Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 14217 34TH AVE S - BURN LOT 3 - PERMITS AND PLANS
14217 34TH AVE S ASSOCIATED PERMITS 19-S-095 D18-0382 0 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 553720-0114 Site Address: Burn Lot 3 - 14217 34th Avenue S Suite Number: Floor: Tenant Name: (new construction) New Tenant? ❑ - Yes E - No Property Owner's Name: Cary Lang Construction Mailing Address: 29815 24th Ave SW Federal Way WA 98023 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Jake Box Day Telephone: (307) 251-1701 Company Name: Glacier Fire Protection, LLC Mailing Address: PO Box 7980 Bonney Lake WA 98391 jakeb@glacierfp.com City State Zip E-mail Address: Fax Number: N/A NICET III number: Erin Clayton 7544-0817-C Contractor's Citys License number: of Tukwila 0998044 Busine Total number of new/relocated devices or sprinkler heads: 32 Valuation of Project (contractor's bid price): $ 7,700.00 Scope of Work (please provide detailed information): Design & install fire sprinkler system in new constructed 1 family dwelling per NFPA 13D. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WAU{INGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. PAU-) BUILDING OWNER OR AUTHORIZED AGENT: gip? '- 0 2 1 4/22/2019 Jake Box - Signature: °"'�°'s�,.0"r TUKWILA FIRE Date: Print Name: Jake Box Day Telephone: (307) 251-1701 Plan Permit App.doc 8/22/14 TFD FP Form 8 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: (jCcc, .rhe, U,� w y Type of Inspection: ,4.te. - frij Address:,,Contact Suite #: / Z/7 3cfr ✓k S Person: 571" Permits: Special Instructions: A Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 3Fai All<t-ge_ IZAIL 19-rpo-oveD e 3(0 ste- Needs Shift Inspection: Sprinklers: ygg' Fire Alarm: cg '"---- Hood & Duct: A-6 Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Date: i 11t4 1 n Hrs.: l $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 ( INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: �� CGS- Sprinklers: Fire Alarm: Hood & Duct: Type of Inspection: c�� Address: Suite #: (4L l AA_ `�Ary � 5 Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 6 k_ Cer-12_ Fly z f'6,(0)(k) 0L, Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: l Inspector: 1— 51,_ Date: ),//, n Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 . `. J - S- oq Hydraulic Overview Job Number: 40109 - 40109 Report Description: Residential (1 ©M.E.P.CAD, Inc. 111 AutoSPRINK 2018 v14.3.10.0 4/22/2019 1:38:49PM Page 1 Job Number 40109 Design Engineer Erin Clayton Job Name: Burn Lot 3 Phone 303-551-5308 FAX Address 1 14217 34th Ave South State Certification/License Number Address 2 Tukwilla, WA 98168 AHJ Address 3 Job Slte/Building System ,. Densly 0.05gpm/ft2 Arca of Application 900ft° (Actual 272ft2) Most Demanding Spnnlder Data 4.9 K -Factor 13.00 at 7.039 Hose Streams 0.00 Coverage Per Spnnlder 256ftg Number Of Spnnlders Calculated 2 System Pressure Depend 52.294 Syeem Pipet °emend 26.30 Total Demand 26.30 @ 52.294 Pressure Result +46.610 (47.1%) supps Check PoinaUges' Node