PP - 12611 37TH AVE S - RAD RESIDENCE - PERMITS AND PLANS
12611 37TH AVE S ASSOCIATED PERMITS 17-S-091 D16-0269 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Site Address: 12611 37TH AVE S **PLEASE PRINT** King Co. Assessor's Tax No.: 7345600812 Suite Number: Floor: Tenant Name: New Tenant? ❑ - Yes ❑ - No Property Owner's Name: BALZARINI, THOMAS J Mailing Address: 12611 37TH AVE S TUWKILA City WA, 98168 State Zip CONTACT PERSON -if there are questions about the submittal. Name: KYLE WHITT Day Telephone: 253-840-9900 Company Name: RED HAWK FIRE PROTECTION Mailing Address: 801 VALLEY AVE SUITE D PUYALLUP WA 98371 KYLEW@REDHAWKFP.COM City State Zip E-mail Address: Fax Number: 800-591-4382 Contractor's City of Tukwila NICET III number: Business License number: REDHAHF901 QP Total number of new/relocated devices or sprinlder heads: 16 Valuation of Project (contractor's bid price): $ 5417 Scope of Work (please provide detailed information): INTALL NEW NFPA 13D FIRE SPRINKLER SYSTEM IN NEW SINGLE FAMILY RESIDENCE PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 5/16/17 Print Name: RED HAWK FIRE PROTECTION Day Telephone: 253-840-9900 Plan Permit App.doc 8/22/14 TFD FP Form 8 Z INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: lb (15 Sprinklers: Type of Inspection: 5 tvte--- rditi-Z--- Address: rn- Suite #: t k, (1 S Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: g-1,---7--- 7 57 ell) --S /\%6---b e / 7 S 4t,( frw 3d. 9 -SI- Zit) 1i- t4s. j-` /7 13J F —"r f✓ npp/2 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: hilr, 21i Date: f/Z 2tll r IHrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: '- Z�X�LC N � Type of In pecti�on• >i�r�y'/ Suite #: Address:, Address:3% ��i / Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. )'Corrections required prior to approval. COMMENTS: (.�/Y/w fo 6.0-i/✓ya/Idat Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: ` le, / 4 Date: 6/101 / { Hrs.: i- 0 • $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.E.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:- r-ko g_ritof)J cr Type of Insp ction: crire-g_ ,,-(k lotto / 6 1/4,k_&-- Address:Contact Suite #: /2411 371---44- 5 Pe son: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: rP 616 c.nvEl -7r,4 mJD 1-tr---4-10 seyt-c„,../ 62 6 ic._ Pre -Fire: flyo& ()k- / 60 (si fan- 2'Y2S Occupancy Type: 13 -774c -E-7- frr?-T--. Fke /1, /N7E-E1D-E-b 77- 4i-1- 12-. 