Loading...
HomeMy WebLinkAboutPP - 3425 S 146TH ST - ROOF CORPORATION OF WA - PERMITS AND PLANS3425 S 146TH ST ASSOCIATED PERMITS 19-F-045 10-F-080 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Site Address: 3425 S 146th St Tenant Name: Fresh & Green Produce Market New Tenant? aYes ❑ - No Property Owner's Name: Roof Corp. of WA Mailing Address: 2130 S Dupont Dr. Anaheim, CA 92806 **PLEASE PRINT** King Co. Assessor's Tax No.: 0040000827 Suite Number: Floor: 1 s t CONTACT PERSON -if there are questions about the submittal. Name: Matt Carlman Company Name: Mailing Address: E-mail Address: Fire Systems West 206 Frontage Rd N. Suite C MattC@firesystemswest.com City State Zip Day Telephone: 253-951-6005 NICET III number: 125166 Pacific City Fax Number: Contractor's City of Tukwila Business License number: WA, 98047 State Zip 253-735-0113 BUS -0994434 Total number of new/relocated devices or sprinkler heads: 17 Valuation of Project (contractor's bid price): $ 4500 Scope of Work (please provide detailed information): Improvement. Install New Fire Alarm Notification Devices for Tenant PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal Is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASkTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. f BUILDING OW ► ' 4.4 AUTHORIZED AGENT: MAR 12 2019 Signature: TUKWILA FIRE Date: 03/12/2019 Print Name: Matt Carlman Day Telephone: 253-951-6005 Plan Permit App.doc 8/22/14 TFD FP Form 8 fik 5007 Pacific Hwy. E. #7 • Fife, Wa. 98424 • 14 rw gat T P1 Phone (253)926-1947 • Fax (253)926-1996 Email organization ar autocomcorp.com • Website www.autocomcorp.com Battery Calculations For Roof Corp 3425 S. 146th Street Tukwila, Wa. 98167 Fire Alarm System Rev A Date OS -13-2010 System Power Requirements 7100 Series Fire Alarm Control Panel Protected Premises: Roof Corp Address: 3425 South 146th Street Date: 5/13/2010 City: Tukwila State: Wa Zip: 98168 Prepared By: Automated Communications Corp Address: 5007 Pacific Hwy E Suite 7 Email: City: Fife State: Wa Phone: 253-926-1947 Zip: 98424 Secondary Load Requirements Total Secondary Load from the calculation table below. 3.62 Amp Hours Current Draw 3.38 Amp Hours Time (hours) ( Total (AH) Secondary Standby Load 0.125 A x Required Standby Time 24 hours 3.00 Secondary Alarm Load 0.245 A x Required Alarm Time (hours) 0.084 hours 0.02 Total Secondary Load 3.02 Derating factor x 1.20 Secondary Load Requirements 3.62 AH Battery Selection Select batteries from the list below. 7.00 7.0 AH Battery (12 volt) Amp Hours Battery Distribution Chart Shows amp -hour distribution of your selections. Secondary Standby Load 52% Secondary Alarm Load 0% Spare Battery Capacity 48% O Spare Battery Capacity O Secondary Standby Load o Secondary Alarm Load Spare Battery Capacity 3.38 Amp Hours Secondary Standby Load 3.60 Amp Hours Secondary Alarm Load 0.02 Amp Hours Gammen rclmaw System Current Draw 7100 Series Fire Alarm Control Panel Device 1. System (Please only select one) Draw Standby Qty Draw Alarm sic By fe 2•St:C Basic System Module, ' LO wig DACT= 0 1 x x 0.06500 0.07500 0.07500 0 1 x x 0.08500 0.09500 0.09500 Basic Sy n Module, 2 SLC with DACT 0 x 0.08500 0 x 0.10500 Printer Transient Module (PTRM) 0, x 0.02000 0 x 0.02000 Class A Option Module (CAOM) 0 x 0.00100 0 x 0.00100 Municipal Circuit Option Module (MCOM) 0 x 