Name Flow(gpm) Hose Flow(qpm) Static(psil Residual(psi) Identifier Pressure(psil K-Factor(K) Flow(qpm) 3 Water Supply 985.00 99.000 20.000 46109 8 M Lot 3_FPF ;, - Water Supply at Node 3 (985.00, 0.00, 99 000, 20.000) AAA Pressure, psi i o 8 S 0)0 0 0 03 0 C 1uuiini1ninun1uwnn1nunw1nuuw1inuuu1inuuu1uuuni Static Pressure 99.000 26 30 @ 52.294 \ A 41 / System demand curve 85.00 @ 20.000 10 0 INIII111111111IIIIIIIIIIIIIIIIIII111 III 111111111 111111111 111111111 111111111 pdF0600 800 1000 1200 1400 1600 1800 2000 Water flow, gpm ©M.E.P.CAD, Inc. 111 AutoSPRINK 2018 v14.3.10.0 4/22/2019 1:38:49PM Page 1 Hydraulic Summary Job Number: 40109 - 40109 Report Description: Residential (1 Job Job Number 40109 Design Engineer Erin Clayton Job Name Burn Lot 3 State Cedificationlicense Number Address 1 14217 34th Ave South AHJ Address 2 Tukwilla, WA 98168 Job Site/Bulling Address 3 Drawing Name 40109_Burn Lot 3_FPP Remote Ar (s) Most Demanding Sprinkler Data 4.9 K -Factor 13.00 at 7.039 Occupancy Residential Job Suffix 40109 Hose Allowance At Source 0.00 Density 0.05gpm/ft2 Area of Applk:ation 900ft2 (Actual 272ft2) Additional Hose Supplies Node Flow(gpm) Number Of Spnnklers Calculated 2 Coverage Per Sprinkler 256ft2 AutoPeak Results: Pressure For Remote Area(s) Adjacent To Most Reno ekes Left: 52.294 Right: 52.294 Total Hose Streams 0.00 System Flow Demand 26.30 Total Kbter Required (Including Hose Allowance) 26.30 Maximum Pressure Unbalance In Loops 0.000 Maximum Velocity Above Ground 8.86 between nodes 2 and 1 Maximum Velocity Under Ground Volume capacity of let Pipes 972.47ga1 Volume capacity of Dry Pipes Supplies � .. Node Name Hose Flow (gpm) Static (psi) Residual Flow (psi) @ (gpm) Available Total Demand (psi) @ (gpm) Required (psi) Safety Margin (psi) 3 Water Supply 99.000 20.000 985.00 98.903 26.30 52.294 46.610 Contractor Contractor Number Contact Name Contact Tile Name of Contractor. Phone Extension Address 1 FAX Address 2 E-mail Address 3 1ebSlte M.E.P.CAD, Inc. AutoSPRINK 2018 v14.3.10.0 4/22/2019 1:38:52PM Page 2 a• Hydraulic Groh Job Number: 40109 - 40109 1 /v1 Water Supply at Node 3 Pressure, psi D o $ o 0 o CO `8 C 11111 11`N1111111 1,1 111111 111111111, N rn �_ w m o ii R....... Pressure 99.000 @ 52.294 demand curve • 85.00 @ 20.000 LV 10 0 • 111 111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I I I I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I I I I I I I I I I I I I I I I I I I I I I I I I 1 I I I I I I I I 0200 400 600 800 1000 1200 1400 Water flow, gpm 1600 1800 2000 Hydraulk G aph Water Supply at Node 3 Static: Pressure 99.000 Residual: Pressure 20.000 @ 985.00 Available Pressure at Tome of Test 98.903 @ 26.30 System Demand 52.294 @ 26.30 System Demand (Including Hou Allowance at Soule) 52.294 @ 26.30 L ©M. E. P. CAD, Inc. 4,1 AutoSPRINK 2018 v14.3.10.0 4/22/2019 1:38:54PM Page 3 Summary Of Outflowing Devices Device Actual Flow (gpm) Minimum Flow (gpm) Job Number: 40109 - 40109 Report Description: Residential (1) K -Factor (K) Pressure (Psi) b Sprinkler 101 