Loading...
HomeMy WebLinkAboutPP - 4060 S 144TH ST - TUKWILA SCHOOL DISTRICT - PERMITS AND PLANS4060 S 144TH ST ASSOCIATED PERMITS 18-F-023 I$-F-o2� CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** 11-746 SITE LOCATION 1523049013 King Co. Assessor's Tax No.: Site Address: 4060 S 144th St Tukwila, WA 98168 Suite Number: Floor: Tenant Name: Tukwila School District New Tenant? ❑ - Yes - No Property Owner's Name: Tukwila School District Mailing Address: 4060 S 144th St Tukwila WA 98168 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Eric Hamerski Day Telephone: 206-436-5315 Company Name: Washington Alarm Mailing Address: 2030 Airport Way S E-mail Address: permits@washingtonalarm.com City State Zip Fax Number: 206-322-7214 Contractor's City of Tukwila Business License number: BUS -0992857 Total number of new/relocated devices or sprinkler heads: 52 + FACP & AES Valuation of Project (contractor's bid price): $ 8,000 WAInc to provide parts/smarts installation of a fire alarm system in a remodeled no sprinkled Scope of Work (please provide detailed information): group B facility. Installation to include automatic detection, manual initiation, HVAC detection, and occupant notification. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY _. AWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNEAGENT: Signature: Date: 1/18/2018 Print Name: Ma ny Ornelas Day Telephone: 206-436-5301 Plan Permit App.doc 8/22/14 TFD FP Form 8 Tukwila Fire Prevention Bureau Al Metzler, Fire Project Coordinator Fire Prevention Bureau Review Memo Date: Project Name: Address: Permit #: Plan Reviewer: January 24, 2018 Tukwila School District Transp/Maintenance 4060 S 144 St. 18-F-023 Al Metzler, Fire Project Coordinator The Fire Prevention Bureau conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. 1. Heat detectors in interstitial space to be 190 degrees fixed temperature. 2. Above ceiling heat detectors to have remote LED's on ceiling. 3. Exterior Weatherproof horn/strobe to face direction of fire department access. 4. Install a breaker handle clamp on dedicated fire alarm circuit breaker. 5. Fire alarm circuit breaker to be labeled in red. 6. Install "Fire Alarm Panel" sign on door to room containing fire alarm panel. Should there be questions concerning the above requirements, contact the Fire Prevention Bureau at 206-971-8718. No further comments at this time. TUKWILA SCHOOL DISTRICT -TRANS/MAINTENANCE FIRE ALARM SYSTEM SHEET INDEX FA0.1 GENERAL NOTES, CODE INFORMATION, SYMBOL LIST FA0.2 FIRE ALARM SYSTEM: FACP DETAIL, TYPICAL DEVICE DETAIL FA0.3 FIRE ALARM SYSTEM: SYSTEM CALCULATIONS, MATRIX, RISER FA1.1 FIRE ALARM SYSTEM: MAIN FLOOR PLAN, INTERSTITIAL PLAN CODE/PROJECT INFORMATION Bartell Drugs Riverton 110 11416 Soars Super Saver roods OWNER: V L, I•:1 f., lark et the tiro th $ 1dllh ^I Southgate Mobile Monte Palk t;,1 4060 South 144th Street Tukwila Pool TUKWILA SCHOOL DISTRICT, TUKWILA, WA ARCHITECT: GENERAL CONTRACTOR: ROLLUDA ARCHITECTS, SEATTLE, WA ELECTRICAL ENGINEER: TRES-WEST, TACOMA, WA G 14(ah (tl PROJECT SITE JB CONSTRUCTION CONSULTING, SEATTLE, WA ELECTRICAL CONTRACTOR: TAX ID/PARCEL: SYSTEM SOLUTIONS, LYNNWOOD, WA 1523049013 FIRE ALARM AUTHORITY: CITY OF TUKWILA PROJECT BUILDING PERMIT: D17-0227 OCCUPANCY: CLASS: B LOAD: <300 CODES: CONSTRUCTION -AREA OF WORK: TYPE: VB SPRINKLED: NO CITY OF TUKWILA MUNICIPAL CODE: CHAPTER 16 - 16.04, 16.40 IFC (2015ed) NPFA72 (2016ed) WAC 51-54A-0907 SCOPE RESPONSIBILITIES: WASHINGTON ALARM TO FURNISH/INSTALL ALL EQUIPMENT SHOWN (UNLESS NOTED), INCLUDING INITIATION & NOTIFICATION DEVICES. SYSTEM SOLUTIONS TO FURNISH/INSTALLALL RACEWAY, BACKBOXES, WIRE AS REQUIRED. SYSTEM SOLUTIONS TO FURNISH 120VAC POWER. SEE ALSO EL18-0039, EL18-0040 PROJECT DESCRIPTION: REPLACE AND MODIFY EXISTING AUTOMATIC AND MANUAL FIRE ALARM SYSTEM WITH NEW IN CONJUNCTION WITH REMODEL. FULL AUTOMATIC DETECTION, FULL MANUAL INITIATION, AND FULL NON -VOICE OCCUPANT NOTIFICATION. FIRE ALARM PATHWAY CLASS DESIGNATIONS: NOTIFICATION APPLIANCE CIRCUIT(S): B SIGNALING LINE CIRCUIT(S): B SURVIVABILITY: 0 (NONE REQUIRED) COMMUNICATION METHOD: EXISTING COMMUNICATION METHOD TO BE RETAINED IN ACCORDANCE WITH NFPA72 (2016ed) 26, BY WASHINGTON ALARM, 206.328.3288. UL: 110698-001 SECONDARY POWER SUPPLY CALCULATION 1. NOT ALL GENERAL NOTES MAY BE IN EFFECT FOR THIS INSTALLATION AND SCOPE OF WORK. 2. PER IFC (2015ed) 907.1.3, ALL WIRE AND DEVICES CONNECTED TO THE FIRE ALARM SYSTEM SHALL BE LISTED BY AN APPROVED LISTING AGENCY (TYPICALLY UL OR FM,) COMPATIBLE, AND INSTALLED PER MANUFACTURER'S SPECIFICATIONS AND INSTRUCTIONS. INSTALLATION SHALL BE IN ACCORDANCE WITH ALL AUTHORITIES HAVING JURISDICTION (AHJ), NFPA, IFC, NEC, WAC, MUNICIPAL CODE, AND CONTRACT DOCUMENTS. 3. INSTALLING CONTRACTOR(S) SHALL PROVIDE WASHINGTON ALARM WITH A LEGIBLE, CLEAN, AND ACCURATELY NOTED DRAWING FOR "AS BUILT" PURPOSES. THE DRAWINGS SHALL INCLUDE PERTINENT WIRE RUNS, CONDUIT SIZES/LOCATIONS, JUNCTION BOXES, SIGNIFICANT DEVICE LOCATION CHANGES, MOUNTING HEIGHTS THAT DIFFER FROM LISTED HEIGHTS, AND 120VAC POWER CIRCUIT PANEL LOCATIONS/CIRCUIT NUMBERS. 4. PROTECTED PREMISES FIRE ALARM (NFPA72, 2016ed: 3.3.103.4.2) SYSTEMS SHALL BE MONITORED BY A LISTED SUPERVISING STATION (NFPA72, 2016ed: 3.3.280/3.3.281) IN ACCORDANCE WITH IFC (2015ed) 907.6.6. COMMUNICATION METHODS SHALL BE IN ACCORDANCE WITH NFPA72 (2013ed/2016ed) 26.6. COMMUNICATION VIA DACT (2 "POTS" LINES) ALONE IS NOT ACCEPTABLE WITHOUT APPROVAL BY ALL AHJ 'S PER NFPA72 (2013ed) 26.6.3.2.1.4, OR NFPA72 (2016ed) 26.6.4.1.4. MONITORING MAY BE SUBJECT TO DEFERRED CONTRACT, AND MAY BE PERFORMED BY OTHERS BEYOND THE CONTROL OF WASHINGTON ALARM. 5. ALL 120VAC WIRING TO CONTROL UNITS AS DEFINED BY NFPA72 (2013ed) 3.3.59, 3.3.102, 3.3.199 OR NFPA72 (2016ed) 3.3.60, 3.3.100, 3.3.196 SHALL BE PERMITTED (SEPARATELY IF REQUIRED BY AHJ AND INSTALLED BY AN ELECTRICAL CONTRACTOR LICENSED TO PERFORM SUCH WORK. ALL 120VAC WIRING TO CONTROL UNITS AND POWER SUPPLIES SHALL BE DEDICATED, LABELED, AND INSTALLED WITH A BREAKER LOCK. ALL CONTROL UNITS AND POWER SUPPLIES SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF WASHINGTON ALARM STAFF. ALL 120VAC WIRING ENTERING FIRE ALARM CABINETS SHALL BE THROUGH DEDICATED KNOCKOUTS, AND SHALL MAINTAIN A MINIMUM OF 0.25" SEPARATION FROM POWER LIMITED/LOW VOLTAGE WIRING. 