HomeMy WebLinkAboutPP - 14408 34TH LN S - OVERBECK - PERMITS AND PLANS14408 34TH LN S ASSOCIATED PERMITS 16-5-171 D16-0169 41$44tx"Rtst SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: (. 133(O 0C? 10 Site Address: /119 1i) 3 Y6 /t,1- S. Suite Number: Floor: \ Tenant Name: '—" �l�'`-J '" (C"'`' 5 ' ✓� 7�' W New Tenant? 111- Yes ❑ - No Property Owner's Name: / 1Utit\ if g O f C ivi'f s, //:: / Mailing Address: (�2 S / 9c�! t / W Sf (c/1 /d G �/ CONTACT PERSON -if there are questions about the submittal. Name: /i/ke Gi 'i eL1< Company Name: P �/ c� / c Mailing Address: / (� gt 7M/4/4 J� 7/ rM V64 cpv>n E-mail Address: /)// /� L �`''/ G'/lif l c o,C ..t)Ate pf, "yCitye State Zip Fax Number /� City State Zip Day Telephone: 26. Contractor's City of Tukwila NICET III number: /7C lt%E>51L Business License number: Total number of new/relocated devices or sprinkler heads: zz Valuation of Project (contractor's bid price): $ >06)C3 Scope of Work (please provide detailed information): 2 Z_ 3'"'4"'/ 4, 15- t70.'vC/^ / 'y S y S ; ►�• j Pk k11 S+ /tio:' 0el517 „,� PERMIT APPLICATION NOTES Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: r Plan Permit App.doc Date: 41° (i( Day Telephone: 2'o ' 757. CCC -5 7 8/22/14 TFD FP Form 8 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: lieW4e—C1( Type of Inspection: F 174—^-iirr----- Address: Suite #: % n4j- g 5mi Contact Person: d . Special Instructions: Permits: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: fr ft -z m-Pfn-mom 1) Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: c----.4-- Date:*/jb h� Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 1 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Plio-0/61 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: p ut-n6c-7- Sprinklers: Type of Inspection: ce-verL, reti oftoI silt 61— Address:Contact Suite #: f44Q � s_ Person: SpecialInstructions: r.� Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: * O k- ro �'YL fifT7-- % —iN6j 15 fin/ ,i-uie-D IP Pty0(45- Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: iyvtick fry s Date: La f (5fg) Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 A-Pex Design Services, Inc. -EP 10731 47th PI W Mukilteo, WA 98275 425-493-9680 sales@a-pexdesignservices.com Job Name : 31 TOWNHOMES UNIT B. - One Head Calculation (H.12) Drawing Location : 3429 S 144TH ST TUKWILA WA Remote Area Contract : 150805-02 Data File : 150805-02 31 TH Unit B18.wx1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 • A-Pex Design Services, Inc. -EP Page 1 31 TOWNHOMES UNIT B - One Head Calculation (H.12) Date 8/5/2015 HYDRAULIC DESIGN INFORMATION SHEET • Name - 31 TOWNHOMES UNIT B Date - 8-5-2015 Location - TUKWILA WA Building - System No. - Contractor - Contract No. - 150805-02 Calculated By - NOAH EAKMAN Drawing No. - Construction: (X) Combustible ( ) Non -Combustible Ceiling Height OCCUPANCY - RESIDENTIAL S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: (X)1 ( )2 ( )4 ( ) S ( )Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 7.04 Psi(X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 16 ( ) Deluge ( ) PreAction E Domestic Flow Added - 0 Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make RELIABLE Model RFC49 I Elevation at Highest Outlet - 124 Feet Size 3/8 K -Factor 4.9 G Note: Temperature Rating 155 N Calculation Gpm Required 13 Psi Required 47.18 At Ref Pt STR. Summary C -Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 60 Elev. R Residual (Psi) - 55 Other Well Flow (Gpm) - 300 Proof Flow Gpm S Elevation - 100 P Location: P L Source of Information: Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C LO 0 N N 0;0 N ± C O IrTs7 0 is 0 v a) a) 2 a) c a0 w' cCp a)Z U D N � CO w C0 O)= a) Z C x CD 1_ d c - M Q Fittings Used Summary N 2 O U To U to N N c 0 Co H Z W 2 N E c Z J 00) a) lL < M N �(.0e- 0 0 0 0 ,- 0 ✓ - 0 0 0 I) 0' 0)000 0 - (0000 �Mh f�000 • 0 • N (00000 N O �N If) I) 000 O 0 M 0 0 0 ▪ 0 ▪ M M 0 0 0 N 10 ▪ N ("Ni 0 0 0 O O • 1- N N 0 0 0 r -- N- G01-1- 000 10 r-.