Loading...
HomeMy WebLinkAboutPP - 4027 S 126TH ST - TUKWILA RESIDENCE - PERMITS AND PLANS4027 S 126TH ST ASSOCIATED PERMITS 19-5-089 D18-0163 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Site Address: 70,2/ S /2 Tenant Name: C4.2 At y FAA Property Owner's Name: Cali 4g y Mailing Address: x/0.21 S 42C f& **PLEASE PRINT** King Co. Assessor's Tax No.: Suite Number: Floor: New Tenant?/�- Yes ❑ - No CONTACT PERSON -if there are questions about the submittal. Name h. 01A » raJ ? Company Name: k+ vc SD(ir(toPtS t.,JJ c, City State Zip Day Telephone: Mailing Address: I710 AUbUV IN. (A..)41. i,j ikcioui . W a ` ID ("X7 Z. watt City State Zip E-mail Address: trot& 1f .tM 6) kok att. cow, Fax Number: Contractor's City of Tukwila NICET III number:��il 5)123—�isis t ^ ( Business License number: Total number of new/relocated devices or sprinkler heads: SO Valuation of Project (contractor's bid price): $ 5/00 Scope of Work (please provide detailed information): t .96.4) kat) airy fl 5174.41,14- PERMIT 174. 1,14 - PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Plan Permit App.doc PAID APR 2 4 2019 rU K Y I LDa!'I elephone: Date: I j1q —./? 8/22/14 TFD FP Form 8 3 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit D�8 -o►c03 l9-s-o8`i PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project�G� // ( �� Type of Ins /n: Address: Suite #: Y02,7 Hood & Duct: Contact Person: S, /24 Special Instructions: Permits: Phone No.: proved per applicable codes. COMMENTS: Corrections required prior to approval. tars tee rr} Needs Shift Inspecti : 11 Sprinklers: 70ZFire Alarm: 6" Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector( n/113 Date: /0/Z3//ff Hrs.: !. a $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspecton. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Z INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 1116- otu /9-S - 0•549 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: Type of Ins ection: lki'GkyoJ 7..c2 Address:--\--),, Suite #: yDZ S, 1 LAP Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: DV o r QA : 1) No Foa,,r,-k.a 4-0 bat s4vrc.cf Iv 4.6kIre - 2) 0-0 .-rDed.vbc- iv 6 ottecte ?..)le-tk 1 1,3% i- ,,,,c,Altr-, ItNs elksrf `70 CO ( 1"a r 1 v iti Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspectors ,i43 Date: /0/ts-A9 Hrs.: /, 0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from t e City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: .ro Z kl #y,rk Si - City: S'eics.,Tt.t_ Word/Inspection Record Form.Doc State: Wf Zip: 98i0‘ 6/11/10 T.F.D. Form F.P. 113 i INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:J - f,� Sprinklers: Fire Alarm: Type of Inspection • iterV Address:// Suite #: �U 5 A-- (7i6 Contact Person: Special Instructions: Phone No.: .4> pproved per applicable codes. Corrections required prior to approval. COMMENTS: (?