6. THIS PROJECT MAY EMPLOY A SEPARATE ELECTRICAL CONTRACTOR AND FIRE ALARM CONTRACTOR IN A JOINT VENTURE. UNLESS OTHERWISE NOTED BY ANY CONTRACT DOCUMENTS, THE ELECTRICAL CONTRACTOR SHALL PERMIT (SEPARATELY, IF REQUIRED BY THE AHJ), FURNISH AND INSTALL ALL BACKBOXES, RACEWAY, AND WIRE PER WASHINGTON ALARM SPECIFICATIONS. ELECTRICAL CONTRACTOR SHALL INSTALL ALL SPECIALTY BACKBOXES, ENCLOSURES, FIRE ALARM TERMINAL CABINETS PROVIDED BY WASHINGTON ALARM. PLEASE ALLOW FOR A MINIMUM TWO WEEK LEAD TIME ON ALL WASHINGTON ALARM SUPPLIED EQUIPMENT. 7. WIRING SHALL BE PER DESIGN WITH RESPECT TO CONDUCTOR SIZE AND/OR CABLE TRAY. TYPE, QUANTITY, COLOR CODE AND CONDUCTORS SHALL BE PERMANENTLY AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. ELECTRICAL CONTRACTOR SHALL MAINTAIN THE CLEANLINESS OF ALL INSTALLED BOXES/ENCLOSURES. DIRT/DEBRIS SHALL BE CLEANED PRIOR TO TRIM. 8. WIRING SHALL CUT FOR IN/OUT. WIRING SHALL NEVER BE LOOPED THROUGH DEVICES, ALL SPLICED WIRE POSSESSING SHIELD SHALL HAVE SHIELDS SPLICED AND TAPED TO PREVENT GROUND FAULTS. 9. WIRING SHALL RUN CONTINUOUS FROM SOURCE TO FIRST DEVICE ON CIRCUIT THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACKBOXES OF DIFFERENCT CIRCUITS. "T -TAPPING" OF CONVENTIONAL INITIATION (IDC'S) OR NOTIFICATION APPLIANCE CIRCUITS (NAC'S) WILL RESULT IN A NON FUNCTIONAL SYSTEM, AND IS STRICTLY PROHIBITED. 10. WIRING SHALL BE METERED AND VERIFIED TO BE CONTINUOUS, FREE FROM GROUND, SHORTS, OR ANY OTHER FAULT $. 11. WIRING SHALL BE IN CONDUIT, OR CONCEALED/HIDDEN. SURFACE MOUNT WIRING INSTALLATION ALLOWABLE WHEN.APPROVED BY OWNER, OWNER REP., OR PROJECT TEAM AND COMPLIANT WITH ADOPTED CODES. 12. NUMBERS ADJACENT TO NOTIFICATION SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS, AND NOTIFICATION SETTING:EXAMPLE DEVICE SC1-9 WOULD BE NINTH DEVICE ON SIGNAL CIRCUIT 1. 30CD DENOTED CANDELA RATING SETTING. NOTIFICATION CIRCUIT WIRING IS SUPERVISED. PARALLEL BRANCHING IS NOT PERMISSIBLE. 13. WALL MOUNT SIGNALLING APPLIANCES SHALL BE INSTALLED PER THE HEIGHTS LISTED BY THE SYSTEM DESIGNER/WASHINGTON ALARM IN ORDER TO ACHIEVE CURRENT COMPLIANCE AS WELL AS POTENTIAL MANUFACTURING DESIGN CHANGES IN THE FUTURE. COMPLIANCE WITH NFPA72 (2013ed/2016ed)18.5.5 WHERE THE ENTIRE LENS OF STROBE IS NOT LESS THAN 80" AND NOT GREATER THAN 96" ABOVE FINISHED FLOOR. SEE ALSO NFPA72 CHAPTER 18 FOR LOW WALL HEIGHTS, OR CEILING MOUNTING INSTALLATIONS. 14. DO NOT DEVIATE FROM CIRCUIT RUNS SHOWN ON PLANS WITHOUT PRIOR APPROVAL FROM SYSTEM DESIGNER/WASHINGTON ALARM. SYSTEM SHALL BE INSTALLED WITH MINIMUM 20% SPARE CAPACITY (SUBJECT TO ADDITIONAL CONTRACT REQUIREMENTS) PER IFC (2015ed) 907.5.2.3.1. FACTORS SUCH AS EXCESSIVE VOLTAGE DROP, ENGINEERING, ADDITIONAL COMPONENTS, ETC... SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR DICTATING AS BUILT ROUTING. 15. NOTIFICATION APPLIANCES SHALL PRODUCE AN AUDIBILITY OF NOT LESS THAN 15dB ABOVE THE AMBIENT NOISE LEVELS AND REMAIN IN COMPLIANCE WITH WASHINGTON STATE ADMINISTRATIVE CODE (WAC) 51-54A-0907. NON VOICE SYSTEMS SHALL SOUND IN THE STANDARD TEMPORAL THREE PATTERN AT THE LOWEST DECIBEL SETTING (90dB) UNLESS OTHERWISE NOTED ON PLANS. ALL VISUAL DEVICE CANDELA RATINGS ARE DETERMINED IN ACCORDANCE WITH NFPA72 (2013ed/2016ed) 18.5.5.4. 