Speaker w/ Strobe set at 75cd 0.0000 0.1530 0 SPSCW Ceiling Speaker w/ Strobe set at 95cd 0.0000 0.1760 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 # Devices per Circuit Total Standby Circuit Calculated Amps (3): Total Alarm Circuit Calculated Amps (1): Wire Gauge Used (awg): Circuit Length (ft): Estimated Voltage Drop (dc): Estimated EOL Voltage (dc): Calculated Voltage Drop %: 12 12 13 0 0 37 0.000 0.000 0.000 0.000 0.0000 0.769 1.290 0.824 0.000 0.0000 14AWG 14AWG 14AWG Select 14AWG Total Amps Required 2.883 400 400 400 0 0 1.60 2.68 1.71 0.00 0.00 22.40 21.32 22.29 24.00 24.00 6.7% 11.2% 7.1% 0.0% 0.0% 1) Current Draw Measurement based on: UL1971, 16-33V, FWR Input, High db & Temporal Patten 2) Outdoor/WP Devices have the same Measured Current Draw as the Indoor Devices and may not listed separately above. 3) When the APS is configured for "Doors", Output #4 shutsdown on loss of AC Power. Therefore no "Standby" Current Draw is shown BATTERY LOAD CALC for APS -9: Total Standby Current: Total Alarrn Current: Spare Capacity Required per NAC Circuit: Total Amp Hours Required (AH): Total Amp Minutes Required (AH): Minimum Battery Size Needed (AH): Spare Battery Capacity Required: Actual Battery Size Required (AH): Total AH Rated Batteries Supplied: = MAXIMUM CHARGER Hours Standby: 24 0.0910 2.2 Minutes Alarm: 15 3.0280 0.8 20% 2.9 Backup Generator? No Voice Evacuation? Yes 20% Military? No 2.9 CAPACITY IS: 18AH 1 5.0 FCPS Calc of 12-044010 Engineering Fire 2012.xlsm 1 of 1 NAC Circuit Load & Voltage Drop Calculation Storage P311 Parking level 3 APS -1 Circuit Number Ckt1 Ckt2 Ckt3 Ckt4 Candella Amps 11 12 13 14 Notifier Speaker Strobes WP Horn Strobe Notifier Strobes WP Strobe SP2W2415 SP2W2430 SP2W2475 SP2W24110 P12241575K S1224MC S1224MC S1224MC S1224MC S241575K 0.080 0.130 0.550 0.038 0.065 0.090 0.118 0.043 0.056, 0.079 0.14(} 0.173 0.05` 0.079 0.140::" 0.173 Notifier Speaker Strobes Ceiling SP2C2415 SP2C2430 SP2C2475 SP2C2495 Notifier Strobes SC2415W Ceiling SC2430W SC2475W SC2495W 30 95 1 5 2 1 Misc WP Bell MDL sync mod 0.030 0.017 # Devices 12 Circuit Amps 1.260 Circuit Length (ft)(14awg) 392 10 11 0 0.972 0.920 0.000 427 256 0 Circuit Length (ft)(12awg) 0 EOL Voltage (14awg) 21.40 EOL Voltage (12awg) 24.00 0 0 0 21.82 22.76 24.00 24.00 24.00 24.00 NAC Circuit Load & Voltage Drop Calculation Parking Level 1 APS -2 Candella Amps Circuit Number Ckt 1 Ckt2 Ckt 3 Ckt 4 21 22 23 24 Notifier Speaker Strobes WP Horn Strobe SP2 W2415 SP2W2430 SP2W2475 SP2W24110 P12241575K 15 - 0.050 30 0.080 0.102 0.130 f .5' 110 4 4 1 4 4 Notifier Strobes WP Strobe S1224MC S1224MC S1224MC S1224MC S241575K 15 0.038 75 15-75 0.090 0.18 0.043 2 Notifier Speaker Strobes SP2C2415 Ceiling SP2C2430 SP2C2475 SP2C2495 30 75 95 0.0551 0.079 6.140? 0.173 1 1 Notifier Strobes SC2415W Ceiling SC2430W SC2475W SC2495W 1 0.0501 30 0.079 75 0.140 95 0.173 Misc WP Bell MDL sync mod 0.030' 0.017 # Devices Circuit Amps Circuit Length (ft)(14awg) Circuit Length (ft)(12awg) EOL Voltage (14awg) EOL Voltage (12awg) 6 8 8 6 0.677 0.813 0.813 0.677 276 224 272 317 0 0 0 0 23.02 23.04 22.84 22.87 24.00 24.00 24.00 24.00 � � cx)5 21 t q NAC Circuit Load & Voltage Drop Calculation Fir1 Elect rm110 APS -3 Candella Amps Circuit Number Ckt 1 Ckt 2 Ckt 3 Ckt 4 31 32 33 34 Notifier Speaker Strobes SP2W2415 SP2W2430 SP2W2475 SP2W24110 WP Horn Strobe P12241575K 1j5 30 0.080 Notifier Strobes WP Strobe 51224MC 51224MC S1224MC S1224MC S241575K 110 15 75 Notifier Speaker Strobes SP2C2415 Ceiling SP2C2430 SP2C2475 SP2C2495 15-75 15 .' 30 Notifier Strobes SC2415W Ceiling SC2430W SC2475W SC2495W 95 15 30 95 0.130 2 0.5.50 0.038) 0.O 1I 0.090 0.118 0.043 0.079 1 0.173 0.055 0.079 0.140' 0.173 2 9 1 Misc WP Bell MDL sync mod 0.017 12 12 17 0 Circuit Amps 1.127 1.008 Circuit Length (ft)(14awg) 515 560 Circuit Length (ft)(12awg) 0 0 EOL Voltage (14awg) 20.95 21.03 EOL Voltage (12awg) 24.00 24.00 1.151 0.000 500 0 0 20.98 24.00 24.00 24.00 NAC Circuit Load & Voltage Drop Calculation Fir 2 Elect rm 210 APS -4 Candella Amps Circuit Number Ckt 1 Ckt 2 41 42 Ckt 3 43 Ckt 4 44 Notifier Speaker Strobes SP2W2415 SP2W2430 SP2W2475 SP2W24110 WP Horn Strobe P12241575K 30 110 '75 0 Notifier Strobes WP Strobe S1224MC 51224MC S1224MC 51224MC 5241575K 15 75 0.080 0.130 .555 : 0.038 0.090 15-75 0.043 Notifier Speaker Strobes SP2C2415 Ceiling SP2C2430 SP2C2475 SP2C2495 Notifier Strobes SC2415W Ceiling SC2430W SC2475W SC2495W 30 75 ,.4. 95 15 30 75 95 8 0.079 7 a40 • 0.173 :055 5 2 0.079 0.140:' 0.173 Misc WP Bell MDL sync mod 0.t50 0.017 # Devices 16 16 12 0 Circuit Amps 1.048 1.085 Circuit Length (ft)(14awg) 299 500 Circuit Length (ft)(12awg) 0 0 EOL Voltage (14awg) 22.35 21.15 EOL Voltage (12awg) 24.00 24.00 0.830 0.000 477 0 0 21.92 24.00 24.00 24.00 NAC Circuit Load & Voltage Drop Calculation Fir 3 Elect rm 310 APS -5 Candella Amps Circuit Number Ckt1 Ckt 2 Ckt 3 Ckt 4 51 52 53 54 Notifier Speaker Strobes WP Horn Strobe SP2W2415 SP2W2430 SP2W2475 SP2W24110 P12241575K 15„".0.050''? 30 0.080 75 0.102 110 0.130 '15.75 . x 0.550 Notifier Strobes WP Strobe 51224MC 51224MC 51224MC 51224MC 5241575K 15 30 75 110" 15-75 0.038 0.065 0.090 0.043 Notifier Speaker Strobes Ceiling SP2C2415 SP2C2430 SP2C2475 SP2C2495 16 30 6 95 0.055 0.079 0.173 2 6 6 Notifier Strobes Ceiling SC2415W SC2430W SC2475W SC2495W 45 30 75" 95 0.055 0.079 0.-14 0.173 2'. 6 5 Misc WP Bell MDL sync mod 0.066 0.017 # Devices Circuit Amps Circuit Length (ft)(14awg) Circuit Length (ft)(12awg) EOL Voltage (14awg) EOL Voltage (12awg) 10 5 16 17 1.306 0.865 1.279 1.164 528 288 459 550 0 0 0 0 20.38 22.69 20.91 20.64 24.00 24.00 24.00 24.00 NAC Circuit Load & Voltage Drop Calculation Fir 1 Elect rm 110 APS -6 Notifier Speaker Strobes WP Horn Strobe Circuit Number Ckt 1 Ckt 2 61 62 Candella Amps SP2W2415 15 0.050- SP2W2430 30 0.080 SP2W2475 75 ,1.62' SP2W24110 110 0.130 P12241575K X16 :.: ;: '0.5507 Ckt 3 63 Ckt 4 64 Notifier Strobes WP Strobe 51224MC 51224MC 51224MC 51224MC 5241575K Notifier Speaker Strobes Ceiling SP2C2415 SP2C2430 SP2C2475 SP2C2495 Notifier Strobes Ceiling SC2415W SC2430W SC2475W SC2495W 15 0.038 0 .. 0.66a 75 0.090 115 15-75 0.043 15 ", F 0.055 3 :"'_ 30 0.079 3 5 0.14 4 ° s 95 0.173 15 0.055 2� 30 0.079 75 -5.140' 95 0.173 6> 2 Misc WP Bel MDL sync mo Bell 0.030 d 0.017 # Devices 12 Circuit Amps 1.072 Circuit Length (ft)(14awg) 300 Circuit Length (ft)(12awg) 0 EOL Voltage (14awg) 22.31 EOL Voltage (12awg) 24.00 13 0 0 1.079 0.000 0.000 250 0 0 0 22.58 24.00 24.00 24.00 24.00 24.00 r 1 0 NAC Circuit Load & Voltage Drop Calculation Fir 2 Elect rm 210 APS -7 Notifier Speaker Strobes WP Horn Strobe SP2W2415 SP2W2430 SP2W2475 SP2W24110 P12241575K Notifier Strobes WP Strobe S1224MC S1224MC S1224MC S1224MC S241575K Circuit Number Ckt 1 Amps 71 30 0.080 110 0.130 0.55 . . 15 0.038 40 rr.06 75 0.090 Candella 15-75 Ckt 2 Ckt 3 Ckt 4 72 73 74 0.043 Notifier Speaker Strobes Ceiling SP2C2415 SP2C2430 SP2C2475 SP2C2495 30 Notifier Strobes Ceiling SC2415W SC2430W SC2475W SC2495W 95 15. 30 95 7 0.079 0.173 0.079 0140 0.173 Misc WP Bell MDL sync mod 0.017 # Devices Circuit Amps Circuit Length (ft)(14awg) 300 Circuit Length (ft)(12awg) 0 EOL Voltage (14awg) 22.32 EOL Voltage (12awg) 24.00 11 10 0 0 1.063 0.753 0.000 0.000 250 0 0 0 23.01 24.00 24.00 24.00 24.00 24.00 NAC Circuit Load & Voltage Drop Calculation Fir 3 Elect rm 310 APS -8 Candella Amps Circuit Number Ckt 1 Ckt 2 81 82 Ckt 3 Ckt 4 83 84 Notifier Speaker Strobes WP Horn Strobe Notifier Strobes WP Strobe SP2W2415 SP2W2430 SP2W2475 SP2W24110 P12241575K S1224MC S1224MC S1224MC S1224MC S241575K 15 30 75 110 15-75 0.050 m 0.080 0.130 15 0.038 75 0.090 018 0.043 0.079 3 Notifier Speaker Strobes Ceiling SP2C2415 SP2C2430 SP2C2475 SP2C2495 Notifier Strobes Ceiling SC2415W SC2430W SC2475W SC2495W Misc WP Bell MDL sync mod 15-75 15 30 5; 95 15 30 0.079 75_ 0.14`' 95 0.173 , 0.173 0.030 0.017 # Devices 13 Circuit Amps 0.872 0.000 0 0 0 0.000 0.000 Circuit Length (ft)(14awg) 500 200 Circuit Length (ft)(12awg) 0 0 EOL Voltage (14awg) 21.71 24.00 EOL Voltage (12awg) 24.00 24.00 0 0 24.00 24.00 24.00 24.00 r NAC Circuit Load & Voltage Drop Calculation Fir 4 Elect rm 410 APS -9 Candella Amps Circuit Number Ckt 1 Ckt 2 Ckt 3 Ckt 4 91 92 93 94 Notifier Speaker Strobes SP2W2415' SP2W2430 SP2W2475 SP2W24110 WP Horn Strobe P12241575K 15 0.050 30 0.080 75 0.102 110 0.130 15-75 "' 0.550 Notifier Strobes S1224MC S1224MC S1224MC S1224MC WP Strobe S241575K 15 0.038 30 0.088 75 0.090 '110 0.118 15-75 0.043 Notifier Speaker Strobes SP2C2415 Ceiling SP2C2430 SP2C2475 SP2C2495 15 0.055 30 0.079 75 0.140 95 0.173 10 1 3 1 1 1 1 1 Notifier Strobes SC2415W Ceiling SC2430W SC2475W SC2495W 15 0.055 300.079 75-- 0.140 95 0.173 2 2 Misc WP Bell MDL sync mod 0.030 0.017 # Devices Circuit Amps Circuit Length (ft)(14awg) Circuit Length (ft)(12awg) EOL Voltage (14awg) EOL Voltage (12awg) 12 3 8 0 0.769 0.401 0.903 0.000 300 200 0 0 0 0 22.79 23.58 24.00 24.00 24.00 24.00 24.00 24.00 . c INS APS -1 Pkg level 3 Item Qty Part # Battery Back up Calculation Description 1 1 FCPS-24S6 2 4 SP2W2475 3 12 SP2W24110 4 9 SP2C2415 5 1 SP2C2430 6 4 SC2415 7 1 SP2W24110 auxiliary power supply speaker strobe 75 cd speaker strobe 110 cd speakerstrobe ceiling 15 cd speakerstrobe ceiling 30 cd strobe, ceiling 15 cd Sync Strobe 110cd w Speaker Total Total Standby Alarm Standby Alarm 0.032000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.032000 0.102000 0.130000 0.055000 0.079000 0.055000 0.191000 0.032000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.032000 0.032000 0.408000 1.560000 0.495000 0.079000 0.220000 0.191000 2.985000 Standby Current Total Hours = 0.032000 X 24 = 0.768000 (Hours) Alarm Current Total Minutes = 2.985000 X .083 = 0.247755 (5 Mins) Total = 1.015755 30% Battery Depletion = 0.304727 Total AH Rated Batteries Needed = 1.320482 Total AH Rated Batteries Supplied 5 INS APS -2 Pkg level 1 Item Qty Part # Battery Back up Calculation Description 1 1 FCPS-24S6 2 3 SP2W2475 3 16 SP2W24110 4 4 SP2C2415 5 4 51224MC auxiliary power supply speaker strobe 75 cd speaker strobe 110 cd speakerstrobe ceiling 15 cd strobe, 30 cd Standby Current Total Hours = Alarm Current Total Minutes = Total 30% Battery Depletion Total AH Rated Batteries Needed Total AH Rated Batteries Supplied Total Total Standby Alarm Standby Alarm 0.032000 0.032000 0.032000 0.032000 0.000000 0.102000 0.000000 0.306000 0.000000 0.130000 0.000000 2.080000 0.000000 0.055000 0.000000 0.220000 0.000000 0.068000 0.000000 0.272000 0.032000 2.910000 0.032000 2.910000 X 24 (Hours) X .083 (5 Mins) 0.768000 0.241530 1.009530 0.302859 1.312389 t 1 • INS APS -3 Floor 1 Electric Rm 110 Item Qty Part # Battery Back up Calculation Description 1 1 FCPS-24S6 2 3 SP2W2430 3 4 SP2C2475 4 12 SP2C2415 5 12 SP2C2430 6 5 SC2415 7 1 SP2C2495 8 2 SP2W24110 auxiliary power supply speaker strobe 30 cd speaker strobe, ceiling, 75 cd speakerstrobe ceiling 15 cd speaker strobe, ceiling, 30 cd strobe, ceiling 15 cd Ceiling Sync Strobe 95cd w Speaker Sync Strobe 110cd w Speaker Standby Current Total Hours = Alarm Current Total Minutes = Total 30% Battery Depletion Total AH Rated Batteries Needed Total AH Rated Batteries Supplied Total Total Standby Alarm Standby Alarm 0.032000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.032000 0.080000 0.140000 0.055000 0.079000 0.055000 0.173000 0.191000 0.032000 X 24 (Hours) 3.270000 X .083 (5 Mins) 0.032000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.032000 0.032000 0.240000 0.560000 0.660000 0.948000 0.275000 0.173000 0.382000 3.270000 0.768000 0.271410 1.039410 0.311823 1.351233 5 INS APS -4 Floor 2 Electric Rm 210 Item Qty Part # Battery Back up Calculation Description 1 3 4 5 6 1 3 25 12 3 FCPS-24S6 SP2C2475 SP2C2415 SP2C2430 SC2415 auxiliary power supply speaker strobe, ceiling, 75 cd speakerstrobe ceiling 15 cd speaker strobe, ceiling, 30 cd strobe, ceiling 15 cd Standby Current Total Hours = Alarm Current Total Minutes = Total 30% Battery Depletion Total AH Rated Batteries Needed Total AH Rated Batteries Supplied Total Total Standby Alarm Standby Alarm 0.032000 0.000000 0.000000 0.000000 0.000000 0.032000 0.140000 0.055000 0.079000 0.055000 0.032000 X 24 (Hours) 2.940000 X .083 (5 Mins) 0.032000 0.000000 0.000000 0.000000 0.000000 0.032000 0.032000 0.420000 1.375000 0.948000 0.165000 2.940000 0.768000 0.244020 1.012020 0.303606 1.315626 5 .. . INS APS -5 Floor 3 Electric Rm 310 Item Qty Part # Battery Back up Calculation Description 1 3 4 5 6 7 1 4 14 14 5 11 FCPS-24S6 SP2C2475 SP2C2415 SP2C2430 SC2415 SC2495W auxiliary power supply speaker strobe, ceiling, 75 cd speakerstrobe ceiling 15 cd speaker strobe, ceiling, 30 cd strobe, ceiling 15 cd Ceiling Sync Strobe 95cd Standby Current Total Hours = Alarm Current Total Minutes = Total 30% Battery Depletion Total AH Rated Batteries Needed Total AH Rated Batteries Supplied Total Total Standby Alarm Standby Alarm 0.032000 0.000000 0.000000 0.000000 0.000000 0.000000 0.032000 0.140000 0.055000 0.079000 0.055000 0.173000 0.032000 X 24 (Hours) 4.646000 X .083 (5 Mins) 0.032000 0.000000 0.000000 0.000000 0.000000 0.000000 0.032000 0.032000 0.560000 0.770000 1.106000 0.275000 1.903000 4.646000 0.768000 0.385618 1.153618 0.346085 1.499703 5 INS APS -6 Floor 1 Electric Rm 310 Item Qty Part # Battery Back up Calculation Description 1 1 FCPS-24S6 3 8 SP2C2475 4 9 SP2C2415 5 4 SP2C2430 6 4 SC2415 auxiliary power supply speaker strobe, ceiling, 75 cd speakerstrobe ceiling 15 cd speaker strobe, ceiling, 30 cd strobe, ceiling 15 cd Standby Current Total Hours = Alarm Current Total Minutes = Total 30% Battery Depletion Total AH Rated Batteries Needed Total AH Rated Batteries Supplied Total Total Standby Alarm Standby Alarm 0.032000 0.000000 0.000000 0.000000 0.000000 0.032000 2.183000 0.032000 0.140000 0.055000 0.079000 0.055000 X 24 (Hours) X .083 (5 Mins) 0.032000 0.000000 0.000000 0.000000 0.000000 0.032000 0.032000 1.120000 0.495000 0.316000 0.220000 2.183000 0.768000 0.181189 0.949189 0.284757 1.233946 5 1 • • , INS APS -7 Floor 2 Electric Rm 310 Item Qty Part # Battery Back up Calculation Description 1 1 FCPS-24S6 3 5 SP2C2475 4 13 SP2C2415 6 1 SC2415 7 2 SP2C2495 auxiliary power supply speaker strobe, ceiling, 75 cd speakerstrobe ceiling 15 cd strobe, ceiling 15 cd Ceiling Sync Strobe 95cd w Speaker Standby Current Total Hours = Alarm Current Total Minutes = Total 30% Battery Depletion Total AH Rated Batteries Needed Total AH Rated Batteries Supplied Total Total Standby Alarm Standby Alarm 0.032000 0.000000 0.000000 0.000000 0.000000 0.032000 1.848000 0.032000 0.140000 0.055000 0.055000 0.173000 X 24 (Hours) X .083 (5 Mins) 0.032000 0.000000 0.000000 0.000000 0.000000 0.032000 0.032000 0.700000 0.715000 0.055000 0.346000 1.848000 0.768000 0.153384 0.921384 0.276415 1.197799 5 INS APS -8 Floor 3 Electric Rm 310 Item Qty Part # Battery Back up Calculation Description 1 1 FCPS-24S6 3 1 SP2C2475 4 8 SP2C2415 5 3 SP2C2430 6 1 SC2415 auxiliary power supply speaker strobe, ceiling, 75 cd speakerstrobe ceiling 15 cd speaker strobe, ceiling, 30 cd strobe, ceiling 15 cd Standby Current Total Hours = Alarm Current Total Minutes = Total 30% Battery Depletion Total AH Rated Batteries Needed Total AH Rated Batteries Supplied Total Total Standby Alarm Standby Alarm 0.032000 0.000000 0.000000 0.000000 0.000000 0.032000 0.140000 0.055000 0.079000 0.055000 0.032000 X 24 (Hours) 0.904000 X .083 (5 Mins) 0.032000 0.000000 0.000000 0.000000 0.000000 0.032000 0.032000 0.140000 0.440000 0.237000 0.055000 0.904000 0.768000 0.075032 0.843032 0.252910 1.095942 5 • . P INS APS -9 Floor 4 Electric Rm 310 Item Qty Part # Battery Back up Calculation Description Total Total Standby Alarm Standby Alarm 1 2 3 4 5 6 1 2 14 2 4 1 FCPS-24S6 SP2C2475 SP2C2415 SP2C2430 SC2495W SP2C2495 auxiliary power supply speaker strobe, ceiling, 75 cd speakerstrobe ceiling 15 cd speaker strobe, ceiling, 30 cd Ceiling Sync Strobe 95cd Ceiling Sync Strobe 95cd w Speaker Standby Current Total Hours = Alarm Current Total Minutes = Total 30% Battery Depletion Total AH Rated Batteries Needed Total AH Rated Batteries Supplied 0.032000 0.000000 0.000000 0.000000 0.000000 0.000000 0.032000 0.140000 0.055000 0.079000 0.173000 0.173000 0.032000 X 24 (Hours) 2.105000 X .083 (5 Mins) 0.032000 0.000000 0.000000 0.000000 0.000000 0.000000 0.032000 0.032000 0.280000 0.770000 0.158000 0.692000 0.173000 2.105000 0.768000 0.174715 0.942715 0.282815 1.225530 5 0 Page 1 OF 52 HYDRAULIC CALCULATIONS MCKINSTRY COMPANY Date 11/19/03 Job: DHS -STP Job_ _ DEPARTMENT OF HOMELAND SECURITY - STANDPIPE CALCULATIONS Authority having Jurisdiction_ _ NFPA System type_ _ Wet Hose 750.0 gpm Inside Hose Water Supply _ 166.50 psi Static, 138.00 psi Residual @ 1550.0 gpm Demand_ _ _ _ 159.06 psi @ 750.0 gpm @ B.O.R. 159.06 psi @ 750.0 gpm @ Supply 159.06 psi available @ 750.0 gpm Demand is at supply curve. FLOW TEST EL= 93' ROOF HOSE VA EL= 183' 100 PSI REQUIRED AT ROOF - 109.39 PSI AVAILIBLE LEVEL P3 SHEET# 8 LEVEL P1 SHEET# 20 LEVEL 1 SHEET# 30 LEVEL 4 SHEET# 42 DLC -- 3 2003 Page 2 MCKINSTRY COMPANY Description of Fitting abbreviations Code Description T Tee VE Victaulic ninety degree elbow B11 Backflow: Ames 2000ss/3000ss Silver Bullet BV Butterfly valve GV Gate valve UE Underground ASCA ninety degree elbow UEE Underground ASCA forty five degree elbow UT1 Underground ASCA tee: flow in run, flow out bullhead only Description of Other abbreviations Code Description CM Cross Main PT Total pressure PE Pressure loss due to elevation changes PF Pressure loss due to friction ".5 Raised to the power of .5 (Square Root) A Actual pipe length F Fitting equivalent pipe length T Total pipe length Page 3 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPARTMENT OF HOMELAND SECURITY - STANDPIPE CALCULATIONS Raw data previous to any calculations No. Code Diam Length Beg End Nd Kfacl Kfac2 Press Elev Hose HW Vel Fit 199 CM1 4.328 4.0 0 0 109.39 0.00 500.0 120 32 1VE,1T,1GV 200 CM1 6.357 13.0 0 0 0.00 11.00 0.0 120 32 201 CM1 6.357 13.0 0 0 0.00 13.00 0.0 120 32 202 CM1 6.357 13.0 0 0 0.00 13.00 0.0 120 32 203 CM1 6.357 15.0 0 0 0.00 15.00 0.0 120 32 204 CM1 6.357 202.0 0 0 0.00 0.00 0.0 120 32 2T,2VE,1BV 205 CM1 8.249 54.0 0 0 0.00 15.50 250.0 120 32 206 CM1 8.249 10.0 0 0 0.00 0.00 0.0 120 32 2VE,1B11 207 CM1 8.249 110.0 0 0 0.00 0.00 0.0 120 32 4VE,2T,1BV 208 CM1 8.270 60.0 0 0 0.00 0.00 0.0 140 32 lUT1 295 G 10.280 60.0 298 296 0.00 0.00 0.0 140 32 lUT1 296 G 12.340 1090.0 296 297 1 CM1 0.00 0.00 0.0 140 32 2UT1,7UEE 297 G 10.280 365.0 297 298 N 0.00 0.00 0.0 140 32 lUT1 298 G 10.280 1160.0 298 299 N 0.00 0.00 0.0 140 32 lUE,2UEE 299 G 12.340 300.0 299 300 N 0.00 0.00 0.0 140 32 lUT1,1UE 300 G 12.340 1540.0 300 301 N 0.00 0.00 0.0 140 32 4UT1 301 G 12.340 130.0 301 297 N 0.00 0.00 0.0 140 32 lUT1,1UE 302 BU 12.340 0.0 300 0 0.00 22.50 0.0 140 32 Pipe Flow No (gpm) Cross main 1 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPARTMENT OF HOMELAND SECURITY - STANDPIPE CALCULATIONS Dia Fitting Length Fr Loss Press Hyd Vel (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) 500.0 gpm = Hose 199 500.0 4.33 200 500.0 201 500.0 202 500.0 203 500.0 204 500.0 A F 1VE 1T T 1GV A F 6.36 T A F 6.36 T A F 6.36 T A F 6.36 T A F 6.36 2T 2VE T 1BV A F T A F 8.25 2VE 1B11 T A F 8.25 4VE 2T T 1BV A F 8.27 lUT1 T 250.0 gpm = Hose 205 750.0 8.25 206 750.0 207 750.0 208 750.0 4.0 41.0 45.0 13.0 0.0 13.0 13.0 0.0 13.0 13.0 0.0 13.0 15.0 0.0 15.0 202.0 113.2 315.2 54.0 0.0 54.0 10.0 28.9 38.9 110.0 149.0 259.0 60.0 24.0 84.0 0.05047 0.00776 0.00776 0.00776 0.00776 0.00776 0.00462 0.00462 0.00462 0.00343 PT PE PF PT PE PF PT PE PF PT PE PF PT PE PF PT PE PF PT PE PF PT PE PF PT PE PF PT PE PF PT 109.39 199 0.00 2.27 111.66 200 4.76 0.10 116.52 201 5.63 0.10 122.25 202 5.63 0.10 127.98 203 6.50 0.12 134.59 204 0.00 2.45 137.04 205 6.71 0.25 144.00 206 0.00 3.43 147.43 207 0.00 1.20 148.63 208 0.00 0.29 148.92 296 K -factor for Cross main 1 = 750.0/(148.92)A.5 = 61.46 10.90 5.05 5.05 5.05 5.05 5.05 4.50 4.50 1B11 = 3.25# 4.50 4.48 Page 4 Notes C = 120 (EL= 11.00 ft) (EL= 13.00 ft) (EL= 13.00 ft) (EL= 15.00 ft) (EL= 15.50 ft) ** C = 140 ** Bulk Jct Page 5 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPARTMENT OF HOMELAND SECURITY - STANDPIPE CALCULATIONS Grid Node Detail Discharge Pressure Outlet Elevation Node (gpm) (psi) K -Value Source (ft) Comments _ =__== _ _ =- 296 750.0 148.92 K=61.46 CM 1 0.00 Split 297 - 149.00 0.00 298 - 148.97 0.00 299 - 149.27 0.00 300 (750.0) 149.31 Feed Jct 0.00 301 - 149.03 0.00 Page 6 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPARTMENT OF HOMELAND SECURITY - STANDPIPE CALCULATIONS Grid Pipe Detail Actual Total Elev Fric Fric Press Press Pipe Diam Len Len Head Flow Loss Loss Vel Nodes a Beg End No. (inch) (Ft) (Ft) (Ft) (Gpm)(Psi/Ft)(Psi)(Fps) Beg End (Psi) (Psi) _ a a =____ 295 10.28 60.0 90.0 0.00 -497.6 0.0006 0.05 1.9 298 296 148.97 148.92 Fit= 30.0 1UT1 296 12.34 1090.0 1227.0 0.00 252.4 0.0001 0.08 0.7 296 297 148.92 149.00 Fit= 137.0 2UT1 7UEE 297 10.28 365.0 395.0 0.00 -169.1 0.0001 0.03 0.7 297 298 149.00 148.97 Fit= 30.0 lUT] 298 10.28 1160.0 1191.0 0.00 328.5 0.0003 0.31 1.3 298 299 148.97 149.27 Fit= 31.0 lUE 2UEE 299 12.34 300.0 358.0 0.00 328.5 0.0001 0.04 0.9 299 300 149.27 149.31 Fit= 58.0 lUT] lUE 300 12.34 1540.0 1688.0 0.00 -421.5 0.0002 0.28 1.1 300 301 149.31. 149.03 Fit= 148.0 4UT1 301 12.34 130.0 188.0 0.00 -421.5 0.0002 0.03 1.1 301 297 149.03 149.00 Fit= 58.0 lUT1 lUE Page 7 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations, DEPARTMENT OF HOMELAND SECURITY - STANDPIPE CALCULATIONS Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Bulk C = 140 ____ A 0.0 PT 149.31 300 Grid Jct 750.0=61.38(149.31)A.5 F 0.0 PE 9.74 (EL= 22.50 ft) 302 750.0 12.34 T 0.0 0.00000 PF 0.00 2.01 PT 159.05 303 Demand is at supply curve. 1 HYDRAULIC CALCULATIONS MCKINSTRY COMPANY Job_ _ DEPT OF HOMELAND SECURITY Occupancy Density Area of Application Coverage per Sprinkler System type_ _ Dry Hose 250.0 gpm Inside PARKING LEVEL P3 ORDINARY HAZARD 0.15 gpm/sq.ft. 1950 square feet 130 S.F. MAX Hose Page 8 Date 10/31/03 Job: DHS -P3 Water Supply _ 166.50 psi Static, 138.00 psi Residual @ 1550.0 gpm Sprinklers - - K=5.6 Demand _ _ _ _ 132.35 psi @ 566.7 gpm @ B.O.R. 132.35 psi @ 566.7 gpm @ Supply 162.07 psi available @ 566.7 gpm Demand is below curve by 29.72 psi Page 9 MCKINSTRY COMPANY Description of Fitting abbreviations Code Description T Tee E Ninety degree elbow VT Victaulic tee VE Victaulic ninety degree elbow Bit Backflow: Ames 2000ss/3000ss Silver Bullet BV Butterfly valve DPV Dry pipe valve UE Underground ASCA ninety degree elbow UEE Underground ASCA forty five degree elbow UT1 Underground ASCA tee: flow in run, flow out bullhead only Description of Other abbreviations Code Description BL Branch Line CM Cross Main PT Total pressure PE Pressure loss due to elevation changes PF Pressure loss due to friction A.5 Raised to the power of .5 (Square Root) A Actual pipe length F Fitting equivalent pipe length T Total pipe length MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY PARKING LEVEL P3 Raw data previous to any calculations No. Code Diam Length Beg End Nd Kfacl 1 BL1 1.416 10.4 0 0 5.6 2 BL1 1.416 10.4 0 0 5.6 3 BL1 1.416 10.4 0 0 5.6 4 BL1 1.416 10.4 0 0 5.6 5 BL1 1.416 10.4 0 0 5.6 6 BL1 1.650 31.0 0 0 7 BL2 1.416 10.4 0 0 5.6 8 BL2 1.416 10.4 0 0 5.6 9 BL2 1.416 10.4 0 0 5.6 10 BL2 1.416 10.4 0 0 5.6 11 BL2 1.650 1.0 0 0 12 BL3 1.416 12.0 0 0 5.6 13 BL3 1.416 12.5 0 0 5.6 14 BL3 1.416 12.5 0 0 5.6 15 BL3 1.416 15.0 0 0 5.6 16 BL3 2.115 16.0 0 0 BL2 17 BL3 2.115 30.0 0 0 5.6 18 CM1 2.731 10.0 0 0 BL1 19 CM1 2.731 174.0 0 0 BL3 20 CM1 3.356 21.0 0 0 21 CM1 3.356 9.0 0 0 180 CM1 3.356 28.0 0 0 181 CM1 3.356 1.0 0 0 182 CM1 3.356 2.0 0 0 187 CM2 8.249 2.0 0 0 CM1 188 CM2 8.249 2.0 0 0 189 CM2 8.249 2.0 0 0 206 CM2 8.249 10.0 0 0 207 CM2 8.249 110.0 0 0 208 CM2 8.270 60.0 0 0 295 G 10.280 60.0 298 296 296 G 12.340 1090.0 296 297 1 CM2. Page 10 Kfac2 Press Elev Hose HW Vel Fit 11.97 0.00 11.97 0.00 11.97 0.00 11.97 0.00 11.97 0.00 0.00 0.00 11.97 0.00 11.97 0.00 11.97 0.00 11.97 0.00 0.00 0.00 10.33 0.00 11.21 0.00 11.21 0.00 11.21 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -13.50 0.00 0.00 0.00 0.00 . 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 .0.00 0.0 100 32 0.0 100 32 0.0 100 32 0.0 100 32 0.0 100 32 0.0 100 32 2E,1T 0.0 100 32 0.0 100 32 0.0 100 32 0.0 100 32 0.0 100 32 1T 0.0 100 32 0.0 100 32 0.0 100 32 0.0 100 32 lE 0.0 100 32 3E 0.0 100 32 1T 0.0 100 32 0.0 100 32 1VT 0.0 100 32 1VT 0.0 100 32 1VE 0.0 100 32 2VE 0.0 100 32 1DPV 0.0 120 32 1T,1BV 0.0 120 32 0.0 120 32 0.0 120 32 0.0 120 32 2VE,1B11 0.0 120 32 4VE,2T,1BV 0.00 0.00 250.0 140 32 lUT1 0.00 0.00 0.0 140 32 lUT1 0.00 0.00 0.0 140 32 2UT1,7UEE Page 11 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY PARKING LEVEL P3 Raw data previous to Any calculations No. Code Diam Length Beg End Nd Kfacl Kfac2 Press Elev Hose HW Vel Fit 297 G 10.280 365.0 297 298 N 0.00 0.00 0.0 140 32 lUT1 298 G 10.280 1160.0 298 299 N 0.00 0.00 0.0 140 32 1UE,2UEE 299 G 12.340 300.0 299 300 N 0.00 0.00 0.0 140 32 1UT1,1UE 300 G 12.340 1540.0 300 301 N 0.00 0.00 0.0 140 32 4UT1 301 G 12.340 130.0 301 297 N 0.00 0.00 0.0 140 32 lUT1,1UE 302 BU 12.340 0.0 300 0 0.00 22.50 0.0 140 32 Page 12 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY PARKING LEVEL P3 Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Branchline No. 1 C = 100 = A 10.4 PT 11.97 1 End head 19.4=5.60(11.97)A.5 F 0.0 PE 0.00 1 19.4 1.42 T 10.4 0.03989 PF 0.41 3.95 A 10.4 PT 12.38 2 19.7=5.60(12.38)A.5 F 0.0 PE 0.00 2 39.1 1.42 T 10.4 0.14609 PF 1.52 7.96 A 10.4 PT 13.90 3 20.9=5.60(13.90)A.5 F 0.0 PE 0.00 3 60.0 1.42 T 10.4 0.32252 PF 3.35 12.22 A 10.4 PT 17.26 4 23.3=5.60(17.26)1%5 F 0.0 PE 0.00 4 83.2 1.42 T 10.4 0.59150 PF 6.15 16.96 A 10.4 PT 23.41 5 27.1=5.60(23.41) .5 F 0.0 PE 0.00 _ 5 110.3 1.42 T 10.4 0.99630 PF 10.36 22.48 A 31.0 PT 33.77 6 F 12.9 PE 0.00 6 110.3 1.65 2E 1T T 43.9 0.47307 PF 20.75 16.55 PT 54.52 18 Cross main Jct K -factor for branchline no. 1 = 110.3/(54.52)'.5 = 14.94 Page 13 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY PARKING LEVEL P3 Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Branchline No. 2 C = 100 A 10.4 PT 11.97 7 End head 19.4=5.60(11.97)A.5 F 0.0 PE 0.00 7 19.4 1.42 T 10.4 0.03989 PF 0.41 3.95 A 10.4 PT 12.38 8 19.7=5.60(12.38)A.5 F 0.0 PE 0.00 8 39.1 1.42 T 10.4 0.14609 PF 1.52 7.96 A 10.4 PT 13.90 9 20.9=5.60(13.90)A.5 F 0.0 PE 0.00 9 60.0 1.42 T 10.4 0.32252 PF 3.35 12.22 A 10.4 PT 17.26 10 23.3=5.60(17.26)A.5 F 0.0 PE 0.00 10 83.2 1.42 T 10.4 0.59150 PF 6.15 16.96 A 1.0 PT 23.41 11 F 6.4 PE 0.00 11 83.2 1.65 1T T 7.4 0.28086 PF 2.09 12.49 PT 25.50 16 Cross main Jct K -factor for branchline no. 2 = 83.2/(25.50)".5 = 16.48 Page 14 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY PARKING LEVEL P3 Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Branchline No. 3 (Beginning pressure increased due to Hyd Ref Pt 13) C = 100 ___= A 12.0 PT 10.78 12 End head 18.4=5.60(10.78)A.5 F 0.0 PE 0.00 12 18.4 1.42 T 12.0 0.03622 PF 0.43 3.75 A 12.5 PT 11.22 13 18.8=5.60(11.22)A.5 F 0.0 PE 0.00 13 37.2 1.42 T 12.5 0.13298 PF 1.66 7.57 A 12.5 PT 12.88 14 20.1=5.60(12.88)A.5 F 0.0 PE 0.00 14 57.3 1.42 T 12.5 0.29596 PF 3.70 11.66 A 15.0 PT 16.58 15 22.8=5.60(16.58)A.5 F 2.4 PE 0.00 15 80.1 1.42 1E T 17.4 0.55033 PF 9.59 16.31 A 16.0 PT 26.17 16 BL2 84.3=16.48(26.17)A.5 F 12.0 PE 0.00 16 164.3 2.12 3E T 28.0 0.29512 PF 8.25 15.01 A 30.0 PT 34.43 17 32.9=5.60(34.43)".5 F 8.0 PE 0.00 17 197.2 2.12 1T T 38.0 0.41346 PF 15.70 18.01 PT 50.13 19 Cross main Jct K -factor for branchline no. 3 = 197.2/(50.13)x'.5 = 27.85 Page 15 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY PARKING LEVEL P3 Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Cross main 1 C = 100 A 10.0 PT 54.52 18 BL1 110.3=14.94(54.52)A.5 F 0.0 PE 0.00 18 110.3 2.73 T 10.0 0.04065 PF 0.41 6.04 A 174.0 PT 54.93 19 BL3 206.4=27.85(54.93)A.5 F 14.0 PE 0.00 19 316.7 2.73 1VT T 188.0 0.28609 PF 53.78 17.35 A 21.0 PT 108.71 20 F 14.4 PE 0.00 20 316.7 3.36 1VT T 35.4 0.10487 PF 3.71 11.49 A 9.0 PT 112.42 21 F 5.5 PE 0.00 21 316.7 3.36 1VE T 14.5 0.10487 PF 1.52 11.49 A 28.0 PT 113.94 180 F 11.1 PE -5.85 (EL= -13.50 ft) 180 316.7 3.36 2VE T 39.1 0.10487 PF 4.10 11.49 A 1.0 PT 112.19 181 F 11.1 PE 0.00 181 316.7 3.36 1DPV T 12.1 0.10487 PF 1.26 11.49 A 2.0 PT 113.45 182 ** C = 120 ** F 38.7 PE 0.00 182 316.7 3.36 1T 1BV T 40.7 0.07484 PF 3.05 11.49 PT 116.50 187 Cross main Jct K -factor for Cross main 1 = 316.7/(116.50)".5 = 29.34 4 - Page 16 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY PARKING LEVEL P3 Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Cross main 2 C = 120 A 2.0 PT 116.50 187 CM 1 316.7=29.34(116.50)A.5 F 0.0 PE 0.00 187 316.7 8.25 T 2.0 0.00094 PF 0.00 1.90 A 2.0 PT 116.50 188 F 0.0 PE 0.00 188 316.7 8.25 T 2.0 0.00094 PF 0.00 1.90 A 2.0 PT 116.50 189 F 0.0 PE 0.00 189 316.7 8.25 T 2.0 0.00094 PF 0.00 1.90 A 10.0 PT 116.51 206 F 28.9 PE 0.00 206 316.7 8.25 2VE 1B11 T 38.9 0.00094 PF 5.45 1.90 1B11 = 5.42# A 110.0 PT 121.96 207 F 149.0 PE 0.00 207 316.7 8.25 4VE 2T T 259.0 0.00094 PF 0.24 1.90 1BV A 60.0 PT 122.20 208 ** C = 140 ** 250.0 gpm = Hose F 24.0 PE 0.00 208 566.7 8.27 lUT1 T 84.0 0.00204 PF 0.17 3.38 PT 122.37 296 Bulk Jct K -factor for Cross main 2 = 566.7/(122.37)A.5 = 51.23 4 - Page 17 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY PARKING LEVEL P3 Grid Node Detail Discharge Pressure Outlet Elevation Node (gpm) (psi) K -Value Source (ft) Comments 296 566.7 297 - 298 299 - 300 (566.7) Pipe Diam No. (inch) 122.37 122.42 122.40 122.59 122.61 K=51.23 Feed Jct CM 2 0.00 Split 0.00 0.00 0.00 0.00 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY PARKING LEVEL P3 Actual Len (Ft) Grid Pipe Detail Total Len (Ft) 295 10.28 60.0 Fit= 30.0 296 12.34 1090.0 Fit= 137.0 297 10.28 365.0 Fit= 30.0 298 10.28 1160.0 Fit= 31.0 299 12.34 300.0 Fit= 58.0 300 12.34 1540.0 Fit= 148.0 301 12.34 130.0 Fit= 58.0 Elev Fric Fric Head Flow Loss Loss Vel Nodes (Ft) (Gpm)(Psi/Ft)(Psi)(Fps) Beg End Page 18 Press @ Beg (Psi) Press @ End (Psi) 90.0 0.00 1UT1 1227.0 0.00 2UT1 7UEE 395.0 0.00 lUT1 1191.0 0.00 lUE 2UEE 358.0 0.00 1UT1 lUE 1688.0 0.00 4UT1 188.0 0.00 lUT1 1UE - 376.0 0.0003 0.03 1.5 298 296 122.40 122.37 190.7 - 127.8 248.2 248.2 -318.5 -318.5 0.0000 0.0000 0.0002 0.0001 0.0001 0.0001 0.05 0.02 0.18 0.02 0.17 0.02 0.5 296 297 122.37 0.5 297 298 122.42 1.0 298 299 122.40 0.7 299 300 122.59 0.9 300 301 122.61 0.9 301 297 122.44 122.42 122.40 122.59 122.61 122.44 122.42 Page 19 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY PARKING LEVEL P3 Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Bulk C = 140 ___= A 0.0 PT 122.61 300 Grid Jct 566.7=51.18(122.61)A.5 F 0.0 PE 9.74 (EL= 22.50 ft) 302 566.7 12.34 T 0.0 0.00000 PF 0.00 1.52 PT 132.35 303 Available flow at 132.35 psi is 1709.2 gpm which is 1142.5 gpm from curve. Supply pressure available with 566.7 gpm flowing is 162.07 psi, thus system requirement is 29.72 psi below supply curve. (18.3%) HYDRAULIC CALCULATIONS MCKINSTRY COMPANY Job_ DEPT OF HOMELAND SECURITY Occupancy Density Area of Application Coverage per Sprinkler System type_ _ Dry Hose 250.0 gpm Inside PARKING LEVEL P1 ORDINARY HAZARD 0.15 gpm/sq.ft. 1950 square feet 130 S.F. MAX Hose Water Supply _ 166.50 psi Static, 138.00 Sprinklers - - K=5.6 Page 23. Date 10/31/03 Job: DHS -P1 psi Residual @ 1550.0 gpm Demand_ _ _ _ 133.29 psi @ 589.8 gpm @ B.O.R. 133.29 psi @ 589.8 gpm @ Supply 161.73 psi available @ 589.8 gpm Demand is below curve by 28.44 psi Page 22 MCKINSTRY COMPANY Description of Fitting abbreviations Code Description T Tee VT Victaulic tee VE Victaulic ninety degree elbow B11 Backflow: Ames 2000ss/3000ss Silver Bullet BV Butterfly valve DPV Dry pipe valve UE Underground ASCA ninety degree elbow UEE Underground ASCA forty five degree elbow UT1 Underground ASCA tee: flow in run, flow out bullhead only Description of Other abbreviations Code Description BL Branch Line CM Cross Main PT Total pressure PE Pressure loss due to elevation changes PF Pressure loss due to friction ".5 Raised to the power of .5 (Square Root) A Actual pipe length F Fitting equivalent pipe length T Total pipe length Page 23 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY PARKING LEVEL P1 Raw data previous to any calculations No. Code Diam Length Beg End Nd Kfacl Kfac2 Press Elev Hose HW Vel Fit 60 BL1 1.416 12.0 0 0 5.6 10.33 0.00 0.0 100 32 61 BL1 1.416 12.5 0 0 5.6 10.33 0.00 0.0 100 32 62 BL1 1.416 12.5 0 0 5.6 10.33 0.00 0.0 100 32 63 BL1 1.416 13.0 0 0 5.6 10.33 0.00 0.0 100 32 64 BL1 1.416 12.5 0 0 5.6 10.33 0.00 0.0 100 32 65 BL1 1.650 17.5 0 0 10.33 0.00 0.0 100 32 1T 66 PC1 0.000 0.0 0 0 BL1 1/5 0.00 0.00 0.0 100 32 67 CM1 2.731 10.0 0 0 BL1 0.00 0.00 0.0 100 32 68 CM1 2.731 10.0 0 0 BL1 0.00 0.00 0.0 100 32 69 CM1 2.731 10.0 0 0 BL1 0.00 0.00 0.0 100 32 70 CM1 2.731 161.0 0 0 PC1 0.00 0.00 0.0 100 32 1VE 71 CM1 3.356 16.0 0 0 0.00 0.00 0.0 100 32 1VT 72 CM1 3.356 18.0 0 0 0.00 0.00 0.0 100 32 1VE,1DPV 186 CM1 3.356 1.0 0 0 0.00 7.50 0.0 120 32 1T,1BV 189 CM2 8.249 2.0 0 0 CM1 0.00 0.00 0.0 120 32 206 CM2 8.249 10.0 0 0 0.00 0.00 0.0 120 32 2VE,1E11 207 CM2 8.249 110.0 0 0 0.00 0.00 0.0 120 32 4VE,2T,1BV 208 CM2 8.270 60.0 0 0 0.00 0.00 250.0 140 32 lUT1 295 G 10.280 60.0 298 296 0.00 0.00 0.0 140 32 lUT1 296 G 12.340 1090.0 296 297 1 CM2 0.00 0.00 0.0 140 32 2UT1,7UEE •297 G 10.280 365.0 297 298 N 0.00 0.00 0.0 140 32 lUT1 298 G 10.280 1160.0 298 299 N 0.00 0.00 0.0 140 32 lUE,2UEE 299 G 12.340 300.0 299 300 N 0.00 0.00 0.0 140 32 lUT1,1UE 300 G 12.340 1540.0 300 301 N 0.00 0.00 0.0 140 32 4UT1 301 G 12.340 130.0 301 297 N 0.00 0.00 0.0 140 32 lUT1,1UE 302 BU 12.340 0.0 300 0 0.00 22.50 0.0 140 32 Page 24, MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY PARKING LEVEL P1 Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Branchline No. 1 C = 100 A 12.0 PT 10.33 60 End head 18.0=5.60(10.33)A.5 F 0.0 PE 0.00 60 18.0 1.42 T 12.0 0 03481 PF 0.42 3.67 A 12.5 PT 10.75 61 18.4=5.60(10.75)".5 F 0.0 PE 0.00 61 36.4 1.42 T 12.5 0.12781 PF 1.60 7.41 A 12.5 PT 12.35 62 19.7=5.60(12.35)A.5 F 0.0 PE 0.00 62 56.0 1.42 T 12.5 0.28450 PF 3.56 11.42 A 13.0 PT 15.90 63 22.3=5.60(15.90)A.5 F 0.0 PE 0.00 63 78.4 1.42 T 13.0 0.52915 PF 6.88 15.97 A 12.5 PT 22.78 64 26.7=5.60(22.78)".5 F 0.0 PE 0.00 64 105.1 1.42 T 12.5 0.91069 PF 11.38 21.41 A 17.5 PT 34.16 65 F 6.4 PE 0.00 65 105.1 1.65 1T T 23.9 0.43242 PF 10.35 15.77 PT 44.51 67 Cross main Jct K -factor for branchline no. 1 = 105.1/(44.51)A.5 = 15.75 at Hyd Ref Pts 67 68 69 70 Page 25 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY PARKING LEVEL P1 Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Cross main 1 C = 100 ____ A 10.0 PT 44.51 67 BL1 105.1=15.75(44.51)A.5 F 0.0 PE 0.00 67 105.1 2.73 T 10.0 0.03717 PF 0.37 5.76 A 10.0 PT 44.88 68 BL1 105.5=15.75(44.88)A.5 F 0.0 PE 0.00 68 210.6 2.73 T 10.0 0.13452 PF 1.35 11.54 A 10.0 PT 46.23 69 BL1 107.1=15.75(46.23)".5 F 0.0 PE 0.00 69 317.8 2.73 T 10.0 0.28781 PF 2.88 17.40 A 161.0 PT 49.11 70 1/5*BL1 22.1=3.15(49.11)A.5 F 4.7 PE 0.00 70 339.8 2.73 1VE T 165.7 0.32589 PF 53.99 18.61 A 16.0 PT 103.10 71 F 14.4 PE 0.00 71 339.8 3.36 1VT T 30.4 0.11946 PF 3.63 12.33 A 18.0 PT 106.72 72 F 16.6 PE 0.00 72 339.8 3.36 1VE 1DPV T 34.6 0.11946 PF 4.13 12.33 A 1.0 PT 110.85 186 ** C = 120 ** F 38.7 PE 3.25 (EL= 7.50 ft) 186 339.8 3.36 1T 1BV T 39.7 0.08526 PF 3.38 12.33 PT 117.49 189 Cross main Jct K -factor for Cross main 1 = 339 6/(117.49)'.5 = 31.35 Page 26 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY PARKING LEVEL P1 Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Cross main 2 C = 120 A 2.0 PT 117.49 189 CM 1 339.8=31.35(117.49)A.5 F 0.0 PE 0.00 189 339.8 8.25 T 2.0 0.00107 PF 0.00 2.04 A 10.0 PT 117.49 206 F 28.9 PE 0.00 206 339.8 8.25 2VE 1E11 T 38.9 0.00107 PF 5.34 2.04 1B11 = 5.30# A 110.0 PT 122.83 207 F 149.0 PE 0.00 207 339.8 8.25 4VE 2T T 259.0 0.00107 PF 0.28 2.04 1BV A 60.0 PT 123.11 208 ** C = 140 ** 250.0 gpm = Hose F 24.0 PE 0.00 208 589.8 8.27 lUT1 T 84.0 0.00220 PF 0.18 3.52 PT 123.29 296 Bulk Jct K -factor for Cross main 2 = 589.8/(123.29)".5 = 53.12 k Page 27 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY PARKING LEVEL P1 Grid Node Detail Discharge Pressure Outlet Elevation Node (gpm) (psi) K -Value Source (ft) Comments 296 589.8 123.29 K=53.12 CM 2 0.00 Split 297 - 123.34 0.00 298 - 123.32 0.00 299 - 123.52 0.00 300 (589.8) 123.55 Feed Jct 0.00 301 - 123.36 0.00 Page 28 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY PARKING LEVEL P1 Grid Pipe Detail Actual Total Elev Fric Fric Press Press Pipe Diam Len Len Head Flow Loss Loss Vel Nodes @ Beg @ End No. (inch) (Ft) (Ft) (Ft) (Gpm)(Psi/Ft)(Psi)(Fps) Beg End (Psi) (Psi) 295 10.28 60.0 90.0 0.00 -391.3 0.0004 0.03 1.5 298 296 123.32 