Loading...
HomeMy WebLinkAboutPP - 14205 34TH AVE S - BURN LOT 1 - PERMITS AND PLANS14205 34TH AVE S ASSOCIATED PERMITS 19-5-081 D18-0147 IrIZTREC CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION 553720-0116 King Co. Assessor's Tax No.: Site Address: 14205 34th Avenue S - Qur Lc+ Suite Number: Floor: (new construction) Tenant Name: Property Owner's Name: Cary Lang Construction Mailing Address: 29815 24th Ave SW New Tenant? ❑ - Yes E- No Federal Way WA 98023 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Jake Box Day Telephone: (307) 251-1701 Company Name: Glacier Fire Protection, LLC Mailing Address: PO Box 7980 Bonney Lake WA 98391 jakeb@glacierfp.com City State Zip E-mail Address: Fax Number: N/A NICET III number: Erin Clayton 7544-0817-C Business Licn City number: of Tukwila 0998044 Total number of new/relocated devices or sprinkler heads: 24 Valuation of Project (contractor's bid price): $ 7,000.00 Scope of Work (please provide detailed information): Design & install fire sprinkler system in new constructed 1 family dwelling per NFPA 13D. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Jake Box °nail"' stoned p/: on..bke Bon.o- oer Five Protection, on. emelyeke444.0 15:5 me, cN5 Signature. OMe: 1919.M.1<15:S9:M 09 Print Name: Jake Box Plan Permit App.doc Date: 4/14/2019 Day Telephone: (307) 251-1701 8/22/14 TFD FP Form 8 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Ur/US / of 1 Type of Inspection: ff � Address:Contact Suite #: /'co5 3 elli A& Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: AG1 Gm-ehS 6-7G� Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: I g'3 Date: Q/2/ /9 Hrs.: fs p $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 1,17'c` l(t7 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Type of Ins ion: �. iQ14/%LL.j2 -'-eviliC Address: tf .te Suite #: / I�5 3"rAvg S Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: - iiRF913(4°R)i.. gewlEord_ Fifjfarc - spc Tr1 Ct'C) K2 6' ,L ret. Pio Needs Shift Inspection: -- Sprinklers: `/rr Fire Alarm: We &- - Date: e9JUANoicr Hood & Duct: -S Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: v \ S? 5Y Date: e9JUANoicr Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 l INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: �l/1 1,6fefr Sprinklers: Fire Alarm: Hood & Duct: Type of I io: ' Pre -Fire: Address: Suite #: - ' .j , Contact Person: Special Instructions: ------- " Phone No.: l L/z © 3Y pproved per applicable codes. Corrections required prior to approval. COMMENTS: 5 pfm k_ NeedsShift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: r Date: / 1 Hrs.: ( $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Word/Inspection Record Form.Doc 3/14/14 Zip: T.F.D. Form F.P. 113 9�9 Hydrau Job Number. 