Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 4815 S 136TH ST - LOT 4 - PERMITS AND PLANS
4815 S 136TH ST ASSOCIATED PERMITS 17-5-148 D17-0069 40$10, ' ' r� CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 SITE LOCATION FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 15 2 3 0 4 919 2 Site Address: 4 815 S. 136th ST Tukwila, WA 98168 Suite Number: Tenant Name: CARY LANG CONSTRUCTION INC 759999 Property Owner's Name: CARY LANG CONSTRUCTION INC 7 5 9 9 9 9 Mailing Address: 2 9 815 2 4TH AVE SW Floor: New Tenant? J - Yes ❑ - No FEDERAL WAY WA 98023 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: ANTHONY FURR Day Telephone: 253-840-9900 Company Name: RED HAWK FIRE PROTECTION LLC. Mailing Address: 801 VALLEY AVE NW SUITE D PUYALLUP WA 98371 ANTHONYF@REDHAWKFP . COM City State Zip E-mail Address: Fax Number: NICET III number: REDHAHF 90QP Contractor's City of Tukwila BUS -0 99754 9 Business License number: Total number of new/relocated devices or sprinkler heads: 2 9 NEW SPRINKLER HEADS Valuation of Project (contractor's bid price): $ 7 5 0 0 Scope of Work (please provide detailed information): Installation of an Automatic Fire Sprinkler System in a new single family residence, 29 heads, flow through design PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signatur • VI" Print Name: 4y Ere— Plan Permit App.doc Date: 07/12/2120' Day Telephone: 3 - $4-10 - 4 8/22/14 TFD FP Form 8 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit - 5 - PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: L07, 4_ Type of Inspection • v 1 Suite #: �I� S/47Address: sr ContactPerson: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: (r� 2/0 5e�c, Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Date: 1/2.///c6 IHrs.: I $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Dim -OoGI TP. ql/ PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: ti2rt.Li �� Tv, Type ofspection: u/ Address: Suite #: talc 9 /3if`" '3 j Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: ole 415 Cear Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: g7,- rync3 Date: ''/i I 1 '1 Hrs.: f . 0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 7 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: �j,�j/ N714 Sprinklers: Type of Inspection: /-4d-;'V Address: `'��, Suite #: r&/S - /54 f vr' Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: /►/o f/Aiv s 07%.1 5, Le /9A716 14116 /12-17_44-tf /Ogler igeriliz4/ 0-7-1 5;7142 - Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 4,. Date: 9/1/ ? Hrs.: G ! O $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Hydraulic Calculations for Project Name: MACADAM LOT 4 Location: 4815 S 136th St, , Tukwila, WA 98168 Drawing