FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
Site Address: 6452 S 144TH ST
Tenant Name:SEALANT SPECIALISTS
King Co. Assessor's Tax No.: 336590-1810
Suite Number: Floor:
New Tenant? ❑ - Yes ® - No
Property Owner's Name:LOUIE SANFT
Mailing Address:6120 52ND AVE S SEATTLE WA 98118
City State Zip
CONTACT PERSON -if there are questions about the submittal.
Name: DENNIS COATES Day Telephone:(360) 491-6320
Company Name:ALARM CENTER, INC.
Mailing Address:PO BOX 3407 LACEY WA 98509
City State Zip
E-mail Address:dcoates(alarmcenterinc.com Fax Number:(360) 438-4244
Contractor's City of Tukwila Business License number: BUS -0992830
Total number of new/relocated devices or sprinkler heads: 1
Valuation of Project (contractor's bid price): $450.00
Scope of Work (please provide detailed information): INSTALL NEW A.E.S. FIRE ALARM COMMUNICATOR AND
CONNECT TO EXISTING DMP XRS FIRE ALARM CONTROL UNIT.
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDINGNER OrTHORIZED AGENT:
r.,.
Signature:
Date: 05/28/2015
Print Name: DENNIS COATES Day Telephone: (360) 481-4969
Plan Permit App.doc
8/22/14 TFD FP Form 8
- 1/ s riii7
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with pe it
POS1 E9.
Dz.-3(S
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila, Wa. 98188 206-575-4407
Project:Type
(�, 'r �-�
of Inspection:
gQ�t.. �ri-t L
,, ii-gz-c..\-,�.__
Address:Contact
Suite #: 5Z Si (4/4--C--6
Person:
Special Instructions:
Phone No.:
I 60.1
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
19*, -k k;(t6L
Needs Shift Inspection: yes
Sprinklers: x'45
Fire Alarm: i -
Hood & Duct:
Monitor:q kd•‘c AA
Pre-Fire: ¶40A
Permits: 'cL f4*i t&
`�)
Occupancy Type: 5-1
Inspector: a
j
i
Date:
yt« tt.3
Hrs.:
V
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip
Word/Inspection Record Form.Doc
6/11/10
T.F.D. Form F.P. 113
1
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with p
0/c- s/S
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila, Wa. 98188 206-575-4407
Project:Ty
5e_AlAnk SPece,+(t-s4.
Sprinklers:
of nspection:
Address: 6015-4-
Suite #:
5 /q4-(7-___
Contact Person:
Special Instructions:
Occupancy Type:
Phone No.:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
4A,(c_
0.12d
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector: ,
c
Date:
h. /,j
Hrs.:
/
r
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word/Inspection Record Form.Doc
6/11/10
T.F., D. Form F.P. 113
City of Tukwila
Fire Department
FIRE WATCH REQUIRED
Due to the inoperative fire protection system(s) in your facility, you are required to provide a fire watch
per City of Tukwila Ordinance #2437, section 16.40.120-D and Ordinance #2436, section 16.42.100-C
(see reverse side). The fire watch shall be maintained until the system(s) are operational as determined
by the Tukwila Fire Marshal's Office. FAX paperwork to 206-575-4439 to verify the completion of
repair work and/or the restoration of system monitoring, in order to end the fire watch.
The fire watch is required 24 hours a day. Designated employees may serve as the fire watch during
business hours, while performing their regular job. Fire watch personnel must be aware of, and accept
the duties of the fire watch.
After hours fire watch personnel must be on location and must patrol the building following the close of
business. Every two hours they must call 206-971-8737 and leave a message stating the following:
1. Your name.
2. Street address of firewatch location.
3. Time of day.
4. If everything is OK, state all clear. If you discover an emergency during your patrol , call
9-1-1 immediately to report it.
Date: l Obi/ S
Reason For Fire watch:
Inspectors:
Zrd14---, 1.+/le/2m,- /Clam
Start time:
« Oc,eL,"---
Incident #:
Business Name: -5er'ri ,Cie -10 ST.s
Business Address:
Business Phone: 24 G it 2. trSLy
hkPerson in Charge: 21,-541^ Signature:
W — Fire Marshal's Office Y — Owner/Manage
Rev. 7/29/14
%d /5<_ / /17/O %rS e'i 6L in441 15 kC
T.F.D. Form F.P. 41
Tukwila Fire Marshal's Office • Phone: 206-575-4407 • Fax: 206-575-4439 • Email: FireMarshal@tukwilawa.gov
ACE FIRE
& SECURITY
SYSTEMS
A DIVISION OF ALARM CENTER, INC.
