Loading...
HomeMy WebLinkAboutPP - 4801 S 136TH ST - MACADAM LOT 2 - PERMITS AND PLANS4801 S 136TH ST ASSOCIATED PERMITS 17-S-183 D17-0067 JETM SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 /7-S- /8 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 1523049131 Site Address: 4801 S 136TH ST Suite Number: Floor: Tenant Name: New Tenant? ❑ - Yes ❑ - No Property Owner's Name: CARY LANG CONSTRUCTION Mailing Address: 29815 24TH AVE SW FEDERAL WAY City WA, 98023 State Zip CONTACT PERSON -if there are questions about the submittal. Name: ANTHONY FURR Day Telephone: 253-840-9900 Company Name: RED HAWK FIRE PROTECTION Mailing Address: 801 VALLEY AVE SUITE D PUYALLUP WA 98371 ANTHONYF@REDHAWKFP.COM City State Zip E-mail Address: Fax Number: 800-591-4382 Contractor's City of Tukwila NICET III number: Business License number: REDHAHF901 QP Total number of new/relocated devices or sprinkler heads: 31 Valuation of Project (contractor's bid price): $ 7948 Scope of Work (please provide detailed information): INTALL NEW NFPA 13D FIRE SPRINKLER SYSTEM IN NEW SINGLE FAMILY RESIDENCE PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 10/3/17 Print Name: RED HAWK FIRE PROTECTION Day Telephone: 253-840-9900 Plan Permit App.doc 8/22/14 TFD FP Form 8 2 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: / Type of Inspection: //-1--- Address: 4jj Suite #:l l • /il' �'� Contact Person: Special Instructions: Occupancy Type: Phone No.: .A ------ Approved per applicable codes. nCorrections required prior to approval. COMMENTS: e/,f 2 n ;t5 . vd/ Z 14.0u1s Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: I Inspector: s,4— Date: //2.1/W Hrs.: 1 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 i INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 6tc,etda,,4._ (,(frf- Sprinklers: Type of Inspection: Cev-&---A-, Address: Suite #: 41D( S S. /56 57_____ Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: e5-11----- Date: /6/41 /7.--- lirs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Project Name: Drawingl Location: , , Drawing Name: Drawingl Design Remote Area Number: 01 Occupancy Classification: Commodity Classification: Hydraulic Calculations for Residential 18X18 HOUSE 13D Density: 0.050gpm/ft2 Area of Application: 900.00ft2 (Actual 292.63ft2) Coverage per Sprinkler: 324.00ft2 Type of sprinklers calculated: Pendent No. of sprinklers calculated: 2 17-s-4,3 Calculation Date: 7/12/2017 Type of System: WET - CPVC Volume of Dry or PreAction System: N/A In -rack Demand: N/A gpm at Node: N/A Hose Streams: 0.0 gpm at Node: 1 Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 34.01 @ 48.789 Water Supply Information: Name of Contractor: Address: Phone Number: Authority Having Jurisdiction: Notes: Automatic peaking results Name of designer: Left: N/A Right: 50.529 WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Byron Richard Moye 