Name: Macadam Lot 4 Floorplans Design Remote Area Number: 1 Remote Area Location: Playroom Occupancy Classification: Residential Commodity Classification: House 13D Density: 0.050gpm/ft2 Area of Application: 900.00ft2 (Actual 222.53ft2) Coverage per Sprinkler: 324.00ft2 Type of sprinklers calculated: Pendent No. of sprinklers calculated: 2 Type of System: In -rack Demand: Hose Streams: Calculation Date: 7/19/2017 Wet Volume of Dry or PreAction System: N/A gpm at Node: N/A 0.0 gpm at Node: 1 Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 34.25 @ 52.088 Water Supply Information: Name of Contractor: RED HAWK FIRE PROTECTION LLC. Address: 1002 N. MERIDIAN, SUITE 100, BOX 227, Phone Number: 253-840-9900 Name of designer: Authority Having Jurisdiction: Notes: © M.E.P.CAD, Inc. Anthony Furr N/A U. WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Byron Richard Moye 9419-0815-C Red Hawk Fire Protection, L.L.C. REDHAHFQP AutoSPRINK® 12 v12.0.61.0 1 7/19/201711:01:39AM Page 1 'out 'ava'd'd'W OO "!J O'69'0'ZLA Z6 ®NNIbdSo;ny 1/W017:10:11. L I.OZ/6 4/L Pressure - psi 0 0 0 0 0 rn O O O O O O O 11111 I I I I I I I I 11111111/ 111111111 I I I I I I I I I I I I I I I I I I 111111111 111111111 I I I I I I I I I I I I I I I I I I I System demon( 34.25 @ 52.05 essure 75 iailable Su 4.25 @ 67. o/ - _ _ - - - O O O /O� a N O O O O Water Supply Summary Sheet Node: 1 :JagwnN easy a}owej LI•OZ/6l/L :a}ea 17101 INVOVOvW :aweN qof Summary Of Outflowing Devices Job Number: 80103 Report Description: Residential (1) Device Actual Flow (gpm) Minimum Flow (gpm) K -Factor (K) Pressure (psi) Density (qpmpft2) Sprinkler 101 17.25 17.00 4.9 12.399 0.053gpm/ft2 c Sprinkler 102 17.00 17.00 4.9 12.037 E> Most Demanding Sprinkler Data 0.052gpm/ftz LN © M.E.P.CAD, Inc. AutoSPRINK® 12 v12.0.61.0 7/19/2017 11:01:41AM Page 3 Job Name: MACADAM LOT 4 Remote Area Number: 1 Date: 7/19/2017 Supply Analysis Node Name(psi) Static Residual Flow (psi) e° (gpm) Available Total Demand (psi) @ (gpm) Required Pressure (psi) 1 Water Supply 75.000 20.000 100.00 67.422 34.25 52.088 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1 -0-9% Supply 52.088 34.25 101 17-1 Sprinkler 12.399 17.25 Density:0.053gpim/ftz 102 17-1 Sprinkler 12.037 17.00 Density:0.052gpm/ftz 2 -0-9% 46.400 3 -0-9% 37.585 4 1-6'/z 35.985 5 9-6 30.757 6 9-6 29.524 7 9-6 30.128 8 9-6 30.022 9 17-6 12.698 10 17-6 12.608 11 19-6 16.656 65 9-6 30.441 69 9-6 30.290 [�y© M.E.P.CAD, Inc. 111 AutoSPRINK® 12 v12.0.61.0 7/19/2017 11:01:42AM Page 4 Job Name: MACADAM LOT 4 Remote Area Number: 1 Date: 7/19/2017 Pipe Information Node 1 Elev 1 (Foot) K -Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length Len 9 (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 