30 3E -c, F 2 tis r— 47 /6 s' c A)D g vi tiO> i -J6 PEil2A4A_ tr---- dniNi S 7 Ft Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 4-74y1 51+ Date: 6,/L.'rq___ Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Hydraulic Calculations for Project Name: RAD RESIDENCE Location: 12611 37TH AVE SOUTH, , TUKWILA, WA, 98168 Drawing Name: 80082_FLOORPLANS Design Remote Area Number: 01 KITCHEN/DINING Remote Area Location: KITCHEN/DINING Occupancy Classification: Residential 18X18 Commodity Classification: HOUSE 13D Density: 0.050gpm/ft2 Area of Application: 900.00ft2 (Actual 352.38ft2) Coverage per Sprinkler: 324.00ft2 Type of sprinklers calculated: Pendent No. of sprinklers calculated: 2 Type of System: In -rack Demand: Hose Streams: Calculation Date: 5/16/2017 WET - CPVC Volume of Dry or PreAction System: N/A gpm at Node: N/A 0.0 gpm at Node: 1 Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 34.30 @ 61.827 Water Supply Information: Name of Contractor: RED HAWK FIRE PROTECTION LLC. Address: 801 VALLEY AVE SUITE D, PUYALLUP, WA, 98371 Phone Number: 253-840-9900 Name of designer: KYLE WHITT Authority Having Jurisdiction: CITY OF TUKWILA Notes: Automatic peaking results Left: N/A Right: N/A N/A 5 WASHINGTON STATE CERTIFICATE OP COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Byron Richard Moye 9419-0815-C Red Hawk Fire Protection, L.L.C. REDHAHFQP g &,© M.E.P.CAD, Inc. �,i` `AutoSPRINK®12 v12.0.54.0 01 KITCHEN/DIP 5/16/2017 4:28:40PM Page 1 Hydraulic Graph Date: 5/16/2017 an z 0 z_ Z ❑ z W W FU-- U W c W ❑ ai E z 0 Remote Area Number: 01 Water Supply Summary Sheet Node: 1 0 0 0 N Tt 0 O O O - - _ - _ - System demand curve II I I vailable Supply Static Pressure 11 4.30 118.988 34.30i61.827 ri 111111111 o 11111111/ 111111111 o in 111111111 111111u 1 o inoV IIIIU Iir IIIIIIIII IIIIITTTT- IIIIIIIII o LOC IIIIIit1I isd - amssaJd 5/16/2017 4:28:42PM AutoSPRINK® 12 v12.0.54.0 ,© M.E.P.CAD, Inc. Summary Of Outflowing Devices Job Number: 80082 Report Description: Residential 18X18 (01 KITCHEN/DINING) Device Actual Flow (gpm) Minimum Flow (gpm) K -Factor (K) Pressure (psi) Sprinkler 'c Sprinkler 1001 1002 17.30 17.00 b Most Demanding Sprinkler Data 17.00 17.00 4.9 4.9 12.459 12.037 f © M.E.P.CAD, Inc. . AutoSPRINK® 12 v12.0.54.0 5/16/2017 4:28:43PM Page 4 Job Name: RAD RESIDENCE 'Remote Area Number: 01 KITCHEN/DINING Date: 5/16/2017 Supply Analysis Node Name Static (psi) Residual Flow (psi) co (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) 1 Water Supply 119.000 42.000 4000.00 118.988 34.30 61.827 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1 -3-0 Supply 61.827 34.30 1001 8-0 Sprinkler 12.459 17.30 1002 8-0 Sprinkler 12.037 17.00 2 0-6 29.916 3 1-11 29.249 4 3-1 22.599 5 5-2% 21.658 101 8-6 12.480 102 8-6 12.528 103 8-6 15.100 (�A © M.E.P.CAD, Inc. hfiAutoSPRINK® 12 v12.0.54.0 5/16/2017 4:28:44PM Page 5 Job Name: RAD RESIDENCE Remote Area Number: 01 KITCHEN/DINING Date: 5/16/2017 Pipe Information Node 1 Elev 1 (Foot) K -Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. Fitting (Foot) Pf Friction Loss Per Unit (Psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow tQ) Actual ID Total (Foot) Friction(Pf) 