Loading...
HomeMy WebLinkAboutPP - 12610 40TH AVE S - STEVENS RESIDENCE - PERMITS AND PLANS12610 40TH AVE S ASSOCIATED PERMITS 14-S-133 D11-334 257132,13 CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION King Co. Assessor's Tax No.: Site Address: 12610 40TH AVE S Suite Number: Floor: Tenant Name: New Tenant? ❑ - Yes ❑ - No Property Owner's Name: San Stevens Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Mike Hutchinson Day Telephone: Company Name: Evergreen Fire Protection Mailing Address: PO BOX 998 Puyallup 98371 City State Zip E-mail Address: Evergreenfireproamsn.com Fax Number: 253-252-7943 Valuation of Project (contractor's bid price): $ 3000.00 Scope of Work (please provide detailed information): new NFPA 13D fire sprinkler system PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: ..�` Signature: V � Date: 6/13/2014 Print Name: Mike Hutchinson Day Telephone: 253-381-4456 Plan Permit App.doc 5/14/10 TFD FP Form 8 INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER o n. l y -S �33 Del —33 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: e ST'�S '---2/Ls..el c2. Type of Inspection: 7 P ' - yUw-� "' '3="1'`'/� �JEt.1 Address: A Suite #: 12-(40‘0'tic S. Contact Person: Special Instructions: Pre -Fire: Phone No.: KApproved per applicable codes. Corrections required prior to approval. COMMENTS: is g /24-'� ,- itvii/41." z- 2- 11'7 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: a ,}i� Date: /l// Y Hrs.: / a $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy wit. permit 741-33 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: 5-YLAi S /0,ex/ C e 7 e Type of Inspection: S, -- &clry Address: Suite #: /Z6/0 - /D ' Ay Contact Person: Occupancy Type: Special Special Instructions: _c Phone No.: Approved per applicable codes. CO MENTS: Corrections required prior to approval. //-7 a'iv — ��'S5 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: ,;gy M Date: 7/z/ y Hrs.: /. 0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 bATE:"6/14/2014 C:\program files\HRS Systems\hhouse\Stevens tukwilla.rdfPage 1 EVERGREEN FIRE PROTECTION, INC. 10509 64th AVENUE E PUYALLUP,WA 98373 RESIDENTIAL SPRINKLER SYSTEM HYDRAULICS CALCULATION REPORT FOR Stevens residence Tukwilla 12610 40th Ave. S. Date: 6/14/2014 File No: Data File Name: Stevens tukwilla.rdf SPRINKLER SPACING 256.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 16.0 ft. Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall: 8.0 ft. SPRINKLER SPECIFICATIONS Mfr: 1 Reliable Descr: RA0612 RFC 43 / Fi Concealed Pend. (16x16) K=4.3 Calculated K Factor for Arm -Overs & Drops: 1.0 ft. x 1.101 in. Drop: K=4.26 (Incl. 1 Tee) 0.0 ft. x 1.101 in. Arm -Over: K=4.25 (Incl. 