102 17-1 4.9 17.00 1 (See Notes) 3-1% 150 12.037 Route 1 Sprinkler, E(7-0), T(5-0) 12-0 0.050373 -0.190 10 17-6 17.00 1.1010 15-1% 0.761 10 17-6 1 (See Notes) 6-11% 150 12.608 E(7-0), T(5-0) 12-0 0.004753 9 17-6 4.75 1.1010 18-11% 0.090 9 17-6 17.25 1 (See Notes) 27-5'% 150 12.698 Flow (q) from Route 2 3E(7-0), Tr(1-0), 2T(5-0) 32-0 0.081156 -0.867 11 19-6 22.00 1.1010 59-5% 4.825 11 19-6 12.25 1 (See Notes) 19-4 150 16.656 Flow (q) from Route 6 Tr(1-0), 3E(7-0), 2Z, T(5-0) 27-0 0.184112 4.336 6 9-6 34.25 1.1010 46-4 8.533 6 9-6 1 (See Notes) 6-0 150 29.524 T(5-0) 5-0 0.112502 -0.004 5 9-6 26.25 1.1010 11-0 1.237 5 9-6 8.01 1 (See Notes) 7-7 150 30.757 Flow (q) from Route 3 f(-0.000), 2Tr(1-0), CV 2-0 0.184112 3.461 4 1-6% 34.25 1.1010 9-7 1.766 4 1-6% 11/4 (See Notes) 2-3% 150 35.985 E(8-0) 8-0 0.058348 0.999 3 -0-9% 34.25 1.3940 10-3% 0.601 3 -0-9% 2 (See Notes) 70-8 150 37.585 E(11-0), WMV(-8.000) 11-0 0.009986 2 -0-9% 34.25 2.0030 81-8 8.815 2 -0-9% 1 (See Notes) 18-10% 150 46.400 Water Supply 0.301431 - 1 -0-9% 34.25 0.9950 18-10% 5.688 0.00 52.088 Hose Allowance At Source Total(Pt) Route 1 1 34.25 101 17-1 4.9 17.25 1 (See Notes) 1-5% 150 12.399 Route 2 Sprinkler, E(7-0), Tr(1-0) 8-0 0.051774 -0.190 9 17-6 17.25 1.1010 9_5% 0.489 12.698 Total(Pt) Route 2 i+ © M.E.P.CAD, Inc. AutoSPRINK®12 v12.0.61.0 1 7/19/2017 11:01:43AM Page 5 Job Name: MACADAM LOT 4 Remote Area Number: 1 Date: 7/19/2017 Pipe Information Node 1 Elev 1 (Foot) K -Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 65 9-6 4.80 + 3.20 1 (See Notes) 13-8% 150 30.441 Route 3 Flow (q) from Route 4 and 5 E(7-0), T(5-0) 12-0 0.012511 -0.005 5 9 6 8.01 1.1010 25-8% 0.322 30.757 Total(Pt) Route 3 7 9-6 6.02 + 1.99 1 (See Notes) 7-9% 150 30.128 Route 4 Flow (q) from Route 7 and 8 T(5-0) 5-0 0.003 69 9-6 8.01 1.10100.012511 12-9% 0.160 69 9-6 1 (See Notes) 22-4 150 30.290 Tr(1-0) 3Tr(1-0), T(5-0) 9-0 0.004863 -0.002 65 9-6 4.80 1.1010 31-4 0.152 30.441 Total(Pt) Route 4 69 9-6 1 (See Notes) 43-4 150 30.290 Route 5 T(5-0) 2E(7-0), 4Tr(1-0) 23-0 0.002297 -0.002 65 9-6 3.20 1.1010 66-4 0.152 30.441 Total(Pt) Route 5 10 17-6 1 (See Notes) 103-9%z 150 12.608 Route 6 9Tr(1-0), 8E(7-0), 2T(5-0) 75-0 0.027494 -0.867 11 19 6 12.25 1.1010 178-9% 4.915 16.656 Total(Pt) Route 6 8 9 6 8.01 1 (See Notes) 11-4% 150 30.022 Route 7 Flow (q) from Route 9 3Tr(1-0) 3-0 0.007376 7 9-6 6.02 1.1010 14-4% 0.106 30.128 Total(Pt) Route 7 8 9-6 8.01 1 (See Notes) 68-3% 150 30.022 Route 8 T(5-0), Flow (q) from Route 9 5Tr(1-0), 4E(7-0), T(5-0) 43-0 0.000952 7 9-6 1.99 1.1010 111-3% 0.106 30.128 Total(Pt) Route 8 6 9-6 1 (See Notes) 21-9 150 29.524 Route 9 E(7-0), 2T(5-0), Tr(1-0) 18-0 0.012511 0.000 8 9-6 