- ' 000 N-(0 '-000 0 CO 1- c., �•cl• %-00 N ▪ (0- CD '1' N �NLO CV N • �� - N N - CV '- M F) CV O C uj ` y � N o N 7 ELL O CD V u�i >,i� N U) C 0) 0 7 N c - N 0 w c U Q > O- C Eva LL O O N c Z to .4- U ' � CD 1•Z)3 ) a w � N� ?� 0)) C c O L N O t y • N t * N () czl t0 N N.SS. N* d _c (!i "a S '0 to CN 10 N N +L_ O N N c Q 3 0 co N U N 0 C _O. E N N U (1) O) O °• 0 0)N` N U- 0- c c aE E �_ to E to > a 4 C O 'O moc c • L -0 y C > in~ N p)t0 c 0) C -0 (ts w y 4- c a) c c j c'- p C 4- .S a) > E O 0 3' 2 m oaj .2 co a O C N Y 0) V'0 :: 0 w m a) C N p c a) ovC')�0)F--F- o) h c > 0 o c o a a a • J C) CD N Q O O - N LL 7 7 7 E �= .- 0,i) i) N E 1 0 0 0• 0 a E c 0) _ c U E c 0 Oi V 0QQ Q ir)... �X U •E N .. N Na N w y O N u_ _ w ., C ! N O 2 0 UwC I -DDD LLQ ZW 0 cnn N.O Flow Summary - NFPA 2007 A-Pex Design Services, Inc. -EP Page 4 31 TOWNHOMES UNIT B - One Head Calculation (H.12) Date 8/5/2015 Node at Static Residual Source Pressure Pressure SUPPLY ANALYSIS Flow Available Pressure Total Demand Required Pressure STR 60.0 55 300.0 59.985 13.0 47.182 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes H.12 124.0 H.5 124.0 H.3 124.0 T.23 124.0 T.25 116.0 T.24 116.0 H.20 108.0 T.39 108.0 T.38 108.0 T.43 108.0 T.42 108.0 T.41 108.0 T.40 108.0 S.1 104.0 CPL 100.0 MTR 100.0 STR 100.0 H.11 124.0 T.32 124.0 T.34 124.0 T.35 116.0 H.17 116.0 H.16 116.0 H.15 116.0 T.37 116.0 T.36 116.0 H.14 124.0 H.13 124.0 T.29 124.0 T.30 124.0 H.4 124.0 H.6 124.0 T.26 124.0 H.10 124.0 T.33 116.0 T.31 116.0 T.46 108.0 H.22 108.0 T.45 108.0 T.44 108.0 T.28 116.0 T.27 116.0 4.9 7.04 13.0 7.67 7.91 8.0 11.84 11.87 15.49 15.51 15.66 15.68 15.71 15.71 15.78 18.25 30.9 31.51 47.18 7.6 7.74 7.88 11.81 11.84 11.84 11.86 11.87 11.94 8.01 8.1 8.18 8.34 8.1 8.21 8.22 8.27 11.83 11.85 15.61 15.63 15.66 15.67 11.85 11.87 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - NFPA 2007 A-Pex Design Services, Inc. -EP Page 5 31 TOWNHOMES UNIT B - One Head Calculation (H.12) Date 8/5/2015 NODE ANALYSIS (cont.) Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes H.7 H.8 H.9 H.1 H.2 H.21 H.19 H.18 116.0 116.0 116.0 116.0 116.0 108.0 108.0 108.0 11.87 11.85 11.85 11.87 11.87 15.63 15.66 15.69 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams - 2007 A-Pex Design Services, Inc. -EP Page 6 31 TOWNHOMES UNIT B - One Head Calculation (H.12) Date 8/5/2015 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes ****** H.12 5.68 0.862 1 UeI 11.0 17.000 7.040 to 150.0 0.0 12.000 0.0 H.5 5.68 0.0219 0.0 29.000 0.634 K Factor = 4.90 Vel = 3.12 H.5 0.0 0.862 1 Utr 2.0 9.000 7.674 to 150.0 0.0 2.000 0.0 H.3 5.68 0.0218 0.0 11.000 0.240 Vel = 3.12 H.3 0.0 0.862 1 Utr 2.0 2.000 7.914 to 150.0 0.0 2.000 0.0 T.23 5.68 0.0217 0.0 4.000 0.087 Vel = 3.12 T.23 -2.33 0.862 2Utb 34.0 18.000 8.001 to 150.0 0.0 28.000 3.465 T.25 3.35 0.0082 0.0 46.000 0.378 Vel = 1.84 T.25 -0.99 0.862 1 Utr 2.0 4.000 11.844 to 150.0 0.0 2.000 0.0 T.24 2.36 0.0043 0.0 6.000 0.026 Vel = 1.30 T.24 0.27 0.862 1 Utr 2.0 14.000 11.870 to 150.0 1 Utb 17.0 16.000 3.465 H.20 2.63 0.0053 0.0 30.000 0.158 Vel = 1.45 H.20 0.0 0.862 0.0 3.000 15.493 to 150.0 0.0 0.0 0.0 T.39 2.63 0.0053 0.0 3.000 0.016 Vel = 1.45 T.39 0.0 0.862 1 Utb 17.0 2.000 15.509 to 150.0 1 UeI 11.0 26.000 0.0 T.38 2.63 0.0052 0.0 28.000 0.147 Vel = 1.45 T.38 -1.18 0.862 1 Utb 17.0 2.000 15.656 to 150.0 0.0 14.000 0.0 T.43 1.45 0.0018 0.0 16.000 0.028 Vel = 0.80 T.43 1.46 1.054 1 Utr 4.0 6.000 15.684 to 150.0 0.0 4.000 0.0 T.42 2.91 0.0024 0.0 10.000 0.024 Vel = 1.07 T.42 1.63 1.054 0.0 1.000 15.708 to 150.0 0.0 0.0 0.0 T.41 4.54 0.0050 0.0 1.000 0.005 Vel = 1.67 T.41 1.18 1.054 1 Utr 4.0 4.000 15.713 to 150.0 0.0 4.000 0.0 T.40 5.72 0.0084 