Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 4603 S 124TH ST - BARRIER RESIDENCE - PERMITS AND PLANS
4603 S 124TH ST ASSOCIATED PERMITS 16-5-033 D15-0219 Ottliw44 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: 4603 South 124th Street Tenant Name: Barrier Residence Property Owner's Name: Barrire construction King Co. Assessor's Tax No.: 017900 3005 Suite Number: Floor: New Tenant? ❑ - Yes ❑ - No Mailing Address: 42 South 132nd Street Burien WA 98168 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Phil France Company Name: SureFire sprinkler Corp Day Telephone: 206-793-7688 Mailing Address: P 0 Box 719 Ravensdale WA 98051 City State Zip E-mail Address: Phil©surefiresprinkler.com Fax Number: Contractor's City of Tukwila Business License number: In for application Total number of new/relocated devices or sprinkler heads: 28 Valuation of Project (contractor's bid price): $ $ 7,250.00 Scope of Work (please provide detailed information): Design, and install new wet sprinkler asystem to protect the new residence. SFSC to start inside the building, at a 1" outlet left by others. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTH i . D AGENT: Signature: Date: 2/17/16 Print Name: Phil France Day Telephone: 206-793-7688 Plan Permit App.doe 8/22/14 TFD FP Form 8 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 02-t /6-S /(o -S -033 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: (.er las Ty. of Inspection: "fr- 61.0 --- fin/ PC I Address:_ Suite #: y603 �,�1 " Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. COMMENTS: Corrections required prior to approval. c 6�.Qi f fie T— 41 2- 14e -tie 6vA-( Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: , Occupancy Type: Inspector: tel/ " Date: //3,/, -7 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit IL-5' 033 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project.. Sprinklers: Fire Alarm: Hood & Duct: Type.1 Inspectio Pre -Fire: Address: Suite #: 'pd3 2 2. 12� :. Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: /-694-0 QT-_ du Pre -Fire: Permits: Occupancy Type: &jac -r-- 7 --PT- <L_ NE -2>k 1O S4( 3d see_ tii PPrz Q-4106 2©x20 leen Spa rPt ry Alo f7V217S aA 1 Tr- /vr us -r-- f,2 -vi P- 4-u, f n- t cro-i s t— pa - 7 -6 , Perk IFG lori-o -, Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: / Inspector: T YY 1 44--- Date: 12fr2.111:, Hrs.: ' $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Z INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Proje e—e_s Type of Inspection: COOL(' Address:Contact Suite #: V6o3 S • L`fek Sr Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COM E NTS: 4g- -fa C'av�r /we/sr fi,f-Avi-s ON S. it Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector - `� Date: 573/ 14 Hrs.: /- U V ' / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 5 -4-h r,NJ Type of Inspection: