HomeMy WebLinkAboutPP - 4062 S 128TH ST - WANG CHENG RESIDENCE - PERMITS AND PLANS4420 S 118TH ST ASSOCIATED PERMITS OO -S-1 za D98-0360 FILE City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief December 10, 1998 Fire Department Review Control #D98-0360 (511) Re: Stenson Construction - 4420 South 118th Street Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. For short plat development' (four single family homes or less), hydrants shall be placed so that a hydrant is within 250 feet of a building. Distance from a hydrant to a building is measured along the path of vehicular travel. (City Ordinance #1692) Fire hydrants shall conform to American Water Works Association specifications C-502-54; it shall be compression type, equipped with two 2 1/2" N.S.T. hose ports and one 5" Storz pumper discharge port, and shall have a 1 1/4" Pentagon open -lift operating nut. (City Ordinance #1692) The minimum fire flow and flow duration requirements for one- and two-family dwellings having a fire area which does not exceed 3,600 square feet (344.5 m2) shall be 1,000 gallons per minute (3785.4 L/min.). Fire flow and flow duration for dwellings having a fire area in excess of 3,600 square feet (344.5 m2) shall not be less than that specified in Table A -III -A-1. Exception: A reduction in required fire flow of 50 percent, as approved by the chief, is allowed when the building is provided with an approved automatic sprinkler system. (UFC Appendix. III -A, sec. 5.1) 2. In lieu of a fire hydrant, an approved residential fire sprinkler system may be installed when vehicular Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206)575-4404 • Fax (206) 575-4439 Cizy of TukwiLa - FILE_ Steven lel Mullet, Mayor Fire Department TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name S� LN$0a/ `oArs j • Address L/y%) 5 //8 i' Thomas P. Keefe, Fire Chief Permit No. Retain current inspection schedule Needs shift inspection Suite # Approved without correction notice Approved with correction notice issued Sprinklers: /31) Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Sign ture FINALAPP.FRM Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439 U MITT)L SERIAL NO:2022HY3 HEAD CALCULATION FLOW TEST RESULTS Water Supply STATIC 134.00 PSI RESIDUAL 20.00 PSI @ 1350.00 GPM 03-20-2000 PAGE 1 CITY PRESSURE AVAILABLE AT 32.7 GPM 133.88 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K -FACTOR PRESSURE 18 14.68 13.00 4.20 12.22 19 13.00 13.00 4.20 9.58 TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 4 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 27.68 GPM 5.00 GPM 32.68 GPM 114.49 PSI MAXIMUM PRESSURE UNBALANCE IN LOOPS 0.00 PSI MAXIMUM VELOCITY FROM 5 TO 7 14.80 FPS SUBMITTAL SERIAL NO:2022HY3 (2) HEAD CALCULATION 03-20-2000 PAGE 2 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 18 19 0.874 L 14.00 C=150 PT 9.58 ( 19) Q 13.00 F=2E F 14.00 PE 0.00 BN T 28.00 0.0944 PF 2.64 10 18DQ 14.68 0.874 L 41.00 C=150 PT 12.22 ( 18) Q 27.68 F=3T,4E F 37.00 PE 1.30 BN T 78.00 0.3822 PF 29.81 7 10 0.874 L 17.00 C=150 PT 43.33 ( 10) Q 27.68 