16. ALL DEVICES SHALL BE ACCESSIBLE OR MADE ACCESSIBLE (BY WAY OF HATCH, CATWALK ABOVE CEILING GRID, REMOVABLE PANELS) FOR ALL CURRENT AND FUTURE INSTALLATION, TESTING OR MAINTENANCE REQUIREMENTS. ACCESSIBILITY SHALL BE IN ACCORDANCE WITH NFPA72 (2016ed) 3.3.1 - 3.3.4. 17. ANY POST CONTRACT ISSUANCE CHANGES TO CONSTRUCTION, INCLUDING THE LOCATION AND TYPE OF WALLS, CEILINGS, PERMANENT FIXTURES MAY AFFECT DESIGN, AND SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE SYSTEM DESIGNER/WASHINGTON ALARM, AS A RE -REVIEW BY ALL AHJ'S MAY BE REQUIRED. 18. SMOKE DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIR -FLOW, NOR CLOSER THAN 36" FROM AN AIR SUPPLY DIFFUSER. 19. DO NOT INSTALL SMOKE DETECTOR HEADS UNTIL FINAL CLEANING, OR IF UNPRACTICAL DUE TO CONSTRUCTION SCHEDULES, SMOKE DETECTORS SHALL BE PROTECTED FROM CONSTRUCTION DUST AND OTHER ENVIRONMENTAL CONCERNS. 20.ALL DETECTORS SHALL BE RATED FOR THE TEMPERATURE AND ENVIRONMENT FOR THE LOCATION IN WHICH THEY ARE INSTALLED. 21.FOR THE PURPOSE OF THIS INSTALLATION, SPRINKLER MONITORING AND FIRE ALARM ARE INTERCHANGEABLE AND EQUAL. SEE SCOPE/PROJECT NARRATIVE. SYMBOL LIST - PERTINENT TO THIS SCOPE OF WORK TUKWILA, WASHINGTON QUANTITY SYMBOL DESCRIPTION 1 4 MANUFACTURER MODEL BACKBOX MOUNTING HEIGHT NOTE FAC P FIRE ALARM CONTROL PANEL FIRELITE MS96000DLS PROVIDED BY FIRELITE 66" A.F.F. TO TOP FAA FIRE ALARM ANNUNCIATOR FIRELITE ANN80 FIELD DETERMINE AT EXISTING FAA CONDITIONS F FIRE ALARM MANUAL PULL FIRELITE BG12LX EXISTING CONDITIONS TO REMAIN 23 PHOTOELECTRIC 'Op 3 FIRELITE AD355 4S DEEP W/1G RING CEILING DUCT MOUNT � SMOKE DETECTOR FIRELITE D355PL N/A FIELD VERIFY 12 FIXED TEMPERATURE OF HEAT DETECTOR FIRELITE AS REQ. 3 3 7 1 1 H355 4S DEEP W/1G RING CEILING ADDRESSABLE SINGLE FIRELITE OUTPUT MODULE CRF300 FIELD VERIFY FOR USE WHERE NEEDED HVAC SHUTDOWN 740: - REMOTELY LOCATED TEST SWITCH SYSTEM SENSOR RST151 4S DEEP W/1G RING )2( )2( ,‘ NOTIFICATION STROBE ONLY CEILING MOUNT NOTIFICATION HON. /STROBE CEILING MOUNT NOTIFICATIONp� WE�QO WEATHERPROOF NOTIFICATION HORN/STROBE END OF LINE RESISTOR SYSTEM SENSOR SWL 4S DEEP W/1G RING LOCATE IN USER SERVICEABLE LOCATION 84" A.F.F. TO CENTER SYSTEM SENSOR P2WL SYSTEM SENSOR PC2WL 4S DEEP W/1G RING 4S DEEP W/1G RING 84" A.F.F. TO CENTER CEILING SYSTEM SENSOR P2RK PROVIDED BY SYSTEM SENSOR 92" A.F.F. TO CENTER 0 Without Comments 16 As Notea in Red IS Per The Attached Letter These plans have been reviewed bv The Tukwila Fire Prevention Bureau for conformance w th current City standards. Accepta ,c3 is aup_jecf rrors and ornissions vvhicz, rr( r101.:;;lithorize '.;lo?atiorrs of adopted standards anci rhe iT:soorrsibility for the adequacy or des,r:,,; rotally with Me designer. Additions, deletion, : i:visions to these drawings after this date wi+.l t io to, .