CED -o Address:Contact Suite #: V6Cy3 S / 241-1\5 r Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: acro feriut:11 o•.) s� 75- -SPG ���� /°abs e,,j -7 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: J yl5 Date: y/fie //G Hrs.: its $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 II 1 Hydraulic Summary Job Number: 201604 Report Description Residential Job Job Nu,, 201604 Dorian Engin., PHIL FRANCE Job Name: BARRIER RESIDENCE Slot.C. udonAjcrie. Numb., SUREFSC856DD Adtrw 1 4603 SOUTH 124 TH STREET AHJ TUKWILA FIRE DEPARTMENT Aai...2 TULWILA, WA. Job SIYI&idin LEVEL 2 CORRIDOR Addy.. 3 Onming Name RES CALC PLAN.cad System Remote Area(s) Met D.m.ning Sp ,Id., NM 4.9 K -Factor 20.00 at 16.660 Oocupenoy Residential Job Sults Hoes Allowance At Sour. 0.00 Dorn. 0.050gpm/ft2 Area of Application 900.00ft2 (Actual 64.97ft2) Additional Hoes Sup... Node Flow(aom) Number Of Sprinklers Cakul nd 2 Cowng. Per Sprints., 400.00ft2 Hose At Node 8 15.00 A° R.4 Pram. For Ramo. Mea(.)M}..ntToMoe Rroo Area Left: 129.289 Right: 130.361 Total How Stream. 15.00 Sya.o Flow Demand 55.02 Total Water P.O.W. (Including HoesMowan.) 55.02 Mndmum P...a. UMW.. In Loop. 0.000 Medmum Velocity Mow Grand 29.42 between nodes 6 and 5 Metsmum Velocity Under Grand Volum. opacity ol Wet Pipes 14.67ga1 Volum..padty of Dry Pipes Supplies Node Name Hose Flow (gpm) Static (psi) Residual Flow (psi) (gpm) Available C, Total Demand (psi) (gpm) Required (psi) Safety Margin (psi) 6 Water Supply 150.000 20.000 1000.00 149.392 55.02 129.923 19.469 WASHINGTON STATE CERTIFICATE OMPETENCY FIRE PROTECTION SPR SPRINKLER SYSTEMS PhD France 0061-0292-C Level 3 Surefire .r - - er Corporation SU" ; : .DD o Expires n - Te 12/31115 L ` : J o Contractor Contractor NunberConhG 22 Name PHIL FRANCE CancKt Title Nem. or Contractor. SUREFIRE SPRINKLER CORP. Phone 206-793-7688 Exhnaon Md.. 1 POBOX719 FAX Ark.. 2 RAVENSDALE, WA. 98051 E•mai phil©surefiresprinkler.com Add.. 3 Wab•Slr gA, ® M.E.P.CAD, Inc. AutoSPRINKS VRI 1 v11.0.39.0 2/17/2016 1:27:10PM Page 1 111 Node Analysis Job Number. 201604 Report Description: Residential Node Elevation(Foot) Fittings Pressure(psl) Discharge(gpm) 6 -3'-0 S 129.923 55.02 8 0'-6 Hose 78.803 15.00 101 18'-6 Spr(-16.660) 16.660 20.00 102 18'-6 Spr(-16.695) 16.695 20.02 1 19'-0 T(3'-(1) 17.176 2 19'-0 T(3'-0) 31.759 3 9'-6 T(3'-0) 70.010 4 0'-6 T(5'-0), Tr(1'-0) 79.023 5 -3'-0 WMV(-10.000) 116.302 7 19'-0 T(3'-0), Tr(1'-0) 17.213 f , ® M.E.P.CAD, Inc. AutoSPRINK® VR11 v11.0.39.0 2/17/2016 1:27:12PM Page 3 11 Hydraulic Analysis Job Number: 201604 Report Description Residential Pipe Type Diameter Flow Velocity HWC Friction Loss Length Eq. Length Total Length Pressure Summary Downstream Upstream Elevation Discharge K -Factor Pt Pn Fittings w Route 1 DR 0.8740 20.00 10.70 150 0.209466 0'-6 3'-0 3'-0 Pf 0.733 Pe -0.217 Pv 101 1 