05/28/2015
CITY OF TUKWILA
COMMUNITY DEVELOPMENT DEPARTMENT
PERMIT CENTER
6300 SOUTHCENTER BLVD., SUITE 100
TUKWILA, WA 98188
ATTN.: FIRE MARSHAL
RE: A&B Properties
Sealant Specialists (John Latta Associates)
6452 South 144th St.
Tukwila, WA 98168
ACCEPTED
❑ Without Comments
72( As Noteo >>, Reti
❑ Per Me =ttacted Letter
plans have been reviewed by The Tukwila Fire
.:-ration Bureau for conformance with current City
• +arils. Acceptance: is subject to errors and
:;ons which do cot at..ithort2e ,i(slatio :7f. adopted
:nils ana ordinances. 'T e '-esuons'bk:: nor the
:.,icy of design rests totaii,, rr rr•.e lesigner.
deletions revisions: e as;awings after
bate wilt. voi0 t.►3:, acceptatgr'^' quire
udbmlttai of revised. drawings f': r:.4 pproval.
f tai acceptance is subject to field test. anti Inspection by
e Tukwila Fire Prevention Bureau.
Date: 4'/ I C By:
Sl I
iE ea404. Sti.oke•de4-. ciSovc A -ES/ Fi4c?
E-svrc brrvLt• Ara.%c..�..(
Ace Fire and Security Systems, a UL listed fire and security alarm installation and maintenance
company, submits the following description of work that will be done at the above listed location.
Scope of Work
Install an A.E.S. fire alarm communicator. Product is UL Fire and NFPA-72 compliant, and has built-in
power supply and charger. Communicator will be connected to a DMP XRS fire alarm control unit.
Point of contact: Dennis Coates, dcoatesalarmcenterinc.com, 360-491-6320 or 800-354-1555.
Dennis Coates
dcoates@alarmcenterinc. corn
TUKWILA FIRE D PA T ;EVi
Please call 206-575-44.07 and
give this Fire Pp��� AL=, Fire- '6.
Secant.
err j kr 4.500 Thin_- Ave.,_. 93503 it Nil
6 F : (36C 436-4244 a Phone: --800-3-54-165
and exact add ss for shut
bwn or restoration approval.
PAID
MAY 282015
TUKWILA FIRE
z 3,ov—
k�6¢6¢
77i y,914/77
e RF Subscriber Unit
UL Fire, AA Burglary and NFPA-72 Compliant
UL Listed
UL Listed Central
Station
Remote Station
864 Ed. 9, 827, 1610,
365, 681
CSFM
NFPA
RF Section 8.6.3.5
Advanced Wireless Alarm Monitoring
The 7744/7788 smart subscriber unit links an alarm panel to an
alarm monitoring central station. This 2 -way transceiver and
repeater in one is housed in a full size locking steel cabinet for
superior performance. The 7744/7788 supports a wide range of
inputs such as NO/NC/EOL and direct voltage. It automatically
senses wire and antenna cuts, and monitors battery and AC
power status. Advanced status reporting, self -diagnostics and a
built-in power supply make the 7744/7788 the first choice for all
wireless alarm communication needs.
Full Data for Fire and Burglary
Use with the optional Firetap for full fire data or the IntelliTap for
full fire and burglary data.
AvailablerConfigurations
7744 — 4 reversing
polarity inputs plus 4
programmable EOL inputs
7788 — Programmable EOL
inputs with 8 zones
Available'a
ions
FireTap 7770
IntelliTap 7067
NEMA 4 Enclosure
High Gain Antenna
Additional Back Up Battery
Available in Burglary Beige
or Fire Red
•
'73e ' of
CORPORATION 9 For Alarm tylorAonnq
• Options for Full Data for
Fire and Burglary
• Available in 7744 & 7788
Zone Configurations
• Built-in Power Supply
and Battery Charger
• Local Annunciation
Options on Board
Wireless mesh networking is an
innovative technology adopted by
many industries with applications
that need to communicate data over
a large geographic area with a high
level of reliability at a low total cost
of ownership.
The advanced design and 2 -way
communications capability provides
easy installation, expansion, and
management when compared to
alternative communication methods,
both wired and wireless.