9419-0815-C Red Hawk Fire Protection, L.L.C. REDHAHFQP Ign 07/17/2017 Date i a &,© M.E.P.CAD, Inc. E] AutoSPRINK® 12 v12.0.54.0 01 7/12/2017 6:43:06PM Page 1 •oul'avodaW©'J O179.0.Zl•' Z6 ®71NRIdSo;ny Wd60:£17:9 LLOZ/ZI•/L N UI 0 01 0 cyl 0 0 0 O O cri O N O m O J 3 o O O O N N (J7 0 Pressure - psi O 0 0 0 O co 0 0 4_1_141111 IIIIIIIII IIIIIILLI IIIIIIIII 1111111 II111111111 IIIIIIIII IIIIIIIII 111111111 IIIIIIIII - System demand curve A Available Supply Static Pressure 75.000 34.01 c 74.911 A I - O L.w _ m - _ o 0 o 0 _ - N O O O O Water Supply Summary Sheet Node: 1 (D73 3 6 O N m 3 m v 0 c 3 5' sr (0 m O L60Z/Z6/L :a;ea X99 Summary Of Outflowing Devices Device Actual Flow (qpm) Minimum Flow (ppm) Job Number: 1 Report Description: Residential 18X18 (01) K -Factor (K) Pressure (psi) b Sprinkler 1001 17.00 17.00 4.9 12.037 Sprinkler 1002 17.01 17.00 4.9 12.050 b Most Demanding Sprinkler Data NL © M.E.P.CAD, Inc. hn AutoSPRINK® 12 v12.0.54.0 7/12/2017 6:43:11 PM Page 3 Job Name: Drawing1 Remote Area Number: 01 Date: 7/12/2017 Supply Analysis Node Name Static (psi) Residual Flow (psi) @ (gpm) Available Total Demand @ (psi) (gpm) Required Pressure (psi) 1 Water Supply 75.000 20.000 1100.00 74.911 34.01 48.789 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1 -3-0 Supply 48.789 34.01 1001 8-1 Sprinkler 12.037 17.00 1002 8-1 Sprinkler 12.050 17.01 2 0-6 34.236 101 9-6 25.506 102 9-6 26.803 103 9-6 28.054 111 9-6 26.088 201 8-7 12.104 202 8-7 12.117 203 8-7 14.091 204 8-7 15.147 211 8-7 14.215 © M.E.P.CAD, Inc.AutoSPRINK® 12 v12.0.54.0 7/12/2017 6:43:13PM Page 4 Job Name: DrawingI Remote Area Number: 01 Date: 7/12/2017 Pipe Information Node 1 Elev 1 (Foot) K -Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. Fitting (Foot) Pf Friction Loss Per Unit (Psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 1001 8-1 4.9 17.00 1 (See Notes) 0-6 150 12.037 Route 1 Sprinkler, T(5-0) 5-0 0.050373 -0.209 • 201 8-7 17.00 1.1010 5-6 0 276 201 8-7 1 (See Notes) 10-0 150 12.104 Tr(1-0) 1-0 0.001207 202 8-7 2.26 1.1010 11-0 0.013 202 8-7 17.01 1 (See Notes) 18-1 150 12.117 Flow (q) from Route 2 E(7-0), Tr(1-0), T(5-0) 13-0 0.063524 203 8-7 19.27 1.1010 31-1 1.974 203 8-7 1 (See Notes) 15-3% 150 14.091 Tr(1-0), T(5-0) 6-0 0.049595 204 8-7 16.86 1.1010 21-3% 1.056 204 8-7 17.15 1 (See Notes) 10-21/2 150 15.147 Flow (q) from Route 3 2E(7-0), 2T(5-0) 24-0 0.181685 4.147 101 9-6 34.01 1.1010 34-2% 6.212 101 9-6 1 (See Notes) 12-10 150 25.506 T(5-0) 5-0 0.072713 102 9-6 20.73 1.1010 17-10 1.297 102 9-6 5.92 1 (See Notes) 5-9% 150 26.803 Flow (q) from Route 4 T(5-0) 5-0 0.115727 103 9-6 26.65 1.1010 10-9% 1.251 103 9-6 7.36 1 (See Notes) 8-7 150 28.054 Flow (q) from Route 7 3Tr(1-0), f(-0.000), CV, cplg(1-0) 4-0 0.181685 3.894 2 0-6 34.01 1.1010 12-7 2 288 2 0-6 1% (See Notes) 93-6 150 34.236 E(9-0), WMV(-10.000), S 9-0 0.029608 1.517 1 -3-0 34.01 1.5980 