0.00100 0 x 0.00100 Optional Remote Serial Annunicator (LCD -7100) 1 x 0.05000 0.05000 1 x 0.07500 0.07500 Remote LED Driver Module (LDM-7100) 0 x 0.03500 0 x 0.20000 Intelligent Network Interface Module - Copper Wire (INI-7100-UTP) 0 x 0.04000 0 x 0.04000 Intelligent Network Interface Module - Fiber Optic (INI-7100-FO) 0 x 0.04000 0 x 0.04000 2. Two -Wire Smoke Detectors Two -wire Smoke Detector 1 x 0:00000 0 x 0:00000 Two -wire Smoke Detector 2 0 x 0.00000 0 x 0.00000 Two -wire Smoke Detector 3 0 x 0.00000 0 x 0.00000 Two -wire Smoke Detector 4 0 x 0.00000 0 x 0.00000 3. Four -Wire Smoke Detectors Four -wire Smoke Detector 1 0 x 0.00000 0 x 0.00000 Four -wire Smoke Detector 2 0 x 0.00000 0 x 0.00000 Four -wire Smoke Detector 3 0 x 0.00000 0 x 0.00000 Four -wire Smoke Detector 4 0 x 0.00000 _ 0 x 0.00000 4. Notification Appliances NAC TRIGGER 1 x 0.00000 0.00000 1 x 0.07500 0.07500 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 x 0.00000 0 x 0.00000 Total Standby To oa 0.125 A 'oto alarm oad: 0.245 A Potter PSN -106 uit Namo urrent Draw �ndby `Alarm tms Per. .Leng 300 F One - Circuit 1-B1 Circuit 1-B2 Circuit 1-B3 Circuit 1-B4 Aux Power Out otal standby( 0.000 0.000 0.000 0.000 0:000 5; 075 0.798 1.356 1.200 0.000 0.000 .5 7 #14 Solid #14 Solid #14 Solid #14 Solid #14 Solid 3.354 totalAlain Cu 2.52 400 400 400 400 400 2.02 (Mips) Total ©utputPower,Require ps). endby rtit Standbu) in 4 0.083 702 Time Min 0 (5 Mins) Tait' A ctuir?ed Total Combined AH Required Mtl 1ply By„AThe l erating:Fgt 2 or Minimum Battery"AmpHour 2.3f 2 6.70% 11.39%0.: 10.08% 0.00%: 0.00% Wire resistances are based upon an ambient temperature of 72 degrees F. Because of the minimal difference between solid and stranded wire no differential was made. 5499(2) Circuit 2-7 5499(2) Circuit 2-8 5499(2) Circuit 2-9 5499(2) Circuit 2-10 5499(2) Aux Power Out urrent Draw dbti :Alarm 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Wire AWG Ohms Per Lente & 1000 Ft , Onetu #14 Solid #14 Solid #14 Solid #14 Solid #14 Solid 5499 -Rowe 0.075 75 0.000 2.52 :2.52 5; 2.52 300 300 300 300 22 2,52;: (Mips) Total OtttputPower Requi 500 2400 0.00%' 0.00% 0.00% 0.00% 000% 75' .175 Total A( standby Time in Hours Standby AH Required 4 0 Alarm e in Klin s 0 A015 Total Alarm-AH'Requir lultiply Ely The 1.10 tery J;mpH( u 2.00 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of the minimal difference between solid and stranded wire no differential was made. Project Information Project Name: Roof Corp Prepared By: Brad Young Project ID: 0 Date: 5/13/2010 ID: Potier PSN - CU Currer t: 3 System Sensor P2R Wall Horn/Strobe 75 urrent C andby aw Each Current Draw Total Alarm Standby. Alarm 0.123 0.000 69, 2 System Sensor SR Wall Strobe 75 O 0 0153 0.000 0.306 1 System Senser P2RK WP Horn/storbe 75 0.! .0.123 0.000 0.;123 System Sensor SRK Wall Strobe 75 '0 0.176 0.000 0.000 0.000 0.000 Totals 0.000 0.798 anel ID: Potter PSN -106 fax Circuit Current: 3 Amps 3 System Sensor P2R Wall Horn/Strobe 75 urrent Draw Each Current Draw Total ndby Alarm Standby Alarm 0.000 0.123 0.000 0.369 3 System Sensor SR Wall Strobe 75 Oi 53 :>>. 