RF Subscriber Unit
Technical Specifications
Radio
Standard CSAA frequency ranges:
450-470 MHz and 130-174 MHz, VHF
and UHF. Others available
Standard Output Power
2 watts (requires FCC license)
Power Input
16.5 VAC, 40VA UL listed
Class II transformer required
Voltage
12 VDC nominal
Current
175mA standby; 800mA transmit
Alarm Signal Inputs
• 4 individually programmable Zones:
NO/NC/EOL, trouble restore
• RS -232
• Reversing voltage (7744 only) 12 or
24 VDC
Operating Temperature Range
0° to 50°C, 32° to 122°F
Storage Temperature Range
-10° to 60°C, 14° to 140°F
Relative Humidity Range
0-85% RHC non -condensing
Back up Battery
12V, 7 AH
Low Battery Reporting
22.5 -minute test cycle
AC Status
Reports to central station after
approximately 60 minutes without AC
power, reports power restored after
approximately 60 minutes of restored
power. programmable from 60 to 180
minutes
Antenna Cut (local reporting)
Form 'C' Contact 1 AMP
Size
13.25"H x 8.5"W x 4.3"D
34cm x 21.5cm x 11 cm
Weight
6.4 lbs, 2.9 Kilograms
(excluding battery)
Colors
Available in standard
Burglary Beige or Fire Red
Please specify when ordering
Available Options
• 7788 RF subscriber unit
with 8 EOL inputs
• 7744 RF subscriber unit with 4 EOL
inputs and 4 reverse polarity inputs
• 7770 - FireTap
• 7067 - IntelliTap
• NEMA 4 Enclosure
Please specify when ordering
AES-IntelliNet " is the industry leader in delivering high quality wireless mesh
networks to the fire and security industry in commercial. corporate. government.
and educational applications with its broad line of products and advanced network
management tools. Users of AES-InteiliNet networks have gained significant rev-
enue. communications, and cost advantages while meeting the nigh standards of
reliability required for the fire and security industry. AES-IntelliNet alarm monitoring
systems are deployed at hundreds of thousands of locations in over 130 countries.
to31.07>* rneic
CORPORATION I For Alarm Monitoring
For more information
Call 800 -AES -NETS (800-237-6387)
AES Corporation 1285 Newbury Street 1 Peabody, MA 01960 USA
Tel. +1 978-535-7310 I Fax +1 978-535-7313 I Email info@aes-intellinet.com
Web www.aes-intellinet.com
Available configurations
• 7788, 8 EOL inputs
• 7744, 4 EOL inputs w/4
reverse polarity inputs
Copyright 2008 AES Corporation
AES-IntelliNet is a registered trademark of AES Corporation
7744/7788/02/08
•
CORPORATION
yr SECURITY
INNUVAT10
1 Data Modules for Fire Subscribers
Intell Pro Firet"' Series
About AES Corporation
Established in 1974, AES
Corporation empowers
companies to grow profitable
alarm monitoring businesses,
and government agencies to
enhance security anywhere
in the world. By providing
the industry's only patented
operator -owned and controlled
private wireless mesh networks,
AES ensures superior reliability,
low TCO and optimal RMR while
reducing dependence on service
provider infrastructures.
The company's flagship
AES-IntelliNet systems are
deployed in over a half million
locations worldwide.
Features
Meets UL 864
Commercial Fire Alarm
requirements for primary
standalone communication
Drop-in full function
replacement for phone
lines in commercial fire
alarm systems
Transmits full alarm event
data from FACP digital dialer
to AES-MultiNet receiver
AES Subscribers are the ideal
universal wireless alarm
transmitters supporting all
new and legacy FACPs
AES-lntelliPro Fire modules easily
install in AES Subscriber
Minimal programming
needed converting
phone line connections to
AES-IntelliPro Fire
w
Ks .o
7795
UL 864 Listed for Primary
Standalone Alarm Communication
from Fire Subscriber
7794
UL 864 Listed for Supplemental
Alarm Communication with
Fire Subscriber
Ideal Replacement for Phone Lines
AES-lntelliPro Fire"' Series full data modules with AES Fire Subscribers provide the ideal
drop-in full -function replacement for phone lines to communicate signals from UL
commercial fire alarm systems. AES-IntelliNet network owner -operators retain virtually
100% of the Recurring Monthly Revenue (RMR) generated from network services.
Replacing phone lines with AES-IntelliNet technology maximizes RMR profit because,
unlike with AlarmNet-A or cellular technologies, there are no service charges paid to a
third -party network provider. In addition, with AES-IntelliNet there is zero risk of fire alarm
communication technology sunset as with all past, present, and future
cellular technologies.