102-6 13.035 0.00 48.789 Hose Allowance At Source Total(Pt) Route 1 1 34.01 1002 8-1 4.9 17.01 1 (See Notes) 0-6 150 12.050 Route 2 Sprinkler, T(5-0) 5-0 0.050423 -0.209 202 8-7 17.01 1.1010 5-6 0 276 12.117 Total(Pt) Route 2 ©M.E.P.CAD, Inc. AutoSPRINK® 12 v12.0.54.0 01 7/12/2017 6:43:16PM Page 5 Job Name: Drawing) Remote Area Number: 01 Date: 7/12/2017 Pipe Information Node 1 Elev 1 (Foot) K -Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length 9 (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device /Device E uivalent 9 (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. Fitting (Foot) Pf Friction Loss Per Unit Elev(Pe) Node 2 Elev 2 (Foot) Foot Total Flow (Q) Actual ID Total (Foot) (psi) Friction(Pf) 211 8-7 14.74 + 2.41 1 (See Notes) 12-2% 150 14.215 Route 3 (q) from Route 5 and 6 Tr(1-0), T(5-0) 6-0 0.051207 204 8-7 17.15 1.1010 18-2% 0.932 15.147 Total(Pt) Route 3 101 9-6 1 (See Notes) 12-3 150 25.506 Route 4 Tr(1-0), T(5-0) 6-0 0.031891 111 9-6 13.28 1.1010 18-3 0.582 111 9-6 1 (See Notes) 61-11 150 26.088 4E(7-0), 2T(5-0) 38-0 0.007156 102 9-6 5.92 1.1010 99-11 0.715 26.803 Total(Pt) Route 4 201 8-7 1 (See Notes) 33-7 150 12.104 Route 5 4T(5-0), Tr(1-0) 21-0 0.038680 211 8-7 14.74 1.1010 54-7 2.111 14.215 Total(Pt) Route 5 203 8-7 1 (See Notes) 50-10 150 14.091 Route 6 T(5-0) 4Tr(1-0), 3E(7-0), 2T(5-0) 40-0 0.001361 211 8-7 2.41 1.1010 90-10 0.124 14.215 Total(Pt) Route 6 111 9-6 1 (See Notes) 97-8% 150 26.088 Route 7 10E(7-0), 3T(5-0), Tr(1-0) 86-0 0.010700 103 9-6 7.36 1.1010 183-8% 1.966 28.054 Total(Pt) Route 7 �t ©M.E.P.CAD, Inc. AutoSPRINK® 12 v12.0.54.0 01 7/12/2017 6:43:16PM Page 6 Job Name: Drawingl Remote Area Number: 01 Date: 7/12/2017 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) •[C Value MultiplierII Actual Inside Diameter4.87 = Factor Schedule 40 Steel Pipe Inside Diameter ) Value Of C 100 130 140 150 Multiplying Factor 0.713 1.16 1.33 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 11'/4 Elbow Ee2 22W Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap L© M.E.P.CAD, Inc. AutoSPRINK® 12 v12.0.54.0 01 7/12/2017 6:43:16PM Page 7 SITE PLAN Qi\o 10 20 40 SCALE 1"=20'-0" SYMBOLS SCOPE OF WORK "Z ® Without Comments As Noted in Red ®- Per The Attached Letter / These plans have been reviewed by 'i he Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject tau errors and omissions which r.10 not:' i.ithorize ‘rloIatiorl., or a copted standards and ordina ces•: The respunslblllt:y for the adequacy of desk ', totally with tt,e designer. Additions, deletiorle t :visions to these drawing` after this date will void tryi « 'ceptance and will require a resubmittal o revl. =4y' rawtngs for subsequent a , royal. Final acceptance is $+.1oject to Held test and Inspe ion by The Tukwila`Firt� Prevention Bureau. Date: IQ -3-1 i By: I fns -),%II 42,4e-,.1•7- WPele,rh►•► sell ) y d ro r e4 t✓► re TUKWILA FIRE Please //^^�,II 2I05- ti:✓ ri give this Hi" : r' end exact address fd ° shut gown or restoration appro al. :PARTMN" 4107'and -nit No. 73 0 -D 73rn r rn t.IIFF'rr r1.rlOf?.:.:......: ...........: I MAIN FLO0t? S 136TH ST cri NEW CITY CONNECTION BY OTHERS. m BUILDING CROSS SECTION SCALE NTS NEW 1" WATER METER / BY OTHERS co 0 pam ctt z .. 