0.0 8.000 0.067 Vel = 2.10 T.40 7.28 1.054 1T 2.44 8.000 15.780 to 150.0 1 Utb 9.0 11.440 1.732 S.1 13.0 0.0379 0.0 19.440 0.737 Vel = 4.78 S.1 0.0 1.054 1E 1.22 20.000 18.249 to 150.0 1T 2.44 4.067 11.732 CPL 13.0 0.0380 1G 0.407 24.067 0.914 * * Fixed Loss = 10 Vel = 4.78 CPL 0.0 1.38 2E 9.066 50.000 30.895 to 150.0 1C 1.511 10.577 0.0 MTR 13.0 0.0102 0.0 60.577 0.618 Vel = 2.79 MTR 0.0 1.025 2E 5.4 10.000 31.513 to 150.0 0.0 5.400 15.000 STR 13.0 0.0434 0.0 15.400 0.669 * * Fixed Loss = 15 Vel = 5.05 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-Pex Design Services, Inc. -EP Page 7 31 TOWNHOMES UNIT B - One Head Calculation (H.12) Date 8/5/2015 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes ****** H.12 to H.11 0.0 13.00 7.32 7.32 47.182 K Factor = 1.89 0.862 150.0 0.0349 1Uel 11.0 0.0 0.0 4.000 12.000 16.000 7.040 0.0 0.558 Vel = 4.02 H.11 to T.32 0.0 7.32 0.862 150.0 0.0350 1 Utr 2.0 0.0 0.0 2.000 2.000 4.000 7.598 0.0 0.140 Vel = 4.02 T.32 to T.34 0.0 7.32 0.862 150.0 0.0348 1 Utr 2.0 0.0 0.0 2.000 2.000 4.000 7.738 0.0 0.139 Vel = 4.02 T.34 to T.35 -3.26 4.06 0.862 150.0 0.0117 2Utb 34.0 0.0 0.0 12.000 28.000 40.000 7.877 3.465 0.469 Vel = 2.23 T.35 to H.17 -2.80 1.26 0.862 150.0 0.0013 1Uel 11.0 0.0 0.0 7.000 12.000 19.000 11.811 0.0 0.025 Vel = 0.69 H.17 to H.16 0.0 1.26 0.862 150.0 0.0012 0.0 0.0 0.0 4.000 0.0 4.000 11.836 0.0 0.005 Vel = 0.69 H.16 to H.15 0.0 1.26 0.862 150.0 0.0014 1 Utr 2.0 0.0 0.0 10.000 2.000 12.000 11.841 0.0 0.017 Vel = 0.69 H.15 to T.37 0.0 1.26 0.862 150.0 0.0013 1 Utr 2.0 0.0 0.0 8.000 2.000 10.000 11.858 0.0 0.013 Vel = 0.69 T.37 to T.36 0.43 1.69 0.862 150.0 0.0023 2Utb 34.0 0.0 0.0 1.000 28.000 29.000 11.871 0.0 0.067 Vel = 0.93 T.36 to T.40 T.34 to H.14 5.59 7.28 0.0 7.28 3.26 3.26 1.054 150.0 0.0130 1 Utr 4.0 0.0 0.0 25.000 4.000 29.000 11.938 3.465 0.377 Vel = 2.68 15.780 K Factor = 1.83 0.862 150.0 0.0078 1Uel 11.0 0.0 0.0 5.000 12.000 17.000 7.877 0.0 0.133 Vel = 1.79 H.14 to H.13 0.0 3.26 0.862 150.0 0.0078 0.0 0.0 0.0 12.000 0.0 12.000 8.010 0.0 0.094 Vel = 1.79 H.13 to T.29 0.0 3.26 0.862 150.0 0.0078 1 Utr 2.0 0.0 0.0 8.000 2.000 10.000 8.104 0.0 0.078 Vel = 1.79 T.29 to T.30 0.0 3.26 0.862 150.0 0.0078 1 Utr 1 Utb 2.0 17.0 0.0 4.000 16.000 20.000 8.182 0.0 0.156 Vel = 1.79 T.30 to T.36 2.33 5.59 1.054 150.0 0.0079 1 Utr 4.0 0.0 0.0 13.000 4.000 17.000 8.338 3.465 0.135 Vel = 2.06 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-Pex Design Services, Inc. -EP 31 TOWNHOMES UNIT B - One Head Calculation (H.12) Page 8 Date 8/5/2015 Hyd. Ref. Point Qa Dia. .,C„ Qt Pf/Ft Fitting or Eqv. Ln. Pipe Ftng's Total Pt Pe Pf Pt Pv Pn Notes ****** 0.0 5.59 11.938 K Factor = 1.62 T.23 2.33 0.862 1 Uel to 150.0 1 Utr H.4 2.33 0.0042 11.0 2.0 0.0 9.000 14.000 23.000 8.001 0.0 0.097 Vel = 1.28 H.4 0.0 0.862 1 UeI 11.0 to 150.0 0.0 H.6 2.33 0.0042 0.0 14.000 12.000 26.000 8.098 0.0 0.110 Vel = 1.28 H.6 0.0 0.862 1 Utr 2.0 to 150.0 0.0 T.26 2.33 0.0040 0.0 1.000 2.000 3.000 8.208 0.0 0.012 Vel = 1.28 T.26 0.0 0.862 1 Utr 2.0 to 150.0 0.0 H.10 2.33 0.0043 0.0 9.000 2.000 11.000 8.220 0.0 0.047 Vel = 1.28 H.10 0.0 0.862 1 Utb 17.0 to 150.0 0.0 T.30 2.33 0.0042 0.0 3.000 14.000 17.000 8.267 0.0 0.071 VeI = 1.28 0.0 2.33 8.338 K Factor = 0.81 T.35 2.80 0.862 1 Utr 2.0 to 150.0 0.0 T.33 2.8 0.0057 0.0 1.000 2.000 3.000 11.811 0.0 0.017 Vel = 1.54 T.33 0.0 0.862 1 Utr 2.0 to 150.0 0.0 T.31 2.8 0.0060 0.0 2.000 2.000 4.000 11.828 0.0 0.024 Vel = 1.54 T.31 0.29 0.862 2Utb 34.0 to 150.0 0.0 T.46 3.09 0.0070 0.0 14.000 28.000 42.000 11.852 3.465 0.296 Vel = 1.70 T.46 -1.47 0.862 1 Utr 2.0 to 150.0 0.0 H.22 1.62 0.0021 0.0 6.000 2.000 8.000 15.613 0.0 0.017 Vel = 0.89 H.22 0.0 0.862 1 UeI 11.0 to 150.0 0.0 T.45 1.62 0.0021 0.0 2.000 12.000 14.000 15.630 0.0 0.030 Vel = 0.89 T.45 0.0 0.862 to 150.0 T.44 1.62 0.0022 0.0 0.0 0.0 4.000 0.0 4.000 