F=T,4E F 31.00 PE 3.90 BN T 48.00 0.3822 PF 18.35 5 7 0.874 L 22.00 C=150 PT 65.58 ( 7) Q 27.68 F=3E F 21.00 PE 1.73 BN T 43.00 0.3822 PF 16.43 4 5 1.049 L 4.00 C=120 PT 83.74 ( 5) Q 27.68 F=T,E,DCA F 7.00 PE 1.73 FR T 11.00 0.2375 PF 2.61 1" AMES 2000B DOUBLE CHECK ASSEMBLY 5.95 2 4DQ 5.00 0.995 L 25.00 C=150 PT 94.03 ( 4) Q 32.68 F=GV,4E F 5.00 PE 1.73 UN T 30.00 0.2764 PF 8.29 1 2 1.481 L 150.00 C=150 PT 104.05 ( 2) Q 32.68 F=4E F 12.00 PE 0.00 UN T 162.00 0.0398 PF 6.45 0 1 1.481 L 40.00 C=150 PT 110.50 ( 1) Q 32.68 F=T,GV,RPV/2E F 12.00 PE 0.43 UN T 52.00 0.0398 PF 2.07 1 1/2" WATER SERVICE METER 1.45 PT 114.46 ( 0) puewap ieq.ol ISd 617't"TT aounoS q.e asoH r• r• r•r r• 7C W o 3 3 (0 - 0 <D -3• 3 o N 1.11 aQ ISd L9'601 rmrep W N N OUl�l 0)000, 00 0 0 CO G) G) G) G) -0 -0 -0 -0 3 3 3 3 m 0 1 11 2 f'l i) (1) r (� r+ (0 U) 0) 0) C•-• • ri- a) +0) Q (p r+ C () -7 0) 0 r. 3 Y! c N H •a O O W - A`C 0 0 • • 0 0 0 ' 0 0 0 (f)(f)-0 H U] (m Wd9 00'OSET 0 0 0 0, 0 0 0, 0 Pressure (PSI) : s - _i.,Y.i,.aso Nimomrii 111111 1Fri1r,, A„or gin sure 19.4 487.7 I 2 m D 0 r- "4 V co y _. 0 CO 03 (n cco co v� v� •c m —3 00 o a+ 3 0 m o 0 0 a0 Ci) V 0 7"7 SUBMITTAL SERIAL NO:2022HY3 • (`1) HEAD CALCULATIOM FLOW TEST RESULTS Water Supply STATIC 134.00 PSI RESIDUAL 20.00 PSI @ 1350.00 GPM CITY PRESSURE AVAILABLE AT 23.0 GPM 133.94 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K -FACTOR PRESSURE 19 18.00 18.00 4.20 18.37 TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 4 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 5 TO 7 18.00 GPM 5.00 GPM 23.00 GPM 79.54 PSI 0.00 PSI 9.63 FPS 03-20-2000 PAGE 1 SUBMITTAL SERIAL NO:2022HY3 03-20-2000 PAGE 2 (1) HEAD CALCULATIOM Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 18 19 0.874 L 14.00 C=150 PT 18.37 ( 19) Q 18.00 F=2E F 14.00 PE 0.00 BN T 28.00 0.1724 PF 4.83 10 18 0.874 L 41.00 C=150 PT 23.20 ( 18) Q 18.00 F=3T,4E F 37.00 PE 1.30 BN T 78.00 0.1724 PF 13.45 7 10 0.874 L 17.00 C=150 PT 37.95 ( 10) Q 18.00 F=T,4E F 31.00 PE 3.90 BN T 48.00 0.1724 PF 8.28 5 7 0.874 L 22.00 C=150 PT 50.13 ( Q 18.00 F=3E F 21.00 PE 1.73 BN T 43.00 0.1724 PF 7.41 4 5 1.049 L 4.00 C=120 PT 59.27 ( 5) Q 18.00 F=T,E,DCA F 7.00 PE 1.73 FR T 11.00 0.1071 PF 1.18 1" AMES 2000B DOUBLE CHECK ASSEMBLY 5.70 2 4DQ 5.00 0.995 L 25.00 C=150 PT 67.88 ( 4) Q 23.00 F=GV,4E F 5.00 PE 1.73 UN T 30.00 0.1443 PF 4.33 1 2 1.481 L 150.00 C=150 PT 73.94 ( 2) Q 23.00 F=4E F 12.00 PE 0.00 UN T 162.00 0.0208 PF 3.37 0 1 1.481 L 40.00 C=150 PT 77.31 Q 23.00 F=T,GV,RPV/2E F 12.00 PE 0.43 UN T 52.00 0.0208 PF 1.08 1 1/2" WATER SERVICE METER 0.73 ( 1 PT 79.54 ( 0) 0 – I () (p .- 0 0 0D �+a o Cu Mh �' w ~ Cu r• 7 w G 0r+0CD r—o 3 (n0) ) 0 N O ►- DC -9 m c▪ n 0 0 ' - 3 z O r0 0 W Q) '" a CL V V O C0 0) ISd b5'6L O 0) U) ra) rm N F� wOwCO O 0 0 0 0 0 0 0 to 0 G) G) G) GI 3 3 3 3 co O 2 ri Z)wG r0 10 N 0) C •-" c+ r•► 0) aCD L.+ C 0 . N 0 3 C O O w — �� 0 0 • • 0 0 0 • 0 Wd9 00'05C1 0 0 0 tinkled') 0) v CO CO o 41 o Pressure (PSI) O N w A p1 0) o o 0 a-.0 0 0 ro N -.a CO CO o 0 0 0 0 0 0 w 4.c▪ (n 0 0 0 O woiivino-ivo ciV2H cn O CO 03 0m co .gym —3 vF. mw 3 n m a. -0 m cto 0-0 , o 0 NI FA li ri Margin Pressure 54.40 PSI Flow 882.92 GPM f 61I O woiivino-ivo ciV2H cn O CO 03 0m co .gym —3 vF. mw 3 n m a. -0 m cto 0-0 MAX. HANGER SPACING %I l I ! .! 