2 PROPERTY LINE C TOTAL SQ: FT.: 2,575 SQ. t%t7KM2 exEAr PM - RHFP START POINT; 0-6 AFF HALL =T' torr NEW ELEC. BELL `TYP CONCEALED SPRINKLER HEAD mum TYP SPRINKLER PIPE IMINI INN HYDRAULIC NODE GATE VALVE-N.R.S. (GV) ELECTRIC BELL EXISTING SPRINKLER PIPING NEW SPRINKLER PIPING BY OTHERS NEW SPRINKLER PIPING BY APFP GENERAL NOTE: RED HAWK FIRE PROTECTION, LLC (RHFP) WILL PROVIDE ONE WET PIPE AUTOMATIC SPRINKLER SYSTEM TO PROTECT THE NEW RESIDENCE. RHFP WILL START WORK AT EXISTING 1 1/4" UNDERGROUND SUPPLY LOCATED IN THE GARAGE. ALL AREAS PROTECTED BY A WET SYSTEM MUST BE MAINTAINED BY OTHERS AT A MINIMUM 40°F TO PREVENT FREEZING. EXCLUSIONS PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT ELECTRICAL WIRING OF ANY KIND INCLUDING BUT NOT LIMITED TO WATERFLOW SWITCH, ELECTRIC BELL, AND TAMPER SWITCHES CENTRAL STATION MONITORING EQUIPMENT, WIRING AND SERVICES CEILING AND WALL REMOVAL/REPLACE TO FACILITATE THE INSTALLATION OF THE SPRINKLER SYSTEM. UNDERGROUND WORK OF ANY KIND 1. SPRINKLER SYSTEM DESIGN PER NFPA#13D 2013. 2. ALL MATERIALS SHALL BE NEW AND UL AND/OR FM APPROVED. 3. FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH NFPA#13D (2010) AND SPECIFICATIONS. 4. IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT IS THE OWNERS RESPONSIBILITY TO PROVIDE HEAT THROUGH OUT THE WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE, DELUGE AND OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS. 5. FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE SPRINKLER SYSTEM OR ANY APPURTENANCES THEREOF. 6. ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING OR PATCHING TO BE BY OTHERS. 7. ALL PIPING IN RESIDENTIAL UNITS TO BE CPVC PIPE. 8. ALL THREADED PIPE TO BE SCHEDULE 40 BLACK JOINED WITH CAST IRON THREADED FITTINGS: 9, ALL WELDED PIPE TO BE SCHEDULE 10 BLACK JOINED WITH GROOVED FITTINGS. 10. ALL GROOVED COUPLINGS TO BE RIGID UNLESS NOTED OTHERWISE. 11. SEE FP 1.10 FOR SYSTEM STANDARD DETAILS. 12. ALL HANGERS FOR CPVC ARE TO BE PER DETAILS ON SHEET FP 2.10-30 (UNO). 13. ALL HANGERS FOR STEEL PIPE TO BE NO. 15W SAMMY SIDEWINDER (UNO) 14. ALL PIPE DIMENSIONS ARE CUT LENGTHS (UNO) 15. ALL DRY MAIN PIPING TO BE SLOPED AT 1/4" PER 10'-0" AND ALL DRY LINE PIPING TO BE SLOPED AT 1/2" PER 10'-0". 1" x 1" x 1" CPVC SPRINKLER HEAD TEE -..., 4,..(r sr— Iii-�li Illlf�lll II_I ;ill II III MAINTAIN 2" ANNULAR CLEARANCE AROUND PIPE SER DETAIL 2 SCALE 1/2"=1'-0" ii SPARE CABINET 1"x 1" x %" CPVC SPRINKLER HEAD TEE 1" x 1" x1" CPVC SPRINKLER HEAD TEE 1" MALE CPVC ADAPTER 1" MALE CPVC ADAPTER BASE OF RISER@NODE 2 III [II II!