15.660 0.0 0.009 Vel = 0.89 T.44 0.0 0.862 1 Utb to 150.0 1 Utr T.42 1.62 0.0022 17.0 2.0 0.0 2.000 16.000 18.000 15.669 0.0 0.039 Vel = 0.89 0.0 1.62 15.708 K Factor = 0.41 T.25 0.99 0.862 1 Utr 2.0 to 150.0 0.0 T.28 0.99 0.0010 0.0 3.000 2.000 5.000 11.844 0.0 0.005 Vel = 0.54 T.28 -0.29 0.862 2Utb 34.0 to 150.0 0.0 T.27 0.7 0.0004 0.0 10.000 28.000 38.000 11.849 0.0 0.017 Vel = 0.38 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-Pex Design Services, Inc. -EP Page 9 31 TOWNHOMES UNIT B - One Head Calculation (H.12) Date 8/5/2015 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes T.27 -0.27 0.862 1 Uel 11.0 5.000 to 150.0 0.0 12.000 H.7 0.43 0.0002 0.0 17.000 11.866 0.0 0.003 Vel = 0.24 H.7 0.0 0.862 1 Utr 2.0 7.000 to 150.0 0.0 2.000 T.37 0.43 0.0002 0.0 9.000 11.869 0.0 0.002 Vel = 0.24 0.0 0.43 11.871 K Factor = 0.12 T.28 0.28 0.862 1 UeI 11.0 3.000 to 150.0 0.0 12.000 H.8 0.28 0.0001 0.0 15.000 11.849 0.0 0.001 Vel = 0.15 H.8 0.0 0.862 1 UeI 11.0 4.000 to 150.0 0.0 12.000 H.9 0.28 0.0001 0.0 16.000 11.850 0.0 0.001 Vel = 0.15 H.9 0.0 0.862 1 Utr 2.0 3.000 to 150.0 0.0 2.000 T.31 0.28 0.0002 0.0 5.000 11.851 0.0 0.001 Vel = 0.15 0.0 0.28 11.852 K Factor = 0.08 T.27 0.27 0.862 1 Utr 2.0 12.000 to 150.0 0.0 2.000 H.1 0.27 0.0001 0.0 14.000 11.866 0.0 0.001 Vel = 0.15 H.1 0.0 0.862 2UeI 22.0 10.000 to 150.0 0.0 24.000 H.2 0.27 0.0001 0.0 34.000 11.867 0.0 0.003 Vel = 0.15 H.2 0.0 0.862 1 Utr 2.0 4.000 to 150.0 0.0 2.000 T.24 0.27 0.0 0.0 6.000 11.870 0.0 0.0 Vel = 0.15 0.0 0.27 11.870 K Factor = 0.08 T.46 1.46 0.862 1 Utr 2.0 6.000 to 150.0 0.0 2.000 H.21 1.46 0.0018 0.0 8.000 15.613 0.0 0.014 Vel = 0.80 H.21 0.0 0.862 1 UeI 11.0 6.000 to 150.0 1 Utb 17.0 26.000 T.43 1.46 0.0018 0.0 32.000 15.627 0.0 0.057 Vel = 0.80 0.0 1.46 15.684 K Factor = 0.37 T.38 1.18 0.862 1 Utr 2.0 1.000 to 150.0 0.0 2.000 H.19 1.18 0.0013 0.0 3.000 15.656 0.0 0.004 Vel = 0.65 H.19 0.0 0.862 1 UeI 11.0 9.000 to 150.0 1 Utr 2.0 14.000 H.18 1.18 0.0012 0.0 23.000 15.660 0.0 0.027 Vel = 0.65 H.18 0.0 0.862 1 Utb 17.0 8.000 to 150.0 0.0 14.000 T.41 1.18 0.0012 0.0 22.000 15.687 0.0 0.026 Vel = 0.65 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams - A-Pex Design Services, Inc. -EP Page 10 31 TOWNHOMES UNIT B - One Head Calculation (H.12) Date 8/5/2015 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes ****** 1.18 15.713 K Factor = 0.30 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A-Pex Design Services, Inc. -EP 10731 47th PI W Mukilteo, WA 98275 425-493-9680 sales@a-pexdesignservices.com Job Name : 31 TOWNHOMES UNIT B - Two Head Calculation (H.4 & H.3) Drawing Location : 3429 S 144TH ST TUKWILA WA Remote Area : Contract : 150805-02 Data File : 150805-02 31 TH Unit B18.wx2 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 • A-Pex Design Services, Inc. -EP Page 1 31 TOWNHOMES UNIT B. - Two Head Calculation (H.4 & H.3) Date 8/5/2015 HYDRAULIC DESIGN INFORMATION SHEET Name - 31 TOWNHOMES UNIT B Location - TUKWILA WA Building - Contractor - Calculated By - NOAH EAXMAN Construction: (X) Combustible OCCUPANCY - RESIDENTIAL Date - 8-5-2015 System No. - Contract No. - 150805-02 Drawing No. - ( ) Non -Combustible Ceiling Height S Y S T E Type of Calculation: ( )NFPA 13 Residential Number of Sprinklers Flowing: ( )1 (X)2 ( )Other ( )Specific Ruling ( )NFPA 13R (X)NFPA 13D ( )4 ( ) Made by Date M Listed Flow at Start Point Listed Pres. at Start Point - 9 D MAXIMUM LISTED SPACING 12 E Domestic Flow Added S Additional Flow Added I Elevation at Highest Outlet G Note: N - 9 Gpm Psi x 12 - 0 Gpm Gpm - 124 Feet System Type (X) Wet • ( ) Dry ( ) Deluge ( ) PreAction Sprinkler or Nozzle Make RELIABLE Model RFC30 Size 3/8 K -Factor 3 Temperature Rating 155 Calculation Gpm Required 18.048 Summary C -Factor Used: Psi Required 52.2 At Ref Pt STR Overhead 150 Underground 150 W Water Flow Test: A Date of Test T Time of Test E Static (Psi) - 60 R Residual (Psi) - 55 Flow (Gpm) - 300 S Elevation - 100 Pump Data: Rated Cap. Psi Elev. Other Tank or Reservoir: Cap. Elev. Well Proof Flow Gpm P Location: P L Source of Information: Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C LC) 0 N Ln NCCO cri N C3 d0 cfs i atS 0 .