123.29 Fit= 30.0 lUT1 296 12.34 1090.0 1227.0 0.00 198.5 0.0000 0.05 0.5 296 297 123.29 123.34 Fit= 137.0 2UT1 7UEE 297 10.28 365.0 395.0 0.00 -133.0 0.0000 0.02 0.5 297 298 123.34 123.32 Fit= 30.0 lUT1 298 10.28 1160.0 1191.0 0.00 258.3 0.0002 0.20 1.0 298 299 123.32 123.52 Fit= 31.0 lUE 2UEE 299 12.34 300.0 358.0 0.00 258.3 0.0001 0.02 0.7 299 300 123.52 123.55 Fit= 58.0 lUT1 ]UE 300 12.34 1540.0 1688.0 0.00 -331.5 0.0001 0.18 0.9 300 301 123.55 123.36 Fit= 148.0 4UT1 301 12.34 130.0 188.0 0.00 -331.5 0.0001 0.02 0.9 301 297 123.36 123.34 Fit= 58.0 1UT1 1UE Page 29 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY PARKING LEVEL P1 Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes. Bulk C = 140 ___= A 0.0 PT 123.55 300 Grid Jct 589.8=53.06(123.55)A.5 F 0.0 PE 9.74 (EL= 22.50 ft) 302 589.8 12.34 T 0.0 0.00000 PF 0.00 1.58 PT 133.29 303 Available flow at 133.29 psi is 1683.6 gpm which is 1093.8 gpm from curve. Supply pressure available with 589.8 gpm flowing is 161.73 psi, thus system requirement is 28.44 psi below supply curve. (17.6%) HYDRAULIC CALCULATIONS MCKINSTRY COMPANY Job_ _ DEPT OF HOMELAND SECURITY Occupancy Density Area of Application Coverage per Sprinkler System type_ _ Wet Hose '150.0 gpm Inside - LEVEL 1 ORDINARY HAZARD 0.15 gpm/sq.ft. 1500 square feet 130 S.F. MAX Hose Water Supply _ 166.50 psi Static, 138.00 psi Residual Sprinklers - - K=5.6 Demand_ _ _ _ 127.97 psi ® 561.4 gpm @ B.O.R. 127.97 psi @ 561.4 gpm @ Supply 162.15 psi available @ 561.4 gpm Demand is below curve by 34.18 psi Page 3 0 Date 10/31/03 Job: DHS -L1 @ 1550.0 gpm Page 31 MCKINSTRY COMPANY Description of Fitting abbreviations Code Description T Tee E Ninety degree elbow VT Victaulic tee VE Victaulic ninety degree elbow Bil Backflow: Ames 2000ss/3000ss Silver Bullet BV Butterfly valve CV Swing check valve UE Underground ASCA ninety degree elbow UEE Underground ASCA forty five degree elbow UT1 Underground ASCA tee: flow in run, flow out bullhead only Description of Other abbreviations Code Description AO Arm -over DR Drop BL Branch Line CM Cross Main PT Total pressure PE Pressure loss due to elevation changes PF Pressure loss due to friction .5 Raised to the power of .5 (Square Root) A Actual pipe length F Fitting equivalent pipe length T Total pipe length Page 32 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 1 Raw data previous to any calculations No. Code Diam Length Beg End Nd Kfacl Kfac2 Press Elev Hose HW Vel Fit 120 DR1 1.049 1.0 0 0 5.6 12.00 -1.00 0.0 120 32 lE 121 DR2 1.049 1.0 0 0 5.6 12.00 -1.00 0.0 120 32 1T 122 DR1A 1.049 1.0 0 0 5.6 7.20 -1.00 0.0 120 32 lE 123 A01 1.049 1.0 0 0 DR1A 0.00 0.00 0.0 120 32 1T 124 A02 1.049 1.0 0 0 DR1 0.00 0.00 0.0 120 32 1T 125 BL1 1.416 12.5 0 0 A01 DR1A 0.00 0.00 0.0 120 32 2E 126 BL1 1.416 8.0 0 0 A01 0.00 0.00 0.0 120 32 127 BL1 1.416 9.5 •0 0 A01 0.00 0.00 0.0 120 32 128 BL1 1.416 8.0 0 0 A02 0.00 0.00 0.0 120 32 129 BL1 1.416 12.0 0 0 A02 0.00 0.00 0.0 120 32 130 BL1 1.416 12.0 0 0 A02 0.00 0.00 0.0 120 32 131 BL1 1.416 6.0 0 0 0.00 0.00 0.0 120 32 1T 132 BL2 1.416 10.0 0 0 DR1 DR1A 0.00 0.00 0.0 120 32 133 BL2 1.416 12.0 0 0 DR2 0.00 0.00 0.0 120 32 134 BL2 1.416 12.0 0 0 DR2 0.00 0.00 0.0 120 32 135 BL2 1.416 12.0 0 0 DR2 0.00 0.00 0.0 120 32 136 BL2 1.416 12.0 0 0 DR2 0.00 0.00 0.0 120 32 137 BL2 1.416 6.0 0 0 0.00 0.00 0.0 120 32 1T 138 CM1 2.731 10.0 0 0 BL1 0.00 0.00 0.0 120 32 139 CM1 2.731 10.0 0 0 BL2 0.00 0.00 0.0 120 32 140 CM1 2.731 22.0 0 0 BL2 0.00 0.00 0.0 120 32 1T 141 CM2L 2.731 210.0 0 0 0.00 0.00 0.0 120 32 1VT,2VE 142 CM2L 2.731 218.0 0 0 CM1 0.00 0.00 0.0 120 32 1VT,2VE 143 CM3 3.356 22.0 0 0 CM2L 0.00 0.00 0.0 120 32 2VE,1VT,1CV,1BV 204 CM4 6.357 202.0 0 0 CM3 0.00 0.00 0.0 120 32 2T,2VE,1BV 205 CM4 8.249 54.0 0 0 0.00 15.50 0.0 120 32 206 CM4 8.249 10.0 0 0 0.00 0.00 0.0 120 32 2VE,1B11 207 CM4 8.249 110.0 0 0 0.00 0.00 0.0 120 32 4VE,2T,1BV 208 CM4 8.270 60.0 0 0 0.00 0.00 1.50.0 140 32 lUT1 295 G 10.280 60.0 298 296 0.00 0.00 0.0 140 32 lUT1 296 G 12.340 1090.0 296 297 1 CM4 0.00 0.00 0.0 140 32 2UT1,7UEE Page 33 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 1 Raw data previous to any calculations No. Code Diam Length Beg End Nd Kfacl Kfac2 Press Elev Hose HW Vel Fit 297 G 10.280 365.0 297 298 N 0.00 0.00 0.0 140 32 1UT1 298 G 10.280 1160.0 298 299 N 0.00 0.00 0.0 140 32 ].UE,2UEE 299 G 12.340 300.0 299 300 N 0.00 0.00 0.0 140 32 lUT1,1UE 300 G 12.340 1540.0 300 301 N 0.00 0.00 0.0 140 32 4UT1 301 G 12.340 130.0 301 297 N 0.00 0.00 0.0 140 32 lUT1,1UE 302 BU 12.340 0.0 300 0 0.00 22.50 0.0 140 32 Page 34 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 1 Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Drop i C = 120 A 1.0 PT 12.00 120 19.4=5.60(12.00)A.5 F 2.0 PE -0.43 (EL= -1.00 ft) 120 19.4 1.05 1E T 3.0 0.12299 PF 0.37 7.20 PT 11.94 124 B1 Jct K -factor for drop 1 = 19.4/(11.94)A.5 = 5.62 at Hyd Ref Pts 124 132 Drop 2 C = 120 ______= A 1.0 PT 12.00 121 19.4=5.60(12.00)A.5 F 5.0 PE -0.43 (EL= -1.00 ft) 121 19.4 1.05 1T T 6.0 0.12299 PF 0.74 7.20 PT 12.30 133 B1 Jct K -factor for drop 2 = 19.4/(12.30)A.5 = 5.53 at Hyd Ref Pts 133 134 135 136 Drop lA ______= A 1.0 PT 7.20 122 15.0=5.60(7.20)A.5 F 2.0 PE -0.43 122 15.0 1.05 lE T 3.0 0.07668 PF 0.23 5.5S PT 7.00 123 C = 120 (EL= -1.00 ft) B1 Jct K -factor for drop la = 15.0/(7.00)A 5 = 5.67 at Hyd Ref Pts 123 125 132 Arm -over 1 C = 120 = A 1.0 PT 7.00 123 DR1A 15.0=5.67(7.00)A.5 F 5.0 PE 0.00 123 15.0 1.05 1T T 6.0 0.07643 PF 0.46 5.57 PT 7.46 125 B1 Jct K -factor for arm -over 1 = 15.0/(7.46)A.5 = 5.49 at Hyd Ref Pts 125 126 127 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 1 Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Arm -over 2 = A 1.0 PT 19.4=5.62(11.94)A.5 F 5.0 PE 124 19.4 1.05 1T T 6.0 0.12300 PF PT K -factor for arm -over 2 = 19.4/(12.67)".5 = at Hyd Ref Pts 128 129 130 Branchline No. 1 (Beginning pressure increased due K=11.16=5.49+5.67 A 12.5 30.9=11.16(7.66)A.5 F 6.8 125 30.9 1.42 2E T 19.3 0.06753 A 8.0 F 0.0 126 47.4 1.42 T 8.0 0.14871 A 9.5 17.5=5.49(10.15)A.5 F 0.0 127 64.9 1.42 T 9.5 0.26614 A 8.0 19.4=5.45(12.68)A.5 F. 0.0 128 84.3 1.42 T 8.0 0.43194 A 12.0 21.9=5.45(16.14)A.5 F 0.0 129 106.2 1.42 T 12.0 0.66218 A 12.0 26.8=5.45(24.08)".5 F 0.0 130 132.9 1.42 T 12.0 1.00346 A 6.0 F 6.8 131 132.9 1.42 1T T 12.8 1.00346 16.5=5.49(8.97)A.5 PT PE PF PT PE PF PT PE PF PT PE PF PT PE PF PT PE PF PT PE PF PT 11.94 124 0.00 0.74 12.67 128 5.45 to Hyd Ref 7.66 125 0.00 1.30 8.97 126 0.00 1.19 10.15 127 0.00 2.53 12.68 128 0.00 3.46 16.14 129 0.00 7.95 24.08 130 0.00 12.04 36.13 131 0.00 12.84 48.97 138 7.20 Page 35 Notes C = 120 DR1 B1 Jct Pt 128) C = 120 AO1 + DR1A 6.30 9.65 13.21 17.17 21.63 27.08 27.08 K -factor for branchline no. 1 = 132.9/(48.97)A.5 = 18.99 AO1 A01 A02 A02 A02 Cross main Jct Page 36 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY -LEVEL 1 Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Branchline No. 2 C = 120 ______= K=11.29=5.62+5.67 A 10.0 PT 11.94 132 DR1 + DR1A 39.0=11.29(11.94)''.5 F 0.0 PE 0.00 132 39.0 1.42 T 10.0 0.10382 PF 1.04 7.94 A 12.0 PT 12.97 133 DR2 19.9=5.53(12.97)A.5 F 0.0 PE 0.00 133 58.9 1.42 T 12.0 0.22277 PF 2.67 12.00 A 12.0 PT 15.65 134 DR2 21.9=5.53(15.65)A.5 F 0.0 PE 0.00 134 80.8 1.42 T 12.0 0.39956 PF 4.79 16.46 A 12.0 PT 20.44 135 DR2 25.0=5.53(20.44)A.5 F 0.0 PE 0.00 135 105.8 1.42 T 12.0 0.65800 PF 7.90 21.55 A 12.0 PT 28.34 136 DR2 29.5=5.53(28.34)".5 F 0.0 PE 0.00 136 135.2 1.42 T 12.0 1.03631 PF 12.44 27.55 A 6.0 PT 40.77 137 F 6.8 PE 0.00 137 135.2 1.42 1T T 12.8 1.03631 PF 13.26 27.55 PT 54.04 139 Cross main Jct K -factor for branchline no. 2 = 135.2/(54.04)'.5 = 18.39 at Hyd Ref Pts 139 140 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 1 Pipe Flow Dia Fitting Length Fr Loss No (gpm) (inch) and Dev (ft) (psi/ft) Cross main 1 (Beginning pressure A 139.0=18.99(53.59)A.5 F 138 139.0 '2.73 T A 135.2=18.39(54.04)A.5 F 139 274.2 2.73 T A 137.2=18.39(55.60)A.5 F 140 411.4 2.73 1T T = increased due 10.0 0.0 10.0 0.04452 10.0 0.0 10.0 0.15642 22.0 19.6 41.6 0.33121 Press Hyd Vel (psi) Ref (fps) to Hyd Ref Pt 139) PT 53.59 138 PE 0.00 PF 0.45 7.61 PT 54.04 139 PE 0.00 PF 1.56 15 02 PT 55.60 140 PE 0.00 PF 13.78 22.53 PT 69.39 142 Cross K -factor for Cross main 1 = 411.4/(69.39)A.5 = 49.39 Clockwise (K -Factor @ split=49.39 from CM1) A 218.0 PT F 32.7 PE 142 203.9 2.73 1VT 2VE T 250.7 0.09040 PF PT ========= Counter -Clockwise (K -Factor @ split=49.39 from CM1) A 210.0 PT 69.39 142 F 32.7 PE 0.00 141 207.5 2.73 1VT 2VE T 242.7 0.09338 PF 22.66 11.37 PT 92.05 143 69.39 142 0.00 22.66 92.05 143 11.17 Cross main 3 = (Balance Accuracy = A 22.0 PT 75.9 PE 97.9 0.12142 PF PT 411.4=42.88(92.05)A.5 F 143 411.4 3.36 2VE 1VT T 1CV 1BV 92.05 - Page 37 Notes C = 120 BL1 BL2 BL2 main Jct C = 120 Split Point Loop Jct C = 120 Split Point Loop Jct 92.05 = 0.00) 92.05 143 0.00 11.88 14.92 103.93 204 Cross main Jct C = 120 Loop Jct K -factor for Cross main 3 = 411.4/(103.93)x.5 = 40.36 Page 38 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 1 Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Cross main 4 C = 120 A 202.0 PT 103.93 204 CM 3 411.4=40.36(103.93)'.5 F 113.2 PE 0.00 204 411.4 6.36 2T 2VE T 315.2 0.00541 PF 1.71 4.16 1BV A 54.0 PT 105.63 205 F 0.0 PE 6.71 (EL= 15.50 ft) 205 411.4 8.25 T 54.0 0.00152 PF 0.08 2.47 A 10.0 PT 112.43 206 F 28.9 PE 0.00 206 411.4 8.25 2VE 1B11 T 38.9 0.00152 PF 5.00 2.47 1B11 = 4.94# A 110.0 PT 117.43 207 F 149.0 PE 0.00 207 411.4 8.25 4VE 2T T 259.0 0.00152 PF 0.39 2.47 1BV A 60.0 PT 117.82 208 ** C = 140 ** 150.0 gpm = Hose F 24.0 PE 0.00 208 561.4 8.27 lUT1 T 84.0 0.00201 PF 0.17 3.35 PT 117.99 296 Bulk Jct K -factor for Cross main 4 = 561.4/(117.99)#.5 = 51.68 Page 39 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 1 Grid Node Detail Discharge Pressure Outlet Elevation Node (gpm) (psi) K -Value Source (ft) Comments = = _____ 296 561.4 117.99 K=51.68 CM 4 0.00 Split 297 - 118.04 0.00 298 - 118.02 0.00 299 - 118.20 0.00 300 (561.4) 118.22 Feed Jct 0.00 301 - 118.06 0.00 Page 40 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 1 Grid Pipe Detail Actual Total Elev Fric Fric Press Press Pipe Diam Len Len Head Flow Loss Loss Vel Nodes @ Beg @ End No. (inch) (Ft) (Ft) (Ft) (Gpm)(Psi/Ft)(Psi)(Fps) Beg End (Psi) (Psi) -= 295 10.28 60.0 90.0 0.00 -372.5 0.0003 0.03 1.4 298 296 118.02 117.99 Fit= 30.0 IUT1 296 12.34 1090.0 1227.0 0.00 188.9 0.0000 0.05 0.5 296 297 117.99 118.04 Fit= 137.0 2UT1 7UEE 297 10.28 365.0. 395.0 0.00 -126.6 0.0000 0.02 0.5 297 298 118.04 118.02 Fit= 30.0 lUT1 298 10.28 1160.0 1191.0 0.00 245.9 0.0002 0.18 1.0 298 299 118.02 118.20 Fit= 31.0 1UE 2UEE 299 12.34 300.0 358.0 0.00 245.9 0.0001 0.02 0.7 299 300 118.20 118.22 Fit= 58.0 lUT1 lUE 300 12.34 1540.0 1688.0 0.00 -315.5 0.0001 0.17 0.8 300 301 118.22 118.06 Fit= 148.0 4UT1 301 12.34 130.0 188.0 0.00 -315.5 0.0001 0.02 0.8 301 297 118.06 118.04 Fit= 58.0 lUT1 lUE Page 41 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 1 Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Bulk 561.4=51.63(118.22)A 302 561.4 12.34 C = 140 A 0.0 PT 118.22 300 Grid Jct 5 F 0.0 PE 9.74 (EL= 22.50 ft) T 0.0 0.00000 PF 0.00 1.51 PT 127.97 303 Available flow at 127.97 psi is 1824.4 gpm which is 1263.0 gpm from curve. Supply pressure available with 561.4 gpm flowing is 162.15 psi, thus system requirement is 34.18 psi below supply curve. (21.1%) Page 42 HYDRAULIC CALCULATIONS MCKINSTRY COMPANY Date 10/31/03 Job: DHS -L4 Job_ _ DEPT OF HOMELAND SECURITY - LEVEL 4 TUKWILA, WASHINGTON Occupancy ORDINARY HAZARD Density 0.15 gpm/sq.ft. Area of Application 1500 square feet Coverage per Sprinkler 130 S.F. MAX System type_ _ Wet Hose 250.0 gpm Inside Hose Water Supply _ 166.50 psi Static, 138.00 psi Residual @ 1550.0 Sprinklers - - K=5.6 Demand_ _ _ _ 141.08 psi @ 668.6 gpm @ B.O.R. 141.08 psi @ 668.6 gpm @ Supply 160.48 psi available @ 668.6 gpm Demand is below curve by 19.40 psi gpm • Page 43 MCKINSTRY COMPANY Description of Fitting abbreviations Code Description T Tee E Ninety degree elbow VT Victaulic tee VE Victaulic ninety degree elbow Bil Backflow: Ames 2000ss/3000ss Silver Bullet BV Butterfly valve CV Swing check valve UE Underground ASCA ninety degree elbow UEE Underground ASCA forty five degree elbow UT1 Underground ASCA tee: flow in run, flow out bullhead only Description of Other abbreviations Code Description DR Drop BL Branch Line CM Cross Main PT Total pressure PE Pressure loss due to elevation changes PF Pressure loss due to friction A.5 Raised to the power of .5 (Square Root) A Actual pipe length F Fitting equivalent pipe length T Total pipe length Page 44 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 4 TUKWILA, WASHINGTON Raw data previous to any calculations No. Code Diam Length Beg End Nd Kfacl Kfac2 Press Elev Hose HW Vel Fit 1 DR1 1.049 1.0 0 0 5.6 12.00 -1.00 0.0 120 32 1T 2 DR2 1.049 1.0 0 0 5.6 7.00 -1.00 0.0 120 32 lE 3 BL1 1.416 12.5 0 0 DR2 DR2 0.00 0.00 0.0 120 32 2E 4 BL1 1.416 12.0 0 0 DR1 0.00 0.00 0.0 120 32 5 BL1 1.416 12.0 0 0 DRi 0.00 0.00 0.0 120 32 6 BL1 1.416 12.0 0 0 DR1 0.00 0.00 0.0 120 32 7 BL1 1.416 6.0 0 0 0.00 0.00 0.0 120 32 1T 8 BL2 1.416 10.0 0 0 DR2 DR2 0.00 0.00 0.0 120 32 9 BL2 1.416 12.0 0 0 DR1 0.00 0.00 0.0 120 32 10 BL2 1.416 12.0 0 0 DRI 0.00 0.00 0.0 120 32 11 BL2 1.416 12.0 0 0 DR1 0.00 0.00 0.0 120 32 12 BL2 1.416 12.0 0 0 DRi 0.00 0.00 0.0 120 32 13 BL2 1.650 6.0 0 0 0.00 0.00 0.0 120 32 1T 14 PC2 0.000 0.0 0 0 BL2 2/5 . 0.00 0.00 0.0 120 32 15 CM1 2.731 6.0 0 0 BL1 0.00 0.00 0.0 120 32 16 CM1 2.731 10.0 0 0 BL1 0.00 0.00 0.0 120 32 17 CM1 2.731 10.0 0 0 BL2 0.00 0.00 0.0 120 32 18 CM1 2.731 12.0 0 0 PC2 0.00 0.00 0.0 120 32 IT 19 CM2L 2.731 210.0 0 0 0.00 0.00 0.0 120 32 1VT,2VE 20 CM2L 2.731 232.0 0 0 CM1 0.00 0.00 0.0 120 32 1VT,2VE 21 CM3 3.356 22.0 0 0 CM2L 0.00 5.50 0.0 120 32 2VE,1VT,1CV,1BV 201 CM4 6.357 13.0 0 0 CM3 0.00 13.00 100.0 120 32 202 CM4 6.357 13.0 0 0 0.00 13.00 0.0 120 32 203 CM4 6.357 15.0 0 0 0.00 15.00 0.0 120 32 204 CM4 6.357 202.0 0 0 0.00 0.00 0.0 120 32 2T,2VE,1BV 205 CM4 8.249 54.0 0 0 0.00 15.50 0.0 120 32 206 CM4 8.249 10.0 0 0 0.00 0.00 0.0 120 32 2VE,1B11 207 CM4 8.249 110.0 0 0 0.00 0.00 0.0 120 32 4VE,2T,1BV 208 CM4 8.270 60.0 0 0 0.00 0.00 150.0 140 32 lUTl 295 G 10.280 60.0 298 296 0.00 0.00 0.0 140 32 1UT1 296 G 12.340 1090.0 296 297 1 CM4 0.00 0.00 0.0 140 32 2UT1,7UEE Page 45 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 4 TUKWILA, WASHINGTON Raw data previous to any calculations No. Code Diam Length Beg End Nd Kfacl Kfac2 Press Elev Hose HW Vel Fit 297 G 10.280 365.0 297 298 N 0.00 0.00 0.0 140 32 lUT] 298 G 10.280 1160.0 298 299 N 0.00 0.00 0.0 140 32 lUE,2UEE 299 G 12.340 300.0 299 300 N 0.00 0.00 0.0 140 32 1UT1,1UE 300 G 12.340 1540.0 300 301 N 0.00 0.00 0.0 140 32 4UT1 301 G 12.340 130.0 301 297 N 0.00 0.00 0.0 140 32 lUT1,1UE 302 BU 12.340 0.0 300 0 0.00 22.50 0.0 140 32 Page 46 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 4 TUKWILA, WASHINGTON Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Drop 1 C = 120 A 1.0 PT 12.00 1 19.4=5.60(12.00)A.5 F 5.0 PE -0.43 (EL= -1.00 ft) 1 19.4 1.05 1T T 6.0 0.12299 PF 0.74 7.20 PT 12.30 4 B1 Jct K -factor for drop 1 = 19.4/(12.30)".5 = 5.53 at Hyd Ref Pts 4 5 6 9 10 11 12 Drop 2 ______= A 1.0 PT 7.00 2 14.8=5.60(7.00)A.5 F 2.0 PE -0.43 2 14.8 1.05 1E T 3.0 0.07470 PF 0.22 5.50 PT 6.79. 3 K -factor for drop 2 = 14.8/(6.79)A.5 = 5.68 at Hyd Ref Pts 3 8 C = 120 (EL= -1.00 ft) B1 Jct Branchline No. 1 (Beginning pressure increased due to Hyd Ref Pt 4) C = 120 K=11.36=5.68+5.68 A 12.5 PT 10.51 3 DR2 + DR2 36.8=11.36(10.51)A.5 F 6.8 PE 0.00 3 36 8 1.42 2E T 19.3 0.09341 PF 1.80 7.50 A 12.0 PT 12.31 4 DR1 19.4=5.53(12.31)A.5 F 0.0 PE 0.00 4 56.2 1.42 T 12.0 0.20440 PF 2.45 11.46 A 12.0 PT 14.77 5 DR1 21.3=5.53(14.77)A.5 F 0.0 PE 0.00 5 77.5 1.42 T 12.0 0.36988 PF 4.44. 15.79 A 12.0 PT 19.21 6 DR1 24.2=5.53(19.21)''.5 F 0.0 PE 0.00 6 101.7 1.42 T 12.0 0.61195 PF 7.34 20.72 A 6.0 PT 26.55 7 F 6.8 PE 0.00 7 101.7 1.42 1T T 12.8 0.61195 PF 7.83 20.72 PT 34.38 15 Cross main Jct K -factor for branchline no. 1 = 101.7/(34.38)".5 = 17.34 at Hyd Ref Pts 15 16 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 4 TUKWILA, WASHINGTON Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Page 47 Notes Branchline No. 2 (Beginning pressure increased due to Hyd Ref Pt 9) C = 120 == K=11.36=5.68+5.68 A 10.0 PT 11.31 8 DR2 + DR2 38.2=11.36(11.31)A.5 F 0.0 PE 0.00 8 38.2 1.42 T 10.0 0.09993 PF 1.00 7.78 A 12.0 PT 12.31 9 DR1 19.4=5.53(12.31)A.5 F 0.0 PE 0.00 9 57.6 1.42 T 12.0 0.21366 PF 2.56 11.73 A 12.0 PT 14.87 10 DR1 21.3=5.53(14.87)A.5 F 0.0 PE 0.00 10 78.9 1.42 T 12.0 0.38267 PF 4.59 16.08 A 12.0 PT 19.46 11 DR1 24.4=5.53(19.46)A.5 F 0.0 PE 0.00 11 103.3 1.42 T 12.0 0.62987 PF 7.56 21.05 A 12.0 PT 27.02 12 DRI 28.8=5.53(27.02)A.5 F 0.0 PE 0.00 12 132.1 1.42 T 12.0 0.99194 PF 11.90 26.91 A 6.0 PT 38.92 13 F 9.0 PE 0.00 13 132.1 1.65 1T T 15.0 0.47099 PF 7.07 19.82 PT 46.00 17 Cross main Jct K -factor for branchline no. 2 = 132.1/(46.00)A.5 = 19.48 at Hyd Ref Pts 17 18 • MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 4 TUKWILA, WASHINGTON Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Page 48 Notes Cross main 1 (Beginning pressure increased due to Hyd Ref Pt 17) C = 120 A 6.0 PT 44.66 15 BL1 115.9=17.34(44.66)".5 F 0.0 PE 0.00 15 115.9 2.73 T 6.0 0.03180 PF 0.19 6.35 A 10.0 PT 44.85 16 BL1 116.2=17.34(44.85)A.5 F 0.0 PE 0.00 16 232.1 2.73 T 10.0 0.11486 PF 1.15 12.71 A 10.0 PT 46.00 17 BL2 132.1=19.48(46.00)".5 F 0.0 PE 0.00 17 364.2 2.73 T 10.0 0.26436 PF 2.64 19.95 A 12.0 PT 48.65 18 2/5*BL2 54.3=7.79(48.65)".5 F 19.6 PE 0.00 18 418.5 2.73 1T T 31.6 0.34192 PF 10.81 22.92 PT 59.45 20 Cross main Jct K -factor for Cross main 1 = 418.5/(59.45)".5 = 54.28 Clockwise (K -Factor @ split=54.28 from CM1) C = 120 A 232.0 PT 59.46 20 Split Point F 32.7 PE 0.00 20 204.4 2.73 1VT 2VE T 264.7 0.09077 PF 24.02 11.19 PT 83.48 21 Loop Jct Counter -Clockwise (K -Factor @ split=54.28 from CM1) C = 120 A 210.0 PT 59.46 20 Split Point F 32.7 PE 0.00 19 214.2 2.73 1VT 2VE T 242.7 0.09900 PF 24.02 11.73 PT 83.48 21 Loop Jct. (Balance Accuracy = 83.48 - 83.48 = 0.00) Cross main 3 C = 120 A 22.0 PT 83.48 21 Loop Jct 418.6=45.82(83.48)".5 F 75.9 PE 2.38 (EL= 5.50 ft) 21 418.6 3.36 2VE 1VT T 97.9 0.12538 PF 12.27 15.18 ICV 1BV PT 98.13 201 Cross main Jct K -factor for Cross main 3 = 418.6/(98.13)A.5 = 42.26 Page 49 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 4 TUKWILA, WASHINGTON Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Cross main 4 C = 120 __ ___= A 13.0 PT 98.13 201 CM 3 418.6=42.26(98.13)A.5 F 0.0 PE 5.63 (EL= 13.00 ft) 201 518.6 6.36 T 13.0 0.00830 PF 0.11 5.24 A 13.0 PT 103.87 202 F 0.0 PE 5.63 (EL= 13.00 ft) 202 518.6 6.36 T 13.0 0.00830 PF 0.11 5.24 A 15.0 PT 109.60 203 F 0.0 PE 6.50 (EL= 15.00 ft) 203 518.6 6.36 T 15.0 0.00830 PF 0.12 5.24 A 202.0 PT 116.22 204 F 113.2 PE 0.00 204 518.6 6.36 2T 2VE T 315.2 0.00830 PF 2.62 5.24 1BV A 54.0 PT 118.84 205 F 0.0 PE 6.71 (EL= 15.50 ft) 205 518.6 8.25 T 54.0 0.00233 PF 0.13 3.2.1 A 10.0 PT 125.68 206 F 28.9 PE 0.00 206 518.6 8.25 2VE 1B11 T 38.9 0.00233 PF 4.50 3.11 1B11 = 4.41# A 110.0 PT 130.18 207 F 149.0 PE 0.00 207 518.6 8.25 4VE 2T T 259.0 0.00233 PF 0.60 3.11 1BV A 60.0 PT 130.78 208 ** C = 140 ** 150.0 gpm = Hose F 24.0 PE 0.00 208 668.6 8.27 lUT1 T 84.0 0.00277 PF 0.23 3.99 PT 131.01 296 Bulk Jct K -factor for Cross main 4 = 668.6/(131.01)A.5 = 58.41 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 4 TUKWILA, WASHINGTON Grid Node Detail Discharge Pressure Outlet (psi) K -Value Source Node (gpm) _ ====== == Page 50 Elevation (ft) Comments _ ====.x 296 668.6 131.01 K=58.41 CM 4 0.00 Split 297 - 131.08 0.00 298 - 131.06 0.00 299 - 131.30 0.00 300 (668.6) 131.33 Feed Jct 0.00 301 - 131.10 0.00 Pipe Diam No. (inch) = = MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations Actual Len (Ft) DEPT OF HOMELAND SECURITY - LEVEL 4 TUKWILA, WASHINGTON Grid Pipe Detail Total Len (Ft) Elev Head (Ft) Fric Flow Loss (Gpm)(Psi/Ft) =5= -====-==-=_= 295 10.28 60.0 Fit= 30.0 296 12.34 1090.0 Fit= 137.0 297 10.28 365.0 Fit= 30.0 298 10.28 1160.0 Fit= 31.0 299 12.34 300.0 Fit= 58.0 300 12.34 1540.0 Fit= 148.0 301 12.34 130.0 Fit= 58.0 90.0. 0.00 lUT1 1227.0 0.00 2UT1 7UEE 395.0 0.00 lUT1 1191.0 0.00 lUE 2UEE 358.0 0.00 lUT1 lUE 1688.0 0.00 4UT1 188.0 0.00 lUT1 lUE -443.6 225.0 -150.7 292.9 292.9 -375.7 -375.7 =_= Page 51 Fric Press Press Loss Vel Nodes ® Beg 0 End (Psi)(Fps) Beg End (Psi) (Psi) =___==__=__ 0.0005 0.04 1.7 298 296 131.06 131.01 0.0001 0.06 0.6 296 297 131.01 131.08 0.0001 0.02 0.6 297 298 131.08 131.06 0.0002 0.25 1.1 298 299 131.06 131.30 0.0001 0.03 0.8 299 300 131.30 131.33 0.0001 0.23 1.0 300 301 131.33 131.10 0.0001 0.03 1.0 301 297 131.10 131.08 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 4 TUKWILA, WASHINGTON Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Bulk 668.6=58.34(131.33)A.5 302 668.6 12.34 Page 52 Notes C = 140 A 0.0 PT 131.33 300 Grid Jct F 0.0 PE 9.74 (EL= 22.50 ft) T 0.0 0.00000 PF 0.00 1.79 PT 141.08 303 Available flow at 141.08 psi is 1457.1 gpm which is 788.5 gpm from curve. Supply pressure available with 668.6 gpm flowing is 160.48 psi, thus system requirement is 19.40 psi below supply curve. (12.1%) e `'3 tv. 13 t ZCc y NAC Circuit Load & Voltage Drop Calculation Storage P311 Parking level 3 APS -1 Candella Amps Circuit Number Ckt 1 Ckt 2 Ckt 3 Ckt 4 11 12 13 14 Notifier Speaker Strobes SP2W2415:r:e SP2W2430 m 30 0.080 SP2W2475 SP2W24110 WP Horn Strobe P12241575K 110 0.130 5 5 2 `-:_ 7 W 0..,'` ' ;�; '� Notifier Strobes S1224MC S1224MC S1224MC S1224MC WP Strobe S241575K 15 0.038 : .3 o r .;® 75 0.090 5e -n': -0-„,4,8 ,, 15-75 0.043 Notifier Speaker Strobes SP2C2415 Ceiling SP2C2430 � : r^� 30 0.079 , _ 1 SP2C2475 SP2C2495 95 0.173 Notifier Strobes SC2415W Ceiling SC2430W SC2475W SC2495W i.4. 30 0.079 Misc WP Bell MDL sync mod " 'E Yi 0.017 Circuit Circuit # Devices 11 10 8 0 Circuit Amps 1.004 0.972 0.731 0.000 Length (ft)(14awg) 392 427 256 0 Length (ft)(12awg) 0 0 0 0 EOL Voltage (14awg) 21.93 21.82 23.02 24.00 EOL Voltage (12awg) 24.00 24.00 24.00 24.00 Parking Level 1 APS -2 NAC Circuit Load & Voltage Dro • Calculation Notifier Speaker Strobes WP Horn Strobe SP2W2415 SP2W2430 SP2W2475 SP2W24110 P12241575K Notifier Strobes WP Strobe S1224MC S1224MC S1224MC S1224MC S241575K Notifier Speaker Strobes Ceiling SP2C2415 SP2C2430 SP2C2475 SP2C2495 Notifier Strobes Ceiling SC2415W SC2430W SC2475W SC2495W Misc WP Bell MDLs cmod Candella Amps Circuit Number Ckt 1 Ckt 2 Ckt 3 Ckt 4 110 0.130 15 0.038 75 0.090 15-75 0.043 30 0.079 95 0.173 30 0.079 21 4 22 4 23 4 24 4 EstiWZ 0.017 # Devices Circuit Amps Circuit Length (ft)(14awg) Circuit Length (ft)(12awg) EOL Voltage (14awg) EOL Voltage (12awg) 7 0.698 276 0 22.99 24.00 7 0.792 224 0 23.07 24.00 7 0.698 272 0 23.00 24.00 6 0.690 317 0 22.85 24.00 X11Jd oQ-521 NAC Circuit Load & Voltage Drop Calculation Fir 1 Elect rm 110 APS -3 Candella Amps Circuit Number Ckt 1 Ckt 2 Ckt 3 Ckt 4 31 32 33 34 Notifier Speaker Strobes SP2W2415 SP2W2430 SP2W2475 SP2W24110 WP Horn Strobe P12241575K 0 30 0.080 1 a 110 0.130 SP2W2475 SP2W24110 WP Hom Strobe P12241575K ,' �.r;� 110 0.130 ,; aFs _t 0 s �;� ,r ;;;t w Notifier Strobes S1224MC S1224MC S1224MC S1224MC WP Strobe S241575K 15 0.038 1 , w . ~re .t`• -- -. {1 ��-n< 75 0.090 Notifier Strobes S1224MC S1224MC S1224MC S1224MC WP Strobe S241575K 110 _ ``0.118.. .. .. ,ffiJ• 75 0.090 • ' � ,<. �' 15-75 0.043 ; e 15-75 0.043 Notifier Speaker Strobes SP2C2415 Ceiling SP2C2430 16 N>,. r 30 0.079 1$ sd e 30 0.079 4 4 SP2C2475 SP2C2495 t g;< 95 0.173 $ vt,�a.,`�..;« ,11,#. —0 �� -z� Notifier Strobes SC2415W Ceiling SC2430W SC2475W SC2495W ;1 95 0.173 30 0.079 Notifier Strobes SC2415W Ceiling SC2430W SC2475W SC2495W t,,° ,, �,Q 30 0.079 _,;F 7 s t4 e 4 , :'" 4 ) ;; .° 95 0.173 Misc WP Bell MDL sync mod 'r_; $ 95 0.173 1 > e b Misc WP Bell MDL sync mod '' rr y� .... e TO ,`..v. 4 ; e 9+ 'n�..� M 0.0170. ,� 0.017 Circuit Circuit # Devices Circuit Amps 8 6 7 0 1.035 0.802 0.481 0.000 Length (ft)(14awg) Length (ft)(12awg) 515 560 467 477 0 0 0 0 EOL Voltage (14awg) 21.20 21.64 24.00 24.00 EOL Voltage (12awg) 24.00 24.00 24.00 24.00 NAC Circuit Load & Voltage Drop Calculation Fir 2 Elect rm 210 APS -4 Candella Amps Circuit Number Ckt 1 Ckt 2 Ckt 3 Ckt 4 41 42 43 44 Notifier Speaker Strobes SP2W2415 SP2W2430 s '0 :elle,* q, 30 0.080 SP2W2475 SP2W24110 WP Hom Strobe P12241575K ,' �.r;� 110 0.130 -, w 1 , w . ~re .t`• -- -. Y, Notifier Strobes S1224MC S1224MC S1224MC S1224MC WP Strobe S241575K 15 0�...0^38 .. .. ,ffiJ• 75 0.090 • ' � ,<. �' a a ; e 15-75 0.043 Notifier Speaker Strobes SP2C2415 Ceiling SP2C2430 1$ sd e 30 0.079 4 2 SP2C2475 SP2C2495 ,11,#. —0 �� -z� 95 0.173 Notifier Strobes SC2415W Ceiling SC2430W SC2475W SC2495W t,,° ,, �,Q 30 0.079 _,;F : 3• ` e _F 95 0.173 1 3 4 Misc WP Bell MDL sync mod '' rr y� .... K 4 ; e 9+ 'n�..� M rm. ,� 0.017 # Devices Circuit Amps Circuit Length (ft)(14awg) Circuit Length (ft)(12awg) EOL Voltage (14awg) EOL Vottage (12awg) 7 6 10 0 0.599 0.732 1.022 0.000 299 467 477 0 0 0 0 23.06 22.20 21.44 24.00 24.00 24.00 24.00 24.00 NAC Circuit Load & Voltage Drop Calculation Fir 3 Elect rm 310 APS -5 Candella Amps Circuit Number Ckt 1 Ckt 2 Ckt 3 Ckt 4 51 52 53 54 Notifier Speaker Strobes WP Horn Strobe SP2W2415 SP2W2430 0 {1} 30 0.080 1 SP2W24751 SP2W24110 P12241575K 110 0.130 447t E t7. sr a� F...t.. :< Notifier Strobes WP Strobe S1224MC S1224MC S1224MC S1224MC S241575K 15 0.038 , ;, Agit` 1a s Sd, 75 0.090 1„ 15-75 0.043 Notifier Speaker Strobes Ceiling SP2C2415 SP2C2430 z . O.C' 30 0.079 � 2 SP2C2475 SP2C2495 :.e t .y fy. 95 0.173 Notifier Strobes Ceiling SC2415W SC2430W SC2475W SC2495W ;et 30 0.079 2 .., ;14 95 0.173 4 4 5 4 Misc WP Bell p 'k0 ,-:a:. MDL sync mod 0.017 Circuit Circuit # Devices Circuit Amps 8 7 8 10 0.960 0.905 1.030 1.047 Length (ft)(14awg) 528 288 459 617 Length (ft)(12awg) 0 0 0 0 EOL Voltage (14awg) 21.34 22.63 21.52 20 50„ EOL Voltage (12awg) 24.00 24.00 24.00 24.00 Bat Calc form Name Panel & Location Battery Back up Calculation Total Total Item Qty Part # Description Standby Alarm Standby Alarm 1 1 NSF -640 Fire Alarm Control Panel 0.230000 0.230000 0.230000 0.230000 2 1 KDM-2 NSF -640 Fire Alarm Control Panel Display 0.040000 0.094000 0.040000 0.094000 3 1 CRM -4 Control Relay Module 0.007000 0.072000 0.007000 0.072000 4 3 DCM-4RK dual circuit module 0.007000 0.072000 0.021000 0.216000 5 1 APS -6R Aux Power Supply 0.014000 0.000000 0.014000 0.000000 6 2 XP6-C Remote Transponder Module 0.000225 0.035000 0.000450 0.070000 7 24 NBG-12LX Manual Pull Station 0.000270 0.000270 0.006480 0.006480 8 1 AMG -1 Audio Message Generator 0.060000 0.060000 0.060000 0.060000 9 2 AA -120 Amplifier 120 watt 0.051000 7.300000 0.102000 14.600000 10 1 SCS -8 Smoke Control Master Module 0.062000 0.050000 0.062000 0.050000 11 54 FSD-751RP Intelligent Photoelectric Duct Smoke Detector 0.026300 0.087000 1.420200 4.698000 12 5 FMM-1 Intelligent Monitor Module 0.000400 0.005100 0.002000 0.025500 13 17 FDM-1 Dual Circuit Intelligent Monitor Module 0.000750 0.005700 0.012750 0.096900 14 8 FRM-1 Intelligent Relay Module 0.000270 0.005100 0.002160 0.040800 15 21 FCM-1 Intelligent Control Module (NAC) 0.000390 0.005100 0.008190 0.107100 16 35 FSP -851 Intelligent Photoelectric Smoke Detector Ip 0.000360 0.006500 0.012600 0.227500 17 19 MR -201C Aux Relay 0.000000 0.035000 0.000000 0.665000 18 0.000000 0.000000 19 0.000000 0.000000 20 0.000000 0.000000 21 0.000000 0.000000 22 0.000000 0.000000 23 0.000000 0.000000 24 0.000000 0.000000 25 0.000000 0.000000 26 0.000000 0.000000 27 0.000000 0.000000 28 0.000000 0.000000 29 0.000000 0.000000 2.000830 21.259280 Standby Current Total Hours = 2.000830 X 24 = 48.019920 (Hours) Alarm Current Total Minutes = 21.259280 X .083 = 1.764520 (5 Mins) Total = 49.784440 20% Battery Depletion = 9.956888 Total AH Rated Batteries Needed = 59.741328 Total AH Rated Batteries Supplied 1 60 Page 1 INS Battery Back up Calculation APS -1 Pkg level 3 Item Qty Part # 1 1 FCPS-24S6 2 4 SP2W2475 3 12 SP2W24110 4 8 SP2C2415 5 1 SP2C2430 6 4 SC2415 7 8 9 10 11 25 26 27 Description Total Total Standby Alarm Standby Alarm auxiliary power supply 0.032000 0.032000 0.032000 0.032000 speaker strobe 75 cd 0.000000 0.102000 0.000000 0.408000 speaker strobe 110 cd 0.000000 0.130000 0.000000 1.560000 speakerstrobe ceiling 15 cd 0.000000 0.055000 0.000000 0.440000 speakerstrobe ceiling 30 cd 0.000000 0.079000 0.000000 0.079000 strobe, ceiling 15 cd 0.000000 0.055000 0.000000 0.220000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.032000 2.739000 Standby Current Total Hours = 0.032000 X 24 = 0.768000 (Hours) Alarm Current Total Minutes = 2.739000 X .083 = 0.227337 Total (5 Mins) - 0.995337 30% Battery Depletion = 0.298601 Total AH Rated Batteries Needed = 1.293938 Total AH Rated Batteries Supplied 1 INS Battery Back up Calculation APS -2 Pkg level 1 Item Qty Part # 1 1 FCPS-2456 2 3 SP2W2475 3 16 SP2W24110 4 4 SP2C2415 5 4 S1224MC 6 7 8 9 10 11 25 26 27 Description Total Total Standby Alarm Standby Alarm auxiliary power supply 0.032000 0.032000 0.032000 0.032000 speaker strobe 75 cd 0.000000 0.102000 0.000000 0.306000 speaker strobe 110 cd 0.000000 0.130000 0.000000 2.080000 speakerstrobe ceiling 15 cd 0.000000 0.055000 0.000000 0.220000 strobe, 30 cd 0.000000 0.068000 0.000000 0.272000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.032000 2.910000 Standby Current Total Hours = 0.032000 X 24 = 0.768000 (Hours) Alarm Current Total Minutes = 2.910000 X .083 = 0.241530 (5 Mins) Total = 1.009530 30% Battery Depletion = 0.302859 Total AH Rated Batteries Needed = 1.312389 Total AH Rated Batteries Supplied 1 s INS APS -3 Floor 1 Electric Rm 110 Item Qty Part # 1 2 3 4 5 6 7 8 9 10 11 25 26 27 1 FCPS-24S6 3 SP2W2430 16 SP2C2475 4 SP2C2415 4 SP2C2430 2 SC2415 8 SC2495 Battery Back up Calculation Description Total Total Standby Alarm Standby Alarm auxiliary power supply speaker strobe 30 cd speaker strobe, ceiling, 75 cd speakerstrobe ceiling 15 cd speaker strobe, ceiling, 30 cd strobe, ceiling 15 cd strobe, ceiling 95 cd Standby Current Total Hours = Alarm Current Total Minutes Total 30% Battery Depletion Total AH Rated Batteries Needed Total AH Rated Batteries Supplied 0.032000 0.032000 0.032000 0.032000 0.000000 0.080000 0.000000 0.240000 0.000000 0.140000 0.000000 2.240000 0.000000 0.055000 0.000000 0.220000 0.000000 0.079000 0.000000 0.316000 0.000000 0.055000 0.000000 0.110000 0.000000 0.173000 0.000000 1.384000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.032000 4.542000 0.032000 X 24 = 0.768000 (Hours) 4.542000 X .083 = 0.376986 (5 Mins) 1.144986 0.343496 1.488482 INS APS -4 Floor 2 Electric Rm 210 Item Qty Part # Battery Back up Calculation Description Total Total Standby Alarm Standby Alarm 1 1 FCPS-24S6 2 SP2W2430 3 SP2C2475 4 6 SP2C2415 5 6 SP2C2430 6 3 SC2415 7 8 SC2495 8 9 10 11 25 26 27 auxiliary power supply speaker strobe 30 cd speaker strobe, ceiling, 75 cd speakerstrobe ceiling 15 cd speaker strobe, ceiling, 30 cd strobe, ceiling 15 cd strobe, ceiling 95 cd Standby Current Total Hours = Alarm Current Total Minutes = Total 30% Battery Depletion Total AH Rated Batteries Needed Total AH Rated Batteries Supplied 0.032000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.032000 0.080000 0.140000 0.055000 0.079000 0.055000 0.173000 0.032000 X 24 (Hours) 2.385000 X .083 (5 Mins) 0.032000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.032000 0.032000 0.000000 0.000000 0.330000 0.474000 0.165000 1.384000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 2.385000 0.768000 0.197955 0.965955 0.289787 1.255742 J ` M INS APS -5 Floor 3 Electric Rm 310 Item Qty Part # 1 1 2 1 3 4 6 5 2 6 5 7 17 8 2 9 10 11 25 26 27 Battery Back up Calculation Description FCPS-24S6 SP2W2430 SP2C2475 SP2C2415 SP2C2430 SC2415 SC2495 SC2430 auxiliary power supply speaker strobe 30 cd speaker strobe, ceiling, 75 cd speakerstrobe ceiling 15 cd speaker strobe, ceiling, 30 cd strobe, ceiling 15 cd strobe, ceiling 95 cd strobe, ceiling 30 cd Standby Current Total Hours = Alarm Current Total Minutes = Total 30% Battery Depletion Total AH Rated Batteries Needed Total AH Rated Batteries Supplied Total Total Standby Alarm Standby Alarm 0.032000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.032000 0.080000 0.140000 0.055000 0.079000 0.055000 0.173000 0.079000 0.032000 X 24 (Hours) 3.974000 X .083 (5 Mins) 0.032000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.032000 0.032000 0.080000 0.000000 0.330000 0.158000 0.275000 2.941000 0.158000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 3.974000 0.768000 0.329842 1.097842 0.329353 1.427195 5 41 APS•5 Level 3.04 FCPS24S8 (Aux Booster P5) Output Type »> Part R. Description: Starry: Nips: Cinmit !Centrism: Output #1 NAC Sync 55-1 Output 82 NAC Sync 55-2 Output 03 NAC Sync S5-3 Output 84 NAC Sync S5-4 Total Ory SPSCW Ceiling Speaker wl Strobe set at 15cd 0.0000 0.0710 0 SPSCW Ceiling Speaker wl Strobe set at 30cd 0.0000 0.0960 0 SPSCW Ceiling Speaker wl Strobe set at 75cd 0.0000 0.1530 0 SPSCW Ceiling Speaker wl Strobe set at 95cd 0.0000 0.1760 0 0 SCW Ceiling Strobe set at 15cd ' 0.0000 0.0710 0 SCW Ceiling Strobe set at 30cd 0.0000 0.0960 0 SCW Ceiling Strube set at 75cd 0.0000 0.1530 0 SCW Ceiling Strobe set at 95cd 0.0000 0.1760 0 0 SP2C2415 Ceiling Speaker wl Strobe set at 15cd 0.0000 0.0550 1 5 9 15 SP2C2430 Ceiling Speaker wl Strobe set at 3041 0.0000 0.0790 2 6 5 13 SP2C2475 Ceiling Speaker w/ Strobe set at 75cd 0.0000 0.1400 3 1 4 SP2C2495 Ceiling Speaker w/ Strobe set at 95c4 0.0000 0.1730 0 D SC2415W Ceiling Strobe set at 15cd 0.0000 0.0550 1 2 2 5 SC2430W Ceiling Strobe set at 30cd 0.0000 0.0790 0 SC2475W Ceiling Strobe set at 75cd 0.0000 0.1400 0 SC2495W Ceiling Strobe set at 95cd 0.0000 0.1730 4 5 9 0 Sarres7ArJDeaix. � 0 SaiedPNikvJx: .. 0 S46s0 Waev'ce:: 0 Sckict?hdletihv: 0 Settci AV:Devim • 0 4 Devices per Circuit Total Stanmy Circuit Calculated Mpe (3): Total Alarm Circuit CaluuWled Arps (1): Wire Gauge Used (axg): Circuit Length (fl): Estimated Voltage Drop (dc): Estimated EOL Voltage (dc): 8 5 16 17 46 0.000 0.000 0.000 0.000 Ckt 102 1.825 0.960 0.865 1.279 1.140 14AWG 14AWG 14AWG 14AWG Ckt 384 2419 500 400 500 700 2.50 1.80 3.33 4.15 Total Arps 4.244 21.50 22.20 20.67 19.85 1) Current Draw Measurement based on UL1971, 1633V, FWR Input, High cb 0 Temporal Patton 2) Ouldoat/WP Devices have the same Measured Current Draw as One Indoor Devices and are not listed separately above. 3) When the APS is configured fa 'Doors*, Output 41 shutsdam on loss d AC Power. Therefor no Current Draw is shown BATTERY LOAD CALC for APS -5: Hours Requited: Minutes Required Actual Battery Total Mp Hours Required: Total Mp Minutes Required: Minimus Battery Size Needed Inducing a 30% Battery Depletion: Rated Batteries Supplied: = Total Standby Conant = 0.0000 Backup 24 0.0 1.1 Total Alarm Current:= 4.2440 Nam 15 Size Needed Total AH _ 1.1 1.4 8.0 FCPS Calc of OHS - Tukwilla Engineering Fire.xlsm 1 oft Ni#i llt tsdf}s` Yi1 1 @ J{flJ3'8�8 !€ 08tf"i1�.1t1$1..1 APSBA Level 8 FCPS24-S8 (Aux Booster PS) Output Type >>> Part #: Description: Standy Amps: Circuit Idenafers Output #1 NAC Sync S8-1 Output #2 NAC Sync 58.2 Output #3 NAC Sync 08-3 Output #4 NAC Sync S8-4 Total Oty SPSCW Ceiling Speaker w/ Strobe sot at 15cd 0.0000 0.0710 5 5 SPSCW Ceiling Speaker w/ Strobe set at 30cd 0.0000 0.0960 2 2 SPSCW Ceiling Speaker w/ Strobe set at 75x1 10.0000 0.1530 1 2 SPSCW Ceiliy Speaker wl Strobe set at 95cd 0.0000 0.1760 0 0 SCW Ceiling Strobe set at 15cd 0.0000 0.0710 0 SCW Ceiling Strafe set at 30cd 0A000 0.0960 0 SCW Ceiling Strobe set at 75cd 0.0000 0.1530 0 SCW Ceiling Strobe set at 95cd 0.0000 0.1760 0 0 SP2C2415 Ceiling Speaker wl Strobe set at 15cd ( 0.0000 0.0550 8 8 SP202430 Ceiling Speaker w/ Shote set at 30cd 0.0000 0.0790 3 3 SP2C2475 Ceiling Speaker w/ Strobe sot at 75cd 0.0000 0.1400 1 1 SP2C2495 Ceiling Speaker wl Strobe set at 95cd 0.0000 0.1730 0 0 SC2415W Ceiling Strobe set at 15cd 0.0000 0.0550 1 1 SC2430W Ceiling Strobe sot at 30cd 0.0000 0.0790 0 SC2475W Ceiling Strobe set at 75cd ' 0.0000 0.1400 0 SC2495W Ceiling Strebe set at 95cd 0.0000 0.1730 0 0 SaOc7A+VOa+ice: ' 0 SeteptA,J NU.: "... __... 0 Solar3l V Devta?: .. 0 Sa#etAfV rce' ,... 0 # Devices per Circut Total Staub/ Circut Calculated Arps (3): Total Alarm Circut Calculated Arps (1): W re Gauge Used (awg): Circut Length (9): Estimated Voltage Diop (dc): Estimated EOL Vdtage (dc): 13 9 0 0 22 0.000 0.000 0.000 0.000 Ckt 182 1.725 0.872 0.853 0.000 0.000 14AWG 14AWG ': Salad Sdett'I Ckt 384 0.000 400 400 : 9 0 1.81 1.77 0.00 0.00 Total Arrps 1.725 22.19 2223 24.00 24.00 1) Current Draw Measurement based on: UL1971. 16-33V, FWR Input, High m & Temporal Patten 2) OuldoorANP Devices have the same Measured Current Draw as the Indoor Devices and are not fisted separately above. 