(-1 P‘re 141P P-Cnie C-e\f‘e lc_ cat' G.Tect 5 42A-cep7L-- v -,c 5 �zt c ✓s — ACJ f'lE*3 -PQ � Iii� r s r�- a C,(444-<-4- Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Typ . Inspector: ,!k--74/7 b 4 Date: //-/ Hrs.: l V $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 19-5-(-' Hydraulic Calculations Sheet 1 for Project Name: Tukwila Residence Location: 4027 So 126th Tukwila, WA Design: Occupancy classification: Density: Area of application: Coverage per sprinkler: Type of sprinklers calculated: No. of sprinklers calculated: Total water required: Including hose streams Type of System: Date 04/23/19 Job: TUKWILAR NFPA 13D 0.05 gpm/sq.ft. 512 square feet 16' x 16' max. Reliable Conceald Res.K=4.9 2 heads 38.52 psi @ 26.1 gpm @ Supply 80.00 psi available @ 26.1 gpm Below curve by 41.48 psi Wet Water Supply Information: 80.00 psi Static Name of Contractor: 1st Fire Solutions Phone Number: Authority Having Jurisdiction: NFPA-13 Program: 'HydroCalc' by Micro Space Systems www.MicroSpaceSystems.com ■ WASHINGTON STATE I CERTIFICATE Of COMPETENCY is FIRE PROTECTION SPRINKLER SYSTEMS a Rick Berger 3928-0691•CG Level 3 1st Fire Solutions, L.L.C. 1 'FIFO !1 F q 4 111.1111111•111 00000MNIONINBOalle 0000 Flow Test Summary Sheet N1.85 Z 3aa4S • co (ISd) amssaJd M 0 O O N 1!) O O • Static = 80 psi. Tukwila Residence Sheet 3 1st Fire Solutions Description of Fitting abbreviations Code Description PT Plastic Tee PE Plastic 90 degree Elbow BKF Backflow preventor MTR Meter Loss Description of Other abbreviations Code Description AO Arm -over BL Branch Line CM Cross Main PT Total pressure PE Pressure loss due to elevation changes PF Pressure loss due to friction ".5 Raised to the power of .5 (Square Root) L Actual pipe length F Fitting equivalent pipe length T Total pipe length TUKWILAR 04/23/19 9:54am Sheet 4 1st Fire Solutions Sprinkler Systems Hydraulic Flow Calculations Tukwila Residence 4027 So 126th Tukwila, WA Raw data previous to any calculations No. Code Diam Length Kfacl Kfac2 Press Elev Hose HW Vel Fittings 1 AO1 1.109 5.50 4.9 7.000 0.000 0.0 150 32 1PT 2 BL1 1.109 29.00 4.9 7.000 0.000 0.0 150 32 1PT 3 BL2 1.109 20.70 AO1 0.000 0.000 0.0 150 32 1PT 4 CM1 1.109 7.00 BL1 0.000 0.000 0.0 150 32 1PT 5 CM2 1.109 9.00 BL2 0.000 0.000 0.0 150 32 1PT 6 BU1 1.109 10.00 CM1 CM2 0.000 0.000 0.0 150 32 1PE 7 BUl 1.109 8.20 0.000 0.000 0.0 150 32 1PT 8 BU1 1.109 6.00 0.000 0.000 0.0 150 32 1PE 9 RI1 1.109 10.00 BU1 -7 0.000 20.000 0.0 150 32 1BKF,1PE 10 UG1 1.554 35.00 RI1 -7 0.000 0.000 0.0 150 32 1MTR,1PE TUKWILAR 04/23/19 9:54am Sheet 5 1st Fire Solutions Sprinkler Systems Hydraulic Flow Calculations Tukwila Residence 402'/ So 126th Tukwila, WA Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Arm -over 1 C = 150 L 5.5 PT. 7.00 1 13.0=4.90(7.00)^.5 F 5.0 PE 0.00 1 13.0 1.109 1PT T 10.5 0.02945 PF 0.31 4.3 PT 7.31 3 B1 Jct K -factor for arm -over 1 = 13.0/(7.31)^.5 = 4.81 TUKWILAR 04/23/19 9:54am Sheet 6 1st Fire Solutions Sprinkler Systems Hydraulic Flow Calculations Tukwila Residence 4027 So 126th Tukwila, WA Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Branchline No. 1 C = 150 L 29.0 PT 7.00 2 End head 13.0=4.90(7.00)^.5 F 5.0 PE 0.00 2 13.0 1.109 1PT T 34.0 0.02945 PF 1.00 4.3 PT 8.00 4 Cross main Jct K -factor for branchline no. 1 = 13.0/(8.00)^.5 = 4.60 Branchline No. 2 C = 150 L 20.7 PT 7.31 3 A01 13.0=4.81(7.31)^.5 F 5.0 PE 0.00 3 13.0 1.109 