8.01 1.1010 39-9 0.497 30.022 Total(Pt) Route 9 © M.E.P.CAD, Inc. AutoSPRINK® 12 v12.0.61.0 1 7/19/2017 11:01:43AM Page 6 Job Name: MACADAM LOT 4 Remote Area Number: 1 Date: 7/19/2017 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) C Value Multiplier Actual Inside Diameter 4.87 = Factor Schedule 40 Steel Pipe Inside Diameter Value Of C 100 130 140 150 Multiplying Factor 0.713 1.16 1.33 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 111/4 Elbow Ee2 22W Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply 5CV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap © M.E.P.CAD, Inc. AutoSPRINK® 12 v12.0.61.0 1 7/19/2017 11:01:43AM Page 7 SITE PLAN 0 5 10 20 SCALE 1"=20'-0" ''i>:wt�Srn 40 SYMBOLS SCOPE OF WORK ❑ Without Comments As Noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Flre Prevention Bureau for conformance with current City standards. Acceptance is subjectto errors and omissions which do not authorize violations of adopted standards and ordinances The responsibility for the adequacy of desigr, I gists totally with the designer, Additions, deletions . evisions to these drawings after: this date will void th, , :,cceptance and will require a resubmittal of r<;1,1s I,rawings for subsequent approval. Final accept Ke to fleld test and inspection by The Tuk wNf! Date:� Bureau, ¥'J4y d►o rett;►ndl. Flow(b� t 4)Jre re TUKWILA FIRE DEPARTMENT Please call 206-5754407 and give this Fire Permit No" and exact shut- down or ntstoration /3pproval. TIGHTLINE TOTAL SQ: FT. 2,825 SQ. FT. MACADAM LOT 4 RHFP START POINT ©0-6AFF g- 1,_.\'-0%�0 COMPOSITION RodW/ a0° INTERWOVEN FELT ON 1/2" 2-1/O PLYWOOD SHEATHING ALL ROOF F=LASHING. TO 5E MIN: U., 6,4 6AL`r. eT€€L. ROOF DRIP EDGES PER SEC. RWS.2.8.5 PROVIDE DRIP EDGE AT EAVE°+ 4 GABLES W/ A MIN: 2' OvEPLAP. 2x SCREENED EAVE VENT BLOCKS W/C4) 214a° HOLES EACH - F'ROvIDE APPROVED INSULATION BAFFLE To Ei 'SURE I" .MILL AIR SPACE. 7_ir.J.GA.L._E.. tERIcs_1l1ALL (2)2xb TOP I£ --- 2x6 STUDS o 16" O.C.. I/2' SHT'G (4t=4 RATED 24/0.) AIR BARRIER EXTERIOR 51E3'1116- PM 1r 1116PER ELEVATION R=21 INSULATION W/ CONT. VAPOR eARRIEr3. (WARMLSIDE) GRADE n 1.£W ELEC. BELL 18'-9 NEW CITY CONNECTION BY OTHERS NEW 1" WATER METER BY OTHERS 10'-8 1 1 BY OTHERS 1/2 12 i (2) ATTIC SPACE MANUI° TRU55E9 24 O.C. SEE ROOF FRAMING PLAN 1 12 • R_4,1 INSULATION ATTIC VENTILATION AT LEAST 407o 4 NOT MORE THAN 50% OF REQUIRED VENTS SHALL BE IN UPPER PORTION OF VENTILATED ROOF FACE (NO MORE THAN 3' BELOW THE RIDGE OR HIGHEST POINT/ WITH THE BALANCE OF REQUIRED VENTILATION pROVIpEDT EAV€ VENTING. ti S1, r)FtoOM 2 FLOOR CONSTRUCTION.. 