--.eptance and Mil require a resubmittai ala r, Arlt r: ,'; v iritis for subsequent approval. Final acceptance ,.ioJecr co field test and inspection by The Tukwila Fire Prevention Bureau. Date: /-,,41-- l Bv: .5) I WIRE DESIGNATIONS TUKWILA FIRE DEPARTMENT Please call 206-575-1407 anu giv ? this Fire Permit No. -F- and F„rind exact address for shut- down hutdown or W:t11.4,Z7 WIRE DESIGNATION SYM DESCRIPTION D SLC/DATA ADDRESSABLE LOOP T THHN-GENERAL USE Sx SIGNALLING CIRCUIT #TBD L REMOTE TEST NUMBER OF CONDUCTORS 2 AS PART OF SAME CABLE 1 2 AS PART OF SAME CABLE 6 SIZE 16 14 14 14 TYPE FP LR/FPLP THHN FPLR/FPLP THHN COLOR CODE RED (JACKET) FIELD DETERMINE RED (JACKET) FIELD DETERMINE e IN FRONT OF LETTER SIGNIFIES CIRCUIT CABLE IS EXISTING IN NATURE - VERIFY = HASH MARK QUANTITY SIGNIFIES QUANTITY OF DESCRIBED WIRE ALL WIRE PERMITTED, FURNISHED, AND INSTALLED BY ELECTRICAL CONTRACTOR AS LISTED ON 'THIS PAGE. EACH TYPE OF CIRCUITRY SHALL BE UNIQUELY AND LOGICALLY LABELED. ANY CHANGES SHALL BE SUBJECT TO APPROVAL BY BOTH WASHINGTON ALARM, AND ELECTRICAL ENGINEER LISTED ON THIS PAGE. PAID JAN 18 2O1 TUKWILA FIRE c- WASHINGTON ALARM P: 206.328.3288 2030 Airport Way S Seattle, WA, 98134 www.washingtonalarm.com WA Lic: WASHIAI282C3 P: 425.249.2076 PO Box 5308 Lynnwood, WA, 98046 www.systemsolutionwa.com WA Lic: SYSTESW900PD Project Title TECHNOLOGY & MAINTENANCE SERVICE CENTER TUKWILA SCHOOL DISTRICT #406 4060 S 144TH ST TUKWILA, WA, 98168 Project Numbers 17266-1 Issue & Revision Dates 15 JAN, 2018 INITIAL DESIGN SUBMITTAL TO A/E Sheet Title FIRE ALARM NOTES, CODE INFO, SYMBOL LIST, WIRE DES. Drawn By EH Checked By Sheet Number FAO.1 ® 2017/2018, WASHINGTON ALARM SC2 TO EXISTING ( SC2 TO EXISTING (+)S SC1 TO SC1-1 ( )S SC1 TO SC1-1 (+)S AUX POWER (+) TO ANN80S AUX POWER (+) TO ANN80S AC POWER (L1)S EARTH AC POWER (L2)S s E c 0 N D A R Y P H 0 N E L E G O G G O ® O O me + - BATTERY FIRELITE MS96000LDS DETAIL SCALE: NONE STO ANN80 TERMINAL 3 STO ANN80 TERMINAL 4 SDATA TO FIELD (+) SDATA TO FIELD (—) SK—MOONITOR/SK—MONITOR2 ADDITIONAL SET OF CONTACTS AVAILABLE ONS DUAL INPUT OR UTILIZED FORS CLASS A WIRING NON—POWERED DEVICE,S EX. WATERFLOW, TAMPER, WITH 47k EOL RESISTORS T10 T9 T8 T7 T6 U SDATA/SLC (—) IN DATA/SLC (+) IN TENS ONES O 0 2 TYPICAL ADDRESSABLE INITIATION MODULE DETAIL SCALE: NONE NOTE: INDOOR CONFIGURATION ONLY. SHOULD DEVICE REQUIRE SURFACE MOUNTING, NOTIFY WASHINGTON ALARM IMMEDIATELY, AS TO PROVIDE DEVICE SPECIFIC SURFACE MOUNT BACKBOX. s>+ O 0 4S DEEP, WITH SINGLE GANG RING 84" A.F.F. TO CENTER CDTYPICAL MOUNTING: WALL NOTIFICATION DEVICE SCALE:NONE AUTOMATIC INITIATION DEVICE DATA/SLC (+) INS DATA/SLC (—) IN DEFAULT DETECTOR BASE -r—SDATA/SLC (+)TO NEXT -DATA/SLC (—)TO NEXT CAUTOMATIC INIT. DEVICE DETAIL -STANDARD BASE SCALE: NONE WASHINGTON ALARM P: 206.328.3288 2030 Airport Way S Seattle, WA, 98134 www.washingtonaiarm.com WA Lic: WASHIAI282C3 P: 425.249.2076 PO Box 5308 Lynnwood, WA, 98046 www.systemsolutionwa.com WA Lic: SYSTESW900PD Project Title TECHNOLOGY & MAINTENANCE SERVICE CENTER TUKWILA SCHOOL DISTRICT #406 4060 S 144TH ST TUKWILA, WA, 98168 Project Numbers 17266-1 Issue & Revision Dates 15 JAN, 2018 INITIAL DESIGN SUBMITTAL TO A/E Sheet Title FIRE ALARM TYPICAL DEVICE, FACP DETAILS Drawn By EH Checked By Sheet Number © 2017/2018, WASHINGTON ALARM SYSTEM DEVICE MATRIX Address Dev Type Response Description/Type M001 M002 M003 M004 005-027 M028 M029 M030 031-099 Address BG12LX BG12LX BG12LX BG12LX Unused CRF300 CRF300 CRF300 Unused Dev Type Fire Fire Fire Fire n/a n/a n/a n/a n/a Response Break Rm Pull Maintenance Rm Pull SE Training Rm Pull Main Entry Pull Not Used Reserved: AHU TBD Shutdown Reserved: AHU TBD Shutdown Reserved: AHU TBD Shutdown Not Used Description/Type 5001 S002 S003 S004 S005 S006 S007 S008 S009 5010 5011 5012 S013 5014 5015 5016 5017 S018 5019 S020 S021 S022 S023 S024 S025 S026 5027 S028 5029 S030 5031 S032 S033 `-S034 5035 S036 S037 S038 039-099 AD355 AD355 AD355 AD355 AD355 AD355 AD355 AD355 AD355 AD355 AD355 AD355 AD355 AD355 AD355 AD355 AD355 H355 AD355 H355 AD355 AD355 AD355 AD355 AD355 H355 H355 D355PL D355PL D355PL H355 H355 H355 H355 H355 H355 H355 H355 Unused Fire Fire Fire Fire Fire Fire Fire Fire Fire Fire Fire Fire Fire Fire Fire Fire Fire Fire Fire Fire Fire Fire Fire Fire Fire Fire Fire Su prvsy Suprvsy Suprvsy Fire Fire Fire Fire Fire Fire Fire Fire n/a SYSTEM RESPONSE MATRIX FACP Area Smk Kitchen Smk Break Rm Smk Maintenance Rm Smk Open Office N Smk Open Office Ctr Smk Open Office S Smk NW Office Smk N Ctr Office Smk NE Office Smk Receiving Area Smk Work Area N Smk Work Area SW Smk Work Area SE Smk Main Hall Smk MDF Rm Smk SW Office Smk Custodial Heat Ctr Training Rm Smk Ctr Training Rm Heat Conference Rm Smk Main Entry Smk Mens R/R Smk Womens R/R Smk SE Training Rm Smk SE Storage Heat SE Storage Heat AHU TBD Duct Smk AHU TBD Duct Smk AHU TBD Duct Smk Open Office NW Interstitial Heat Open Office NE Interstitial Heat Open Office SW Interstitial Heat Open Office SE Interstitial Heat Work Area N Interstitial Heat Work Area S Interstitial Heat R/R Interstitial Heat SE Training Interstitial Heat Unused OPERATIONS MATRIX HOURS IF ABLE ONBOARD FACP REMOTE ACTIVATE AUDIBLE/VISUAL NOTIFICATION CIRCUITS: ALL DEACTIVATE AUDIBLE/VISUAL NOTIFICATION CIRCUITS: ALL SIGNAL TO REMOTE CENTRAL STATION TYPE: ALARM SIGNAL TO REMOTE CENTRAL STATION TYPE: SUPERVISORY SIGNAL TO REMOTE CENTRAL STATION TYPE: TROUBLE SIGNAL TO REMOTE CENTRAL STATION TYPE: RESET PERFORM SYSTEM RESET REVERSE/RESET ALL STATES TO NORMAL LOCAL ANNUNCIATION AT FACP AND/OR FAA NOTE 1: AC FAIL DELAY 3-6 NOTE 2: SYSTEM WILL TRANSMIT NOTE 3: IN ADDITION TO ACTIVATE ASSOCIATED INDICATOR INPUT OUTPUT ANY AREA SMOKE DETECTOR: SMOKE DETECTION X X X ANY AREA SMOKE DETECTOR: TEMPERATURE <135°F X X X ANY FIXED HEAT DETECTOR: TEMPERATURE <135°F X X X ANY MANUAL PULL STATION ACTIVATION X X X ANY DUCT SMOKE DETECTOR: SMOKE DETECTION X 3 ALARM STATE: SILENCE BUTTON PRESSED X X ALARM STATE: RESET BUTTON PRESSED X X COMPONENT/DEVICE TROUBLE, OPEN CIRCUIT SHORT ON NAC CIRCUIT WIRING X X COMMUNICATION FAIL/TROUBLE 1 X AC FAILURE 2 X VOLTAGE DROP CALCULATIONS SECONDARY POWER SUPPLY CALCULATION NE NE x WORST CASE VOLTAGE DROP CALCULATI❑N * E SECONDARY POWER SUPPLY CALCULATION w JOB NAME: CIRCUIT: AREA SERVED: DATE PERFORMED: 2 H/S: 1 H/S: 1 H/S: 1 H/S: 1 STR: TSC -TSMC SC1 = FACP OUTPUT 1 TRAINING/❑PEN OFFICE 2017-12-22 P2WL P2WL PC2WL P2RK SWL (15CD) AT 0. 044 AMPS EACH = (75CD) AT 0. 111 AMPS EACH = (75CD) AT 0. 137 AMPS EACH = (75CD) AT 0, 157 AMPS EACH = (75CD) AT 0. 107 AMPS EACH = 0. 088 AMPS 0, 111 AMPS 0. 137 AMPS 0, 157 AMPS 0. 107 AMPS TOTALS = 0.600 AMPS CIRCUIT LENGTH = 190" TO END WIRE SIZE = #16 AWG CIRCUIT LDAD = 0. 600 AMPS RESISTANCE = 4. 