3) When the APS is configured for 'Doors', Output #4 stulsdoen on loss of AC Poser. Therefore ro'Stwnty Currant Draw is shown BATTERY LOAD CALC for APSBA: Furs Required: Minutes Required: Actual Battery Total Arp Haas Required: Total Ary Minutes Required Mir4mun Battey Sae Needed Inducing a 30% Battery Depletion: Rated Batteries Supplied: = Total Standby Current: = 0.0000 Backup 24 0.0 Total Alarm Current = 1.7250 Alarm 15 0.4 Size Needed Total AH 0.4 0.6 8.0 FCPS Calc of OHS - Tukwilla Engineering Fire.xlsm 1 of1 APS9A Output Type »> Stanmy Amps: Circuit lowlife Output 01 NAC Sync 09.1 is: Output 92 MC Sync 59.2 Output #3 NAC Sync 59-3 Output #4 NAC Sync 59-4 Total Ory Level 9 FCPS24S8 (Mx Booster P5) Part ft Description: SPSCW Ceiling Speaker w/ Strobe set at 15cd i 0.0000 0.0710 5 5 SPSCW Ceiling Speaker w/ Strobe set at 33rd 0.0000 0.0960 2 2 SPSCW Ceiling Speaker w/ Strobe set at 75cd 0.0000 0.1530 0 SPSCW Ceiling Speaker w/ Strobe set at 95cd 0.0000 0.1760 0 0 SCW Ceiling Strobe set at 15cd 1 0.0000 0.0710 1 1 SCW Ceiling Strobe set at 30cd I 0.0000 0.0960 0 SCW Ceiling Strobe set at 75cd 0.0000 0.1530 0 SCW Ceiling Strobe set at 95cd 0.0000 0.1760 0 0 SP2C2415 Coifing Speaker w/ Strobe set at 15cd 0.0000 0.0550 10 1 3 14 SP2C2430 Ceiling Speaker w100obe set at 30W 0.0000 0.0790 11 2 SP2C2475 Ceiling Speaker w/ Strobe set at 75c1 0.0000 0.1400 1 1 2 SP2C2495 Ceiling Speaker w/ Strobe set at 95cd 0.0000 0.1730 1 1 0 SC2415W Ceiling Strobe set at 15cd 0.0000 0.0550 0 SC2430W Ceiling Strobe set at 30cd 0.0000 0.0790 0 SC2475W Ceiling Strobe set at 75cd I 0.0000 0.1400 0 SC2495W Coling Strobe set at 95cd 0.0000 0.1730 1 2 3 0 Sal Ar.Daoce: 0 o SassciWYoa s: 0 SectA OaeM'cei ,•_ 0 SGko iYitDe fctti ' _ . .... , ... D # Devices per Circuit: Total Stanoby Circuit Calculated Arps (3): Total Alan, Grit Calculated Arps (1): Nice Gage Used (awg): Grit Length (ft): Estimated Voltage Drop (ok): Estimated ECL Voltage (b): 12 10 8 0 30 0.000 0.000 0.000 0.000 Ckt 182 1.615 0.769 0.846 0.903 0.000 14AWG 14AWG 14AWG Select Ckt 384 0.903 500 400 400 0 2.00 1.76 1.88 0.00 Total Arps 2518 22.00 _ 2224 22.12 24.00 1) Current Draw Measurement based an: UL1971, 1633V, FWR Input, High 4o & Temporal Patten 2) OuldoodWP Devices have the sane Measured Current Draw as the Indoor Devices and are not listed separately above. 3) When the APS is configured for 'Docs', Output 94 shutsdovm on loss of AC Power. Therefor no Currant Draw is shown BATTERY LOAD CALC for APS9A: Hours Rewired Minutes Required: Actual Battery Total Amp Hous Rewired Total Amp Minutes Rewired: 4r*von Battery Size Needed: Inducing a 30% Battery Depletion: Rated Batteries Supplied: = Total Stanby Current = 0.0000 Backup 24 0.0 Total Aar Current: = 25180 Alar 15 0.6 Size Needed Total AH 0.6 0.8 8.0 FCPS Calc of DHS - Tukwilla Engineering Fire.xlsm 1 oft AMP -1 Circuit Identifier. Entire Building Control Output» AA420 Watts: Amps: P1003 FCM-1 V1-1 PKG2 FCM-1 V1-2 PKG1 FCM-1 01-3 GAR EL FCM-1 V1-4 FLR1 FCM-1 V1-5 FLR2 FCM-1 Vl-6 FLR3 FCM-1 V1-7 FLR4 FCM4 V141 ELEVS FCM-1 V1-9 FCM-1 V1-10 FCM-1 V1-11 FLR3CORE FCM-1 V1-12 Totalay 118 0.0052 1 4 5 1/4 0.0104 25 12 12 20 12 3 7 22 113 12 0.0208 0 1 0.0416 0 2 0.0832 0 4 0.1664 0 8 0.3328 0 A Devices per Circuit: Total Watts per Circuit Total Amps Calculated per Grant (I =P / V ): Wire Gauge Used (awg): Circuit Length (/1): Estimated Voltage Drc (dc): Speakers set at 25 volt Estimated 001 Valdtage (dc): 25 12 12 1 20 12 37 4 0 0 22 118 6.250 1000 3.000 0.125 5.000 3.000 0.750 1.750 0.500 0.000 0.000 5.500 0.260 0.125 0.125 0.005 0.208 0.125 0.031 0.073 0.021 0.000 0.000 0.229 ��•,-. ,,s 14AWG 14AWG 14AWG 14AWG 14AWG 14AWG 14AWG 14AWG 14AWG 14AWG 14AWG 14AWG 1200 600 600 200 1000 800 700 800 700 '0 '01. 800 1.62 0.39 0.39 0.01 1.08 0.52 0.11 0.30 0.08 0.00 0.00 0.95 Total Watts 28.875 22.38 23.61 23.61 23.99 22.92 23.48 23.89 23.70 23.92 24.00 24.00 23.05 Spkr Calc of DHS - Tukwilla Engineering Firexlsm 1 of FACP PROTECTED ITEM AREA OTY PART NUMBER DESCRIPTION STANDBY ALARM STANDBY ALARM 1 0.0000 0.0000 2 0.0000 0.0000 3 0.0000 0.0000 4 00000 0.0000 5 0.0000 0.0000 6 0.0000 0.0000 7 0.0000 0.0000 8 0.0000 0.0000 9 0.0000 0.0000 10 0.0000 00000 11 0.0000 0.0000 12 0.0000 0.0000 13 0.0000 0.0000 14 0.0000 0.0000 15 0.0000 0.0000 16 0.0000 0.0000 17 0.0000 0.0000 18 0.0000 0.0000 19 0.0000 0.0000 20 0.0000 0.0000 21 0.0000 0.0000 22 0.0000 0.0000 23 0.0000 0.0000 24 0.0000 0.0000 25 0.0000 0.0000 26 0.0000 00000 27 0.0000 0.0000 28 0.0000 0.0000 29 0.0000 0.0000 30 0.0000 0.0000 31 0.0000 0.0000 32 0.0000 0.0000 33 0.0000 0.0000 34 0.0000 0.0000 35 0.0000 0.0000 36 0.0000 0.0000 37 0.0000 0.0000 38 0.0000 0.0000 39 0.0000 0.0000 40 0.0000 0.0000 41 0.0000 0.0000 42 00000 0.0000 43 0.0000 0.0000 44 0.0000 0.0000 45 0.0000 0.0000 Total 51ancby Current: -IAr Total Alarm Current: = TOTAL CURRENT DRAW: 0.0000 0.0000 0.000 Backup Haas Recpred: 24 SSAty Hors Required 0.0 0.000 I Alar Minutes Required: 15 sf Amp Minutes Reglired: 0.0 Minnsn Battery Size Needed: Actual Battey Size Needed Inducing a 30% Battery Depletion: Total AH Rated Batteries Supplied: = 0.0 0.0 26.0 FACP Calc of DHS - Tukvilla Engineering Fire.xlsm 1 of T00•d 'V.OJ For Th fry la Of YourDulkllug January 25, 2012 Plan Review Tukwila Fire Department 444 Andover Park East Tukwila, WA 98188 Re: DHS, 12500 Tukwila Int. BLVD. Fire Sprinkler System revisions We have submitted drawings for plan review on this project. The construction schedule requires minor revisions pending permit issuance. Please issue a shut down number to allow us to perform this work starting Thursday, January 26, 2012. Response can be faxed to me at 206-763-5407. Please contact me at 206-832- 8454 with questions. We appreciate your assistance in this matter. David Roe Project Manager Fire Protection Division TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. 1a -s -0l. and exact address for shut- down hutdown or restoration approval. TOO/TOO'd 5005 Third Ave S., Seattle, WA 98134 Ph: (206) 762-3311 Fax: (206) 763-5407 '00 i AUSN I HOW 31:60 3103-93-NYI ©COPYRIGHT 2007-2014 BY REDHAWK FIRE & SECURITY SEATTLE: ALL RIGHTS RESERVED. Drawings RevO\FA.2.dwg 2 of w 0 PLOT DATE: 02—May-2016 DHS SEA CAP P2 4TH FL TI FIRE ALARM EXPANSION 12500 TUKWILA INT'L BLVD. SEATTLE, WA. 98168 SYMBOL LEGEND SYMBOL QTY DESCRIPTION MOUNi1NG REQUIREMENTS SUPPLIER PART NUMBER 8 1 CEILING SPEAKER w/ STROBE: WHITE 4 SQUARE DEEP w/ EXT RING; CENTER ON CEILING TILE NOTIFIER SPSCW V 1 PAIR 16AWG TWISTED \ SHIELDED FIRE RATED CABLE (FPLP) 609908 RED JACKET w/ YELLOW STRIPE SPEAKER (AUDIO) CIRCUIT 1" NOTES: 1- DEVICE SUBSCRIPT: NW=NEW RR=REMOVE & RELOCATE EX=DOSiiNG TO REMAIN AC=ABOVE CEILING RB=RELAY BASE WP=WATERPROOF WG=WIRE GUARD 2- CABI.EING SHOWN IS FOR CIRCUIT REFERENCE ONLY AND DOES NOT INTENDED TO INDICATE THE EXACT PATHWAY. 3- DEVICES SHOWN ON DRAWINGS IN GRAY SCALE ARE EXISTING DEVICES AND MAY NOT BE INCLUDED IN THIS SYMBOL LEGEND UNLESS NOTED. 4- SET HORN/STROBE DECIBLE SETTING TO LOW FROM FACTORY SETTING OF HIGH, ONLESS OTHERWISE NOTED ON THE DRAWINGS. 5- ALL DEVICES WITH A WP SUBSCRIPT WILL REQUIRE THE USE OF A OUTDOOR OR WP BACKBOX. WIRE LEGEND SYMBOL DESCRIPTION WEST PENN P/N COLOR CODING TYPE OF CIRCUIT APPLICATION NOTES S 2 COND. 14AWG THHN (IN EMT) 1 KENT, WA. 98032 (+) BLUE (-) GREY STROBE (NAC) CIRCUIT CONTACT: BRIAN SNYDER V 1 PAIR 16AWG TWISTED \ SHIELDED FIRE RATED CABLE (FPLP) 609908 RED JACKET w/ YELLOW STRIPE SPEAKER (AUDIO) CIRCUIT 1" NOTES: #* STRIPES ARE NOT REQUIRED, HOWEVER iT DOES MAKE IT EASIER FOR CIRCUIT IDENTIFICATION. 1- WIRE MANUFACTURER IS FOR REFERENCE PURPOSE ONLY. WHEN USING OTHER MANUFACTURE, ENSURE PROPER CROSS REFERENCE 2- FPLP CAN BE USED IN MOST ALL APPLICATIONS WITH THE EXCLUSION OF WET AND CIRCUIT INTEGRITY REQUIREMENTS 3- INSTALL WIRING PER NEC. USE CABLE TYPE CONSISTENT WITH NEC REQUIREMENTS, IE PLENUM, RISER, UNDERGROUND, ETC. 4- THE Y FIBER OPTiC CABLE LISTED IS A BELDEN CABLE PART NUMBER AS WEST PENN NO LONGER SUPPORTS FIBER OPTIC CABLE 5- THIS CABLE MUST BE INSTALLED IN A CONTINUOUS PATH POINT-TO-POINT. ABSOLUTLEY NO SPLICES ARE ALLOWED. 6- THIS CABLE IS A BELDEN SPECIFIC CABLE, NO ALTERNATES ARE ALLOWED APS9A Level 9 FCPS24-S8 (Aux Booster PS) Output Type »> Part 1: Description: Standby: Amps: Circuit Identifers: Output 11 NAC Sync 9-1 Output 12 NAC Sync S9-2 Output 13 NAC Sync S9-3 Output 14 NAC Sync S9-4 Total Qty SPSCW Ceifmg Speaker w/ Strobe set at 15cd 0.0000 0.0710 KENT, WA. 98032 5 CONTACT: BRIAN SNYDER 5 SPSCW Ceirmg Speoker w/ Strobe set at 30cd 0.0000 0.0960 3 1" BASE 10ADDRESS 3 SPSCW Ceiling Speaker w/ Strobe set at 75cd 0.0000 0.1530 FIRE ALARM I LIFE SAFETY PROVIDER: NAME: REDHAWK FIRE & SECURITY 0 SPSCW Ceiling Speaker w/ Strobe set at 95cd 0.0000 0.1760 BOTHELL, WA 98021 ONYX SERIES MAY HAVE PHONE: 425-486-2600 0 FAX: 425-486-2611 THE SAME FIELD ADDRESS SALESMAN: JOE SKVARLA joe.skvaria@redhawkus.com 0 scw Ceiling Strobe set at 15cd 0.0000 0.0710 EXT: 7607 1 luke.kooyman@redhawkus.com EXT: 7630 1 SCW Ceiling Strobe set at 30cd 0.0000 0.0960 LOOP NUMBER (SLC) 0 scv Ceiling Strobe set at 75cd 0.0000 0.1530 D D D 0 $cw Gerling Strobe set at 95cd 0.0000 0.1760 DEVICEA DRESS 1D127 O�O s 0 1D17 1® 2 \-- 1U.3 c �S J NFS-320 = 159 DET + 159 110D1 LOOP REMOVE TAB ON DALFIXI NFS2-640 = 159 DET + 159 MOD 2 LOOP 0 SP2C2415 Ceiling Speaker w/ Strobe set at 15cd 0.0000 0.0550 0 1 3 NOTIFICATION APPLIANCES: r, 0 t---) 14 SP2C2430 Ceiling Speaker w/ Strobe set at 30cd 0.00 0.0790 1 ? 4� 1 1 2 SP2C2475 Ceiling Speaker w/ Strobe set at 75cd 0.0000 0.1400 STROBE: L.F. SOUNDER: AUDIO ONLY: BELL DESINGATION: 2 7E2495 Ceiling Speaker w/ Strobe set at 95cd 0.0000 0.1730 6 = 6' BELL 8 = 8" BELL 10 =10"BELL 12 =12" BELL NOTE: A'WP ADJACENT TO THE DEVICE 1 NOTIFICATION I VISUAL CIRCUITS: 0 SC2415W Ceirmg Strobe set at 15cd 0.0000 0.0550 CIRCUIT TYPE: FLOOR THAT P.S, IS ON 0 SC2430W Ceiling Strobe set at 30cd 0.0000 0.0790 POWER SUPPLY 0 SC24791 Ceiling Strobe set at 75cd 0.0000 0.1400 ID 0 SC2495W Ceiling Strobe set at 95cd 0.0000 0.1730 1 2 "P" = 24VDC POWER CIRCUIT 3 "R' =i 24VDC RESET POWER CIRCUIT 0 Select A/V Device: SUB -CIRCUIT NUMBER .8.= STROBE CIRCUIT 0 Select A/V Device: "V"=VOICFJSPFAKERCIRCUIT� "Z" = ©O 0- 0 Select A/V Device: AUDIO RISER CIRCUIT FOR SYSTEM SENSOR HORNS: HORN DB ADJUST HORN DB SETTINGS /3 1 ' TEND) iTO /0' • ifltP3 LOW �r(,,l i (1) :;1 'Ill 0 Select A/V Device: 0 Select A/V Device: 1 0 1 Devices per Circuit Total Standby Circuit Calculated Arms (3): Total Akron Circuit Calculated iVePe (1): lyre Gauge Used (awg): Circuit Length (11): Estimated Voltage Drop (dc): Estimated EOL voltage (dc): 12 11 8 0 31 0.000 0.000 0.000 0.000 Ckt 1&2 1.711 0.769 0.942 0.903 0.000 14AWG 14AWG 14AWG Select Ckt 3&4 0.903 500 400 400 0 2.00 1.96 1.88 0.00 Total Amps 2.614 22.00 22.04 22.12 24.00 1) Current Draw Measurement bused on: 1A.1971, 16-33V, FM Input, High db & Temporal Patten 2) Outdoor/WP Devices have the same Measured Current Draw as the Indoor Devices and are not fisted separately above. 3) When the APS is configured for 'Doors', Output 14 shutsdown on loss of AC Power. Therefor no 'Standby' Current Draw is shown BATTERY LOAD CALC for APS9A: Backup Hours Required: Alarm Minutes Required: Acbral 8.OAH > > Total Amp Hours Required: Total Amp Minutes Required: Miniimun Battery Size Needed: Needed Inc udng a 30% Battery Depletion: Total AH Rated Batteries Supplied: =1 Total Standby Current = Total Nana Current = NAC POWER SUPPLIES CANNOT NEED or SELECT LARGER 0,0000 44 0.0 2.6140 15 0.7 EXCEED BATTERIES Battery Size 0.7 0.8 8.0 DEVICE DESIGNATION LEGEND: NOTIFIER ONYX SERIES ADDRESSABLE INITIATING DEVICES: CUSTOMER: NAME: HOLMES ELECTRIC ADDRESS: 600 WASHINGTON AVE S. BASE 1 ADDRESS KENT, WA. 98032 CONTACT: BRIAN SNYDER PHONE: 2534794000 FAX: NiA BASE 10ADDRESS EMAIL: brian.snyder@holmes.com FIRE ALARM I LIFE SAFETY PROVIDER: NAME: REDHAWK FIRE & SECURITY THE DETECTOR & MODULES ON BOTHELL, WA 98021 ONYX SERIES MAY HAVE PHONE: 425-486-2600 DETECTOR or MODULE FAX: 425-486-2611 THE SAME FIELD ADDRESS SALESMAN: JOE SKVARLA joe.skvaria@redhawkus.com EXT: 7616 PROJECT MANAGER: SLADE MILLER slade.miller@redhawkus.com EXT: 7607 DESIGNER: LUKE KOOYMAN luke.kooyman@redhawkus.com EXT: 7630 LOOP NUMBER (SLC) FOR EXAMPLE: D D D DEVICEA DRESS 1D127 O�O s 1D17 1® 2 \-- 1U.3 c �S J NFS-320 = 159 DET + 159 110D1 LOOP REMOVE TAB ON DALFIXI NFS2-640 = 159 DET + 159 MOD 2 LOOP ADDRESSES 100 AND ABOVE 02-3030 = 159 DET + 159 MOD (0 LOOP NOTIFICATION APPLIANCES: r, 0 t---) ? 0 ? ? 4� 1 1 1--- STROBE: L.F. SOUNDER: AUDIO ONLY: BELL DESINGATION: 5 =15cd 9= 95cd 50=1500:1 L3 =135cd 3=30cd 0=110x1 77=177cd L5 =150cd 6 =60cd 15= 115cd 85=185cd L7 =177cd 7=75cd 35 =135cd L8 =185cd M =MINI HORN H=HORN ONLY F=SPEAKER ONLY LF=LOW FREQUENCY 6 = 6' BELL 8 = 8" BELL 10 =10"BELL 12 =12" BELL NOTE: A'WP ADJACENT TO THE DEVICE INDICATES THAT THE DEVICE IS OUTDOOR RATED NOTIFICATION I VISUAL CIRCUITS: CIRCUIT TYPE: FLOOR THAT P.S, IS ON "C' = FACP NAC CIRCUIT POWER SUPPLY "N"=APS NAC CIRCUIT ID "P" = 24VDC POWER CIRCUIT "R' =i 24VDC RESET POWER CIRCUIT SUB -CIRCUIT NUMBER .8.= STROBE CIRCUIT "V"=VOICFJSPFAKERCIRCUIT� "Z" = ©O 0- N1A•2 COMPLETE CIRCUIT# AUDIO RISER CIRCUIT FOR SYSTEM SENSOR HORNS: HORN DB ADJUST HORN DB SETTINGS /3 1 ' TEND) iTO /0' • ifltP3 LOW �r(,,l i (1) :;1 'Ill SETTINGS: FOR WHEELOCK HORNS: ADJUST HORN DB SETTINGS l 11 <r f I 1 i l l SYMBOL & WIRE STYLE IDENTIFICATION J -BOX � 2C,0 s WIREICABLE INDENTIFIER 2C .22 lYPE "C' CABLES D =1 TYPE 'D' CABLE OPEN CABLE' S RACEWAY S CABLE INSTALLATION TYPES s- -0- -<3 - -0-- • S DEMO OR REMOVE EQUIPMENT FROM SERVICE RACEWAY REQUIRED TO BE INSTALLED UTILIZING 1 of 3 NEC APPROVED 2HR METHODS OF PROTECTION S- - • • .I}I • • - • -6 AC POWER (120, 240 or 480VAC) S--2HR----2HR-�j X xx END of LINE RESISTOR FLAG NOTE 1- -ENLARGED VIEW BOUNDRY -•-i- TOP LINE INDICATES THE DETAIL # - J BOTTOM LINE INDICATES THE SHEET # _ J� ELEVATION DETAIL SHEET NOTE ADA ROOM, AREA OR - ZONE BOUNDRIES - 2HR RATED WALL PARTIAL HEIGHT WALL 1 HR RATED WALL 10'-0° ATC CEILING INFO EQUIPMENT NOTE FULL HEIGHT WALL FIRE ALARM GENERAL NOTES: 1. INSTALLATION SHALL BE ACCOMPLISHED IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE AHJ's, NEC AND CONTRACT DRAWINGS 2. WIRE ROUTING IS DIAGRAMMATIC IN NATURE ONLY AND NOT INTENDED FOR ACTUAL CONDUIT ROUTING. 3. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ. 4. THE SYSTEM SHALL BE MONITORED BY A U.L. LISTED MONITORING STATION BEFORE AHJ TEST. 5. VERIFY All LOCATIONS OF DEVICES WITH ELECTRICAL/ARCHITECTURAL PLANS. SCALE AND PLACE ALL DEVICE PER ELECTRICAL/ARCHITECTURAL PLANS. 6. FIELD VERIFY WATERFLOW, SMOKE DAMPERS AND DUCT DETECTORS LOCATIONS. 7. FIELD VERIFY ALL WIRING LOCATIONS AND REQUIREMENTS FOR HVAC AND FAN CONTROL 8. SMOKE DETECTORS SHALL NOT BE LOCATED WITHIN 36° OF ANY AIR DIFFUSER. 9. NFPA72 (2002) 5.7.1.11 REQUIRES THAT NO DETECTORS SHALL BE INSTALLED UNTIL AFTER FINAL CONSTRUCTION CLEAN-UP. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO CLEAN-UP MUST BE CLEANED OR REPLACED AND WILL BE INVOICED ON A T&M BASIS. 10. FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF REDHAWK FIRE & SECURITY TECHNICIANS. 11. ALL CIRCUITS WILL BE PROPERLY TAGGED AND TESTED FOR OPENS, SHORTS, GROUNDS AND PROPER "END -OF -LINE" RESISTANCE. EACH CIRCUITS METER READING MUST BE DOCUMENTED AND PRESENTED TO REDHAWK FIRE & SECURITY FIELD TECHNICIAN UPON ARRNAL ONSITE FOR STARTUP & CHECKOUT. 12. A SET OF INSTALLATION AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY REDHAWK FIRE & SECURITY TECHNICIAN. 13. AGREEMENT AND CONFIRMATION OF ALL MILESTONE EVENTS WILL BE MADE WiTH REDHAWK FIRE & SECURITY PROJECT MANAGER. ALL REDHAWK FIRE & SECURITY FIELD SERVICES MUST BE SCHEDULED WITH REDHAWK FIRE & SECURITY PROJECT MANAGER WF H A MINIMUM OF 10 WORKING DAYS ADVANCE NOTICE. 14. NO TAPPING OF SIGNALING OR INMATiNG ZONE CIRCUITS ARE ALLOWED. T -TAPPING OF STYLE 4 ADDRESSABLE CIRCUITS IS ALLOWED PROVIDING A SPLICE IS PROFESSIONALLY INSTALLED, POLARITY IS OBSERVED AND SHIELDS ARE CONTINUOUS AND FREE OF GROUNDS. SHIELDS MUST BE TERMINATED AT FACP ONLY. CABLE SHIELDS SHALL BE SPLICED TOGETHER AT EVERY JUNCTION BETWEEN THE FACP AND THE LAST DEVICE ON EACH CABLE RUN. SHIELDS AND OTHER FIRE ALARM CONDUCTORS (EXCEPT POWER GROUNDS) SHALL BE INSULATED AND COMPLETELY FREE FROM CONDUIT OR EARTH GROUNDS. SHIELDS WILL BE TIES TO GROUND ONLY AT THE FACP BY THE REDHAWK FIRE & SECURITY FIELD TECHNICIAN. 15. MOUNT AUDIBLE/VISUAL DEVICE BACKBOX BETWEEN A MINIMUM OF 80° AFF TO A MAXIMUM OF 96" AFF. SEE FLOOR PLANS FOR CANDELA RATING OF EACH DEVICE INSTALLED. 16. AS-BUILTS ARE REQUIRED AT TIME OF AHJ ACCEPTANCE. REDHAWK FIRE & SECURITY REQUIRED ELECTRICAL RED LINES WITHIN 2 WEEKS PRIOR TO AHJ TESTS. 16.1. EACH CIRCUIT (SLC, NAC OR POWER) MUST BE CLEARLY IDENTIFIED WITH A DISTINCT COLOR 16.2. EACH NAC CIRCUIT MUST BE CLEARLY MARKED AS TO WHICH DEVICES ARE ON EACH CIRCUIT AND IN THE ORDER THE DEVICES ARE WIRED TO COMPLETE THE CIRCUIT. 17. NO UNE VOLTAGE IN SAME CONDUIT AS POWER LIMITED FIRE ALARM CABLE. 18. ALL MANUAL PULL STATIONS ARE TO BE MOUNTED AT A HEIGHT NO GREATER THAN 48' TO TOP AND NO LOWER THAN 36° TO BOTTOM. PROJECT CONTACT INFORMATION: CUSTOMER: NAME: HOLMES ELECTRIC ADDRESS: 600 WASHINGTON AVE S. KENT, WA. 98032 CONTACT: BRIAN SNYDER PHONE: 2534794000 FAX: NiA EMAIL: brian.snyder@holmes.com FIRE ALARM I LIFE SAFETY PROVIDER: NAME: REDHAWK FIRE & SECURITY ADDRESS: 21312 30TH DRIVE SE, SUITE #103 BOTHELL, WA 98021 PHONE: 425-486-2600 FAX: 425-486-2611 SALESMAN: JOE SKVARLA joe.skvaria@redhawkus.com EXT: 7616 PROJECT MANAGER: SLADE MILLER slade.miller@redhawkus.com EXT: 7607 DESIGNER: LUKE KOOYMAN luke.kooyman@redhawkus.com EXT: 7630 SHEET SCHEDULE: SHEET i1 DESCRIPTION FA.0.0 GENERAL NOTES & INFO FA2.0 WIRING DETAILS Without Comments As Noc eo in Re& Per (, `:, :ACtache0 Letter These plans have i:,k ,a. c -,.viewed by The Tukwila Fire r -i c enntion Bureau v' ,ti current City ;ons which t :lards rain: fii3' des4 i , . • din ons, Oeiettk.',s Jp ec't 5o rors and orr _G violations of adopted e responsibility; for the with the designer. mesa: drawings after oatwi \ O c and will require a i >>�:i:m�tta .:; •,- •3ubsequent approval. Fv-kal; acceptance and Inspection by He Tukwila I krb = .. O: .it reau. Dace: - 9 -.lc, FERE. t., D PARTT ENT 205-5754407 and Iva this Fire Permit No -093 r. -ria z,y Gct addmss for shut- down or it on r,pprovat. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must he presented to the Inspector prior to commencement of Acceptance Testing Of 3t y Fire Alarm and C- ':e(ti0n S;'stms. Failure o:: in a fie -i sc.)e l.i . i'-. ,, and to rniir1iit c t i .., li ort PAI Itt ( -2 2011 TUKWILA FIRE ,Z-2,6"-13‘) )-200- WHEN PRINTED ON ARCH -0 (24x36) 0 WAIN idigg i SCALE: DEVELOPMENT RELEASE DATE: 04129/2016 GENERAL NOTES AND INFORMATION FAUOIO LJ C••••1 SCOPE OF WORK 10 ADD NEW DEVICE IN NEV OMCE 6046 D -c S9-2 V1-13 S,21, 23,2V (1\ 2S,2V V1-13 V1-13 3080 [Ls] S,2V S9-2 V1-13 1,111VA W.A64 uiiamiiuui S5 -4'i V1-8 3087 [1.) 3086 R inu 302 :)6v,2i.i,:i.....':,,,,,,.?.r., Fr.:..1.i,.)...7 jiLl D Tl (Li S,V C )-2S S5-4 V1-8 6057 0,P , S 3018 3067 3076 riR 3100 RF1 V 3026 D- D 2A S,V S9-1 V1 -13n 313E , V1-13 1 tvil I I " P V I n 084 9-1 1-13 2A 3091 1-1 )-S,V R 3109 TO OOF 3 0 S9-3 V1-13 6022 0 [D 3070 fl" S5-4 V1-8 HR N5-4 6031 S5-3 V1-8 NIC. 11111 MI I -11M1 NNW 1111111•11111M111111111111 1.11121•11/4111111111111111111111 lamfram 11111EraMmun1111111111N1111 '":4111111111111111110111111111111 _QM IMMO 6002 SCALE: = 1'-0" 8 6 4 2 0 WHEN PRINT D ON ARCH -D (24x36) 2 gitg421142 w a a . geldiOgm ig *9 RP -632N SCALE: iv. fr DEVELOPMENT RELEASE DATE: 04t32016 CC LU "ae cm* FAS LAYOUT 4TH FLOOR TI FA.2.0 21312 30TH DRIVE SE, BOTHELL, WA. 98021 P:425-488-2600 F425-486-2611 WA LICENSE #: REDHAHF882NH WA UBI: 602685-851 i 12500 TUKWILA INTI BLVD. SEATTLE, WA. 98168 FIRE ALARM EXPANSION 1 mit I M 1 g a ..< a 111w NIHH SCALE: iv. fr DEVELOPMENT RELEASE DATE: 04t32016 CC LU "ae cm* FAS LAYOUT 4TH FLOOR TI FA.2.0 3 8 PLOT DATE: 19—Feb-2015 SYMBOL LEGEND SYMBOL QTY DESCRIPTION MOUNi1NG REQUIREMENTS SUPPLIER PART NUMBER D 3 INTEUJGENT PHOTO SMOKE DETECTOR 4 SQUARE DEEP w/ 3' ROUND RINGEd NOTIFIER FSP -851 S 2 NW COLING SPEAKER w/ STROBE WHiTE 4 SQUARE DEEP; CENTER ON CEILING 11LE NOTIFIER SPSCW V 1 PAIR 16AWG TWISTED \ SHIELDED FIRE RATED CABLE (FPLP) 609908 RED JACKET w/ YELLOW STRIPE SPEAKER (AUDIO) CIRCUIT v NOTES: 1- DEVICE SUBSCRIPT: NW=NEW RR=REMOVE & RELOCATE EX=EXISTING TO REMAIN 2- DEVICES SHOWN FOR IDENTIFICATION ONLY 3- DEVICES SHOWN ON DRAWINGS IN GRAY SCALE ARE EXISTING DEVICES AND MAY NOT BE INCLUDED IN THE ABOVE SYMBOL LEGEND 4- SET HORN/STROBE DECIBIE SETTING TO LOW FROM FACTOR( SETTING OF HIGH, ONUS OTHERWISE NOTED ON THE DRAWINGS. 5- THIS RICER REQUIRES THE USE OF A WP BACKBOX. WIRE LEGEND SYMBOL DESCRIPTION WEST PENN P/N COLOR CODING TYPE OF CIRCUIT APPLICATION NOTES D 1 PAIR 16AWG TWISTED \ NON SHIELDED FIRE RATED CABLE (FPLP) 60991B RED JACKET w/ NO STRIPE DATA (SLC) CIRCUIT 1 J S 1 PAR 14AWG ARE RATED CARIE (FPLP) 609938 RED JACKET w/ WHITE STRIPE STROBE (NAC) CIRCUIT FAX: 253-234.2914 V 1 PAIR 16AWG TWISTED \ SHIELDED FIRE RATED CABLE (FPLP) 609908 RED JACKET w/ YELLOW STRIPE SPEAKER (AUDIO) CIRCUIT v NOTES: # STRIPES ARE NOT REQUIRED, HOWEVER IT DOES MAKE T EASIER FOR CIRCUIT IDENTIFICATION. 1- WIRE MANUFACTURER IS FOR REFERENCE PURPOSE ONLY. WHEN USING OTHER MANUFACTURE, ENSURE PROPER CROSS REFERENCE 2- FPLP CAN BE USED IN MOST ALL APPLICATION WiTH THE EXCLUSION OF WET AND CIRCUIT INTEGRITY REQUIREMENTS 3- INSTALL WIRING PER NEC. USE CABLE TYPE CONSISTENT WITH NEC REQUIREMENTS, NTS, IE PLENUM, RISER, UNDERGROUND, ETC. 4- THEY FIBER OPTIC CABLE LISTED IS A BELDEN CABLE PART NUMBER AS WEFT PENN NO LONGER SUPPORTS FIBER OPTIC CABLE 5- THIS CABLE MUST BE INSTATED IN A CONTINUOUS PATH POINT -TO -PONT. ABSOLUTR NO SPLICES ARE AMID. 6- THIS CABLE IS A BELR SPECIFIC CABLE, NO ALTERNATES ARE ALLOWED FLAGNOTES NOTE 1 I DESCRIPTION 34 ,DEVICE ADDRESS ASSIGNED BY RED HAWK F&S AILD TECHNICIAN ONCE ON-SITE MEd Entire Blaring M-120 Circuit Identifier: Control Output » Watts: PKG 3 FCM-1 V1-1 PKG2 V1-2 PKG1 FCL, -1 V1-3 GM EL FCM-1 V1-4 FIR 1 FCM-1 V1-5 FIR F11-1 V1-6 FTR3 FCM-1 V1-7 RR V1-8 aEVS FCM-1 V1-9 Vi -10 FIR 3 CORE TCL, -1 V1-12 Tata) Qty 1/8 1/4 1/2 1 2 4 8 0.0052 0.0104 0.0208 0.0416 0.0832 0.1664 0.3328 24 5 115 0 0 0 0 Speakers set at 25 volt # De►4ces per Ckaa'tr Tata watts per Mc* Totd Nnps Cdadaied per Circa (1 P / V): Vire Gauge Used(awg): Gra& Length (ft): Estimated Vdtoge Drop (dc): Fetkrmted EOL Voltage (dc): 0 0 0.000 14AWG 0.00 0 0.000 0.000 14P .0 0.00 24 6.000 0250 14G 120 100 1.04 24.00 24.00 22.96 Totd watts 29.375 Level 8 FCPS24-S8 (ha Booster PS) Pot j: Output Type »> Ampt Crani Menace: Outputf1 OutpAf2 Oubstf3 QIP} NAC Sync NAC Sync NAC Sytt NAC Sync S8-1 S8-2 S8-3 S8-4 Total Qty SPSCW GATmg Speaker w/ Strobe set at 15cd 0.0000 0.0710 7 1 SPSCW Ceing Speder w/ Strobe set at 30x1 0.0000 0.0960 2 2 SPSCW Ging Speaker w/ Strobe set at 75cd 0.0000 0.1530 2 2 SPSOI Speaker w/ Strobe set at 95cd 0.0000 0.1760 0 0 sew Cetng Strobe set at 15cd 0.0000 0.0710 0 sot Ging Strobe set at 30c4 0.0000 0.0960 0 XIV GIN Strobe set at 75cd 0.0000 0.1530 0 sew Ceiig Strobe set at 95cd 0.0000 0.1760 0 0 SP2C2415 Ceeng Speaker w/ Strobe set at 15cd 0.0000 0.0550 8 SP2C2430 Csig Speaker w/ Strobe set at 30cd 0.0000 0.0790 3 SP2C2475 Ceing Speaker w/ Strobe ort at 75cd 0.0000 0.1400 SP2C2495 Ceig Speer w/ Strobe set at 95cd 0.0000 0.1730 0 0 Sc2415 Cei q Strobe set at 15cd 0.0000 0.0550 SC2430. Ceing Strobe set at 30cd 0.0000 0.0790 0 SC2475W Coley Strobe set at 75cd 0.0000 0.1400 0 SC2495w Cei irg Strobe set at 95cd 0.0000 0.1733 0 0 0 0 0 0 0 # Devices per Meet Total Stondb r Crani Cdaiated Amps (3): Total Alarm Crani Calculated Mips (1): Iftre Gauge Used (meg): Grcuit Length (ft): Estimated Voltage Drop (dc): Estimated EOL Voltoge (dc): 11 0 0 24 0.000 0.000 0.000 0.995 0.000 0.000 Cut 1d2 L867 14AVZ 400 CA 3&4 0.000 2.07 0.00 0.00 21.93 24.00 24.00 Total Mie 1.867 1) Current Grow Measurement based on: UL1971, 16-331►, RR lout, I1 db k Temporal Patten 2) Outdoor/WP Devices have the same Measured Current Draw as the kndoor Devices and are not fisted separotely above. 3) When the APS is canragtred for'Doors', Output 14 shutsdown on loss of AC Power. Therein no 'Stand)? Current Draw is shorn BATTERY LOAD CALC for APS8A: Total Sta nd1 Current: = Tata Nom Current = 0.0000 1.8610 NAC POWER SUPPUES CANNOT EXCEED 8.0AH NEED or SELECT LARGER BATTEEIES > > Bhp Hors Required: Norm lodes Requited: 24 15 Total Amp tours Required: Total Amp Volutes Required: Mrrk un Battery Size Needed: Akdud Battery Sae Needed IncluSmg a 30% Battery Depletion: 0.0 0.5 0.5 0.6 Total AH Rated Batteries SuppFied: =1 8.0 DEVICE DESIGNATION LEGEND: NOTIFIER ONYX SERIES ADDRESSABLE INITIATING DEVICES: CUSTOMER: NAME: HOLMES ELECTRIC oil rm DEVICE PANEL SIGNAL 6 1 J ADDRESS LOOP CIRCUIT (SLC) FAX: 253-234.2914 F HOMELAN] NATIONAL BLVD. SEAT'] &RM EXPANSIC EMAIL: ric.furgurgur@holmes.com v I"xx7"I PLUS ADDRESS: 21312 30TH DRIVE SE, SUITE #103 "127" EQUALS ® 0 0 0 0 7 8 08 PHONE: 425-486-2600 "D" = DETECTOR "M" 5 ° 9 101 5 B g ,�,� SALESMAN: JOE SKVARLA = MODULE NOTE A DETECTOR & MODULE MAY HAVE THE SAME FIELD ADDRESS EXT: 7616 a 2 TENS " 4s ��%13 2 1 0 15 14 ONES �` 1 0 DESIGNER: LUKE KOOYMAN EXAMPLE: D D D 6g, b v�s IFS -320 = 159 DET + 1591400 (1 LOOP) s 'ili2' REMOVETABONDPIFOR ADDRESSESIODANDAaOVE 7152-640 = 1591ST + 159 MOD (2 LOOP) NTS2-3030 = 159 DET + 159 1400 (0 LOOP) NOTIFICATION I VISUAL CIRCUITS: CIRCUIT TYPE: POWER SUPPLY "C" = FACP NAC CIRCUIT OR AMP NUMBER "N" = APS MAC CIRCUIT "P" = 24VDC POWER CIRCUIT "R" = 24VDC RESET POWER CIRCUIT SUB -CIRCUIT NUMBER "S" = STROBE CIRCUIT II) 0 © CE "Z'=AUDORISER CRCUTUIT - N1A-2 RCUT#NAC NOTIFICATION APPLIANCES:,SJ, NT�.OBECANDELA .%" - 30cd "6"=60cd BELL SIZE DESIGNATIONnv '6' = 6° BELL T = 75cd '9' - Mad '8'= 8' BELL i "0" =110cd '15'= '10'=10" BELL r ? 115a1 •35•=1 '7 -12' BELL 50" -150cd NOTE: A "W' WITHIN THE DEVICE 77'=177cd '85"=1854d 'H' = HORN ONLY OR A INP' ADJACENT TO THE DEVICE 'S' = SPEAKER ONLY INDICATES THAT THIS DEVICE IS WEATHERPROOF SYSTEM SENSOR ADJUST HORN DB SETTINGS HORN DB SETTINGS: ADJUST HORN DBSETTINGS s 6 '1' = TEMP3 HI 3 "2' = TEMP3 MED I I 1 9� ( �4 2I ` ' m "3' =TEMPS LOW 4" = CONE HI '5' = CONT MED gig l g "6"=CONT LOW NNSS FIRE ALARM GENERAL NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 16.1. 16.2. 17. 18. INSTALLATION SHALL BE ACCOMPUSHED IN STRICT COMPLIANCE WiTH NFPA, LOCAL AND STATE AHD's, NEC AND CONTRACT DRAWINGS WIRE ROUTING IS DIAGRAMMATIC IN NATURE ONLY AND NOT INTENDED FOR ACTUAL CONDUIT ROUTING. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ. THE SYSTEM SHALL BE MONITORED BY A U.L LISTED MONITORING STATION BEFORE AHJ TEST. VERIFY ALL LOCATIONS OF DEVICES MTH ELECTRICAL/ARCHiTECTURAL PLANS. SCALE AND PLACE ALL DEVICE PER ELECTRICAL/ARCHITECTURAL PLANS. FIELD VERIFY WATERFLOW, SMOKE DAMPERS AND DUCT DETECTORS LOCATIONS. FIELD VERIFY ALL WIRING LOCATIONS AND REQUIREMENTS FOR HVAC AND FAN CONTROL SMOKE DETECTORS SHALL NOT BE LOCATED WITHIN 36' OF ANY AIR DIFFUSER. NFPA72 (2002) 5.7.1.11 REQUIRES THAT NO DETECTORS SHALL BE INSTALLED UNTIL AFTER FINAL CONSTRUCTION CLEAN-UP. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO CLEAN-UP MUST BE CLEANED OR REPLACED AND WILL BE INVOICED ON A T&M BASiS. FRCP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF REDHAWK FIRE & SECURITY TECHNICIANS. ALL CIRCUITS WILL BE PROPERLY TAGGED AND TESTED FOR OPENS, SHORTS, GROUNDS AND PROPER 'END -OF -UNE' RESISTANCE. EACH CIRCUITS METER READING MUST BE DOCUMENTED AND PRESENTED TO REDHAWK FIRE & SECURITY FIELD TECHNICIAN UPON ARRNAL ONSITE FOR STARTUP & CHECKOUT. A SET OF INSTALLATION AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR ROUTES SIRE BE KEPT BY PROJECT FOREMAN FOR USE BY REDHAWK FIRE & SECURITY TECHNICIAN. AGREEMENT AND CONFIRMATION OF ALL MILESTONE EVENTS WILL BE MADE WiTH REDHAWK FIRE & SECURITY PROJECT MANAGER. All REDHAWK FIRE & SECURITY FIELD SERVICES MUST BE SCHEDULED WITH REDHAWK FIRE & SECURITY PROJECT MANAGER WITH A MINIMUM OF 10 WORKING DAYS ADVANCE NOTICE NO TAPPING OF SIGNAUNG OR INITIATING ZONE CIRCUITS ARE ALLOWED. T -TAPPING OF STYLE 4 ADDRESSABLE CIRCUITS IS ALLOWED PROVIDING A SPLICE IS PROFESSIONALLY INSTALLED, POLARITY IS OBSERVED AND SHIELDS ARE CONTINUOUS AND FREE OF GROUNDS. SHIELDS MUST BE TERMINATED AT FACP ONLY. CABLE SHIELDS SHALL BE SPLICED TOGETHER AT EVERY JUNCTION BETWEEN THE FACP AND THE LAST RICE ON EACH CABLE RUN. SHIELDS AND OTHER FIRE ALARM CONDUCTORS (EXCEPT POWER GROUNDS) SHALL BE INSULATED AND COMPLETELY FREE FROM CONDUIT OR EARTH GROUNDS. SHIELDS WiLL BE TiES TO GROUND ONLY AT THE FACP BY THE REDHAWK FIRE & SECURITY FIELD TECHNICIAN. MOUNT AUDIBLE/VISUAL RICE BACKBOX BETWEEN A MINIMUM OF 80' AFF TO A MAXIMUM OF 96' AFF. SEE FLOOR PLANS FOR CANDELA RATING OF EACH DEVICE INSTALLED. AS-BUiLTS ARE REQUIRED AT TIME OF AHJ ACCEPTANCE. REDHAWK FIRE & SECURITY REQUIRED ELECTRICAL RED UNES WITHIN 2 WEEKS PRIOR TO AHJ ILSI5. EACH CIRCUIT (SLC, NAC OR POWER) MUST BE CLEARLY IDENTIFIED WITH A DISTINCT COLOR EACH NAC CIRCUIT MUST BE CLEARLY MARKED AS TO WHiCH DEVICES ARE ON EACH CIRCUIT AND iN THE ORDER THE DEVICES ARE WIRED TO COMPLETE THE CIRCUIT. NO UNE VOLTAGE IN SAME CONDUIT AS POWER LIMITED ARE ALARM CABLE. ALL MANUAL PULL STATIONS ARE TO BE MOUNTED AT A HEIGHT NO GREATER THAN 48' TO TOP AND NO LOWER THAN 36' TO BOTTOM. EXiEND DATA FROM EXISiING SAXE DETECTOR IN CORRIDOR TO NEWSMOKE DETECTORS IN OFFICES 1-3. INTERRUPT V1-12 NO S8-2 VOICE AND STRODE CIRCUITS AT SPEAKER/STROBE IN CORRIDOR EXTEND TO NEW SPEIUOR/STROBES Q WU 1 AND 3, THEN CONiINUE WIRE ON TO EXISTING SPEAKER STROBE IN CONFERENCE RLI. SYMBOL & WIRE STYLE IDENTIFICATION J -BOX T 2C,D 6 s T OPEN CABLE RACEWAY WIREICABLE INDENTIFIER 2C = 2 TYPE "C" CABLES D =1 TYPE "D" CABLE CABLE INSTALLATION TYPES 5- --E;- -S DEMO OR REMOVE EQUIPMENT FROM SERVICE RACEWAY REQUIRED TO BE INSTALLED UTILIZING 1 of 3 NEC APPROVED 2HR METHODS OF PROTECTION 5- - • • •f }{ • • - -5 AC POWER (120, 240 or 480VAC) S-- 2HR X xx ENLARGED VIEWPORT BOUNDRIES TOP LINE INDICATES THE DETAIL # BOTTOM LINE INDICATES THE SHEET # 10'-0' ATC CEILING INFO SHEET NOTE WIRING DETAIL INTERIOR ELEVATION i ply AIR FLOW DIRECTION MI a - - e I ADA ROOM, AREA OR ZONE BOUNDRIES I FULL HEIGHT WALL /////////// PARTIAL HEIGHT WALL ■ 2HR RATED WALL 1 HR RATED WALL PROJECT CONTACT INFORMATION: glyiiiipi 1 CUSTOMER: NAME: HOLMES ELECTRIC oil ADDRESS: 600 WASHINGTON AVENUE SOUTH KENT, WA. 98032 6 CONTACT: RIC FEGURGUR PHONE: 253-234-2835 FAX: 253-234.2914 F HOMELAN] NATIONAL BLVD. SEAT'] &RM EXPANSIC EMAIL: ric.furgurgur@holmes.com FIRE ALARM I LIFE SAFETY PROVIDER: NAME: REDHAWK FIRE & SECURITY ADDRESS: 21312 30TH DRIVE SE, SUITE #103 BOTHELL, WA 98021 PHONE: 425-486-2600 FAX: 425-486-2611 SALESMAN: JOE SKVARLA joe.skavaria@redhawkus.com EXT: 7616 PROJECT MANAGER: JEREMY MUNSON jeremy.munson EXT: 7604 DESIGNER: LUKE KOOYMAN Iuke.kooyman@redhawkus.com EXT: 7630 NOT IN SCOPE: CONFERENCE J)FASLAYOUT SCALE::1/8"4 Comments 0, 0 Pik, il'4 ',`,:e plans havebeen .o_. iukwila Fre 7"4"entlon Bureau for. c , 11:.1r1.na ct.,: , ii current City ::card,, cc:: c ' ce ro •:::.!frors and (`r-v7}(c of adopted •7 Vii:. tri ••..:o1ri'.'ry!iIC, for the y1�aC1of design rests Tutu ,; rVII) 1l e ;designer. Additions, deletions or revisions to drawings after this date will void this acceptance and will require a resubmittal of revised drawings Tor: approval. Final acceptance Is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: -(5 By:C J I C NOTTCF ' completed, mit. ?^ Tukwila Fire Department Pi-,.- est Cer k ific mi.'s iu sir eEen .ed to prior to con?nI nce, 1e.1t: or Acceptance Testing ng os ;Any Fire A,1arm and c: a7.ction Systems. Fail Li tcst3, will result F�r,i.e3 .. of 1.1.;..,1- result i1n a Re -inspection Fee and termination of the testing TUKWILA FIRE D7.,rnRTINENT (':k .DSS €:rA 206-575-4407 and cjive��lJorm t 'tis Fire Permit s s F:ind exact shut- down or T•ea o4 r lions appr.:Nal. PAID FEB 2 WM/VVILA F y.5-0 16 //ov 2 °' 1.121r4MM w id Hip glyiiiipi 1 NIIII oil 0 W s 6 SCALE t" =1'-0" 8 6 4 2 0 WHEN PRINTED ON ARCH -D (24x36) D HAWK >ecu DRIVE SErity, BOTHELL, WA. 98021 2600 F:425-486-2611 E # REDHAHF882NH 2685-851 ubb DETECTONJOG,C FIRE PROTECTION F HOMELAN] NATIONAL BLVD. SEAT'] &RM EXPANSIC 11 wiLl Lgki SCALE: 118" =1%0" DEVELOPMENT RELEASE DATE: 0211912015 FAS LAYOUT DHS INA 3RD FLOOR 11 FA -100 SH T 3ESC TIO\ DHS OFFICE T.I. FIRE ALARM SYSTEM ADDITION FA -01 FRE ALA 1\/ SLA\ SHEET LIST QUANTITY EX EX 2 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER• EX POWER SUPPLY (EXISTING) SK -5495 SILENT KNIGHT PROVIDED VERIFY IN FIELD FIRE ALARM HORN STROBE 15 EX (EXISTING) PC2R SYSTEM SENSOR 4S BOX CEILING FIRE ALARM STROBE SCR SYSTEM SENSOR 4S BOX CEILING EOL END OF LINE RESISTOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N /A U.O.N. UNLESS OTHERWISE NOTED N/A N/A N/A N /A VL VERIFY LOCATION IN FIELD N/A N/A N/A N/A WP WEATHERPROOF DEVICE N /A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A TUKWILA, WASHINGTON TO OTHER EXISTING DEVICE TO OTHER EXISTING DEVICE PARTIAL FIRST FLOOR FIRE ALARM PLAN SCALE: 3/16" = 1'0" 4A R tn,-^t r 6,4 y i e . . .uU Il dit4a i m{cW.,cw 1.!:7 ,;use of ire,:;e.umd demand , r rand ot;,r l:iap ' tors' s'the'duk;? arc. booked .a_F days ahead. The! efbre,YOU. +Hid need:to call 206-5154407 t;. sch •:dule your inspections a minimum of 48 hours in advance of the date you want an insp action. .FILE SYMBOLS LEGEND WIRE SCHEDUL AND CO \ D U IT FILL CHAT WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE S STROBE CIRCUIT TWO #14 FPLP CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WWW*WXWWWWWWWWXNEWXXWNE*WW*WW****WW**XWXWWXXXXW*WWWWWX**WNEW WWW BATTERY SIZING CALCULATI❑N XXXXWWW WWXWWX*WWWW***00 **XXXWXWWXWW*XXXX*XX*XWNEXX Job Name: DHS OFFICE Panel Location: EXISTING POWER SUPPLY BATTERY CALCS Date Performed: 10-08-2012 QTY• DEVICE NAME STD-BY(Amps) ALARM(Amps) 1 PS: SK -5495 12 H/S: P2W-15 6 H/S: P2W-30 3 H/S: P2W-75 6 H/S: PC2R-15C 11 STR: SCR -:50 2 STR: SCR -30C 7 STR: SCW-:5 4 STR: SCW-30 0. 0750 0. 0000 0. 0000 0. 0000 0. 0000 0. 0000 0. 0000 0. 0000 0. 0000 0. 1750 0. 9480 0. 6420 0, 5280 0. 8100 0. 8690 0. 2140 0. 4620 0. 3760 Totals = 0. 0750 5. 0240 Stand -By Load = 0,0750 Amps Stand -By Time = 24 Hrs. Stand -By = 1.80 Amp)Hrs Total = Stand -By + Alarm = ? . 80 + 0.42 = 2. 22 Amp*Hrs Alarm Load = 5.0240 Amps Alarm Time = 5/60 Hrs. Multiply by De -Rating Factor of 1.25 Alarm = 0.42 Amp?Hrs ---> 2. 22 1. 25 = 2. 77 * MINIMUM BATTERY SIZE = 2,77 Ampere*Hours ** RECOMMENDED MINIMUM BATTERY SIZE = USE 12VDC 18AH BATTERY SIZE ** XXXXXXXXXXXXXXWXWWWWXXXXXXXXXXXXXXXXXXN0001010101(WWWXWXWXXXXWWWNENOf WORST CASE VOLTAGE DROP CALCULATI❑N wwwxwxxxxxxxxxxxxxwwwwwwwwwwwxxxxwwwwxxxxxxxxwwwwwwwwwwxwwwwww Job Name: DHS OFFICE Circuit: SIGNALING CIRCUIT VOLTAGE DROP CALCS Date Performed: 10-08-2012 3 H/S: P2W-15 4 H/S: P2W-30 3 H/S: PC2R-15C 4 STR: SCR -15C Circuit Length = Circuit Load = Voltage Drop = Voltage Drop = Voltage Drop = at at at at 0. 0790 Amps 0. 1070 Amps 0. 1350 Amps 0. 0790 Amps 245 Ft to End 1. 3860 Amps (Ckt. Load) * (Ckt, each each each each = 0. 2370 Amps = 0,4280 Amps 0,4050 Amps = 0. 3160 Amps Total = 1. 3860 Amps Wire Size = #14 AWG Voltage = 24.0 Volts Length) * 21. 6 (Circular Mils) * (Volts) ( 1. 3860 ) * ( 245 ) * 21. 6 ( 4110 ) * ( 24, 0) 7.44% * 100% 100% AC , Without Comments p As Noted in Red 0 Pei' The Attached Letter These plans have been reviewed by The Tukyvila Fire r a•evention Bureau for conformance with current City -:nuiards. Acceptance is subject to errors and c:rnissions which do not authorize vioiations of adopted z:andards and ordinances. The respons biiity for the t�dequacy of design rests tota .