3/4' ,tSC PLYWOOD .SUES-F=LR. GLUED 4 NAILED TO (SEE FRAMING PLAN FOR SIZE AMID SPACIII&) DOOR UTILITY HALL NOOK FLOOR CONSTRUCTION: 3/4" TLCs PLTWOOD SUB -FL! GLUED 4 NAILED TO. (SEE FRAMING PLAN FOR. - SIZE AND SPACING) KITCHEN pFSK 2/4 CLG JST 24' O.G. DOOR TO POWDER ROOM PEAM FER`UPPER FLOOR FRM'G FLAN" CLOSET —6 2x8 LAFdp'G FOUNDATION DRAIN :...-.-= 4" DIA. PERF. PIPE PEA GRAVEL FILL • 6 MIL VI9QUEEN VAPOR BARRIER T4POUGtuOUT CFRAWLSPACE. LAE' FPLIC :5 12' MIN. • CRAIALSPACE R=38 INSULATION -- ' HIGH DENSITY \CRAWLSPACE - ACCESS RADE MIN Ul_.Z,II\LS SEC T Ic a/a" '- HYDRAULIC NODE GATE VALVE-N.R.S. (GV) ELECTRIC BELL EXISTING SPRINKLER PIPING NEW SPRINKLER PIPING BY OTHERS NEW SPRINKLER PIPING BYAPFP GENERAL NOTE; RED HAWK FIRE PROTECTION, LLC (RHFP) WILL PROVIDE ONE WET PIPE AUTOMATIC SPRINKLER SYSTEM TO PROTECT THE RESIDENTIAL LEVELS AND ONE DRY SYSTEM TO PROTECT THE BASEMENT CRAWL SPACE AND ATTIC FOR EXISTING GREENTREE, APARTMENT BUILDING D. RI -IFP WILL START WORK AT EXISTING 8" UNDERGROUND SUPPLY IN S. 136TH ST. ALL AREAS PROTECTED BY A WET SYSTEM MUST BE MAINTAINED BY OTHERS AT A MINIMUM 40°F TO PREVENT FREEZING. EXCLUSIONS PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT, ELECTRICAL WIRING OF ANY KIND INCLUDING BUT NOT LIMITED TO WATERFLOW SNITCH, ELECTRIC BELL, AND TAMPER SWITCHES CENTRAL STATION MONITORING EQUIPMENT, WIRING AND SERVICES CEILING AND WALL REMOVAL/REPLACE TO FACILITATE THE INSTALLATION OF THE SPRINKLER SYSTEM. 1. SPRINKLER SYSTEM DESIGN PER NFPA#13D. 2. ALL MATERIALS SHALL BE NEW AND UL AND/OR FM APPROVED. 3. FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH NFPA #13 AND SPECIFICATIONS. 4. IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT IS THE OWNERS RESPONSIBILITY TO PROVIDE HEAT THROUGH OUT THE WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE, DELUGE AND OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS. 5. FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF, THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE SPRINKLER SYSTEM OR ANY APPURTENANCES THEREOF. 6. ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING OR PATCHING TO BE BY OTHERS. 7. ALL PIPING IN RESIDENTIAL UNITS TO BE CPVC PIPE. 8. ALL THREADED PIPE TO BE SCHEDULE 40 BLACK JOINED WITH CAST IRON THREADED FITTINGS. 9. ALL WELDED PIPE TO BE SCHEDULE 10 BLACK JOINED WITH GROOVED FITTINGS. 10. ALL GROOVED COUPLINGS TO BE RIGID UNLESS NOTED OTHERWISE. 11. SEE FP 1.10 FOR SYSTEM STANDARD DETAILS. 12. ALL HANGERS FOR CPVC ARE TO BE PER DETAILS ON SHEET FP 1.10 (UNO). 13. ALL HANGERS FOR STEEL PIPE TO BE NO. 15W SAMMY SIDEWINDER (UNO) 14. ALL PIPE DIMENSIONS ARE CUT LENGTHS (UNO) 15. ALL DRY MAIN PIPING TO BE SLOPED AT 1/4" PER 10'-0" AND ALL DRY LINE PIPING TO BE SLOPED AT 1/2" PER 10'-0". 