1PT T 25.7 0.02961 PF 0.76 4.3 PT 8.07 5 Cross main Jct K -factor for branchline no. 2 = 13.0/(8.07)^.5 = 4.58 TUKWILAR 04/23/19 9:54am Sheet 7 1st Fire Solutions Sprinkler Systems Hydraulic Flow Calculations Tukwila Residence 4027 So 126th Tukwila, WA Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Cross main 1 C = 150 L 7.0 PT 8.00 4 BL1 13.0=4.60(8.00)^.5 F 5.0 PE 0.00 4 13.0 1.109 1PT T 12.0 0.02960 PF 0.36 4.3 PT 8.36 6 Bulk Jct K -factor for Cross main 1 = 13.0/(8.36)^.5 = 4.50 Cross main 2 C = 150 L 9.0 PT 8.07 5 BL2 13.0=4.58(8.07)^.5 F 5.0 PE 0.00 5 13.0 1.109 1PT T 14.0 0.02960 PF 0.41 4.3 PT 8.48 6 Bulk Jct K --factor for Cross main 2 = 13.0/(8.48)^.5 = 4.46 TUKWILAR 04/23/19 9:54am Sheet 8 1st Fire Solutions Sprinkler Systems Hydraulic Flow Calculations Tukwila Residence 4027 So 126th Tukwila, WA Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Bulk Notes C = 150 K=8.96=4.50+4.46 L 10.0 PT 8.48 6 CM 1 + CM 2 26.1=8.96(8.48)^.5 F 7.0 PE 0.00 6 26.1 1.109 1PE T 17.0 0.10743 PF 1.83 8.7 L 8.2 PT 10.31 7 F 5.0 PE 0.00 7 26.1 1.109 1PT T 13.2 0.10743 PF 1.42 8.7 L 6.0 PT 11.72 8 F 7.0 PE 0.00 8 26.1 1.109 1PE T 13.0 0.10743 PF 1.40 8.7 PT 13.12 9 K -factor for Bulk = 26.1/(13.12)^.5 = 7.21 Riser C = 150 L 10.0 PT 13.12 9 Top of Riser F 7.0 PE 8.66 (EL= 20.0 ft) 9 26.1 1.109 1BKF 1PE T 17.0 0.10748 PF 8.83 8.7 1BKF = 7.00# PT 30.61 10 B.O.R. K -factor for Riser = 26.1/(30.61)^.5 = 4.72 Under ground L 35.0 PT 30.61 10 F 9.0 PE 0.00 10 26.1 1.554 1MTR 1PE T 44.0 0.02079 PF 7.91 PT 38.52 11 Supply pressure available with 26.1 gpm flowing is 80.00 psi, C = 150 B.O.R. 4.4 1MTR = 7.00# Supply Jct thus system requirement is 41.48 psi below supply curve. (51.8%) TUKWILAR 04/23/19 9:54am Sheet 9 Supply Analysis Node at Static Residual Available Total Required Source Pressure Pressure Flow Pressure Demand Pressure 11 80.00 0.00 0.0 80.00 26.1 38.52 Node Analysis Elevation Node Type Pressure Discharge Node (ft) K -Value Source (psi) (glom) Notes 1 20.00 Orif= 4.90 2 20.00 Orif= 4.90 3 20.00 4 20.00 5 20.00 6 20.00 7 20.00 8 20.00 9 20.00 10 0.00 11 0.00 Supply 7.00 13.0 7.00 13.0 7.31 - 8.00 8.07 8.48 10.31 11.72 13.12 30.61 38.52 TUKWILAR 04/23/19 9:54am Sheet 10 ' Pipe Information Nodel Elevl Kfactor Qadd Nominal Fittings L (ft) Cfac Total Pt Pipe (ft) Hose ID F (ft) Vel Elev Pe Node2 Elev2 Qtot Actual Length T (ft) Psi/Ft Fric Pf Notes 1 20.00 4.90 1 3 20.00 13.0 1" 1PT 13.0 1.109 L 5.5 150 Pt 7.00 F 5.0 4.3 Pe 0.00 5.0 T 10.5 0.0295 Pf 0.31 A01:K=4.81 2 2 20.00 4.90 13.0 1" 1PT 4 20.00 13.0 1.109 L 29.0 150 Pt 7.00 F 5.0 4.3 Pe 0.00 5.0 T 34.0 0.0295 Pf 1.00 BL1:K=4.60 3 20.00 4.81 [13.0] 1" 1PT L 20.7 150 Pt 7.31 A01 3 F 5.0 4.3 Pe 0.00 5 20.00 13.0 1.109 5.0 T 25.7 0.0296 Pf 0.76 BL2:K=4.58 4 20.00 4.60 [13.0] 1" 1PT L 7.0 150 Pt 8.00 BL1 4 F 5.0 4.3 Pe 0.00 6 20.00 13.0 1.109 5.0 T 12.0 0.0296 Pf 0.36 5 20.00 4.58 [13.0] 1" 1PT L 9.0 150 Pt 8.07 BL2 5 F 5.0 4.3 Pe 0.00 6 20.00 13.0 1.109 5.0 T 14.0 0.0296 Pf 0.41 6 6 20.00 7 20.00 1" 1PE L 10.0 150 Pt 8.48 CM 1 + CM 2 F 7.0 8.7 Pe 0.00 26.1 1.109 7.0 T 17.0 0.1074 Pf 1.83 7 7 20.00 8 20.00 1" 1PT L 8.2 150 Pt 10.31 