Loading...
HomeMy WebLinkAboutPP - 2916 S 135TH ST - SHAGLANI RESIDENCE - PERMITS AND PLANS2916 S 135TH ST ASSOCIATED PERMITS 14-5-264 D16-0105 D13-0157 4:644kA"444 grtr SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Site Address: 1°1% `o S ()S **PLEASE PRINT** King Co. Assessor's Tax No.: •"7 10. 660114 Suite Number: Floor: Tenant Name: c New Tenant? ❑ - Yes ❑ - No Property Owner's Name: S4 hJe# Sift Mailing Address: 1 *To 11.41) Ave 3 ti,t4fri W'I 'fj/61 CONTACT PERSON -if there are questions about the submittal. City State Zip Name: �e"l 1 1" t oeh Day Telephone: 3 t- 7 -('-7 471.6 WOI " Company Name: "- 'V"`th i, Mailing Address: 't 5)-' V' 3v a phVez WA VIII— • City State Zi E-mail Address: 1 p �) c ree,ofecti • C�'1� Fax Number: �b� — 7�I �' 1j O�O Total number of new/relocated devices or sprinlder heads: " 1 Valuation of Project (contractor's bid price): $ Poo Scope of Work (please provide detailed information): 3r4 1( nom✓' N t ` A I2' tx+41k .17,3te"v) PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN OR AUTHORIZED AGENT: Signature:"' `' •-............._ Day Moot-, Daate: WPM I + �/� Print Name: T o �1 Day Telephone: 360-7 ( 713.6 3.6 Plan Permit App.doc 1/2/13 TFD FP Form 8 4 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 4s -z cto. 13 c`si PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 1 (51.(v=,,,,, �—�— 11�1 , \ 4s Type of Inspection: e / 5" --cit.. a�, Ft rt le Address:...,,,,Contact Suite#: ti i `35.-±1.. Person: 1 Special Instructions: -Lk a -V.1,, kif'.,-1 Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: CD Sprinklers: ',e, f Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: DsP cke✓« C.. bL.. '‘ -Lk a -V.1,, kif'.,-1 c Orr e-t:tiA. ?z.v.. cit..' .= L Needs Shift Inspection: Sprinklers: ',e, f Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: c 51 Date: C I Lea 1c. Hrs.: cam• $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 3 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Je--s - 2 ( l• o IoS 1)11-tS PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: sKn fes, Sprinklers: Fire Alarm: Type of Inspection: plr Address: Suite #: Z91 b S . 1 35' %-t-, Contact Person: Special Instructions: Phone No.: Approved per applicable codes. KCorrections required prior to approval. COMMENTS: �w t� -� ,�S t,lr\ NSwf- Cir P P1 P-R- Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector`: _,� Date: Co /2;34(j. Hrs.: ('V $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F,D. Form F.P. 113 z INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /q-5-Z6Y t•I3 --is-) PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 1 � � hunt Ri2.-S Type (4.f Inspection: f7/✓i 1 Address: Suite#: 2!",'4 5 13eN ST Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: /1vS/.G //t-Gdil Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 'L Date: 51/3//4 Hrs.: /. a $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from ty of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip:: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 1 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit ce:31.tiq CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 � 4/-S -Z6K �3- ►s'L PERMIT NUMBERS W0 liceProject: rj /'� Fire Alarm: Type of spectionL• t.