-,--,vith the des finer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a • resubmittal of revised drawings for subsequent approval, Final acceptance is subject to field test and Inspection bl The Tukwila Fire Prevention Bureau. Date: l e l t. S t z By: NOTICE completed, signed, Tukwila * VOLTAGE DROP = 7, 44% Fire Department Pre-test Ctificate must be presented wxwwwwww*0 the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. z 0 LU LU Cf) LU J w 0 REV. BY: 2 0 DESCRIPTION 0 z 4 0 0 1 DATE N 0 0 zaaaaa 1 1 TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. and exact address for shut down or restnratIon approval, PAID OCT -92012 TUKWILA FIRE cc , /a) 0 0 co 0 Jr m� J(3) ZZ < oO <r ZV �W... 1-1 �Q) vd©< T � ((0 <0 tr LL 1 -1 - SYMBOLS 1 - 4CALE: AS NOTED DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 10/08/12 BACKROUND PLAN PROVIDED BY: \0B NUMBER: 55559 'WIRE DESIGNATION CALCULATIONS Copyright 2002 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -01 , ©COPYRIGHT 2012 BY CHUBB FIRE & SECUIRTY SEATTLE: ALL RIGHTS RESERVED. CAD FILE: M:\Projects\2012\12-1010 DHS Bldg ICE 4th Fl TI\Engineering\CAD files\FAS Drawings RevO\12-04-1010 DHS 4th Floor FAS Layout.dwg IPLOT DATE: 13—Feb-2012 SYMBOL LEGEND SYMBOL QTY DESCRIPTION MOUNTING REQUIREMENTS SUPPLIER PART NUMBER D 5 INTELLIGENT PHOTO SMOKE DETECTOR 4 SQUARE DEEP wl 3" ROUND RING NOTIFIER FSP -851 w/B210LP BASE r 1 PAIR 14AWG FIRE RATED CABLE (FPLP) 60993B 3 CEILING SPEAKER wl STROBE 4 SQUARE DEEP wl EXT RING; CENTER ON CEILING TILE SYSTEM SENSOR SPCW O — FIRE ALARM SYSTEM "J" BOX SIZED FOR CONDUCTOR FILL NOTES: SUPPLIED BY ELECTRICAL CONTRACTOR 1 -WIRE MANUFACTURER IS FOR REFERENCE PURPOSE ONLY. WHEN USING OTHER MANUFACTURE, ENSURE PROPER CROSS REFERENCE 2- FPLP CAN BE USED IN MOST ALL APPLICATIONS WITH THE EXCLUSION OF WET AND CIRCUIT INTEGRITY REQUIREMENTS 3- INSTALL WIRING PER NEC. USE CABLE TYPE CONSISTENT WITH NEC REQUIREMENTS, IE: PLENUM, RISER, UNDERGROUND, ETC. 4- THE "Y" FIBER OPTIC CABLE LISTED ISA BELDEN CABLE PART NUMBER AS WEST PENN NO LONGER SUPPORTS FIBER OPTIC CABLE 5- THIS CABLE MUST BE INSTALLED IN A CONTINUOUS PATH POINT-TO-POINT. ABSOLUTLEY NO SPLICES ARE ALLOWED. Notes: 1- DEVICES SHOWN FOR IDENTIFICATION ONLY 2- DEVICES SHOWN ON DRAWINGS IN GRAY SCALE ARE EXISTING DEVICES AND MAY NOT BE INCLUDED IN THE ABOVE SYMBOL LEGEND 3- SET HORNISTROBE DECIBLE SETTING TO LOW FROM FACTORY SETTING OF HIGH, ONLESS OTHERWISE NOTED ON THE DRAWINGS. 4- THIS DEVICES REQUIRES THE USE OF A WP BACKBOX. WIRE LEGEND SYMBOL DESCRIPTION WEST PENN PiN COLOR CODING TYPE OF CIRCUIT APPLICATION NOTES D 1 PAIR 16AWG TWISTED 1 NON SHIELDED FIRE RATED CABLE (FPLP) 60991B RED JACKET wl NO STRIPE DATA (SLC) CIRCUIT CONTACT: Kurt Preissler S 1 PAIR 14AWG FIRE RATED CABLE (FPLP) 60993B RED JACKET wl WHITE STRIPE STROBE (NAC) CIRCUIT FAX: 206.763.0505 V 1 PAIR 16AWG TWISTED 1 SHIELDED FIRE RATED CABLE (FPLP) 60990B RED JACKET All YELLOW STRIPE SPEAKER (AUDIO) CIRCUIT BUILDING OWNER: NAME: Sabey Corp NOTES: "STRIPES ARE NOT REQUIRED, HOWEVER IT DOES MAKE IT EASIER FOR CIRCUIT IDENTIFICATION. 1 -WIRE MANUFACTURER IS FOR REFERENCE PURPOSE ONLY. WHEN USING OTHER MANUFACTURE, ENSURE PROPER CROSS REFERENCE 2- FPLP CAN BE USED IN MOST ALL APPLICATIONS WITH THE EXCLUSION OF WET AND CIRCUIT INTEGRITY REQUIREMENTS 3- INSTALL WIRING PER NEC. USE CABLE TYPE CONSISTENT WITH NEC REQUIREMENTS, IE: PLENUM, RISER, UNDERGROUND, ETC. 4- THE "Y" FIBER OPTIC CABLE LISTED ISA BELDEN CABLE PART NUMBER AS WEST PENN NO LONGER SUPPORTS FIBER OPTIC CABLE 5- THIS CABLE MUST BE INSTALLED IN A CONTINUOUS PATH POINT-TO-POINT. ABSOLUTLEY NO SPLICES ARE ALLOWED. FLAGNOTES NOTE # DESCRIPTION 34 DEVICE ADDRESS ASSIGNED BY DETECTION LOGIC FIELD TECHNICIAN ONCE ON-SITE D - (+i D OTA LOOP D D DEVICE ONE -LINE LAYOUT A AS SHOWN ON FLOOR PLANS TERMINATION OF WIRE AT DEVICE —171 YES NO B710LP INTELLIGENT BASE for SMOKE & HEAT DETECTORS SCALE: NONE LAST MODIFIED ON: AUG. 5 2009r1 FILENAME FA -011.._1 -A-1 z 4 -WIRE CONFIGURATION • DEV ICE ONE -UNE LAYOUT A AS SHOWN ON FLOOR PLANS s HIGH AUDIO OUT HIGH AUDIO IN TERMINATION OF WIRE AT DEVICE YES NO 4 SS ADVANCE SERIES SPEAKER/STROBE MOUNTING PLATE SCALE: NONE LAST MODIFIED ON: AUG 7, 200911 FILENAME FA-DTL3-C-3 FIRE ALARM GENERAL NOTES: 1. INSTALLATION SHALL BE ACCOMPLISHED IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE AHJ's, NEC AND CONTRACT DRAWINGS 2, WIRE ROUTING IS DIAGRAMMATIC IN NATURE ONLY AND NOT INTENDED FOR ACTUAL CONDUIT ROUTING. 3. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ. 4. THE SYSTEM SHALL BE MONITORED BY A U.L. LISTED MONITORING STATION BEFORE AHJ TEST. 5. VERIFY ALL LOCATIONS OF DEVICES WITH ELECTRICALIARCHITECTURAL PLANS. SCALE AND PLACE ALL DEVICE PER ELECTRICALIARCHITECTURAL PLANS. 6. FIELD VERIFY WATERFLOW, SMOKE DAMPERS AND DUCT DETECTORS LOCATIONS. 7. FIELD VERIFY ALL WIRING LOCATIONS AND REQUIREMENTS FOR HVAC AND FAN CONTROL. 8. SMOKE DETECTORS SHALL NOT BE LOCATED WITHIN 36" OF ANY AIR DIFFUSER. 9. NFPA72 (2002) 5.7.1.11 REQUIRES THAT NO DETECTORS SHALL BE INSTALLED UNTIL AFTER FINAL CONSTRUCTION CLEAN-UP. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO CLEAN-UP MUST BE CLEANED OR REPLACED AND WILL BE INVOICED ON A T&M BASIS. 10. FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF CHUBB FIRE & SECURITY TECHNICIANS. 11. ALL CIRCUITS WILL BE PROPERLY TAGGED AND TESTED FOR OPENS, SHORTS, GROUNDS AND PROPER "END -OF -LINE" RESISTANCE EACH CIRCUITS METER READING MUST BE DOCUMENTED AND PRESENTED TO CHUBB FIRE & SECURITY FIELD TECHNICIAN UPON ARRIVAL ONSITE FOR STARTUP & CHECKOUT. 12. A SET OF INSTALLATION AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY CHUBB FIRE & SECURITY TECHNICIAN, 13. AGREEMENT AND CONFIRMATION OF ALL MILESTONE EVENTS WILL BE MADE WITH CHUBB PROJECT MANAGER. ALL CHUBB FIELD SERVICES MUST BE SCHEDULED WITH CHUBB PROJECT MANAGER WITH A MINIMUM OF 10 WORKING DAYS ADVANCE NOTICE. 14. NO TAPPING OF SIGNALING OR INITIATING ZONE CIRCUITS ARE ALLOWED. T -TAPPING OF STYLE 4 ADDRESSABLE CIRCUITS IS ALLOWED PROVIDING A SPLICE IS PROFESSIONALLY INSTALLED, POLARITY IS OBSERVED AND SHIELDS ARE CONTINUOUS AND FREE OF GROUNDS. SHIELDS MUST BE TERMINATED AT FACP ONLY. CABLE SHIELDS SHALL BE SPLICED TOGETHER AT EVERY JUNCTION BETWEEN THE FACP AND THE LAST DEVICE ON EACH CABLE RUN. SHIELDS AND OTHER FIRE ALARM CONDUCTORS (EXCEPT POWER GROUNDS) SHALL BE INSULATED AND COMPLETELY FREE FROM CONDUIT OR EARTH GROUNDS. SHIELDS WILL BE TIES TO GROUND ONLY AT THE FACP BY THE CHUBB FIELD TECHNICIAN. 15. MOUNT AUDIBLENISUAL DEVICE BACKBOX BETWEEN A MINIMUM OF 80' AFF TO A MAXIMUM OF 96" AFF. SEE FLOOR PLANS FOR CANDELA RATING OF EACH DEVICE INSTALLED. 16. • AS-BUILTS ARE REQUIRED AT TIME OF AHJ ACCEPTANCE. CHUBB FIRE & SECURITY REQUIRED ELECTRICAL RED LINES WITHIN 2 WEEKS PRIOR TO AHJ TESTS. 17. NO LINE VOLTAGE IN SAME CONDUIT AS POWER LIMITED FIRE ALARM CABLE. 18. ALL MANUAL PULL STATIONS ARE TO BE MOUNTED ATA HEIGHT NO GREATER THAN 48" TO TOP AND NO LOWER THAN 36" TO BOTTOM, AREA OF WORK ,a9 ::5 DEVICE DESIGNATION LEGEND: (ONYX) ADDRESSABLE INITIATING DEVICES: PANEL SIGNAL LOOP CIRCUIT (SLC) L E "D"=DETECTOR M': MODULE DEVICE ADDRESS '12x" PLUS '127" NOTE: A DETECTOR & MODULE MAY HAVE THE SAME FIELD ADDRESS EXAMPLE: D D D s IA. bs : 1D127 D 1M127 REMOVE TAB ON DIAL FOR ADDRESSES 100 AND ABOVE NOTIFICATION I VISUAL CIRCUITS: CIRCUIT TYPE: 'C° = FACP NAC CIRCUIT =APS NAC CIRCUIT 'P"=24VDC POWER CIRCUIT "Fr =24VDC RESET POWER CIRCUIT °S"=STROBE CIRCUIT 'V°= VOICEISPEAKER CIRCUIT T=AUDIO RISER CIRCUIT POWER SUPPLY OR AMP NUMBER • SUB -CIRCUIT NUMBER NOTIFICATION APPLIANCES: 'I BELL SIZE DESIGNATION "6'=6'BELL =8" BELL '10°=10" BELL '12'=12" BELL A 9N" WITHIN THE DEVICE INDICATES THAT THIS DEVICE IS WEATHERPROOF STROBE CANDELA DESIGNATION '5' =15cd ' 6°-60cd ' T=75cd '9" = 95cd '0'=110cd ' 15°=115cd '35'=135cd '50':150cd '77° :177cd '85°:185cd 'H'=HORN ONLY : SPEAKER ONLY 0 Without Comments As Noted in Red Per The Attached Letter nese plans have b viewed by The Tukwila Fire :,;,�� _ . - • rgos forrmance with current ti :ndards, Accepr20-' , subject to errors and :Iisslons WhICh do not authorize violations of adopted Dnoaros and ordinances, The responsibility for the }quElcy of design ; c: ats totally with the designer. iit;onS, deietioi rs or revisions to these drawings after date +•slit void this z cceptarlce and will require a vsub rriittai of revised drawings for subsequent approval. 'nal acceptance Is subject to held test and inspection. by he Tukwila Fire Prevention Bureau. aate: TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit N0. wand exact add ess for shut - &o wr or re storto l'5Drr'I ovd . Iii PROJECT CONTACT INFORMATION; CUSTOMER;. NAME: Veca Electric ADDRESS: 5614 7th Ave S Seattle, WA 98108 CONTACT: Kurt Preissler PHONE: 206.696.7454 FAX: 206.763.0505 EMAIL: kur.preissler@veca:com BUILDING OWNER: NAME: Sabey Corp ADDRESS: 12201 Tukwila International Boulevard Seattle, WA 98168 CONTACT: PHONE: (206) 281-8700 FAX; EMAIL: BUILDING OWNER: NAME: Sabey Construction ADDRESS:12201 Tukwila Intemational Boulevard Seattle, WA 98168 CONTACT: PHONE: (206) 281.8700 FAX: EMAIL; FIRE ALARM / LIFE SAFETY PROVIDER: NAME: DETECTION LOGIC FIRE PROTECTION ADDRESS: 21312 30TH DRIVE SE, SUITE #103 BOTHELL, WA 98021 PHONE: 425-486-2600 FAX: 425-486-2611 SALESMAN: Joe Skvada joe.skvarla@fs.utc.com EXT: 7616 PROJECT MANAGER: Tony Barging tony.bartling@fs.utc.com EXT: 7604 DESIGNER: Larry Hales •Iarry.hales@fs.utc.com EXT: 7623 00> { A: OPEN OFFICE AREA \—_J FIN. CLG. HEIGHT 9'-4" (102 - AREA OFWORK -- OFFICE \---/ FIN. CLG. HEIGHT. 9'-4" RELOCATE 1 I 1 STAIR #3 C NOTICE A completed, signed, Ti..ikwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Act.:entance.. Testing of any Firs and Detection Sys Failure of test will r:in a Re -inspection Fi" '1 termination of thc: CORRIDOR 11491 3 05 11117 / STORAGE 1T489 OPEN %Ainnv A fl r A (14TH FLOOR TI FAS DEMO LAYOUT )SCALE: I/8' • I' A FIT ROOM FIN. CLG. HEIGHT 9'-4" L, /A\ TRAINING ROOM �FiN. CLG. HEIGHT RUPT UiT FROM EXISTING I 0‘ PT CIRCUIT 'STING TII SPAC. 02/13/12 till):: • nuiii11111 111111,i, 11 1 J. 11 f i I; C i dl i:.i .J \ i . 1 3 �. 4TH FLOOR TI FAS LAYOUT SCALE: 118' = I'-0' D PAI® FEBi42012 TUKWILFIRE - ���►� S m SCALE: in =1'43" 16 8 6 4 2 0 a N w FIRE MARSHAL REVIEW COMMENTS 5 �.l.r SCALE: 118' =1%0" DEVELOPEMENT RELEASE DATE: 0210912012 WHEN PRINTED ON ARCH -D (24x36) FIRE ALARM SYSTEM LEVEL 4 FAS LAYOUT DNS 4TH FLOOR TI FA -2.1 8021 OFFICE OF HOMELAND SECURITY CIS GROUP 12500 INTERNATIONAL BLVD.; SUITE 300 TUKWILA, WA 98168 CODE INFORMATION BUILDING CODE: 2006 INTERNATI❑NAL BUILDING CODE 2006 INTERNATI❑NAL FIRE CODE 2006 INTERNATI❑NAL MECHANICAL CODE WASHINGT❑N STATE AND CITY OF TUKWILA AMENDMENTS TO CODES LISTED ABOVE BUILDING CODE AUTHORITY: CITY OF TUKWILA OCCUPANCY: GROUP B CONSTRUCTION TYPE:1-B FIRE PROTECTI❑N: FULL SPRINKLER COVERAGE PER NFPA 13 BUIDLING AREA: 3,584 SQ FT CALCULATIONS FIRE ALARM BOOSTER POWER SUPPLY BATTERY CALCULATION Project: Office of Homeland Security TI Modifications Panel: PAD -3 w/Siemens Notification Appliances Date: May 26, 2010 Module/Device Qty Standby Total Standby Alarm (mA) (mA) (mA) Total Alarm (mA) Power Module 75 80 0 100 100 0 A TOTAL FIRE ALARM POWER SUPPLY 80 100 B Auxiliary Device Current 0 C Notification Appliance Load (Max. Load) F G H I J 5302 Tota I(A)= CALCULATION 80 Total(B)= 5402 Total current ratings of all devices in system (line A + line 8 + line C) 80 5402 Total current ratings converted to amperes (line D x .001) 0.08 5.402 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 RESUBMITTAL PER CITY OF TUKWILA Multiply lines E and F Total Standby AH 1.92 REMOTE POWER SUPPLY Alarm sounding period In hours (5 mins+ .0833 hours) NOTIFIER 0.0833 Multiply lines E and H Total Alarm AH PSx 0.4499866 Add lines G and I Total Standby and Alarm AH 2.3699866 ADDRESSABLE SMOKE DETECTOR Multiply line J by 1.2 (20% extra Insurance to meet desired performance) 2.84398392 PROVIDED Amp Hour Battery Provided 7.5 Amp Hour Notification Appliance Circuit Detail PROJECT: Office of Homeland Security TI Modifications Panel: PAD -3 w/Siemens Notification Appliances Date:May 26, 2010 CIRCUIT:.PS1 QTY Device Type 2 ZR -MC -C @ 15cd _.__.� 1 ZR-MC-C�30cd 3 ZN-MC-C @ 15cd 1 ZN-MC-C @ 95cd DEVICES=47 CURRENT TOTAL= 5302 Alarm Current. Harm Total , Wire Size Wire length Voltage at EOL i Circuit Total 69. 138. 111, 111: 871 261; 292! 292; TOTAL mA=1 802. 14 150 23.232486 :CIRCUIT: PS2 QTY Device Type 1Alarm Current, Alarm Total 1 Wre Size DEVICES= 1 TOTAL mA=1 15001 14 150 22.56451 ( Wire Length I Voltage at EOL Circuit Total QTY , Device Type ;Alarm Current; Alarm Total Wire Size DEVICES= 1 TOTAL mA=: 1500: 14 CIRCUIT: PS4 QTY Device Type Alarm Current i Alarm Total . Wre Size DEVICES=I1 1 TOTAL m A=1 1500: 14 Wre Length 400 Wre Length 550 15001 Voltage atEOL ! Circuit Total 20.172 Voltage at EOL 18.7365 1500 Circuit Total 1500 TYPICAL WIRING AND MOUNTING FROM FACP. PAD -3 OR PREVI❑US DEVICE TYPICAL HORNiSTROBE WIRING DETAIL SCALE: NONE TO NEXT DEVICE OR END OF LINE RESIST❑R CEILING TILE Q CEILING STROBE 4" SQUARE DEEP BOX CADDY SUPPORT BRACKET TYPICAL MOUNTING FOR CEILING HORN/STROBE & STROBE SCALE: NONE GENERAL NOTES LEGEND 1. ALL EQUIPMENT SHALL BE U.L. LISTED 2. ACCESS PANELS TO AREAS THAT REQUIRE SERVICING, TROUBLESHOOTING ETC. PROVIDED BY OTHERS 3. DO NOT DEVIATE FROM CONDUIT RUNS AS SHOWN ON FLOOR PLANS WITHOUT PRIOR APPROVAL FROM SYSTEM SUPPLIER (GUARDIAN SECURITY SYSTEMS, INC. TEL. 206-622-6545). FACTORS SUCH AS EXCESSIVE VOLTAGE DROP, ADDITIONAL PARTS, ENGINEERING, ETC. THAT ARE A RESULT OF CONDUIT RUN DEVIATIONS SHALL BE THE SOLE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. DO NOT INSTALL END OF LINE RESISTORS IN ANY HIGH BAY CEILING DEVICE. 4. DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIRFLOW, NOR CLOSER THAN 3'-0" (900mm) FROM AN AIR SUPPLY DIFFUSER. 5. ALL 120VAC POWER REQUIREMENTS FOR THE FIRE ALARM SYSTEM SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR AND SHALL MEET ALL REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 6. ALL FIRE ALARM DEVICE BACK BOXES, FIRE ALARM TERMINAL CABINETS, GUTTERS, JUNCTION BOXES AND ASSOCIATED CONDUITS SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. REFER TO FIRE ALARM SYMBOL LIST AND/OR MOUNTING DETAILS FOR ADDITIONAL INFORMATION. SYSTEM SUPPLIER PROVIDED BACK BOXES SHALL BE INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. 7. SMOKE DETECTOR TESTING SHALL BE ACCOMPLISHED PER THE MANUFACTURER'S INSTRUCTIONS. 8. ALL WIRING, INITIATING DEVICES AND ANNUNCIATOR PANELS SHALL BE SUPERVISED TO THE PRINCIPAL POINT OF ANNUNCIATION. THE FIRE ALARM CONTROL PANEL TO SUPERVISE THE ANNUNCIATOR PANEL, ALL INITIATING AND INDICATING DEVICE CIRCUITS. 9. ALL WIRING SHALL BE CUT FOR IN AND OUT. WIRING SHALL NOT BE LOOPED THROUGH DEVICES. ALL SPLICED WIRE POSSESSING SHIELDS SHALL HAVE SHIELDS SPLICED AND TAPPED TO TAPED TO PREVENT GROUND FAULTS. 10. POINT AND COMMON ANNUNCIATION AND T -TAPPING (EXCEPT SLC LOOP) ARE PROHIBITED. 11. THE ALARM SYSTEM SHALL HAVE AN AUDIBILITY OF NOT LESS THAN 15dB ABOVE AMBIENT NOISE LEVELS. TESTING SHALL BE ACCOMPLISHED WITH A dB METER. 12. ALL DEVICES IN THE ALARM SYSTEM SHALL BE COMPATIBLE AND INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 13. FIRE ALARM SYSTEM INSTALLATION COMPANY SHALL BE U.L. LISTED (UUJS). 14. INSTALLATION SHALL BE IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE, NEC AND CONTRACT DRAWINGS. 15. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ. 16. THE FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF M.S. TECHNICIANS. 17. A SET OF INSTALLATION AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY G.S.S. FIELD TECHNICIANS. AC ❑. Without Comments lam' As Noted in Red ❑ Per The iortached Letter These plans have !}:'.carr r'E'v;ewed by The Tukwila Fire Prevention Bureau to( conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to thesedrawingsafter this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is, uL:ct to field test and inspection by The Tukwila Fire Pi evention Bureau. Date: g 0 `10 By: t aiLtvP .LA FIRE DEPART + - tit Please call: 575-4407 end give this 1013 Nb. /O -F_ 17 3 and exact address for shut. town or restoration aon,rnv t 7`A'Ii t1s 0Le✓ices 4-0 Le. po'iw+ ltd cht04. NOTICE , A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance, Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the tecl-inn, QTY SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT E I Des I FIRE ALARM CONTROL PANEL NFS640 NOTIFIER PROVIDED 66" A.F.F. FACP RESUBMITTAL PER CITY OF TUKWILA E REMOTE POWER SUPPLY FCPS24 NOTIFIER PROVIDED 66" A.F.F. PSx 15 A ADDRESSABLE SMOKE DETECTOR FSP851 8701 BASE NOTIFIER PROVIDED 66" A.F.F. 3 ® CEILING MOUNT STROBE X=Candela Setting SCW SYSTEM SENSOR 4S DEEP BOX CEILING 5SPEAKER/STROBE Z CEILING MOUNT4S X=CANDELA SETTING SPSCW SYSTEM SENSOR DEEP BOX w/ 1-1/2" EXT. RING CEILING WIRE SCHEDULE WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS MIN. SIZE TYPE COLOR CODE D R P S S' x V V' DATA LINE -ADDRESSABLE LOOP RELAY CONTROLLED CIRCUIT DEVICE POWER - 24VDC SIGNALING CIRCUIT - STROBE FEED SIGNALING CIRCUIT - STROBE RETURN SUPERVISED CONVENTIONAL CIRCUIT SUPERVISED VOICE CIRCUIT FEED SUPERVISED VOICE CIRCUIT RETURN 2 2 2 2 2 2 2 2 #16 #14 #14 #14 #14 #18 #16 #16 FPLP FPLP FPLP FPLP FPLP FPLP TWISTED PAIR TWISTED PAIR RED-, BLK+ RED-, BLK+ RED-, BLK+ RED-, BLK+ RED-, BLK+ RED-, BLK+ RED-, BLK+ RED-, BLK+ SHEET INDEX SHEET FA -01 DESCRIPTION CODE INFORMATION, INDEX, LEGEND, GENERAL NOTES, CALCULATIONS, TYPICAL WIRING AND MOUNTING FA -02 FLOOR PLAN & REFLECTED CEILING PLAN FAX (206) 628-4990 TEL. (206) 622-6545 rn z 0 UJ IY w C/) Lu -J Lu IREV. BY: I Des I V) V) CO 0 z 0 1-- 0 c U C/) uJ c) SUBMITTED FOR APPROVAL RESUBMITTAL PER CITY OF TUKWILA DATE 0 tri N in 08/02/10 I «in (1) Z dao a CC °W co tqp O EJ BEI< �J3 WoZ W °g 1- � >- z -- o Lu Li.o WL r QLL N LL W or LL CI) D V LJJ F- aetC CC LIJ LL! CD LLQ CDW LL1 CC O ID O �CALE: 1/8" = DRAWN BY: D. SAGRELIUS DESIGNED BY: D. SAGRELIUS DATE: 05/26/10 BACKROUND PLAN PROVIDED BY: EVERGREEN POWER SYS. \OB NUMBER: 5498iy SHEET Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved J ARAOWORK CIS GROUP 3,584 SFZ OF OFFICE i u u u i MaMIIMA-1 EMI MEI MI MIN I= ME •� ■ • 1 E n eln WORK ROOM O 001 1011 101 1101 EMI O 011 CE E ll 1111 1101 CU 011 113 001 CIE 1111 En en '11E111111111111111111111111111111111111111 lays FLOOR PLAN COMPUTER I AREA OF WORK CIS GROUP 3,584 SF OF OFFICE TELEPHONE ■ • • ,,_% • 1 CIE112 CU 011 1111 011 Ell E ll E ll 011 1111 Ell 11111 1011 112 011 U M Ell 11011 011 E ll O 11 011 101 E ll E ll ICI EV ICS 1111 1 10 Ell WORK= ROOM® 1111 10 110 E ll 1111 1110 ISE E ll CIO Ell E N E ll E 1 1111 E S 1111 110 1111 1011 milli Ili I IF__ . , MEM MI MEE Ma ELV=1111E 1 361 -■ r - ii 7: : rmr.rAmmi 0 <- 4 ', I IIIIIIII11111111111111111111111111111■% COI ■ REFLECTED CEILING PLAN FAX (206) 628-4990 RELEASE/REVISIONS IREV. BY: I DBS V) D DESCRIPTION SUBMITTED FOR APPROVAL RESUBMITTAL PER CITY OF TUKWILA DATE 0 0 N cD O N in o o z aaaaa 2 z 0 z 0 0 W 0 W J LIL W o a z 0 0 0 SCALE: 1/8" = 1'-0"-‘\ DRAWN BY: D. SAGRELIUS DESIGNED BY: D. SAGRELIUS DATE: 05/26/10 BACKROUND PLAN PROVIDED BY: EVERGREEN POWER SYS. \OB NUMBER: 54988) I. SHEET FA -02 Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved © COPYRIGHT 2008 BY DETECTION LOGIC SEATTLE: ALL RIGHTS RESERVED. CAD FILE: M:\Projects\Core&Shell\DHS Bid — Tukwila\09-2046 ICE + CIS TI\Engineering\CAD Files\FAS Drawings RevO\09-04-2046 FA -000 General Notes & Info.dwg PLOT DATE: 03—Sep-2009 Symbol Legend SYMBOL CIS TI QTY ICE 11 QTY DESCRIPTION MOUNTING REQUIREMENTS MANUFACL PART NUMBER 609911 15 13 Intelligent Photo Smoke Detector 4 Square Deep w13" Round Ring Notifier FSP -851 wIB710LP base Data (SLC) Circuit G 1 pair 16AWG Fire Rated Cable (FPLP) 5 5 Ceiling Speaker wl Strobe 15cd: White 4 Square Deep wI Ext Ring; Center on Ceiling Tile Notifier SPSCW Pink 2 2 Ceiling Speaker wl Strobe 30cd: White 4 Square Deep wI Ext Ring; Center on Ceiling Tile Notifier SPSCW a 2 60993 Ceiling Speaker wI Strobe 75cd: White 4 Square Deep wl Ext Ring; Center on Ceiling Tile Notifier SPSCW OO Red Jacketwl Neon Green Stripe 1 Ceiling Strobe 15cd: White 4 Square Deep; Center on Ceiling Tile Notifier SCW Strobe (NAC) Circuit T 2 pair 24AWGTelephone Cable CATS Grey Jacket Telephone Circuit U Notes: 1. Device shown for identification only 2" Existing Devices in Gray Scale 3. Current Sensing Relay for 120VAC Applications: Use Functional Devics # RIBXGHTA (120VAC 0.75-150A) 4. Current Sensing Relay for 480VAC Applications: Use Functional Devices # RIBXLCRA (480VACI3-Phase 1.5.150A) Wire Legend SYMBOL DESCRIPTION VEST PENN P.N. COLOR CODING TYPE OF CIRCUff APPLICATION A 1 pair 16AWG Fire Rated Cable (FPLP) 609911 Red Jacketwl No Stripe Conventional (IDC) Circuit D 1 pair 16AWG Twisted I NON Shielded Fire Rated Cable (FPLP) 60991 Red Jacket wI No Stripe Data (SLC) Circuit G 1 pair 16AWG Fire Rated Cable (FPLP) 60991B Red Jacketwl Black Stripe Aux Relay Interface L 2 Cond.14AWG THHN (in EMT) Pink Aux Equipment Interface N 1 pair 16AWG Twisted I Shielded Fire Rated Cable (FPLP) D60990 Red Jacketwl orange Stripe 485 Network Circuit p 1 pair 14AWG Fire Rated Cable (FPLP) 60993 Red Jacketwl Neon Green Stripe Aux Power Circuit R 1 pair 14AWG Fire Rated Cable (FPLP) 60993 Red Jacketwl Neon Green Stripe ResettableAux Power Circuit S 1 pair 14AWG Fire Rated Cable (FPLP) 60993 Red Jacketwl White Stripe Strobe (NAC) Circuit T 2 pair 24AWGTelephone Cable CATS Grey Jacket Telephone Circuit U 1 pair 14AWG Fire Rated Cable (FPLP) 60993 Red Jacketwl White Stripe NAC Sync Circuit V 1 pair 16AWG Twisted I Shielded Fire Rated Cable (FPLP) 60990 Red Jacketwl Yellow Stripe Speaker(Audio) Circuit W 4 Cond.18AWG Fire Rated Cable (FPLP) 60982 Red Jacketwl It Blue Stripe Remote Test Station Circuit Notes: Wire Manufacturer is for Reference Purpose Only. When using other Manufacture, ensure proper Cross Reference FPLP can be used in most all applications with the exclusion of Wet and Circuit Integrity Requirements Install wiring per NEC. Use cable type consistant with NEC requirements, IE: plenum, riser, underground, etc. The T Fiber Optic cable listed is a BELDEN Cable part number as West Penn no longer supports Fiber Optic Cable Flag Notes NOTE # (DESCRIPTION 34 Device Address Assigend by Detection Logic Field Technican once On -Site Job Specific Flag Notes NOTE # 'DESCRIPTION 70 Remove existing device and convert 00J•Box only FIRE ALARM CHECKOUT: - FACP POWERED UP AND ON PERMANENT POWER - FACP IN NORMAL CONDI1ON - GREEN IJGHT - NO UNEXPLAINED FAULTS ON SYSTEM - FINAL OPERATIONAL PROGRAM COMPLETE AND LOADED INTO FACP - ALL CIRCUIT VERIFIED FOR PROPER EOCs VALUES, MEASURED AND RECORDED - CENTRAL STATION MONITORING ONLINE AND OPERATING - INITIAL PRE-TEST SPOT CHECKS COMPLETE 2- POTS PHONE LINES INSTAUED ELECTRICAL CHECKOUT: - CONNECTIONS TO SPRINKLER SUPERVISORY DEVICES COMPLETE - CONNECTIONS TO FANS, DAMPERS & OTHER MECH CONTROLS ARE COMPLETE - CONNECTIONS TO ELEVATORS (RECALL) COMPLETE - ALL CABLES AND/OR CONDUITS INSTALLED PER NEC70 REQUIREMENTS - ALL INITIATING DEVICES INSTALLED PER PLANS - ALL INDICATING DEVICES INSTALLED PER PLANS - ALL CIRCUITS ARE FREE OF GROUNDS, SHORTS & OPENS - ALL CIRCUITS HAVE BEEN MEASURED FOR THOR RESPECTIVE EOL VALUES AND RECORDED - ALL AC POWER SOURCES HAVE BEEN LABELED AT THEIR RESPECTIVE EQUIPMENT - DUAL PHONE UNES ARE INSTALLED TO THE FACP CENTRAL STATION MONITORING ONUNE FIRE ALARM PRETEST COMPLETE FIRE ALARM GENERAL NOTES: ACC EP E D Without Comments 1 As Noted in Red O Per The Attached Letter These plans_ have bezil rek4c..w'ed L?y The Tukwila Fire Prevention Bureau for cc : ;:;? _ v.!tfh current city standards. Acceptance , _ ` rs t_ and omissions which do n �, rzs of adopted standards and ordin nL=s 11)i1 =y for the � ;. , f :.requacy of design rests designer.. Additions, deletions or ,'EvLclon =` .....se drawings after this date will void this a4 Lp anc2 ar:-3 will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukvta Fire Prevention Bureau. Date: 9 - 8.0 C By: 1. INSTALLATION SHALL BE ACCOMPLISHED IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE AHJ's, NEC AND CONTRACT DRAWINGS 2. WIRE ROUTING IS DIAGRAMMATIC IN NATURE ONLY AND NOT INTENDED FOR ACTUAL CONDUIT ROUTING. 3. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ. 4. THE SYSTEM SHALL BE MONITORED BY A U.L. LISTED MONITORING STATION BEFORE AHJ TEST. 5. VERIFY ALL LOCATIONS OF DEVICES WITH ELECTRICALIARCHITECTRAL PLANS. SCALE AND PLACE ALL DEVICE PER ELECTRICALIARCHITECTURAL PLANS. FIELD VERIFY WATERFLOW, SMOKE DAMPERS AND DUCT DETECTORS LOCATIONS. FIELD VERIFY ALL WIRING LOCATIONS AND REQUIREMENTS FOR HVAC AND FAN CONTROL. SMOKE DETECTORS SHALL NOT BE LOCATED WITHIN 36" OF ANY AIR DIFFUSER. 6. 7. 8. 9. NFPA72 (2002) 5.7.1.11 REQUIRES THAT NO DETECTORS SHALL BE INSTALLED UNTIL AFTER FINAL CONSTRUCTION CLEAN-UP. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO CLEAN-UP MUST BE CLEANED OR REPLACED AND WILL BE INVOICED ON A T&M BASIS. 10. FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF DETECTION LOGIC TECHNICIANS. 11. ALL CIRCUITS WILL BE PROPERLY TAGGED AND TESTED FOR OPENS, SHORTS, GROUNDS AND PROPER "END -OF -LINE" RESISTANCE. EACH CIRCUITS METER READING MUST BE DOCUMENTED AND PRESENTED TO DETECTION LOGIC FIELD TECHNICIAN UPON ARRIVAL ONSITE FOR STARTUP & CHECKOUT. 12. A SET OF INSTALLATION AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY DETECTION LOGIC TECHNICIAN. 13. AGREEMENT AND CONFIRMATION OF ALL MILESTONE EVENTS WILL BE MADE WITH D.L. PROJECT MANAGER. ALL D.L. FIELD SERVICES MUST BE SCHEDULED WITH D.L. PROJECT MANAGER WITH A MINIMUM OF 10 WORKING DAYS ADVANCE NOTICE. 14. NO TAPPING OF SIGNALING OR INITIATING ZONE CIRCUITS ARE ALLOWED. T -TAPPING OF STYLE 4 ADDRESSABLE CIRCUITS IS ALLOWED PROVIDING A SPLICE IS PROFESSIONALLY INSTALLED, POLARITY IS OBSERVED AND SHIELDS ARE CONTINUOUS AND FREE OF GROUNDS. SHIELDS MUST BE TERMINATED AT FACP ONLY. CABLE SHIELDS SHALL BE SPLICED TOGETHER AT EVERY JUNCTION BETWEEN THE FACP AND THE LAST DEVICE ON EACH CABLE RUN. SHIELDS AND OTHER FIRE ALARM CONDUCTORS (EXCEPT POWER GROUNDS) SHALL BE INSULATED AND COMPLETELY FREE FROM CONDUIT OR EARTH GROUNDS. SHIELDS WILL BE TIES TO GROUND ONLY AT THE FACP BY THE D.L. FIELD TECHNICIAN. 15. MOUNT AUDIBLENIAUAL DEVICE BACKBOX BETWEEN A MINIMUM OF 80" AFF TO A MAXIMUM OF 96" AFF. SEE FLOOR PLANS FOR CANDELA RATING OF EACH DEVICE INSTALLED. 16. AS-BUILTS ARE REQUIRED AT TIME OF AHJ ACCEPTANCE. DETECTION LOGIC REQUIRED ELECTRICAL RED LINES WITHIN 2 WEEKS PRIOR TO AHJ TESTS. 17. NO LINE VOLTAGE IN SAME CONDUIT AS POWER LIMITED FIRE ALARM CABLE. 18. ALL MANUAL PULL STATIONS ARE TO BE MOUNTED AT A HEIGHT NO GREATER THAN 48" TO TOP AND NO LOWER THAN 36" TO BOTTOM. TOS EA FIRE DEPART Reese call: 575-4407 arid give this job and exact address for shut" down or restoration at pro Pore addresygS:I1J./ ret,n4 £4- (e%4.1.( 54c 4"1)►•- 4K 1 Fn' to_ MECHANICAL CHECKOUT: - ALL UFESAFTEY FANS ARE INSTALLED AND OPERATING - ALL DAMPERS (FIRE & SMOKE CONTROL) ARE INSTALLED AND OPERATING - AU. FIRE ALARM INTERFACES ARE COMPLETED AND VERIFIED FOR OPERATING - HVAC SYSTEM HAS BEEN BALANCED - EMERGENCY GENERATORS ARE INSTALLED AND OPERATING - ALL AC POWER SOURCES HAVE BEEN LABELED AT THEIR RESPECTNE EQUIPMENT SPRINKLER CHECKOUT: - ALL SPRINKLER SUPERVISORY DEVICES ARE INSTALLED AND PROPERLY OPERATING - ALL FIRE PUMP CONTROLLERS ARE INSTALLED AND OPERATING PROPERLY - SPRINKLER SYSTEM IS CHARGED AND READY FOR FULL OPERATION ELEVATOR CHECKOUT: - ELEVATOR MACHINE ROOMS ARE COMPLETE - ELEVATOR CABS TRIMMED OUT, INCLUDING ANY FA DEVICES - ELEVATOR SHUNT TRIP SYSTEM OPERATIONAL ON ALL MACHINE ROOMS MECHANICAL PRLILSI COMPLETE SPRINKLER PREILSI COMPLETE ELEVATOR PRLIL51 COMPLETE FULLY FUNCTIONAL PRLILSI COMPLETED INCLUDING CONNECTIONS AND CONTROLS FOR ALL DISCIPLINES ELECTRICAL FINAL COMPLETE MECHANICAL FINAL COMPLETE NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presenti to the Inspector prior to commencement of`Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. SPRINKLER FINAL COMPLETE ELEVATOR FINAL COMPLETE STANDARD FA PERMIT FLOWCHART FIRE ALARM FINAL CANNOT BE COMPLETE UNTIL PERMITS FROM ETEC, MECH, SPRINKLER AND ELEV ARE SIGNED OFF. 6.0 DEVICE DESIGNATION LEGEND: (ONYX) ADDRESSABLE INITIATING DEVICES: PANEL SIGNAL LOOP CIRCUIT (SLC) DEVICE ADDRESS "127" "D"= DETECTOR "M° = MODULE NOTE: A DETECTOR & MODULE MAY HAVE THE SAME FIELD ADDRESS D 5 1D127 EXAMPLE: D D 65 D 1M127 s REMOVE TAB ON DIAL FOR ADDRESSES 100 AND ABOVE NOTIFICATION 1 VISUAL CIRCUITS: CIRCUIT TYPE: "C" = FACP NAC CIRCUIT "N" =APS NAC CIRCUIT "P" = 24VDC POWER CIRCUIT "R" = 24VDC RESET POWER CIRCUIT "S" = STROBE CIRCUIT "V" = VOICEISPEAKER CIRCUIT "Z" =AUDIO RISER CIRCUIT POWER SUPPLY OR AMP NUMBER d SUB -CIRCUIT NUMBER NOTIFICATION APPLIANCES. BELL SIZE DESIGNATION "6"=6"BELL "8"=8"BELL "10" =10" BELL "12"=12"BELL A "W" WITHIN THE DEVICE INDICATES THAT THIS DEVICE IS WEATHERPROOF STROBE CANDELA DESIGNATION "5":15cd "3': 3ocd "6"=6ocd "7': 75cd 9"=95a1 "0" =11ocd "15" =115cd "35" =135cd "50"=150cd "77" =177cd "85" =185cd "H" = HORN ONLY "F" = SPEAKER ONLY SYMBOL & WIRE STYLE INDENTIFICATION 2C,D S b S x XX (011•11111MIE SI 111111111111111 • III • RACEWAY WIREICABLE INDENTIFIER 2C = 2 TYPE "C" CABLES D =1 TYPE "D" CABLE ENLARGED VIEWPORT DETAIL INDENTIFIER TOP LINE INDICATED DETAIL # BOTTOM LINE IS SHEET # ENLARGED VIEWPORT OUTLINE ■ ■ — SEE DETAIL IDENTIFIER . ■ .) 5- -s SMOKE CONTROL ZONE BOUNDRIES ADA ROOM BOUNDRIES RACEWAY REQUIRED TO BE INSTALLED UTILIZING A 2Hr PROTECTION METHOD AC POWER (120, 240 or 480VAC) DIRECTION OF AIRFLOW THROUGH FSD DEVICE WIRING DETAIL NUMBER SHEET SPECIFIC ITEM NOTE PROJECT CONTACT INFORMATION: CUSTOMER: NAME: VECA ADDRESS: 5614 7th Ave South Seattle,WA.98108 CONTACT: Nancy Dumont PHONE: 206-436-5200 FAX: 206-763-0505 EMAIL: BUILDING OWNER: NAME: Sabey Corporation ADDRESS: 12201 Tukwila International Blvd Tukwila,WA.98168 CONTACT: PHONE: FAX: EMAIL: FIRE ALARM I LIFE SAFETY PROVIDER: NAME: DETECTION LOGIC FIRE PROTECTION ADDRESS: 21312 30TH DRIVE SE, SUITE #103 BOTHELL, WA 98021 PHONE: 425-486-2600 FAX: 425-486-2611 SALESMAN: Mike Cunningham mike.cunningham@detectionlogic.com EXT: 7602 PROJECT MANAGER: Tony Bantling tony.bantling@detectionlogic.com EXT: 7604 DESIGNER: Larry Hales Iarry.hales@detectionlogic.com EXT: 7623 D D D D + FROMLOOP SLC DEVICE ONE -LINE LAYOUT AS SHOWN ON FLOOR PLANS s D TERMINATION OF WIRE AT DEVICE YES NO B710LP INTELLIGENT BASE for SMOKE & HEAT DETECTORS SCALE: NONE LAST MODIFIED ON: Jul. 7, 2009 FILENAME FA -DILL -A-1 FROM VOICE ) (+) CONTROL DEVICE ONE -LINE LAYOUT AS SHOWN ON FLOOR PLANS YES TERMINATION OF WIRE AT DEVICE NO SS ADVANCE SERIES SPEAKER/STROBE MOUNTING PLATE SCALE: NONE LAST MODIFIED ON: Jul. 7, 2009 FILENAME FA-DTL3-C-3 MOUNTING ISOMETRIC FOR DETECTORS & MODULES SCALE: NONE LAST MODIFIED ON: Jul. 7, 2009 FILENAME FA -D11_5 -D-1 CDMOUNTING ISOMETRIC FOR SPEAKER/STROBES SCALE: NONE LAST MODIFIED ON: Jul 7, 2009 FILENAME FA-DTL5-D-3 ?AID SEP — 4 2009 atcwila Fire 100% PERMIT SUBMITTAL SET 00 1-0 Lu w W CC ca jt) :61 be;WH aWD Or.. m 03 0 CC FIRE ALARM CONTRACTOR z r w PROJECT NAME z 00 fill ri o00 Gc3 GCI 1�1 F�1 Q.i 2:' cr) 0-4 @.) 'Irr4 U Cr) m w w SCALE: DEVELOPEMENT RELEASE DATE: 0612912009 FIRE ALARM SYSTEM GENERAL NOTES & INFO FAD000 © COPYRIGHT 2008 BY DETECTION LOGIC SEATTLE: ALL RIGHTS RESERVED. OFFICE 304 OFFICE r 305 j OPEN WORK AREA 13?G___1 CONFERENCE 30 1 CIS TI AREA OF WORK OFFICE 308 1mm11_11 11 11 •1 11, Olin ._.. 11•1111111111111111111111111=M I .. U1 — 11 D SHELL SPACE S5-1 S5-1 S5-2 (g) 3003 V1-12 1.00 L 00.Ii10Ik 'Logi ■ x ®i 1 1 100. ilamm, 1 00110 1 1.00,1III C ■ �—It1IIIIIM■■O■■—■1-11-11-11-11 •■■MM■■-1U—U Ute■■00■■ EXAM 304 303 I ;....... .2 OFFICE BREAK �. .._3 01._._..I RECEPTION ELECTRICAL 5-1 c 15-1 V1-! V1-12 (D- D,2P (17:- =D ..BREAK ROOM 35- 00 6 38- 1 r 8 - i V1-12 A 31 50 3010 2V /\ r2:• S5-2 OCATE 23,2V -<. i 'D ,F 3131 S,•v �vV-1 V1-12 •`J S,V D,P,V 3132 3133 V1-12 )) V1-12 /- I . X1145 C>-u'v 3014 38-1 30 2A V1-12 D 3134 D,P w S5-2 35-2 16 • 1- 1— CCi ge— CO cc EL• D co FIRE ALARM CONTRACTOR a. co.) 00 w o u 9 PROJECT NAME CC CO LLJ DEVELOPEMENT RELEASE DATE: 06129/2009 FIRE ALARM SYSTEM LEVEL 3 LAYOUT CIS TI FA -103 © COPYRIGHT 2008 BY DETECTION LOGIC SEATTLE: ALL RIGHTS RESERVED. i ■■m■■ieso■■ N■■ _■■ _ some _ mom ■._ ■■w■■ ®■. me 11 e■■ ..._ _._..... • PUBLIC ICE TI AREA OF WORK 1 1 �Y 1 it l 111 .1f.1 1 101 Immo 111 1 1 11'1 mena 1 1 arca 117II■i1III 1111111111 1 1 ®11Mill11r 1 I S9-2 V1-13 S9-2. _ 1 ��-S.2V V 8S-4 V1• • - 8 D 59 _ -SPACE ECLPTION AVS1-139-2 CORRIDO_R S9-2 V1-13. S,2V S9-2 6 V1-13 OFFICE v; TEL. <.58 i 302,3 i I :f/ 4 fi 1 --:{rim>+�[.. �'� 6j• '}. I 3021 , ICF ,SVA, D 1 � 3065 i. R 3087 (L, R IFSV i _5023 IY L-, ` IfaTh �I �.D) N D.L_ �'N AZT 2 3 CO.M STO T+: PUTER INING 89-3 -- D ........ . y V COR1 Rti 31:?5 ,,,1-1 - -- !`j r , 52 2; �z ,V1 13 ,� I=:TI F;—i j �0D,F ' (J --S I X01 Jr4 I Tl 83-3 CL>4 SSI E I E D 6oyFILL ROOM -- 18I I :i IDf i 3024 3091 1-61I41 "ArsiX S5- s S 5-3 J ® 30i8 5 P'.. �r R0C✓11 V1-8 t036 I-3 3019 V1-13 OFFICE V ;: :.:_ ,7777 SHR N --4 OPEN �, a■: 'REA.'t'- (y)— 8,V 66030 3072 8°-3 V1 w,na =KRDOM -t :FQ20 OPEN __ WORK -...AREA ' 89 I 6019 V1-131 _CONFEREN_CEL FA 6018 I (�., 89- 3 Ii i.- y. D DO OFFICE OFFICE OFFICE i OFFICE PLOT • U_ 0 00 o F- () W 1- ea 00 .. W C>c OQ ZY � X /1 W Z U pScn. c_LJ c.4 N M M 0 0 0 0 111 N N N N CO 0) aL .. 1- U CO mzzz 1- V, J 1— CO m 1--- w SCALE: $11=11-0" 0- 16 8 6 4 2 0 FIRE ALARM CONTRACTOR z 5 a >- PROJECT NAME 0 W m D C/1 U) @.) SCALE: 118" =11-0" DEVELOPEMENT RELEASE DATE: 0612912009 FIRE ALARM SYSTEM LEVEL 4 LAYOUT ICE TI FA -104 SYMBOL LEGEND 4th Floor Server 'oom Pre -action Fire Suppression System 12500 International SYMBOL SPK—X LECX" XXcd NX—X DBIE" XXcd NX—X XXcd SPK—X fflJl XXcd NX—X WP NX—X XXcd NX—X )XXcd " XXcd NX—X XXcd NX—X OXXcd NX—X X—X—X ffi ULU MTh 0 cJ EBB 0 DESCRIPTION SYNC. MULTI—CANDELA SPEAKER/STROBE * SUBSCRIPT INDICATES CIRCUIT # SYNC. MULTI —CANDELA HORN/STROBE • SUBSCRIPT INDICATES CIRCUIT # SPEAKER * SUBSCRIPT INDICATES CIRCUIT # HORN • SUBSCRIPT INDICATES CIRCUIT WEATHERPROOF BELL • SUBSCRIPT INDICATES CIRCUIT # SYNC. MULTI—CANDELA STROBE • SUBSCRIPT INDICATES CIRCUIT # SYNC. MULTI—CANDELA CEILING SPEAKER/STROBE • SUBSCRIPT INDICATES CIRCUIT # SYNC. MULTI—CANDELA CEILING HORN/STROBE • SUBSCRIPT INDICATES CIRCUIT CEILING SPEAKER SYNC. MULTI—CANDELA CEIUNG STROBE • SUBSCRIPT INDICATES CIRCUIT # ADDRESSABLE MANUAL PULL STATION * suBSCRIPT INDICATES DEVICE ADDRESS SUPPRESSION ABORT STATION SUPPRESSION RELEASE STATION ADDRESSABLE SMOKE DETECTOR SMOKE DETECTOR ADDRESSABLE HEAT DETECTOR FT/ROR • SUBSCRIPT INDICATES DEVICE ADDRESS 1357T HEAT DETECTOR • SUBSCRIPT INDICATES DEVICE ADDRESS ADDRESSABLE DUCT SMOKE DETECTOR • SUBSCRIPT INDICATES DEVICE ADDRESS REMOTE LED FLOW SWITCH PRESSURE SWITCH HIGH/LOW AIR TAMPER SWITCH POST INDICATOR VALVE LOW LEVEL INDICATOR SOLENOID VALVE SOLENOID RELEASE MODULE SERVICE DISCONNECT SUPPRESSION RELEASE EOL RELAY FIRE PUMP HEAT TRACE KITCHEN HOOD HVAC DAMPERS DOOR HOLDERS SIGNAL MODULE SYNCHRONIZED MODULE SINGLE—INPUT MODULE DUAL—INPUT MODULE UNIVERSAL INPUT/OUTPUT MODULE CONTROL RELAY REMOTE RELAY LCD ANNUNCIATOR ADDRESSABLE POWER SUPPLY NAC POWER EXTENDER PANEL BATTERY CABINET FIRE ALARM CONTROL PANEL SUPPRESSION CONTROL PANEL FIRE ALARM TERMINAL CABINET ELECTRICAL JUNCTION BOX MODEL G4—S2VM (WHITE) G4R—S2VM (RED) 01—HDVM (WHITE) G1R—HDVM (RED) G4—S2 (WHITE) G4R—S2 (RED) • Gl—HD (WHITE) G1R—HD (RED) 439D-10AR G1—VM (WHITE) G1R—VM (RED) GC—S2VM (WHITE) GCF—S2VM ("FIRE") GC—HDVM (WHITE) GCF—HDVM ("FIRE") GC—VM WO "FIRE") CCF—VM (W/ "FIRE") SIGA-278 RELA—ABT 278A—REL SIGA—PtS BY OTHERS SIGA—HRS 283B—PL SIGA—DH SIGA—LED BY OTHERS • 10170089 BY OTHERS BY OTHERS BY OTHERS BY OTHERS BY OTHERS SIGA—REL RELA—SRV RELA—EOL BY OTHERS BY OTHERS BY OTHERS BY OTHERS 1504—AQ SIGA—CC1S G1M SIGA—CT1 SIGA—CT2 SIGA—UM SIGA—CR MR -201 3—LCDANN SIGA—APS BPS -6 BC -1 EST -3 EST QS1-1—G-1 BY OTHERS BY OTHERS BACK BOX / DIMENSIONS 4" SQ, 2.125" DEEP BY EC SINGLE—GANG, BY E.C. 4" SQ, 2.125" DEEP BY EC SINGLE—GANG, BY E.C. #449 SINGLE—GANG, BY E.C. 4—S w/2.125" DEEP BY E.C. 4—S w/2.125" DEEP BY E.C. 4—S w/2.125" DEEP BY E.C. SINGLE—GANG, BY E.C. SINGLE—GANG BY E.C. SINGLE—GANG BY E.C. 4—P, BY E.C. BY OTHERS 4-0, BY E.C. 4-0, BY E.C. SELF—CONTAINED 4—S, 2" DEEP, BY E.C. BY OTHERS SELF—CONTAINED BY OTHERS BY OTHERS BY OTHERS BY OTHERS BY OTHERS MFC—A, 8" X 14" X 3.5" SINGLE—GANG BY E.C. SINGLE—GANG BY E.C. BY OTHERS BY OTHERS BY OTHERS BY OTHERS FLUSH WALL MOUNTED TWO—GANG, 2.5" DEEP BY E.C. PIGGY BACK SINGLE—GANG, 2.5" DEEP BY E.C. SINGLE—GANG, 2.5" DEEP BY E.C. TWO—GANG, 2.5" DEEP BY E.C. SINGLE—GANG, 2.5" DEEP BY E.C. SELF—CONTAINED 6.12L" X 12.1H" X 2.75D" RACCR BY AVAC 16.2" X 21" X 3.45" 17" X 13" X 3.375" 14" X 18.5" X 7" 14L" x 2237H" x 3.86D" 18" x 14.25" x 2.68" BY OTHERS BY OTHERS DESCRIPTION OF WORK: ye, ukwila, WA 98168 GENERAL NOTES: WIRE CODE THIS PROJECT INVOLVES THE INSTALLATION OF A NEW PRE -ACTION SUPPRESSION SYSTEM ON THE 4TH FLOOR SERVER ROOM. Sequence of Operation Smoke Detection 1st Cross -Zone Device in Alarm mo e • etection 2nd Cross -Zone Device in Alarm Waterflow Switch Low Switch Tamper Switch System Trouble Activation of Local Alarm at FACP (LCD Display & Audible Indication) X X X X Black / Orange TFN 16 Close Smoke/Fire Dampers X X X X Horn / Strobe D Close Mechanical Dampers X X X X 2 •Brown / Yellow THHN Activate Preaction Sprinkler Solenoid X X 2 Orange THHN 14 Fan Shutdown Alarm Contact Output to Building Fire Alarm Panel X X X X H 1 • Trouble/Supv. Indication at Suppression Control Panel 18 Serial Communication 2 X X Trouble/Supv. Contact Output to Building Fire Alarm Panel I 1 Twisted / Shielded Pair 16 X X 1) ALL WIRE AND CONDUIT MUST BE INSTALLED IN ACCORDANCE WITH PLANS AND SPECIFICATIONS, AND MUST MEET ALL APPLICABLE CODES. 