Primary Standalone Communication for Fire Alarm
The AES-IntelliPro 7795 product meets UL 864 and NFPA-72 requirements for primary
standalone alarm communication by simply moving the Fire Alarm Control Panel (FACP) .
phone line output connections to the AES-lntelliPro Fire Series module installed in a Fire
Subscriber. No other connections are needed between the FACP and the Subscriber. The
AES 7794 product meets UL requirements for supplemental communication when used
with consolidated alarm, trouble, and supervisory signals triggered by FACP outputs
connected to Subscriber zone inputs.
•
• Technical Specifications
7794
• Transmits full data to
AES-MultiNet receiver using
Contact ID or Pulse formats
Formats Supported: Contact
ID, Pulse 3+1, Pulse 4+1, Pulse
4+2, Modem Ile, and
Modem II1a2
I/O CONNECTIONS
• AES subscriber - data
and power
• Handheld/PC
programming port
• Plain Old Telephone Service
(POTS) incoming phone line
• Phone output connection
from alarm panel
• Trouble output (form C relay)
SIZE
• 47/3 in. x 5 in, (12.3 cm x 12.7
cm) Power Requirements
• 12 VDC nominal, primary and
backup power provided by the
AES RF Transceiver Unit
Current Consumption 350
rnA nominal
7795
The 7795 AES-IntelliPro is a
kit that includes the 7794
module and 7762 Hardware
Supervisory module. *For model
7794, please see Technical
Specifications above
The 7762 is a Hardware
Supervisory Module.
I/O CONNECTIONS
• )1 - AES 7794 02) or Subscriber
(J1)- data and power
Input for Subscriber J4 Output
• Input for AES 7740 Local
Annunciator - data and power
• AES 7740/AES 7794 Trouble
Output to Subscriber
input zone
SIZE:
2 1/2 in. x 4 15/16 in.
(6.3 cm x 12.5 cm)
WEIGHT:
• 0.25 pounds (0.11 kilograms)
POWER INPUT:
• 12VDC nominal, power
supplied from AES 7794
module or AES
7744F/7788F Subscribers
CURRENT CONSUMPTION
• 40 mA average; 100 mA peak
Full Alarm Signal Data
No alarm data is lost converting fire alarm signals from over Public Switched
Telephone Network (PSTN) to transmission over AES-intelliNet alarm communications.
AES IntelliPro Fire Series modules transmit full alarm data captured off the FACP's digital
communicator including alarm zone identification and event codes. AES-IntelliPro Fire will
work in new fire alarm system installations to substitute phone line connections as well
as retrofit existing installed fire alarm systems. AES-IntelliPro Fire supports most alarm
communication protocols including Contact ID, Pulse, and Bosch Modem Ile and
Modem IIla2.
Flexible Installation Options
Existing installed Subscribers can easily be
upgraded to communicate full alarm data
from a FACP's digital dialer over AES-IntelliNet
networks. For these applications, models
7794 and 7795 are available as field installed
modules that come with all needed hardware
to upgrade an existing AES Subscriber. For
new installations, AES Fire Subscribers are
available equipped with the right AES-IntelliPro
Fire module for the application.
Acld- ��l ArES /nt /!IPro 1LIIes
7794 AES-lntelliPro Fire Full Data Module. UL listed for supplemental
communication with fire radios
7795 AES-Incel/iPro Fire Full Data Module (7794) with 7762 Hardware Supervisory
Module. UL listed for primary standalone communication with fire radios
eFii Fire Subs:c fibers equipped c.i_h AE n e// Pro Fri e
7744F-ULP
7788F-ULP
7744F-ULP-P
7788F-ULP-P
7788F-C-ULP
4x4 Zone Fire Subscriber, 4 Reversing Polarity, 4 Supervised, includes
7794 AES-lntelliPro Fire, Red Enclosure
8 Zone Fire Subscriber, 8 Supervised Zones, includes 7794 AES-IntelliPro
Fire, Red Enclosure
4x4 Zone Fire Subscriber, 4 Reversing Polarity, 4 Supervised, includes
7795 AES-IntelliPro Fire, Red Enclosure
8 Zone Fire Subscriber, 8 Supervised Zones, includes 7795 AES-IntelliPro
Fire, Red Enclosure
8 Zone Fire Subscriber with 7794 AES-IntelliPro Fire, Red Enclosure
(ULC) Canada
Hardware Supe
col l�
7762 Add-on module provides power/supervision for 7794 AES-IntelliPro Fire
module and AES 7740 local trouble annunciator. Included with 7795
AES-IntelliPro Fire and AES 7742 local annunciator kit for Subscriber
Specifications Subject to Change Without Notice
LISTED
us SI Qs-A,ii
NFPA®
NetOne