@ 0 CO 0 v m m 2 3 aI— W' coo (6 I a) Z a) w W c0 0 rn1 N Z O 2 x0 CU Q M r City Water Supply: Demand: C1 - Static Pressure : 60 D1 - Elevation : 10.394 C2 - Residual Pressure: 55 D2 - System Flow : 18.048 C2 - Residual Flow : 300 D2 - System Pressure : 52.199 Hose ( Demand) D3 - System Demand : 18.048 Safety Margin : 7.774 LLC) 50 100 150 200 250 300 350 400 450 FLOW (N^1.85) • • • • r V N r 0 ; 0 0 CF C' ) C 0 Or 0 0 0 0 0 0 0 0 0 0 0) CO h CO LC) M N r CL CC W CO CI) D Q W Fittings Used Summary r O N cl CO CO N co 4- c0 c0 d0 2 aC$ c tra O U C0 0 N d I- 6 U c co cc Z .Z N Cn W c0 (2 0 N O F' t r < a) c m 1° O Z a) J • a)N .. �< I... CO N T- CJD rr 000 0 r o 115 r r 0 0 0 tC) O r rCr0)000 o rvOao000 to r r co 1- h 0 0 0 h O r N 0 CO 000 N O N to t() 000 CO to r r CO 0 0 0 et 0 r r M CO 0 0 0 N to r r N N 0 0 0 O O r r N N 0 0 0 o r co r,- 0 0 0 C cj `- y .N N O N 5 rt`r-000 ELL cs i- o N 1°131 U rCOr-000 �%.� _ o CD m .Q x- LO oao� '46 c) �LaL O c) c0 O c Z y > C) ' N 'O •O LL V N rvraoe-a-N V N V N a 0 s rn�o03 c O_c C6 @ N cL) LI r M r 0- 0) j y y L y U c N ig*as 42 0f6 4N;fC/) r N %- i.0 � A- N N� y -" y 3 C- a C/) --,..11-3 3 "O N ` CA r n 0 a •C j Y �. L rNrarrN (0 C6 cn ) U a3 y a)c _a N V a ` U a) U) O a 0 O N N r N r M M N r L L O -� N E E >as .O t`w C0 O p z c t Oy y C Ninth 0) C0 N N * = N 0) 0 'O CO t y r- N. a 0 3 3 O N cc0 C .a ; a) a 0. , a.c a'6i 'c ay) W F- W U cD `i ,- 0 N N c y 0 y@ 7 N ctiy c N L O 'Np Ur w D1 H H CD _C y Z> O o c o 3 aa)) 0 0 iA c6 cc0 - w oaaa _1(1)cw.CQo �m CLL 7 7 7 .0 y 'C �N a y Ob Wb)Q o o E ?•C y� C Um c O cC coN.= C Na) N-0 N V y E 0 3 y ai N O- j 0 75 la c f°�o� o0-6_,.a w C9 1-»> > 5 J LL d Z W o cn co _L- c..) 1 Flow Summary - NFPA 2007 A-Pex Design Services, Inc. -EP Page 4 31 TOWNHOMES UNIT B - Two Head Calculation (H.4 & H.3) Date 8/5/2015 Node at Static Residual Source Pressure Pressure SUPPLY ANALYSIS Available Flow Pressure Total Demand Required Pressure STR 60.0 55 300.0 59.972 18.05 52.199 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes H.4 124.0 H.6 124.0 T.26 124.0 H.10 124.0 T.30 124.0 T.36 116.0 T.40 108.0 S.1 104.0 CPL 100.0 MTR 100.0 STR 100.0 T.23 124.0 T.25 116.0 T.24 116.0 H.20 108.0 T.39 108.0 T.38 108.0 T.43 108.0 T.42 108.0 T.41 108.0 H.3 124.0 H.5 124.0 H.12 124.0 H.11 124.0 T.32 124.0 T.34 124.0 T.35 116.0 T.33 116.0 T.31 116.0 T.46 108.0 H.22 108.0 T.45 108.0 T.44 108.0 H.14 124.0 H.13 124.0 T.29 124.0 T.28 116.0 T.27 116.0 H.7 116.0 T.37 116.0 H.8 116.0 H.9 116.0 3 3 9.0 9.66 9.74 10.02 10.45 14.18 18.34 21.43 34.84 35.97 52.2 9.14 13.97 14.04 17.8 17.84 18.12 18.17 18.22 18.22 9.1 9.3 9.83 10.13 10.2 10.27 14.05 14.06 14.08 18.05 18.08 18.13 18.15 10.32 10.36 10.39 14.0 14.04 14.06 14.08 14.03 14.07 9.0 9.05 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - NFPA 2007 A-Pex Design Services, Inc. -EP Page 5 31 TOWNHOMES UNIT B - Two Head Calculation (H.4 & H.3) Date 8/5/2015 NODE ANALYSIS (cont.) Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes H.2 H.1 H.17 H.16 H.15 H.21 H.19 H.18 116.0 116.0 116.0 116.0 116.0 108.0 108.0 108.0 14.04 14.04 14.06 14.06 14.07 18.08 18.12 18.18 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams - 2007 • A-Pex Design Services, Inc. -EP Page 6 31 TOWNHOMES UNIT B - Two Head Calculation (H.4 & H.3) Date 8/5/2015 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes ****** H.4 6.16 0.862 1 UeI 11.0 14.000 9.000 to 150.0 0.0 12.000 0.0 H.6 6.16 0.0254 0.0 26.000 0.660 K Factor = 3.00 Vel = 3.39 H.6 0.0 0.862 1 Utr 2.0 1.000 9.660 to 