2) ALL WIRE AND CABLE MUST BE RATED FOR FIRE ALARM USE PER THE LATEST REVISIONS OF THE NATIONAL ELECTRICAL CODE SECTION 760. THIS IS A POWER LIMITED FIRE ALARM SYSTEM, ALL CABLE MUST BE MARKED FPL, FPLR, CI OR FPLP. 3) ALL CONDUCTORS MUST TEST FREE OF GROUND BEFORE MAKING CONNECTION TO THE FIRE ALARM CONTROL PANEL. 4) TO RETAIN WARRANTY, THE FIRE ALARM EQUIPMENT MUST BE POWERED UP UNDER THE DIRECTION OF A QUALIFIED MANUFACTURERS TECHNICIAN. 5) THE LIFE SAFETY SYSTEM IS A COMPLETELY SUPERVISED SYSTEM. 6) INSTALLING ELECTRICAL CONTRACTOR SHALL COORDINATE ALL HELD CHANGES WITH THE FIRE ALARM CONTRACTOR INCLUDING CHANGES IN DEVICES, WIRE, CONDUIT RUNS AND OPERATION IN THE SYSTEM. FIRE ALARM CONTRACTOR SHALL NOT BE HELD RESPONSIBLE FOR UNDOCUMENTED CHANGES, OR THE RESULTS CAUSED BY THOSE CHANGES. 7) LIFE SAFETY AUDIBLE SHALL BE AUDIBLE THROUGHOUT THE SPACE AND SHALL HAVE A SOUND PRESSURE LEVEL NOT LESS THAN 15db ABOVE AMBIENT NOISE LEVEL MEASURED AT 4'0" ABOVE FINISHED FLOOR. 8) MAIN BUILDING FIRE ALARM Sc SUPPRESSION SYSTEMS SHALL BE CLASS "B" IN CONFIGURATION. PRE—ACTION & DELUGE ALARM SYSTEMS SHALL BE CLASS "A" IN CONFIGURATION. CLASS "A" APPLICATIONS SHALL MAINTAIN A MINIMUM SEPARATION OF 4 FEET BETWEEN FEED AND RETURN CIRCUITS. 9) LOCATE: ALL PULL STATIONS AND HORN/STROBE UNITS AT SPECIFIED HEIGHTS PER NFPA 72 AND ADA SEE DETAIL SHEET. 10) SMOKE DETECTOR LOCATIONS ARE FOR REFERENCE ONLY AND SHALL BE INSTALLED PER NFPA 72. 11) ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ROUGH—IN INSTALLATION WITH THE FIRE ALARM CONTRACTOR. 12) SMOKE: DETECTORS ON CEILINGS MUST BE NO MORE THAN 15' FROM A WALL AND/OR NO MORE THAN 30' FROM EACH OTHER. REDUCED SPACING MAY ALSO BE REQUIRED. SEE PLAN DRAWINGS FOR PROJECT—SPECIFIC LOCATIONS. 13) ALL FIRE ALARM DEVICES SHALL BE RIGIDLY AND SECURELY FASTENED TO WALLS OR CEILINGS. 14) NO SMOKE DETECTOR SHALL BE LOCATED CLOSER THAN 36" TO ANY AIR REGISTER OR DIFFUSER. 15) NO HE:AT DETECTOR SHALL BE LOCATED CLOSER THAN 24" TO ANY AIR REGISTER OR DIFFUSER. 16) NO HEAT DETECTOR SHALL BE LOCATED CLOSER THAN 36" TO ANY PART OF ANY HEAT GENERATING DEVICE (FUSES, BOILERS, WATER HEATERS, ECT.) IN MECHANICAL ROOMS. 17) NO HE:AT DETECTOR SHALL BE LOCATED CLOSER THAN 18" TO ANY PART OF ANY LIGHT FIXTURE. 18) INITIATING AND SIGNALING CIRCUITS ARE SEPARATE YET MAY BE RUN IN SAME CONDUIT. 19) ALL CONDUCTORS SHALL BE LABELED BY ZONE AND ALL COLOR CODES SHALL MATCH. 20) THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS, THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA. ALL WIRING AND INSTALLATION METHODS SHALL BE IN COMPLIANCE WITH CURRENT RELEVENT NATIONAL ELECTRICAL CODE ARTICLES AND RELATED SECTION CODE REQUIREMENTS. WIRING INSTALLATION NOTES: * LABEL ALL ZONE WIRES WfTH ZONE NUMBER TAG AND DESCRIPTION. * LABEL ALL SIGNAL CIRCUIT WIRES WITH SIGNAL CIRCUIT NUMBER TAG AND DESCRIPTION. * LABEL ALL NETWORK, ANNUNCIATOR AND I/O CONTROL CIRCUIT WIRING WITH CIRCUIT NUMBER TAG AND DESCRIPTION. Letter•r.ify This document and the information/depictions contained/shown. is the exclusive property of Convergint Technologies LLC and shall be handled as proprietary and confidential information and must be returned upon request. This document cannot be reproduced by any means without the written authorization of Convergint Technologies LLC. Color/Type Sze Function A 2.. Black / Orange TFN 16 Zone B • 4 Black / Orange TFN 16 Zone Loop C 2 Red / Blue THHN 14 Horn / Strobe D 4 Red / Blue THHN 14 Hom / Strobe Loop E 2 •Brown / Yellow THHN 14 Door Control F 2 Orange THHN 14 Fan Shutdown G 18 Black TFN 16 Graphic Annunciator H 1 • Twisted / Shielded Pair , 18 Serial Communication 2 Red / Black 14 24VDC Power I 1 Twisted / Shielded Pair 16 Audio Riser J 1 Twisted 16 Speaker K 2 Twisted 16 Speaker Loop L • 2 Yellow THHN 14 Elevator Control M N 1 WestPenn D975 18 Network Communication 0 P 2 Red / Black THHN 14 24VDC Power Q ---- R 2 Blue / White TFN 16 Remote LED w/ test 2 Pink TFN 16 Remote LED w/ test S 2 Red / Yellow 16 Signature Data Line T 2 Purple / Yellow THHN 14 Dialer U 2 Red / Black THHN 14 Suppresion Solenoid V 2 Black / Yellow TFN 16 • Vesda Reset W X 1 62.5 Multimode Fiber Network Communication Y 5 Orange THHN 14 Fan Control Z 2 Purple / White THHN 14 Smoke/Fire Dampers SHEET NO. FA -0.0 FA -0.1 FA -1.0 DRAWING INDEX INCLUDED IN 1111S KOUT X TITLE, INDEX, LEGEND X SCHEDULES X PARTIAL 4TH FLOOR PRE—ACT1ON FLOOR PLAN & DETAILS fUKWILA FIRE DEPARTMEN1 Please call: 575-440Z and give this job No. 't -F- r and exact address for shut' down or restoration approvaP Cot , T E C - , • • 6 1E S 450 Shattuck Avenue South, Renton, Washington 98055 Phone: 425-272-2250 Fax: 425-251-0949 This document and the information/depictions contained/shown. is the exclusive property of Convergint Technologies LLC and shall be handled as proprietary and confidential information and must be returned upon request. This document cannot be reproduced by any means without the written authorization of Convergint Technologies LLC. .ii IC O . CCEPTi'", it Without Comments fJ As Noted In Red Per The Attached Letter • These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the de -signer. Additions, deletions or revisions to these drawings after this date will void this,acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: X/01-3/0 Y By: A1/t1 V ( 111162[0.1.11MISIMMIttliMilammanssaumstosommeorsassmmteamoonemempow, DESCRIPTION ISSUED FOR PERMIT APPROVED 8-12-04 NOTICE A completed, signed. To foNill- riro Department Pre-tc—t presented to t' • correrneneemk!n( •!;.--,c7,1,:g cf. IA arm and Detection Systems. it re of test will result in $80 Re- Insoetion Fee and termination of the testing. DRAWN BY: JDB PROJECT ENGINEER: JDB PROJECT MANAGER: JOB NUMBER: 301 -FN -4148 SCALE: NTS DATE: DEPARTMENT OF HOMELAND SECURITIES BUILDING 12500 TUKWILA INTERNATIONAL BLVD. TUKWILA, WA 98168 TITLE,INDEX,LEGEND PRE -ACTION SYSTEM 1- 450 Shattuck Avenue South, Renton, Washington 98055 Phone: 425-272-2250 Fax: 425-251-0949 This document and the information/depictions: contained/shown is the exclusive property of Convergint Technologies LLC and shall be handled as proprietary and confidential information and must be returned upon request. This document cannot be reproduced by any means without the written authorization of Convergint Technologies LLC. BATTERY CALCULATION - SCP BATTERY CALCULATION - APS Qty Part Number Description Standby Total Alarm Total Current (A) Standby (A) Current (A) Alarm (A) Suppression Control Panel 0.1990 0.1990 0.2350 0.2350 Qty Part Number Description Standby Total Current (A) Standby (A) 1 SIGA-APS Auxiliary Power Supply 1 SIGA-REL Solenoid Releasing Module 1 VICTAULIC #753-E Suppression Solenoid 0.0610 0.0250 0.0000 0.0610 0.0250 0.0000 Alarm Total Current (A) Alarm (A) 0.0610 0.1700 0.3640 0.0610 0.1700 0.3640 Total Standby= 0.1990 Total Alarm= 0.2350 Total Standby Current Required= 0.1990 Total Alarm Current Required= 0.2350 Total= 20% Depletion Factor - Total Amp/Hour Required= Total Amp/Hour Batteries Provided= Time (Hrs) 24.0000 4.7760 0.0833 0.0196 4.7956 0.9591 5.7547 (1) set 7.5000 Total Standby= 0.0860 Total Alarm= 0.5950 Total Standby Current Required= 0.0860 Total Alarm Current Required= 0.5950 Total= 20% Depletion Factor - Total Amp/Hour Required= Total Amp/Hour Batteries Provided= Time (Hrs) 90.0000 7.7400 0.1666 0.0991 7.8391 1.5678 9.4070 (1) set 10.0000 DESCRIPTION ISSUED FOR PERMIT APPROVED 8-12-04 DRAWN BY: JDB PROJECT ENGINEER: JDB PROJECT MANAGER: JOB NUMBER: 30I -FN -4148 SCALE: NTS DATE: DEPARTMENT OF HOMELAND SECURITIES BUILDING 12500 TUKWILA INTERNATIONAL BLVD. TUKWILA, WA 98168 SCHEDULES PRE -ACTION SYSTEM f?TTT-I-I-1—i'7Tf n 120 VAC WUAPfR POWER Io1__L—LLLIA ADDRESS ? $a 242 SIGA—APS �J RELEASING MODULE IMIMMMEM 184 1 2 3 4 —+ —+ TEM 234 — + — + DATA IN (—) DATA IN (+) FROM SIGNATURE CONTROLLER OR PREVIOUS DEVICE RELEASE CIRCUIT 1 450 Shattuck Avenue South, Renton, Washington 98055 Phone: 425-272-2250 Fax: 425-251-0949 This document and the information/depictions contained/shown is the exclusive property of Convergint Technologies LLC and shall be handled as proprietary and confidential information and must be returned upon request. This document cannot be reproduced by any means without the written authorization of Convergint Technologies LLC. APS POWER SUPPLY RELEASING MODULE TYPICAL N.O. INITIATING DEVICE INITIATING DEVICE UL/ULC USTED 47KD EOL TYPICAL N.O. A INITIATING DEVICE DESCRIPTION NOT USED DATA IN/OUT (+) NOT USED DATA IN (—) REMOTE LED REMOTE LID NOT USED DATA OUT (—) \RE: TO FLOOR PLANS: P MAY BE LOCATED WITHIN THE OTECTED SPACE RATHER THAN AT E SPRINKLER RISER r DATA IN (+) DATA IN_(-) FROM SIGNATURE ONTROLLER OR PREVIOUS DEVICE DATA IN ((—) FATA RROOM SIIGNA)TURE ONTROLLER OR PREVIOUS DEVICE DATA OUT (—) DATA OUT (+) TO NEXT DEVICE SINGLE INPUT MONITOR MODULE DUAL INPUT MONITOR MODULE SMOKE DETECTOR BASE SUPPRESSION CONTROL PANEL EOL Q A EOL OIN 1 ll > 120 VAC 120 VAC PRE—ACTION RELEASE MODULE DESCRIPTION ISSUED FOR PERMIT APPROVED 8-12-04 RISER DATIAL 4TH PLA\ Scale: 1/4" = 1'-0" DRAWN BY: JDB PROJECT ENGINEER: JDB PROJECT MANAGER: JOB NUMBER: 301 -FN -4148 SCALE: 1/4" = i'-0" DATE: I 1 , _T r ii , L.J--JI i ---- ____ _______ —_-'_____-I A I --M '1 I ......r i 1._ 1 ,f -,_, L. T I i ( (L. jj-_ , �s I ® s , 4 , i 1 -----.'N to ' III __ EOL Q A EOL OIN 1 ll > 120 VAC 120 VAC PRE—ACTION RELEASE MODULE DESCRIPTION ISSUED FOR PERMIT APPROVED 8-12-04 RISER DATIAL 4TH PLA\ Scale: 1/4" = 1'-0" DRAWN BY: JDB PROJECT ENGINEER: JDB PROJECT MANAGER: JOB NUMBER: 301 -FN -4148 SCALE: 1/4" = i'-0" DATE: DEPARTMENT OF HOMELAND SECURITIES BUILDING 12500 TUKWILA INTERNATIONAL BLVD. TUKWILA, WA 98168 PARTIAL 4TH FLOOR SERVER ROOM PRE -ACTION FLOOR PLAN & DETAILS PRE -ACTION SYSTEM ALL RIGHTS RESERVED. BY PRECISION M CDO N = _O 82 >- C) O U 23—Dec-2003 CLI O Symbols Legend Symbol QTY Description Mounting Manufacturer Part # 2 16 AWG TFFN Fire Rated (in EMT) 1 Intelligent Fire Alarm System Control Panel SBB-04 Enclosure at 72" to Top Notifier NFS-640 FACP Red Jacket Fire Cable tag for ckt type Duct Detector Interconnect ibata (SLC) Circuit 1 Voice Evacuation Control Panel SBB-03B Enclosure at 72" to Top Notifier Transponder VECP G 2 16 AWG TFFN Fire Rated (in EMT) 1 Graphic Annunciator Semi Flush at 66" to Top Kirkland CEF-L-GR-GP3 GANN] Red Jacket Fire Cable tag for ckt type Aux Relay Interface Plenum H Intelligent Photo Smoke Detector 4 Square Deep w/ 3" Round Ring Notifier FSP -851 w/ B7101p Base J 2 14 AWG THHN Fire Rated (in EMT) Intelligent Heat Detector 4 Square Deep w/ 3" Round Ring Notifier FST -851 w/ B7101p Base 24 Intelligent Manual Pull Station 1 Gang at 48" to Top Notifier NBG-12LX F 2 14 AWG THHN Fire Rated (in EMT) 2 14 AWG THHN Fire Rated (in EMT) -- 54 Intelligent Duct Smoke Detector with Relay Surface (Ref. Mfg Information) Notifier FSD-751RP West Penn 60993 54 Duct Detector Remote Indicator with Test Switch 1 Gang at Ceiling or at 80" to Center on Wall Notifier RTS -451 RT Resettable Aux Power Circuit R 5 Intelligent Monitor Module 4 Square Deep Notifier FMM-1 M S 1 pair 14 AWG Fire Rated Cable (FPL)_ 17 Intelligent Monitor Module Dual Circuit 4 Square Deep Notifier FDM-1 DM Red Jacket Fire Cable tag for ckt type _Strobe Strobe (NAC) Circuit Plenum 6 Intelligent Relay Module 4 Square Deep Notifier FRM-1 IR 2 14 AWG THHN Fire Rated (in EMT) U 21 Intelligent NAC Control Module SBB Back Box supplied by PA Notifier FCM-1 IC West Penn 60993 QQ 10 Shunt Trip Conventional 135 degree Heat Detector 4 Square Deep with 3" Round Ring Edwards 283B NAC Sync Circuit Riser 5 End of Line Power Supervision 4 Square Deep Notifier FMM-101 with A77-716 Relay EOLR _West 1 pair 14 AWG Twisted Shielded Fire Rated Cable (FPL) V 19 Remote Relay L Surface Notifier MR -201C R 5 Audible Power Supply Surface Notifier FCPS-24S6 APS Y 2 ea 1 pair 16 AWG Twisted UnShielded Fire Rated Cable (FPL) 5 Strobe 30 cd 1 Gang at 80" to Bottom Notifier S2430W 3 Red Jacket Fire Cable tag for ckt type ®c 14 CEILING Strobe 15cd 4 Square Deep Notifier SC2415W 0c 2 CEILING Strobe 30cd 4 Square Deep Notifier SC2430W (Dc 33 CEILING Strobe 95cd 4 Square Deep Notifier SC2495W Eli 2 Speaker / Strobe 30cd 4 Square Deep at 80" to Bottom Notifier SP2W2430 DI 7 Speaker / Strobe 75cd 4 Square Deep at 80" to Bottom Notifier SP2W2475 ED4 28 Speaker / Strobe 110cd 4 Square Deep at 80" to Bottom Notifier SP2W24110 F c 5 Ceiling Speaker 4 Square Deep Notifier SP200W DIc 26 CEILING Speaker / Strobe 15cd 4 Square Deep Notifier SP2C2415 3 c 2 CEILING Speaker / Strobe 30cd 4 Square Deep Notifier SP2C2430 Di 1 CEILING Speaker / Strobe 75cd 4 Square Deep Notifier SP2C2475 Is Fire Alarm Cable Routed in Metallic Raceway Supplied by Others Q Fire Alarm System "J" Box Sized for Conductor Fill Supplied by Others 2 Motorized damper Supplied by Others MD O 17 Motorized Smoke Fire Damper Supplied by Others OR 18 Motorized Return Air Damper Supplied by Others (Ds 17 Motorized Supply Air Damper Supplied by Others FB ® 6 feedback switch for fan running' indication Supplied by Others ® 8 Fire Sprinkler Waterflow Switch Supplied by Others ® 17 Fire Sprinkler Tamper Switch Supplied by Others 0 1 Fire Sprinkler PIV Switch Supplied by Others 3 Fire Sprinkler Dry System Alarm Pressure Switch Supplied by Others ® 3 Fire Sprinkler Dry System High - Low Pressure Switch - Supplied by Others Note. device shown for identification only Existing Devices in Gray Scale Flag Notes 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 Route Cable To Fire Alarm J Box on Lower Level Route Cable To Fire Alarm J Box Upper Level Route Cable to Elevator Controller for Primary Recall Route Cable to Elevator Controller for Alternate Recall Route cable to connection for elevator controller fife hat Reference Connection Details for Wiring Interface monitoring for damper position switches Route Conductors to HVAC Fan Shutdown Interface Route Switch Leg to Damper Circuit Breaker for Damper Activation Route Switch Leg to Return Air Damper Circuit Breaker Route Switch Leg to Supply Air Damper Circuit Breaker Cable for Elevator Cab Speaker and is Routed to Cab via Elevator Traveling Cable. Gutter Mounted Over FACP, VECP Route Cable to Pressurization Fan Starter Contacts Non System Heat Detector for Elevator Shunt Trip Only, Mount Within 18" of Sprinkler Head Locate EOLP in back box for FCM-1 Control module for APS circuits 1 & 2 Control module for APS circuits 3 & 4 Route Conductors to Exhaust Fan Shutdown Interface Route cable to voice riser in South Stair Route Cable to gutter over Voice Panel Proper supervision will require feed and return wiring for all elevator cab speakers except the EOL RF -1 and RF -2 start and motorized dampers operate only on activation of manual damper switch on graphic AC unit shutdown Sheet Note 1 Tap all Speakers at 1/4 Watt 25 Volts 2 Ambient 45dba as Listed in NFPA 72 A-4-3.2 All Audible Devices are set for 96 dba at 10' 3 Ambient Temperature is Between 65 and 80 degrees Riser Note 1 Do Not Route Conduit Into the Bottom of Any Fire Alarm System Component Cabinets - Use Factory Knockouts only \ ' • Wire Legend Symbol Description MFG. Part Number Color Coded Cable Type of Circuit Application A 2 16 AWG TFFN Fire Rated (in EMT) Parking Level 2 FA -3 Conventional (IDC) Circuit B 2 16 AWG TFFN Fire Rated (in EMT) 1 pair 16 AWG Twisted NON Shielded Fire Rated Cable (FPL) West Penn 0990 Red Jacket Fire Cable tag for ckt type Duct Detector Interconnect ibata (SLC) Circuit D D 1 pair 16 AWG Twisted NON Shielded Fire Rated Cable (FPLP) West Penn 60991 Red Jacket Fire Cable tag for ckt type Data (SLC) Circuit Plenum G 2 16 AWG TFFN Fire Rated (in EMT) Graphic Annunciator Aux Relay Interface G 1 pair 16 AWG Fire Rated Cable (FPLP) West Penn 60991B Red Jacket Fire Cable tag for ckt type Aux Relay Interface Plenum H 2 16 AWG TFFN Fire Rated (in EMT) Remote Indicator Circuit J 2 14 AWG THHN Fire Rated (in EMT) _ HVAC Interface K 2 14 AWG THHN Fire Rated (in EMT) _Damper Interface -Aux Interface L 2 16 AWG TFFN Fire Rated (in EMT) M 2 14 AWG THHN Fire Rated (in EMT) 2 14 AWG THHN Fire Rated (in EMT) Door Holder Circuit Aux Power Circuit P P 1 pair 14 AWG Fire Rated Cable (FPLP) West Penn 60993 Red Jacket Fire Cable tag for ckt type Aux Power Circuit Plenum R 2 14 AWG THHN Fire Rated (in EMT) Resettable Aux Power Circuit R 1 pair 14 AWG Fire Rated Cable (FPLP) West Penn 60993 Red Jacket Fire Cable tag for ckt type Resettable Aux Power Circuit Plenum Strobe (NAC) Circuit S 2 14 AWG THHN Fire Rated (in EMT) S 1 pair 14 AWG Fire Rated Cable (FPL)_ West Penn 972 Red Jacket Fire Cable tag for ckt type (NAC) Circuit S 1 pair 14 AWG Fire Rated Cable (FPLP) West Penn 60993 Red Jacket Fire Cable tag for ckt type _Strobe Strobe (NAC) Circuit Plenum T 2 pair 24 AWG Telephone Cable '- Telephone Circuit NAC Sync Circuit U 2 14 AWG THHN Fire Rated (in EMT) U 1 pair 14 AWG Fire Rated Cable (FPL) West Penn 972 Red Jacket Fire Cable tag for ckt type NAC Sync Circuit U 1 pair 14 AWG Fire Rated Cable (FPLP) West Penn 60993 Red Jacket Fire Cable tag for ckt type NAC Sync Circuit Plenum U 1 pair 14 AWG Fire Rated Cable (FPLR) West Penn 994 Red Jacket Fire Cable tag for ckt type NAC Sync Circuit Riser U 1 pair 14 AWG Fire Rated Cable (Wet Location) Penn AQ226 West Penn D995 Red Jacket Fire Cable tag for ckt type Red Jacket Fire Cable tag for ckt type NAC Sync Circuit Wet Location Speaker (NAC) Circuit V _West 1 pair 14 AWG Twisted Shielded Fire Rated Cable (FPL) V 1 pair 11 AWG Twisted Shielded Fire Rated Cable (FPLP) West Penn 60992 Red Jacket Fire Cable tag for ckt type Speaker (NAC) Circuit Plenum W 5 16 AWG TFFN Fire Rated (in EMT) Remote Test Station Circuit X 3 Cond 18 AWG Twisted Shielded Cable West Penn D303 Remote Printer Cable Y 2 ea 1 pair 16 AWG Twisted UnShielded Fire Rated Cable (FPL) Belden 9572 Red Jacket Fire Cable tag for ckt type (LAN) Panel Network Circuit Z 1 pair 14 AWG Twisted Shielded Fire Rated Cable (FPLR) West Penn 995 Red Jacket Fire Cable tag for ckt type Audio Riser Buss Wire Manufacturer is for Reference Purpose Only NOTE. (Y) Type Cable Max length 1,000 ft. between Panels GENERAL NOTES 1. INSTALLATION SHALL BE ACCOMPLISHED IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE AHJ'S, NEC, AND CONTRACT DRAWINGS. 2. WIRE ROUTING IS DIAGRAMMATIC IN NATURE ONLY AND NOT INTENDED FOR ACTUAL CONDUIT ROUTING. 3. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ. 4. THE SYSTEM SHALL BE MONITORED BY A UL LISTED MONITORING STATION BEFORE AHJ TEST. 5. VERIFY ALL LOCATIONS OF DEVICES WITH ELECTRICAL/ARCHITECTURAL PLANS. SCALE AND PLACE ALL DEVICES PER ELECTRICAL/ARCHITECTURAL PLANS. 6. FIELD VERIFY WATER FLOW, SPRINKLER, SMOKE DAMPERS AND DUCT DETECTOR LOCATIONS. 7. FIELD VERIFY ALL WIRING LOCATIONS AND REQUIREMENTS FOR HVAC AND FAN CONTROL. 8. SMOKE DETECTORS SHALL NOT BE LOCATED WITHIN 3'-0" OF AIR DIFFUSERS. 9. NFPA 5-3.6.1.3 REQUIRES THAT NO SMOKE DETECTORS ARE TO BE INSTALLED UNTIL AFTER FINAL CONSTRUCTION CLEAN-UP. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO CLEAN-UP MUST BE CLEANED OR REPLACED ACCORDING TO CHAPTER 7 AND WILL BE INVOICED ON A T&M BASIS. 10. FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF TECHNICIANS. 11. ALL CIRCUITS WILL BE PROPERLY TAGGED AND TESTED FOR OPENS, SHORTS, GROUNDS AND PROPER END OF THE LINE RESISTANCE. EACH CIRCUITS METER READING MUST BE DOCUMENTED AND PRESENTED TO FIELD TECHNICIAN UPON ARRIVAL ON SITE FOR CHECKOUT. 12. A SET OF INSTALLATION AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY FIELD TECHNICIANS. 13. AGREEMENT AND CONFIRMATION OF ALL MILESTONE EVENTS WILL BE MADE WITH PROJECT MANAGER. SERVICES MUST BE SCHEDULED WITH PROJECT MANAGER WITH A MINIMUM OF TEN WORKING DAYS NOTICE. 14. NO TAPPING OF SIGNALING OR INITIATING ZONE CIRCUITS ARE ALLOWED. T -TAPPING OF STYLE 4 ADDRESSABLE CIRCUITS IS ALLOWED PROVIDING SPLICE IS PROFESSIONALLY INSTALLED, POLARITY IS OBSERVED, SHIELDS ARE CONTINUOUS AND FREE OF GROUNDS. SHIELDS SHALL BE TERMINATED AT FACP ONLY. "CABLE SHIELDS SHALL BE SPLICED TOGETHER AT EVERY JUNCTION BETWEEN THE FIRE ALARM PANEL AND THE LAST DEVICE ON EACH CABLE RUN. SHIELDS AND OTHER FIRE ALARM CONDUCTORS (EXCEPT POWER GROUNDS) SHALL BE INSULATED AND COMPLETELY FREE FROM CONDUIT OR EARTH GROUNDS. SHIELDS WILL BE TIED TO GROUND ONLY AT THE FIRE ALARM PANEL BY THE INSTALLING FIRE ALARM TECHNICIAN." 15. MOUNT AUDIBLE/VISUAL DEVICE BACKBOX AT 80" TO BOTTOM AFF OR 6" BELOW CEILING WHICH EVER IS LOWER. SEE FLOOR PLANS FOR CANDELA RATING OF DEVICE BEING INSTALLED. 16. AS BUILTS ARE REQUIRED AT TIME OF AHJ ACCEPTANCE. PRECISION ALARM NEEDS RED LINE AS BUILTS 2 WEEKS PRIOR TO AHJ TESTS. 17. NO LINE VOLTAGE IN CONDUIT WITH FIRE ALARM WIRE. Sheet Schedule Sheet Number Description FA -0 cover sheet FA -1 Parking Level 3 FA -2 Parking Level 2 FA -3 Parking Level 1 FA -4 1st Floor Plan FA -5 2nd Floor Plan FA -6 3rd Floor Plan FA -7 4th Floor Plan FA -8 Roof Plan FA -9 Riser FA -10 Graphic Annunciator ACCEPTED Without Comments As Noted In Red 0 Per The Attached Letter These plans have been reviewed by The Tukwila Fire Preve: t. • : 3u • aU for conformance ance with current city st ;n:: -. • . is subject to errors and orr: w . :,; ,r; do not authorize violations of adopted st. ;c. ;d ordinances. The responsibility for the aci::. • , deesign rests totally with the designer. I :_ . :s, ;.;aletions or i visions t these drawings after this c:.1.E1-1-; ii void this:acca:itance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: i v/ 15(7 By: 3j�'�/1� / goy 2/ rUKWILA FIRE DEPARTMENT_ Please call: 575-4407 and give this job 0/ and exact address for smut - dawn or restoration apNruvah tn 0z V? DESCRIPTION O z 4100 Aldorwood Mall Blvd, Suite 3 Lynnwood, Wa. 98036 FAX (425) .697-2155 TEL (425) 697-2116 W 0 0 1 0 cc 1 6 W J 1- W >111 2 0 W 0) z J w 0 1 WASHINGTON 1 C SCALE: AS NOTED PROJECT NUMBER: 1239 DRAWN BY: DME DESIGNED BY: JMC CHECKED BY: INITIALS F:7 1 L EE: DATE: 8/20/03 SHEET JAN 1 6 2004 FA_,/ -0 wteittesof5 c!1re-6/ /23t1 J J U J J z 0, U ce 0 1 SEE ENLARGED STAIR PLAN ON DETAIL 2/A1.7 MODULAR BLOCK WALL. SEE CIVIL PRECAST CONCRETE AROUND DOOR OPENING. SEE ELEVATIONS. PLANTER WP4 AT WALLS OF EXIT TUNNEL 1 Y" STEEL PIPE RAILING (PAINTED) AT 2'-10" ABOVE RAMP AND LANDING SURFACE. EXTEND 1'-0" BEYOND TOP & BOTTOM OF RAMP AND RETURN TO WALL. PLANTER PLANTER LANDSCAPE • 88 90 92 FROST PROOF HOSE BIBB .1111\J �i�,\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\` 94 �B 1611111\1, `l'� ins \\ 111 86.4 TRASH COMPACTOR BY OWNER7 86.4 SEE ENLARGED RAMP/STAIR PLAN ON SHEET A 1.13 87 87 LOADING DOCK • S,V 87 86.4 LANDSCAPE /t/ • 88 90 CONCRETE CURB 92 94 LANDSCAPE PLANTER MODULAR BLOCK WALL. SEE CIVIL PRECAST CONCRETE AROUND DOOR OPENING. SEE ELEVATIONS. :4141,-1��11 1 1 11 t hs ii h V1 ih r,t. 47 !i liv) 41 \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ \\\\\\\\\\\\\\\\\\\\ 48" x 48" COM"ACTOR SHUTE IN WALL — VERIFY SIZE AND LOCATION IN i N1-3 2S,2V V-1 o F.D. RECEIVING EL. 91.0 • 12" CONCRE WALL EL. 91.0 b\N 1 1•i ,3l 11 I I I II II III 4•iii♦21.ii,•iiii;•,AN♦i •ii+�,` N1- Iv—CORRIDOR 44 C UP STAIR #2 • 1 S,2V WALL 1004 FURRING WITH INSULATION,\\\I FULL HEIGHT AT G' E/ G V " D SIDE D 42111irnballt •■ ■ ■ • • 1002 D • • ■ �,■ • `III, • ■ • ■ II' •■ ■ ■ • • ■ ■ • ■ ••■ "• o I • 10 'ib■ ■ • • • \ \\\\\\� ``. "WE\ \\\\\\\\\\\\\\\` 0 EDGE OF 8" CONCRETE WALL BELOW D,2S,2V ELECT. D,2S,V A I►�1 I� A 74•74!i i!•AA!Qw.!•S!•!•AAaTeie• !i!' • ••!'••i!i•••••••iii iNU!Jo'!w$•LA♦!•!O♦: W V) LU PRECISION ALARM, L.L.C. ALL RIGHTS 4 ---�\\\\\\\\\\\\\\ig1M.\\\\\\\\\\\\\\\\\\\\\\\\\\\\\y \\\\\\\\\\\\\\\\\\\\\ \\\1 NEI \\` \\\\\\\\\\\\\\\\\\\\\\\1LI \` MAIN LINK FENCING IN OPENING. (2'-0" HIGH x 22'-0" WIDE) CHAIN LINK FENCING IN OPENING. (2'-C" HIGH x 22'-0" WIDE) PAINTED STRIPING SLOPE 18" CONC. COLUMN 4N2-1 V-2 2S 2V of 4444\\\4\4\4\4444\\4 STORAG 2S,2V V 1 m W DESCRIPTION Q 0 z i 4100 Alderwood Mail Blvd, Suite 3 Lynnwood, Wa. 98036 FAX (425) 697-2155 TEL. (425) 697-2116 P207 MANAGER STORAGE N2-2 S,2V 1009 _ \\\\ `\�\\\\\\\\\S D,S,2V PARKING EXHAUST FAN WITH SHAFT TO DAYLIGHT ABOVE. SEE MECHANICAL DRAWINGS. 8" CONCRETE SHAFT WAL STRUCTURAL. 61Mlimik'l ST \\\\\\\\\\\\\\\\\\\\\\► Libl\\\\\\\\\\\\\\\\\\ Flag Notes Route Cable To Fire Alarm J Box on Lower L$ve1 Route Cable To Fire Alarm_) Box Upper Lev Route Cable to Elevator Coltroller for P- y Recall Route Cable to Elevator Coitroller for Alternate Recall Route cable to connection for elevator controller fire hat Reference Co-nection Details for Wiring Interface monitoring fpr damper position switches Route Conductors to HVAC Fan Shutdown Interface Route Switch Leg to Damper Circuit Breaker fon Damper Activation Route Switch Leg to Return Air Damper Ci,cuit Breaker Route Switch Leg to Supply Air Damper Ci'cuit Breaker Cable for Elevator Cab Speaker and is Routkd to Cab via Elevator Traveling Cable. Gutter Mounted Over FACP, VECP Route Cable to Pressurization Fan Starter ontacts Non System Heat Detector for Elevator Shun Trip Only, Mount Within 18" of Sprinkler Head Locate EOLP in back box for FCM-1 Control module for APS circuits 1 & 2 Control module for APS circuits 3 & 4 Route Conductors to Exhaust Fan Shutdown I terface Route cable to voice riser in South Stair 9'-0" DIAMETER CORRUGATED METAL PIPE TO CONCRETE SHAFT PER STRUCTURAL DRAWINGS. 8" dONCRETE SHAFT WALLS PER STR CTURAL. EXH UST FAN WITH SHAFT TO DAY IGHT ABOVE. SEE MECHANICAL DRA INGS. 22 Proper supervision will require feed and return wiring for all elevator cab speakers except the EOL 23 RF -1 and RF -2 start and motorized dampers operate only on activation of manual damper switch on grap ADDRESS MOD 1007-1009 DET 1005-1006 V-2 P2 VOICE CIRCUIT 23—Dec-2003 PLOT DATE: 2 2 2 e) P-2 PARKING PLAN eSCALE: 1/B; = 1'-0" W LL z LL, o 0(D I- _ Q cn cc 3 r� LLJ W Cn J o 1'- m W Q z CrI- z LLJ 3 z Q H WQ U) I -I Z 1-- ao J W 0 1 r SCALE: AS NOTED PROJECT NUMBER: 1239 DRAWN BY: DME DESIGNED BY: JMC CHECKED BY: INITIALS DATE: 8/20/03 j SHEET FA -2 RESERVED. BY PRECIS \\\\\\\\\\\\\\\\\\\\\\\\NE \`\\\ PAINTED STRIPING CONC. COLUMN HEAT TA MONITOR t III fp 1 x:;31 DN. UP TAIR ; 2 16 17 ARE P MONIT ■<ZZ!!mil N\\\\\\ill \I M 1E1� 1018 kIIME \�'MMEl 0��►1��� 101 s D,S,V 11111111011 N2-3 V-3 2S 2V N2-4 V-3 47K .� II1008 D STO ,` ELEV. RAGE ,` 11 .13 r. ELEV. D,P,2S,2V STORAGE co W ec /1 Route Coble To DESCRIPTION Alarm J Box on Lower Level DATE 0 z 'Route Cable To Pout — •le to Pout J e to Route le to eference Connection onitoring for Route Conducto^s Route Switch Leg Route Switch Leg Fire Elevator Elevator connection damper to to to Alarm J Box Lpper Controller Controller for elevator Details for position switches HVAC Fan Shutdown Damper Circuit Return Air Damper Level for Primary for Alternate controller Wiring Interface Interface Breaker for Circuit Breaker FAX (425) 697-2155 TEL. (425) 697-2116 , 10 EDLP�:�.®. 114 `.•:w..7•wBOP.1-er7•A:C.!i•: amu: 1 _' r D,P,2S,2 TOR BY 008 D,P,2S,2 D,P,S,2V ELEV. -X� UP DN. STAIR D,P,2S,2 D,P,S,2V D,P,S,2V V 3 4 PARKING P101) GWB PIPE ENCLOSURE AT UNDERSIDE OF PT DECK ABOVE. CLOSET ER, PUMPER TION AND IC WATER SEE ICAL PLAN. 47K vv. zfre ta► ii% 1 :�=, 4 g rt ICAL GMN=Wirs' u' , IC.T DOWN 1.11f►\mw \\ \`\ \\ lia 11111 16 MEIN \. . EXHAUST FAN WITH SHAFT TO DAYLIGHT ABOVE. SEE MECHAN DRAWINGS. 8" CONCRETE SHAFT WALLS PER STRUCTURAL IN U ELEVATOR CAB •:■ DIAMETER ATED METAL CONCRETE ER URAL S. O N U N N PLOT DATE: ADDRESS MOD 1010-1031,1114-1115 DET 1007-1011 V-2 P1 VOICE CIRCUIT V-4 ELEV VOICE CIRCUIT Flag Notes /1 Route Coble To Fc Alarm J Box on Lower Level 2 7 8 'Route Cable To Pout — •le to Pout J e to Route le to eference Connection onitoring for Route Conducto^s Route Switch Leg Route Switch Leg Fire Elevator Elevator connection damper to to to Alarm J Box Lpper Controller Controller for elevator Details for position switches HVAC Fan Shutdown Damper Circuit Return Air Damper Level for Primary for Alternate controller Wiring Interface Interface Breaker for Circuit Breaker Recall Recall fire hat Damper Activation C bute Switch Leg to Supply Air Damper Circuit Breaker 1 .;able for Elevator . Lab speaker and is Houten to Gab via Elevator traveling Cable. - -- - -- -- 14 Route Cable to Pressurization 15 Non System Heat Detector .r FACP, VECP Fan Starter Contacts for Elevator Shunt Trip Only, Mount Within 18" of Sprinkler Head 16 Locate EOLP in bee,< box for FCM-1 \\ 17 Control module for APS circuits 1 & 2 18 Control module for APS circuits 3 & 4 \\\\\\\\\\ \ 10 Routc Conductor \\o Exhaust Fan Shutdown Interface \ \\2b.\\R EQ&a/11)st\t.h\ 21 Route Cable to 22 Proper supervision gutter r2ris`fkr\ i\4iOth\.tic\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ over Voice Panel will require feed and return wiring for all elevator cab speakers except the EOL 23 RF -1 and RF -2 start 24 25 26 27 and motorized dampers operate only on activation of manual damper switch on graphic SHAFT BELOW. SEE P-1 & P-2 PARKING LEVEL PLANS. EXHAUST FAN WITH SHAFT DAYLIGHT ABOVE. SEE M DRAWINGS. HANICAL la Eli FFAMEILWEE1.\\WEIW\WitifilM\1\ EE �!I\ \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\`` LIJ J F -- F -- <a: cnW .J on Q z O z CC LLJH J 3 I-- CD 0 LC) �-1 2e), P-1 PARKING PLAN a0 SCALE: 7/8" = r SCALE: AS NOTED PROJECT NUMBER: 1239 DRAWN BY: DME DESIGNED BY: JMC CHECKED BY: INITIALS DATE: 8/20/03 j SHEET FA -3 J -J • LOUVER LOUVER SALLY PORT S-3 OCCUPANCY AS T.I. iillhiiiJiI1 STAIR #4 N3-2 V-5 1019 OPEN OFFICE OPEN OFFICE SHEAR WALL 1° Nvki 1018 D,P,2S,2 1023 TOR BY ,P,2S,2 REV. BY: s W1C1 b (->—n „LLJ L) 1095,1 ;gip p ; 2A,D3 DESCRIPTION RT kj W 4 C O Z 4100 Aldorwood Mali Blvd, Salto 3 Lynnwood, Wa. 98036 FAX (425) 697-2155 TEL. (425) 697-2116 DN. UP STAIR :'2 D / 46&41 ii iRl I i; 1043 V-5 2A,D,P,2V 2A,D P,2V OPEN o—D,P 2A --a s W1C1 b (->—n „LLJ L) 1095,1 ;gip p ; 2A,D3 � \ RT kj OPEN o—D,P 2A --a u R (->—n „LLJ L) 1095,1 ;gip p ......•, LOBBY Route Cable To Fire Route Cable To Fire arm J Box on Lower Level larm J Box Upper Level Route Cable to Elev R q cable to co Reference Connect' or Controller for Alter t'on for elevator co tr Q tails for Wiring Ii� ler fire hat ace NOTE: 3 DAMPER POWER CIRCUITS ARE REQUIRED A. SUPPLY AIR DAMPERS B. RETURN AIR DAMPERS C. FIRE SMOKE DAMPERS DAMPERS MUST HAVE TWO POSITION SWITCHES. ONE N/C THAT OPENS WHEN THE DAMPER IS OPENED. ONE THAT CLOSES WHEN THE DAMPER IS CLOSED. --4--/—/-ak TYPICAL WIRING FOR DAMPER POSITION SWITCH ADDRESS MOD 1032-1049,1095-1096 DET 1012-1045 23 O 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 Route Conductors to Route Switch Leg to Route Switch Leg to Route Switch Leg to S Cable_ for Elevator Ca p Traveling Cable. Gutter Mounted Over FACP, VECP Route Cable to Pressurization Fan Starter Contacts Non System Heat Detector for Elevator Shunt Trip Only, Mount Within 18" of Sprinkler Locate EOLP in back box for FCM-1 Control module for APS circuits 1 & 2 untrol mudule for APS circuits 3 & 4 VAC Fan Shutdown Interface amper Circuit Breaker for Damper Activation eturn Air Damper Circuit Breaker Supply Air Damper Circuit Breaker b Speaker and is Routed to Cab via Elevator Route Conductors to Exhaust Fan Shutdown Interface Route cable to voice riser in South Stair Route Cable to gutter over Voice Panel Proper supervision will require feed and return wiring for all elevator RF -1 and RF -2 start and motorized dampers operate only on activation of Head W V 1 10 0 2 1 6 w J 1 H W 1 2 0 W z J W 0 WASHINGTON LU J LU CO0 J J 0 F—I z CM W z J H 0 0 10 ri CC Q SCALE: AS NOTED 'N PROJECT NUMBER: 1239 cab speakers except the manual damper switch on EOL graphic DRAWN BY: DME FIRST FLOOR PLAN p� SCALE: 1/8" = a —o DESIGNED BY: JMC CHECKED BY: INITIALS DATE: 8/20/03 SHEET FA -4 RIGHTS RESERVED. cc U W U i N LiJ 0 .9- cn z 0 VSS! IREV. BY:I DESCRIPTION 0 z ' v O O ROOF BELOW o o J Li o 0 e o L1 0 O 7 B 8 8 $ B 9 8 0 fi { 1 L U v v i i 'i i u i u u u u u 1 lialu m N4-2 S N4-2 S 2SAA N4-1 0 2S 6 T Q9 0 OPEN © OFFICE U Q N4-3 o m CONC. SHEAR l f2,1) ., WALL o o ffe mil \\, 11 k \SI . . 1._i ii ... TEL. . 2s: v v 6 2V TELEPH• ® ® ® , ' 11 22 �N4-1 i- 7i41 LOLR_E . 1 1058-2S • I � _ 209 MEN D p 114Si:2V S4„1„„„”„„,„„ .-1049rC o- � �t� R 47KVV—.1057\ .r41) 217 0-•---- -J��' "�''� 4 N, `�� `I ' 1063 Mg - 10 , � �il N ;,� Q Q W r W. , 051 .IC R 4 •4 4 — qp I al. 21► �� , ` t 4� D ----------��----------------� I N4-1 ® ® 16R 7 �N �J �� L V. I I ELEV. I [_,, 3 111 - -�i..w..._._w._...w 1111911 21 s 2 & & a aco ELNATO R o -_,2V Ta A �'- il-AI-- \� 213 207 - — I �� ��t �1�■ I 1 D,P .....•a..a. DN. UP4 WO \I1 •... �..,- 4V ©N4-3 ELEV. ELEV. II4V- STAIR i ' SATAIR; s v '�loR ;'2 • # , 204 it 1: VM‘,‘71 N4-2 1 �' I® V t:.. 1054 r� ® i IEramumr. .. r �_1: V, i m • mu a am p...7 IN h..1 m • • • • • • •-• - ----7 1 0 tt.-9 hil 91 . i h i LI . h. 1 D,P 1 D P ' V-6 N4-3 D P D P W .. 1065 D,P ® 2A D>P S+ q Sc AIP j S. L :_rii Y 4 S S D :- • r-:-:-.-._.-.... 1047 .. ►4wJ.wailJd•TwliCwO•i!dQ�IJ..!iA!wJ.�I�A!i!� .� �CJ.AIJ-iAlJdc?iw�il. pY-�✓Alw•.A!i p' P 2A 2A 47K 1 '60 RT • cp-S,V __r.�., OS 1 i W N4-3 'rill p,'I ;,; \ : �i a , 1048 �� N4-3 cy W ,Q; : s s o /� - ,•. i 10621 •: �4 :' DR -C) . 47K �`'� �''-" CLO' & 4 _ Ire •, • • •7D 47K D -o 0 �� : v' RT OPEN ..... 1 •�,.._..-.-..------......• ' MEN—. • 411 DOS s V- , D (S - -6 IWA• J� 1058 �� ` 10/ A .TAI R w o 46 •�' �r3 ill DN. DN. F ;,• W 10 / win 203 105! A; • -- (� to�� \ DN. ;• . Qti D,P 1064 1049 --� 11061 _ .. 1057 M : �� j :, I , 47K ..��I s'v h A -o "�1 \ ,, �� ; \ 1-1 will �. II \ I` 0 ELEV. r - . iiI N4-2 :0 All CONC. COLON = 1 4 5 • � � 9 N4 -3 .e LOBBY 2S X _• [ 202) U N4- SV 2S b J •< .'j.,. V-6 �� \�Imil Hag (E .• • -��� Notes n n n u n ■ N3-4 � 9 8 0 1 Route Cable To Fire Alarm J Box on Lower Level k\2 Route Cable To Fire Alarm J Box Upper Level - 3Elevator Controllcr for Primary Recall n o n 4 Route Cable to Elevator Controller fo^ Alternate Recall 0 0 11 o a 3 a a e a a 5 e c to connection for el vafto^ coQroll6 fire hat �^� 6 Reference Octails iig 54 5 e cction for Wi Interface 7 monitoring for damper _ / / position switches 8 Route Conductors to HVAC Fan Shutdown Interface 9 Route Switch Leg to Damper Circuit Breaker for Damper Activation NOTE: 3 DAMPER A. SUPPLY AIR DAMPERS B. RETURN AIR DAMPERS POWER CIRCUITS ARE REQUIRED•10 ADDRESS Route Switch Leg to Return Air Damper Circuit Breaker 11 Route Switch Leg to Supply Air Damper Circuit Breaker C. FIRE SMOKE DAMPERS 12 Cable for Elevator Cab Speaker and is Routed to Cab via Elevator Traveling Cable. P DAMPERS MUST HAVE TWO POSITION SWITCHES. MOD 1049-1064 ONE N/C THAT OPENS WHEN THE DAMPER IS OPENED. DET 1046-1066 ONE THAT CLOSES WHEN THE DAMPER IS CLOSED. 13 Gutter Mounted Over FACP, VECP 14 Route Cable to Pressurization Fan Starter Contacts 15 Non System Heat Detector for Elevator Shunt Trip Only, Mount Within 18" of Sprinkler Head 16 Locate EOLP in back box for FCM-1 17 Control module for APS circuits 1 & 2 18 Control module for APS circuits 3 & 4 19 Route Conductors to Exhaust Fan Shutdown Interface 20 Route cable to voice riser in South Stair 21 Route Cable to gutter over Voice Panel 22 Proper supervision will require feed and return wiring for all elevator cab speakers except the EOL 23 RF -1 and RF -2 start and motorized dampers operate only on activation of manual damper switch on graphic 24 25 SECOND FLOOR PLAN /\ • 26 27 SCALE: 1/8" = 1'-0" .9- cn z 0 VSS! IREV. BY:I DESCRIPTION 0 z 4100 Alderwood Mali Blvd, Suite 3 Lynnwood, Wa. 98036 FAX (425) 697-2155 TEL. (425) 697-2116 W 0 LL z IL o 0(D l --I U� F w ~ w W u J o m W Ec Z 0 I Z cc Cr w z H WQ F -i C Z �-- J WLO 0 1 cTh CC L,L SCALE: AS NOTED PROJECT NUMBER: 1239 DRAWN DESIGNED BY: BY: DME JMC CHECKED BY: INITIALS DATE: 8/20/03 j SHEET FA -5 L.L.C. ALL RIGHTS 1111111111111 JIM OPEN �3 CONC. \\`%\\\\\\�\\��1\\\\\Z\\\1 t\\\'�\ 11 Ert0 ROOF BELOW 47K V-7 N5-1 306 ;•I\�it•II.11 11.1 t 1.NMINN �. AMMOMIIMMI WMM Immo U=M 61,111=4141=M �!©1071;•1 DN. UP STAIR ,'2 571 WOMEN MEN N5-1 ELEV. 1074 TOR BY D,P,2 D,P TA '..erMOMMWMEMMWMMIkAL .116.51M m w ,1072 AiAj UP DN. SpTA I R ; 3 D,P, ROOF BELOW UMMEMIEWITNI 1074 �'�'' Like MOINedgiWAMErgil D,P,V S40 CONC. COLUMN N5-2 ROOF BELOW ROOF BELOW 23— Dec -2003 PLOT DATE: NOTE: 3 DAMPER OWER .CIRCUITS ARE REQUIRED A. SUPPLY AIR DA PERS B. RETURN AIR DAMPERS C. FIRE SMOKE DAMPERS DAMPERS MUST HAVE TWO POSITION SWITCHES. ONE N/C THAT OPENS WHEN THE DAMPER IS OPENED. ONE THAT CLOSES WHEN THE DAMPER IS CLOSED. ADDRESS MOD 1065-1078 DET 1067-1080 Flag Notes 1 Route Cable 2 Route Cable 3 Route Cable 4 Route Cable 5 Route cable -o Fire Alarm J Box on Lower Level -o Fire Alarm J Box Upper Level to Elevator Controller for Primary Recall to Elevator Controller for Alternate Recall to connection for elevator controller fire hat DESCRIPTION DATE 6 Reference Connection Details for Wiring Tnterfare lO 7 for damper monitoring position switches 0 0 ] o a 8 Route Conductors to HVAC Fan Shutdown Interface 9 Route SwitrJ `pq to Damper Cirruit Rr-. - . • unar Artivatrnn 0 0 10 Route Switch Leg to Return Air Dampe tircuft Break&r 9 f ° 0 11 Route Swit-h 120 Cab14 for 1ev. 1 - • • •. ' 1. _.