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC S-40 HWC: 150 WATER SUPPLY Source: Public Test Date: By: Static: 60.0 psi Resid: 0.0 psi Flow: 0.0 gpm Public Main Size: 0 in Domestic Demand: 0.0 gpm at node number 0 SPRINKLER DEMAND No.Spklrs. Min Spklr. Press. Node Total Avail. Req'd Flowing Flow (psi) No. Flow Press. Press. 1 13.0 9.3 1 13.0 60.0 32.2 2 13.0 9.3 1 26.3 60.0 41.7 REVIEWING AUTHORITY City of Tukwilla fill. PROTECTION $P INIR SYSTEMS I Michael D. Hutchinson 1100-060043G Level 2 Evsignsen Fl%roiection, Inc. i Ex�lr.. IDATE:"6/14/2014 C:\program files\HRS Systems\hhouse\Stevens tukwilla.rdfPage 1 EVERGREEN FIRE PROTECTION, INC. 10509 64th AVENUE E PUYALLUP,WA 98373 RESIDENTIAL SPRINKLER SYSTEM HYDRAULICS CALCULATION REPORT FOR Stevens residence Tukwilla 12610 40th Ave. S. Date: 6/14/2014 File No: Data File Name: Stevens tukwilla.rdf SPRINKLER SPACING 256.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 16.0 ft. Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall: 8.0 ft. SPRINKLER SPECIFICATIONS Mfr: 1 Reliable Descr: RA0612 RFC 43 / Fi Concealed Pend. (16x16) K=4.3 Calculated K Factor for Arm -Overs & Drops: 1.0 ft. x 1.101 in. Drop: K=4.26 (Incl. 1 Tee) 0.0 ft. x 1.101 in. Arm -Over: K=4.25 (Incl. 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC S-40 HWC: 150 WATER SUPPLY Source: Public Test Date: By: Static: 60.0 psi Resid: 0.0 psi Flow: 0.0 gpm Public Main Size: 0 in Domestic Demand: 0.0 gpm at node number 0 SPRINKLER DEMAND No.Spkirs. Min Spklr. Press. Node Total Avail. Req'd Flowing Flow (psi) No. Flow Press. Press. 1 13.0 9.3 1 13.0 60.0 32.2 2 13.0 9.3 1 26.3 60.0 41.7 REVIEWING AUTHORITY City of Tukwilla I CERTIFICATE OMPETENCY WASHINGTON STATE 1 i1RE PROiECTTlON SPRI SYSTEMS Michael D. Hutchinson 118G Level 2 &signo n Fire Protection, Inc. GFP96 LZ li EWE** DATE:'6/14/2014 C:\program files\HRS Systems\hhouse\Stevens tukwilla.rdfPage 2 PIPE & NODE DATA P # END LEN FIT. HWC NOD DIA EQV.LN RESULTS OF ANALYSIS FIXD LOSS EL SP PUMP (FT) (K) * * 1 sprinkler * *DISCH FLOW *(GPM) FL/FT * FLOW ANALYSIS flowing * 2 sprinklers flowing * PF PT *DISCH FLOW PF PT PE (PSI)*(GPM) FL/FT PE (PSI) * 1 1 16.00 LR ---- 20.0 4.26 13.0 -13.0 0.67 9.3 13.0 -13.0 0.67 9.3 150 3 1.101 6.0 ---- 20.0 ---- ---- -0.03 0.00 10.0 ---- -0.03 0.00 10.0 2 2 4.00 B ---- 20.0 4.26 ---- 0.0 0.00 10.0 13.3 -13.3 0.29 9.7 150 3 1.101 5.0 ---- 20.0 ---- ---- 0.00 0.00 10.0 ---- -0.03 0.00 10.0 3 3 28.00 L3B5R ---- 20.0 ---- ---- -13.0 1.63 10.0 ---- -26.3 5.97 10.0 150 4 1.101 25.0 ---- 20.0 ---- ---- -0.03 0.00 11.6 ---- -0.11 0.00 16.0 4 4 10.00 B ---- 20.0 ---- ---- -13.0 0.46 11.6 ---- -26.3 1.69 16.0 150 5 1.101 5.0 ---- 10.0 ---- ---- -0.03 4.33 16.4 ---- -0.11 4.33 22.0 5 5 6.00 LR ---- 10.0 ---- ---- -13.0 0.37 16.4 ---- -26.3 