489 0ii000 CALCULATIONS PERFORMED IN ACCORDANCE WITH NFPA72 (2016ed) 10,3.5 SUPPLY LISTED OPERATING VOLTAGE = 24.0 --> 85% - 20.4 DEVICE OPERATING VOLTAGE = 16.0 - 33,0 TEMPERATURE = 122°F TOTAL WIRE RESISTANCE = ((WIRE LENGTH) *2) /1000 * (RESISTANCE/FT) TOTAL WIRE RESISTANCE - ((190*2) /1000) * 4. 489 = 1, 705 VOLTAGE DROP = ( CKT, LOAD) * ( TOTAL WIRE RESISTANCE) VOLTAGE DROP - O, 600 NE 1. 705 = 1, 023 VOLTAGE AT EOL = (OPERATING VOLTAGE) - (VOLTAGE DROP) VOLTAGE AT EOL - 20. 4 - 1, 023 = 19, 377 NOTE: CALCULATED TO 16GA, 14GA IS ACCEPTABLE FOR USE, *****************************************?*********************** WORST CASE VOLTAGE DROP CALCULATION ) * SIE * SIE SIE SIE SIE SIE SIE SIE * * SIE SIE SIE * SIE SIE SIE SIE SIE * SIE SIE SIE SIE SIE * SIE SIE SIE SIE SIE SIE SIE * SIE SIE SIE * * SIE * * SIE SIE SIE SIE * SIE SIE * SIE SIE SIE SIE * SIE * SIE * SIE SIE SIE * SIE SIE SIE * JOB NAME: TSC -TSMC CIRCUIT: SC2 = FACP OUTPUT 2 AREA SERVED: DATE PERFORMED: 2017-12-11 2 H/S: P2WL 1 H/S: P2WL 1 H/S: P2WL 2 STR: SWL (15CD) AT 0, 044 AMPS EACH = (30CD) AT 0. 065 AMPS EACH = (75CD) AT 0. 111 AMPS EACH = (15CD) AT 0. 043 AMPS EACH = 0. 088 AMPS 0. 065 AMPS 0. 111 AMPS 0. 086 AMPS TOTALS = 0.350 AMPS CIRCUIT LENGTH = 400" TO END WIRE SIZE = #16 AWG CIRCUIT LDAD = 0. 350 AMPS RESISTANCE = 4. 489 D,i000 CALCULATIONS PERFORMED IN ACCORDANCE WITH NFPA72 (2016ed) 10.3.5 SUPPLY LISTED OPERATING VOLTAGE = 24.0 --> 85% - 20.4 DEVICE OPERATING VOLTAGE = 16.0 - 33,0 TEMPERATURE = 122°F TOTAL WIRE RESISTANCE = ((WIRE LENGTH) *2) /1000 NE (RESISTANCE/FT) TOTAL WIRE RESISTANCE - ((400*2) /1000) NE 4. 489 = 3. 591 VOLTAGE DROP = ( CKT. LOAD) NE (TOTAL WIRE RESISTANCE) VOLTAGE DROP - 0. 350 * 3. 591 = 1. 256 VOLTAGE AT EOL = (OPERATING VOLTAGE) - ( VOLTAGE DROP) VOLTAGE AT ELL - 20. 4 - 1. 256 = 19, 144 NOTE: EXISTING WIRE CALCULATED AS 16GA, MAXIMUM CIRCUIT LENGTH AT THIS LOAD IS 1120' NOTE: SUBJECT TO FIELD VERIFICATI❑N, PERCEIVED WORST CASE SCENARIO JOB NAME: PANEL: L❑CATION: DATE PERFORMED: TSC -TSMC SPRINKLER MONITORING CONTROL PANEL ELECTRICAL AREA 2017-12-11 QTY. DEVICE INF❑ QUICENT( A) ALARM( A) 1 FACP: MS9600 1 FCC: DACTUD2 1 FAA: ANN80 3 MOD: CRF300 4 PULL: BG12LX 23 SMK: AD355 3 SMK: D355PL 12 HT: H355 1 MAXIMUM SLC1 ALARM DRAW 1 NAC: SC1 1 NAC: SC2 0, 1030 0. 0170 0, 0150 0. 0009 0. 0012 0, 0069 0. 0009 0. 0036 N/A 0. 0000 0. 0000 0. 1030 0. 0290 0. 0400 N/A N/A N/A N/A N/A 0. 4000 0, 6000 0. 3500 TOTALS = 0. 1485 QUICENT LOAD = 0.149 AMPS QUICENT TIME = 24 HRS. QUICENT = 3.576 AMP*HRS TOTAL = QUICENT + ALARM = 3. 576 + 0. 381 = 3. 957 AMP*HRS DE -RATING FACTOR OF 25% ---> 3. 957 * 1. 25 = 4. 947 * SIE * SIE SIE * * SIE SIE SIE SIE * * * SIE * * SIE SIE * SIE SIE * SIE * * * * SIE * SIE SIE * SIE SIE SIE SIE * SIE SIE * SIE SIE * SIE SIE SIE SIE SIE 1. 5220 ALARM LDAD = 1.522 AMPS ALARM TIME = 0. 