��T 4 Y. c- / Gi, Address: Suite #: 2 g/Co i35A 5, -- Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: tiy Wiezzei •0494-55 260 ;i ,4,- . aye-/ � ��.�- % — /9A -Ss 00.00 -vg //v Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: -----9!' 7 ,/ f (3 Date: 7I V//y I Hrs.: o ..it $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 w R Inspector: INSPECTION REQUEST FORM Date of call: L-0 S /2 1 l Time: 2- er Contact Name: WAV��PV1 Company Name: UO L\ k(J V MCti D V\ Phone: 1-12S— 23 °I- S' WO Cell: Project Name: Shan t Lcw 1 ? Project Address: 36;11 1- 5 S1 Permit#: �i"�-2LOLi Date inspection scheduled for: Wanks �ef�a� �d 4lta ,mss 61 ((5D Type of inspection requested: ❑ - Cover 0- Emergency lighting ❑ - Fire Alarm Ep- Fire Final ❑ - Fire Lane ❑ - Hydro ❑ - Hood & Duct ❑ - HVAC ❑ - Other O - Keybox ❑ - Mechanical ❑ - Racks ❑ - Roofing (Hot works) O - Spray booth ❑ - Sprinkler ❑ - Tank ❑ -Ten CIA,c,3,c‘ S v t 10 k 0 % 4 IMPORTANT NOTICE � /1-fdd 4111 Because of increased demand our inspectors' schedules are booked 3-7 days ahead. Therefore, you will need to call 206-575-4407 to schedule your inspections a minimum of 48 hours in advance of the date you want an inspection. Inspection Request Form.doc New 12/7/07 T.F.D. Form FP 95 - zc s(35's�, FILE Tukwila Fire Prevention Bureau Al Metzler, Fire Project Coordinator Fire Prevention Bureau Review Memo Date: Project Name: Address: Permit #: Plan Reviewer: May 13, 2013 Singh Residence 2916 S 135th St D13-157 Al Metzler, Fire Project Coordinator The Fire Prevention Bureau conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. 1. Please provide a complete, to scale, site plan which shows the location of the nearest fire hydrant by vehicular travel and the point at which the access road for the house leaves the public street (S. 135th St.) Should there be questions concerning the above requirements, contact the Fire Prevention Bureau at 206-971-8718. No further comments at this time. li Shaglani Residence Drawing Date:11/7/2014 11/10/14 9:38 Job Name: Location: Drawing Date: Contractor: HYDRAULIC DESIGN INFORMATION SHEET Shaglani Residence 2916 S 135th St Tukwila, WA 98168 11/7/2014 Wolfe Fire Protection, Inc. 17321 Tye St SE #B Monroe, WA 98272 Designer: Jeff Moen Calculated By:SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: VB Reviewing Authorities:City of Tukwila Remote Area Number: 1 Telephone:360-794-7926 Occupancy:Residential SYSTEM DESIGN Code:NFPA 13D Hazard:RESIDENTIAL System Type:WET Area of Sprinkler Oper. Density (gpm/sq ft) Area per Sprinkler Hose Allowance Inside Hose Allowance Outside sq ftl 1.000 13.0 sq ftl 0 gpm 1 0 gpm 1 Sprinkler or Nozzle Make: Reliabl Model: RFC K -Factor: 4.30 Temperature Rating: 155 CALCULATION SUMMARY 2 Flowing Outlets gpm Required: 26.1 psi Required: 44.6 @ Source WATER SUPPLY Water Flow Test Date of Test Static Pressure Residual Pres At a Flow of Elevation 80.0 psi 20.0 psi 500 gpm 0" Pump Data Rated Capacity 0 gpm Rated Pressure 0.0 psi Elevation 0 Make: Model: Location: Source of Information: SYSTEM VOLUME 15 Gallons Notes: g MN R. Moen 18131 -0209 -CF iiii Wolfe Fire Protection, l WOLFEFP908DD 1 1 • 1 E E._._ 0 Q Q to to drnOQa. CO CO