13.00 13.00 4.9 7.039 Sprinkler 102 13.30 13.00 4.9 7.369 c> Most Demanding Sprinkler Data �A © M.E.P.CAD, Inc. AutoSPR I N K 2018 v14.3.10.0 4/22/2019 1:39:04PM Page 4 Node Analysis Job Number: 40109 - 40109 Report Description: Residential (1 Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 3 -3'-0 S 52.294 26.30 101 18'-1 Spr(-7.039) 7.039 13.00 102 18'-1 Spr(-7.369) 7.369 13.30 1 18'-6 T(5'-0), Tr(1'-0) 7.362 2 1'-10 BFP(-4.000) 38.240 [y © M.E.P.CAD, Inc. AutoSPRINK 2018 v14.3.10.0 4/22/2019 1:39:10PM Page 5 I9 Hydraulic Ai ysis Job Number: 40109 - 40109 Report Description: Residential (1 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Eq. Length Summary Total Length Downstream Elevation Discharge Upstream K -Factor Pt Pn Fittings =► Route 1 DR 1.1010 13.00 4.38 150 0.030666 8'-5 8'-0 16'-5 Pf 0.503 Pe -0.181 Pv 101 18'-1 13.00 1 18'-6 4.9 7.039 7.362 Sprinkler, E(7'-0) Tr(1'-0) BL 1.1010 26.30 8.86 150 0.112934 106'-0'% 68'-0 174'-0'% Pf 23.653 Pe 7.225 Pv 1 18'-6 13.30 2 1'-10 7.362 38.240 Flow (q) from Route 2 13Tr(1'-0), 4T(5'-0), 5E(7'-0), BFP(-4.000) BL 1.5980 26.30 4.21 150 0.018404 97'-5 9'-0 106'-5 Pf 11.958 Pe 2.095 Pv 2 1'-10 3 -3'-0 38.240 52.294 E(9'-0), WMV(-10.000), S 0.00 Hose Allowance At Source 3 26.30 Gib Route 2 DR 1.1010 13.30 4.48 150 0.031994 0'-5 5-0 5'-5 Pf 0.173 Pe -0.181 Pv 102 18'-1 13.30 1 18'-6 4.9 7.369 7.362 Sprinkler, T(5'-0) Equivalent Pipe Lengths of Valves and Fittings (C=1 !,only) C Vater Multiplier Actual Inside Diameter 4.87 = Factor Value Of C 100 Multiplying Factor 0.713 130 140 150 1.16 1.33 1.51 ( Schedule 40 Steel Pipe Inside Diameter ) ©M.E.P.CAD, Inc. AutoSPRINK 2018 v14.3.10.0 4/22/2019 1:39:16PM Page 6 Hydra lic Analysis Job Number: 40109 - 40109 Report Description: Residential (1) Pipe Type Diameter Flow Velocity HWC Friction Loss Downstream Upstream Elevation Discharge K -Factor Pt Pn Fittings Length Eq. Length Total Length Pressure Summary Pipe Type Legend tins Legend Fittings Legend AO Arm -Over BL Branch Line CM Cross Main DN Drain DR Drop DY Dynamic FM Feed Main FR Feed Riser MS Miscellaneous OR Outrigger RN Riser Nipple SP Sprig ST Stand Pipe UG Underground Diameter Elevation Flow Discharge Velocity Pressure Length Friction Loss HWC Pt Pn Pf Pe Pv Inch Foot gpm gpm fps psi Foot psi/Foot Hazen -Williams Constant Total pressure at a point in a pipe Normal pressure at a point in a pipe Pressure loss due to friction between points Pressure due to elevation difference between indicated points Velocity pressure at a point in a pipe ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 11W Elbow Ee2 22W Elbow Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap /�+ © M.E.P.CAD, Inc. AutoSPRINK 2018 v14.3.10.0 4/22/2019 1:39:16PM Page 7 SITE PLAN 4 8 16 32 SCALE 1/16"=1'-0" GENERAL NOTES SCOPE OF WORK ❑ Without Comments As Noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire revention Bureau fig conformance with current City :ndards. Acceptant. is subject to en -ors and omissions which do t: urhor ize violations of adopted standards and orcir:anc.The resrnslolflcy for the juequacy of design , .rr r' taliv; with the designer, ditaons, delebov* c, to those drawings after his date will void thy.:- sc eptance and wi ( require a resubmittal of ro 1 . drawings for stib,c.gi nt: approval. Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: I LI `i By: 4-1/v1 Y d,0 Iti&-,w.,(. r•iLiK {fly: FIRE DEPARTMENT DEPAR lMENT PiGsa f-111206-575.4407 and give this Fire Permit No. and exact address for shut- down or restoration approval. CPVC PIPE STRAP I / AFCON MODEL 510 CPVC PIPE% HEX HEAD SELF TAPPING SCREW AFCON #905 f DOUBLE FASTENER CPVC PIPE STRAP TYPICAL HANGER DETAIL #1 SCALE : N.T.S. / PROPERTY LINE • EW 1 112' CITY CONNECTION BY OTHERS NEW 1" WATER METER BY OTHERS NN ti HUlos any RIVE WOOD LAG SCREW PROPERTY LINE GLACIER FIRE PROTECTION, LLC TO START AT 1 112' BACKFLOW C1'-10" AFF AFCON #514 HANGER 20V6" BELL CPVC SPRINKLER PIPE WOOD STRUCTURE TYPICAL HANGER DETAIL #2 SCALE : N.T.S. 'HANGER APPLICATION N. RESTRAINER APPLICATION HEX HEAD SELF TAPPING SCREW CPVC PIPE SINGLE FASTENER CPVC PIPE STRAP TYPICAL HANGER DETAIL #3 SCALE : N.T.S. 1. THE FIRE PROTECTION SPRINKLER SYSTEM FOR THE SINGLE FAMILY DWELLING UNIT SHALL BE DESIGNED AND INSTALLED PER NFPA 13D, 2013. 2. CALCULATION FOR THE RESIDENCE SHALL BE PER NFPA 13D, 2013. 3. PIPE THROUGHOUT THE DWELLING UNIT TO BE CPVC SPRINKLER PIPING UNLESS NOTED OTHERWISE. 4. ALL HANGERS SHALL BE PLACED AND INSTALLED IN ACCORDANCE WITH NFPA 13, 2013. 5. SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 SQ.FT. AND LESS. 6. SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES THATARE LESS THEN 24 SQ.FT., THE LEAST DIMENSION DOES NOT EXCEED 3'-0 AND THE ROOM IS SURFACED WITH NONCOMBUSTIBLE OR LIMITED COMBUSTIBLE MATERIALS. 7. SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES, OPEN ATTACHED PORCHES, CARPORTS, AND SIMILAR STRUCTURES. 8. SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS, CONCEALED SPACES, FLOOR/CEILING SPACES, CRAWL SPACES, AND OTHER CONCEALED SPACES THATARE NOT USED OR INTENDED FOR LIVING PURPOSES AND DO NOT CONTAIN FUEL -FIRED EQUIPMENT. 9. WIRING OF ANY NEW DEVICES IF REQUIRED IS BY OTHERS. 10. PAINTING AND LABELING OF PIPING IF REQUIRED IS BY OTHERS. FIRE SPRINKLERS SHALL NOT BE PAINTED OVER. 11. IT SHALL BE THE OWNERS RESPONSIBILITY TO MAINTAIN THE TEMPERATURE ABOVE 400 AT ALL TIMES. 12. A MAIN DRAIN IS TO BE PROVIDED AND INSTALLED IN ACCORDANCE WITH NFPA-13D. HUB DRAINS TO BE PROVIDED BY OTHERS AS NEEDED. 13. NO GYP. BD. CEILINGS SHALL BE INSTALLED UNTIL ROUGH VISUAL INSPECTION IS COMPLETE. 14. MAXIMUM RESIDENTIAL PENDANT SPRINKLER SPACING COVERAGE 16'-0 x 16'-0. MAXIMUM DRY SIDEWALL SPRINKLER HEAD SPACING 14'-0 X 14'-0. MAXIMUM RESIDENTIAL DRY SIDEWALL SPRINKLER HEAD SPACING 16'-0 X 20'-0. 