Loading...
HomeMy WebLinkAboutPP - 3720 S 130TH ST - RIVERTON ADDITION - PERMITS AND PLANS3720 S 130TH ST ASSOCIATED PERMITS 95-5-156 B95-0187 i'Tj+'i''j�7:%"}f'.'T'lYapf'iff^�y�Z'y°'n`L'i*%�te1.'J*;.5i,'XF.^.irl+'Y+ve'"�„yrY City of Tukwila Fire Department TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name RiVet/ [i o�`1,%S -1 Address T>S / 30_14"/ Retain current inspection schedule Needs shift inspection MAY 2 3 1996 John W Rants, Mayor Thomas P. Keefe, Fire Chief Permit No. CD/6S% Suite # C Approved without correction notice Approved with correction notice/issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre --Fire: Permits: 0- _ P Authorized Signature / Date FINALAPP.FRM T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 DESIGN CALCULATIONS (NFPA 13th) PI1E SIDENTIAL FIRE SPRINKLER SYSTEM Activity 1 Project Names New Residence - Urban Homes Inc Project Location: 37XX 130th St, Tukwila, WA - Available Water Supply: 28 g.p.m. at: Max Sprinkler Spacing: 8 ft. X 90 Lot #17 Sheet Not 1 'Of 1 Dates June 16, 1995 Bys J A Lynch Floor Level t Two Elev. of 8pkrat R' p.s.i. Locations Main at street 16 ft. Sprinkler I.DiCentral GBR Conc Pend & SW ONE -SPRINKLER DESIGN! Min. Flows 19 gift; Min. press: 19.5psi TWO -SPRINKLER DESIGN! Min. Flow! 28 gpm; Min. press: 10.6 psi Type of Piping: x crvc rvc Steel. (Sch. 40) Copper K, L, M (Circle one) CALCULATIONS 2 Sprinkler nowt System demand - 28 gpm CALCULATIONS 1 Sprinkler flow: System demand = 19 gpm PIPING (1 spkr flow) TOTAL UNIT_ TOTALDIA. LENGTH X FR LOSS FR LOSS Service (PVC) 1" 80' System (CPVC) 1" 50' .0597 4.78 „ Plus 151 FITTINGS 6 VALVES (1 spkr flow) 2.99 1.17 DTA. & Unit TOTAT. UNIT TOTAT. TYPE QTY. EQ.LEN.EQ.LEN.X FR.T,OSS FR.T.OSS 1"90°L 3 7' 21' 1"T Rn 6 1' 6' 1"T Br 5 5' 25' 1"Fl Sw 1 4' 4' 1" Febco Model 805Y BFP .0597 „ „ METER FRICTION TOSS (Size=1" ) SPKR PRESSURE REQUIRED ELEVATION BEAD LOSS (26 ft X 0.434) TOTAL SYSTEM PRESSURE DEMAND TOTAL SUPPLY PRESSURE AVAILABLE 1.25 :36 1.49 .24 4.00 4.00 19.50 11.28 . 51.06 PIPING (2 spkr. flow 2228 gpm) ' TOTALUNIT TOTAT, DIA LENGTH X• FR LOSS' . FR LOSS Service (PVC) System (CPVC) 1" 50' 1" 80' .1224 9.79 6.12 rlun 1S1 2.39 PITTINGS. & .VALVES ,(2-spkr. flow -28 gpm) UNIT TOTAL UNIT TOTAT. TYPE QTYX RQ LEN , EQ LEN FR 1I JJ®r P1l LOSS nrA & 1"90°L 3 7' 21' .1224 1"T Rn 6 1"T Br 5 1' 6' 5' 25' 1"Fl Sw 1 4 4 1" Febco Model 805Y BFP n „ METER PRTCTTON LOSS (sine- 1" ) srRTNRLRR PRESSURE. REQUIRED 2.57 .73 3.06 .49 4.00 4.00 10.60 P.T.RVATTON HEAD TOSS ( 26 ft X .434) 11 28 .TOTAL. SYSTEM PRESSURE DEMAND TOTAL SUPPLY PRESSURE AVAILABLE 55.03 0.00 NORTHWEST RESIDENTIAT, FIRE SPRINKLER INC 1625 Ethridge Ave. NE Olympia, WA 98506 (206)754-6475 FAX 1206)459-3561 Contractor's Reg. INWRESFS0858A Fue S • n°k1e. oF 9.loACeIIrtifica1C : : nJerryq,Lynch ►•�7-`ay j 163216 00 00 D� 0 T/, /39 /07- c3.4/"Riser \. / _scale: / _ .20`-O v eV 0 L -i.112.0? O 4" i �*Ath: .itst.-fS 1he1r UPPER Fl t7 /I PLAh1 E jcgie'0` F ON w ;,e f L 0 \jUf 7117 2 dmoi. 1.0 W.6.1? ,c1.09/2 P1A Sc c'/e : Test & Dra n Valve Main Drain f- To Sprinkler System . Gauge Q ,' F1ow Switch Ihi>< <1><1--1 C UFP RISER DETAIL No Scale TUKWILA FIRE DEPARTMENT Please call: 575.4407 and give this job No. and exact address for shut, down or restoration approval. r-• To Domestic / From Supply Control Valve ACCEPTED ITHOUT COMMENTS. AS NOTED IN RED PER THE ATTACHED LETTER The drawings affixed hereto have been - reviewed and accepted by the City of Tukwila Fire De,}t.:A 1 iitions, deletions or revisions t)''a9 ; : rings after this date will ,i i • r ::gee and will require a re ' ,i`' I of revised drawings. Final i..;• :•1:) ject to field- inspe ' rewesentative of this dep:.i i:: uni DATE:,BY: Sa-- CITY OF TUKWILA 575-440/ v P/2 mss- 9e sperm NOTE: ALL SPRINKLER PIPING TO 1' CPVC FLOW SWITCH TO BE POTTER 120V ALARM BELL TO BE POTTER 6', 120V BFP TO BE FEBCO MODEL 805Y DOUBLE CHECK SPRINKLERS TO BE CENTRAL GER CONCEALED PENDENT & SW MAIN FLOOR --------------- 7 En UPPER FLOOR / f FA BASEMEMENP------- M/4 EA TOTAL /B EA z 51 Lr) 00 w I74 z 0 U DATE: „,h6 9S