• or Crab Speaktr an -i 1 Circuit Breaker Rout to ca vi Eleva`.or Traveling Cable. ROOF OW = 13 Gutter Moulted Over FACP, VECP 14 Route Cable to 15 Non System Heat 16 Locate EOLP :n 17 Control module 18 Control module 19 Route Conductors 20 Route cable to 21 Route Cable to 22 Proper supervision 23 RF -1 and RF -2 24 25 26 27 Pressurization Fan Detector for Elevator back box for FCM-1 for APS circuits 1 for APS circuits 3 to Exhaust Fan Shutdown voice riser in South gutter over Voice Panel will require feed start and motorized Starter & 2 & 4 Stair and dampers Contacts Shunt Trip Only, Mount Interface return wiring for all operate only on activation 'tRF1eEL'NSprinkler elevator cab speakers of manual damper Head except the EOL switch on graphic THIRD FLOOR PLAN O� SCALE'. /B" = 11-0" O� N ce REV. BY:1 DESCRIPTION DATE lO co o ") o cv ci c0 w N C 4. . . M .2 N m Ts O 0 O 0 TEL. (425) 697-2116 DJ z 0 CD V I W J I— LUc z z z 2E5 H in CU Cr H LL_ C SCALE: AS NOTED PROJECT NUMBER: 1239 DRAWN BY: DME DESIGNED BY: JMC CHECKED BY: INITIALS DATE: 8/20/03 SHEET FA -6 -D 108 108 DATA 47K N5-4 V-7 DN. UP STAIR #2 ki o—D,P,2S fid 1089 ELEVATOR LO BY 4"3 ' '2S -- 1082 1093 o_AMMIL IIMMOWAV PEN OFFICE 0.• ' C ► SHAFT: P, . 1085 D,P S N5-3 0 N5-3 NOTE: 3 DAMPER POWER CIRCUITS ARE REQUIRED A. SUPPLY AIR DAMPERS B. RETURN AIR DAMPERS C. EIRE SMOKE DAMPERS DAMPERS MUST HAVE TWO POSITION SWITCHES. ONE N/C THAT OPENS WHEN THE DAMPER IS OPENED. ONE THAT CLOSES WHEN THE DAMPER IS CLOSED. 23—Dec-2003 PLOT DATE: ADDRESS MOD 1079-1090 DET 1081-1094 e>4 Flag Notes Wilirjl N 1 • 713.1 ll 4:1 419 ,:-' DESCRIPTION 9 Route Cable to Elevator Controller for Alternate Recall 0.• ' C ► SHAFT: P, . 1085 D,P S N5-3 0 N5-3 NOTE: 3 DAMPER POWER CIRCUITS ARE REQUIRED A. SUPPLY AIR DAMPERS B. RETURN AIR DAMPERS C. EIRE SMOKE DAMPERS DAMPERS MUST HAVE TWO POSITION SWITCHES. ONE N/C THAT OPENS WHEN THE DAMPER IS OPENED. ONE THAT CLOSES WHEN THE DAMPER IS CLOSED. 23—Dec-2003 PLOT DATE: ADDRESS MOD 1079-1090 DET 1081-1094 e>4 Flag Notes 1 Route Cable To Fire Alarm J Box on Lower Level 2 Route Cable To Fire Alarm J Box Upper Level 3 Route Cable to Elevator Controller for Primary Recall DESCRIPTION 9 Route Cable to Elevator Controller for Alternate Recall \ \ DATE 10 Z 5 Route cable to connection for elevator controller fire hat 6 Reference Connection Details for Wiring Interface 7 monitoring for damper "asition switches 0 0 0 0 8 Route Conductors to H Fan Shutdown Interface 9 9 Route Switch Leg to Damper _ Circuit Breaker for _ - 1 Eamper Activation 11 Route Switch Leg to ~upply Air Damper Circuit _ eaker Breaker :3 12 Cable for Elevator Cab Speaker and is Routed to Cab via Elevator Traveling Cable. 13 Gutter Mounted Over FACP, VECP 14 Route Cable to Pressurization Fan Starter Contacts 15 Non System Heat Detector for Elevator Shunt Trip Only, Mount Within 18" of Sprinkler Head 16 Locate EOLP in back box for FCM-1 17 Control module for APS circuits 1 & 2 18 Control module for APS circuits 3 & 4 19 Route Conductors to Exhaust Fan Shutdown Interface 20 Route cable to voice riser in South Stair 21 Route Cable to gutter over Voice Panel 22 Proper supervision will require feed and return wiring for all elevator cab speakers except the EOL 23 RF -1 and RF -2 start and motorized dampers operate only on activation of manual damper switch on graphic 24 25 26 27 = n B 0 a FOURTH FLOOR PLAN eSCALE'. /8" REV. BY: DESCRIPTION DATE 10 Z 4100 Aldorwood Mall Blvd, Salto 3 Lynnwood, Wa. 98036 FAX (425) 697-2155 TEL. (425) 697-2116 W 0 LL 0 1 0 2 6 w J H W 1- 0 0 W Z J W 0 1 WASHINGTON 12500 TUKWILA INTERNATIONAL BLVD SEATTLE Ir Q C SCALE: AS NOTED PROJECT NUMBER: 1239 DRAWN BY: DME DESIGNED BY: JMC CHECKED BY: INITIALS DATE: 8/20/03 SHEET FA -7 23—Dec-2003 PLOT DATE: LOW ROOF CANOPY BELOW LOW ROOF LOW DECK L 0 0 o 0 J SLOPE 1/4"/Ff• MIN. w 0_ 0 -J Cn w 0 J Cr) N RIDGE 0 1 SLOPE ilAcu/FT. MI -P1— --- STAIR STAIR #2 PENTHOUSE R04 w 0 0 0 J w 0_ 0 -J (n 1_12L.:1 0 -J Cn z F L LOW DECK 1�4„�� MIN•, SCOPE 0 SLOPE 1!N. SLOPC 411 FT. MIN. 4 p /FT 5�= 1 SL a - LOW DECK LOW ROOF LOW ROOF tanT W' • SLOPE / SLOPE 1 MVIIN.\ I I 1 II 1 111111 1111 1 uz =1 —1 — ---; ---71 _t- - _r----1111-- _T DN — — .IIT — ,l- - -- 11L_ = — -_, -- -4- - ,- -r- • = : F- 109 4 1098 1111111111111111 < 11091 FAN SF -4 1092 D,P 1093 K STAIR PRESSURIZATION FAN 47K c:-D,P AC UNIT FUTURE FAN D,P AC UNIT 1096 D.P n n n 1106 rF ,Th 4k2 1 101 GO ELEVATO D PENTHOUSE 1103 R01 1102 1104 V-8 ' D► Ed TYf°1CAL ELEVATOR CAB(X4) SPEAKER (4,3 s --s®, 1107 1108 ELEVATOR 1111111 u u 111111 loori 11111111111111 1109 ELEVATOR SHAFT P'rSSURIZATION FAN ELEVATOR HAFT PRESSURIZATION FAN D,P ELEC AC UNIT AC -4 1102 7K 7K SF -2 FA 1103 D,P RF -1 FAII7K 1104 1105 7K M fN- SLOPE 1 F MIN. SLOPE LOW ROOF LOW ROOF • 4 Ip LOW ROOF ADDRESS MOD 1091-1114 DET 1097-1107 LOW ROOF SCREEN WALL PER 1 /A4.2 0- 0 Db,P morn FAN SF -3 STAIR PRESSURIZATION FAN D.P 1110 1111111,11111111 D r D,2P-O ALL - - - -1111--- - 411+-- t_ T r fr 47K U : 4, g LI- : 1 yy 1113 --1105 UNlIT106 AC -1 STAIR #3 PENTHOUSE R08 D,P RIDGE Flag Note .•E Route Cable T Cable T t 2 R•-- 3 Route Ca• - 4 Route Cable t 8 Route cabite Reference monitor Rou - t n Conduct ute Switch Fir? Al Fire Ele • w0 ecti ors eg arm J Box o •wer Level Alarm J :.x Upper Level a Controller for Primary Recall ator Controller for A11t/pn- e Recall ection for elevator co Nre hat 1 Detai 1 ■ aui,Ga. mma-ismer.r.mmaamwi a*: nterface MIN. SLOPE 0 —CD 7/4'�� StsGp MIN. SLOPE /4»/FT MIN. LU 0 0 J (J) w 0 0 J w 0_ 0 -J z z a_ LU 0 J (n 0 0 CC 0 J 0 0 D 0 J LOW DECK 0 11 1 14 15 16 17 18 19 20 21 22 23 24 25 26 27 VAC Fan Shutdown Interface amper CfiOgpip40Br aker f )r Damp_r4cpkyaion eturn Air Damper Circuit Breaker Route Switch eg 11 - Cab1eLdpir F». ator' C Gutter Mounted 0vrr upply Air Damper Circui b SpeakrwohAW Routed ACP, VECP t Breaker to Cab via Elevator Traveling Cable. Route Cable to Pressurization Fan Starter Contacts Non System Heat Detector for Elevator Shunt Trip Only, Mount Locate EOLP in back box for FCM-1 Control module for APS circuits 1 & 2 Control module for APS circuits 3 & 4 Route Conductors to Exhaust Fan Shutdown Interface Route cable to voice riser in South Stair Route Cable to gutter over Voice Panel Proper supervision will require feed and return wiring RF -1 and RF -2 start and motorized dampers operate only AC unit shutdown With n 18” of Sprinkler Head for all elevator cab speakers except the EOL on activation of manual damper switch on graphic ROOF POWER PLAN OD SCALE: 1/8" = a' -o" IREV. BY:1 CANOPY BELOW DESCRIPTION DATE 11 1 14 15 16 17 18 19 20 21 22 23 24 25 26 27 VAC Fan Shutdown Interface amper CfiOgpip40Br aker f )r Damp_r4cpkyaion eturn Air Damper Circuit Breaker Route Switch eg 11 - Cab1eLdpir F». ator' C Gutter Mounted 0vrr upply Air Damper Circui b SpeakrwohAW Routed ACP, VECP t Breaker to Cab via Elevator Traveling Cable. Route Cable to Pressurization Fan Starter Contacts Non System Heat Detector for Elevator Shunt Trip Only, Mount Locate EOLP in back box for FCM-1 Control module for APS circuits 1 & 2 Control module for APS circuits 3 & 4 Route Conductors to Exhaust Fan Shutdown Interface Route cable to voice riser in South Stair Route Cable to gutter over Voice Panel Proper supervision will require feed and return wiring RF -1 and RF -2 start and motorized dampers operate only AC unit shutdown With n 18” of Sprinkler Head for all elevator cab speakers except the EOL on activation of manual damper switch on graphic ROOF POWER PLAN OD SCALE: 1/8" = a' -o" IREV. BY:1 DESCRIPTION DATE IO Z 4100 Aldorwood Mall Blvd, Suite 3 Lynnwood, Wa. 98036 FAX (425) 697-2155 TEL. (425) 697-2116 w 0 u. 0 0 2 6 w J 1-- 1- w 1 2 0 w co ca Z J w 0 1 WASHINGTON LU W C1) 0 co:_!71 CD Cr LUF-- :2: 1-1 F --I 0 0 (J LU CC !—I LL C SCALE: AS NOTED -\ PROJECT NUMBER: 1239 DRAWN BY: DME DESIGNED BY: JMC CHECKED BY: INITIALS DATE: 8/20/03 J SHEET FA -8 RESERVED. L.L.C. ALL RIGHTS BY PRECISION ALARM, COPYRIGHT 23—Dec-2003 PLOT DATE: V5-84 o-2S,2V :o:o: V-9 D D D 0 b Ix b o bLa ROOF o -V N5-4 V-8 V D,P N5-3 5 D,P 0 0 v 2V 4TH FLOOR Flag Notes 1 Route Cable To Fire Alarm J Box on Lower Level 2 Route Cable To Fire Alarm J Box Upper Level 3 Route Cable to Elevator Controller for Primary Recall 4 Route Cable to Elevator Controller for Alternate Recall 5 Route cable to connection for elevator controller fire hat 6 Reference Connection Details for Wiring Interface 7 monitoring for damper position switches 8 Route Conductors to HVAC Fan Shutdown Interface 9 Route Switch Leg to Damper Circuit Breaker for Damper Activation 10 Route Switch Leg to Return Air Gamper Circuit Breaker 11 Route Switch Leg to Supply Air Damper Circuit Breaker 12 Cable for Elevator Cab Speaker and is Routed to Cab via Elevator Traveling Cable Op -S IAPS- 11OVAC 0 3V 3RD FLOOR 13 Gutter Mounted Over FACP, VECP 14 Route Cable to Pressurization Fan Starter Contacts 15 Non System Heat Detector for Elevator Shunt Trip Only, Mount Within 18" of Sprinkler Head 16 Locate EOLP in back box for FCM-1 17 Control module for APS circuits 1 & 2 18 Control module for APS circuits 3 & 4 19 Route Conductors to Exhaust Fan Shutdown Interface 20 Route cable to voice riser in South Stair 21 Route Cable to gutter over Voice Panel 22 Proper supervision will require feed and return wiring for all elevator cab speakers except the EOL 23 RF -1 and RF -2 start and motorized dampers operate only on activation of manual damper switch on graphic 24 25 26 27 D,P-c) 110VAC 4V 2ND FLOOR o -V V4 ELEVATOR CAB D,P D.P D,P N3-2 N3-3 D,P-c DCD DEDICATED 120VAC GUTTER J -BOX FACP c -D,3V BATTERIES D.P AMPLIFIER o-D,2V V2 110VAC IC IC GRAPHIC SMOKE CONTROL ANN D P D6P D6P OM :© D,P EOLR D P D.P DP - IC o EOLR 1ST FLOOR P-1 P-2 o-D,V N1 -2 D 6 �-s ,.N 1-4 1APS-1 110VAC N1-3 V-1 o -J P-3 RISER DIAGRAM SCALE: NONE N Z O N 51 cocr DESCRIPTION La I— AC 0 O Z 4100 Alderwood Mali Blvd, Salto 3 Lynnwood, Wa. 98036 FAX (425) 697-2155 TEL. (425) 697-2116 W 0 11. Lin CD 0E6 z Q rc w ® 1--- W CJD 1J m aJ W Q z 0 cc cc W D UH WQ I—I I— 0 J o W c 0 1 C SCALE: AS NOTED PROJECT NUMBER: 1239 DRAWN DESIGNED BY: BY: DME JMC CHECKED BY: INITIALS DATE: 8/20/03 SHEET FA -9 23—Dec-2003 PLOT DATE: ROOF LEVEL 4 LEVEL 3 LEVEL 2 LEVEL 1 LEVEL P1 LEVEL P2 LEVEL P3 PRESSURIZATION EXHAUST AIR SYSTEMS PRESSURIZATION AIR SYSTEMS EXHAUST DEPARTMENT OF HOMELAND SECURITY SEATTLE, WASHINGTON ELEVATOR PENTHOUSE PRESSURIZATION PRESSURIZATION EXHAUST L 1 SMOKE DETECTORS L i' MANUAL STATION DUCT SMOKE DETECTORS PRESSURIZATION SUPPLY AIR 1 STAIR #3 OPEN LEVEL 4 RETURN AIR DAMPERS AUTO LEVEL 3 RETURN AIR DAMPERS LEVEL 2 RETURN AIR DAMPERS CLOSED OPEN AUTO CLOSED OPEN AUTO CLOSED OPEN LEVEL 1 RETURN AIR DAMPERS AUTO CLOSED GRAPHIC ANNUNCIATOR SCALE: 1" = 1" REV. BY: ELEVATOR 4 & 5 ''c DESCRIPTION N c ELEVATOR 2 & 3 ®WATERFLOW ® SMOKE DETECTORS DATE ` / Q MANUAL STATION DUCT SMOKE 'DETECTORS TAMPER SWITCH ® WATERFLOW ® SMOKE DETECTORS \ / 1 MANUAL STATION EXHAUST AIR EXHAUST AIR `- DUCT SMOKE DETECTORS ' TAMPER SWITCH ® WATERFLOW L J SMOKE DETECTORS j.. ® MANUAL STATION STAIR #1 DUCT SMOKE DETECTORS ! '` TAMPER SWITCH r Cr 0 ® WATERFLOW ® SMOKE DETECTORS \ ®MANUAL STATION W 111 ROOM HIGH -LOW AIR ; TAMPER SWITCH FIRE 0 RUN 1 PUMP i .- TROUBLE ^�� ; R HEAT TAPE You ARE HERE ®WATERFLOW ® SMOKE DETECTORS C) MANUAL STATION :', DUCT SMOKE ... DETECTORS TAMPER SWITCH I Q WATERFLOW O SMOKE DETECTORS ® MANUAL STATION TAMPER SWITCH 1 WATERFLOW Q SMOKE DETECTORS ® MANUAL STATION -'' ' TAMPER SWITCH ! OPEN LEVEL 4 RETURN AIR DAMPERS AUTO LEVEL 3 RETURN AIR DAMPERS LEVEL 2 RETURN AIR DAMPERS CLOSED OPEN AUTO CLOSED OPEN AUTO CLOSED OPEN LEVEL 1 RETURN AIR DAMPERS AUTO CLOSED GRAPHIC ANNUNCIATOR SCALE: 1" = 1" REV. BY: DESCRIPTION DATE 0 Z to in M to O CO N • 1.0 N O v 0 3 x c C La - J>. M 0 V) > 0 0 O 0 0 0 0 TEL. (425) 697-2116 W U 0 0 Et' V/ a W J ✓ ♦♦W V! >" I- Fr" U W 0 z J W 0 WASHINGTON LLJ W Cf) 0 m CD CC LLJ z I -I c c CC LLJ CC I -I I SCALE: AS NOTED PROJECT NUMBER: 1239 DRAWN DESIGNED BY: BY: DME JMC CHECKED BY: -DB INITIALS DATE: 8/20/03 SHEET FA -1O d cL' W W cr Note. device shown for identification only Existing Devices in Gray Scale Wire Legend Symbols Legend Description Description Mounting Manufacturer Part # Symbol QTY West Penn D990 1 Display Annunciator 0 ABF -20B Enclosure at 66" to Top Notifier LCD -160 ANN N R 123 Intelligent Photo Smoke Detector w/ Relay Base for Door Strike 485 Network Circuit 4 Square Deep with 3" Round Ring Notifier FSP -851 with B224RB Relay base T 3 Intelligent Multi Sensor Smoke Detector 2 14 AWG THHN Fire Rated (in EMT) 4 Square Deep with 3" Round Ring Notifier FAPT-851 with B7101p base iii 25 Intelligent Photo Smoke Detector Red Jacket Fire Cable tag for ckt type 4 Square Deep with 3" Round Ring Notifier FSP -851 with B7101p base 1 Intelligent Manual Pull Station ''j`''ot 1 Gang at 48" to Top Notifier NBG-I2LX F S 1 pair 14.AWG Fire Rated Cable (FPLP) 16 Intelligent Duct Smoke Detector Strobe (NAC) Circuit Plenum Surface (Ref. Mfg Information) Notifier FSD-751P is 4 Intelligent NAC Control Module,;.., 1 pair 14 AWG Twisted Shielded Fire Rated Cable (FPLP) SBB Back Box supplied by PA Notifier FCM-1 4 Audible Power Supply Surface Notifier FCPS-24S6 APS 3 Selectable -Output Speaker/Strobe at 110cd t ,. 4 Square Deep Notifier SP2RI224MC 0 17 CEILING Strobe i5cd 4 Square Deep Notifier SC2W2415W ® 15 CEILING Strobe 95cd 4 Square Deep Notifier SC2W2495W CA 3 Ceiling Speaker 4 Square Deep Notifier SP200W 044 90 CEILING Speaker / Strobe 15cd 4 Square Deep Notifier SP2C2415 q>44 34 CEILING Speaker / Strobe 30cd 4 Square Deep Notifier SP2C2430 044 26 CEILING Speaker / Strobe 75cd 4 Square Deep Notifier SP2C2475 04 4 CEILING Speaker / Strobe 95cd 4 Square Deep Notifier SP2C2495 Fire Alarm Cable Routed as Open Wire Supplied by Others QQ Fire Alarm System "J" Box Sized for Conductor Fill Supplied by Others Note. device shown for identification only Existing Devices in Gray Scale Wire Legend Symbol Description MFG. Part Number Color Coded Cable Type of Circuit Application D 1 pair 16 AWG Twisted NON Shielded Fire Rated Cable (FPL) West Penn D990 Red Jacket Fire Cable tag for ckt type Data (SLC) Circuit 0 1 pair 16 AWG Twisted NON Shielded Fire Rated Cable (FPLP) West Penn 60991 Red Jacket Fire Cable tag for ckt type Data (SLC) Circuit Plenum N 1 pair i6 AWG Twisted Shielded Fire Rated Cable (FPL) West Penn 0991 Red Jacket Fire Cable tag for ckt type 485 Network Circuit N 1 pair 16 AWG Twisted Shielded Fire Rated Cable (FPLP) West Penn D60990 Red Jacket Fire Cable tag for ckt type 485 Network Circuit Plenum P 2 14 AWG THHN Fire Rated (in EMT) Aux Power Circuit P 1 pair 14 AWG Fire Rated Cable (FPLP) West Penn 60993 Red Jacket Fire Cable tag for ckt type Aux Power Circuit Plenum S 2 14 AWG THHN Fire Rated (in EMT) Strobe (NAC) Circuit S 1 pair 14 AWG Fire Rated Cable (FPL) West Penn 972 Red Jacket Fire Cable tag for ckt type Strobe (NAC) Circuit S 1 pair 14.AWG Fire Rated Cable (FPLP) West Penn 60993 Red Jacket Fire Cable tag for ckt type Strobe (NAC) Circuit Plenum V 1 pair 14 AWG Twisted Shielded Fire Rated Cable (FPL) West Penn D995 Red Jacket Fire Cable tag for ckt type Speaker (NAC) Circuit V 1 pair 14 AWG Twisted Shielded Fire Rated Cable (FPLP) West Penn 60992 Red Jacket Fire Cable tag for ckt type Speaker (NAC) Circuit Plenum Wire Manufacturer is for Reference Purpose Only NOTE. (Y) Type Cable Max length 1,000 ft. between Panels Flag Notes 1 Relocate Circuit End of Line Resistor,from Existing Notification Appliance to this Device 2 Route Cable to New Audible PowervSupply on this Level 3 Route Cable to Gutter Above Voice Evacuation Control Panel via Voice Riser in South Stair 4 Houte Cable to Gutter Above Fire Alarm Control Panel 5 Mount SD on strut in from of damper centered at 18' for each 36' of width. After 72' add one SD for each 24'. 6 No duct detector needed, area served has detection. Sheet Note 1 Tap all Speakers at 1/4 Watt 25 Volts 2 Ambient 45dba as Listed in NFPA 72 A-4-3.2 All Audible Devices are set for 96 dba at 10' 3 Ambient Temperature is Between 65 and 80 degrees 16—Sep--2004 PLOT DATE: GENERAL NOTES 1. INSTALLATION SHALL BE ACCOMPLISHED IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE AHJ'S, NEC, AND CONTRACT DRAWINGS. 2. WIRE ROUTING IS DIAGRAMMATIC IN NATURE ONLY AND NOT INTENDED FOR ACTUAL CONDUIT ROUTING. 3. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ. 4. THE SYSTEM SHALL BE MONITORED BY A UL LISTED MONITORING STATION BEFORE AHJ TEST. 5. VERIFY ALL LOCATIONS OF DEVICES WITH ELECTRICAL_/ARCHITECTURAL PLANS. SCALE AND PLACE ALL DEVICES PER ELECTRICAL/ARCHITECTURAL PLANO. 6. FIELD VERIFY WATER FLOW, SPRINKLER, SMOKE DAMPERS AND DUCT DETECTOR LOCATIONS. 7. FIELD VERIFY ALL WIRING LOCATIONS AND REQUIREMENTS FOR HVAC AND FAN CONTROL. 8. SMOKE DETECTORS SHALL NOT BE LOCATED WITHIN 3'-O" OF AIR DIFFUSERS. 9. NFPA 5-3.6.1.3 REQUIRES THAT NO SMOKE DETECTORS ARE TO BE INSTALLED UNTIL AFTER FINAL CONSTRUCTION CLEAN-UP. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO CLEAN-UP MUST BE CLEANED OR REPLACED ACCORDING TO CHAPTER 7AND WILL BE INVOICED ON A TO BASIS. 10. FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF TECHNICIANS. 11. ALL CIRCUITS WILL BE PROPERLY TAGGED AND TESTED FOR OPENS, SHORTS, GROUNDS AND PROPER END.OF THE LINE RESISTANCE. EACH CIRCUITS METER READING MUST BE DOCUMENTED AND PRESENTED TO. FIELD TECHNICIAN UPON ARRIVAL ON SITE FOR CHECKOUT. 12. A SET OF INSTALLATION AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY FIELD TECHNICIANS. 13. AGREEMENT AND CONFIRMATION OF ALL MILESTONE EVENTS WILL BE MADE WITH PROJECT MANAGER. SERVICES MUST BE SCHEDULED WITH PROJECT MANAGER WITH A MINIMUM OF TEN WORKING DAYS NOTICE. 14. NO TAPPING OF SIGNALING OR INITIATING ZONE CIRCUITS ARE ALLOWED. T -TAPPING OF STYLE 4 ADDRESSABLE CIRCUITS IS ALLOWED PROVIDING SPLICE IS PROFESSIONALLY INSTALLED, POLARITY IS OBSERVED, SHIELDS ARE CONTINUOUS AND FREE OF G:,JUNDS. SHIELDS SHALL BE TERMINATED AT FACP ONLY. "CABLE SHIELDS SHALL BE SPLICED TOSETHER AT EVERY JUNCTION BETWEEN THE FIRE ALARM PANEL ANO THE LAST DEVICE ON EACH CABLE SHIELDS AND OTHER FIRE ALARM CONDUCTORS (EXCEPT POWER GROUNDS) SHALL ,BE INSULATED AND COMPLETELY FREE FROM CONDUIT OR EARTH GROUNDS. SHIELDS WILL BE TIED TO GROUND ONLY AT THE FIRE ALARM PANEL BY THE INSTALLING FIRE ALARM TECHNICIAN." 15. MOUNT AUDIBLE/VISUAL DEVICE BACKBOX FROM A MINIMUM OF 80" TO A MAXIMUM OF 96" AFF, SEE FLOOR PLANS FOR CANDELA RATING OF DEVICE BEING INSTALLED. 16. AS BUILTS ARE REQUIRED AT TIME OF AHJ ACCEPTANCE. PRECISION ALARM NEEDS RED LINE AS BUILTS 2 WEEKS PRIOR TO AHJ TESTS. 17. NO LINE VOLTAGE IN CONDUIT WITH FIRE ALARM WIRE. 18. ALL MANUAL PULL STATIONS ARE TO BE MOUNTED AT ,".: HIGH NO GREATER THAN 48" TO TOP AND A HEIGHT NO LESS THAN 36" TO BOTTOM. DEVICE DESIGNATION LEGEND NOTIFICATION DEVICES: POWER SUPPLY NUMBER CIRCUIT TYPE: "N" = FIELD "P" = PANEL n -o X POWER SUPPLY CIRCUIT NUMBER STROBE CANDELA DESIGNATION = 15cd = 30cd = 75cd = 95cd = 1 10cd = AUDIBLE ONLY ADDRESSABLE INITIATING DEVICES: PANEL DATA LOOP NUMBER DEVICE ADDRESS D 1-127 D s 2 bs D 1-127 D EXAMPLE REMOVE TAB ON DIAL FOR ADDRESSES 100 AND ABOVE Sheet Schedule Sheet Number Description FA -0 Symbols Legend, Wire Legend, General Notes FA -1 Parking Level 3 Plan FA -2 First Floor Plan FA -3 Second Floor Plan FA -4 Third Floor Plan FA -5 Fourth Floor Plan FA -6 Riser Diagram % ACCEPTED [} Without Comments As Noted In Red (� Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void thisacceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: / /0(7. By: rUKWILA FIRE DEPARTM .N1 Please call: 575-4407 and give this job No. 61 '—F/ '? and exact address for shut- down or restoration approval. Ravi sEb 9/�°l°Se N z 0 N La t>: m DESCRIPTION cn W ca z Q 4 Ct1- V r V 4C is G 04 00 O N WASHINGTON W LJF -- F -- Cf) Q 0 Q CC LLJ z H 1-1 cD LC) nj r -i CC LL SCALE: AS NOTED PROJECT NUMBER: 1239 DRAWN BY: DME DESIGNED BY: TLB CHECKED BY: INITIALS DATE: 02/13/04 J SHEET FA -0 16--Sep--2004 PLOT DATE: N1 - V -1 47K RECEIVING STORAGE TP314 STORAGE TP304 N1-3 2S,2V RAMPY-1 ELEC RISER IN C !LING 1016 INION DOG GE o FD OU IN CEIU N1- 1 IST-1CORRIDOR ELEV. 5 #5 ' EXIT CORRIDOR BICE 41c, 0 ST•' M 1�6 0 UP STAIR #3 FD DOG CAGE D,S,2V 1006 PARKING Flag Notes 1 Relocate Circuit End of Line Resistor from Existing Notification Appliance 2 Route Cable to New Audible Power Supply on this Level 3 Route Cable to Gutter Above Voice Evacuation Control Panel via Voice Riser 4 Route Cable to Gutter Above Fire Alarm Control Panel 5 Mount SD on strut in front of damper centered at 18' for each 36' of width. 6 No duct detector needed, area served has detection. to this Device in South Stair After 72' add one SD for each 24'. Sheet Note 1 Tap all Speakers at 1/4 Watt 25 Volts 2 Ambient 45dba as Listed in NFPA 72 A-4-3.2 All Audible Devices are set for 96 dba at 10' 3 Ambient Temperature is Between 65 and 80 degrees 4 X8,5 5D PARKING LEVEL 3 PLAN p0 REV. BY: TLB TLB DESCRIPTION ARCHITECTURAL CHANGES CORRIDOR DETECTOR ADDITIONS DATE 1OS/24/04 08/24/04 1 N N z O N 11111.11401. J 0 3 Lynnwood, Wa. 98036 4100 Alderwood Ma FAX (425) 697-2155 TEL. (425) 697-2116 WASHINGTON 12500 TUKWILA INTERNATIONAL BLVD SEATTLE CC H LL SCALE: AS NOTED PROJECT NUMBER: 1239 DRAWN BY: DME DESIGNED BY: TLB CHECKED BY: INITIALS DATE: 02/13/04 J SHEET FA -1 W W (1) o 16--Sep--2004 0 \\\\\\\\\\\\\\\\\\\\\\\\\\\\\ K\ <\ 1 s.v \ 1— EHIAIN LINK FENCING IN OPENING. (2'-0" HIGH x 22'-0" WIDE) \\\\\\\\\\\\\\\\\ \\ -f\ \ \ \ \ \\ \ \ \_\ \ \ \ l v1 CHAIN LINK FENCING IN OPENING. (2'-C" HIGH x 22'-0" WIDE) PAINTED STRIPING $-N \ CONC. COLUMN \\ \\\ \ \ \ \ \ \ \ \ \ \ \ \ \ \\ \ \ \ \ \ 2S -55-N2-1 V-2 o-2S,2V N2- S.V 1008 X D,SV g� 4` DA TB 1 [P203) pr • ••• •• • .... 2.2K REVISED TO MATCH PRE-SET CONDUIT ROUTE REVISED NAC AND SLC CIRCUITS FOR TENANT IMPROVEMENT . DATE J 0 C) CI —I 1" 1/1 UP TAIR #2 1 P204 6 o i I0 STORAG ELEV. e i D,S,V N2-2 D,S,V 1009 D,2S,2V N2 1 V-2 C C EXHAUST FAN WITH SHAF TO DAYLIGHT ABOVE. SEE MECHANICAL DRAWINGS. 8" CONCRETE SHAFT WAL_S PER STRUCTURAL. <\ ADDRESS MOD 1007-1009 DET 1005-1006 V-2 P2 VOICE CIRCUIT PARKING P201 D,S,V 2 N2}-2 V- $-N F'y 2 X D,S,V Flag Notes \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \_\ \ \ \ 1 1 1 1p 18 19 Route Cable To Fire Alarm J Box on Lower Level Route Cable_To Fire_Alarm J Box Upper Leve\ Route Cable to Elevator Coitroller for P Route Cable to Elevator Co,troller for A ,may Recall lternate Recall Route cable to connection for elevator crntroller Reference Co,nection Details for Wiring Interface monitoring fir damper position switches Route Conductors to HVAC Fan Shutdown Inte Route Switch Circuit Breakar Route Switch Air Damper Route Switch Air Damper Cable for Elavator Cab Speaker and is Gutter Moantad Over F -ACP, VECP Leg to Damper Leg to Return Leg to Supply fire hat face fo' Damper Activation Ci^suit Ci^suit Routed Route Cable to Pressurization Fan Starter Non System Heat Detector for Elevator Shun Locate EOLP in back box for FCM-1 Control module for APS circuits 1 & 2 22 2b 214 2 2 Breaker Breaker to Cab via Elevator Traveling Cable. ontacts Trip Only, Mount Within 18" of Sprinkler Head Control module for APS circuits 3 & 4 S \I Route Conductors to Exhaust Fan Shutdown Ithterface Route cable to voice riser in South Stair Proper supervision will require feed and return wiring for all elevator cab speakers except the RF -1 and RF -2 start and motorized dampers operate only on activation of manual damper switch on C C C \\\\\\\\\\\\ SLOPE 18" C 8" dONCRETE SHAFT WALLS PER - STR CTURAL. EXH UST FAN WITH SHAFT TO DAY IGHT ABOVE. SEE MECHANICAL DRA INGS. \\\\\\\\\\\\\\\ EOL graphic \ \ \\_\ \ \ \_\ \ \ \ \ \ \_\ \ \ \ 0 0 2 LU 0_ 0 RAMP P209 9'-O" DIAMETER CORRUGATED METAL PIPE TO CONCRETE SHAFT PER STRUCTURAL DRAWINGS. L P-2 PARKING PLAN SCALE: 1./8: = 1'-0" VI 0 w ce r CONt TB 1 TB DESCRIPTION REVISED TO MATCH PRE-SET CONDUIT ROUTE REVISED NAC AND SLC CIRCUITS FOR TENANT IMPROVEMENT DATE 1/23/04 C) CZ 1" Wisol v W nnwood, Wa. 98036 M 3 C) 4100 Alderwood Mall 81 FAX (425) 697-2155 TEL (425) 697-2116 r W 0 1 U 2 1 0 6 w 1 W >- 1- 2 U W z W 0 1 WASHINGTON W Q W Cf) CD CC] O t --i F-- :2: LLI F-- :2: i --I 3 O LC) r --i SCALE: AS NOTED PROJECT NUMBER: 1239 DRAWN BY: DME DESIGNED BY: JMC CHECKED BY: INITIALS DATE: 8/20/03 J SHEET FA -2 ) ca m F !» 0z N ce 4 K EF -19 71/2 NP �______t__—__1 H 0 PAINTED STRIPING C. COLUMN SEE ENLARGED ROOM THIS SHEET 6741111111imilk; tr:°;J S> c i MONITOR 1 STORAG la LECTRICA 03 ,49 ► D ELE TOR LO .BY '{!008 ELEV. nnwood, Wa. 98036 407 - 00 Alderwood Mal FAX (425) 697-2155 TEL. (425) 697-2116 2S,2V N2-3 o,s,v PARKING GWB PIPE ENCLOSURE AT UNDERSIDE OF PT DECK ABOVE. D,P,5V CLOSET , PUMPER N AND WATER E L PLAN. 47K C IN ELEVATOR CAB C EXHAUST FAN WITH SHAFT TO DAYLIGHT ABOVE. SEE MECHANICAL DRAWINGS. ' P111 IR1 JPv 8" CONCRETE SHAFT WALLS PER STRUCTURAL METE D METAL ONCRETE L 16--Sep--2004 PLOT DATE: 110VAC FOR DAMPER IN ELEV MACHINE RM TO EF -19 ENLARGED ELECTRICAL ROOM SCALE: NONE ADDRESS MOD 1010-1033 DET 1007-1011 V-2 P1 VOICE CIRCUIT V-4 ELEV VOICE CIRCUIT Fq Notes 2.02n11 7111 II -- ii1ii 1 Route Cable To 2 Route Cable To 3 Route Cable to i i __ rel -- I__ ii Controller for Alternate Recall INIII MINIM DII, UP TAIR , 2 P104 0 la LECTRICA 03 ,49 ► D ELE TOR LO .BY '{!008 ELEV. nnwood, Wa. 98036 407 - 00 Alderwood Mal FAX (425) 697-2155 TEL. (425) 697-2116 2S,2V N2-3 o,s,v PARKING GWB PIPE ENCLOSURE AT UNDERSIDE OF PT DECK ABOVE. D,P,5V CLOSET , PUMPER N AND WATER E L PLAN. 47K C IN ELEVATOR CAB C EXHAUST FAN WITH SHAFT TO DAYLIGHT ABOVE. SEE MECHANICAL DRAWINGS. ' P111 IR1 JPv 8" CONCRETE SHAFT WALLS PER STRUCTURAL METE D METAL ONCRETE L 16--Sep--2004 PLOT DATE: 110VAC FOR DAMPER IN ELEV MACHINE RM TO EF -19 ENLARGED ELECTRICAL ROOM SCALE: NONE ADDRESS MOD 1010-1033 DET 1007-1011 V-2 P1 VOICE CIRCUIT V-4 ELEV VOICE CIRCUIT Fq Notes 1 Route Cable To 2 Route Cable To 3 Route Cable to Fire Fire Elevator Alarm J Box on Lower Level Alarm J Box Upper Level Controller for Primary Recall —� 4 Route Cable to Elevator Controller for Alternate Recall � \\,\,\,\, \ 5 Route cable to Reference Cor connection for elevator controller fire hat Detailsaifor Wiring Interface \ \ rnetion 76 \\\'�`�iter,i g\�P�i�h 8 Route Conducto 9 Route Switch L 10 Route Switch L 11 Route Switch L 12 Cable for Elev 13 Gutter Mounted 14 Route Cable to 15 Non System Heat 16 Locate EOLP in 17 Control module 18 Control module 19 Route Conductors 20 Route cable to 21 Route Cable to 22 Proper supervision 23 RF -1 and RF -2 24 25 26 27 s g g g tor Over Pressurization back for for voice gutter start itb \\\\\\\\\\\N\\\\\\\\\\\\\\\C\ toHVAC Fan utown Interface to Damper Circuit Breaker for Damper Activation to Return Air Damper Circuit Breaker to Supply Air Damper Circuit Breaker Cab Speaker and is Routed to Cab via Elevator FACP, VECP Fan Starter Contacts Detector for Elevator Shunt Trip Only, Mount box for FCM-1 APS circuits 1 & 2 APS circuits 3 & 4 to Exhaust Fan Shutdown Interface riser in South Stair over Voice Panel will require feed and return wiring for all and motorized dampers operate only on activation Traveling Cable. Within i8" of Sprinkler Head elevator cab speakers except the EOL of manual damper switch on graphic EXHAUST FAN WITH SHAFT DAYLIGHT ABOVE. SEE M DRAWINGS. HANICAL P-1 PARKING PLAN pO SCALE: 7/8.• = 1._4" w U HOMELAND SECURITY SEATTLE DISTRICT OFF WASHINGTON 125OO TUKWILA INTERNATIONAL BLVD SEATTLE J /- SCALE: AS NOTED PROJECT NUMBER: 1239 DRAWN BY: DME DESIGNED BY: JMC CHECKED BY: INITIALS DATE: 8/20/03 J C SHEET FA -3 J COPYRIGHT ° 2004 BY PRECISION ALARM, L.L.C. ALL RIGHTS RESERVED. 16--Sep--2004 PLOT DATE: SALLY PORT irjeridir-I_ lbw Ear COPY/ WORK 2049 • FFICER 2011 2054 c—D,P 1 1 rir urn" DESK(1.1.0 !RN) SERVI SEARC ROO 2053 R N3-2 2055 V-5 2S,2V • COPIER 2011 EXIT TO DETAINEE SECURE YARD 0T181 SECURE COR' DO •2 SECURE WEAPONS IN PROCESSING COUNTER REMOVE 2S,2V OUT PR c0u CESSINGD, TER STAIR ;'2 D D 2058 i R cc-D,P,S,2V RINT AREA SERVER N6-1 —v-10 FINGERPRIN HAND WA'+H AREA V - AREA S,2V I' 2S, 2008 HkLON3 132 —ED �—ES RESTROOM tES_TipULE ELEV. #2 2S,2V WOMEN 2137 - PPLICA UPPORT r% eirk64 STAIR 2016 R21 7 D TOR. ROO 2A, D, P, 2V, xxxx CZ ES 2019 ES 2063 2020 ATE TT DE w la =LI N6-2 RV -10' MALE HOLDING 2S,2V TRIAG RELOCATE FEMALE IOSKS/2 HOLDING 2129 D,P RIA ING COUNTERS Os 2023 CORAREAS,v INCOMING/, OUTGOING PROP. STORAG �ti Tenn V-5 C NTACT COUNTER T160, STAIR #1 EAD PROC PRIVATE RIVATE FICE SHIER FFI. E (' s 2S,2V VESTIBULE QUEUING v- <7.) - 1 Flag Notes 1 Relocate Circuit End of Line Resistor from Existing Notification Appliance to this Device 2 Route Cable to New Audible Power Supply on this Level 3 Route Cable to Gutter Above Voice Evacuation Control Panel via Voice Riser in South Stair 9 Route Cable to Gutter Above Fire Alarm Control Panel 5 Mount SD on strut in front of damper centered at 18' for each 36' of width. After 72' add one SD for 6 No duct detector needed, area served has detection. each 24'. Sheet Note 1 Tap all Speakers at 1/4 Watt 25 Volts 2 Ambient 45dba as Listed in NFPA 72 A-4-3.2 All Audible Devices are set for 96 dba at 10' 3 Ambient Temperature is Between 65 and 80 degrees FIRST FLOOR PLAN SCALE'. 1/8" = 1 -4 N O col CC CO W CZ CO 1 -- CD J DESCRIPTION W Q a 04 0 z tV J KIJ Blvd. Sulfa 3 Lynnwood, Wa. 98036 4100 Alderwood Ma FAX (425) 697-2155 TEL (425) 697-2116 WASHINGTON LLJ J LJ a J 0 Cr LL1 z J 0 0 1 CE LL_ SCALE: AS NOTED PROJECT NUMBER: 1239 DRAWN BY: DME DESIGNED BY: TLB CHECKED BY: INITIALS DATE: 02/13/04 , SHEET I 1 \ ' 7v 200".x`` -- !! AVM! 4 RE w iV �I 1 P --i •• liTir-EiI 7\ ImP tr - :. • - , D 2058 i R cc-D,P,S,2V RINT AREA SERVER N6-1 —v-10 FINGERPRIN HAND WA'+H AREA V - AREA S,2V I' 2S, 2008 HkLON3 132 —ED �—ES RESTROOM tES_TipULE ELEV. #2 2S,2V WOMEN 2137 - PPLICA UPPORT r% eirk64 STAIR 2016 R21 7 D TOR. ROO 2A, D, P, 2V, xxxx CZ ES 2019 ES 2063 2020 ATE TT DE w la =LI N6-2 RV -10' MALE HOLDING 2S,2V TRIAG RELOCATE FEMALE IOSKS/2 HOLDING 2129 D,P RIA ING COUNTERS Os 2023 CORAREAS,v INCOMING/, OUTGOING PROP. STORAG �ti Tenn V-5 C NTACT COUNTER T160, STAIR #1 EAD PROC PRIVATE RIVATE FICE SHIER FFI. E (' s 2S,2V VESTIBULE QUEUING v- <7.) - 1 Flag Notes 1 Relocate Circuit End of Line Resistor from Existing Notification Appliance to this Device 2 Route Cable to New Audible Power Supply on this Level 3 Route Cable to Gutter Above Voice Evacuation Control Panel via Voice Riser in South Stair 9 Route Cable to Gutter Above Fire Alarm Control Panel 5 Mount SD on strut in front of damper centered at 18' for each 36' of width. After 72' add one SD for 6 No duct detector needed, area served has detection. each 24'. Sheet Note 1 Tap all Speakers at 1/4 Watt 25 Volts 2 Ambient 45dba as Listed in NFPA 72 A-4-3.2 All Audible Devices are set for 96 dba at 10' 3 Ambient Temperature is Between 65 and 80 degrees FIRST FLOOR PLAN SCALE'. 1/8" = 1 -4 N O col CC CO W CZ CO 1 -- CD J DESCRIPTION W Q a 04 0 z tV J KIJ Blvd. Sulfa 3 Lynnwood, Wa. 98036 4100 Alderwood Ma FAX (425) 697-2155 TEL (425) 697-2116 WASHINGTON LLJ J LJ a J 0 Cr LL1 z J 0 0 1 CE LL_ SCALE: AS NOTED PROJECT NUMBER: 1239 DRAWN BY: DME DESIGNED BY: TLB CHECKED BY: INITIALS DATE: 02/13/04 , SHEET I ALARM, L.L.C. ALL RIGHTS RESERVED. z 0 t!) U w 0_ >- m O N COPYRIGHT 16--Sep--2004 ATTORNEY OFFICE OFFICE 0.) PROJECTS LIBRA T24 FIL COP R WORK AREA N7-1 V-11 FILE/COPY STORAGE STORAGE 2085 2S,2V 2086 WAITING AREA 2125 R EMPLOYEE CORRIDOR 2099 N7-1 V-11 OFF1tE DISTRICT Es DIRECTOR R Tenn 2081 4-2 -6 2.80 'ORK ARE 2S,2V V-6 N4- i �V 1N4-1 N7-1 V-11 STORAGE T249 2S,2V IDOR s,v RAIS SUPV EL= ATOR BY 5 N4-2 V-6 0 E WORK AREA 2087 ES D STAIR :`2 D N4-2 V-6 ON O . ICE 7 FILE 1 S ORAGE 1 OFFICE SECURE STAIR :3 STORAGE SAVE OFFICES D,P N7-1 V-11 s o D 20'9 OFFICE heON FILE/ STORAG 2 DAO OFFICE 8 R 2S,2V 2S,2V STORAGE SUPV.' OFFICE VIS W N4 - V -6 T224 HALLWAY STORAG VI S WAI TOR ING 2027 SDAO OFFICE 23A0 OFFICE DAO OFFICE DAO OFFICE (T223j / FRAUD -OFFICE INTERVIEW N4-3 HALLWAY V-6 N4-3 V-6 4002 DAO OFFICE OFFICE REMOVE LAN CLOSET CONF./ TRAINING VISITOR WAITING D,2P.. .... N7-2 OPE ;r A/V TORAGE {T2851 ASYLUM ASYLUM OFFICE ASYLUM 2S,2V OFFICE DAO OFFICE DAO OFFIC DAO OFFICE R" 2112 S,V 6 DAO OFFICE T�11 DAO OFFICE T2OR 1, DAQ OFFICE T297 DAD OFFICE D DAO OFFICE 1 DAO OFFIC OFFICE DAO OFFICE SDAO OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE T294' OFFICE OFFICE Flag Notes 1 Relocate Circuit End of Line Resistor from Existing Notification Appliance 2 Route Cable to New Audible Power Supply on this Level 3 Route Cable to Gutter Above Voice Evacuation Control Panel via Voice Riser 4 Route Cable to Gutter Above Fire Alarm Control Panel 5 Mount SD on strut in front of damper centered at 18' for each 36' of width 6 No duct detector needed, area served has detection. to this Device in South Stair After 72' add one SD for each 24'. Sheet Note 1 Tap all Speakers at 1/4 Watt 25 Volts 2 Ambient 45dba as Listed in NFPA 72 A-4-3.2 All Audible Devices are set for 96 dba at 10' 3 Ambient Temperature is Between 65 and 80 degrees SECOND FLOOR PLAN 3/2 Gs N w EX m 04 L7D DESCRIPTION ARCHITECTURAL CHANGES CORRIDOR DETECTOR ADDITIONS 43 Q O CI 0 z 1 FAX (425) 697-2155 TEL. (425) 697-2116 WASHINGTON L1J J W U) J m .r� CD .rte z W H J CD0 LLJ CC SCALE: AS NOTED PROJECT NUMBER: 1239 DRAWN BY: DME DESIGNED BY: TLB CHECKED BY: INITIALS DATE: 02/13/04 SHEET FA -3 s s v OPEN :E tw- STAIR #1 203 Ii 111 i OPEN TO BELOW 1441 OFFICE REMOVE LAN CLOSET CONF./ TRAINING VISITOR WAITING D,2P.. .... N7-2 OPE ;r A/V TORAGE {T2851 ASYLUM ASYLUM OFFICE ASYLUM 2S,2V OFFICE DAO OFFICE DAO OFFIC DAO OFFICE R" 2112 S,V 6 DAO OFFICE T�11 DAO OFFICE T2OR 1, DAQ OFFICE T297 DAD OFFICE D DAO OFFICE 1 DAO OFFIC OFFICE DAO OFFICE SDAO OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE T294' OFFICE OFFICE Flag Notes 1 Relocate Circuit End of Line Resistor from Existing Notification Appliance 2 Route Cable to New Audible Power Supply on this Level 3 Route Cable to Gutter Above Voice Evacuation Control Panel via Voice Riser 4 Route Cable to Gutter Above Fire Alarm Control Panel 5 Mount SD on strut in front of damper centered at 18' for each 36' of width 6 No duct detector needed, area served has detection. to this Device in South Stair After 72' add one SD for each 24'. Sheet Note 1 Tap all Speakers at 1/4 Watt 25 Volts 2 Ambient 45dba as Listed in NFPA 72 A-4-3.2 All Audible Devices are set for 96 dba at 10' 3 Ambient Temperature is Between 65 and 80 degrees SECOND FLOOR PLAN 3/2 Gs N w EX m 04 L7D DESCRIPTION ARCHITECTURAL CHANGES CORRIDOR DETECTOR ADDITIONS 43 Q O CI 0 z 1 FAX (425) 697-2155 TEL. (425) 697-2116 WASHINGTON L1J J W U) J m .r� CD .rte z W H J CD0 LLJ CC SCALE: AS NOTED PROJECT NUMBER: 1239 DRAWN BY: DME DESIGNED BY: TLB CHECKED BY: INITIALS DATE: 02/13/04 SHEET FA -3 BY PRECISION ALARM, L.L.C. ALL COPYRIGHT ® 2004 16—Sep-2004 PLOT DATE: UTILITY STORAGE N5-1 V-7 77 Io°00000'�°1 TEt o5v s)® TREATMENT LINE OS 3009 Ea R 3119 WOMEN -D,P,2S,2V FITNESS ROOM N8-1 3045 IC APS8IA 3014 D,P 2AL UNIT ELEV. #5 N8-1 i V-12 TOILET 517 3007 ELEVATOR LOBBY 'D,P,2S,2V ELEV. #2 m- 2S,2V D,P,2S D,P _ STAIR 304 WOMEN'S LOCKER ROOM 71c11 -7 R 13QM 7 N8-1 V-12 STAIR #3 D,P,V CORRIDOR s,v D,P V-12 LAN CLOS T _T350 3049 PTI D,P Flag Notes 1 Relocate Circuit End of Line Resistor from Existing Notification Appliance to this Device 2 Route Cable to New Audible Power Supply on this Level 3 Route Cable to Gutter Above Voice Evacuation Control Panel via Voice Riser in South Stair 4 Route Cable to Gutter Above Fire Alarm Control Panel 5 Mount SO on strut in front of damper centered at 18' for each 36' of width. After 72' add 6 No duct detector needed, area served has detection. one SO for each 24'. Sheet Note 1 Tap all Speakers at 1/4 Watt 25 Volts 2 Ambient 45dba as Listed in NFPA 72 A-4-3.2 All Audible Devices are set for 96 dba at 10' 3 Ambient Temperature is Between 65 and 80 degrees THIRD FLOOR PLAN Q� SCALE:scn�1/8"= V-0" O\:7 REV. BY:I 1— S r fNO 1 DATE 1 DESCRIPTION ARCHITECTURAL CHANGES CORRIDOR DETECTOR ADDITIONS 04 C•4 t` CO d d r cel Z O FAX (425) 697-2155 TEL. (425) 697-2116 12500 TUKWILA INTERNATIONAL BLVD SEATTLE CC LL r SCALE: AS NOTED 1 PROJECT NUMBER: 1239 DRAWN BY: DME DESIGNED BY: TLB CHECKED BY: INITIALS DATE: 02/13/04 j SHEET FA >- m 0 PUBLIC AFFAIRS PUBLIC ' `1A F FA I R S FIELD CONFERENCE DEPUTY DIRECTOR FIELD COMPUTER COMPUTER DIRECTOR MANIGtR 3062R 2V ES N5-4 R 2S OP 5 4 R-E8A 1111.1 OPEN WORK AREA N5-4 V-8 SPEC ASSIST R D ES 3079 N9-1 V-13 3059 CORRIDOR 3078 V-13 ES 3080 V-13 CORRIDOR 3082 DO OFFICE PY FILE DRAG E 7432 R D WAITING DT E L. 3058 ADP ' EPAIR 2S,2V 2S,2V 3087 R 3086 rR •• D 00.60000 0.00000 2S,2V 3021 0 3066 D 3065 SERV R R00 ELEV. 42 BY ,P,2S OFFICE 3068 D STAIR #2 STORAGE 3100 R.. STAIR #3 DO OFFICE R 3104 3105 N9-1 V-13 OPEN W$RK AREA 311 ROOM JOINT USE FIREARMS/ AMMO STORAGE T41374 RJOINT ONFE DO OFFICE INTERVIEW ROOM USE3098 ENCE TRAI ING T4 D - N9-3 V-13 --Fig 'RT 3026 OFITICE OFFICE T481 DO OFFICE WORKN5AREA TY .: T483 COMMUNICA DO OFFICE OPE WORK A 1\1■■■■■■■■■■■%1 1■\`\■■■■■■■■■■1 1■■1010■■■■■M■■■■1 1■1011■■\■■►.11■■■■1 1■■■■■►111011■■■■■1 otriimmnnmousumisis OFFICE OFFICE DO OFFICE DO OFFICE DO OFFICE DO OFFICE OFFICE OFFICE OFFICE OFFICE DO OFFICE DO OFFICE DO OFFICE T495) DO OFFICE 1U/■■■■■U■■■11I1 111\■■■■■U■■■4■1 1111■\\11■■■■■EE■■1 1■■■■\■■■1111/.