18'-6 19'-0 20.00 4.9 16.660 17.176 Sprinkler, T(3'-0) BL 0.8740 18.52 9.91 150 0.181748 49'-2% 31'-0 80'-2% Pf 14.583 Pe Pv 1 2 19'-0 19'-0 17.176 31.759 cplg(1'-0), 2T(3'-0), 3Tr(1'-0), 3E(7-0) BL 0.8740 40.02 21.40 150 0.755875 18'-2 27-0 45'-2 Pf 34.132 Pe 4.119 Pv 2 3 19'-0 9'-6 21.50 31.759 70.010 Flow (q) from Route 2 3E(7'-0), 2T(3'-0) BL 1.1010 40.02 13.49 150 0.245531 12'-9% 8'-0 20'-9' Pf 5.111 Pe 3.902 Pv 3 4 9'-6 0'-6 70.010 79.023 E(T-0), Tr(1'-0) BL 1.1010 55.02 18.54 150 0.442435 51'-2% 7'-0 58'-2' Pf 35.762 Pe 1.517 Pv 4 5 0,-6 4-0 15.00 79.023 116.302 Flow (q) from Route 3 E(T-0), WMV(-10.000) BL 0.8740 55.02 29.42 150 1.362049 10'-0 10'-0 Pf 13.620 Pe Pv 5 6 -3'-0 -3'-0 116.302 129.923 Water Supply 0.00 Hose Allowance At Source 6 55.02 G Route 2 DR 0.8740 20.02 10.71 150 0.209882 0'-6 3'-0 3'-6 Pf 0.735 Pe -0.217 Pv 102 7 18'-6 19'-0 20.02 4.9 16.695 17.213 Sprinkler, T(3'-0) BL 0.8740 21.50 11.50 150 0.239422 43'-9 17-0 60'-9 Pf 14.546 Pe Pv 7 2 19'-0 19`-0 1.48 17.213 31.759 Flow (q) from Route 4 2T(3'-0), 4701 '4)), E(7-0) ® Route 3 BL 1.1010 15.00 5.05 150 0.039961 0'-6 5'-0 5'-6 Pf 0.220 Pe Pv 8 4 0'-6 0'-6 15.00 78.803 79.023 Hose T(5'-0) G. Route 4 BL 0.8740 1.48 0.79 150 0.001689 20'-0 2'-0 22'-0 Pf 0.037 Pe Pv 1 7 19'-0 19'-0 17.176 17.213 2Tr(1'-0) Equivalent Pipe Lengths of Valves and Fittings (C=120 only) II C Value Multipger Actual Inside Diameter ( 4 =Fador Value Of C 100 Multiplying Factor 0.713 130 140 150 1.16 1.33 1.51 Schedule 40 Steel Pipe Inside Diameter )4.87 ,, ® M.E.P.CAD, Inc. AutoSPRINK® VR11 v11.0.39.0 2/17/2016 1:27:13PM Page 4 Bi! Hydraulic Analysis Pipe Type Downstream Upstream Diameter Elevation Flow Discharge Job Number 201604 Report Description: Residential Velocity HWC K -Factor Pt Pn Friction Loss Fittings Length Eq. Length Total Length Pressure Summary Pipe Type Legend Units Legend Fittings Legend AO Arm -Over BL Branch Line CM Cross Main DN Drain DR Drop DY Dynamic FM Feed Main FR Feed Riser MS Miscellaneous OR Outrigger RN Riser Nipple SP Sprig ST Stand Pipe UG Underground Diameter Elevation Flow Discharge Velocity Pressure Length Friction Loss HWC Pt Pn Pf Pe Pv Inch Foot gpm gpm fps Psi Foot psi/Foot Hazen -Williams Constant Total pressure at a point in a pipe Normal pressure at a point in a pipe Pressure loss due to friction between points Pressure due to elevation difference between indicated points Velocity pressure at a point in a pipe ALV AngV b BalV BFP BV C cplg Cr CV DeIV DPV E EE Eel Ee2 f fd FDC fE fEE fig FN fT 9 GIoV GV Ho Hose HV Hyd LtE mecT Noz P1 P2 PIV PO PRV PrV red S sCV Spr St T Tr U WirF WMV z Alarm Valve Angle Valve Bushing Ball Valve Backflow Preventer Butterfly Valve Cross Flow Tum 90° Coupling Cross Run Check Valve Deluge Valve Dry Pipe Valve 90° Elbow 45° Elbow 11%* Elbow 22'/:° Elbow Flow Device Flex Drop Fire Department