40103 - 40103 Report Description: Residential (1 Job Job Number 40103 Design Engineer Erin Clayton Job Name: Bum Lot 1 Phone 303-551-5308 FAX Address 1 14205 34th Ave S State Cerid¢alAn/Ucense Number Address2 Tukwilla, WA 98168 AHJ Address 3 Job Site/Building System Density 0.05gpm/ft2 Area of Application 900ft2 (Actual 222ft2) Most Demanding Sprinkler Data 4.9 K -Factor 13.00 at 7.039 Hose Streams 0.00 Coverage Per Spnnider 256ft2 Number Of Sprinklers Calculated 2 System Faure Demand 48.371 System Flew Demand 26.30 Total Demand 26.30 @ 48.371 Pressure Result +50.532 (51.1%) uuuup I �. Check Port Gauges Node Name Flow(opmt Hose Flow(gpm) Static(psi) Residual(psi) Identifier Pressure(psi) K-Factor(K) Flow(cipm) 1 Water Supply 985.00 99.000 20.000 40103 Bu I. 1� P Water Supply at Node 1 985.00, 0.00, 99 000 .000) \a ,...,:J.•• r{ 6� !14LlJ 4nn Pressure, psi 3 0 U 01 0) 0 0 CO c 1uuuni1unnui1uuuui1uuuw1uuuw1uuuw1uuwn1unuw1 Static Pressure 99.000 \ 26 30 @ 48.371 1 K System demand curve 85.00 @ 20.000 10 Al 0 =1MMILIllllllIt lllllllll l l l l l l l l l l i l l III I I I I I I I I I 111111111 1 1 1 1 1 1 1 1 1 111111111 9:1600600 800 1000 1200 1400 1600 1800 2000 Water flow, gpm ©M.E.P.CAD, Inc. AutoSPRINK 2018 v14.3.10.0 3/25/2019 11:36:25AM Page 1 Hydraulic Sum ary Job Number. 40103 - 40103 Report Description: Residential (1) Job Job Number. 40103 Design Engineer: Erin Clayton Job Name: Burn Lot 1 State Certl(ralionlLicense Number Address 1 14205 34th Ave S AHJ Address 2 Tukwilla, WA 98168 Job SiteJB lad ng Address 3 Drawing Name 40103_Bum Lot 1_FPP System RemotArea(s) Most Demanding Sprinkler Data 4.9 K -Factor 13.00 at 7.039 Occupancy Residential Job Suffix 40103 Hose ANowance At Source 0.00 Density 0.05gpm/ft2 Area of Application 900ft2 (Actual 222ft2) Additional Hose Supplies Node Flow(aoml Number Of Sprinklers Calculated 2 Coverage Per Sprinkler 256ft2 AutoPeek Rauh. Pressure For Remote Area(s) Adjacent To Most Remote Area Total Hose Streams 0.00 System Flow Demand 26.30 Total water Required (Including Hose Allowance) 26.30 Maximum Pressure Unbalance In Loops 0.000 Maximum Velocity Above Ground 8.86 between nodes 51 and 48 Maximum Velocity Under Ground 0.60 between nodes 1 and 19 Volume capacity of Wet Pipes 384.12gal Volume capecty of Dry Pipes Supplies Node Name Hose Flow (gpm) Static (psi) Residual Flow (psi) @ (gpm) Available Total Demand (psi) @ (gpm) Required (psi) Safety Margin (psi) 1 Water Supply 99.000 20.000 985.00 98.903 26.30 48.371 50.532 contractor Contractor Number Contact Name Contact Tale Name of Contrector: Phone Extension Address 1 FAX Address2 fundi Address 3 Web-ntte © M.E.P.CAD, Inc. AutoSPRINK 2018 v14.3.10.0 3/25/2019 11:36:28AM Page 2 Hydraulic Graph Job Number: 40103 - 40103 • Water Supply at Node 1 A/1 Pressure, psi 0 $ 0 0 0 CO CO C iiiii1 �)1 111 1 11111 ij ,111 1 i1 111111111 111111111 111111111 111111111 co W. w6— co o 0 99.000 @ 48.371 demand IL curve 85.00 @ 20.000 LV 10 miiiiIIIII 1111111 II 111111 I I f