1002 8-0 4.9 17.00 1 (See Notes) 1-1 150 12.037 Route 1 Sprinkler, E(7-0), T(5-0) 12-0 0.050373 -0.217 101 8-6 17.00 1.1010 13-1 0.660 101 8-6 1 (See Notes) 8-8 150 12.480 T(5-0) Tr(1-0) 6-0 0.003290 102 8-6 3.89 1.1010 14-8 0.048 102 8-6 17.30 1 (See Notes) 21-0 150 12.528 Flow (q) from Route 2 E(7-0), Tr(1-0), T(5-0) 13-0 0.075686 103 8-6 21.18 1.1010 34-0 2.572 103 8-6 13.11 1 (See Notes) 15-9'% 150 15.100 Flow (q) from Route 3 Tr(1-0), 2T(5-0), cplg(1-0) 12-0 0.184525 1.430 5 5-2% 34.30 1.1010 27-9% 5.128 5 5-2% 2 (See Notes) 2-11/2 120 21.658 2f(-0.000) 0.009514 0.921 4 3-1 34.30 2.2030 2-1% 0.020 4 3-1 11/2 (See Notes) 1-2 120 22.599 BFP(-6.100) 0.043813 0.500 3 1-11 34.30 1.6100 1-2 6.150 3 1-11 1'/2 (See Notes) 0-71/2 150 29.249 cplg(1-0), BOR@NODE2 1-0 0.030070 0.618 2 0-6 34.30 1.5980 1-7% 0.049 2 0-6 1 (See Notes) 103-6 150 29.916 E(7-0), WMV(-10.000), S 7-0 0.184525 1.517 1 -3-0 34.30 1.1010 110-6 30.393 0.00 61.827 Hose Allowance At Source Total(Pt) Route 1 1 34.30 1001 8-0 4.9 17.30 1 (See Notes) 0-6 150 12.459 Route 2 Sprinkler, T(5-0) 5-0 0.052005 -0.217 102 8-6 17.30 1.1010 5-6 0 286 12.528 Total(Pt) Route 2 101 8-6 1 (See Notes) 48-11/2 150 12.480 Route 3 3Tr(1-0), 4E(7-0), T(5-0) 36-0 0.031151 103 8-6 13.11 1.1010 84-1'/2 2.620 M.E.P.CAD, Inc. AutoSPRINK® 12 v12.0.54.0 01 KITCHEN/DINING 5/16/2017 4:28:46PM Page 6 Job Name: RAD RESIDENCE Remote Area Number: 01 KITCHEN/DINING Date: 5/16/2017 Pipe Information Node 1 Elev 1 (Foot) K -Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. Fitting (Foot) Pf Friction Loss Per Unit (Psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 15.100 Total(Pt) Route 3 © M.E.P.CAD, Inc.AutoSPRINK® 12 v12.0.54.0 01 KITCHEN/DINING 5/16/2017 4:28:46PM Page 7 Job Name: RAD RESIDENCE Remote Area Number: 01 KITCHEN/DINING Date: 5/16/2017 [Equivalent Pipe Lengths of Valves and Fittings (C=120 only) ` [C Value Multiplier Actual Inside Diameter N 4.87 = Factor Schedule 40 Steel Pipe Inside Diameter Value Of C 100 130 140 150 Multiplying Factor 0.713 1.16 1.33 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DeiV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 111/4° Elbow Ee2 22W Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Tum Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Tum 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap • © M.E.P.CAD, Inc. AutoSPRINK® 12 v12.0.54.0 01 KITCHEN/DINING 5/16/2017 4:28:46PM Page 8 SITE PLAN 0 5 10 20 40 SCALE 1"=20'-0" SYMBOLS SCOPE OF WORK El Without Comments 9' As Noted in Red p Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer, Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to fleld test and Inspection by The Tukwila Fire Prevention Bureau. S 1 Date' • '3 ( By. /4ydw reelptd1, Y Ploy.) C b vciee}) +es 5- Yf 9 yr PROPERTY