HomeMy WebLinkAboutPP - 3208 S 130TH ST - NORTHWEST DEVELOPMENT - PERMITS AND PLANS3208 5130TH ST ASSOCIATED PERMITS 96-S-275 B96-0008 B95-0188 City of Tukwila John W. Rang Mayor Fire Department Fire Department Review Control #B96-0008 (510) Thomas P. Keefe, FireChief January 16, 1996 Re: Northwest Development - 3208 South 130th Street Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. For short plat development (four single family homes or less), hydrants shall be placed so that a hydrant is within 250 feet of a building. Distance from a hydrant to a building is measured along the path of vehicular travel. For all commercial, multifamily and single family subdivisions, hydrants shall be placed so that a hydrant is within 150 feet of a building and so that no point of a building (around it's perimeter) is greater than 300 feet from a hydrant. Distance from a hydrant to a building is measured along the path of vehicular travel. Fire hydrants shall conform to American Water Works Association specifications C-502-54; it shall be compression type, equipped with two 2 1/2" N.S.T. hose ports and one 5" Storz pumper discharge port, and shall have a 1 1/4" Pentagon open -lift operating nut. All required hydrants and surface access roads shall be installed and made serviceable prior to and during the time of construction. (UFC 901.3) 2. In lieu of a fire hydrant, an approved residential fire sprinkler system may be installed when vehicular travel distance from the nearest hydrant exceeds 250 feet. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206) 575.4404 • Far (206) 575-44.39 City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fine Chief Page number 2 Acceptance of residential fire sprinkler systems shall include field verification of GPM and residual pressures meeting or exceeding the listing for the sprinkler type. 3. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 901.4.4) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Far (206) 575-4439 ULU 2 4 1996 Ct % of TukwilaJohn W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name 6 c\\*\w t S) -(v -AA o ,7 Nvz Address 3 702) S l O Permit No. Z t(o — 0002> \-4\ Retain current inspection schedule Needs shift inspection Suite # Approved without correction notice Approved with correction notice issued Sprinklers: S Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Signature FINALAPP.FRM 5 I 2— \c,q)c, Date T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 City of Tukwila Fire Department APR 2 2 1996 John W. Rants, Mayor TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name / V1JI4 01 Thomas P. Keefe, Fire Chief Permit No. R9,..c-o/8. $ Address 30- /_10 ru7 S Suite # 3zOg Retain current inspection schedule Needs shift inspection 44* Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: H,Un Authorized Signature r - Date FINALAPP.FRM T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fav (206) 575-4439 DESIGN CALCULATIONS (NEPA 13D) RESIDENTIAL FIDE SPRINNKLBR SYSTEM Activity I - Sheet No: 1 'of 1 haste: November 1, 1996 By: J A Lynch Project Names New residence - Northwest Development Trust Floor LeVelt_One wfbasement Project Location: 2308 So 130th, Tukwila, wA - Lot #19 Available Nater Supply: 26 g.p.m. at: 90 Max Sprinkler Spacing: 16 Elev. of Spkrst 8' p.s.i. Location, 1" Meter at So 130th ft. X 16 ft. Sprinkler I.D! Central R.O.C. Pendent ONE. -SPRINKLER DESIGN: Min. Flow: 18 gpm; Min. TWO -SPRINKLER DESIGN: Min. Flow: 26 gpm: Min. press: 18.4p9i press: 9.6psi Type of Piping: X crvc rvc Steel (Sch. 40) Copper it, L, M (Circle one) CALCULATIONS 2 Sprinkler flow: System demand - 26 gpm CALCULATIONS 1 Sprinkler flow: System demand = 18 gFrn PIPING (1 spkr flow) TOTAT. tfNTT _ TOTAL DIA. LENGTH X FR LASS PR LOSS Service (PVC) System (CPVC) 1" 1" 38' 64' .0541 2.06 11 3.46 Plus 151 .83 FITTINGS 6 VALVES (1 spkr flow) OTA.& X Unit X TOTAL ;UNIT TOTAL TYPE QTY. EQ.LEN.F,Q.T.EN.X FR.LOSS FR.f.OSS 1 " 9 0 ° i, � _ _Z_ 7' 1"T Rn 8 1' 8' 1"T Br 6 5' 30' 1"Fl Sw 1 4' 4' 1", Double check BFP .0541 .38 METER FRICTION LOSS (Size= 1") SPKR PRESSURE REQIITRED ELT'•VATTON ITP.AD LOSS ( l8- X 0 TOTAL SYSTEM PRESSURE DEMAND TOTAL SUPPLY PRESSURE AVAILABLE 434) .43 1.62 .22 4.00 2.00 18.40 41.21, r776771 PIPING (2 spkr. flow 2'26 qpm) TOTAL 1[ UNIT TOTAT. DIA LENGTH FR LOSS• , PR LOSS Service (PVC) 1" 38' .1067 4.06 System (CPVC) 1" 64' '' 6.83 rlt:n 1S1 1.63 PITTINGS. i .VALVES ,(2-spkr. flow - 26 gpm) PTA 6, TYPE 1"90°L 1"T Rn 1"T Br 1"F1 Sw 1 4' 4' 1" Double check BFP UNIT TOTAL UNIT TOTAL. QTY X 10Q L.RN*.EQ 1.10' PR ®+P�t • . LOSS 1 7' 7' .1067 8 1 8 6 5' 30' 11 METER PRTC ION LOSS (sire1") • SPRTNItT.ER PRESSURE. REQUIRED . T'T,EVATTON nRAn toss ( 18 ft X .434) .TOTAL SYSTEM PRESSURE DEMAND TOTAL, St,rr,,Y PRESSURE AVAILABLE .75 -7117- 3.20 .43 4.00 3.00 9.60 �4` 1 90.00 __ 1 NORTRWP.ST RRSIfRNTIAL FIRE SPRINRLER INC 1675 Pthridge Ave. NE Olympia, NA 98506 (2061754-6475 FAX (206)459-3561 Contrnctor's Reg. INNRESFS08513A /J 4\k‘k 163216 1 e 114/17N 446 .,n' 4 UT/.4 w• a - £i,/C/N/.SH O /3,4: M1 �S/T' .SC d J` g 1 Main Drain rTo Sprinkler System RISER DETAIL No Scale dem/." 00 00 DC ap ,4-44,47R la,PY NOTE: L To Domestic r From Supply Control Valve sack i<<a,�-�.�.T�,�� ACCEPTED © WITHOUT COMMENTS ,],AS NOTED IN REL) El PER THE ATTAC 1ED LETTER The drawings affixed hereto have peen reviewed and accepted by the Citv of Tukwila Fire Dept Additions, del k ins or revisions to these Jrawi igs aft us date will void this ac33 atanoe an ill require a resubmittal of revised drawings Final acceptance is subject to field inspection by a representative of this department DATE it (aVo BY�c� S�C7 CITY OF TUKWILA 575 4407 TUKWILA FIRE OEPARTMENl Please call 575-4407 and give this job No. and exact address for shuts down or restoration app ALL SPRINKLER PIPING TO 1' CPVC FUM SNITCH TO BE POTTER 120V , ALAI BELL TO BE POTTER 66, 120V BFP TO BE PEBCO MODEL 805T DOUBLE CHECK SPRINKLERS TO BE CENTRAL /j'XCONCEALED PENDENT !MAIN FLOOR -..- -- 2,0 FA UPPERmow -------------- 7 PA BASEMEMENT EA TOTAL -------- .- t1 C'V 4 19S6 A g �� _i 5'7fcF ul M • vD Tr Tr LO 1 Tr 0 wl Tr • 1 CD O 00 C4 i 00 0 w DATE. f/ /94 BY 4"" : if„,, G� 11', 1 g -80?)