1" x 1' x 1" CPVC SPRINKLER HEAD TEE ... '.0J SPARE CABINET • 1"x 1"x1h° CPVC SPRINKLER HEAD TEE 1" x 1" x r CPVC SPRINKLER HEAD TEE 1" MALE CPVC ADAPTER 1" MALE CPVC ADAPTER —I I111 11111=1 IJJ1- 1--.:11111_771 MAINTAIN 2 ANNULAR CLEARANCE AROUND PIPE RISER DETAIL 0 1 2 SCALE 1/2”=1'-0" a . " BASE OFR1SER*N0DE2':° 1=I 1X11=Il1 11-11-111=L=L=tL1=I 411 I Ii„Ill � ISI I =ll_—III-111=ll=111--L�11- 11111111X —111-7---111=11r— MAINTAIN 111-111 RISER MATERIAL LIST ITEM I QTY SIZE DESCRIPTION 1 1 1 CHECK VALVE POTTER VSR-SF WATERFLOW SVdTICH GLOBE TEST AND DRAIN VALVE PRESSURE GUAGE 6 POTTER PBA246 6hd SPARE HEAD CABINET SPARE HEAD CABINET QTY SIZE DESCRIPTION yt ya GL4906 RESIDENTIAL SPRINKLER HEADS 155° GL5606 CONCEALED SPRINKLER HEAD 175° GL4431 QP SIDEWALL SPRINKLER HEAD 155° SPRINKLER HEAD WRENCH FOR G14906 SPRINKLER HEAD WRENCH FOR GL5606 SPRINKLER HEAD WRENCH FOR GL4431 DE.S!GN.CRITER[ PER NFPA 13D (2010), CITY OF TUKWILA. RM -01 (PLAYROOM) WET SYSTEM RESIDENTIAL DESIGN DENSITY: 0.05 GPM / MOST DEMANDING 2 HEADS rLOW TEST INFORMATION WATER FLOW HAS BEEN RESTRICTED WITH PRESSURE REDUCING VALVE BY OTHERS TO STATIC PRESSURE OF 75 PSI. SHALL BE MAINTAINED. CALCULATIONS MADE AT 75PSI STATIC PRESSURE: 155 PSI RESIDUAL PRESSURE 20 PSI RESIDUAL FLOW: 1100 GPM DRAWING INDEX FP 0.10 SITE PLAN AND NOTES FP 2.10 MAIN FLOOR FIRE SPRINKLER PLAN ;=P 2.20 UPPER FLOOR FIRE SPRINKLER PLAN VICINITYMAP 4815 South 136th Strut RED HAWK FIRE PROTECTION, LLC 801 VALLEY AVE NW, SUITE D PUYALLUP, WA 98371 PHONE: (253) 840-9900 FAx (800) 591-4382 WA CL# REDHAHF901 QP NICET Stamp 1 1 1 1 ■ 1 1 1 1 1 1 1 ■ WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Byron Richard Moye 9419-0815-C Red Hawk Fire Protection, L.L.C. REDHAHFQP Ionatu 07/24/2017 Date 1 1 1 Expires 12/31/17 1 1 1 1 1 1 1 ; 1 Approvals Required OWNER /ARCHITECT Revisions Contract With: CARY LANG CONSTRUCTION 29815 24TH AVE SW FEDERAL WAY, WA 98023 CARY LANG Phone: 2536616880 Fax: Contract Name: MACADAM LOT 4 4815S136thSt Tukwila, WA 98168 Drawing Title SITE PLAN AND NOTES Key Plan • Date: Job Number: Designer: Building Permit: July 21, 2017 80103 Anthony Furr Drawing No. FPOiI: PAID JUL 23 2017 TUKWIL'FIRE fer7 y5;6% MINIMUM DISTANCES FOR ORDINARY- AND INTERMEDIATE -TEMPERATURE RESIDENTIAL SPRINKLERS (NFPA 13D-202 TABLE 7.5.5.3) MINIMUM DISTANCE FROM EDGE OF SOURCE TO ORDINARY S(INCHES) MINIMUM DISTANCE FROM EDGE OF SOURCE TO INTERMEDIATE - SPRINKLER (INCHES) SIDE OF OPEN OR RECESSED FIREPLACE FRONT OF RECESSED FIREPLACE 801 VALLEY AVE NW, SUITE D PUYALLUP, WA 98371 PHONE: (253) 840-9900 FAX (800) 591-4382 WA CL# REDHAHF901 OP UNINSULATED HOT WATER PIPES SIDE OF CEILING- OR WALL - MOUNTED HOT AIR DIFFUSERS FRONT OF WALL- MOUNTED HOT AIR DIFFUSERS WASHINGTON