_Ili,.11I�II��II.i tfF III .III F. RISER MATERIAL LIST ITEM # QTY SIZE DESCRIPTION 1 CHECK VALVE POTTER VSR-SF WATERFLOW SWTICH 1 GLOBE TEST AND DRAIN VALVE 3" PRESSURE GUAGE 6 POTTER PBA246. 6 1 6hd SPARE HEAD CABINET SPARE HEAD CABINET QTY SIZE DESCRIPTION Ya GL4906 RESIDENTIAL SPRINKLER HEADS 155° 1h GL5606 CONCEALED SPRINKLER HEAD 175° GL4431 QR SIDEWALL SPRINKLER HEAD 155° SPRINKLER HEAD WRENCH FOR GL4906 SPRINKLER HEAD WRENCH FOR GL5606 YR 1_1 ESIGN CRITERIA PER NFPA 13D (2013), CITY OF TUKWILA: RM -01 (RESIDENCE) WET SYSTEM RESIDENTIAL DESIGN DENSITY: MOST DEMANDING 2 HEADS 18x18 MAX SPACING 17GPM/SPRINKLER PER MANUFACTURER KLOW TEST INFORMATION WATER FLOW INFORMATION HAS BEEN PROVIDED BY KING COUNTY WATER DISTRICT 125. STATIC PRESSURE: 155 (FLOW RESTRICTED TO 75 PSI) RESIDUAL PRESSURE 20 PSI RES:DUAL FLOW: 1100 GPM DRAWING INDEX FP 0.10 FP 2.10 FP 2.20 SITE PLAN AND NOTES. MAIN FLOOR FIRE SPRINKLER PLAN UPPER FLOOR FIRE SPRINKLER PLAN VICINITY MAP At NT OWN I,A,E•. $t er . ... �'sk , t 2.1rh tit tt4 St .i. Gateway orporate Center st:ra�c { F LATutA 1136th Ss '• 41t81 South 136th StrNI ti .,2,:11,1 OD Tac Rental rac;Hly N h5 11(ft'., 121.h Stor(ire Sports t7 King Co'Jnty 5 .: Treatmeatf Tukwila Community t7eti erpprnentDepart RED HAWK FIRE PROTECTION, LLC 801 VALLEY AVE NW, SUITE D PUYALLUP WA 98371 PHONE: (253) 840-9900 FAx (800) 591-4382 WA CL# REDHAHF9OlOP NICET Stamp P WASHINGTON STATE 11 CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS II Byron Richard Moye • 9419-0815-C " i RED Red HaAHFwk QPFire Protection, L.L.C.• • •• ■ ., ['"t Explros I, Ignatu 07/17/2017 Date 1..12(31/17 I/ Approvals Required CITY OF TUKWILA OWNER / ARCHITECT Revisions Contract With: CARY LANG CONSTRUCTION 29815 24TH AVE. SW FEDERAL WAY, WA 98023 CONTACT: CARY LANG Phone: 206-423-5055 Fax: Contract Name: MACADAM LOT 2 4801 S 136TH ST TUKWILA, WA Drawing Title SITE PLAN AND NOTES Key Plan Date: ' July 13, 2017. Job Number: Designer: Building Permit: KYLE WHITT Drawing No. FP 0.10 PAID COT "3 201? TUKWILA FIRF Ce MAT PM KITCHEN C'ANI3Y. PINING WOOD JOIST OR COMPOSITE WOOD JOIST 1. ALL CEILINGS TO BE 9-0 UNO 2 ALL PIPE TO BE 1" CPVC UNO 3. SPRINKLERS OMITTED FROM ALL CLOSETS MEETING THE REQUIREMENTS OF SECTION 8.6.3 OF NFPA 13D (2013) AREAS MARKED WITH HATCH 4. SPRINKLERS OMITTED FROM ALL BATHROOMS UNDER 55 FT2 PER SECTION 8.6.2 OF NFPA 13D (2013) AREAS MARKED WITH HATCH Sprinkler Legend Symbol Manufacturer Response Type SIN K -Factor Size Temperature Finish Escutcheon Spacing Discharge Quantity • Globe Quick Pendent GL4906 4.9 '/Z 155°F , Bronze CONC WHITE 18X18 17GPM 12 �) Globe Quick Pendent GL5635 5.6 1 155°F Bronze CONC WHITE 225SQ FT NA 4 LIGHT FIXTURE: 250W -499W . 