150.0 0.0 2.000 0.0 T.26 6.16 0.0253 0.0 3.000 0.076 Vel = 3.39 T.26 0.0 0.862 1 Utr 2.0 9.000 9.736 to 150.0 0.0 2.000 0.0 H.10 6.16 0.0254 0.0 11.000 0.279 Vel = 3.39 H.10 0.0 0.862 1 Utb 17.0 3.000 10.015 to 150.0 0.0 14.000 0.0 T.30 6.16 0.0254 0.0 17.000 0.431 Vel = 3.39 T.30 1.92 1.054 1 Utr 4.0 13.000 10.446 to 150.0 0.0 4.000 3.465 T.36 8.08 0.0157 0.0 17.000 0.267 Vel = 2.97 T.36 2.11 1.054 1 Utr 4.0 25.000 14.178 to 150.0 0.0 4.000 3.465 T.40 10.19 0.0242 0.0 29.000 0.701 Vel = 3.75 T.40 7.86 1.054 1T 2.44 8.000 18.344 to 150.0 1 Utb 9.0 11.440 1.732 S.1 18.05 0.0696 0.0 19.440 1.353 Vel = 6.64 S.1 0.0 1.054 1E 1.22 20.000 21.429 to 150.0 1T 2.44 4.067 11.732 CPL 18.05 0.0696 1G 0.407 24.067 1.675 * * Fixed Loss = 10 Vel = 6.64 CPL 0.0 1.38 2E 9.066 50.000 34.836 to 150.0 1C 1.511 10.577 0.0 MTR 18.05 0.0187 0.0 60.577 1.135 Vel = 3.87 MTR 0.0 1.025 2E 5.4 10.000 35.971 to 150.0 0.0 5.400 15.000 STR 18.05 0.0797 0.0 15.400 1.228 * * Fixed Loss = 15 Vel = 7.02 0.0 18.05 52.199 K Factor = 2.50 H.4 2.84 0.862 1 Uel 11.0 9.000 9.000 to 150.0 1 Utr 2.0 14.000 0.0 T.23 2.84 0.0060 0.0 23.000 0.139 Vel = 1.56 T.23 3.87 0.862 2Utb 34.0 18.000 9.139 to 150.0 0.0 28.000 3.465 T.25 6.71 0.0297 0.0 46.000 1.367 Vel = 3.69 T.25 -2.77 0.862 1 Utr 2.0 4.000 13.971 to 150.0 0.0 2.000 0.0 T.24 3.94 0.0110 0.0 6.000 0.066 Vel = 2.17 T.24 -0.20 0.862 1 Utr 2.0 14.000 14.037 to 150.0 1 Utb 17.0 16.000 3.465 H.20 3.74 0.0101 0.0 30.000 0.302 Vel = 2.06 H.20 0.0 0.862 0.0 3.000 17.804 to 150.0 0.0 0.0 0.0 T.39 3.74 0.0103 0.0 3.000 0.031 Vel = 2.06 T.39 0.0 0.862 1 Utb 17.0 2.000 17.835 to 150.0 1 UeI 11.0 26.000 0.0 T.38 3.74 0.0101 0.0 28.000 0.282 Vel = 2.06 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-Pex Design Services, Inc. -EP Page 7 31 TOWNHOMES UNIT B - Two Head Calculation (H.4 & H.3) Date 8/5/2015 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes ****** T.38 -1.66 0.862 1 Utb 17.0 2.000 18.117 to 150.0 0.0 14.000 0.0 T.43 2.08 0.0034 0.0 16.000 0.055 Vel = 1.14 T.43 1.94 1.054 1 Utr 4.0 6.000 18.172 to 150.0 0.0 4.000 0.0 T.42 4.02 0.0043 0.0 10.000 0.043 Vel = 1.48 T.42 2.18 1.054 0.0 1.000 18.215 to 150.0 0.0 0.0 0.0 T.41 6.2 0.0090 0.0 1.000 0.009 Vel = 2.28 T.41 1.66 1.054 1 Utr 4.0 4.000 18.224 to 150.0 0.0 4.000 0.0 T.40 7.86 0.0150 0.0 8.000 0.120 Vel = 2.89 0.0 7.86 18.344 K Factor = 1.84 T.23 -3.87 0.862 1 Utr 2.0 2.000 9.139 to 150.0 0.0 2.000 0.0 H.3 -3.87 -0.0107 0.0 4.000 -0.043 Vel = 2.13 H.3 9.05 0.862 1 Utr 2.0 9.000 9.096 to 150.0 0.0 2.000 0.0 H.5 5.18 0.0184 0.0 11.000 0.202 K Factor = 3.00 Vel = 2.85 H.5 0.0 0.862 1 UeI 11.0 17.000 9.298 to 150.0 0.0 12.000 0.0 H.12 5.18 0.0184 0.0 29.000 0.534 Vel = 2.85 H.12 0.0 0.862 1 UeI 11.0 4.000 9.832 to 150.0 0.0 12.000 0.0 H.11 5.18 0.0184 0.0 16.000 0.294 Vel = 2.85 H.11 0.0 0.862 1 Utr 2.0 2.000 10.126 to 150.0 0.0 2.000 0.0 T.32 5.18 0.0182 0.0 4.000 0.073 Vel = 2.85 T.32 0.0 0.862 1 Utr 2.0 2.000 10.199 to 150.0 0.0 2.000 0.0 T.34 5.18 0.0185 0.0 4.000 0.074 Vel = 2.85 T.34 -1.92 0.862 2Utb 34.0 12.000 10.273 to 150.0 0.0 28.000 3.465 T.35 3.26 0.0078 0.0 40.000 0.312 Vel = 1.79 T.35 -0.82 0.862 1 Utr 2.0 1.000 14.050 to 150.0 0.0 2.000 0.0 T.33 2.44 0.0043 0.0 3.000 0.013 Vel = 1.34 T.33 0.0 0.862 1 Utr 2.0 2.000 14.063 to 150.0 0.0 2.000 0.0 T.31 2.44 0.0048 0.0 4.000 0.019 Vel = 1.34 T.31 1.68 0.862 2Utb 34.0 14.000 14.082 to 150.0 0.0 28.000 3.465 T.46 4.12 0.0120 0.0 42.000 0.505 Vel = 2.27 T.46 -1.94 0.862 1 Utr 2.0 6.000 18.052 to 150.0 0.0 2.000 0.0 H.22 2.18 0.0038 0.0 8.000 0.030 Vel = 1.20 H.22 0.0 0.862 1 UeI 11.0 2.000 18.082 to 150.0 0.0 12.000 0.0 T.45 2.18 0.0036 0.0 14.000 0.051 Vel = 1.20 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams • A-Pex Design Services, Inc. -EP Page 8 31 TOWNHOMES UNIT B' - Two Head Calculation (H.4 & H.3) Date 8/5/2015 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes ****** T.45 0.0 0.862 0.0 4.000 18.133 to 150.0 0.0 0.0 0.0 T.44 2.18 0.0038 0.0 4.000 0.015 Vel = 1.20 T.44 0.0 0.862 1 Utb 17.0 2.000 18.148 to 150.0 1 Utr 2.0 16.000 0.0 T.42 2.18 0.0037 0.0 18.000 0.067 Vel = 1.20 0.0 2.18 18.215 K Factor = 0.51 T.34 1.92 0.862 1 UeI 11.0 5.000 10.273 to 150.0 0.0 12.000 0.0 H.14 1.92 0.0029 0.0 17.000 0.050 Vel = 1.06 H.14 0.0 0.862 0.0 12.000 10.323 to 150.0 0.0 0.0 0.0 H.13 1.92 0.0029 0.0 12.000 0.035 Vel = 1.06 H.13 0.0 0.862 1 Utr 2.0 8.000 10.358 to 150.0 0.0 2.000 0.0 T.29 1.92 0.0029 0.0 10.000 0.029 Vel = 1.06 T.29 0.0 0.862 1 Utr 2.0 4.000 10.387 to 150.0 1 Utb 17.0 16.000 0.0 T.30 1.92 0.0030 0.0 20.000 0.059 Vel = 1.06 0.0 1.92 10.446 K Factor = 0.59 T.25 2.77 0.862 1 Utr 2.0 3.000 13.971 to 150.0 0.0 2.000 0.0 T.28 2.77 0.0058 0.0 5.000 0.029 Vel = 1.52 T.28 -1.67 0.862 2Utb 34.0 10.000 14.000 to 150.0 0.0 28.000 0.0 T.27 1.1 0.0011 0.0 38.000 0.040 Vel = 0.60 T.27 0.20 0.862 1 UeI 11.0 5.000 14.040 to 150.0 0.0 12.000 0.0 H.7 1.3 0.0014 0.0 17.000 0.024 Vel = 0.71 H.7 0.0 0.862 1Utr 2.0 7.000 14.064 to 150.0 0.0 2.000 0.0 T.37 1.3 0.0014 0.0 9.000 0.013 Vel = 0.71 T.37 0.81 0.862 2Utb 34.0 1.000 14.077 to 150.0 0.0 28.000 0.0 T.36 2.11 0.0035 0.0 29.000 0.101 Vel = 1.16 0.0 2.11 14.178 K Factor = 0.56 T.28 1.67 0.862 1 UeI 11.0 3.000 14.000 to 150.0 0.0 12.000 0.0 H.8 1.67 0.0023 0.0 15.000 0.034 Vel = 0.92 H.8 0.0 0.862 1 UeI 11.0 4.000 14.034 to 150.0 0.0 12.000 0.0 H.9 1.67 0.0022 0.0 16.000 0.036 Vel = 0.92 H.9 0.0 0.862 1 Utr 2.0 3.000 14.070 to 150.0 0.0 2.000 0.0 T.31 1.67 0.0024 0.0 5.000 0.012 Vel = 0.92 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams • A-Pex Design Services, Inc. -EP 31 TOWNHOMES UNIT B - Two Head Calculation (H.4 & H.3) Page 9 Date 8/5/2015 Hyd. Qa Ref. Point Qt Dia. Pf/Ft Fitting or Eqv. Ln. Pipe Ftng's Total Pt Pe Pf Pt Pv Pn Notes T.24 to H.2 0.0 1.67 0.20 0.2 14.082 K Factor = 0.45 0.862 150.0 0.0002 1 Utr 2.0 0.0 0.0 4.000 2.000 6.000 14.037 0.0 0.001 Vel = 0.11 H.2 to H.1 0.0 0.2 0.862 150.0 0.0 2UeI 22.0 0.0 0.0 10.000 24.000 34.000 14.038 0.0 0.001 Vel = 0.11 H.1 to T.27 T.35 to H.17 0.0 0.2 0.0 0.20 0.81 0.81 0.862 150.0 0.0001 1 Utr 2.0 0.0 0.0 12.000 2.000 14.000 14.039 0.0 0.001 Vel = 0.11 14.040 K Factor = 0.05 0.862 150.0 0.0006 1 Uel 11.0 0.0 0.0 7.000 12.000 19.000 14.050 0.0 0.011 Vel = 0.45 H.17 to H.16 0.0 0.81 0.862 150.0 0.0008 0.0 0.0 0.0 4.000 0.0 4.000 14.061 0.0 0.003 Vel = 0.45 H.16 to H.15 0.0 0.81 0.862 150.0 0.0006 1 Utr 2.0 0.0 0.0 10.000 2.000 12.000 14.064 0.0 0.007 Vel = 0.45 H.15 to T.37 T.46 to H.21 0.0 0.81 0.0 0.81 1.94 1.94 0.862 150.0 0.0006 1 Utr 2.0 0.0 0.0 8.000 2.000 10.000 14.071 0.0 0.006 Vel = 0.45 14.077 K Factor = 0.22 0.862 150.0 0.0030 1 Utr 2.0 0.0 0.0 6.000 2.000 8.000 18.052 0.0 0.024 Vel = 1.07 H.21 to T.43 0.0 1.94 0.862 150.0 0.0030 1 Uel 11.0 1 Utb 17.0 0.0 6.000 26.000 32.000 18.076 0.0 0.096 Vel = 1.07 0.0 1.94 18.172 K Factor = 0.46 T.38 to H.19 1.66 1.66 0.862 150.0 0.0023 1 Utr 2.0 0.0 0.0 1.000 2.000 3.000 18.117 0.0 0.007 Vel = 0.91 H.19 to H.18 0.0 1.66 0.862 150.0 0.0022 1 Uel 1 Utr 11.0 2.0 0.0 9.000 14.000 23.000 18.124 0.0 0.051 Vel = 0.91 H.18 to T.41 0.0 1.66 0.862 150.0 0.0022 1 Utb 17.0 0.0 0.0 8.000 14.000 22.000 18.175 0.0 0.049 Vel = 0.91 0.0 1.66 18.224 K Factor = 0.39 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 SUPPLY; STATIC P51: 60 RESIDUAL P51: 55 FLOW GPM: 300 20' OF 1-1/ 4" AQUAPEX MOM THE CPL TO 5.1 n 50' OF 1-1/ 4" POLY TOM THE METED — 5/ 8' METED � 1 15' OF 1!' COPPED FROM THE STP.EET Wt6gF SMI a 13F1"A11, N.T.S. CPL 1 NEAP 2 HEAP MO51 HYPPALICALLY DEMOTE HEAPS HEAD # GPM PrE5SUM DEQ' P AT STET H,12 13 47,18 1-1.4 & H3 18 52,2 0 ITC50-14 0 C;�C�O-12 O E49-16 PELIA3LE Model PFC30PFC30 Concealed Pendent Sprinkler 6 K. 155F`, 3/ 8" Orifice, Maximum Spacing 14'x14' Sprinkler