I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 I I I I I I I I 0 Q200 400 600 800 1000 1200 1400 Water flow, gpm 1600 1800 2000 Hydraulic Graph Water Supply at Node 1 Static: Pressure 99.000 Residual: Pressure 20.000 @ 985.00 Available Pressure at Time o/ Test 98.903 @ 26.30 System Demand 48.371 @ 26.30 System Demand OndAyip Hex Allowance et Source) 48.371 @ 26.30 © M.E.P.CAD, Inc. AutoSPRINK 2018 v14.3.10.0 3/25/2019 11:36:30AM Page 3 Summary Of''Ouiflowinc, Devices Job Number: 40103 - 40103 Report Description: Residential (1 Device Actual Flow (gpm) Minimum Flow (gpm) K -Factor (K) Pressure (psi) 4' prinkler 202 13.00 13.00 4.9 7.039 Sprinkler 209 13.30 13.00 4.9 7.369 b Most Demanding Sprinkler Data [Aj © M.E.P.CAD, Inc. AutoSPRINK 2018 v14.3.10.0 3/25/2019 11:36:39AM Page 4 111 N6de Anaiyai Job Number: 40103 - 40103 Report Description: Residential (1 Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 1 -3'-0 S 48.371 26.30 202 18'-1 Spr(-7.039) 7.039 13.00 209 18'-1 Spr(-7.369) 7.369 13.30 19 -3'-0 T(8'-0) 48.342 48 16-6 T(5'-0), Tr(1'-0) 7.362 50 13'-111/2 14.901 51 1S-11% 14.901 75 1'-10 BFP(-4.000) 33.538 © M.E.P.CAD, Inc. AutoSPRINK 2018 v14.3.10.0 3/25/2019 11:36:40AM Page 5 Bid Hydraulic Analysis Job Number: 40103 - 40103 Report Description: Residential (1 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Eq. Length Total Length Pressure Summary Downstream Elevation Discharge K -Factor Pt . Pn Fittings Upstream fib Route 1 DR 1.1010 13.00 4.38 150 0.030666 8'-5 8'-0 16-5 Pf 0.503 Pe -0.181 Pv 202 18'-1 13.00 4.9 7.039 Sprinkler, 48 18'-6 7.362 E(7'-0), Tr(1-0) BL 1.1010 26.30 8.86 150 0.112934 28'-4 21'-0 49'4 Pf 5.571 Pe 1.969 Pv 48 18'-6 13.30 7.362 Flow (q) from Route 2 51 13'-111/2 14.901 2T(5'-0), 4Tr(1'-0), E(7'-0) 1.1010 26.30 8.86 150 0.112934 0'-0 0'-0 Pf 0.000 Pe Pv 51 13'-111/2 14.901 50 13'-111/2 14.901 BL 1.1010 26.30 8.86 150 0.112934 53'-01/2 30'-0 83'-01/2 Pf 13.380 Pe 5.257 Pv 50 13'-111/2 14.901 75 1'-10 33.538 2T(5'-0), 6Tr(1'-0), 2E(7'-0), BFP( -4.000) FM 1.5980 26.30 4.21 150 0.018404 112'-2 35'-0 147'-2 Pf 12.709 Pe 2.095 Pv 75 1'-10 33.538 19 -3'-0 48.342 3E(9'-0), WMV(-10.000), T(8'-0) UG 4.2200 26.30 0.60 140 0.000185 157'-10 157'-10 Pf 0.029 Pe -0.000 Pv 19 -3'-0 48.342 1 -3'-0 48.371 S 0.00 Hose Allowance At Source 1 26.30 iiiii Route 2 DR 1.1010 13.30 4.48 150 0.031994 0'-5 5'-0 5'-5 Pf 0.173 Pe -0.181 Pv 209 18'-1 13.30 4.9 7.369 Sprinkler, 48 18'-6 7.362 T(5'-0) Equivalent Pipe Lengths of Valves and Fittings (C=120 only) I C \/ alue Multiplier Actual Inside Diameter 4 87 Value Of C 100 130 140 150 Multiplying Factor 0.713 1.16 1.33 1.51 ( Schedule 40 Steel Pipe Inside Diameter ) = Factor ©M.E.P.CAD, Inc. ifig AutoSPRINK 2018 v14.3.10.0 3/25/2019 11:36:42AM Page 6 Hydraulic Analysi Pipe Type Diameter Flow Job Number. 