%■■■1 1■■■■■\1010►�■■■■1 1■■■■■■EMEIM■■■■1 1■■■ENI■■■•\S■■■1 1■IN%■■■■■■■■\E111 vrammi ....sio..... 16—Sep-2004 PLOT DATE: Flag Notes 1 Relocate Circuit End of Line Resistor from Existing Notification Appliance 2 Route Cable to New Audible Power Supply on this Level 3 Route Cable to Gutter Above Voice Evacuation Control Panel via Voice Riser 4 Route Cable to Gutter Above Fire Alarm Control Panel 5 Mount SD on strut in front of damper centered at 18' for each 36' of width 6 No duct detector needed, area served has detection. to this Device in South Stair After 72' add one SD for each 24'. Sheet Note 1 Tap all Speakers at 1/4 Watt 25 Volts 2 Ambient 45dba as Listed in NFPA 72 A-4-3.2 All Audible Devices are set for 96 dba at 10' 3 Ambient Temperature is Between 65 and 80 degrees FOURTH FLOOR PLAN e SCALE: 1/8" = 1'-0" CO W CZ TLB I TLB (NO 1 DATE 1 DESCRIPTION ARCHITECTURAL CHANGES I CORRIDOR DETECTOR ADDITIONS 05/24/04 108/24/04 Blvd, Suite 3 Lynnwood, Wam, 98036 4100 Aldenaood M FAX (425) 697-2155 CFI Tri WASHINGTON 12500 TUKWILA INTERNATIONAL BLVD SEATTLE im C SCALE: AS NOTED 1 PROJECT NUMBER: 1239 DRAWN BY: DME DESIGNED BY: TLB CHECKED BY: INITIALS DATE: 02/13/04 J SHEET FA -5 16--Sep--2004 PLOT DATE: 5-4 • • DATA LOOP 3 P-3 B224RB TO FACP * VERIFY SHEILDING REQUIREMENTS WITH WIRE LEGEND SHIELD DRAIN TO DOOR STRIKE (VERIFY WIRING REQUIREMENTS AT DOOR STRIKE) �_ SHIELD -� DRAIN TO NEXT DEVICE INTELLIGENT DETECTOR RELAY BASE DETAIL SCALE: NONE RISER DIAGRAM SCALE: NONE m> to v -a T - - - - 5 ARCHITECTURAL CHANGES CORRIDOR DETECTOR ADDITIONS ROOF • D,P D • 105/24/04 osiza/oa R •r v V-13 S • EOLR R Q �9 1�" r I S S S 5 S S S S N9-1 CNI RQ G D •DATA LOOP 3 N9-3 Q� Q Q N9-2 Q C © fl MIC DM DM F V V V V V •r 2S,2V D D D D D D O PS -9 D,2P V IC • • y V-8 S S S O ■ ■ ■ • Q • Q : Q N5-4 • 2V .. V V s S V S N5-3 • V-8 V 2V 4TH FLOOR S .. D D,P �� R V-12 • EOLR R O D t9 1iy I : S S - N8-2 •• o S R R D G DATA LOOP 3 Q�Q© QQ�:i© MIC DM DM F V V V D D D D D D,2P D O PS -8 V IC UAPS_4� IC O V-7 S S S N5-1 IC 3V Q��Q ■ ■ ■ 110VAC v • S v S S v V V N5-2 : ■ ■ V Q Q QCi Ku mi m immui■ V-7 • • 2v 2v v 3RD FLOOR D r DATA LOOP 4 : V-11 D 2D,P . S S EOLR R OO O 0 6R /. /; v* D N7-2 DM F V V V M D IC D DM D D D,2P D/ D PS -7 DATA LOOP 2 V Y v 2S 2S 2S N4-3 © N4-3 S,V S Q Q ■ V-6 2S 2V 2S 25 2V S V S V .. SV ■ N4-1 © Q::: DATA LOOP 2 O2S -6 .1r 2V 2S 2S 2V V S V S 4V N4-2 Q ; Q ; Q ; ■ ■ ■ APS 4 IC 11OVAC V-6 ► V-6 2V 2V 2ND FLOOR 2D,P ,. V-1 Q S S S S S N6-2 N6-1 • • v v V v A'S -6 D,P D D ,► D,2P ® r II tO EOLR $ R R r : : D D,P D v D,P D,P D,P DATA LOOP 2 D,P 2N,P • V-5 OM : IC IC : r : F : O ; GUTTER J -BOX : ANN S S S w N3-1 S■ S■ S 441,: Q lehriaIC V S APS -3 2V 2V .. Vy S S S N3-2 V GRAPHIC : Q: Q: ■ FACP AMPLIFIER SMOKE V-5 2S 2V 2S 2S 2V DCD DEDICATED CONTROL ANN N3-3 S S■ S 120VAC BATTERIES © Q Q ■ • V-5 ' • N3-3 2V 2V I- a 0 0 J Q Q 0 1ST FLOOR i D,P D,P 7 .• D,3V EOLR F : D P : EOLR V4 ELEVATO CAB R D P D,P D,P I D,P : ae DM : IC D,P $ IC L- © : r : F : IIC V O 1 1 OVAC APS ■ ■ N2-1 -2 ='■ ■ N2-2 J .. .r _ P-1 D,2V S • V-3 N1 -3 ■ ■ ■ ■ ■ N1-4 V-2 V2 2S,V , 2S,V.. 2S,V .kvM- D D D R R .► x: x : x : O 2S,V 2S,V v 2S,V .: �. V2 I F: x v x ,•x S P-2 N1-1 2S 2V N1-2 : S N1-3 V' D,VS N1-1 V 41• • : • .... • 2S,2V N1-3 V-1 V-1 $ .r J .r D D ■ • • N1-4 IF 0 r IC APS-1110VAC D I ,> OA V D _ • r M t, P-3 B224RB TO FACP * VERIFY SHEILDING REQUIREMENTS WITH WIRE LEGEND SHIELD DRAIN TO DOOR STRIKE (VERIFY WIRING REQUIREMENTS AT DOOR STRIKE) �_ SHIELD -� DRAIN TO NEXT DEVICE INTELLIGENT DETECTOR RELAY BASE DETAIL SCALE: NONE RISER DIAGRAM SCALE: NONE m> to TLB 1 TLB DESCRIPTION ARCHITECTURAL CHANGES CORRIDOR DETECTOR ADDITIONS lad 105/24/04 osiza/oa I- 0 CNI w M114 Blvd, Suite 3 Lynnwood, Wa. 98036 4100 Alderwood Mal FAX (425) 697-2155 TEL. (425) 697-2116 DEPARTMENT OF HOMELAND SECURITY T WASHINGTON LU —J F— F— LU cn D CO CC W 2 LO CC H LL SCALE: AS NOTED PROJECT NUMBER: 1239 DRAWN DESIGNED BY: BY: DME TLB CHECKED BY: INITIALS DATE: 02/13/04 r --AREA OF WORK Sri App f�tff�r�r1 Cc=rtt VICINITY MAP SCALE'. NTS r AREA OF WORK =0:1011 C1121121 11=== =11101 1101111011 =01 =1 =1 11112=111 =01 =10022 1=01 NEW OFFICE 2 AREA OF WORK u u r1.:°.:.:. BUILDING MAP SCALE: NTS NEW OFFICE 3' ISTIN ARE .R COV RAGE HROUGHOUT SIDE RK AR A 3RD FLOOR USCIS D20 OFFICE REVISIONS SCALE'. 1/4" = 7'-0 LI EXISTING BRANCH LINE PIPE TYPICAL GENERAL NOTES: 1. SYSTEM DESIGNED PER N.F.P.A. #13 STANDARDS. 2. ALL SYSTEM COMPONENTS U.L. LISTED AND/OR F.M. APPROVED. 3. SCOPE OF WORK IS TO MODIFY EXISTING FIRE SPRINKLER HEADS IN OFFICE AREA TO ACCOMMODATE TENANT IMPROVEMENTS. OCCUPANCY CLASSIFICATIONS DO NOT CHANGE. 4. UTILIZE FLEX HEADS FOR RELOCATED OR ADDED SPRINKLERS. 5. EXISTING AREAS ARE SPRINKLERED (SPRINKLERS NOT SHOWN). SY R E BOL LEGEND RELOCATE "p " EXISTING HEAD TO NEW "0" LOCATION, SEE DETAIL 1. EXISTING HEAD NOT RELOCATED DETAIL 1: REPLACEMENT OF SPRINKLER (TYPICAL) MAIN LINE (EXISTING) BRANCH LINE (EXISTING) ,--- 1" DROP (EXISTING) FLEX ARM (NEW) PENDENT SPRINKLER (NEVV) Pit Ygr*45 773 141 .7r 0 Without Comments As Noted in Red Per The Attached Letter .f hese plans have been reviewed by The Tukwila Fire revention Bureau for conformance with current City dards. Accepl;air . is subject to errors and ,r-nissions which do not authorize violations of adopted -:.t..zinciards and ordil;-i: c4 ., The responsibility for the ;adequacy of desigr! I :; r. , t:.:ttally with the designer. 4,ciditions, deletions or r talion s to these drawings after this date will void this :Eicceptance and will require a resubrnittal of revised drawirtc;s for subsequent approval. Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: 13 71 By: /c��• s" l t DEPARTMENT 206-5-PS.i-4Ji07 E'tvc thisua(�r�lf er e t !O. f3cxactt'v rtz'. liar shut owri or rtstcv' cion approval 0 5 10 SCALE IN FEET PAID 11 2015 TUKWILA FIRE cc '0) • .RM w •• WASHINGTON STATE�asswwri�.w7 CERTIFICATE OF COMPETENCY FIRE !PROTECTION SPRINKLE* KYMTEI Kevin P. Jensen 4355-06013-C Leve! S Reliance Fire Protection. Inc R IAFP102L1 02/04/15 1 1 NOTES Symbol Legend Description Revisions Sprinkler Legend Revision No. Description Symbol Manufacturer Model FINISH K Factor Degree 2 WAY EQ BRACE 4 WAY EQ BRACE GLOBE GL5601 QR PENDENT WHITE 5.6 155 Qty. 3 0 RIGID GROOVED COUPLING 0 FLEXIBLE GROOVED COUPLING NEW SPRINKLER PIPING EXISTING SPRINKLER PIPING HANGER LOCATION 3 CONTRACTOR'S LICENSE: Lic. # RELIAFP 102L1 S01135 Date: FEB 2015 Reliance Fire Protection Inc., Tel: (206) 682-6636 PO Box 428 Fax: (206)682-6744 e-mail: kevin@reliancefire.com Preston, VVA 98050 Drawn by: K. JENSEN Approval: CITY OF TUKWILA Scale: AS SHOWN USCIS D20 OFFICE REVISIONS 3RD FLOOR 12500 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 SHEET # FP 01 FIRE PROTECTION SPG KLHH D� A CONCRETE DECK HILTI HDI -P DROP-IN ANCHOR 3( ATR TOLCO FIG. 25 SURGE RESTRAINER INSTALLED AT END OF EACH BRANCH LINE 3/8"ATR @ 1" TO 4" PIPING SWIVEL RING PIPE TO BE BRACED HANGER - CONCRETE (FOR 3" PIPE AND SMALLER) BRANCHLINE STRUCTURE HANGER (tFREQUIRED) 1" x ARMOVER (SEE PLAN) CORRUGATED STAINLESS STEEL HOSE ADJUSTABLE HUB SUSPENDED CEILING EXPANSION PLATES ARE NOT REQUIRED WHERE FLEXIBLE TYPE SPRINKLERS ARE INSTALLED FLEXIBLE SPRINKLER HEAD DETAIL o Without Comments o As Noted in Red $ Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current !City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted s_andards and ordinances. The responsibility for the adequacy of design rests toMily with the designer. Additions, deletions or revisions to these drawings after this date wil! void this acceptance and will require a resubmittal of revised drawings for subsequent approval. :incl acceptance Is subject to field test and inspection. by The Tukwila Fire Prevention Bureau. Date: /1- 30-1 a - By: TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Pert ifs[ No. la-s-Ol�j exact address for shut- down hutauwn or restoration approval. CL\HHA \0 1. SPRINKLER SYSTEM DESIGN PER N.F.P.A. #13 2. ALL MATERIALS SHALL BE NEW AND U.L. LISTED OR F.M. APPROVED 3. FIRE SPRINKLER SYSTEM TO BE INSTALLED, HUNG, BRACED AND TESTED IN ACCORDANCE WITH N.F.P.A. #13 4. IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT IS THE OWNERS RESPONSIBILITY TO PROVIDE HEAT THROUGHOUT THE WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE, DELUGE AND OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS 5. FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE SPRINKLER SYSTEM. 6. ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING OR PATCHING TO BE BY OTHERS. 7. NEW AND RELOCATED SPRINKLER HEADS ARE TO BE ON 1" DYNATHREAD OR SCHEDULE 40 ARM OVERS. 8. NEW MAINS AND NEW BRANCH LINES ARE TO MATCH EXISTING PIPE SIZING WHERE HYDRAULIC CALCULATIONS ARE NOT REQUIRED. 9. SPRINKLER HEADS HAVE BEEN ADDED AND RELOCATED TO ACCOMMODATE TENANT IMPROVEMENTS. AREAS OUTSIDE SCOPE OF WORK ARE TO REMAIN. 10. THE OWNER IS RESPONSIBLE FOR THE PERIODIC INSPECTION, TESTING, AND MAINTENANCE OF THESE FIRE SPRINKLER SYSTEMS IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 25 1995 EDITION. THIS WORK MUST BE DONE BY QUALIFIED PERSONNEL STARTING AFTER THE WARRANTY PERIOD HAS EXPIRED. THE COMPANY THAT DESIGNED AND INSTALLED THIS SYSTEM IS THE BEST QUALIFIED TO PROVIDE THE ONGOING LONG TERM TESTING, SERVICING, AND MAINTENANCE OF THIS SYSTEM(S). SCOPE WOH 1. ADD NEW RECESSED PENDENT SPRINKLERS INTO NEW CEILING GRID TO ACCOMMODATE TENANT IMPROVEMENTS. 2. NEW SPRINKLERS SHALL BE QUICK RESPONSE, STANDARD SPRAY, RECESSED, PENDENT SPRINKLERS RATED AT 155°F & 5.6k. 3. ALL AREAS DESIGNED TO ORDINARY HAZARD OCCUPANCY U.N.O. 4. UPRIGHT PROTECTION IS NOT REQUIRED ABOVE CEILING. 5. ALL AREAS OUTSIDE SCOPE OF WORK ARE TO REMAIN AS IS AND UNAFFECTED BY TENANT IMPROVEMENT. SPR KLHH v ® PENDENT SPRINKLER O UPRIGHT SPRINKLER % SPECIAL APPLICATION PENDENT SPRINKLER SPECIAL APPLICATION UPRIGHT SPRINKLER PENDENT AND UPRIGHT SPRINKLER ® CONCEALED SPRINKLER EXTENDED COVERAGE CONCEALED SPRINKLER EXTENDED COVERAGE PENDENT SPRINKLER SIDEWALL SPRINKLER DRY SIDEWALL SPRINKLER ® DRY PENDENT SPRINKLER 4( DRY EXTENDED COV. PENDENT SPRINKLER RELOCATE SPRINKLER ADD SPRINKLER ®P PLUG OUTLET a SPRINKLER PIPE CAP a SPRINKLER PIPE DROP o SPRINKLER PIPE RISE EXISTING SPRINKLER PIPING --- NEW SPRINKLER PIPING * SEE SPRINKLER LEGEND FOR SPECIFIC SPRINKLER TYPES v p LA\ * \OP N OFFICE AR rtttl PROTECTION NOT EXISTING SPRI\KLERS TO REMAIN AT 1 • 0 0 21 2 0' 1' 4' 8' 15' eTh SPRINKLER PLAN — LEVEL 4 USE INST SPRI CEILI SPRINKLER LEGEND EXISTING OUTLETS TO LL FLEXHEAD TYPE KLERS INTO NEW NG GRID (TYPICAL) SYM TYPE COLOR ESC RESPONSE TEMP K NPT MFG. MODEL # ID # QTY 0 EXISTING SSU BRASS - QR 155°F 5.6 W TYCO FRB TY3131 - 0 EXISTING SSP CHROME CHROME QR 155°F 5.6 W TYCO FRB TY3231 - eN ADD REC SSP CHROME CHROME QR 155°F 5.6 W TYCO FRB TY3231 31 1P PLUGGED HEADS 0 TOTAL AFFECTED 31 ri mstry FIRE PROTECTION 5005 3RD AVE SOUTH SEATTLE, WA. 98124 (206) 762 - 3311 PORTLAND: 12021 NE AIRPORT WAY, SUITE G PORTLAND, OR 97220 (503) 331 - 0234 PROJECT: U.S. DEPARTMENT OF HOMELAND SECURITY ICE - DHS TENANT IMPROVEMENT LEVEL 4 12500 TUKWILA 1NT'L BLVD TUKWILA, WA 98168 1 01.23.12 FP ISSUE FOR PERMIT NO. DATE DESCRIPTION McKINSTRY DIVISION: FIRE PROTECTION DESIGNED BY: JES - 206.396.8528 DRAWN BY: JES CHECKED BY: JSS JOB NUMBER: McK # 1914 DATE: 01.23.12 SHEET TITLE: ICE DEPT OF HOMELAND SECURITY SPRINKLER PLAN LEVEL 4 SHEET NUMBER: FP -L04 -T1 •_ I Ce ■ IRDI [■ I NM 0.). Ca MEI - EMI Eirmai oviii-021 vIlI EU Ei -MEM ■i =MI 111110-4"6 'a Mil mime mamas MEE. ramm �w,wwwlwwrttr+zt�l�lt�: ■r�>,r�lar.�7�. LVIm i�■1�1�1r1�! l■ .1111111111/2 r0 131 IIl'IEIi1 ®�°r ri NEM MEM El MIN 111111111.1111 rhea emem�� o....�w:i �:�► -a��t'It �� �;/SII•-- C�Ii112' 4 REFLECTED CEILING PLAN 1, II = 1 9 _ On �J 3/32 Design per NFPA 13 - Ordinary Hazard Occupancy -130 sq ft per sprinkler All materials to be new, U.L. listed, and F.M. approved All heads to be a minimum of 6' apart and to be unobstructed by any means • 39 -Add Reliable Model FIFR Quick Response Sprinkler Heads 155° 1/2 x1/2 • Removing stub -up with upright heads to put pendent heads in 39 - Total "Automatic" Sprinkler Corporation of America No. 12 Concrete Hangers ▪ Hanger Rings / Anchors: UL Listed & FM Approved Hanger Rods: Comply with NFPA 13 ❑ All Thread Rods 0 Machine Thread Rods Finishes: ❑ Standard Components HANGERS C 2.27 0 All Galvanized Components 1"=25.4 mm Components 1. Drop-in Anchor 2. Spring Clip Ceiling Plate (optional) 3. Hanger Rod 4. Adjustable Hanger Ring Application / Description No. 12 Hangers are designed to support piping under smooth or flat concrete slab construction. They utilize an anchor that is set flush in a hole predrilled in the concrete, then expanded against the sides of the hole with an internal plug. NFPA 13 terms this type of fastener an "expansion shield". In "Automatic's" data, however, the manufac- turer's nomenclature is used. It is called a drop-in anchor. There are 3 components in a basic No. 12 Hanger: The drop-in anchor, a threaded rod and an adjustable hanger ring. The rod may be either all thread rod (ATR) or ma- chine thread rod (MIR). All thread rod is considered to be standard, however. As a rule, machine thread rod is pro- vided only when it is a specific requirement of the job specifications. As an option, the hanger may be furnished with a spring clip ceiling plate when a more finished appearance is needed in an area. NFPA Requirements / Limitations NFPA 13 has specific requirements and/or limitations 1 's2 for the use of expansion shields (drop-in anchors) when they are installed in the vertical position. The standard reads: . . . In concrete having gravel or crushed stone aggregate, expansion shields may be used in the vertical position to support pipe 4" or less in dia- meter. For the support of, pipes 5" and larger, expansion shields if used in the vertical position shall alternate with hangers connected directly to the structural members such as trusses• and girders, or to the sides of concrete .beams. In the absence of convenient structural members, pipes 5" and larger may be sup- • ported entirely by expansion shie/ds in the vertical position, but spaced not more than 10 ft (3 m) apart. Expansion shields shall not be used in ceilings of gypsum or similar soft material. In cinder concrete, expansion shields shall not be used except on branch lines where they shall alternate with through bolts or hangers attached to beams. SW = Segmentaly weideii steel • (d)'4 Ductile iron Madel MT -3 & MT -9 Mechanical tee serves the same function as MT -1 & MT -8 but use a steel electro prated u -bolt to save space and for easier installation In tight places. It is ideal .for direct connections with sprinkler heads. and drop nipples. HOUSING: Ductile iron ASTM A536 grade 85-45-12. COATING: Zinc electroplated - U - BOLT: Carbon steel SAE grade 2, zinc plated. NUT: Carbon steel ASTM A194, zinc plated. GASKET: EPDM (-30°F to 4 230°F) THREADS: MT -3 NPT per ANSI/ASME 81.20.1 MT -9 British standard parallel (BSP) per 9521 MT,•3'8c<IViT NOMINAL 7123 IN. • ... � 9IECHANIC MAX, 170511149 9.9.1.1 ... .,,. �.• 11 .Re 711! IN. LT` ...... ... ..... r t �� t x2RV 4 u,m'.3 f .i,}ar.#@,#ta3`:gg °1YIIN11oN74nrn,.,, • - A9910%. 9,113111 EACH L•1:.. . 6 C o , 5 1 114112.300 11/4/93/4 300 1.19 2,14 1:64 3.50 1.31 2' ,Zi • 0,93 1.19. 2.74 1,64 3.50 121 2.26 0.97 1 1141 1 300 1,19 227 1.61 3.30 1,31 3.25. 1.08 912912 300 7,19 2,29 1.78 3,50 1,23 226 0.63 11213/4 300 I 1.19 2.25 1.76 7.50 1.33 2.25 0.07 1 0.217 700 1.19 2.39 1.73 ft 3,^90 773 2.25 1.9s '� 2 s 1/2 :100 1.10 2.51 2.01 " 3.73 1,36 2,76 0.97 2 9 a/A _I 2 t 1 300 1.75 _._.. 0..:..w 39>D�--�I.10 2.51 2.54 2.01 3.70 ---1'37,'---311-"---1:60*-- 1.95 2.25 • 2.25 0.50 .... 3.09 -] t,gx :1.75 2 12 1 113 2,...__" 300 • 1.19 ' 74 2,30 4.21 1.61 1 31/2 s 314 300 1.19 2.76 2.25 4.20 1.1(1 1 3.15 0.20 2 112 5 1 300 1.19 , 3.54 2.22 7.32 •1.35 •1.79 1 91 V.25 1- . 1.14 313.0.a 1/2 300 1.19 292 1 _I Um' 2.95 2.21 . 059 0.10 -- 106.0.1314 _- ,.75.a :i-r...��_._._..1.10 300 1.19 292 2.;92 -11,9- 4.35 4.20 1.911 ,I-1-----i.-2T-7-r----ix,---:1 2.95 Sim" `+7 1'9C.i1 O Without Comments a As noted in Red ' gf Per The Attached . Letter mese plans have t-een reviewed by The Tukwila Fire •:,'ention Bureau for conformance with current City idards. Acceptance is subject to errors and 'i.5sions which do not authorize violations of adopted rldards and ordinances. The responsibility for the :gtiacy of design rests totally with the designer. cl tir.ns, deletions or revisions to these drawingsaafter tuts dte will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. - * A'6ovc Ce71,h5 greti t,,1.�7 tor+, t� w. Nw 13 Sec .g 1 Or .SPrt`�ICI�re�1. 1i KWtL4 FIRE DEPAtill.tuoils Please call: 575.4107 and give this job No. /0-8-07.3 and exact address for shut. '111wr] or restoratian approval NOTICE Weld stamps must be inspected before pipe is hung. P_Q_Dat paint piping prior to hydrostatic test approval. CROWN FIRE PROTECTION INCORPORATED. P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7889 OCIO 12500 Tukwila International Blvd Tukwila . WA MA'i TUK. PAID . 7 2010' WILA FIRE c DATE:, - DRAWN: i SCALE: ',�)2 " / STRUCTURE -� HDIP -� 1" x ARMOVER SEE PLAN SUSPENDED CEILING PENDENT HEAD RELOCATE DETAIL " x ARMOVER BRANCHUNE SUSPENDED CEILING PENDENT HEAD RETURN BEND DETAIL.. KEY PLAN EXISTING SPRINKLER PIPING NEW MAIN SPRINKLER PIPING NEW BRANCHLINE SPRINKLER PIPING NOTES 1. MODIFY EXISTING SPRINKLER SYSTEM TO ACCOMODATE NEW WALLS AND CEILINGS. 2. EXISTING UPRIGHT SPRINKLERS TO REMAIN IN ROOMS WITH NO CEILINGS. 3. 1" PIPE TO BE SCHEDULE 40 WITH BCI FITTINGS. PIPE VA" THROUGH 2" SHALL BE DYNATHREAD WITH BCI FITTINGS. 4. REVISED PIPE TO MATCH EXISTING SPRINKLER SYSTEM SIZING. GENERAL NOTES 1. SPRINKLER SYSTEM DESIGN PER N.F.P.A..#13 2. ALL MATERIALS SHALL BE NEW AND. U.L. -LISTLO .OR F.M. APPROVED 3. FIRE SPRINKLER SYSTEM TO_ BE INSTALLED, HUNG, BRACED AND TESTED IN ACCORDANCE WITH N.F.P.A.. #13 4. IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT IS THE OWNERS RESPONSIBILITYY. TO PROVIDE HEAT THROUGHOUT THE WET PIPE SPRINKLER SYSTEM AREAS. AND IN. ENCLOSURES FOR DRY PIPE, DELUGE AND OTHER TYPES OF VALVES . CONTROLUNG WATER SUPPIJES TO SPRINKLER SYSTEMS 5. FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE SPRINKLER SYSTEM. 6. ALL ELECTRICAL, PAINTING : OF PIPE, FURRING, CUTTING OR . PATCHING TO BE BY OTHERS. 7. SPRINKLER HEADS ARE NOT NECESSARILY LOCATED IN CENTER POINT OR QUARTER POINT OF CEIUNG TILE, UNLESS NOTED OTHERWISE 8. RELOCATED . HEADS ARE ON 1" SCH.40 ARM: OVERS.. ADDED HEADS AND NEW BRANCH ONES • ARE TO MATCH . EXISTING PIPE SIZING. 9. SPRINKLER HEADS ADDED AND RELOCATED TO. ACCOMMODATE TENANT IMPROVEMENTS. AREAS . OUTSIDE- SCOPE OF WORK ARE TO REMAIN. 10. THE OWNER IS RESPONSIBLE FOR 'THE PERIODIC INSPECTION, TESTING, AND MAINTENANCE OF. THESE FIRE SPRINKLER; SYSTEMS IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 25. 1995 EDITION. THIS WORK MUST BE DONE BY QUALIFIED PERSONNEL STARTING AFTER THE WARRANTY PERIOD HAS EXPIRED. THE COMPANY THAT .DESIGNED AND INSTALLED THIS SYSTEM IS THE BEST QUALIFIED TO PROVIDE THE . ONGOING . LONG TERM TESTING, SERVICING, AND MAINTENANCE OF 11 -HS SYSTEM(S).. to Of . Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800-669-6223 PORTLAND: 2021 NE AIRPORT WAY, . SUITE G PORTLAND, OR 97220 503-331-0234 www.mckinstry.com CIS .GROUP TENANT DEPARTMENT OF HOMELAND SECURITY BUILDING 111211)•eeeeeeee/Irl eee\MoeeMeTIII/ ..1 ■eer�ee► fr:�ee/well ee/ramoirc4 Lmon iii.■_eeeeeeeeef■_.e >�mr �riamr ;• Aiiiir 'al-.�-'�.iimrri�rs�ii G��Itii MMIU s11111111111 1lelti ae111KINI •eee llee►_t—../eeeee_\ee mer�..neminsimoiofir.E. lancrammhzimmersamorAmlamorammIaminniMsionar ..1 2Y _2v2 Weld stamps must be inspected before pipe is hung. iiQ paint piping prior to hydrostatic test approval. 12500 TUKWILA 1NT. BLVD. TUKWILA, WA 98168 ACCEPTS Without Comments As Noted In Red. Per The attached Letter These plans have been reviewed by.The Tukwila Fire • Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the 1. adequacy of design rests totally with the designer. Additions, deletions or revisior.s to these drawings after this date wilt void -this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: c l -b 9 By: 51_1. VESf1BUlE 1 301] it/moi it 11eMMrallu_ ran= A € ; r 1- NI ikri lammi r I 1 Iia :. MSIriumon le/ NEM /AIMram/ gloom"! tutomtA FIRE DEfoiWuall. Please call: 575.7 and give this job No. 6°1 =S—o� and exact address for shut■ (gown or restoration a r e� ' NM / NMII NE Iril r4 ISM II ' II ■ EIt ■■ e>. �`•I � MEI CI >.�['iCi7fi�oi �L!%i%eF► Re�ei :I D REGISTRATION: cs REVISIONS: 1 NO. DATE DESCRIPTION McKINSTRY . DIVISION: FIRE .PROTECTION zO Level 3 - Tenant Improvement SCALE: 1/8u =1'-0" HEADS ARE TO BE SPACED CENTER OF TILE SPRINKLER LEGEND SYM TYPE COLOR ESC RESPONSE UTEMP K NPT MFG. MODEL # iD # QTY ®* SSP CHROME CHROME QR 155 5.6 1/2 TYCO TY -FRB TY3231 46 O+` SSU BRASS . - QR 155 5.6 1/2 TYCO. . TY -FRB TY3131 9 4P PLUGGED HEADS S TOTAL 55 DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: SHEET TITLE:. CIS GROUP TENANT DEPARTMENT OF HOMELAND. SECURITY BUILDING JAY.BEAKMAN 206 JB.. 8438 SCOTT SPITZER. SHEET NUMBER: FP -3 " x ARMOVER BRANCHLINE SUSPENDED CEILING PENDENT.: HEAD RETURN BEND DETAIL KEY PLAN EXISTING SPRINKLER PIPING NEW MAIN SPRINKLER PIPING NEW BRANCHLINE SPRINKLER PIPING NOTES. 1. MODIFY EXISTING SPRINKLER SYSTEM TO ACCOMODATE NEW WALLS AND CEILINGS. 2. EXISTING UPRIGHT SPRINKLERS TO REMAIN IN ROOMS WITH NO CEILINGS. . 3. ` 1 PIPE TO BE SCHEDULE 40 WITH BCI FITTINGS. PIPE 1W THROUGH T SHALL BE DYNATHREAD WITH BCI FITTINGS: 4. REVISED PIPE TO MATCH EXISTING SPRINKLER SYSTEM SIZING. GENERRL NOTES 1. SPRINKLER SYSTEM .DESIGN PER N.F.P.A. #13 2. PLL MATERIALS SHALL BE NEW AND. U.L LISTED OR F.M. APPROVED 3. FIRE SPRINKLER SYSTEM TO BE INSTALLED, HUNG, BRACED AND TESTED IN ACCORDANCE WITH N.F.P.A. #13 4. IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT THE OWNERS RESPONSIBILITY TO PROVIDE HEAT THROUGHOUT THE WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE, DELUGE AND OTHER TYPES OF VALVES CONTROWNG WATER SUPPLIES TO SPRINKLER. SYSTEMS 5. FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE • TO ADEQUATELY SUPPORT THE FIRE SPRINKLER SYSTEM. 6. • ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING OR PATCHING TO BE BY OTHERS. 7. SPRINKLER HEADS ARE NOT NECESSARILY LOCATED IN CENTER POINT OR QUARTER POINT OF CEILING TILE, UNLESS NOTED OTHERWISE 8. RELOCATED HEADS ARE ON 1" SCH.40 ARM OVERS. ADDED. HEADS AND NEW BRANCH LINES ARE TO .MATCH EXISTING PIPE SIZING. . 9. SPRINKLER HEADS ADDED AND RELOCATED TO ACCOMMODATE TENANT IMPROVEMENTS. AREAS. OUTSIDE SCOPE. OF .WORK ARE TO REMAIN. 10. THE OWNER IS RESPONSIBLE FOR THE PERIODIC INSPECTION, . TESTING, AND MAINTENANCE OF THESE FIRE SPRINKLER . SYSTEMS IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 25 1995 EDITION. THIS WORK MUST BE DONE BY QUALIFIED: PERSONNEL STARTING AFTER THE WARRANTY PERIOD HAS EXPIRED. THE COMPANY. THAT. DESIGNED AND INSTALLED THIS SYSTEM IS THE BEST. QUAUFIED TO PROVIDE THE ONGOING .LONG TERM TESTING, SERVICING, AND. MAINTENANCE OF THIS SYSTEM(S): instiy ife Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800-669-6223 PORTLAND: 12021 NE AIRPORT WAY,SUITE G PORTLAND, OR 97220 503-331-0234 www.mckinstry.com PROJECT: ICE TENANT IMPROVEMENT `DEPARTMENT OF HOMELAND' A SECURITY BUILDING CEILING GRID SHOO FOR CONTINUATION ONLY, TILE WILL NOT BE INSTALLED UPRIGHT SPRINKLER PROTECTION ONLY PROVIDED IN EMPTY TENANT SPACE O. VA „ANT 51TE 41111 / � inrrva.................. ��an.�rar..rarrca�.rrru 441/ wir par -Awer-- A.FairAprma AiAir „Tr , a „firerr-_- Tor acro: frueznamorow, ray Al A "PM i ATIFAVIPT ARA4:47. . 4 1 I r r . Fr /1111911rAi r .-..,.:.,.,...••:, Itiri!�._. �_HT • rs'' 'ry GfQrss ��� � I ; mow • --i :: .!fr; ail i II Mir 01WM AI Air Air AderrAllp I ‘01-v'of &/C1/01 0,141 • ''•=11=M:=W.MII=M=N=7' .i4M=M=M=V" Arr AWM wrAi 2 a 1 fVco co Q a. oooo co LL_ N . co 2 rno . o Ia ti. U m a DESIGNED BY: DRAWN BY:. CHECKED BY: JOB NUMBER: DATE: SCALE: FIRE PROTECTION JAY BEAKMAN 206-832-8438 JB SCOTT SPITZER SHEET TITLE: ICE TENANT IMPROVEMENT DEPARTMENT OF HOMELAND SECURITY BUILDING HEADSARE TO BE SPACED CENTER OF TILE SPRINKLER LEGEND SYM • TYPE .. • COLOR • ESC RESPONSE TEMP K • NPT MFG. • MODEL # ID # • QTY 01' • SSP • CHROME CHROME QR.. 155 5.6 1/2 TYCO TY -FRB TY3231 . 35 V. SSU BRASS - QR ::155 .5.6 112 TYCO. TY -FRB . TY3131 • :4 OR . SSU BRASS. . - • QR .: 1.55. 5.6 112 • TYCO . • TY -FRB TY3131 2 PLUGGED HEADS 2 TOTAL 41 SHEET NUMBER 0 0 CD hr) HOST PROOF 30'-0" LO_VE 30' 99 30' 9, LO UVE 30' 99 HOST HOSE 2L" A.F.F. 1 1 1 1 11/4 1Y4.._ x-10?- C' /aoI INSTALL . PRIGHTS ON EITHER SID OVERHEAD DOO OR BELOW DOOR A TRACK, NOT MORE THAN 12" BOD 12"x48" 3003 EY ICH': DU. WITH IVOUN EQUAL). DROVIUE _U BASE- -OF - 3 K 0 30' LLA DA RA TIN 3 B A G 99 3 WE VIOU\TE 3T ST0 \ ODTIO AUTON/AT 3 AT 36" E P3-25 H (03 C \DE3SLAB - CONDUIT TO BOLLARD 11/4 10-41/2 SALLY PORT (-3") 1 �� INSTALL UPRIGHTS ON EITHER SIDE OF NEW OVERHEAD DOORS @ OR BELOW DOOR AND TRACK, NOT MORE THAN 12" BOD CA\OPY A3OVE OC Weld stamps must inspected before pipe is hung. Do not paint piping prior to h ydro,at ,Mr tea approval. 30' FILE CO Without Comments As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila 9re Prevention Bureau for conformance with current City standards. Acceptance. is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design reststotally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: L1 -a3- a 9 By: / --s I ( i D S W1 LA FIRE DEPART Please call: 575-440Z and give this job No. a -S-O(pL/ .xact address for shut. r,,r• or r?storatton aoDrAvm. FROST PROOF -OSE 3163 @ 24" A.F.F. 3 3 03 BI@ 'Lc' M) • o/NN <,\• „ +9— 10” NI 21/2 21/2 9-0..:2=1.0 105 - 20 L_ 4 1 -8 131 L CO r=law 130 6-81/2 21/2 PED, HCIS E VA. 2 CH MEM 21/2 620-0 GG THIS DOCUMENT HAS BEEN DESIGNATED AS DEPARTMENT OF JUSTICE, IMMIGRATION AND NATURALIZATION SERVICE "LIMITED OFFICIAL USE." MATERIAL MARKED AS LIMITED OFFICIAL USE MUST BE SAFEGUARDED AGAINST UNAUTHORIZED OR INADVERTENT DISCLOSURE. IT MUST BE STORED IN A LOCKED CONTAINER WHEN NOT IN USE AND DISPOSED OF BY SHREDDING OR BURNING WHEN NO LONGER USEFUL. REPRODUCTION AND DISSEMINATION BEYOND THE RECIPIENT IS PROHIBITED WITHOUT PRIOR APPROVAL OF THE OFFICE OF SECURITY, SECURITY OPERATIONS SERVICES BRANCH, AT (202) 305-9999 OR THE ADMINISTRATIVE CENTER LAGUNA SECURITY OFFICE AT (949) 360-3178. —8 SCO3E OF WOR ADD L A G T \EW OVE SALLY 3 \D R SR RH ORT. K =LOCAT \ <L -IRS FOR D DOORS AT DEFLECTORS TO L =A BE AT OR BELOW \EW DOOPS A\D TRAC/<, \0 vORE T 12" DOW\ FHOv T E DECK REVISIONS: 21/2x 11-621 x 1, �� +9-0-10 C 1 4/17/09 ADDED DORRS @ SALLY PORT NO. DATE DESCRIPTION L -f- -1 6-6 I _ - r II -- _\ 21/2x "1'�\ \ o C � EVE1 SPR SCALP: 3/16" - try FIRE PROTECTION McKINSTRY-MAIN OFFICE 5005 3RD AVE SOUTH SEATTLE,WA. 98124 (206) 762-3311 McKINSTRY—PORTLAND OFFICE 5400 N.E. COLUMBIA BLVD PORTLAND,OR. 97218 (503) 331-0234 - R DLA\ 1' 99 - CORP 0 6x 20-0 11 �- 10-0 X 2 -H- 21/2x 3-1 Tr DEPARTMENT OF HOMELAND SECURITY SEATTLE DISTRICT OFFICE 12500 TUKWILA INTERNATIONAL BLVD. SEATTLE, WASHINGTON T 21/2x, 8-0 McKINSTRY DIVISION: FRE ROTECTIO\ DRAWN BY: JEM CHECKED BY: -3 JOB NUMBER: 300762 DATE: 4/17/19 SCALE: 3/16" = 1' - SHEET TITLE: Fire Sprinkler Plan Level 1 SHEET NUMBER: PLOT DATE: 4-20-04 PAID ?009 Tukwila Fire GENERAL LEGEND —D --4 BOD BOB BOJ FOS FOW EARTHQUAKE BRACING PIPE HANGER GROOVED CAP RIGID COUPLING ( UNLESS NOTED ) CAP PLUG. CENTERLINE HYDRAULIC REFERENCE POINT CENTERLINE PIPE TO BOTTOM OF DECK CENTERLINE PIPE TO BOTTOM OF BEAM CENTERLINE PIPE TO BOTTOM OF JOIST FACE OF STUD FACE OF WALL FOC AFF CH R.C. E/C C/C C/E GG TG TxF ATR FACE OF CONCRETE ABOVE FINISHED FLOOR CEIUNG HEIGHT REDUCING COUPLING OUTLET COUPLING WELDED OUTLET "FIT" FITTING END TO CENTER CENTER TO CENTER CENTER TO END GROOVE/GROOVE THREAD/GROOVE (ALSO "GT") THREAD/"FIT" (ALSO "FxT") ALL -THREAD ROD TYPICAL EQ BRACING NO SCALE 1090' 10" NEW DHS BUILDING L1 FIN FLR= 124.0 FLOW TEST: 160 PSI STATIC (108' EL) 138 PSI RESIDUAL (93' EL) 1550 GPM FLOWING ADJUSTED TEST TO 93' ELEVATION: 166.5 PSI STATIC 138 PSI RESIDUAL 1550 GPM FLOWING 12201 TUKWILA INTERNATIONAL BLVD DATE: 2/2/01 1540' 12". SITE PLAN FOR INFORMATION ONLY - ALL UTILITIES WORK BY OTHERS SCALE: 1" = 60' 0 30' 60' 120' REVISIONS: NO. DATE DESCRIP11ON I9»+ TUKWILA INTERNATIONAL BLVD GENERAL NOTES: (30 SPRINKLER SYSTEM DESIGN PER N.F.P.A. #13 ALL MATERIALS SHALL BE NEW AND U.L. LISTED OR F.M. APPROVED FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH N.F.P.A. #13 IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT IS THE OWNERS RESPONSIBILITY TO PROVIDE HEAT THROUGHOUT THE WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE , DELUGE AND OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE SPRINKLER SYSTEM OR ANY APPURTENANCES THEREOF ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING OR PATCHING TO BE BY OTHERS BUILDING PROVIDED WITH COMBINATION WET STANDPIPE (NORTH AND SOUTH STAIRS) WITH 2-1/2" FIRE HOSE VALVES (2 PER LEVEL) PARKING LEVELS: ORDINARY HAZARD GP I CALCULATED .15 / 1950 S.F. - DRY SYSTEMS OFFICE LEVEL L1-L4: ORDINARY HAZARD GP I CALCULATED .15/ 1500 S.F. - WET SYSTEM 2 - 21" HOSE VALVES PROVIDED AT ROOF OUTSIDE SOUTH STAIR TOWER ROOF HOSE VALVES CALCULATED FOR 500 GPM @ 100 PSI WITH 250 GPM FOR 2ND STANDPIPE, 750 GPM TOTAL 150' - 13/4" FIRE HOSE IN CABINET PROVIDED AT LEVELS 2 AND 4 NORTH AND SOUTH STAIRS QUICK RESPONSE SPRINKLERS UTILIZED THOUGHTOUT PROJECT SPRINKLER HEADS TO BE ALIGNED IN CEILING TILE 1"-2" THREADED PIPING TO BE 'DYNA-THREAD' 11/2" - 4" GROOVED PIPING TO BE 'DYNA-FLOW' / 6" GROOVED PIPING S10 DRY SYSTEM PIPING SLOPED TO DRAIN - 1/2" PER 10' FOR LINES / 1/4" PER 10' FOR MAINS CENTRAL STATION MONITORING PROVIDED BY OTHERS t% A CS 7 4t, 7 4s 'tQo CONCRETE POST -TENSION DECK c'oo�P- m k 'ANCHORTEK ULTRA PRE-SET CONCRETE INSERT' (3/8" EXCEPT 1/2" FOR EQ BRACING) ATR = 4" AND SMALLER PIPE RING HANGER TYPICAL SPRINKLER PIPING HANGER NO SCALE ACCE TED Without Comments 0 As Noted In Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards, Acci-,p-t nce is :fubJ to errors and omisS,c`n. !-i ,` f sot';: Sthor: violations of adopted The c,,:.:7,:Tonsibili y for the aden, ctr # s r tot 1;,y ...ti; the designer. Additions, c-.:v':s c r;7, ... ::.ae drawings after this date will i; O: ~i this, r cct: t> .anc€. end will require a resubmittal of revised dfavrings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwi - Fire Prevention Burea . Q t: 1 o 0 By: TUKWILA FIRE DEPARTMENT Please call: 575-4407 and give this job IVo.Cy-- /5167/ and exact address for shut. down or restoration approval; DEX instry FIRE PROTECTION McKINSTRY-MAIN OFFICE 5005 3RD AVE SOUTH SEATTLE, WA. 98124 (206) 762-3311 McKINSTRY-PORTLAND OFFICE 5400 N.E. COLUMBIA BLVD PORTLAND,OR. 97218 (503) 331-0234 004^nt hick ;1 FP -1 SITE PLAN / NOTES FP -2 PARKING LEVEL 3 FP -3 PARKING LEVEL 2 FP -4 PARKING LEVEL 1 FP -5 OFFICE LEVEL 1 FP -6 OFFICE LEVEL 2 FP -7 OFFICE LEVEL 3 FP -8 OFFICE LEVEL 4 FP -9 ROOF PLAN FP -14 FP -11 'hfOugh Deccl DEPARTMENT OF HOMELAND SECURITY SEATTLE DISTRICT OFFICE 12500 TUKWILA INTERNATIONAL BLVD. SEATTLE, WASHINGTON NORTH STAIR STANDPIPE SOUTH STAIR STANDPIPE & STANDPIPE ISOMETRIC McKINSTRY DMSION: FIRE PROTECTION DRAWN BY: GB CHECKED BY: JOB NUMBER: 689 DATE: 9-30-03 SCALE: NOTED SHEET TITLE: Fire Sprinkler Plan Site Plan SHEET NUMBER: P PLOT DATE: 10-28-03 9st-tiSlt I.1 41 , � ,:, 1 1 A FIG. G. 910 SWIVEL SWAY BRACE FITTING BRACE PIPE\ 'A` FIG. 1000 ��'., FAST CLAMP SWAY BRACE ATTACHMENT \�/ { �;/ �l / O LATERAL EARTHQUAKE BRACE FlG 910 SWIVEL SWAY BRACE FITTING 4 BRACE PIPE . • A a FIG 949 NO -THREAD SWIVEL SWAY BRACE ATTACHMENT � BRACE PIPE � FIG. 849 SWIVEL SWAY BRACE FITTING BRACE PIPE FIG 1000 FAST CLAMP"® Y RA ATTACHMENT SWAY BRACE ATT CH ENT �� Sr. © LATERAL EARTHQUAKE BRACE LEAF SPRING CONFIGURATION AND ORIENTATION BEFORE NUTS ARE TIGHTENED TOLCO FIG. 1 000 L PRLAA �P ® w/ TO ASSURE MINIMUM SHOWN FIAT REQUIRED TORQUE- N, 'll UNTIL ELEAF SPNUTS RING IS FLAT �� LATERAL EARTHQUAKE BRACE O O ' = : TOLCO FIG. l 909 {2} �.!% TOLCO FIG. TOOd "FAST CLAMP”® ,4 I4 1` 3" MAX 4 WAY EARTHQUAKE BRACE @ i- i"'1 t i TOLCO FIG. 907 TOLCO FIG. 949 (2) �..% ��, L► TSL FiCG�M1P00�'0(2) a FAST CLAMP RISER BRACE ( �'� u FIG. 4A PIPE CLAMP FOR SWAY BRACE ® LONGITUDINAL EARTHQUAKE BRACE FIG. 4A PIPE CLAMP FOR SWAY BRACE ® LONGITUDINAL EARTHQUAKE BRACE ID e0 AA LATERAL/LONGITUDINAL EARTHQUAKE BRACE 10 EO LEAF SPRING CONFIGURATION MI., GO BRACE PIPE THREADED ONE END l0 O 11-IREADED BRACE PIPE 1 L en NON THREADED BRACE'PIPE 1D L 0.0 NON THREADED BRACE PIPE TYPICAL EQ BRACING NO SCALE 1090' 10" NEW DHS BUILDING L1 FIN FLR= 124.0 FLOW TEST: 160 PSI STATIC (108' EL) 138 PSI RESIDUAL (93' EL) 1550 GPM FLOWING ADJUSTED TEST TO 93' ELEVATION: 166.5 PSI STATIC 138 PSI RESIDUAL 1550 GPM FLOWING 12201 TUKWILA INTERNATIONAL BLVD DATE: 2/2/01 1540' 12". SITE PLAN FOR INFORMATION ONLY - ALL UTILITIES WORK BY OTHERS SCALE: 1" = 60' 0 30' 60' 120' REVISIONS: NO. DATE DESCRIP11ON I9»+ TUKWILA INTERNATIONAL BLVD GENERAL NOTES: (30 SPRINKLER SYSTEM DESIGN PER N.F.P.A. #13 ALL MATERIALS SHALL BE NEW AND U.L. LISTED OR F.M. APPROVED FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH N.F.P.A. #13 IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT IS THE OWNERS RESPONSIBILITY TO PROVIDE HEAT THROUGHOUT THE WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE , DELUGE AND OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE SPRINKLER SYSTEM OR ANY APPURTENANCES THEREOF ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING OR PATCHING TO BE BY OTHERS BUILDING PROVIDED WITH COMBINATION WET STANDPIPE (NORTH AND SOUTH STAIRS) WITH 2-1/2" FIRE HOSE VALVES (2 PER LEVEL) PARKING LEVELS: ORDINARY HAZARD GP I CALCULATED .15 / 1950 S.F. - DRY SYSTEMS OFFICE LEVEL L1-L4: ORDINARY HAZARD GP I CALCULATED .15/ 1500 S.F. - WET SYSTEM 2 - 21" HOSE VALVES PROVIDED AT ROOF OUTSIDE SOUTH STAIR TOWER ROOF HOSE VALVES CALCULATED FOR 500 GPM @ 100 PSI WITH 250 GPM FOR 2ND STANDPIPE, 750 GPM TOTAL 150' - 13/4" FIRE HOSE IN CABINET PROVIDED AT LEVELS 2 AND 4 NORTH AND SOUTH STAIRS QUICK RESPONSE SPRINKLERS UTILIZED THOUGHTOUT PROJECT SPRINKLER HEADS TO BE ALIGNED IN CEILING TILE 1"-2" THREADED PIPING TO BE 'DYNA-THREAD' 11/2" - 4" GROOVED PIPING TO BE 'DYNA-FLOW' / 6" GROOVED PIPING S10 DRY SYSTEM PIPING SLOPED TO DRAIN - 1/2" PER 10' FOR LINES / 1/4" PER 10' FOR MAINS CENTRAL STATION MONITORING PROVIDED BY OTHERS t% A CS 7 4t, 7 4s 'tQo CONCRETE POST -TENSION DECK c'oo�P- m k 'ANCHORTEK ULTRA PRE-SET CONCRETE INSERT' (3/8" EXCEPT 1/2" FOR EQ BRACING) ATR = 4" AND SMALLER PIPE RING HANGER TYPICAL SPRINKLER PIPING HANGER NO SCALE ACCE TED Without Comments 0 As Noted In Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards, Acci-,p-t nce is :fubJ to errors and omisS,c`n. !-i ,` f sot';: Sthor: violations of adopted The c,,:.:7,:Tonsibili y for the aden, ctr # s r tot 1;,y ...ti; the designer. Additions, c-.:v':s c r;7, ... ::.ae drawings after this date will i; O: ~i this, r cct: t> .anc€. end will require a resubmittal of revised dfavrings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwi - Fire Prevention Burea . Q t: 1 o 0 By: TUKWILA FIRE DEPARTMENT Please call: 575-4407 and give this job IVo.Cy-- /5167/ and exact address for shut. down or restoration approval; DEX instry FIRE PROTECTION McKINSTRY-MAIN OFFICE 5005 3RD AVE SOUTH SEATTLE, WA. 98124 (206) 762-3311 McKINSTRY-PORTLAND OFFICE 5400 N.E. COLUMBIA BLVD PORTLAND,OR. 97218 (503) 331-0234 004^nt hick ;1 FP -1 SITE PLAN / NOTES FP -2 PARKING LEVEL 3 FP -3 PARKING LEVEL 2 FP -4 PARKING LEVEL 1 FP -5 OFFICE LEVEL 1 FP -6 OFFICE LEVEL 2 FP -7 OFFICE LEVEL 3 FP -8 OFFICE LEVEL 4 FP -9 ROOF PLAN FP -14 FP -11 'hfOugh Deccl DEPARTMENT OF HOMELAND SECURITY SEATTLE DISTRICT OFFICE 12500 TUKWILA INTERNATIONAL BLVD. SEATTLE, WASHINGTON NORTH STAIR STANDPIPE SOUTH STAIR STANDPIPE & STANDPIPE ISOMETRIC McKINSTRY DMSION: FIRE PROTECTION DRAWN BY: GB CHECKED BY: JOB NUMBER: 689 DATE: 9-30-03 SCALE: NOTED SHEET TITLE: Fire Sprinkler Plan Site Plan SHEET NUMBER: P PLOT DATE: 10-28-03 9st-tiSlt REMOTE AREA fP3 ORDINARY HAZARD .15 / 1950 S.F. NO WALL?? 10=d' 5'-0" 5'-0" 12'-6" $,-s" SLAB ON GRADE 2/ iii 21/2 11-101/2 22x 2-0 (,1 (1 4-101 9-101/2 �41 5-101 7-4 THIS RM TO BE FIELD COORDINATED WITH ELECTRICAL CONTRACTOR 81" SLEE SLA 4" HUB DRAIN 9-101/2 .. . 