12 6 Total = 16 Caution: It is important that the insulation be installed tight against the'. joists, In unheated areas, any spaces' or voids between the insulation and the joists causes the water in the fire sprinkler piping to freeze. Caution: For areas having temperatures of 0°F (-18°C) or lower, an additional batt of insulation covering the joist and the fire sprinkler piping should be used: If this is not done, freeze -ups can occur in the sprinkler piping, HANGERS - PIPE HANGERS SHALL B+E SIZED, SPACED AND INSTALLED AS REQUIRED BY NFPA STANDARDS NO OTHER PIPING AND/OR DEVICES ARE TO BE ATTACHED TO THE SPRINKLER PIPE HANGER SYSTEM UNLESS THE HANGER HAS BEEN SPECIFICALLY DESIGNED FOR THE ADDITIONAL LOADING. - THIS CONTRACT DOES NOT INCLUDE ANY MATERIAL OR DEVICES TO IMPROVE THE STRUCTURAL STRENGTH OF THE BUILDING TO ENABLE IT TO CARRY THE LOAD OF THE FIRE PROTECTION SYSTEM. - SEE DETAILS ON THIS SHEET FOR THE SPECIFIC HANGER ASSEMBLIES USED FOR THIS INSTALLATION. NFPA 13, 2013 Edition Table 9,2,2.1 MAXIMUM DISTANCE BETWEEN HANGERS (ft- in PIPE TYPE CPUC NOMINAL PIPE SIZE ( IN. ) MINIMUM DISTANCES FOR ORDINARY- AND INTERMEDIATE -TEMPERATURE RESIDENTIAL SPRINKLERS (NFPA 13D-2013 TABLE 7.5.5.3) = HEAT SOURCE MINIMUM_MINIMUM DISTANCE FRO " EDGE OF SOURCE TO ORDINARY- SPRINKLER (INCHES) DISTANCE FROM EDGE OF SOURCE TO INTERMEDIATE - SPRINKLER (INCHES) SIDE OF OPEN OR RECESSED FIREPLACE ' 36 12 FRONT OF RECESSED FIREPLACE 60 36 COAL- OR WOOD -42 BURNING STOVE . 12 KITCHEN RANGE 18 9 WALL OVEN 18 9 HOT AIR FLUES 18 9 UNINSULATED HEAT DUCTS 18 y UNINSULATED HOT WATER PIPES 12 6 SIDE OF CEILING- OR WALL- MOUNTED HOT AIR DIFFUSERS 24 12 FRONT OF WALL- MOUNTED HOT AIR DIFFUSERS 36 18 HOT WATER HEATER OR FURNACE g 3 LIGHT FIXTURE: OW -250W 6 3 LIGHT FIXTURE: 250W -499W . 12 6 RED HAWK FIRE PROTECTION, LLC tfroo Vittia/(e 801 VALLEY AVE NW, SUITE D PUYALLUP, WA 98371 PHONE: (253) 840-9900 FAx (800) 591-4382 WA CL# REDHAHF901 OP WASHINGTON STATE a CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS .: 1 Byron Richard Moye 9419-0815-C i Red Hawk Fire Protection, L.L.C. REDHAHFQP;' 07/17/2017 ly` Expires �i Ignatu Date 11,,,112J31/17 a Approvals Required CITY OF TUKWILA OWNER / ARCHITECT Revisions Contract With: CARY LANG CONSTRUCTION 29815 24TH AVE. SW FEDERAL WAY, WA 98023 CONTACT: CARY LANG Phone: 206-423-5055 Fax: Contract Name; MACADAM LOT 2 4801 S 136TH ST TUKWILA, WA Drawing Title MAIN FLOOR FIRE SPRINKLER PLAN Key Plan Date: Job Number: Designer: Building Permit; July 12, 2017 1, KYLE WHITT Drawing No. HANGER FIG. 511 801 VALLEY AVE NW, SUITE D PUYALLup, WA 98371 PHONE: (253) 840-9900 FAX (800) 591-4382 WA CL# REDHAHF901OP MS1P 012PM WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Byron Richard Moye 9419-0815-C Red Hawk Fire Protection, L.L.C. REDHAHFQP 07/17/2017 ("Expires Data 12!31117 Approvals Required CITY OF TUKWILA OWNER / ARCHITECT Revisions HYDRAULICALLY MOST DEMANDING Remote Area 01 OCCUPANCY CLASSIFICATION ' Residential 18X18 TOTAL WATER REQUIRED . 