LINE TUKWILA iA FIRED P,AR T M N Please cull 206-575-x407 and give this Fire Permit No 2- S'-ocii 7.nd exact address for shut- down hutgown or resterelon approval,. PROPERTY LINE uPPrP Pi ooP t MAIM rI.00R UG BY OTHERS NEW ELEC. BELL BY OTHERS NEW 3/4 WATER METER BY OTHERS UG BY OTHERS 1 i TYP SPRINKLER PIPE /ASIR 131204 .TYP CONC. SSP DINING LIVING BUILDING CROSS SECTION NEW CITY CONNEC 1 BY OTHERS ION SCALE NTS HYDRAULIC NODE GATE VALVE-N.R.S. (GV) ELECTRIC BELL EXISTING SPRINKLER PIPING NEW SPRINKLER PIPING BY OTHERS NEW SPRINKLER PIPING BYAPFP GENERAL NOTES 1. SPRINKLER SYSTEM DESIGN PER NFPA#13D 2013. 2. ALL MATERIALS SHALL BE NEW AND UL AND/OR FM APPROVED. 3. FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH NFPA#13D (2010) AND SPECIFICATIONS. 4. IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT IS THE OWNERS RESPONSIBILITY TO PROVIDE HEAT THROUGH OUT THE WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE, DELUGE AND OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS. 5. FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE SPRINKLER SYSTEM OR ANY APPURTENANCES THEREOF: 6. ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING OR PATCHING TO BE BY OTHERS. 7. ALL PIPING IN RESIDENTIAL UNITS TO BE CPVC PIPE. 8. ALL THREADED PIPE TO BE SCHEDULE 40 BLACK JOINED WITH CAST IRON THREADED FITTINGS. 9. ALL WELDED PIPE TO BE SCHEDULE 10 BLACK JOINED WITH GROOVED FITTINGS. 10. ALL GROOVED COUPLINGS TO BE RIGID UNLESS NOTED OTHERWISE 11. SEE FP 1.10 FOR SYSTEM STANDARD DETAILS. 12. ALL HANGERS FOR CPVC ARE TO BE PER DETAILS ON SHEET FP 2.10-30 (UNO). 13. ALL HANGERS FOR STEEL PIPE TO BE NO. 15W SAMMY SIDEWINDER (UNO) 14. ALL PIPE DIMENSIONS ARE CUT LENGTHS (UNO) 15. ALL DRY MAIN PIPING TO BE SLOPED AT 1/4" PER 10'-0" AND ALL DRY LINE PIPING TO BE SLOPED AT 1/2" PER 10'-O". TO SYSTEM SPARE CABINET ( 4 l • • ( 2 2 ‘) ' i--1 11=111=1(I111111111=111=1111111 I I- , =11=111=1 1 1-111111 ; 111;111 -III III= MAINTAIN 1W ANNULAR— I I- CLEARANCE AROUND PIPE RISER DETAIL 1 2 SCALE 1/2"= l'-0" 2 X 11A" REDUCING COUPLING TYP 1" MALE CPVC ADAPTER TYP BASE OF RISER AT NODE 2 ; 111 III-111=II=III=11.1 111=111-111-11(=11 =1 I II I it 1111I T 1==1 11=111—III1 11=1 11=1 11—I 11--1 I _ —111-1 11I 1 —'1 11=1111 RISER MATERIAL LIST ITEM # QTY SIZE DESCRIPTION 1 2 3 4 1 Y TxT BALL VALVE 1 POTTER VSR WATERFLOW SWTICH 6 POTTER PBA246 6hd SPARE HEAD CABINET CONTAINING: SPARE HEAD CABINET QTY SIZE DESCRIPTION 4 1 1 1 1 1 % GL4906 RESIDENTIAL SPRINKLER HEADS 155° G15606 CONCEALED SPRINKLER HEAD 175° GL4231 QR SIDEWALL SPRINKLER HEAD 155° SPRINKLER HEAD WRENCH FOR GL4906 SPRINKLER HEAD WRENCH FOR G15606 SPRINKLER HEAD WRENCH FOR GL4231 RED HAWK FIRE PROTECTION, LLC (RHFP) WILL PROVIDE ONE WET PIPE AUTOMATIC SPRINKLER SYSTEM TO PROTECT THE NEW RESIDENCE. RHFP