F 5.0 8.7 Pe 0.00 26.1 1.109 5.0 T 13.2 0.1074 Pf 1.42 8 8 20.00 9 20.00 1" 1PE L 6.0 150 Pt 11.72 F 7.0 8.7 Pe 0.00 26.1 1.109 7.0 T 13.0 0.1074 Pf 1.40 9 9 20.00 10 0.00 1" 1BKF 1PE L 10.0 150 Pt 13.12 Top of Riser F 7.0 8.7 Pe 8.66 1BKF = 7.00# 26.1 1.109 7.0 T 17.0 0.1075 Pf 8.83 10 0.00 1 1/2" 1MTR 1PE L 35.0 150 Pt 30.61 10 F 9.0 4.4 Pe 0.00 1MTR = 7.00# 11 0.00 26.1 1.554 9.0 T 44.0 0.0208 Pf 7.91 Supply REVISIONS BY MAXIMUM ALLOWABLE DISTANCE OF RESIDENTIAL HEADS IN GWB CEILING AREAS DEFLECTOR ABOVE SURFACE MOUNTED LIGHT FIXTURES GWB CEILING "A' DISTANCE FROM SPRINKLER TO SIDE OF FIXTURE Less than 1 ft 0" One ft to -less-than 1 ft 6 in. 0 1 ft 6 in. to less than 2 ft 1" 2 ft to less than 2 ft 6 in. 1" 2ft6in.tolessthan3ft 1" 3 ft to less than 3 ft 6 in, 3" 3 ft 6 in. to less than 4 ft 3" 4fttoless than 4ft6in. 5" 4 ft 6 in. to less than 5ft 7" 5 ft to less than 5ft 6 in 7" S ft 6 in. to Tess than 6ft 7" 6 ft to less than 6ft 6 in 9" 6ft6intoless than 7ft 11" 7 ft and greater 14" "B" MAXIMUM ALLOWABLE DISTANCE OF DEFLECTOR ABOVE. BOTTOM OF FIXTURE VIP 1) System Type: Wet 2) All material shall be new and U,L, listed or RM. approved 3) Fire sprinkler system to be installed braced and tested in accordance with N;FP.A. #13 4) in localities subject to freezing conditions, it is the owners responsibility to provide heat throughout the wet pipe sprinkler system areas and in enclosures 'for valves controlling water supplies to sprinkler systems 5) Pipe and fittings to be CPVC "SLAZEMASTER" 6) Hangers to be TOLCO #22 or #23 (or equal) 7) Hangers spacing; Maximum distance between hangers for CPVC pipe 3/4" 1" 1 1/4" 1 1/2" 2" 6'6" 6'0" 6'6" 7'O" 8'O" 8) Locate a hanger within 6" of each sprinkler head 9) Sprinkler system designed per N.F.P.A: 13D 10) 16' x 16' Maximum Head Spacing 3'-0" Dead end piping max. E ED 4TT1C SPACE CEILING! :JSULATI IN--_ (BYOTHERS) MINIMUM 6 MIN. TRUSS CHORD OR JOIST SPRINKLER PIPE /2" GYPRCCK -- (BY OTHERS) APOUR BARRIER (BY OTHERS) ED Without Comments As Noted in Red ❑ Per The Attached Letter CPVC PIPE STRAP HANGER APPLICATION RESTRAINER APPLICATION HANGER CLIP 6"'MIN. CEILING INSULATION (BY OTHERS) T TRUSS CORD These plans have been reviewed by The Tukwila Fire evention Bureau for conformance with current City ;tenaards. Acceptance is subject to en -ors and _'nlsslons which do not authorize violations of adopted andards and ordinances. The responsibility for the adequacy of design rests Cu lly with the designer. Additions, deletions or revisions to these drawings after I this date will void thL3 acceptance and will require a resubmittal of revised drawings for subsequent approve' Final acceptance is s. bject: to If eid test and Inspection by The Tukwila Fire P 'v''ei'l Iva; Bureau. Date: 5. By. Jr i I CPVC PIPE- HEX HEAD SELF TAPPING SCREW CPVC PIPE DOUBLE FASTENER SINGLE FASTENER CPVC PIPE STRAP CPVC PIPE STRAP 1/2" GYPROCK VAPOUR BARRIER (BY OTHERS) Rau r, ri11YR 9i7YureMMMMMM we" i lk.TtP%tCATR-Olt C®MNl&TNNCY I9 a $I1:.111CTION IIPRIINKLER 411Y4111111, • I •C0 L 13` Drawn e Sheet Of / Sheets Ammommilik 30 X 42 PRINTED ON NO. 1000H CLEARPRINT®