STATE.' CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Byron Richard Moye 9419-0815-C Red Hawk Fire Protection, L.L.C. REDHAHFQP A LIGHT FIXTURE: 250W -499W Approvals Required OWNER /ARCHITECT "NO BLOCK" HANGER WOOD JOIST OR COMPOSITE WOOD JOIST HANGERS - PIPE HANGERS SHALL BE SIZED, SPI. ,ED AND INSTALLED AS REQUIRED BY NFPA STANDARDS NO OTHER PIPING AND/OR DEVICES ARE TO BF ATTACHED TO THE SPRINKLER PIPE HANGER SYSTEM UNLESS THE HANGER HAS BEEN SPECIFICALLY DESIGNED FOR THE ADDITIONAL LOADING. - THIS CONTRACT DOES NOT INCLUDE ANY MATERIAL OR DEVICES TO IMPROVE THE STRUCTURAL STRENGTH OF THE BUILDING TO ENABLE IT TO CARRY THE LOAD OF THE FIRE PROTECTION SYSTEM. - SEE DETAILS ON THIS SHEET FOR THE SPECIFIC HANGER ASSEMBLIES USED FOR THIS INSTALLATION. NFPA 13, 2010 Edition Table 9.2.2.1 MAXIMUM DISTANCE BETWEEN HANGERS (ft - in) CARY LANG CONSTRUCTION 2981.5 24TH AVE SW FEDERAL WAY, WA 98023 : CARY LANG Phone: 2536616880 Fax: Contract Name: MACADAM LOT 4 PIPE TYPE CPVC NOMINAL PIPE SIZE ( IN. 4815 S 136th St Tukwila, WA 98168 E.I/2" TYPE "X' GWE ON ALL WA M AND STRUCTURAL WALLS. (I) LAYERS 5/8 TYPE "X" ON CEILINGS. WIRAP ALL E%'POSED POSTS AND BEAMS IN I/2" TYPE: '`X" GWE Drawing Title MAIN FLOOR Sprinkler Legend Symbol Manufacturer SIN ;Type Size Response Orifice Finish Temperature K -Factor Quantity • Globe GL4906 Pendent 1/2 Quick 0" Brass 155°F 4.9 9 A) Globe GL5635 Pendent 1 Quick 0" White 155°F 5.6 6 Total = 15 1. LOWER CEILINGS TO BE 9-1 AFF. UPPER CEILINGS TO BE 8-1 AFF. UNLESS NOTED OTHERWISE. 2. PIPE FROM RISER TO UPPER FLOOR TO BE 1" CPVC, ALL OTHER PIPE TO BE 1" CPVC UNLESS NOTED OTHERWISE. 3. SPRINKLERS OMITTED FROM ALL CLOSETS MEETING THE REQUIREMENTS OF SECTION 8.6.3 OF NFPA 13D (2013) AREAS MARKED WITH HATCH 4. SPRINKLERS OMITTED FROM ALL BATHROOMS UNDER 55 FT2 PER SECTION 8.6.2 OF NFPA 13D (2013) AREAS MARKED WITH HATCH 5. ALL ROOMS WITH SINGLE HEAD COVERAGE SPACED AT 18'-0" X 18'-0" AND SPACES WITH MULTI -HEAD COVERAGE SPACED AT 18'-0" X 18'-0" Date: Job Number: Designer: Building Permit:• July 21, 2017 80103 Anthony Furr Drawing No, ED HAWK FIRE PROTECTION, LLC HANGER FIG 511 Remote Area 1 OCCUPANCY CLASSIFICATION Residential DENSITY 0.050gpm/ft2for 900.00ftz (Actual 222.53ft2) 801 VALLEY AVE NW, SUITE D PUYALLUP, WA 98371 PHONE: (253) 840-9900 FAX (800) 591-4382 WA CL# REDHAHF901 QP TOTAL WATER REQUIREDr: TOTAL PRESSURE REQUIRED BASE of RISER (gpm)' BASE of RISER (psi) SAFETY MARGIN (psi) 52 088 +15.333 (22.7%), Caution: it is important that the insulation be installed tight against the joists. In unheated areas, any spaces' or voids between the Insulation and the Joists causes the water in the fire sprinkler piping to freeze. HANGER FIG. 514 1 1/2 NICET Stamp • _ t 1 _ r t S - t 00 - S - - - - - - w - t 1 - •t - -' ■ WASHINGTON STATE ■ CERTIFICATE OF COMPETENCY III FIRE PROTECTION SPRINKLER SYSTEMS ▪ Byron Richard Moye I . 