1 ti • Oo r.rtJt!t i'XF77 74Z r I • 41) u tbN.G. 110v es Or. elprifirk r M Id_ P_ Ue -co lap • • • • s s t s •s 1 • S s Seo FL=C `i s S r s 4:4-;Z, 1 i 4, • 4i 1Y • • 111P►sss:. ••••linKgisr s. / d • KESTREL UWW.PRINT $ICJ 19111! Itt r 1 I4 14 r(—Tr 1T' jf TWO _&:ts0,- OPP061,,t 600W aroi caw FP'fT "970 0+4 Gwp-' t�l�r'a �t.p• IM 1" Documented Flow Characteristics (Including shut-off varves) PRESSURE DROP - PSIG 12 10 6 6 4 2 0 01 10 20 30 FLOW - GPM 40 50 60 3 SPARE HEAD BOX • t,t 0 te" �.L. f,EZ?xM 0 -e • O 66, a oor► f•Jrr?P-r I • _L-IUItJ!/� 0 • 1" CENTRAL RISER MANIFOLD W/: (1) DRAIN AND TEST RUN TO THE EXTERIOR (2) FLOW SWITCH TIE INTO THE 6" BELL (3) PRESSURE GAUGE (4) SIGNS ON BODY AMES 2000B DOUBLE CHECK ASSEMBLY ADVANCED FIRE PROTECTION 'STARTS HERE 0 R 4-0t t 4,;14.Ate. Per vF/7 -!3 D TUB OUT BY OTHERS SFR DI- A I L - (1421Go YIN Ld 10.0 G1,fR- ►Tc7(& ( CPVC PPE HEX HEAD Elf \ TArPra OolIIw DOUBLE FASTENER CPVC PIPE STRAP v" HANGER A PUCAMON IE( HFAD SELF TAMEW I. r SINGLE FASTENER CPVC PIPE STRAP NOMINAL PIPE SIZE 5 1/2' 6' 6 1/2' 7 a' NOTE: A WAGER UM OE VIEW s• OF FA MOP 4\4> BATT INSULATION '(BY OTHERS) NOTE: HEAT FROM BELOW CEILING MUST BE ABLE TO GET TO SPRINKLER PIPE NOTES 1) THIS SYSTEM IS DESIGNED PER NFPA 13D. THE PIPE SIZING WAS DETERMINED BY A 1 AND 2 HEAD HYDRAULIC CALCULATION. 2) THE SPRINKLER HEADS ARE CENTRAL OPTIMA CONCEALED 7/16" 160' MAX SPACING OF 16' x 16'. 3) THE PIPE AND FITTINGS ARE 3/4" CPVC EXCEPT FOR THE 1" STEEL RISER. 4) THE 1 1/2" DOMESTIC/SPRINKLER SUPPLY IS DONE BY OTHERS. BRANCHLINE • CEILING SPRINKLER NO INSULATION UNDER THE PIPE HEAD ATTIC DETAIL r� SECTIO\ ACC [j Without Comments gr As Noted In Red Per The Attached Letter These plans have been re -viewed by The Tukwila Fire Prevention Bureau for conic t -m nce with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to thse drawings after this date will void this acceptance and will require a resubmittal of revised drawings tor subsequent approval. :Ina! acceptance is subject to field test and inspection by r The Tukwila Fire Prevention Bureau. Date: - Y-00 By: s l 1 5Flo+,. fit- ,AT:014 TUKWILA FIRE DEPARTMENT Please call: 575-4407 and'give this job Na. 00 - and exact address for shute down or restoration approval Residential Optima Concealed Pendent (Non•Aclivaled) 3 to SITE A.' rteciOG. • ne. 14"usa Deeeto Dc, D(36,0 Design Requirements—Residential Optima Concealed Coverage Area (h. x Y.) Single Head Multiple Head Minimum Flow Nam) Minimum Pressure (psi) Minimum Flow (Sam) Minimum Pressure (vs.) 20,x 20 t.a K. til 24 32.7 17 13.4 is x13132414:0 24 32.7 17 16.4 18 X 13lisa 14. a,: " 18 _....._ 18 4^ " ,� 13 r` 79:8T 14 x 14pa4s4.1.1 18 13.4 13 9.6 12 x 12(1µ14.t, 18 18.4 13 9.8 Caution: Minimum spacing between sprinklers is d'. SPRINKLERS UPRIGHT PENDENT • 1,Z tion SIDEWALL 0 P.O. BOX 1543 WOODINVILLE, WA 98072 (206) 483-5657 27--NV/k