head demand: 10 gpm @ 11.11 PELIPPLE Model PFC30PFC30 Concealed Pendent Sprinkler - - - 2 K-3, 155F', 3/ 8" Orifice, Maximum Spacing 12'x12' Sprinkler head demaid: 9 gpm ' 9 PELIAI3LE Model FC49PFC49 Concealed Pendent Sprinkler 14 K-4.9, 155F°, 3/ 8! Orifice, Maximum 5pacing 16'x16' Sprinkler head demand: 13 gpm @ 7,04 THIS 5UGGE5IEP LAYOUT 1513A5117 UPON INTONATION PPOVIDED FY OTHEPS, CHANGES IN CONSTPUCTION Ot; FIELD CONDITIONS MAY OCCUP WHICH MAY PEQUIPE CHANGES TO THE LAYOUT, IT 15 THE PESPONSIPILITY OF THE INS -FPI -LEP TO NOTIFY APEX DESIGN SERVICES OF SUCH CHANGES. CONCFA,tn Af7AP1Ef; MI -TING MOUN11NG 12�11Al. NFPA Iib 11A13L7,5, .5 NF A I5P 0.05.-15191:11N Fl:' I;�QUI MN15 n1511ANCFS TOM I-EA1 SOUPC-S 14.1.5. 8.6,3 ANP NTS SPPINKLEPS SHALL NOT [3E ITQUIMP IN CLOTI PANTIES THAT MEET ALL OF TIE FOLLOWING CONnI110N5: (I) THE AI?EA OF 11T SPACE Pas NOV EXCEEf7 24 (2) TIS LEAST f7IMENSION 170E5 NOT EXCEEC7 3 FT (3) TI -E WALL5 ANIS CEILINGS AIT 5U1MACEf7 WITH LIMITEP-COMPUME MAMMALS A5 PEFINEP IN TYPE5 OF PULPING CONSTPLICTlON, i 9 8 S CLOSETS, Ff2 (Z2 (0,9 M) NONCOMC3U511PLE NFPA 220, LINEN CLOSETS, M2) . , O1: 5fANnAPP ON a s " SCALE: 1/ 4!' - l'-0" �., ..,_1. NOAH EAKMAN 9 HEAP 50UPCE OFPINALN TEMP IN, INTEPMEC7IATE TEMP IN, rnonx EP i SIr7E OF FIREPLACE 36" 12" MWiMU M cur LENGTH Of PI MI NIM, MAXIMUM CUTLENGm Of pig i2 , FPONf OF FIMPLACE 60" 36" WOOP 13UPNING STOVE 42" 12" war N MANGE 18" 9' WALL OVEN 18" 9" ITOFEX ME N01 AIC? FLUES 18" 9" 5Pt /VAMP I'EAT PLICf5 18" 9"ir Ly 0 ,—UNINSULATEn ,fir "I ii, UNINSULA1EP HOT WATEk PIPES 12" 6" SIbE OF NOf AIP r71FFU5EP. Z4�� 12" \ � - FI:ONf OF Hof AIP PIFFUSEP 36" 18" - GLO CLO 12,6 SQ, FT ,,, \ q 0 25.8 SQ, Ff o K, 12 SQ, FT HOT WAV I EA7EC; 6" 3" FIELt7 VERIFY FINI51 DC7 FUC NACE 6" 3�� ' CEILING MATERIAL TO PETEPMINE MOUNTING I IGHf 171MEN5ION OW -250W LIGHT FIXTUM 6" 3" 5PPINKLEP Maar 5PPINKLEk ITQUl -t 5PPINKLEC; NOf I;EQUI1 n 250W -499W LIGHT FIXTURE 12" 6" Without Comments As Noteo in Rei Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Burez:u for conformance with current City :z<<.ndards. Accepuinci is subject to errors and missions which do r ut ?orize violations of adopted, :•ti,r:dards and ord'nrinces. The responsibility for the : r equacy of des n ;,<; _ rotal1y with the designer. Additions, detertior :ons to rhes drawings after this date wiii void =, <;r_Li !ce and will require a resubmitta c,'; r -. d--Fy, in ys for subsequent approv4 Final accepta:xia !s subjeci ;pieta test and Inspection The Tukwila -Fire Prevenvcr Su; -eau. Date: - / 5.,; f XJ1,5A-rviI I, -el 1. Hcdk veru -A. Nov./ l/ 2FC49-16 TUKWILA, t,A1ILA :-IRE DEPARTMENT MEN '" _.-_ r544Q7 and (J: r PE.F =.;!(f No. LCA shut- -pproval. rad �5f LOO 0 5" VALV, I-I/GIIAQUAP XFFOM AI\ 5Fi I \ KL, F F OOP 5.1 W"O N IOc I/ 4ll-I 5COhb LOO 0 �Io / I/ All_I i3011 COLO,?/ LINF1119F LEGFNt FLUE LINES- PEEP TO FIXTURES ( PATH, SHOWED, ETC) FLACK LINES- SPPINKLEP HEAP TO SPPINKLEP HEAP, 14— — 1/ 2!! PIPE 51ZE - 1" PIPE SIZE It> 1 I/ 4!! PIPE SIZE IF A PIN 1513F1NG IN51A.-LW, NO MOF THAN AN 8 P5I 191 55Ut 2t?OP A1' 26 GPM 15 tQUII t7, A 1" APOL1-0 OF 56HI,F 5 F1 5 PIN 15 FCOMMF VK -I84-200 2FY UPFIGH1" MU51" I3 IN51/,LI12 IN A1'11C IF FUFNAa 15 L.00A'2 Ot? 1 1,0 K-2 IN. Af1C CA-CIIA110N5 HAVE AI2 QUA'; SAfM 1'0 5UF POt1''-f A!II110NA. X11"11 \G. v_lop; I/ 411_1 I,OII PAID ii0 10 Mb TUKWILA FIRE DESI sJ FIFE 5F lkKLN:' 1073147th PI W Mukilteo, WA 98275 PH: 425-493-9680 FAX: 425-493-9717 SALES PEP: PE5112EN11AL FIFE PPOfEC11ON SYSTEM TUFF TYPE: 1/ 2" TO I-1/ 2" AQUAPEX 5PPINKLEP INFOPMA11ON # OF HEAPS 11H15 SHEET - 21 # OF HEAPS THI5 J013 - 21 STATIC PPE55UPE 15- 60 oo NZ PIELIM, & CONST, 8-5-2015 3 4 NO, I VISON/ 1551E 00 PROJECT #: 150805-02 COMPANY: CONTACT: MIKE OVEPFECK CONTACT PHONE # : 206-787-0259 SCALE: 1/ 4!' - l'-0" PESIGNEP 13Y: NOAH EAKMAN CHECKED PY: 00