1.35 22.0 150 6 1.101 6.0 ---- 10.0 ---- ---- -0.03 0.00 16.8 ---- -0.11 0.00 23.3 6 6 10.00 L3R ---- 10.0 ---- ---- -13.0 0.55 16.8 ---- -26.3 2.03 23.3 150 7 1.101 8.0 ---- 0.0 ---- ---- -0.03 4.33 21.7 ---- -0.11 4.33 29.7 7 7 80.00 4L -10.0 150 8 1.598 28.0 ---- 0.0 ---- ---- -13.0 0.54 21.7 ---- -26.2 1.98 29.7 0.0 SRCE ---- 0.00 0.00 32.2 ---- -0.02 0.00 41.7 Legend: P - Pipe # DIA - Pipe Diameter EQV. LN - Pipe Equivalent Length PUMP - Pump Pressure SP - K -Factor FLOW - Flow Rate PF - Pressure Loss due to Friction PT - Total Pressure at Node Node Notes Pipe Notes LEN - Pipe Length FIT. - Pipe Fittings FIXD LOSS - Fixed Loss Device EL - Node Elevation DISCH - Discharge in gpm FL/FT - Friction Loss per Foot PE - Pressure Loss due to Elevation Fitting Code Letters: E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatVly, X= X, IDATE:-6/14/2014 C:\program files\HRS Systems\hhouse\Stevens tukwilla.rdfPage 3 The maximum velocity of water flow occurs in pipe 6 at 4.38 ft/s with 1 sprinkler flowing. The maximum velocity of water flow occurs in pipe 4 at 8.85 ft/s with 2 sprinklers flowing. PIPE FITTINGS TABLE Pipe Table Name: standard.npt PAGE: C MATERIAL: CPVC S-40 HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.101 1.00 5.00 5.00 1.00 1.00 8.00 2.00 0.00 0.00 0.00 1.598 2.00 7.00 8.00 1.00 1.00 14.00 3.00 0.00 0.00 0.00 Sprinkler system has been hydraulically calculated with the HASS HOUSE 3.2 computer program (License No. R609099990) to provide an average imbalance of 0.014 gpm at each node and a maximum imbalance of 0.11 gpm with one sprinkler flowing, and 0.013 gpm at each node and maximum imbalance of 0.10 gpm with 2 sprinklers flowing in accordance with NFPA 13 and 13D or 13R. HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 DATE:'6/14/2014 C:\program files\HRS Systems\hhouse\Stevens tukwilla.rdfPage 4 P R E S S U R E P S I 60.0 54.0 48.0 42.0 36.0 30.0 24.0 18.0 12.0 6.0 WATER SUPPLY CURVE A CB CD 0.0 1 1 + I 1 I 1 I 1 I 04 8 12 16 20 24 28 32 36 40 FLOW (GPM) Static = 60.0 psi (fixed pressure) (1 sprinkler flowing) (2 sprinklers flowing) A = Available Water Supply C = Available Water Supply 60.0 psi @ 13.0 gpm 60.0 psi @ 26.3 gpm B = Required Water Supply D = Required Water Supply 32.2 psi @ 13.0 gpm 41.7 psi @ 26.3 gpm Without Comments As Noted in Red Per The Attached Letter These pians have been reviewed by The Tukwila Fire ••r-^ventlon Bureau for conformance with current City ndards. Acceptance Is subject to errors and .1Issions which do not authorize violations of adopted andards and ordinar=c s. The responsibility for the adequacy of design resp: totally with the designer. Additions, deletions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance Is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: (--0 -1`( By: Aul iCol,,f,l/ c 4Aeci PL,Slfc wo-s o(.cfrt: 1. 