HomeMy WebLinkAboutPP - 4817 S 136TH ST - RESIDENCE - PERMITS AND PLANS4817 S 136TH ST
ASSOCIATED PERMITS
D98-0199
City of Tukwila
FILE
John W. Rants Mayor
Fire Department Thomas P. Keefe, Fire Chief
August 12, 1998
Fire Department Review
Control #D98-0199
(511)
Re: Russell/Allen residence - 4817 South 136th Street
Dear Sir:
The attached set of building plans have been reviewed by
The Fire Prevention Bureau and are acceptable with the
following concerns:
1. For short plat development (four single family homes
or less), hydrants shall be placed so that a hydrant is
within 250 feet of a building. Distance from a hydrant to
a building is measured along the path of vehicular travel.
Fire hydrants shall conform to American Water Works
Association specifications C-502-54; it shall be
compression type, equipped with two 2 1/2" N.S.T. hose
ports and one 5" Storz pumper discharge port, and
shall have a 1 1/4" Pentagon open -lift operating nut.
All required hydrants and surface access roads shall
be installed and made serviceable prior to and during
the time of construction. (UFC 901.3)
2. Your street address must be conspicuously posted on
the building and shall be plainly visible and legible from
the street. Numbers shall contrast with their background.
(UFC 901.4.4)
Any overlooked hazardous condition and/or violation of the
adopted Fire or Building Codes does not imply approval of
such condition or violation.
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone(206) 575-4404 • Far (206) 575.44139
City of Tukwila
John W. Rants, Mayor
Fire Department Thomas P. Keefe, Fin' Chief
Page number 2
Yours truly,
The Tukwila Fire Prevention Bureau
cc: TFD file
ncd
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 57$4404 • Fax (206) 575-4439