WILL START WORK AT EXISTING 11/2" UNDERGROUND SUPPLY LOCATED IN THE GARAGE. ALL AREAS PROTECTED BYA WET SYSTEM MUST BE MAINTAINED BY OTHERS ATA `MINIMUM 40°F TO PREVENT FREEZING. EXCLUSIONS PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT ELECTRICAL WIRING OF ANY KIND INCLUDING BUT NOT LIMITED TO WATERFLOW SWITCH, ELECTRIC BELL, AND TAMPER SWITCHES CENTRAL STATION MONITORING EQUIPMENT WIRING AND SERVICES CEILING AND WALL REMOVAUREPLACE TO FACILITATE THE INSTALLATION OF THE SPRINKLER SYSTEM. UNDERGROUND WORK OF ANY KIND DESIGN CRITERIA PER NFPA 13D (2013), CITY OF TUKWILLA. RM -01 (RESIDENCE) WET SYSTEM RESIDENTIAL DESIGN DENSITY: MOST DEMANDING 2 HEADS 18x18 MAX SPACING 17GPM/SPRINKLER PER MANUFACTURER FLOW TEST INFORMATION WATER FLOW INFORMATION HAS BEEN PROVIDED BY KING COUNTY WATER DiSTR1CT 125. STATIC PRESSURE: 119 PSI RESIDUAL PRESSURE 42 PSI RESIDUAL FLOW: 4000 GPM DRAWING INDEX FP 0.10 SITE PLAN AND NOTES FP 2.10 FLOOR FIRE SPRINKLER PLAN VICINITY MAP S Ap ticoifen Ort CenIe - RED HAWK FIRE PROTECTION, LLC -'**4"\ �111i� 4-;eto (//i/Affe 801 VALLEY AVE NW, SUITE D PUYALLUP, WA 98371 PHONE: (253) 840-9900 Fax (800) 591-4382 WA CL# REDHAHF901OP NICET Stamp WASHINOTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Byron Richard Moye 9419-0815-C Red Hawk Fire Protection, L.L.C. REDHAHFQP 05/19/2017 gnatutd Oats Approvals Required CITY OF TUKWILA OWNER / ARCHITECT Revisions Contract With: HIMPLE DRYWALL 419AVEE SNOHOMISH, WA, 98290 CONTACT: MIKE HIMPLE Phone: 425-508-2039 Fax: Contract Name: RAD RESIDENCE 12611 37TH AVE SOUTH TUKWILA, WA, 98168 Drawing Title SITE PLAN AND NOTES Key Plan Date: Job Number: • Designer: Building Permit: May 16, 2017 80082 KYLE WHITT Drawing No: FF1 0 MAY 217 TUKWILA FIRE 2 02" 741— GG //FOR CON ECTIO %T0 PL MBING f3Et7 2 t3Et7 3 WIC 2 \/ • / MSTR f3t7RM UPPER FLOOR FIRE SPRINKLER PLAN 0 1 2 4 SCALE 1/4"=1'-0" 8 HANGER FIG. 511 KIfO1 N PINING • HYDRAULICACLLY MOST DEMANDING AREA Remote Area 01 KITCHEN/DINING OCCUPANCY CLASSIFICATION !Residential 18X18 TOTAL WATER REQUIRED 34.30 TOTAL PRESSURE REQUIRED 161.827 BASE of RISER (gpm)34.30 Finish BASE of RISER (psi) 129.916 SAFETY MARGIN (psi) 1+57.162 (48.0%) MAIN FLOOR FIRE SPRINKLER PLAN • PAMIVY OR 604 /TO PLUMBING EC .I YVON • N r'\ /\ i/ • LIVING 0 GARAGE 0 1 2 4 8 SCALE 1/4"=1'-0" ' Sprinkler Legend Symbol Manufacturer Response Type SIN K -Factor Size Temperature Finish Escutcheon Spacing Discharge Quantity • Globe Quick Pendent GL4906 4.9 '/z 155'F Bronze CONC WHITE 18X18 17GPM 11 0 Globe Quick Pendent GL5606 5.6 'A 175°F Bronze CONC WHITE 225SQ FT NA 1 ( ) Globe Quick Pendent GL5635 5.6 1 155`'F White REC WHITE 225SQ FT NA 4 Total = 16 NOTES 1. ALL CEILINGS TO BE 8-0 UNO 2. ALL PIPE TO BE 1" CPVC UNO 3. SPRINKLERS OMITTED FROM ALL CLOSETS MEETING THE REQUIREMENTS OF SECTION 8.6.3 OF NFPA 13D (2013) AREAS MARKED WITH HATCH 4. SPRINKLERS OMITTED FROM ALL BATHROOMS UNDER 55 FT2 PER SECTION 8.6.2 OF NFPA 13D (2013) AREAS MARKED WITH HATCH HANGER FIG. 514 1VOOD JOIST OR r COMPOSITE WOOD JOIST. 