COA- M NNtri Oj 0 u) O N 0 0 O CO • O O CV 0 0 0 O 0 O O M O 1.0 N O 0 N Shaglani Residence Drawing Date:11/7/2014 11/10/14 9:38 HYDRAULIC CALCULATION DETAILS QTY DESCRIPTION HYDRAULIC FLOW LOSS LENGTH C ID gpm psi TOTALS Hydr Ref W Required at Hyd Area 1 26 3 1-1/4" CPVC 90 Ell CPVC 18' 120 1.380 26 1.6 Elevation Change 13'0" 5.6 1 1'" Grvd Back Flow Valve Ames 200 CHART LOSS 26 4.5 3 1-1/4" Sweated-Thrd Copper (Cast) 9' 120 1.380 26 0.8 1 Pipe 1k" PVx15 BlazeMa Plastic 220' 150 1.394 26 7.8 1 1" Thrd Other Valve Meter CHART LOSS 26 2.6 4 1" Sweatd 90 Ell Copper (Wrot) 8' 120 1.049 26 2.2 1 1/2" Sweatd 90 Ell Copper (Wrot) 0' 120 0.490 26 0.0 19.5 psi Hydr Ref R1 Required at Source 26 44.6 psi Water Source 80.0 psi static, 20.0 psi residual @ 500 gpm 26 gpm 79.7 psi SAFETY PRESSURE 35.1 psi Available Pressure of 79.7 psi Exceeds Required Pressure of 44.6 psi This is a safety margin of 35.1 psi or 44 % of Supply Maximum Water Velocity is 8.9 fps Shaglani Residence Drawing Date:11/7/2014 11/10/14 9:38 Page 3 FITTING NAME TABLE ABBREV. NAME C Coupling E 90' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90' Flow Thru Tee ✓ Valve LEGEND HYD REF Hydraulic reference. Refer to accompanying flow diagram. _ K FACTOR Flow factor for open head or path where Flow (gpm) = K x -\/P Qa Flow added or subtracted Qt Total flow DIA Actual internal diameter of pipe C Hazen Williams pipe roughness factor Pf/ft Friction loss per foot of pipe PIPE Length of pipe FTNG'S Number of fittings. See table above. TOTAL Total length (PIPE + FTNG'S) Pt Total pressure (psi) at fitting Pe Pressure due to change in elevation where Pe = 0.433 x change in elevation Pf Friction loss (psi) to fitting where Pf = 1 x 4.52 x (Q/C)^1.85 / ID^4.87 Pv Velocity pressure (psi) where Pv = 0.001123 x Q^2/ID^4 Pn Normal pressure (psi), where Pn = Pt - Pv NOTES: - Pressures are balanced to 0.01 psi. Pressures are listed to 0.1 psi. Addition may vary by 0.1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations Shaglani Residence Drawing Date:11/7/2014 11/10/14 9:38 Page .4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K -FACTOR FLOW FLOW DENSITY (FT) (GPM/(PSI^11)) (PSI) (GPM) (GPM) (GPM/SQ.FT) 1 19.00 1S 18.50 2 19.00 2S 18.50 W 10.00 4.30 4.30 9.0 9.1 9.4 9.3 19.5 13.0 13.1 Max velocity of 8.89 occurs in the pipe from W TO 2 13.0 1.00 13.0 1.01 Nodes with "S" indicate a node at the top of a sprig or bottom of drop pendent. The node without an "S" is on the branch. Shaglani Residence Drawing Date:11/7/2014 Tyco Fire Products 11/10/14 9:38 Page 5 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE 1 TO W (PRIMARY PATH) 1S 13.00 1.101 1E 0.50 9.1 9.1 K = 4.30 C=150 3.02 -0.2 0.0 13.00 0.031 3.52 0.1 9.1 Vel = 4.42 1 1.101 C=150 13.00 0.031 10.58 9.0 9.0 EqK = 4.33 0.00 0.0 0.0 10.58 0.3 9.0 Vel = 4.42 2 13.13 1.101 3T 33.66 9.4 9.4 EqK = 4.29 C=150 22.67 3.9 0.0 26.13 0.112 56.33 6.3 9.4 Vel = 8.89 W 26.13 19.5 K = 5.91 13.13 1.101 1T 0.50 9.3 9.3 K = 4.30 2S C=150 7.56 -0.2 0.0 13.13 0.031 8.06 0.3 9.3 Vel = 4.47 2 13.13 9.4 K = 4.29 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Shaglani Residence Drawing Date:11/7/2014 11/10/14 9:38 HYDRAULIC DESIGN INFORMATION SHEET Job Name: Shaglani Residence