Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 3231 S 133RD ST - DARYL TAPIO - PERMITS AND PLANS
3231 S 133RD ST ASSOCIATED PERMITS D97-0039 City of Tukwila FILE • John W. Rants, Mayor Fire Department Thomas P. Keefe, Flee Chief May 7, 1997 Fire Department Review Control #D97-0039 Re: T a p i o, Daryl - 3231 South 133rd Street Dear Sir:. The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Your fire department access road must be designed to meet or exceed Tukwila Public Works standards. Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd Headeuarters Station! 444 Andover Park Eat • Tukwila Washington 98188 • Paan& 1206) 57544404 • Par 1206) 575,4434 FILE City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fin? Chief February 27, 1997 Fire Department Review Control #D97-0039 (511) Re: Daryl Tapio - 3231 South 133rd Street, Lot B Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Every building shall be accessible to Fire Department apparatus by way of access roadways with all-weather driving surface of not less than 20' wide and 13'6" vertical clearance. Access roads in excess of 150' shall be provided with an approved turn -around area. Access shall be within 150' of all portions of the buildings. (UFC 902.2.2.1, UFC 902.2.1) 2. For short plat development (four single family homes or less), hydrants shall be placed so that a hydrant is within 250 feet of a building. Distance from a hydrant to a building is measured along the path of vehicular travel. The hydrant must flow a minimum of 1000 GPM at 20 PSI residual pressure. 3. Fire hydrants shall conform to American Water Works Association specifications C-502-54; it shall be compression type, equipped with two 2 1/2" N.S.T. hose ports and one 5" Storz pumper discharge port, and shall have a 1 1/4" Pentagon open -lift operating nut. 4. All required hydrants and surface access roads shall be installed and made serviceable prior to and during the time of construction. (UFC 901.3) 5. In lieu of a fire hydrant, an approved residential fire sprinkler system may be installed when vehicular Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206,1 575- 4439 City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chtef Page number 2 travel distance from the nearest hydrant exceeds 250 feet. Acceptance of residential fire sprinkler systems shall include field verification of GPM and residual pressures meeting or exceeding the listing for the sprinkler type. 6. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 901.4.4) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd Headquarters Station: 444 Andover Park Fast a Tubvi7a,, f'asJ ington 98188 • Phone: (206) 575-4404 • Fax. (206) 575-4439 City of Tukwila Fire Department r FF SEP 1 0 1997 John W. Rants, Mayor TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Namb/MVLI"O/D e Tel/ X2-3/ /33 - Address ..� Thomas P. Keefe, Fire Chief Permit No. /)7 -©O3 / Suite # Retain current inspection schedule Needs shift inspection i< Approved without correction notice. Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Signature FINALAPP.FRM T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439