Connection 90° FireLock(TM) Elbow 45° FireLocic(TM) Elbow Flange Floating Node FireLock(TM) Tee Gauge Globe Valve Gate Valve Hose Hose Hose Valve Hydrant Long Tum Elbow Mechanical Tee Nozzle Pump In Pump Out Post Indicating Valve Pipe Outlet Pressure Reducing Valve Pressure Relief Valve Reducer/Adapter Supply Swing Check Valve Sprinkler Strainer Tee Flow Tum 90° Tee Run Union Wirsbo Water Meter Valve Cap 0 M.E.P.CAD, Inc. fit AutoSPRINK® VR11 v11.0.39.0 2/17/2016 1:27:13PM Page 5 iii(HydraulicGraph _ Job Number: 201604 Report Description: Residential Water Supply at Node 6 Pressure, psi n 8 $ 8 8 8 8 $ 8 8 E 11111 111111111 11111111111 Ilili!11111111111 111 11 1 i,t t1l 111111 11 1itil itt1111111111111111111 Static Pressure 150.000 55.02 129.923 Stem demand curve 1000.00 @ 20.000 ®W111111 111111111 11J 1 1 1 1 11 1 1 1 1 1 1 1 1 1 1 1 1 1_ 1 1 1 1 1 1 1 1 1 1 1 1 1 1 L 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 200 400 600 800 1000 1200 1400 1600 1800 2000 Water flow, gpm Hydnuec WW1 Water Supply at Node 6 Static. Prem. 150.000 Residual: Pyre ro 20.000 @ 1000.00 Av.kbI. Prem. et Tim. of Test 149.392 @ 55.02 System Demand 129.923 © 55.02 System Demand (Including Her M ...nee .t Sown) 129.923 @ 55.02 (�, ® M.E.P.CAD, Inc. AutoSPRINK® VR11 v11.0.39.0 2/17/2016 1:27:11 PM Page 2 LEVEL 2 CORRIDOR, RESIDENTIAL REMOTE AREA. .0512 HEADS. MAX HEAD SPACING 400 SQ. FT SYSTEM DEMAND @ B 0 R 40.2 GPM @ 79.0 PSI .75" SUPPLY DOWN TO LEVEL 1 BEDROOM BEDROOM BEDROO OFFICE EXISTING .75" DOMESTIC SUPPLY LONE FROM CIT5Y MAIN IN46TH AVENUE SOUTH. KITCHEN CLST EXISTING .75" DOMESTIC METER .75" SUPPLY DOWN TO OUTLET, LEFT BY PLUMBER, SUPLY FROM TOILET DINING LIVING BEDROOM GEN SPACE BEDROOM .75" SUPPLY DOWN TO OUTLET, LEFT BY PLUMBER, SUPLY FROM TOILET ENTRY 2 STORY ENTRY SCALE: 1/8" = 1"-0 ALL PIPE & FITTINGS TO BE CPVC MAXIMUM SPRINKLER SPACING 20' X 20', 400 sq. ft MAXIMUM SPRINKLER SPACING 10' - 0" OFFANY WALL SCALE: 1/8' =1"-0 ALL PIPE & FITTINGS TO BE CPVC MAXIMUM SPRINKLER SPACING201X 20', 400 sq. ft MAXIMUM SPRINKLER SPACING 10' - 0" OFF ANY WALL CPVC HANGER SUPPORT SPACING SIZE Hanger No. 19W Offset Pipe Hanger 74- Pin. 3/4" WcodStrewalDx I' G-0 G-6 11/2 T-0 2 G-0 21/2 G-0 3 1G-0 4,41.14,ope Hong. lk / / / / / • i'T ', , 4 g ^ / , , e , / / / .e. / / / / / / / / / / / / / / / / / / / / -,..* ---. / / / / / / / / / r r N— Wood I hitt Deem or Deck CPVC HANGER SUPPORT SPACING SIZE SPACING 3/4" T-6 1" G-0 11/4 G-6 11/2 T-0 2 G-0 21/2 G-0 3 1G-0 1 " SUPPLY TO RESIDENTIAL AREAS 1" BALL VALVE, WATERFLOW INDICATOR, 1" MAIN DRAIN, AND PRESSURE GAGE CPVC HANGER SUPPORT SPACING TO IN LINE SPRINKLER DROP TEE SFSC TO START AT 1 " OUTLET, BY OTHERS SIZE LESS THAN 100 PSI GREATER THAN 100 PS 3/4" T-0 4-0 T-0 AFCON # 24 or TOLCO 4511 Pipe Strap 11/2 7.