Location: 2916 S 135th St Tukwila, WA 98168 Drawing Date: 11/7/2014 Contractor: Wolfe Fire Protection, Inc. 17321 Tye St SE #B Monroe, WA 98272 Designer: Jeff Moen Calculated By:SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: VB Reviewing Authorities:City of Tukwila Remote Area Number: 2 Telephone:360-794-7926 Occupancy:Residential SYSTEM DESIGN Code:NFPA 13 D Hazard:RESIDENTIAL System Type:WET Area of Sprinkler Oper. Density (gpm/sq ft) Area per Sprinkler Hose Allowance Inside Hose Allowance Outside sq ftI RES 130.0 sq ftl 0 gpm 0 gpm Sprinkler or Nozzle Make: Globe Model: GL5635 K -Factor: 5.60 Temperature Rating: 155 CALCULATION SUMMARY 2 Flowing Outlets gpm Required: 29.8 psi Required: 37.7 @ Source WATER SUPPLY Water Flow Test Date of Test Static Pressure Residual Pres At a Flow of Elevation 80.0 psi 20.0 psi 500 gpm 0" Pump Data Rated Capacity 0 gpm Rated Pressure 0.0 psi Elevation 0 Make: Model: Location: Source of Information: SYSTEM VOLUME 15 Gallons Notes: 4 m mmm 000 R 0 O ..: O -= E E. U)O0'v� 0C)C)C1C1 -00O) IMMIXi M wr mom anrn 000 0 co N � O. 0 0 0 - 0 0 V' N 0 00 CD v v- r • 0 N ax v, in • w Shaglani Residence Drawing Date:11/7/2014 11/10/14 9:38 HYDRAULIC CALCULATION DETAILS QTY DESCRIPTION HYDRAULIC FLOW LOSS LENGTH C ID gpm psi TOTALS Hydr Ref W Required at Hyd Area 2 30 8.4 psi 3 1-1/4" CPVC 90 Ell CPVC 18' 120 1.380 30 2.1 Elevation Change 13'0" 5.6 1 1'" Grvd Back Flow Valve Ames 200 CHART LOSS 30 4.5 3 1-1/4" Sweated-Thrd Copper (Cast) 9' 120 1.380 30 1.0 1=Pipe 1'4" PVx15 BlazeMa Plastic 220' 150 1.394 30 9.9 1 1" Thrd Other Valve Meter CHART LOSS 30 3.4 4 1" Sweatd 90 Ell Copper (Wrot) 8' 120 1.049 30 2.8 1 1/2" Sweatd 90 Ell Copper (Wrot) 0' 120 0.490 30 0.0 Hydr Ref R1 Required at Source 30 37.7 psi Water Source 80.0 psi static, 20.0 psi residual @ 500 gpm 30 gpm 79.7 psi SAFETY PRESSURE 41.9 psi Available Pressure of 79.7 psi Exceeds Required Pressure of 37.7 psi This is a safety margin of 41.9 psi or 53 % of Supply Maximum Water Velocity is 6.3 fps 1 Shaglani Residence Drawing Date:11/7/2014 11/10/14 9:38 Page 3 FITTING NAME TABLE ABBREV. NAME C Coupling E 90' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90' Flow Thru Tee ✓ Valve LEGEND HYD REF Hydraulic reference. Refer to accompanying flow diagram. _ K FACTOR Flow factor for open head or path where Flow (gpm) = K x -\/P Qa Flow added or subtracted Qt Total flow DIA Actual internal diameter of pipe C Hazen Williams pipe roughness factor Pf/ft Friction loss per foot of pipe PIPE Length of pipe FTNG'S Number of fittings. See table above. TOTAL Total length (PIPE + FTNG'S) Pt Total pressure (psi) at fitting Pe Pressure due to change in elevation where Pe = 0.433 x change in elevation Pf Friction loss (psi) to fitting where Pf = 1 x 4.52 x (Q/C)^1.85 / ID^4.87 Pv Velocity pressure (psi) where Pv = 0.001123 x Q^2/ID^4 Pn Normal pressure (psi), where Pn = Pt - Pv NOTES: - Pressures are balanced to 0.01 psi. Pressures are listed to 0.1 psi. Addition may vary by 0.1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations Shaglani Residence Drawing Date:11/7/2014 11/10/14 9:38 Page 4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K -FACTOR FLOW FLOW DENSITY (FT) (GPM/(PSI^&1)) (PSI) (GPM) (GPM) (GPM/SQ.FT) 3 10.00 3S 9.50 4 10.00 4S 9.50 10 10.00 W 10.00 5.60 5.60 6.9 7.0 7.1 7.2 7.6 8.4 14.8 15.0 Max velocity of 6.33 occurs in the pipe from 10 TO W 14.8 0.11 14.8 0.12 Nodes with "S" indicate a node at the top of a sprig or bottom of drop pendent. The node without an "S" is on the branch. Shaglani Residence Drawing Date:11/7/2014 Tyco Fire Products 11/10/14 9:38 Page 5 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE 3 TO W (PRIMARY PATH) 14.82 1.101 1E 0.50 7.0 7.0 K = 5.60 3S C=150 3.02 -0.2 0.0 14.82 0.039 3.52 0.1 7.0 Vel = 5.04 3 1.101 1T 8.63 6.9 6.9 EqK = 5.63 C=150 7.56 0.0 0.0 14.82 0.039 16.19 0.6 6.9 Vel = 5.04 15.02 1.394 18.82 7.6 7.6 10 C=150 0.00 0.0 0.0 See PATH 2 29.84 0.045 18.82 0.9 7.6 Vel = 6.33 W 29.84 8.4 K = 10.29 PATH 2 FROM HYDRAULIC REFERENCE 4 TO 10 15.02 1.101 1E 0.50 7.2 7.2 K = 5.60 4S C=150 3.02 -0.2 0.0 15.02 0.040 3.52 0.1 7.2 Vel = 5.11 4 1.101 1T 3.25 7.1 7.1 EqK = 5.63 C=150 7.56 0.0 0.0 15.02 0.040 10.81 0.4 7.1 Vel = 5.11 10 15.02 7.6 K = 5.47 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) PEAK DINING 0 0 J (n LIVING KITCHEN NOOK INSTALLATION GUIDELINES NFPA 13D ALLOWS SPRINKLERS TO BE OMITTED IN: 1) BATHROOMS NOT EXCEEDING 55 sq. ft. 2) CLOSETS NOT EXCEEDING 24 sq. ft. WHERE THE LESSER DIMENSION DOES NOT EXCEED 3'-0 3) ATTICS, CRAWLSPACES, AND OTHER CONCEALED AREAS NOT INTENDED AS LIVING SPACE 4) EXTERIOR DECKS OR PORCHES SPACING OF SPRINKLERS IS 16' X 16'. MAXIMUM DISTANCE FROM A WALL IS 8'. MINIMUM DISTANCE BETWEEN HEADS TO PREVENT COLD SOLDERING IS 8'. ALL PIPING TO BE CPVC AND COPPER ALL CEILINGS ARE FLAT, SMOOTH, UNOBSTRUCTED, AND NONCOMBUSTIBLE UNLESS NOTED OTHERWISE. C O LST. FAMILY 9PNTO ABOVE ENTRY 111P*— PER TENTATIVE INTERIM AMENDEMENT NO. 1028R TO 2010 NFPA 13D, SLOPED CEILINGS UP TO 8:12 WITH BEAMS UP TO 14" DEEP AND MAXIMUM CEILING HEIGHTS OF 24 FEET ARE PERMITTED TO HAVE A 2 -HEAD DESIGN AREA BASED ON THE SAME FLOWS REQUIRED FOR FLAT CEILINGS. THE DEMAND FOR THE 2 REMOTE HEADS IN THE LIVING ROOM IS THEREFORE THE SAME AS REMOTE AREA 1 (THE MASTER BEDROOM) AND THAT AREA HAS BEEN CALCULATED AS IT IS MORE REMOTE FROM THE RISER BOTH IN TERMS OF FRICTION LOSS AND ELEVATION. RI SI- R 3PTAIL 1-1/4" TO SPRINKLER SYSTEM FLOWSWITCH TO BE WRED TO EXTERIOR ALARM BELL BY OWNER'S ELECTRICIAN 1-1/4" AMES 2000B DOUBLE CHECK VALVE ASSEMBLY 1-1/4" RESIDENTIAL RISER WITH PRESSURE GAUGE, FLOWSWITCH, AND INSPECTOR'S TEST & DRAIN. SPRINKLER FITTER'S RESPONSIBILTY i TO DOMESTIC PLUMBER'S RESPONSIBILTY Ch g 1-1/4 I.P.S. UNDERGROUND PIPING FROM 1" METER CLST. PWDR. \ 4 O STUDY 1" CPVC / UP 9'-0" CLST. , n Aw SYSTEM RISER (SEE DETAIL) REMOTE AREA 2 2 DRY PENDENT SPRINKLERS CALCULATED AT 0.05 GPM PER HEAD FOR 130 SQFT SPACING. a 0 130.0 2 VA \ GARAGE �10 130.0 2 \ f- LOOK ��A\ SCALE: 1 /4"=1'—O" M. BATH PWDR. OPEN TO BELOW REMOTE AREA 1 2 RESIDENTIAL SPRINKLERS FLOWING AT 13 GPM PER HEAD FOR 16' X 16' SPACING. 