9419-0815-C Red Hawk Fire Protection, L.L.C. RED AHFQP 07/24/2017 Explrss ■ 12/31117 Approvals Required OWNER /ARCHITECT' — s as as ABM S 4 WOOD JOIST OR COMPOSITE WOOD JOIST 0 0 "NO BLOCK" HANGER Caution: For areas having temperatures' of 0°F (-18°C) or lowerf an additional batt of Insulation covering the joist and the fire sprinkler piping should be used:: If this is not done, freeze -ups can occur in tho spnnklor piping. HANGERS - PIPE HANGERS SHALL BE SIZED, SPACED AND INSTALLED AS REQUIRED BY NFPA STANDARDS. NO OTHER PIPING AND/OR DEVICES ARE TO BE ATTACHED TO THE SPRINKLER PIPE HANGER SYSTEM UNLESS THE HANGER HAS BEEN SPECIFICALLY DESIGNED FOR THE ADDITIONAL LOADING. - THIS CONTRACT DOES NOT INCLUDE ANY MATERIAL OR DEVICES TO IMPROVE THE STRUCTURAL STRENGTH OF THE BUILDING TO ENABLE IT TO CARRY THE LOAD OF THE FIRE PROTECTION SYSTEM. - SEE DETAILS ON THIS SHEET FOR THE SPECIFIC HANGER ASSEMBLIES USED FOR MINIMUM DISTANCES FOR ORDINARY -AND INTERMEDIATE -TEMPERATURE RESIDENTIAL SPRINKLERS (NFPA 13D-2002 TABLE 775.5.3) THIS INSTALLATION. NFPA 13, 2010 Edition Table 9.2.2,1 MAXIMUM DISTANCE BETWEEN HANGERS (ft- in) -JL=- HEAT SOURCE MINMUM DISTANCE FROM EDGE OF SOURCE TO ORDINARY - SPRINKLER (INCHES) MINIMUM DISTANCE FROM EDGE OF SOURCE TO INTERMEDIATE - SPRINKLER (INCHES) Contract With: CARY LANG CONSTRUCTION 29815 24TH AVE SW FEDERAL WAY, WA 98023 CARY LANG Phone: 2536616880 Fax: Contract Name: MACADAM LOT'S COAL- OR WOOD BURNING STOVE KITCHEN RANGE WALL OVEN HOT AIR FLUES PIPE TYPE CPVC 3/4 1 5-6 6-0 NOMINAL PIPE SIZE (IN. ) 1 1/4 1 1/2 2 2 1/2 3 6-6 7-0 8-0 9-0 10-0 mmmmm UNINSULATED HOT WATER PIPES SIDE OF CEILING- OR WALL - MOUNTED HOT AIR DIFFUSERS FRONT OF WALL - MOUNTED HOT AIR DIFFUSERS HOT WATER HEATER OR FURNACE 4815 S136th St. Tukwila, WA 98168 Sprinkler Legend Symbol Manufacturer . SIN Type Size Response Orifice Finish Temperature K -Factor Quantity Globe GL4906 Pendent '/2 Quick 0" Brass 155°F 4.9 14 Total = 14 1. LOWER CEILINGS TO BE 9-1 AFF. UPPER CEILINGS TO BE 8-1 AFF. UNLESS <. NOTED OTHERWISE. 2. PIPE FROM RISER TO UPPER FLOOR TO BE 1" CPVC, ALL OTHER PIPE TO BE 1" CPVC UNLESS NOTED OTHERWISE. Drawing Title UPPER FLOOR Key Plan 3. SPRINKLERS OMITTED FROM ALL CLOSETS MEETING THE REQUIREMENTS OF SECTION 8.6.3 OF NFPA 13D (2013) AREAS MARKED WITH HATCH 4. SPRINKLERS OMITTED FROM ALL BATHROOMS UNDER 55 FT2 PER SECTION 8.6.2 OF NFPA 13D (2013).AREAS MARKED WITH HATCH 5. ALL ROOMS SPACED AT 18'-0" X 18'=0" Date: Job Number:' Designer:' Building Permit 80103 Anthony Furr. Drawing No.