44 hLydyo ret,;0e4t • Flow (6vA-1404-) re ciovej. Ihy11 e yI't��v+- -e(c tkrt 13e 1 f KWILA FIRE DEPARTMENT 'tease call 206-5754407 a • ve this Fire Permit Nos 11-1-S-111 nd exact address for shut- own hutown or restoration approve ST ASS 6.5.3 A warning sign, with minimum V4 inch letters, shall be affixed adjacent to the main shutoff valve and shall state the following: WARNING: The water system for this home supplies fire sprinklers that require certain flows and pressures to fight a fire. Devices that restrict the flow or decrease the pressure or automatically shut off the water to the fire sprinkler system, such as water softeners, filtration systems, and automatic shut- off valves, shall not be added to this system without a review of the fire sprinkler system by a fire protection specialist. Do not remove this sign. HANGER INSTALLATION REQUIREMENTS MAXIMUM DISTANCE BETWEEN HANGERS ' NOMINAL PIPE SIZE 3/4' 1' 1-1/4' 1-1/2' Y 2-1/r 3' 4' 6' BLAZEMASTER CPVC 5' 6' 6' 0' 6' 6' 7' 0' 8' 0' 9' 0' 10' 0' N/A N/A THREADABLE UGHTWAU. N/A 12' 0' 12' 0" 12' 0' 12' 0' 12' 0" 12' 0' N/A N/A STEEL PIPE (10/ 40) N/A 12' 0' 12' 0' 15' 0' 15' 0' 15' 0" 15' 0' 15' 0' 15' 0' ALL PIPE TO BE 1"CPVC UNLESS OTHERWISE NOTED. PIPE INSULATION INSULATION TENTING DETAIL 6.2421 SL 10'-8" 111 3/16" 0 5D 2412 FX 3'-7 13/16" N q 26$ f 1 IAI.1.G. d4 SCI SOAKING TUB 5Q 21 SL 3' 4" L'tttx,DM #4 3'-2" L ►•i 51-U" \l. LOFT UP FROM M FLOOR u' 4) - BEDROOM #2 BEDROOM #3 512421 SL O 1. 5Q4'2i 5L .�- 5'--11/2" 51-1 1/2" 5'-6" J 1 111-3" 10'-q" 221-0" n 11� L 4:t N 4'-0" -u- a4 4Y 111, 4 SHOWER. 5'-10" OPEN TO BELOW 18'-0" 40'-O" UPPER FLOOR PLAN SCALE lie m. \ \ \ O m \ \ \ N \ \ 9 414414 lSL 4144,4 I51_ I 6-1 FAMILY q' CLC. DIRECT VENT 6AS FIREPLACE APPLIANCE INSTALL PER MFR. TO UPPER FLOOR • 1 HR. DOOR W/ SELF CLOSER a m 5'311 I5L 11) GF}- j L 1 ISLAND KITGHEN � w z� 0517 10'-z j _ /DESK 3'-8" tri o • DINING q' GLG. IC -5014 ARCH W/ 6" SFRING 2A 1 8" PVC COLUMN W/ MFR. GAP 8 BASE PDR SOcfm .ate �el 4 ' 1/4 LARGII i, / PARALLAM �� 1ti / 3024 ARCH q " SPRING W/ 6" SPRING 41) GFI 5/8" TYPE -X GYPSUM / WALLBOARD ON ALL / WARM WALL 4 (2) LAYERS ON CEILING/ 131-0" STRAP H1►T WATER T TO 18" A ' ORM-* HT.'S EL. BOLLA 31_5" 052 36"\GUARDRAIL Z\ 3'-6" 46 1 21-4" 4" CONG. 5 B FLOOR;gd.d 0' a` „tvi h �am, {) ate, SPRINKLER RISER GARAGE <> GARF.GE DOOR OPENER ...... .......' �� `` -� � 5 I/4"xx18, P���L1 ARLA _ I/2"x11 1/8" PARALLAM FLUSH LIVING c1.' GLG. 2 i' �' 16'x8' OHD ` i-/ \�� 211 11'-0" 22'-0" 11'-O" 61-511 A / 2'-8" , 2'-8" 011-11"/ 1'-11"/ 15' -IO" 18'-0" 40'-O" LO R FLOOR PLAN SCALE 1/4" - 1' 7320005 406E 1190 510404414 425 01.1.75 11-30 00203071 W� 600 61100E» W 041.0110 P3/97 VT COX 041,16. 