6.5 GALLONS REQUIRED PER BUCKET FOR A 30 -SECOND TEST. MOST HYDRAULICALLY REMOTE AREA. BUCKET TEST HERE. LNDRY. CLST. BED 4 BONUS CLST. BED 3 LOOK -'LA\ SCALE: 1 /4"=1'—O" .D OJECT \OYES SITE ADDRESS: PARCEL #: PROPERTY OWNER: JURISDICTION: SCOPE OF WORK: WATER PURVEYOR: WATER AVAILABILITY: 2916 S 135TH ST TUKWILA, WA 98168 7346600128 SARANJEET SHAGLANI 14208 4TH AVE S BURIEN, WA 98168 6.5.3 A warning sign, with minimum 'A inch letters, shall be affixed adjacent to the main shutoff valve and shall state the following: WARNING: The water system for this home supplies fire sprinklers that require certain flows and pressures to fight a fire. Devices that restrict the flow or decrease the pressure or automatically shut off the water to the fire sprinkler system, such as water softeners, filtration systems, and automatic shut- off valves, shall not be added to this system without a review of the fire sprinkler system by a fire protection specialist. Do not remove this sign. CITY OF TUKWILA DESIGN AND INSTALLATION OF NEW AUTOMATIC FIRE SPRINKLER SYSTEM IN NEW SINGLE FAMILY RESIDENCE. KING COUNTY WATER DISTRICT 125 STATIC PRESSURE IS 80 TO 90 PSI PER KCWD 125. PRESSURE TO BE VERIFIED DURING INSTALLATION. DESIG\ MITES SYSTEM IS DESIGNED IN ACCORDANCE WITH 2010 NFPA 13D.. HYDRAULIC CALCULATIONS HAVE BEEN PERFORMED AND SUBMITTED FOR TWO REMOTE SPRINKLERS OPERATING PER NFPA 13D. MINIMUM FLOWS AND PRESSURES REQUIRED BY THE SPRINKLER LISTINGS HAVE BEEN PROVIDED TO THE REMOTE! SPRINKLERS WITH THE GIVEN SIZING OF PIPE, FITTINGS AND VALVES. DRY PENDENT SPRINKLERS ON CPVC PIPING WILL PROTECT GARAGE. GARAGE PIPING MUST BE INSULATED BELOW AND NOT ABOVE TO PREVENT FROM FREEZING. A 200 PSI HYDROSTATIC PRESSURE TEST OF ABOVEGROUND SPRINKLER PIPE WILL BE PERFORMED BY WOLFE FIRE PROTECTION, INC., WITNESSED BY TUKWILA FIRE INSPECTOR, AND DOCUMENTED IN CONTRACTOR'S MATERIALS AND TEST CERTIFICATE FOR ABOVEGROUND PIPING A COVER INSPECTION IS REQUIRED PRION TO CONCEALMENT OF SPRINKLER PIPING ALL CPVC PIPING TO BE BRACED AND SUPPORTED USING UL LISTED CPVC PIPING HANGERS AS REQUIRED BY THE LISTING OF CPVC PIPE SI TI- L�A\ SCALE: 1 /32"= 1'=—O" WATER MAIN D O w U CEP C7 Without Comments As Noted in Red Per The Attached Letter plans have been reviewed by The Tukwila Fire :vention Bureau for conformance with current City =ndards. Acceptance is subject to errors and missions which do not authorize violations of adopted ;-,ndards and ordinances. The responsibility for the <<dequacy of design ret::: totally with the designer. Additions, deletions or revisions to these drawings after Is date will void this acceptance and will require a resubmittal of revlsed drawings for subsequent approve I. Final acceptance Is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: /1-1?- By, 1-1/4" IRON PIPE SIZE UNDERGROUND LINE TO HOUSE (COMBINED FOR FIRE/DOMESTIC) WKWILA FIRE DEPARTMENT ')lease call 206-575-4407 and gi'va this Fire Permit No. /14-S-).(ey ind exact address for shut Jown or restoration approval. WATER METER S 135TH ST SYM CNT POSITION FINISH TEMP K NPT SIN MFG. MODEL# Q 27 PEND WHITE 165 4.30 1/2" RA0612 RELIABLE RFC ig 4 PEND CHROME 155 5.60 1" GL5641 GLOBE GL PAID NOV :10 2014 TUKWILA FIRE m el -0 ALL z cc w a 0 z z 0 a) w 0 z 4 0 cn 0 B Residence Cn CD • 4-1 Q) O Ff CV N ci c0 Cid a5 0 CONTRACTOR #: WOLFEFP906DD R liRlrofd�lf 44 CEeTWICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Jeffrey R. Moen 8131 -0209 -CF Wolfe Fire Protection, Inc: WOLFEFP906DD illi �mmmmmmmm mmmmmm 1