34.01 TOTAL PRESSURE REQUIRED, 48.789 BASE of RISER (gpm) 34.01 BASE of RISER (psi) 48.789` SAFETY MARGIN (psi) +26.123 (34.9%) "NO BLOCK" HANGER PINING AIZrIA' WOOD JOIST OR COMPOSITE WOOD JOIST LE..I5wr I,OFf • HANGERS - PIPE HANGERS SHALL BE SIZED, SPACED AND INSTALLED AS REQUIRED BY NFPA STANDARDS - NO OTHER PIPING AND/OR DEVICES ARE TO BE ATTACHED TO THE SPRINKLER PIPE HANGER SYSTEM UNLESS THE HANGER HAS BEEN SPECIFICALLY DESIGNED FOR THE ADDITIONAL LOADING. THIS CONTRACT DOES NOT INCLUDE ANY MATERIAL OR DEVICES TO IMPROVE THE STRUCTURAL STRENGTH OF THE BUILDING TO ENABLE IT TO CARRY THE LOAD OF THE FIRE PROTECTION SYSTEM. SEE DETAILS ON THIS SHEET FOR THE SPECIFIC HANGER ASSEMBLIES USED FOR THIS INSTALLATION. NFPA 13, 2013 Edition Table 9.2.2.1 MAXIMUM DISTANCE BETWEEN HANGERS (ft - in) PIPE TYPE CPVC NOMINAL PIPE SIZE ( IN. )' 29815 24TH AVE. SW FEDERAL WAY, WA 98023 CONTACT: CARY LANG Phone: 206-423-5055 Fax: Contract Name: SCALE 1/4"=l'-0" 1. ALL CEILINGS TO BE 8-1 UNO 2. ALL PIPE TO BE 1" CPVC UNO 3. SPRINKLERS OMITTED FROM ALL CLOSETS MEETING THE REQUIREMENTS OF SECTION 8.6.3 OF NFPA 13D (2013) AREAS MARKED WITH HATCH 4. SPRINKLERS OMITTED FROM ALL BATHROOMS UNDER 55 FT2 PER SECTION 8.6.2 OF NFPA 13D (2013) AREAS MARKED WITH HATCH Caution: It is important that the insulation be installed tight against the joists. In unheated areas, any spaces or voids between the insulation and the joists causes the water in the fire sprinkler piping to freeze. Sprinkler Legend Symbol Manufacturer Response Type SIN K -Factor Size Temperature Finish Escutcheon Spacing Discharge Quantity • Globe Globe Quick Quick Pendent Pendent GL4906 GL5606 4.9 5.6 1 �/ 155°F - 155°F Bronze Bronze CONC WHITE CONC WHITE 18X18 ' 17GPM - 14 225SQ FT NA 1 12 FRONT OF WALL MOUNTED HOT AIR DIFFUSERS 36 18 HOT WATER HEATER OR FURNACE 6 3 LIGHT FIXTURE: 0W -250W ti 3 LIGHT FIXTURE: 250W -499W 12 Total = 15 Caution: For areas having temperatures of 0°F (-18°C) or lower, anadditional beta of insulation covering theadditjoist and the fire sprinkler piping should be used. If this is not done, freeze -ups can occur in the sprinkler piping. MINIMUM DISTANCES FOR ORDINARY- AND INTERMEDIATE -TEMPERATURE RESIDENTIAL SPRINKLERS (NFPA 13D 2013 TABLE 7 5.5.3)::; HEAT SOURCE MINIMUM DISTANCE FROMDISTANCE EDGE OF SOURCE TO ORDINARY- SPRINKLER (INCHES) MINIMUM FROM EDGE OF SOURCE TO INTERMEDIATE. SPRINKLER (INCHES) SIDE OF OPEN OR RECESSED FIREPLACE 36 12 FRONT OF RECESSED FIREPLACE g0 36 COAL- OR WOOD -42 BURNING STOVE 12 KITCHEN RANGE 18 9 WALL OVEN 18 9 HOT AIR FLUES 18 9 UNINSULATED HEAT DUCTS 18 9 UNINSULATED HOT WATER PIPES 12 6 SIDE OF CEILING- OR WALL- MOUNTED HOT AIR DIFFUSERS 24 12 FRONT OF WALL MOUNTED HOT AIR DIFFUSERS 36 18 HOT WATER HEATER OR FURNACE 6 3 LIGHT FIXTURE: 0W -250W ti 3 LIGHT FIXTURE: 250W -499W 12 6 Key Plan Date: Job Number: Designer: Building Permit: July 12, 2017 KYLE WHITT