25 HRS, ALARM = 0.381 AMP*HRS INSTALL 2 * MINIMUM BATTERY SIZE = 4.95 AMPERE*H❑URS * SIE SIE * * * SIE SIE * * SIE SIE SIE SIE * * SIE SIE SIE SIE SIE SIE SIE SIE * * SIE SIE SIE SIE * SIE SIE SIE * * SIE SIE SIE SIE SIE SIE * SIE SIE * SIE SIE * SIE * 12V 7AH BATTERIES RISER DIAGRAM eD (E) DATA CIRCUIT INTERSTITIAL ©p L ©p L eD eS S1 S(E) DATA CIRCUIT eD fle li © iJOF S008 S009 S010 S006 S020 S019 eD P S005 S(E) SIGNAL CIRCUIT. LOCATE EOL AND REPLACE (E) DATA CIRCUIT 0 FACP FIRELITE MS9600 eA S1 0 S1 si 0 S1 si SC1-1 SC1-2 SC1-3 SC1-4 SC1-5 SC1-6 DEDICATED 120V CIRCUIT FAA FA -1 LEVEL 1 D S021 WASHINGTON ALARM P: 206.328.3288 2030 Airport Way S Seattle, WA, 98134 www.washingtonalarm.com WA Lic: WASHIAI282C3 11,111111111111111111, - OF / P: 425.249.2076 PO Box 5308 Lynnwood, WA, 98046 www.systemsolutionwa.com WA Lic: SYSTESW900PD Project Title TECHNOLOGY & MAINTENANCE SERVICE CENTER TUKWILA SCHOOL DISTRICT #406 4060 S 144TH ST TUKWILA, WA, 98168 Project Numbers 17266-1 Issue & Revision Dates 15 JAN, 2018 INITIAL DESIGN SUBMITTAL TO A/E Sheet Title FIRE ALARM CALCULATIONS, RISER, MATRIX Drawn By EH Checked By Sheet Number FAO.3 Q 2017/2018, WASHINGTON ALARM 65'-7 1/2" (E) 17'-8" (E) REPLACE EXISTING FIRE ALARM PANEL SC1-1 75CD ELEC. 111 BREAK RM 112 MAINT/STOR. 113 47'-11 1/2" (E) OFFICE 115 OFFICE 116 j OFFICE 117 7- L F KIT 110 WORK ROOM 109 1 0 REX5\ 5002` OFFICE 108 RFX S012 EX CIRCUIT `-� STO REMAIN REX 5013 1 150a D I MDFT1 109A REX 30CD REX S017 REX S004 `REX 5011 RECEIVIr G 106 REX S018 r %/ REX S014 EX CIRCUIT TO REMAIN S1 1 50081 5009 EX CIRCUIT TO REMAIN OPE (FICE � I I 41 � I I 1 1 y--1-1 1 I Sc1-3' 7:; soo -0 D 50101 Of,L LL I I LJ REX wPS007 1-1 I I 1 L. HALLWAY 105 REX 5015 Cf. CUSTODIAN 107 ENTRY LOBBY 17'-8" (E) 100 SC1-6 75CD T .71 S SC1-5 75CD REX 5022 REX 15CD REX S023 O MEN 101 A REX I=1 2 S020 STORAGE 119 CONFERENCE EX CIRCUIT TO REMAIN S021 120 L J REX REX 15CD S024 WOMEN 102 REX v-ItS026 REX 75CD STORAGE 104 REX REX 5025 TRAINING ROOM 103 EI REX M003 1 47'-11 1/2" (E) 7 65'-7 1/2" (E) L FIRE ALARM -- MAIN FLOOR SCALE: 1/8" = 1' PROJECT NORTH w N N N 0) C1-21 N N a) w a 0) N w_ CV 9 10 W 00 N 7/ 17'-8" (E) 65'-7 1/2" (E) FIRE ALARM & ARA - SYSTEM NOTES 1 0 -WIRING IS SHOWN POINT TO POINT ONLY. ELECTRICAL AND/OR FIRE ALARM CONTRACTOR SHALL ANNOTATE ALL WIRE RUNS, CONDUIT SIZES, EOL LOCATIONS, AND OTHER SYSTEM INFORMATION TO FACILITATE ACCURATE AS BUILT DRAWINGS. 1-INTECEPT NEAREST PRACTICAL DEVICE, OR HOME RUN DATA TO FACP. 2 -REMOVE EXISTING SMOKE DETECTOR, MAINTAIN CIRCUIT INTEGRITY. PROVIDE COVER PLATE AS REQUIRED. 3 3 -IF AVAILABLE, ISOLATE DEVICE SC1-1 AS A DEDICATED CIRCUIT. 47'-11 1/2" (E) f REXTF REX S035 REX S029 L TO REMOTE TEST, LOC ON GRID CEILING, FIELD DETERMINE REXTf REX 5036 REX S028 L± 0 REMOTE TEST, LOC N GRID CEILING, FIELD DETERMINE 17'-8" (E) REXC REX 5031 REX(R S033 REXTFf, REX 5032 REX(R S034 REX S030 L TO REMOTE TEST, LOC ON GRID CEILING, FIELD DETERMINE REX. REX S037 REX6. REX S038 f 47'-11 1/2" (E) 65'-7 1/2" (E) PROJECT NORTH FIRE ALARM -- MAIN FLOOR INTERSTATIAL SCALE: 1/8" = 1' w N r CV rn WASHINGTON ALARM P: 206.328.3288 2030 Airport Way S Seattle, WA, 98134 www.washingtonalarm.com WA Lic: WASHIAI282C3 .: i . ; d ; 1 :., (. ,•., f . C` t'? r-. i()1•Z P: 425.249.2076 PO Box 5308 Lynnwood, WA, 98046 www.systemsolutionwa.com WA Lic: SYSTESW900PD Project Title TECHNOLOGY & MAINTENANCE SERVICE CENTER TUKWILA SCHOOL DISTRICT #406 4060 S 144TH ST TUKWILA, WA, 98168 Project Numbers 17266-1 Issue & Revision Dates 15 JAN, 2018 INITIAL DESIGN SUBMITTAL TO A/E Sheet Title MAIN FLOOR FIRE ALARM Scale: 1/8"=1' Drawn By EH Checked By Sheet Number FA1.1 © 2017%2018, WASHINGTON ALARM