15. MINIMUM RESIDENTIAL PENDANT SPRINKLER SPACING 8'-0 O.C. MINIMUM DRY SIDEWALL SPRINKLER SPACING 6'-0 O.C. MINIMUM RESIDENTIAL DRY SIDEWALL SPRINKLER SPACING 8'-0 O.C. 16. ALL VALVES TO BE LABELED IN ACCORDANCE WITH NFPA-13D. 17. PIPE SHALL BE REQUIRED TO REMAIN ON A 2.25" CENTERLINE ON THE TOP OF THE BOTTOM TRUSS CORD ALLOWING FOR TENTING AND SHALL HAVE PRIORITY OVER OTHER TRADES. FIRE SPRINKLER RISER WATER GAUGE 1" DRAIN - FLOW SIMTCH DOMESTIC LINE BY OTHERS GLACIER FIRE PROTECTION, LLC TO START WORK HERE 1112" AMES'2t00B BACKFLOW PREVENTOR PROVIDED AND INSTALLED BY GLACIER FIRE PROTECTION, LLC 1 112" WATER ENTRY BY OTHERS MAINTAIN 2" MNULAR __J CLEARANCE AROUND PIPE 4217 34th Ave S rrf.E a dest;.ri on foryour trap:. GLACIER FIRE PROTECTION WILL PROVIDE ONE WET PIPE AUTOMATIC SPRINKLER SYSTEM TO PROTECT THE NEW RESIDENCE. EXCLUSIONS PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT ELECTRICAL WIRING OF ANY KIND INCLUDING BUT NOT LIMITED TO WATERFLOW SWITCH, ELECTRIC BELL, AND TAMPER SWITCHES CENTRAL STATION MONITORING EQUIPMENT, WIRING AND SERVICES CEILING AND WALL REMOVAL/REPLACE TO FACILITATE THE INSTALLATION OF THE SPRINKLER SYSTEM. UNDERGROUND WORK OF ANY KIND DESIGN CRITERIA PER NFPA 13D (2016) RM -01 (RESIDENCE) THE DENSITY SHALL BE 13 GPM/SF OVER THE MOST REMOTE 2 SPRINKLERS WITHIN A COMPARTMENT. 16'-0x 16'-0 MAX SPACING WATER FLOW INFORMATION WATER FLOW INFORMATION HAS BEEN PROVIDED BYTUKWILLA PUBLIC WORKS DEPARTMENT STATIC: 99 PSI RESIDUAL: 20 PSI FLOW: 985 GPM DRAWING INDEX FP 0:10 SITE PLAN AND NOTES FP 2.10 MAIN AND UPPER LEVEL PLAN learatarrana staiesese we nom WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEM Erin Clayton 7544.0817.0 Level 3 Glacier Fire Protection, L.L.C. GLACIFP834MJ CU- 04/2212019 II 12f31f19lii --e r«I N tr¢_ mw a- r1•.6 Sprinkler Legend Temperature � o If) h e- LL 0 If) e- e- U. 0 N .- N .c w U- tv E U y S d- y7 Response Quick Quick 0 d 0) N CO r w I --a. T6 2 cn Pendent 5' d m o. " c3 03U. v 0) 5.8 F 29 `- Total = 32 5 0 2 F3RES44 DRY RFC49 RFC 58 Z U) r N 2 CO o 2 CO 0 2 Manufacturer d 27) m cc 0 m cc Reliable Symbol 1 NORTH GLACIER FIRE PROTECTION LLC PO BOX 7980 BONNEY LAKE, WA 98391 P: (253) 501-7558 www.glacierfireprotection.com GLACIFP834MJ PARCEL #553720-0114 VICINITY DESCRIPTION APR : 0 2019 UK ,,af ILA Fl c, c "„e3 8'-0 S 447 GREAT ROOM • 1 ! 2'-9 '_ei ws• 1 4cu ku. '41% 4'-8% 40 DINING ROOM 101-0 KITCHEN I LI "'V:%/ 6' STUDY t)ke'fr IS/ 81-0 3/4 BATH N. 41' // _ r/ATA7E/ iffEk 7,-9 1'. 31-514 7,3 4 2:1 -,I 'NEZMXI ARMOVER/DROP GARAGE DROP DETAILS SCALM:14.T.S. MAIN LEVEL PLAN SCALE :1/4" = V-0 .4117/2" P1 0 PIPE SHALL BE REQUIRED TO REMAIN ON A 225" CENTERLINE ON THE TOP OF THE BOTTOM TRUSS CORD ALLOWING FOR TENTING AND SHALL HAVE PRIORITY OVER OTHER TRADES. ADEQUATE INSULATION BY OTHERS STAND OFF HANGER #10x1" HEX HEAD CAP SCREW COMPOSITE WOOD I -JOIST rzyzy :„.,/zsyzff 4'.1 cb 1 4i0 ( ori. VA tt3 1 MSTR BDRM g re, n tree, ow tre MSTR BATH -9 •-• ,fdif/ASIPZ /AY -=40249' /AV -s. BDRM 2 It /4WASAfer.497/ ZAVASZOWAVAir 2'- DRM 3 , 4%0% / as / ) (Th 8* -0 • 2'4‘ 8* -0 t.; VA REMOTE AREA 1 BDRM 4 PLAY R 6'40% .4GY '7.41r/ff' !