1:4if r,ei","it..:.rAA4r4r4a4-ir.ra�1e♦rar.i'iis-a-a'A"4-ir174.X4A:♦:a:ir,,re; i7i :4 4.1.1x4♦AWA i♦iaA:♦A:11AA747.71 AUX DRAIN, ti•ni AAA.a,1AaA_i1414.1♦:a'4AI,67"7♦7471'a'a7-4A11.a�.♦V1.7.74♦:s .474 111.1•114, 70.41,6 "4447* p.-0.CA:MraAr1.aA. ...... . .M..1+.�� �.♦�a�a�.♦.+• Sri" SLEEVE 4" CORE DRILL FOR 0 18'1 ABV FF 4" HUB DRAIN 9-101/2 4" CORE DRILL FOR DRAIN 0 1n ABV FF 10" DIA x 81/" SLEEVE P2 SLAB 2 10-8 A-3 6-6 2-10 7-8 3-0r 10-0 A-6 SLOPE DN 8-0 SLOPE DN 6-6 2 10-0 2 l A-11 SPRI I_. li.•-ice" rt ) q: :1 \1KLERS - THIS SHEET QTY 0 TYCO TY -FRB QUICK RESPONSE BRASS UPRIGHT 1/2" 155' 351 • ® TYCO TY -FRB QUICK RESPONSE CHROME RECESSED PENDENT 1/2" 165' W/ CHROME RECESSED CANOPY — I> TYCO TY -FRB QUICK RESPONSE BRASS HOR. SIDEWALL 1/2" 155' 4 TOTAL: 355 %n --n" • 30 Li PARKING LEVEL P3 SPRINKLER PLAN SCALE: 1/8" = 1'-O" IIIA I 0 4' 8' REVISIONS: NO. DATE DESCRIPTION 16' instry FIRE PROTECTION McKINSTRY-MAIN OFFICE 5005 3RD AVE SOUTH SEATTLE, WA. 98124 (206) 762-3311 McKINSTRY-PORTLAND OFFICE 5400 N.E. COLUMBIA BLVD PORTLAND,OR. 97218 (503) 331-0234 DEPARTMENT OF HOMELAND SECURITY SEATTLE DISTRICT OFFICE 12500 TUKWILA INTERNATIONAL BLVD. SEATTLE, WASHINGTON McKINSTRY DMSION: FIRE PROTECTION DRAWN BY: GB CHECKED BY: JOB NUMBER: 689 DATE 9-30-03 SCALE: 1/8" = 1'-0" SHEET TITLE: Fire Sprinkler Pian Parking Level P-3 SHEET NUMBER: F PLOT DATE 11-19-03 2 r -- Z (5 •fir 1 rn 1'h -- 1 0 21/2 '11/2 11/2 10-0 (— —I 2-8 6-10 10 0 ? 2-6 7-6 21 10-0 14x24 (51/2" B 1'/4 11-101/2 1-4 9-101 9-10'1 9-10'6 7-101 14x24 (51/2" B ) _a • • x 2'1 1 22 6-9 3-7 8-8 21r r- 1-0 1% 1'/4 1-10 ' -10 1 F ,R071 Ii CY-- L�• f i ;,) SPRI \KLERS - THIS SHEET QTY O TYCO TY -FRB QUICK RESPONSE BRASS UPRIGHT 1/2" 155' 321 o TYCO TY -FRB QUICK RESPONSE CHROME RECESSED PENDENT W/ CHROME RECESSED CANOPY 1/2" 165' — TOTAL: 321 0" I .l 4 _ , -0" 10,-0" PARKING LEVEL P2 SPRINKLER PLAN SCALE: 1/8" = 1'-0" 0 4' 8' REVISIONS: NO. DATE DESCRIPTION 16' Insfry FIRE PROTECTION McKINSTRY-MAIN OFFICE 5005 3RD AVE SOUTH SEATTLE, WA. 98124 (206) 762-3311 McKINSTRY-PORTLAND OFFICE 5400 N.E. COLUMBIA BLVD PORTLAND,OR. 97218 (503) 331-0234 D jf .J C 5 SEE PARKING; LEVEL P1 FOR TYPICAL H } YDRAULId CALCULATIONS 1 DEPARTMENT OF HOMELAND SECURITY SEATTLE DISTRICT OFFICE 12500 TUKWILA INTERNATIONAL BLVD. SEATTLE, WASHINGTON McKINSTRY DMSION: FIRE PROTECTION GB DRAWN BY: CHECKED BY: JOB NUMBER: 689 DATE: 9-30-03 SCALE: 1/8" = 11-0" SHEET TITLE: Fire Sprinkler Plan Parking Level P-2 SHEET NUMBER: FP -3 PLOT DATE: 11-19-03 DC 50' 50' 1 1 2) 11=11=11= 1 1 =MO= 1 1 O 4 A REMOTE AREA #P1 .15 / 1950 SF 114 7-10 114 lY4 11-10/ 1-4 9-1012 7-101 T I v 21/2i2i 21z 2 6-6 3-6 5-4 4-8 e_ 1/2 er- _ I 1 Q 1Y4 i 3-1 5-1Q g.„,„:12/21 11-1012 114 114 -41 7-101 UP & DN. SUPPLY UP IRST FLOOR VE THRU BEAM BACKFL 114 114 114 O 9-101 8-41 7-101 6"F STANDPIPE UP & DN. 4-8 12'-0" 21/2 2 21/2 -• 07-0 ;II 241 rn 10-0 X12 21 21/2 2 4-0 2-6 10-0 ,\ 7-6 11/4 11-101/2 WORK TO FLANGE UILDING 11-101/2 MACH RM CONTRL VA ELEV MACH RM 11-101/2 11-101 11-1012 11-101/2 IP o . ,1 r " � 14'-8" 13'-o" 11'-4" 9'-8" mum 8'-2" r TO WET SWIMS DRY SYSTEM AIR CAPACITY: 480 GAL/SYS SECTION 'A' — RISER RM SCALE: 1/4" = 1'-0" L-1 f,: ' V 1- >- >-=W J J V) 0 a. c -J z C1_ a.M W z o�o cn V) CI O TO STDPIPE C CO 6'-6" 5'-711 4'-11" 4'-4" 2'-6 5�A 4'- /G.4 A P d J J P-1 0 CV 3'-101, 3'-7" SECTION 'B' — WALL PENETRATIONS SCALE: 1/4" = 1'-0" I REVISIONS: NO. DATE DESCRIPTION SPRI 1 q : , \KLRS - THIS SHEET QTY 0 TYCO TY -FRB QUICK RESPONSE BRASS UPRIGHT 1/2" 155' 346 TYCO TY -FRB QUICK RESPONSE CHROME RECESSED PENDENT W/ CHROME RECESSED CANOPY 1/2" 165' — TYCO TY -FRB QUICK RESPONSE BRASS HOR. SIDEWALL 1/2" 155'. 1 instry FIRE PROTECTION McKINSTRY-MAIN OFFICE 5005 3RD AVE SOUTH SEATTLE,WA. 98124 (206) 762-3311 McKINSTRY-PORTLAND OFFICE 5400 N.E. COLUMBIA BLVD PORTLAND,OR. 97218 (503) 331-0234 TOTAL: 347 1 "lJ'. • 1 0"--1...1 1 INSULATION DEPTH? PARKING LEVEL P1 SPRINKLER PLAN SCALE: 1/8" = 1'-0" 0 4' 8' DEPARTMENT OF HOMELAND SECURITY SEATTLE DISTRICT OFFICE 12500 TUKWILA INTERNATIONAL BLVD. SEATTLE, WASHINGTON McKINSTRY DMSION: FIRE PROTECTION GB DRAWN BY: CHECKED BY: JOB NUMBER: 689 DATE 9-30-03 SCALE: 1/8" = 1'-0" SHEET TITLE: Fire Sprinkler Plan Parking Level PA SHEET NUMBER: FP -4 PLOT DATE: 11-19-03 1 i kt r --I-----4 2-(j I- 2-4- -5-8- -ii ; 21 9-8 . I- O e ryi+.a.:a'+i w4pa 'moi J ti Q SPRI <LERS - THIS SHEET QTY Q TYCO TY -FRB QUICK RESPONSE BRASS UPRIGHT 1/2" 155' 9 ® TYCO TY -FRB QUICK RESPONSE CHROME RECESSED PENDENT 1/2" 165' 320 W/ CHROME RECESSED CANOPY TOTAL: 329 REVISIONS: NO. DATE DESCRIPTION LEVEL 2 SPRINKLER PLAN SCALE: 1/8" = 1'-0" 11111 1 0 4' 8' 16' insfry FIRE PROTECTION McKINSTRY-MAIN OFFICE 5005 3RD AVE SOUTH SEATTLE, WA. 98124 (206) 762-3311 McKINSTRY-PORTLAND OFFICE 5400 N.E. COLUMBIA BLVD PORTLAND,OR. 97218 (503) 331-0234 PIPING AT 8" g ABOVE CEILING EXCEPT AS NOTED DEPARTMENT OF HOMELAND SECURITY SEATTLE DISTRICT OFFICE 12500 TUKWILA INTERNATIONAL BLVD. SEATTLE, WASHINGTON McKINSTRY DMSION: FIRE PROTECTION GB DRAWN BY: CHECKED BY: JOB NUMBER: 689 DATE 9-30-03 SCALE: 1 /8" = 1'-0" SHEET TITLE: Fire Sprinkler Plan Level 2 SHEET NUMBER: FP -6 PLOT DATE: 11-19-03 k SPRI\<LERS - THIS SHEET QTY Q TYCO TY -FRB QUICK RESPONSE BRASS UPRIGHT 1/2" 155' 8 ® TYCO TY -FRB QUICK RESPONSE CHROME RECESSED PENDENT 1/2" 165' 316 W/ CHROME RECESSED CANOPY TOTAL: 324 LEVEL 3 SPRINKLER PLAN SCALE: 1/8" = 1'-0" 0 . 4' 8' REVISIONS: NO. DATE DESCRIPTION 16' nstry FIRE PROTECTION McKINSTRY—MAIN OFFICE 5005 3RD AVE SOUTH SEATTLE, WA. 98124 (206) 762-3311 McKINSTRY—PORTLAND OFFICE 5400 N.E. COLUMBIA BLVD PORTLAND,OR. 97218 (503) 331-0234 PIPING AT 8" g ABOVE CEILING EXCEPT AS N TED DEPARTMENT OF HOMELAND SECURITY SEATTLE DISTRICT OFFICE 12500 TUKWILA INTERNATIONAL BLVD. SEATTLE, WASHINGTON MCKINSTRY DMSION: FIRE PROTECTION DRAWN BY: GB CHECKED BY: JOB NUMBER: 689 DATE: 9-30-03 SCALE: 1 /8" = 1'-O" SHEET TITLE: Fire Sprinkler Plan Level 3 SHEET NUMBER: FP -7 PLOT DATE: 11-19-03 1 • i• s 2i 2-4- :`. -5-8 ^4. :7.704.-, Vir,.*.o—.-.-.e...7.744. Air 744.4.... s n_. rn 0 REMOTE AREA #L4 ORDINARY HAZARD .15 / 1500 S.F. SPRI \KLERS - THIS SHEET QTY 0 TYCO TY -FRB QUICK RESPONSE BRASS UPRIGHT 1/2" 155' 8 ® TYCO TY -FRB QUICK RESPONSE CHROME RECESSED PENDENT 1/2" 165' 306 W/ CHROME RECESSED CANOPY TOTAL: 314 LEVEL 4 SPRINKLER PLAN SCALE: 1/8" = 1'-0" IIIII 0 4' 8' REVISIONS: NO. DATE DESCRIPTION 16' insfry FIRE PROTECTION McKINSTRY-MAIN OFFICE 5005 3RD AVE SOUTH SEATTLE, WA. 98124 (206) 762-3311 McKINSTRY-PORTLAND OFFICE 5400 N.E. COLUMBIA BLVD PORTLAND,OR. 97218 (503) 331-0234 PIPING AT 8" 0 ABOVE CEILING EXCEPT AS OTED DEPARTMENT OF HOMELAND SECURITY SEATTLE DISTRICT OFFICE 12500 TUKWILA INTERNATIONAL BLVD. SEATTLE, WASHINGTON McKINSTRY DMSION: FIRE PROTECTION DRAWN BY: GB CHECKED BY: JOB NUMBER: 689 DATE: 9-30-03 SCALE: 1/8" = 1'-0" SHEET TITLE: Fire Sprinkler Plan Level 4 SHEET NUMBER: FP -8 PLOT DATE: 11-19-03 .4 • t 6 • [:::] 1 V4" FROM BELOW ROOF VALVE CONTROL n n n n ROOF CONNECTION - SOUTH STAIR NLY 2 - 21/2" ANGLE HOSE VALVES 0 SPRIN <LERS - THIS SHEET QTY J TYCO TY -FRB QUICK RESPONSE BRASS UPRIGHT 1/2" 155' 13 o TYCO TY -FRB QUICK RESPONSE CHROME RECESSED PENDENT W/ CHROME RECESSED CANOPY 1/2" 165' _ TOTAL: 13 REVISIONS: NO. DATE DESCRIPTION ROOF LEVEL SPRINKLER PLAN SCALE: 1/8" = 1'-0" 1 1 1 1 I 1 0 4' 8' 16' instry FIRE PROTECTION McKINSTRY-MAIN OFFICE 5005 3RD AVE SOUTH SEATTLE, WA. 98124 (206) 762-3311 McKINSTRY-PORTLAND OFFICE 5400 N.E. COLUMBIA BLVD PORTLAND,OR. 97218 (503) 331-0234 DEPARTMENT OF HOMELAND SECURITY SEATTLE DISTRICT OFFICE 12500 TUKWILA INTERNATIONAL BLVD. SEATTLE, WASHINGTON McKINSTRY DMSION: FIRE PROTECTION DRAWN BY: GB CHECKED BY: JOB NUMBER: 689 DATE: 9-30-03 SCALE: 1/8" = 1'-0" SHEET TITLE: Fire Sprinkler Plan Roof level SHEET NUMBER: FP -9 PLOT DATE: 11-19-03 ROOF CONNECTION 2 - 21/2" HOSE VALVES (VALVE CONTROL BEHOND) SEE FP -RF ROOF PLAN STAIR PENTHOUSE L4 — 165' �I. L3 - 152 _. RISER CLAMP - 0 . L2 — 139' 04 6" SUPPLY L1 — 24' „ COCPPI cN N X 2" EXP cV n (V 2111:1111:11::: N J1° VARIES (FIELD VERIFY) . 0 0 0 0 0 0 ROOF LEVEL 4 LEVEL 3 LEVEL 2 LEVEL 1 --e LOCATE FIRE HOSE CABINETS 0. W/ 75' 11/2" HOSE N AT FLOORS 2 AND 4 EACH STAIR LEVEL P-2 _-s 0 DII PIPE TO DRAIN trio 0 SOUTH STAIR STAIR #3 -LOOKING NORTH 8' 4' 2' 0 1/4" = 1'-0 SCALE: 0 LEVEL P-3 -e REVISIONS: NO. DATE DESCRIPTION 0 ROOF CONNECTION (SOUTH STAIR ONLY) 2 - 21/2" HOSE VALVES N.R.S. VALVE W OUTSIDE CONTROL 0EL=183' O N) 100 PSI / 500 GPM REQUIRED AT REF PT 200 0 —70 4, kel 0 N) 3 cONl1pO 114 3 3h (-0NTi)0 ! 1/q Lq SOUTH STANDPIPE " / VT {04/7' 1 > of I/4 �3 l� c 04 1/q 0 SSS 0�� S( SSS 18 Q� Q20�� P� 0S( NORTH STANDPIPE 3 Lq AA A (>)9004/6 TO PARKING (TYP. TO S. STDPIPE) insfry FIRE PROTECTION McKINSTRY-MAIN OFFICE 5005 3RD AVE SOUTH SEATTLE, WA. 98124 (206) 762-3311 McKINSTRY-PORTLAND OFFICE 5400 N.E. COLUMBIA BLVD PORTLAND,OR. 97218 (503) 331-0234 SUPPLY IN HEATED CHASE PARKING LEVEL P1 (2 - 8" SUPPLIES) MCKINSTRY TO START AT FLG INSIDE BDLG 've/oj STA\D DID ISO NO SCALE V =TRIC DEPARTMENT OF HOMELAND SECURITY SEATTLE DISTRICT OFFICE 12500 TUKWILA INTERNATIONAL BLVD. SEATTLE, WASHINGTON McKINSTRY DMSION: FIRE PROTECTION DRAWN BY: GB CHECKED BY: JOB NUMBER: 689 DATE: 9-30-03 SCALE: 1/8" = SHEET TITLE: Fire Sprinkler Plan South Stair Standpipe SHEET NUMBER: FP -SSP PLOT DATE: 10-28-03 STAIR PENTHOUSE ROOF a.: LEVEL 4 • j :I LEVEL 3 LEVEL 2 LEVEL LEVEL P-1 6" SUPPLY 0 6'-8' LEV 1 LEVEL P-2 LEVEL P-3 399 GRVxGRV BUTTERFLY VALVE W/ TAMPER SWITCH 379 GRVxGRV SWING CHECK VALVE WATERFLOW SWITCH 11/4" TEST—N—DRAIN 2" DRAIN STANDPIPE LOCATE FIRE HOSE CABINETS W/ 75' 11/2" HOSE AT FLOORS 2 AND 4 EACH STAIR I PIPE TO DRAIN NORTH STAIR STAIR #2 - LOOKING SOUTH SCALE: 1/4" = 1'-0" 0 2' 4' 8' REVISIONS: NO. DATE DESCRIPTION CN 1 CO ors 00 CO X CO CO N) X CO 5" SUPPLY © C_8' ©LEV1 21/2" HOSE VALVE f TYPICAL FLOOR VALVE DETAIL SCALE: 3/4" = 1'-0" instry FIRE PROTECTION McKINSTRY-MAIN OFFICE 5005 3RD AVE SOUTH SEATTLE,WA. 98124 (206) 762-3311 McKINSTRY-PORTLAND OFFICE 5400 N.E. COLUMBIA BLVD PORTLAND,OR. 97218 (503) 331-0234 DEPARTMENT OF HOMELAND SECURITY SEATTLE DISTRICT OFFICE 12500 TUKWILA INTERNATIONAL BLVD. SEATTLE, WASHINGTON McKINSTRY DMSION: FIRE PROTECTION DRAWN BY: GB CHECKED BY: JOB NUMBER: 689 DATE: 9-30-03 SCALE 1/8" = 1'-0" SHEET TITLE: Fire Sprinkler Plan North Stair Standpipe SHEET NUMBER: FP -NSP PLOT DATE: 10-28-03 12500 TUKWILA INTERNATIONAL BLVD ASSOCIATED PERMITS 04-5-195 Page 1 of 14 HYDRAULIC CALCULATIONS MCKINSTRY COMPANY Date 09/22/04 Job: DHS-L4T Job_ _ DEPT OF HOMELAND SECURITY - LEVEL 4 tenant level TUKWILA, WASHINGTON Occupancy Density Area of Application Coverage per Sprinkler ORDINARY HAZARD 0.15 gpm/sq.ft. 1500 square feet 130 S.F. MAX System type_ _ Wet Hose 250.0 gpm Inside Hose Water Supply _ 166.50 psi Static, 138.00 psi Residual @ 1550.0 gpm Sprinklers - - K=5.6 Demand_ _ _ _ 127.00 psi @ 680.7 gpm @ B.O.R. 127.00 psi @ 680.7 gpm @ Supply 160.28 psi available @ 680.7 gpm Demand is below curve by 33.28 psi Page 2 MCKINSTRY COMPANY Description of Fitting abbreviations Code Description T Tee E Ninety degree elbow VT Victaulic tee VE Victaulic ninety degree elbow B11 Backflow: Ames 2000ss/3000ss Silver Bullet BV Butterfly valve CV Swing check valve UE Underground ASCA ninety degree elbow UEE Underground ASCA forty five degree elbow UT1 Underground ASCA tee: flow in run, flow out bullhead only Description of Other abbreviations Code Description DR Drop BL Branch Line CM .Cross Main PT Total pressure PE Pressure loss due to elevation changes PF Pressure loss due to friction .5 Raised to the power of .5 (Square Root) A Actual pipe length F Fitting equivalent pipe length T Total pipe length Page 3 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 4 tenant level TUKWILA, WASHINGTON Raw data previous to any calculations No. Code Diam Length Beg End Nd Kfacl Kfac2 Press Elev Hose HW Vel Fit 1 DR1 1.049 1.0 0 0 5.6 2 DR2 1.049 1.0 0 0 5.6 3 BL1 1.416 10.0 0 0 DR1 4 BL1 1.416 6.0 0 0 DR1 5 BL1 1.416 6.0 0 0 DR1 6 BL1 1.416 8.0 0 0 DR1 7 BL1 1.650 10.0 0 0 DR1 8 BL1 1.650 18.0 0 0 DR1 9 BL2 1.416 7.0 0 0 DR1 10 BL2 1.416 8.0 0 0 DR1 11 BL2 1.416 12.0 0 0 DR1 12 BL2 1.416 12.0 0 0 DR1 13 BL2 1.650 17.0 0 0 DR1 14 BL3 1.416 6.0 0 0 DR1 15 BL3 1.416 12.0 0 0 DR1 16 BL3 1.416 8.0 0 0 17 BL3 1.416 12.0 0 0 DR1 18 BL3 1.650 28.0 0 0 DR1 19 BL4 1.416 6.0 0 0 DR1 20 BL4 1.416 6.0 0 0 DR1 21 BL4 1.416 12.0 0 0 DR2 22 BL4 1.416 8.0 0 0 DR1 23 BL4 1.650 10.0 0 0 DR1 24 BL4 1.650 26.0 0 0 DR1 25 CM1 2.731 6.0 0 0 BL1 26 CM1 2.731 5.0 0 0 BL2 27 CM1 2.731 9.0 0 0 BL3 28 CM1 2.731 15.0 0 0 BL4 29 CM2L 2.731 210.0 0 0 30 CM2L 2.731 232.0 0 0 CM1 31 CM3 3.356 22.0 0 0 CM2L 201 CM4 6.357 13.0 0 0 CM3 202 CM4 6.357 13.0 0 0 203 CM4 6.357 15.0 0 0 204 CM4 6.357 202.0 0 0 7.00 -1.00 0.0 120 32 1T 10.33 -1.00 0.0 120 32 1E 0.00 0.00 0.0 120 32 0.00 0.00 0.0 120 32 0.00 0.00 0.0 120 32 0.00 0.00 0.0 120 32 0.00 0.00 0.0 120 32 0.00 0.00 0.0 120 32 1T 0.00 0.00 0.0 120 32 0.00 0.00 0.0 120 32 0.00 0.00 0.0 120 32 0.00 0.00 0.0 120 32 0.00 0.00 0.0 120 32 1T 0.00 0.00 0.0 120 32 0.00 0.00 0.0 120 32 0.00 0.00 0.0 120 32 0.00 0.00 0.0 120 32 0.00 0.00 0.0 120 32 1T 0.00 0.00 0.0 120 32 0.00 0.00 0.0 120 32 0.00 0.00 0.0 120 32 0.00 0.00 0.0 120 32 0.00 0.00 0.0 120 32 0.00 0.00 0.0 120 32 iT 0.00 0.00 0.0 120 32 0.00 0.00 0.0 120 32 0.00 0.00 0.0 120 32 0.00 0.00 0.0 120 32 1T 0.00 0.00 0.0 120 32 1VT,2VE 0.00 0.00 0.0 120 32 1VT,2VE 0.00 5.50 0.0 120 32 2VE,1VT,1CV,1BV 0.00 13.00 100.0 120 32 0.00 13.00 0.0 120 32 0.00 15.00 0.0 120 32 0.00 0.00 0.0 120 32 2T,2VE,1BV Page 4 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 4 tenant level TUKWILA, WASHINGTON Raw data previous to any calculations No. Code Diam Length Beg End Nd Kfacl Kfac2 Press Elev Hose HW Vel Fit 205 CM4 8.249 54.0 0 0 206 CM4 8.249 10.0 0 0 207 CM4 8.249 110.0 0 0 208 CM4 8.270 60.0 0 0 295 G 10.280 60.0 298 296 296 G 12.340 1090.0 296 297 1 CM4 297 G 10.280 365.0 297 298 N 298 G 10.280 1160.0 298 299 N 299 G 12.340 300.0 299 300 N 300 G 12.340 1540.0 300 301 N 301 G 12.340 130.0 301 297 N 302 BU 12.340 0.0 300 0 0.00 15.50 0.0 120 32 0.00 0.00 0.0 120 32 2VE,1B11 0.00 0.00 0.0 120 32 4VE,2T,1BV 0.00 0.00 150.0 140 32 lUT1 0.00 0.00 0.0 140 32 lUT1 0.00 0.00 0.0 140 32 2UT1,7UEE 0.00 0.00 0.0 140 32 lUT1 0.00 0.00 0.0 140 32 lUE,2UEE 0.00 0.00 0.0 140 32 lUT1,1UE 0.00 0.00 0.0 140 32 4UT1 0.00 0.00 0.0 140 32 lUT1,1UE 0.00 22.50 0.0 140 32 Page 5 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 4 tenant level TUKWILA, WASHINGTON Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Drop 1 C = 120 A 1.0 PT 7.00 1 14.8=5.60(7.00)A.5 F 5.0 PE -0.43 (EL= -1.00 ft) 1 14.8 1.05 1T T 6.0 0.07470 PF 0.45 5.50 PT 7.02 3 B1 Jct K -factor for drop 1 = 14.8/(7.02)A.5 = 5.59 at Hyd Ref Pts 3 4 5 6 7 8 9 10 11 12 13 14 15 17 18 19 20 22 23 24 Drop 2 A 1.0 PT 10.33 2 18.0=5.60(10.33)A.5 F 2.0 PE -0.43 2 18.0 1.05 1E T 3.0 0.10707 PF 0.32 6.68 PT 10.22 21 K -factor for drop 2 = 18.0/(10.22)A.5 = 5.63 C = 120 (EL= -1.00 ft) B1 Jct Page 6 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 4 tenant level TUKWILA, WASHINGTON Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Branchline No. 1 C = 120 A 10.0 PT 7.02 3 DR1 14.8=5.59(7.02)A.5 F 0.0 PE 0.00 3 14.8 1.42 T 10.0 0.01730 PF 0.17 3.02 A 6.0 PT 7.19 4 DR1 15.0=5.59(7.19)A.5 F 0.0 PE 0.00 4 29.8 1.42 T 6.0 0.06306 PF 0.38 6.07 A 6.0 PT 7.57 5 DR1 15.4=5.59(7.57)A.5 F 0.0 PE 0.00 5 45.2 1.42 T 6.0 0.13618 PF 0.82 9.20 A 8.0 PT 8.38 6 DR1 16.2=5.59(8.38)A.5 F 0.0 PE 0.00 6 61.3 1.42 T 8.0 0.23998 PF 1.92 12.50 A 10.0 PT 10.30 7 DR1 17.9=5.59(10.30)A.5 F 0.0 PE 0.00 7 79.3 1.65 T 10.0 0.18316 PF 1.83 11.89 A 18.0 PT 12.13 8 DR1 19.5=5.59(12.13)A.5 F 9.0 PE 0.00 8 98.7 1.65 iT T 27.0 0.27495 PF 7.43 14.81 PT 19.56 25 Cross main Jct K -factor for branchline no. 1 = 98.7/(19.56)A.5 = 22.31 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 4 tenant level TUKWILA, WASHINGTON Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Page 7 Notes Branchline No. 2 C = 120 A 7.0 PT 7.02 9 DR1 14.8=5.59(7.02)A.5 F 0.0 PE 0.00 9 14.8 1.42 T 7.0 0.01730 PF 0.12 3.02 A 8.0 PT 7.14 10 DR1 14.9=5.59(7.14)A.5 F 0.0 PE 0.00 10 29.7 1.42 T 8.0 0.06285 PF 0.50 6.06 A 12.0 PT 7.64 11 DR1 15.5=5.59(7.64)A.5 F 0.0 PE 0.00 11 45.2 1.42 T 12.0 0.13629 PF 1.64 9.20 A 12.0 PT 9.27 12 DR1 17.0=5.59(9.27)A.5 F 0.0 PE 0.00 12 62.2 1.42 T 12.0 0.24622 PF 2.95 12.67 A 17.0 PT 12.23 13 DR1 19.6=5.59(12.23)A.5 F 9.0 PE 0.00 13 81.7 1.65 iT T 26.0 0.19382 PF 5.04 12.26 PT 17.27 26 Cross main Jct K -factor for branchline no. 2 = 81.7/(17.27)".5 = 19.66 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 4 tenant level TUKWILA, WASHINGTON Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Page 8 Notes Branchline No. 3 C = 120 A 6.0 PT 7.02 14 DR1 14.8=5.59(7.02)A.5 F 0.0 PE 0.00 14 14.8 1.42 T 6.0 0.01730 PF 0.10 3.02 A 12.0 PT 7.12 15 DR1 14.9=5.59(7.12)A.5 F 0.0 PE 0.00 15 29.7 1.42 T 12.0 0.06278 PF 0.75 6.05 A 8.0 PT 7.87 16 F 0.0 PE 0.00 16 29.7 1.42 T 8.0 0.06278 PF 0.50 6.05 A 12.0 PT 8.37 17 DR1 16.2=5.59(8.37)A.5 F 0.0 PE 0.00 17 45.9 1.42 T 12.0 0.14027 PF 1.68 9.35 A 28.0 PT 10.06 18 DR1 17.7=5.59(10.06)A.5 F 9.0 PE 0.00 18 63.6 1.65 1T T 37.0 0.12187 PF 4.51 9.54 PT 14.57 27 Cross main Jct K -factor for branchline no. 3 = 63.6/(14.57)x.5 = 16.66 Page 9 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 4 tenant level TUKWILA, WASHINGTON Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Branchline No. 4 (Beginning pressure increased due to Hyd Ref Pt 21) C = 120 A 6.0 PT 9.58 19 DR1 17.3=5.59(9.58)A.5 F 0.0 PE 0.00 19 17.3 1.42 T 6.0 0.02308 PF 0.14 3.52 A 6.0 PT 9.72 20 DR1 17.4=5.59(9.72)A.5 F 0.0 PE 0.00 20 34.7 1.42 T 6.0 0.08375 PF 0.50 7.07 A 12.0 PT 10.22 21 DR2 18.0=5.63(10.22)A.5 F 0.0 PE 0.00 21 52.7 1.42 T 12.0 0.18141 PF 2.18 10.74 A 8.0 PT 12.40 22 DR1 19.7=5.59(12.40)A.5 F 0.0 PE 0.00 22 72.4 1.42 T 8.0 0.32620 PF 2.61 14.75 A 10.0 PT 15.01 23 DR1 21.7=5.59(15.01)A.5 F 0.0 PE 0.00 23 94.1 1.65 T 10.0 0.25130 PF 2.51 14.11 A 26.0 PT 17.52 24 DR1 23.4=5.59(17.52)A 5 F 9.0 PE 0.00 24 117.4 1.65 iT T 35.0 0.37901 PF 13.27 17.62 PT 30.80 28 Cross main Jct K -factor for branchline no. 4 = 117.4/(30.80)A.5 = 21.16 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 4 tenant level TUKWILA, WASHINGTON Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Page 10 Notes Cross main 1 (Beginning pressure increased due to Hyd Ref Pt 28) C = 120 A 6.0 PT 28.27 25 BL1 118.6=22.31(28.27)".5 F 0.0 PE 0.00 25 118.6 2.73 T 6.0 0.03319 PF 0.20 6.50 A 5.0 PT 28.46 26 BL2 104.9=19.66(28.46)A.5 F 0.0 PE 0.00 26 223.5 2.73 T 5.0 0.10715 PF 0.54 12.24 A 9.0 PT 29.00 27 BL3 89.7=16.66(29.00)A.5 F 0.0 PE 0.00 27 313.3 2.73 T 9.0 0.20006 PF 1.80 17.16 A 15.0 PT 30.80 28 BL4 117.4=21.16(30.80)A.5 F 19.6 PE 0.00 28 430.7 2.73 1T T 34.6 0.36050 PF 12.48 23.59 PT 43.28 30 Cross main Jct K -factor for Cross main 1 = 430.7/(43.28)A.5 = 65.47 Clockwise (K -Factor @ split=65.47 from CM1) C = 120 A 232.0 PT 43.28 30 Split Point F 32.7 PE 0.00 30 210.3 2.73 1VT 2VE T 264.7 0.09572 PF 25.34 11.52 PT 68.61 31 Loop Jct Counter -Clockwise (K -Factor @ split=65.47 from CM1) C = 120 A 210.0 PT 43.28 30 Split Point F 32.7 PE 0.00 29 220.4 2.73 1VT 2VE T 242.7 0.10440 PF 25.34 12.07 PT 68.61 31 Loop Jct (Balance Accuracy = 68.61 - 68.61 = 0.00) Cross main 3 C = 120 A 22.0 PT 68.61 31 Loop Jct 430.7=52.00(68.61)A.5 F 75.9 PE 2.38 (EL= 5.50 ft) 31 430.7 3.36 2VE 1VT T 97.9 0.13217 PF 12.93 15.62 1CV 1BV PT 83.93 201 Cross main Jct K -factor for Cross main 3 = 430.7/(83.93)".5 = 47.01 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 4 tenant level TUKWILA, WASHINGTON Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Page 11 Notes Cross main 4 C = 120 A 13.0 PT 83.93 201 CM 3 430.7=47.01(83.93)A.5 F 0.0 PE 5.63 (EL= 13.00 ft) 201 530.7 6.36 T 13.0 0.00867 PF 0.11 5.36 A 13.0 PT 89.67 202 F 0.0 PE 5.63 (EL= 13.00 ft) 202 530.7 6.36 T 13.0 0.00867 PF 0.11 5.36 A 15.0 PT 95.41 203 F 0.0 PE 6.50 (EL= 15.00 ft) 203 530.7 6.36 T 15.0 0.00867 PF 0.13 5.36 A 202.0 PT 102.04 204 F 113.2 PE 0.00 204 530.7 6.36 2T 2VE T 315.2 0.00867 PF 2.73 5.36 1BV A 54.0 PT 104.77 205 F 0.0 PE 6.71 (EL= 15.50 ft) 205 530.7 8.25 T 54.0 0.00244 PF 0.13 3.19 A 10.0 PT 111.61 206 F 28.9 PE 0.00 206 530.7 8.25 2VE 1B11 T 38.9 0.00244 PF 4.44 3.19 1B11 = 4.35# A 110.0 PT 116.05 207 F 149.0 PE 0.00 207 530.7 8.25 4VE 2T T 259.0 0.00244 PF 0.63 3.19 1BV A 60.0 PT 116.68 208 ** C = 140 ** 150.0 gpm = Hose F 24.0 PE 0.00 208 680.7 8.27 lUTl T 84.0 0.00287 PF 0.24 4.07 PT 116.92 296 Bulk Jct K -factor for Cross main 4 = 680.7/(116.92)A.5 = 62.95 Page 12 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 4 tenant level TUKWILA, WASHINGTON Grid Node Detail Discharge Pressure Outlet Elevation Node (gpm) (psi) K -Value Source (ft) Comments 296 680.7 116.92 K=62.95 CM 4 0.00 Split 297 - 116.99 0„00 298 - 116.97 0.00 299 - 117.22 0..00 300 (680.7) 117.26 Feed Jct 0.00 301 - 117.02 0.00 Page 13 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 4 tenant level TUKWILA, WASHINGTON Grid Pipe Detail Actual Total Elev Fric Fric Press Press Pipe Diam Len Len Head Flow Loss Loss Vel Nodes @ Beg Q End No. (inch) (Ft) (Ft) (Ft) (Gpm)(Psi/Ft)(Psi)(Fps) Beg End (Psi) (Psi) 295 10.28 60.0 90.0 0.00 -451.6 0.0005 0.04 1.7 298 296 116.97 116.92 Fit= 30.0 lUT1 296 12.34 1090.0 1227.0 0.00 229.1 0.0001 0.07 0.6 296 297 116.92 116.99 Fit= 137.0 2UT1 7UEE 297 10.28 365.0 395.0 0.00 -153.5 0.0001 0.02 0.6 297 298 116.99 116.97 Fit= 30.0 lUT1 298 10.28 1160.0 1191.0 0.00 298.2 0.0002 0.26 1.2 298 299 116.97 117.22 Fit= 31.0 lUE 2UEE 299 12.34 300.0 358.0 0.00 298.2 0.0001 0.03 0.8 299 300 117.22 117.26 Fit= 58.0 lUT1 lUE 300 12.34 1540.0 1688.0 0.00 -382.5 0.0001 0.24 1.0 300 301 117.26 117.02 Fit= 148.0 4UT1 301 12.34 130.0 188.0 0.00 -382.5 0.0001 0.03 1.0 301 297 117.02 116.99 Fit= 58.0 lUT1 lUE Page 14 MCKINSTRY COMPANY Sprinkler Systems Hydraulic Flow Calculations DEPT OF HOMELAND SECURITY - LEVEL 4 tenant level TUKWILA, WASHINGTON Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Bulk C = 140 ___= A 0.0 PT 117.26 300 Grid Jct 680.7=62.86(117.26)A.5 F 0.0 PE 9.74 (EL= 22.50 ft) 302 680.7 12.34 T 0.0 0.00000 PF 0.00 1.83 PT 127.00 303 Available flow at 127.00 psi is 1849.1 gpm which is 1168.4 gpm from curve. Supply pressure available with 680.7 gpm flowing is 160.28 psi, thus system requirement is 33.28 psi below supply curve. (20.8%) GENERAL LEGEND t —0 O BOD BOB BOJ FOS FOW EARTHQUAKE BRACING PIPE HANGER GROOVED CAP RIGID COUPUNG ( UNLESS NOTED ) CAP PLUG CENTERUNE HYDRAUUC REFERENCE POINT CENTERLINE PIPE TO BOTTOM OF DECK CENTERLINE PIPE TO BOTTOM OF BEAM CENTERUNE PIPE TO BOTTOM OF JOIST FACE OF STUD FACE OF WALL FOC AFF CH R.C. 4 F E/C C/C C/E GG TG TxF ATR FACE OF CONCRETE ABOVE FINISHED FLOOR CEILING HEIGHT REDUCING COUPLING OUTLET COUPLING WELDED OUTLET "FIT" FITTING END TO CENTER CENTER TO CENTER CENTER TO END GROOVE/GROOVE THREAD/GROOVE (ALSO "GT") THREAD/"FIT" (ALSO "FxT") ALL -THREAD ROD O N TYPICAL EQ BRACING NO SCALE 6" F.D.C. FLOW TEST: 160 PSI STATIC (108' EL) 138 PSI RESIDUAL (93' EL) 1550 GPM FLOWING ADJUSTED TEST TO 93' ELEVATION: 166.5 PSI STATIC 138 PSI RESIDUAL 1550 GPM FLOWING 12201 TUKWILA INTERNATIONAL BLVD DATE: 2/2/01 THIS DOCUMENT HAS BEEN DESIGNATED AS DEPARTMENT OF JUSTICE, IMMIGRATION AND NATURALIZATION SERVICE "LIMITED OFFICIAL USE." MATERIAL MARKED AS LIMITED OFFICIAL USE MUST BE SAFEGUARDED AGAINST UNAUTHORIZED OR INADVERTENT DISCLOSURE. IT MUST BE STORED IN A LOCKED CONTAINER WHEN NOT IN USE AND DISPOSED OF BY SHREDDING OR BURNING WHEN NO LONGER USEFUL. REPRODUCTION AND DISSEMINATION BEYOND THE RECIPIENT IS PROHIBITED WITHOUT PRIOR APPROVAL OF THE OFFICE OF SECURITY, SECURITY OPERATIONS SERVICES BRANCH, AT (202) 305-9999 OR THE ADMINISTRATIVE CENTER LAGUNA SECURITY OFFICE AT (949) 360-3178. 1090' 10" FIRE HYDRANT NEW DHS BUILDING 11111.1111111111111111111.111.1 - 8" SUPPLIES 4 FIRE HYDRANT L1 FIN FLR= 124.0 365' 12" TUKWILA INTERNATIONAL BLVD N O M 1540' 12" SITE PLAN FOR INFORMATION ONLY - ALL UTILITIES WORK BY OTHERS SCALE: 1" = 60' 0 30' 60' 120' REVISIONS: NO. DATE DESCRIPTION e77 GENERAL NOTES: SPRINKLER SYSTEM DESIGN PER N.F.P.A. #13 ALL MATERIALS SHALL BE NEW AND U.L. LISTED OR F.M. APPROVED FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH N.F.P.A. #13 IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT IS THE OWNERS RESPONSIBILITY TO PROVIDE HEAT THROUGHOUT THE WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE , DELUGE AND OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE SPRINKLER SYSTEM OR ANY APPURTENANCES THEREOF ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING OR PATCHING TO BE BY OTHERS BUILDING PROVIDED WITH COMBINATION WET STANDPIPE (NORTH AND SOUTH STAIRS) WITH 2-1/2" FIRE HOSE VALVES PARKING LEVELS: ORDINARY HAZARD GP I CALCULATED .15 / 1950 S.F. — DRY SYSTEMS OFFICE LEVEL L1—L4: ORDINARY HAZARD GP I CALCULATED .15/ 1500 S.F. — WET SYSTEM 2 2/2 HOSE VALVES PROVIDED AT ROOF OUTSIDE SOUTH STAIR TOWER ROOF HOSE VALVES CALCULATED FOR 500 GPM © 100 PSI WITH 250 GPM FOR 2ND STANDPIPE, 750 GPM TOTAL 150'I — 13/4" FIRE HOSE IN CABINET PROVIDED AT LEVELS 2 AND 4 NORTH AND SOUTH STAIRS QUICK RESPONSE SPRINKLERS UTILIZED THOUGHTOUT PROJECT SPRINKLER HEADS TO BE ALIGNED IN CEILING TILE 1"-2" THREADED PIPING TO BE 'DYNA—THREAD' 11/2" — 4" GROOVED PIPING TO BE 'DYNA—FLOW' / 6" GROOVED PIPING S10 DRY SYSTEM PIPING SLOPED TO DRAIN — 1/2" PER 10' FOR LINES / 1/4" PER 10' FOR MAINS CENTRAL STATION MONITORING PROVIDED BY OTHERS instry FIRE PROTECTION McKINSTRY-MAIN OFFICE 5005 3RD AVE SOUTH SEATTLE, WA. 98124 (206) 762-3311 McKINSTRY-PORTLAND OFFICE 5400 N.E. COLUMBIA BLVD PORTLAND,OR. 97218 (503) 331-0234 t% o Q o 7 Q 4" pC).o o C',.,DQP- a A' rk Q A PP CONCRETE POST -TENSION DECK Pr Gs D 0 d elO ACCEPTED Without Comments ❑ As Noted In Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this.acceptance and will require a resubmittal of revised drawings for subsequent approval. IIha f -Act l}`\g-i) subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: (1/9-0/0 Y By: O% rUKWILA FIRE DEPARTNvItIVt Please call: 575-4407 and give this job and exact address for shut• dvn or restoration approval_ O m N.C41 p a o. 'ANCHORTEK ULTRA PRE-SET CONCRETE INSERT' (3/8" EXCEPT 1/2" FOR EQ BRACING) W AIR = 4" AND SMALLER PIPE RING HANGER TYPICAL SPRINKLER PIPING HANGER NO SCALE DEPARTMENT OF HOMELAND SECURITY SEATTLE DISTRICT OFFICE F I L E 12500 TU ILA INTERNATIONAL BLVD. SEATTLE, WASHINGTON TENANT PLANS INDEX FP -1 4 4 SITE PLAN / NOTES FP -2 PARKING LEVEL 3 FP -3 PARKING LEVEL 2 FP -4 PARKING LEVEL 1 It FP -5 I 1 A I OFFICE LEVEL 2 k FP -7 I 1 FP -8 FIG. 909 0.• SWIVEL SWAY BRACE FITTING I BRACE / i/.!/® FAST ♦ \ i SWAY BRACE / i S/ I 0 LATERAL EARTHQUAKE BRACE PIPE CLAMP" ® ATTACHMENT FIG. 910 SWIVEL SWAY BRACE FITTING / FIG. IJP ` 'FAST BRACE PIPE 1000 CLAMP" ® FIG. 909 NO -THREAD SWIVEL SWAY BRACE ATTACHMENT lb,•. BRACE 4 ; PIPE FIG. 910 SWIVEL SWAY BRACE FITTING " BRACE `J PIPE LEAF SPRING CONFIGURATION AND ORIENTATION BEFORE NUTS ARE TIGHTENED TOLCO FIG. 1000 FAST CLAMP"et w/ _ LEAF SPRING TO ASSURE MINIMUM SHOWN FLAT ' REQUIRED TORQUE- I TIGHTEN HEX NUTS UNTIL LEAF SPRING IS FLAT JI ) ® LATERAL EARTHQUAKE BRACE . O :i a ' . '• ;= TOLCO FIG. 909 (2) L TOLCO FIG. 1000 'FAST CLAMP"® , / . N► 3 MAX 4 WAY EARTHQUAKE BRACE ,., n TOLCO FIG. 907 TOLCO FIG. 909 (2) TOLCO FIG. ► 1000 "FAST CLAMP"® (2) ID FAST CLAMP RISER BRACE ♦ SWAY BRACE ATTACHMENT t / ® LATERAL EARTHQUAKE BRACE I FlG 4A PIPE CLAMP FOR SWAY BRACE 11, LONGITUDINAL EARTHQUAKE BRACE FlG 4A / PIPE CLAMP FOR SWAY BRACE 013 LONGITUDINAL EARTHQUAKE n u BRACE 1LATERAL/LONGITUDINAL EARTHQUAKE BRACE oi1.170 Ta L Q NON -THREADED BRACE PIPE T D-TGQ NON -THREADED BRACE PIPE 1 a BRACE PIPE THREADED ONE END JO & O THREADED BRACE PIPE L 0. Q LEAF SPRING CONFIGURATION TYPICAL EQ BRACING NO SCALE 6" F.D.C. FLOW TEST: 160 PSI STATIC (108' EL) 138 PSI RESIDUAL (93' EL) 1550 GPM FLOWING ADJUSTED TEST TO 93' ELEVATION: 166.5 PSI STATIC 138 PSI RESIDUAL 1550 GPM FLOWING 12201 TUKWILA INTERNATIONAL BLVD DATE: 2/2/01 THIS DOCUMENT HAS BEEN DESIGNATED AS DEPARTMENT OF JUSTICE, IMMIGRATION AND NATURALIZATION SERVICE "LIMITED OFFICIAL USE." MATERIAL MARKED AS LIMITED OFFICIAL USE MUST BE SAFEGUARDED AGAINST UNAUTHORIZED OR INADVERTENT DISCLOSURE. IT MUST BE STORED IN A LOCKED CONTAINER WHEN NOT IN USE AND DISPOSED OF BY SHREDDING OR BURNING WHEN NO LONGER USEFUL. REPRODUCTION AND DISSEMINATION BEYOND THE RECIPIENT IS PROHIBITED WITHOUT PRIOR APPROVAL OF THE OFFICE OF SECURITY, SECURITY OPERATIONS SERVICES BRANCH, AT (202) 305-9999 OR THE ADMINISTRATIVE CENTER LAGUNA SECURITY OFFICE AT (949) 360-3178. 1090' 10" FIRE HYDRANT NEW DHS BUILDING 11111.1111111111111111111.111.1 - 8" SUPPLIES 4 FIRE HYDRANT L1 FIN FLR= 124.0 365' 12" TUKWILA INTERNATIONAL BLVD N O M 1540' 12" SITE PLAN FOR INFORMATION ONLY - ALL UTILITIES WORK BY OTHERS SCALE: 1" = 60' 0 30' 60' 120' REVISIONS: NO. DATE DESCRIPTION e77 GENERAL NOTES: SPRINKLER SYSTEM DESIGN PER N.F.P.A. #13 ALL MATERIALS SHALL BE NEW AND U.L. LISTED OR F.M. APPROVED FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH N.F.P.A. #13 IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT IS THE OWNERS RESPONSIBILITY TO PROVIDE HEAT THROUGHOUT THE WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE , DELUGE AND OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE SPRINKLER SYSTEM OR ANY APPURTENANCES THEREOF ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING OR PATCHING TO BE BY OTHERS BUILDING PROVIDED WITH COMBINATION WET STANDPIPE (NORTH AND SOUTH STAIRS) WITH 2-1/2" FIRE HOSE VALVES PARKING LEVELS: ORDINARY HAZARD GP I CALCULATED .15 / 1950 S.F. — DRY SYSTEMS OFFICE LEVEL L1—L4: ORDINARY HAZARD GP I CALCULATED .15/ 1500 S.F. — WET SYSTEM 2 2/2 HOSE VALVES PROVIDED AT ROOF OUTSIDE SOUTH STAIR TOWER ROOF HOSE VALVES CALCULATED FOR 500 GPM © 100 PSI WITH 250 GPM FOR 2ND STANDPIPE, 750 GPM TOTAL 150'I — 13/4" FIRE HOSE IN CABINET PROVIDED AT LEVELS 2 AND 4 NORTH AND SOUTH STAIRS QUICK RESPONSE SPRINKLERS UTILIZED THOUGHTOUT PROJECT SPRINKLER HEADS TO BE ALIGNED IN CEILING TILE 1"-2" THREADED PIPING TO BE 'DYNA—THREAD' 11/2" — 4" GROOVED PIPING TO BE 'DYNA—FLOW' / 6" GROOVED PIPING S10 DRY SYSTEM PIPING SLOPED TO DRAIN — 1/2" PER 10' FOR LINES / 1/4" PER 10' FOR MAINS CENTRAL STATION MONITORING PROVIDED BY OTHERS instry FIRE PROTECTION McKINSTRY-MAIN OFFICE 5005 3RD AVE SOUTH SEATTLE, WA. 98124 (206) 762-3311 McKINSTRY-PORTLAND OFFICE 5400 N.E. COLUMBIA BLVD PORTLAND,OR. 97218 (503) 331-0234 t% o Q o 7 Q 4" pC).o o C',.,DQP- a A' rk Q A PP CONCRETE POST -TENSION DECK Pr Gs D 0 d elO ACCEPTED Without Comments ❑ As Noted In Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this.acceptance and will require a resubmittal of revised drawings for subsequent approval. IIha f -Act l}`\g-i) subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: (1/9-0/0 Y By: O% rUKWILA FIRE DEPARTNvItIVt Please call: 575-4407 and give this job and exact address for shut• dvn or restoration approval_ O m N.C41 p a o. 'ANCHORTEK ULTRA PRE-SET CONCRETE INSERT' (3/8" EXCEPT 1/2" FOR EQ BRACING) W AIR = 4" AND SMALLER PIPE RING HANGER TYPICAL SPRINKLER PIPING HANGER NO SCALE DEPARTMENT OF HOMELAND SECURITY SEATTLE DISTRICT OFFICE F I L E 12500 TU ILA INTERNATIONAL BLVD. SEATTLE, WASHINGTON TENANT PLANS INDEX FP -1 4 4 SITE PLAN / NOTES FP -2 PARKING LEVEL 3 FP -3 PARKING LEVEL 2 FP -4 PARKING LEVEL 1 It FP -5 OFFICE LEVEL 1 FP -6 OFFICE LEVEL 2 k FP -7 OFFICE LEVEL 3 FP -8 OFFICE LEVEL 4 FP -9 ROOF PLAN FP -10 NORTH STAIR STANDPIPE FP -11 SOUTH STAIR STANDPIPE & STANDPIPE ISOMETRIC * INCLUDED IN TENANT SET McKINSTRY DIVISION: FIRE PROTECTION DRAWN BY: GB CHECKED BY: JOB NUMBER: -689" c'0 DATE: 9-30-03 SCALE: NOTED SHEET TITLE: Fire Sprinkler Plan Site Plan SHEET NUMBER: FP PLOT DATE: 9-22-04 DI JED SEP 2 d 2814 Z 3 1Z SPRINKLERS - THIS SHEET QTY 0 TYCO TY—FRB QUICK RESPONSE BRASS UPRIGHT 1/2" 155' 27 0 TYCO TY—FRB QUICK RESPONSE CHROME RECESSED PENDENT W/ CHROME RECESSED CANOPY 1/2" 165' 321 a TYCO TY—FRB QUICK RESPONSE CHROME RECESSED PENDENT 1/2" 165' 40 TOTAL: 388 THIS DOCUMENT HAS BEEN DESIGNATED AS DEPARTMENT OF JUSTICE, IMMIGRATION AND NATURALIZATION SERVICE "LIMITED OFFICIAL USE." MATERIAL MARKED AS LIMITED OFFICIAL USE MUST BE SAFEGUARDED AGAINST UNAUTHORIZED OR INADVERTENT DISCLOSURE. IT MUST BE STORED IN A LOCKED CONTAINER WHEN NOT IN USE AND DISPOSED OF BY SHREDDING OR BURNING WHEN NO LONGER USEFUL REPRODUCTION AND DISSEMINATION BEYOND THE RECIPIENT IS PROHIBITED WITHOUT PRIOR APPROVAL OF THE OFFICE OF SECURITY, SECURITY OPERATIONS SERVICES BRANCH, AT (202) 305-9999 OR THE ADMINISTRATIVE CENTER LAGUNA SECURITY OFFICE AT (949) 360-3178. 1 HOUR WALL 2 HOUR WALL NON-COMBUTIBLE ENTRY CANOPY .... NO STORAGE;BELOW REVISIONS: NO. DATE DESCRIP1IM4 0 LEVEL 1 SPRINKLER PLAN SCALE: 1/8" = 0 4' 8' ins fry FIRE PROTECTION McKINSTRY—MAIN OFFICE 5005 3RD AVE SOUTH SEATTLE, WA. 98124 (206) 762-3311 McKINSTRY—PORTLAND OFFICE 5400 N.E. COLUMBIA BLVD PORTLAND,OR. 97218 (503) 331-0234 16' 0 DEPARTMENT OF HOMELAND SECURITY SEATTLE DISTRICT OFFICE 12500 TUKWILA INTERNATIONAL BLVD. SEATTLE, WASHINGTON McKINSTRY DIVISION: FIRE PROTECTION GB DRAWN BY: CHECKED BY: JOB NUMBER: 689 DATE: 9-30-03 SCALE: 1/8 =1-0 SHEET TITLE: Fire Sprinkler Plan Level 1 SHEET NUMBER: FP5 PLOT DATE: 9-22-04 SPRINKLERS — THIS SHEET QTY O TYCO TY—FRB QUICK RESPONSE BRASS UPRIGHT 1/2" 155' TYCO TY—FRB QUICK RESPONSE CHROME RECESSED PENDENT 1/2" 165' 398 W/ CHROME RECESSED CANOPY TOTAL: 408 1 HOUR WALL 2 HOUR WALL REVISIONS: NO. DATE DESCRIPTION PIPING AT EL= 9'-814V EXCEPT AS NOTED LEVEL 2 SPRINKLER PLAN SCALE: 1/8" = 1'-0" 0 4' 8' ins fry FIRE PROTECTION McKINSTRY—MAIN OFFICE 5005 3RD AVE SOUTH SEATTLE, WA. 98124 (206) 762-3311 McKINSTRY—PORTLAND OFFICE 5400 N.E. COLUMBIA BLVD PORTLAND,OR. 97218 (503) 331-0234 THIS DOCUMENT HAS BEEN DESIGNATED AS DEPARTMENT OF JUSTICE, IMMIGRATION AND NATURALIZATION SERVICE "LIMITED OFFICIAL USE." MATERIAL MARKED AS LIMITED OFFICIAL USE MUST BE SAFEGUARDED AGAINST UNAUTHORIZED OR INADVERTENT DISCLOSURE. IT MUST BE STORED IN A LOCKED CONTAINER WHEN NOT IN USE AND DISPOSED OF BY SHREDDING OR BURNING WHEN NO LONGER USEFUL. REPRODUCTION AND DISSEMINATION BEYOND THE RECIPIENT IS PROHIBITED WITHOUT PRIOR APPROVAL OF THE OFFICE OF SECURITY, SECURITY OPERATIONS SERVICES BRANCH, AT (202) 305-9999 OR THE ADMINISTRATIVE CENTER LAGUNA SECURITY OFFICE AT (949) 360-3178. DEPARTMENT OF HOMELAND SECURITY SEATTLE DISTRICT OFFICE 12500 TUKWILA INTERNATIONAL BLVD. SEATTLE, WASHINGTON McKINSTRY OMSION: FIRE PROTECTION GB DRAWN BY: CHECKED BY: JOB NUMBER: 689 DATE: 9-30-03 SCALE: 1/8* = 1'-0" SHEET TITLE: Fire Sprinkler Plan Level 2 SHEET NUMBER: FP -6 PLOT DATE: 9-22-04 SPRINKLERS - THIS SHEET QTY 00 TYCO TY -FRB QUICK RESPONSE BRASS UPRIGHT 1/2" 155' 284 ® TYCO TY -FRB QUICK RESPONSE CHROME RECESSED PENDENT 1/2" 165' 69 W/ CHROME RECESSED CANOPY TOTAL: 351 THIS DOCUMENT HAS BEEN DESIGNATED AS DEPARTMENT OF JUSTICE, IMMIGRATION AND NATURALIZATION SERVICE "LIMITED OFFICIAL USE." MATERIAL MARKED AS LIMITED OFFICIAL USE MUST BE SAFEGUARDED AGAINST UNAUTHORIZED OR INADVERTENT DISCLOSURE. IT MUST BE STORED IN A LOCKED CONTAINER WHEN NOT IN USE AND DISPOSED OF BY SHREDDING OR BURNING WHEN NO LONGER USEFUL. REPRODUCTION AND DISSEMINATION BEYOND THE RECIPIENT IS PROHIBITED WITHOUT PRIOR APPROVAL OF THE OFFICE OF SECURITY, SECURITY OPERATIONS SERVICES BRANCH, AT (202) 305-9999 OR THE ADMINISTRATIVE CENTER LAGUNA SECURITY OFFICE AT (949) 360-3178. DinglaIMICSIMU 1 HOUR WALL LEVEL 3 SPRINKLER PLAN7 SCALE: 1/8" = 1' - REVISIONS: 0 4' 8' NO. DATE DESCRIPTION 16' instry FIRE PROTECTION McKINSTRY-MAIN OFFICE 5005 3RD AVE SOUTH SEATTLE, WA. 98124 (206) 762-3311 McKINSTRY-PORTLAND OFFICE 5400 N.E. COLUMBIA BLVD PORTLAND,OR. 97218 (503) 331-0234 F — F F F PIPING AT T-81/27 THIS LEVEL2 DEPARTMENT OF HOMELAND SECURITY SEATTLE DISTRICT OFFICE 12500 TUKWILA INTERNATIONAL BLVD. SEATTLE, WASHINGTON McKINSTRY DMSION: FIRE PROTECTION DRAWN BY: GB CHECKED BY: JOB NUMBER: 689 DATE: 9-30-03 SCALE: 1/8" = 1,-0" SHEET TITLE: Fire Sprinkler Plan Level 3 SHEET NUMBER: FP -7 PLOT DATE: 9-22-04 PRE-ACTION RISER DETAIL SPRINKLERS