030 'SEAr446 461E0 N' 04.6. 02.0 71330107 177.144 . 4 02. • 7100 FE1111315 105 2LPS -0 1111161104 446 014. 42 LeM1 16100 creams 1.0.040 0087 0' 8.1010 P33104 r-i9iE 108.13010105•24.02. 1/2'cox (01;e•ChB 964340006124 HA • 'i =.OS 0132442113)ME• D 14031E7,0 0-43 76114.1104 F0 244 1-316. 207504 724130344. 5.� 431 CL.- 6131,,,,011 ! V2 NI 1!D' PAPALLAH 503301 .R M 044.741391340770 ELS 44110 W X06' 02.. 00.0 FE1 1430.,WD63 Al 2410' Fl.9ls0S-t VI' 63796 N4.LB04.0D TP/ 20014.1114/ STUDS • N' 02. 41.2.7431..15?.• K• 02. PE4MIL 1e' 613344 NOLLEO200 V1•a11 1/611330.31.1.314 044 MCP M.P. R-10 1EI171011 Nit 10PMRK RAO 6611.4.001 1010.34.4 23B41/0 1111=1'..;.,-. 2 51. 712410,5 4'41201PGT P45 242 ries (rrn1 3/4, T. 644.718134 • 424 HA 1IX1. 6.' 02. OL. 10 ES < 10• Oo. 0 71E17.52-5E17.52-5OGELD 717013376--% 417.4 2.12 F1.. 157 • K' 04. 2.6 HAIL W SRO' • 16.01.. 631516 YVIL1111 20(7019 400 7634. . 021 G. FF21.01.00.14 4.0 0F. •.76FiV1 O,P. 4.6 FOES TP) 5106 304 LQG. P40 General Notes 6,0,3 . 000 &GET 0e EA 501E (RP) 1116 30,001.. PAD SECTION "AA" =Li. 1m -re 1. OWNER TO PROVIDE ADEQUATE HEAT (40'F. MIN) TO PREVENT SPRINKLER PIPES FROM FREEZING. 2. OWNER TO PROVIDE HARD WIRED HOME SMOKE DETECTION SYSTEM. 3. CPVC PIPE SHALL HAVE HANGERS 6'-0" c\c AND NOT MORE THAN 6" FROM ANY SPRINKLER HEAD. 4. ALL ATTIC PIPING TO BE TENTED WITH BATT INSULATION TO PREVENT FREEZING. 5. ALL PIPING TO BE 1" C.P.V.C. U.N.O. 6. A 6" BELL TO BE LOCATED ON THE EXTERIOR APPROACH TO HOME IF REQUIRES BY THE LOCAL A.H.J. 7. IF A OUTLET FOR A FUEL FIRED APPLIANCE IS PIPED ON AN EXTERIOR COVERED DECK A INTERMEDIATE TEMP. DRY SPRINKLER WILL BE INSTALLED. 464. 1010. 34610.6 30•• LPG. P40 Sprinkler Symbol Legend ® SPRINKLER ORIFICE SIZE, TYPE & FINISH RELIABLE RFC 43 16'x16' 2 head flow requirement 26 GPM ® 9.6 psi RELIABLE F1 RES 49 16'x16' FLOW REQUIREMENT 26 GPM ® 9.6 psi QUAN 25 TEMP 155' 155' K FACTOR 4.9 4.3 111 RELIABLE F1 RES 44 SIDEWALL 16 X 20' VICTAULIC DRY UPRIGHT 155' 200' 4.3 5.6 Reliable F 3 QR DRY Sidewall 155' 5.6 TOTAL 26 WATER FLOW INDICATOR PRESSURE GAUGE Spare sprinkler head cabnet SARIN NTS EVERGEE\ FRE POTECTION PO BOX 998 Puyallup, WA 98371 EVERGFP967LZ Phone: (253) 252-7942 INC. DATE: 6 /9/2014 REV: I DRAWN: MH I SHEET: 1 OF1 TO SYSTEM DRAIN VALVE STATIC WATER PRESSURE 60 pal DRAIN PIPED TO EXTERIOR AMES 2000B BACKFLOW PREVENTER To domestic piping • 14' 1.5" 80' LER RISE Sheet Title 1" WATER METER c \FDA 13 STEV �S Stamp D Fig ESI CERIMI A.JCr FIRE PROTECTION SIPIREAKUSS SYSTEMS !Michael D. Hutchinson 11188 -0599 -BG Level 2 Evergreen Fire Protection, Inc. EVERGFP967 PLAN \CE Job Title 1X610 /10T- AV- S. PAID T < WI LLA, WA. jUN lrz 2014 uKwiLA ARP cc 179'