1 1/2" "NO BLOCK" HANGER MINIMUM DISTANCES FOR ORDINARY- AND INTERMEDIATE -TEMPERATURE RESIDENTIAL SPRINKLERS (NFPA 13D-2002 TABLE 7.5.5.3) HEAT SOURCE MINIMUM DISTANCE FROM EDGE OF SOURCE TO ORDINARY- SPRINKLER (INCHES) MINIMUM DISTANCE FROM EDGE OF SOURCE TO INTERMEDIATE - SPRINKLER (INCHES) SIDE OF OPEN OR RECESSED FIREPLACE 36 t 2 FRONT OF RECESSED FIREPLACE 60 36 COAL- OR WOOD BURNING STOVE 42 12 KITCHEN RANGE 18 9 WALL OVEN 18 9 HOT AIR FLUES 18 9 UNINSULATED HEAT DUCTS 18 9 UNINSULATED HOT WATER PIPES 12 6 SIDE OF CEILING- OR WALL MOUNTED HOT AIR DIFFUSERS 24 12 FRONT OF WALL- MOUNTED HOT AIR DIFFUSERS 36 18 HOT WATER HEATER OR FURNACE 6 3 LIGHT FIXTURE: OW -250W 6 3 LIGHT FIXTURE 250W -499W 12 6 HANGERS - PIPE HANGERS SHALL BE SIZED, SPACED AND INSTALLED AS REQUIRED BY NFPA:STANDARDS - NO OTHER PIPING AND/OR DEVICES ARE TO BE ATTACHED TO THE SPRINKLER PIPE HANGER SYSTEM UNLESS THE HANGER HAS BEEN SPECIFICALLY DESIGNED FOR THE ACDITIONAL LOADING. - THIS CONTRACT DOES NOT INCLUDE ANY MATERIAL OR DEVICES TO IMPROVE THE STRUCTURAL STRENGTH OF THE BUILDING TO ENABLE IT TO CARRY THE LOAD OF THE FIRE PROTECTION SYSTEM. - SEE DETAILS ON THIS SHEET FOR THE SPECIFIC HANGER ASSEMBLIES USED FOR THIS INSTALLATION. NFPA 13, 2010 Edition Table 9.2.2.1 MAXIMUM DISTANCE BETWEEN HANGERS (ft - in) PIPE TYPE CPVC NOMINAL PIPE SIZE ( IN. ) 3/4 1 1.1/4 1 1/2 2 2 1/2 3 5-6 6-0 6-6 7-0 8-0 9-0 10-0 Caution: It is important that the insulation be installed tight against the joists. In unheated areas, any spaces or voids between the insulation,and the joists causes the water in the fire sprinkler piping to freeze: Caution: For areas having temperatures of 0°F (-18°C) or lower, an additional batt of insulation covering the joist and the fire sprinkler piping should be used. If this is not done, freeze -ups can occur in the sprinkler piping. INSULATION DETAILS NTS REDHAWK. FIRE PROTECTION, LLC 801 VALLEY AVE NW, SURE D PUYALLUP, WA 98371 PHONE: (253) 840-9900 FAX (800) 591-4382 WA CL# REDHAHF901QP NICET Stamp WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Byron Richard Moye 9419-0815-C Red Hawk Fire Protection, L.L.C. REDHAHFQP gnats 05/19/2017 Date Approvals Required CITY OF TUKWILA OWNER / ARCHITECT Revisions Contract With: HIMPLE DRYWALL 419AVEE SNOHOMISH, WA, 98290 CONTACT: MIKE HIMPLE Phone: 425-508-2039 Fax: Contract Name: RAD RESIDENCE. 12611 37TH AVE SOUTH TUKWILA, WA, 98168 Drawing Title FLOOR FIRE SPRINKLER PLAN Key Plan Date: Job Number: Designer: Building Permit: May 16, 2017 80082 KYLE WHITT Drawing No. FP2al 0