-0 7'-0 Weed &new ente r CPVC HANGER SUPPORT SPACING TO END LINE SPRINKLER DROP ELBOW SIZE LESS THAN 100 PSI GREATER THAN 100 PSI Woad lois( orS• 3/4" 1" 1 1/4 0-9" 10-4 11/2 2-0 0-6" 0-9" 10-0 MINIMUM DISTANCE OF SPRINKLERS TO HEAT SOURCES FRONT OF FIREPLACE 5'4:1 SIDE OF FIREPLACE 3'-0 KITCHEN STOVE l'-6 CEILING MOUNTED DIFFUSER HOT WATER HEATER 0'-6 FURNACE W-6 LIGHT FIXTURE 0'-6 1 " DOMESTIC SUPPLY OUTLET, BY OTHERS --- 1 " SUPPLY FROM CITY BY OTHERS - RISER DETAIL SCALE: NONE o Without Comments As Noted in Red 0 Per The Attached Lett plans have been reviewed by The Tukwila Fire r.rovention Bureau for conformance with current City nrds Acceotarze ;7ubject to errors and nissions which do dloriZe violations of adopted -3ndards and 1l -i€7, responsibility or the 40le.quacy of with the designer. deleksion!i, to il:hese drawings after tNs date will void i?ind will require a submittal of revs (iTT.000V5 kipset.i-uent approval. Final acceptance is subject to field test and Inspection by "ale Tukwila Fire Prevention Bureau. Date: l CPVC PIPING TO BE CONCEALED ABOVE CEILINGS OR IN WALLS COVERED WITH A MINIMUM OF 3/8" GYPSUM DRYWALL. EXPOSED PIPING IS ACCEPTABLE WITHIN LIGHT HAZARD OCCUPANCIES. ALL PIPE & FITTINGS TO BE BLAZEMASTER CPVC CONNECTED WITH TFP-500 ONE-STEP CEMENT BLAZEMASTER PIPING CONFORMS TO ASTM 442 AND IS UL LISTED BLAZEMASTER FITTINGS MEET ASTM F438 REQUIREMENTS FOR SCHEDULE 40 DIMENSIONS FROM 3/4" TO 1 1/2" AND ASTM 439 REQUIREMENTS FOR SCHEDULE 80 DIMENSIONS FROM 2" AND LARGER. MAXIMUM SPRINKLER SPACING 20' X 20', 400 sq. ft_ MAXIMUM 10' - 0" OFF ANY WALL MINIMUM 8-0 BETWEEN SPRINKLERS SPRINKLERS MUST BE SPACED TO CEILING OBSTRUCTIONS TO PREVENT BLOCKAGE PER NFPA 13D SYSTEM DESIGN PER NFPA # 13 D NT r es ra al in mu Ns es in re mg tai Ili um in um gm TMITA CIPTTICTOMPENCY FIRE PROMCTION SPRINKLER SYSTEMS Phil France 0061-0292-C Level 3 Surefire Sprinkler Corporation SUR-. ..56DD "./ AL Expires • r 12/31/1 61 WI 1 MI VI OS 161 MI CU =I MMMMMMMM MM Ph'e ooem`.42112-c Lowe13 8VRE E Revisions NORTH Sprinkler Information Symbol Sprinklers • Type Degree Qty GL4906 K=4.9 GL 5606 K=5.6 PENDENT PENDENT 155 200 22 2 VIC V3607 K=5.6 DRY PENDENT 155 4 TOTAL THIS SHEET: 28 Standard Symbols L>l< - Post Indicator Valve r>l< - Key Operated Valve - Public Hydrant oo - Fire Dept. Connection pi< - 0.S.&Y. Gate Valve - Check Valve / New Underground A = 4 - Existing Underground Standard Symbols - Alarm Check Valve - Thrust Block Backflow Preventer Sprinkler Head Symbols Inspections -0- - Upright On 1/2" Outlet -0- - Pendant On 1" Drop Bel. Ceiling - Upright On 3/4" outlet -0- - Upright On 1" Stubb-up -0- - Upright And Pendant On Drop - SideWall On 1/2" Outlet - Sidewall On 1" Outlet 2. 3. 4. 5. SureFire Sprinkler Corporation PO Box 719 Ravensdale, WA 98051 Job No. Date Engr. Scale 201604 02/19/16 P France BARRIER RESIDENCE 4603 S. 124th STREET TUKWILA, WA. LEVEL 1 &2 1 OF 1 1/8" = 1-0