/< UPPER LEVEL PLAN SCALE : 1/4" = 1'4) INSUALTION BY OTHERS VAPOR BARRIER.. STAPLED - GYP. BOARD/ T&G CEILING TJI SPACE SEMI-REC. PENDENT SPRINKLER PIPE TENT INSULATION DETAIL #3 SCALE : N.T.S. / MINIMUM DISTANCES FOR TEMPERATURE RESIDENTIAL SPRINKLERS 1 HEAT SOURCE 3/4" 165 DEGREE I 1 200 DEGREE 2 1/2" 3" 4" ! I STEEL PIPE SCH 40, SCH 10, DF,EF SIDE OF OPEN OR RECESSED FIRE PLACE 12-0 36 In i 1 12 In FRONT OF RECESSED FIREPLACE 15-0 60 in . 1 i 36 In COAL -OR WOOD BURNING STOVE 12-0 42 in 18 in 1 1 :9 1 I 12 in KITCHEN RANGE in WALL OVEN I 18 in . 10-0 9 In HOT AIR FLUES I 18 m I 15-0 9 in UNINSULATED HEAT DUCTS Manufacturer 181n 12 in .2 .0 .II It 7-0 9 in UNINSULATED HOT WATER PIPES 10-0 6 in SIDE OF CEILING OR WALL MOUNTED HOT AIR DIFFUSERS _ N/A 24 In I I 12 in FRONT OF WALL MOUNTED HOT AIR DIFFUSERS ! 36 in Gin I I I I 18In 3 in HOT WATER HEATER OR FURNACE LIGHT FIXTURE OW -250W Gm i I 3 in PER NFPA 130 TABLE 7.6.6.3 HANGER SPACING LEGEND NOMINAL PIPE SIZE (IN.) 3/4" 1" 1 1/4" . 1 1/2" 2" 2 1/2" 3" 4" 50 26.30 STEEL PIPE SCH 40, SCH 10, DF,EF N/A 12-0 12-0 15-0 15-0 SAFETY MARGIN (psi) 15-0 15-0 15-0 15-0 THREADED LIGHTVVALL N/A 12-0 12-0 12-0 12-0 12-0 N/A N/A N/A N/A COPPER tv tv) II i-- Model 1 10-0 10-0 12-0 12-0 12-0 15-0 15-0 15-0 CPVC Manufacturer al 76 A tt .2 .0 .II It 7-0 8-0 ..... 10-0 N/A N/A _ N/A PER NFPA 13 9.2.2.1 (A) BLOWN -IN INSULATION ABOVE BATT INSULATION BY OTHERS BATTTYPE INSULATION — COLD SPACE / / / /// bc)aPc7jUZPLUS) Hydraulic Information Remote Area 1 OCCUPANCY CLASSIFICATION Residential DENSITY (gpm/ft2) 0.05 for 900ft2 (Actual 272ft2) TOTAL HEADS FLOWING 2 K -FACTOR 4.9 TOTAL ATER REQUIRED 26.30 TOTAL PRESSURE REQUIRED 52.294 BASE of RISER (ctprn) 26.30 BASE of RISER (psi) 52.294 SAFETY MARGIN (psi) +46.610 (47.1%) — SPRINKLER PIPE VAPO BARRI R TRUSS CHORD OR JOIST GYPSUM BOARD CEILING PIPE TENT INSULATION DETAIL: SCALE : SPRAY RIGID / FOAM INSULATION / BY OTHERS I I I i 1 I 1 I II I I I I IL. a Li) EL v 1.n 1------I '''Aak.): . j,,, [1 rr:K.,1 -;:.,/i': . . , 4' \ , ' * ,...111. 44:14,741k•ilfs _ %•*":11:olKSFA-:4:474i . . I 04.400* 0 * Si; : NN CPVC PIPE --"--- ,1):: ./..';‘.4kriA;;VI \P:..:•41411°/ • "te 4 •411444 ' 4, TJI JOIST Response Quick I Quick Quick 0) C)) PIPE TENT INSULATION DETAIL 1 SCALE : NTS. itermateatassesuinamsousenamaasseininammosasis II WASHINGTON STATE i 1 1 CERTIFICATE OF COMPETENCY s II FIRE PROTECTION SPRINKLER SYSTEM i . i Erin Clayton • 7544-0817.0 Level ' g Glacier Fire Protection, L.L.C. • GLACIFP834MJ Ii 2 04122/2019 trOS 8 s SIgnatura Ilhassionioutimattamemeammossorautoomors Sprinkler Legend Temperature IL. a Li) EL v 1.n LL * iNi C in ......•-• a.... .... LLQ i...4) c a 0... ,,e :- ,e CD Response Quick I Quick Quick 0) C)) z --*'se e TS CIL .2) TS O. 0 01 11. ' (14 Quantity tv tv) II i-- Model 1 F3RES44 DRY u. et Manufacturer al 76 A tt .2 .0 .II It 2 Ja. ..% It ..... NORTH GLACIER FIRE PROTECTION LLC PO BOX 7980 BONNEY LAKE, WA 98391 P: (253) 501-7558 www.gladeifireprotection.win GIACIFP834MJ PARCEL # 553720-0114 8 10 12 SCALE: 1/4" =1,-0" DRAWN BY: SFC REVISIONS NO. DESCRIPTION DATE: /22/19 CONTRACT #:40109 FLOOR /AREA MAIN AND UPPER LEVEL SHEET NUMBER FP 2.10 2 of 2