40103 - 40103 Report Description: Residential (1) Velocity HWC Friction Loss Downstream Upstream Elevation Discharge K -Factor Pt Pn Fittings Length Eq. Length Total Length Pressure Summary Pipe Type Legend Fittings Leg AO Arm -Over BL Branch Line CM Cross Main DN Drain DR Drop DY Dynamic FM Feed Main FR Feed Riser MS Miscellaneous OR Outrigger RN Riser Nipple SP Sprig ST Stand Pipe UG Underground Diameter Elevation Flow Discharge Velocity Pressure Length Friction Loss HWC Pt Pn Pf Pe Pv Inch Foot gpm gpm fps psi Foot psi/Foot Hazen -Williams Constant Total pressure at a point in a pipe Normal pressure at a point in a pipe Pressure loss due to friction between points Pressure due to elevation difference between indicated points Velocity pressure at a point in a pipe ALV AngV b BalV BFP BV C cplg Cr CV DeIV DPV E EE Eel Ee2 fd FDC fE fEE flg FN fT 9 GloV GV Ho Hose HV Hyd LtE mecT Noz P1 P2 PIV PO PRV PrV red S sCV Spr St T Tr U WirF WMV z Alarm Valve Angle Valve Bushing Ball Valve Backflow Preventer Butterfly Valve Cross Flow Turn 90° Coupling Cross Run Check Valve Deluge Valve Dry Pipe Valve 90° Elbow 45° Elbow 11'/.° Elbow 22'/ Elbow Flow Device Flex Drop Fire Department Connection 90° FireLock(TM) Elbow 45° FireLock(TM) Elbow Flange Floating Node FireLock(TM) Tee Gauge Globe Valve Gate Valve Hose Hose Hose Valve Hydrant Long Turn Elbow Mechanical Tee Nozzle Pump In Pump Out Post Indicating Valve Pipe Outlet Pressure Reducing Valve Pressure Relief Valve Reducer/Adapter Supply Swing Check Valve Sprinkler Strainer Tee Flow Tum 90° Tee Run Union Wirsbo Water Meter Valve Cap © M.E.P.CAD, Inc. AutoSPRINK 2018 v14.3.10.0 3/25/2019 11:36:42AM Page 7 t y/1 5* -6 0 bo OWZ,Ter--- DINING FAMILY ROOM KITCHEN 1 gy z 0'-6 10'•0 1 4 r 3'-9'/4 6'-0 50 2'- 1 3/4 ENTRY OPEN TO ABOVE GARAGE OPEN TO ABOVE 63 MAIN LEVEL PLAN MINIMUM DISTANCES FOR TEMPERATURE RESIDENTIAL SP NK ERS HEAT SOURCE 165 DEGREE DENSITY (gpmlft2) 0.05 for 900ft2 (Actual 222ft2) 200 DEGREE 2 K -FACTOR 4.9 TOTAL WATER REQU D 26.30 SIDE OF OPEN OR RECESSED FIRE PLACE 36 In BASE of RISER Wpm) 26.30 12 in FRONT OF RECESSED FIREPLACE 60 In 36 in COAL -OR WOOD BURNING STOVE 42 In _ j i 12 in . WALL OVEN 18 in Quantity 9 in HOT AIR FLUES 18 in 9 in UNINSULATED HEAT DUCTS 181n REC49 F3RES44 DRY 9 in SIDE OF CEILING OR WALL MOUNTED HOT AIR DIFFUSERS 24 In I 12 in FRONT OF WALL MOUNTED HOT AIR DIFFUSERS 36 In PER NFPA 13 9.2.2.1 (A) 18 in HOT WATER HEATER OR FURNACE 6 In 3 in LIGHT FIXTURE , OW -250W 6 in 3 in PER NFPA 13D TABLE 7.55.3 HANGER SPACING LEGEND Rem te Area 1 OCCUPANCY CLASSIFICATION Residential DENSITY (gpmlft2) 0.05 for 900ft2 (Actual 222ft2) TOTAL HEADS FLOWING 2 K -FACTOR 4.9 TOTAL WATER REQU D 26.30 TOTAL PRESSURE REQUIRED 48.371 BASE of RISER Wpm) 26.30 BASE of RISER (psi) 48.371 as Quantity II TS Model REC49 F3RES44 DRY u. ir Manufacturer 23 PER NFPA 13 9.2.2.1 (A) STAND OFF HANGER #10x1" HEX HEAD CAP SCREW COMPOSITE WOOD I -JOIST ARMOVER / DROP \ BEDROOM 3 BEDROOM 3 BEDROOM 2 81-0 PLAYROOM Are Are -4# REMOTE AREA 1 V• Ck4 271 fr DROP UTIL TY 0 41 rer 72,1 • <11 OPEN TO BELOW MASTER 1BEDROOM MEDIA ROOM o 1-0 int wic MASTER BATH 4/0 INSUALTION BY OTHERS VAPOR BARRIER STAPLED // // // / El UPPER LEVEL PLAN BLOWN -IN INSULATION ABOVE BATT INSULATION BY OTHERS BATTTYPE INSULATION — COLD SPACE \ VAPOR BARRIER — SPRINKLER PIPE TRUSS CHORD OR JOIST GYPSUM BOARD CEILING —I GYP. BOARD/ TaG CEILING TJI SPACE N- SEMI-REC. PENDENT SPRINKLER PIPE TENT INSULATION DETAIL #3 PIPE TENT INSULATION DETAIL #2 PIPE SHALL BE REQUIRED TO REMAIN ON A 2.25" CENTERLINE ON THE TOP OF THE sarrom TRUSS CORD ALLOWING FOR TENTING AND SHALL HAVE PRIOR ITY OVER OTHER TRADES. ADEQUATE INSULATION BY OTHERS , SPRAY RIGID 7 FOAM INSULATION / BY OTHERS Rem te Area 1 OCCUPANCY CLASSIFICATION Residential DENSITY (gpmlft2) 0.05 for 900ft2 (Actual 222ft2) TOTAL HEADS FLOWING 2 K -FACTOR 4.9 TOTAL WATER REQU D 26.30 TOTAL PRESSURE REQUIRED 48.371 BASE of RISER Wpm) 26.30 BASE of RISER (psi) 48.371 BEDROOM 3 BEDROOM 3 BEDROOM 2 81-0 PLAYROOM Are Are -4# REMOTE AREA 1 V• Ck4 271 fr DROP UTIL TY 0 41 rer 72,1 • <11 OPEN TO BELOW MASTER 1BEDROOM MEDIA ROOM o 1-0 int wic MASTER BATH 4/0 INSUALTION BY OTHERS VAPOR BARRIER STAPLED // // // / El UPPER LEVEL PLAN BLOWN -IN INSULATION ABOVE BATT INSULATION BY OTHERS BATTTYPE INSULATION — COLD SPACE \ VAPOR BARRIER — SPRINKLER PIPE TRUSS CHORD OR JOIST GYPSUM BOARD CEILING —I GYP. BOARD/ TaG CEILING TJI SPACE N- SEMI-REC. PENDENT SPRINKLER PIPE TENT INSULATION DETAIL #3 PIPE TENT INSULATION DETAIL #2 PIPE SHALL BE REQUIRED TO REMAIN ON A 2.25" CENTERLINE ON THE TOP OF THE sarrom TRUSS CORD ALLOWING FOR TENTING AND SHALL HAVE PRIOR ITY OVER OTHER TRADES. ADEQUATE INSULATION BY OTHERS , SPRAY RIGID 7 FOAM INSULATION / BY OTHERS Temperature '2?‘1--4P4N4i0eliNt40,441p00,40,$*14t _ / • 40 0 141 ta 6 .4A . , 4 ittr 4 . . At t 4. 4 " • .4a4 * 4 , , , \ , , ..„ „: -.:)y,.. \,-,,,,,\ ,,,..! _ NO - BLOCK ' • x . „ , *VA 4114 ' ' 464 •4‘40,44W 1 . 47 P4 r . T. . . . . .41.4"," OE* ii, ,,,b ; 4 2 k. ,.-& ,40,40, NN CPVC PIPE iv aril ia4• . .40 040 ,* #0.1 Ar 4 as Quantity PIPE TENT INSULATION DETAIL 1 SCALE N.Ts. ipatuesse 111111111111111100111111.041111111111111 411111111111101111111 a WASHINGTON STATE ▪ CERTIFICATE OF COMPETENCY g FIRE PROTECTION SPRINKLER SYSTEM • Erin Clayton I 7644-0817-C Level 3 ▪ Glacier Fire Protection, L.L.C. 03/2 MIN $161441111111111111144 lag .44,160....... j 12/31119 I MOM IMMO el d Sprinkler Legend Temperature Response Quick a Quick ui ca as Quantity II TS Model REC49 F3RES44 DRY u. ir Manufacturer 23 NORTH GLACIER FIRE PROTECTION LLC PO BOX 7980 BONNEY LAKE, WA 98391 PARCEL # 116 CO O- w CO 6 SCALE: 114"= DRAWN BY: SFC REVISIONS NO, DESCRIPTION DATE: 03 9 CONT CT :40103 FLOOR / AREA MAIN AND UPPER LEVEL PLAN SHEET NUMBER FP 2.10 2 012