0.000 0.459 3 System Sensor PC2R Ceiling Hom/Strobe 75 0.000 176 0.000 0.528 0 Unused 0.000 0.000 0.000 0.000 0.000=, 0.000 Totals 0.000 1.356 2 System Sensor PC2R Ceiling Horn/Strobe 75 Panel ID: Potter PSN -106 Mai Circuit Current: „,3 Amps Current Draw Each Current DrawTotal Standby Alarm Standby Alarm 0j l76 0.000 0.352 4 System Sensor PC2R Ceiling Horn/Strobe 110 0 0.212 0.000 0 Unused 0.000 0.000 0.000 0.000 0 Unused 1.000 0.000 0.000 0.000 Totals 0.000 1.200 el ID: Potter PSN -106 ix Circuit Current: 3 Amps Current Draw Each Current Draw Total Standby Alarm Standby Alarm 0 Unused w0 0.000 0.000 0.000 0 Unused 0 0.000 0.000 0000 0 Unused ►0 0.000 0.000 X00 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 5007 Pacific Hwy. E. #7 • Fife, Wa. 98424 • Phone (253)926-1947 • Fax (253)926-1996 Email organizationAautocomcorp.com • Website www.autocomcorp.com Voltage Drop Calculations For Roof Corp 3425 S. 146th Street Tukwila, Wa. 98167 Fire Alarm System Rev A Date 05-13-2010 5499 Power Expander Calculations Circuit 1-B1 Circuit 1-B2 Circuit 1-B3 Circuit 1-B4 Aux Power Out 0499 P wer 0.000 0.000 0.000 0.000 0.798:: 1.356 1200 0-000; 0x)00 X0176 .083 #14 Solid 5 400 10. #14 Solid #14 Solid #14 Solid 400 400 400 10.08%` 0 n Wire resistances are based upon an ambient temperature of 72 degrees F. Because of the minimal difference between solid and stranded wire no differential was made. 5499(2) Circuit 2-7 5499(2) Circuit L-8 5499(2) Circuit 2-9 5499(2) Circuit 2-10 5499(2) Aux Power Out 5499Ptrs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 .0;000 0 7 #14 Solid #14 Solid #14 Solid #14 Solid 300 300 300 300 Total ::0.05<; T�otat Al Wire resistances are based upon an ambient temperature of 72 degrees F. Because of the minimal difference between solid and stranded wire no differential was made. Project Information Project Name: Roof Corp Prepared By: Brad Young Project ID: 0 Date: 5/13/2010 Putter PPSN-1„06 rrent: 3 Amps Draw Each 4' Current Draw Total Alamo , Standby Alarm 3 System Sensor P2R Wall Hom/Strobe 75 0.123 0.000 0.3 2 System Sensor SR Wall Strobe 75 0000 0.306 1 System Senser P2RK WP Hom/storbe 75 0.123 0.000 0.123 System Sensor SRK Wall Strobe 75 0.176 0.000 01100' 0.000 04000 _. Totals 0.000 0.798 3 System Sensor P2R Wall Hom/Strobe 75 0.12; Current DrawTotal" Standby . ,, Alarm .z 0.000 Oaf 3 System Sensor SR Wall Strobe 75 0. 0459 3 System Sensor PC2R Ceiling Horn/Strobe 75 0.176: 0.0!:1 0,528 0 Unused 000` 0.000 0.000 00 0.00 0,000 Totals 0.000 1.356 N-1{ Amps. 2 System Sensor PC2R Ceiling Horn/Strobe 75 0.176 Current Draw Total 'Standby ,f 0,352 4 System Sensor PC2R Ceiling Hom/Strobe 110 0212` 0.000 0 Unused 0.000 0.000 0 Unused 0.000 0.000 000 0.000 Totals 0.000 1.200 0 Unused 0.000 Current Draw Total Standby Alarm 0.000 0.000 0 Unused o1 0.000 0.000 0.000 0 Unused 000' °0.000 0.000 Unused 0 00,, 0.000 0.000, 0.00} 0. Totals 0.000 0.000 Symbol Legend SYMBOL DESCRIPTION MANUFACTURER PART NUMBER MODEL QUANTITY USER TEXT UL FM NAC POWER SUPPLY 10 AMP 6 OUTPUT . POTTER ELECTRIC SIGNAL PSN -106 PSN -106 2 EX 7100-1D MB 1 INAC I E% Ex FACP, ANALOG ADDRESSABLE, 197 PONTS, WIDIALER GAMEWELL FCI 7100-1D 7100-1D 2 EX S1869 3003549 IFACP I $O SMOKE, PHOTO, ADDRESSABLE GAMEWELL FCI ASD-PL2F ASD-PL2F 27 S:4 S1913 3023594 ® SMOKE, PHOTO, ADDRESSABLE GAMEWELL FCI ASD-PL2F ASD-PL2F 8 ABV S1913 3023594 O THERMAL SENSOR, ANALOG, 135' F GAMEWELL FCI ATD-L2F ATD-L2F 4 0.3000mA S2332 3023594 P) PULL STATION, DOUBLE ACTION, ADDRESSABLE GAMEWELL FCI MS-7AF MS-7AF 1 Total Periph Alarm S2465 ASD-PL2F ISI L -SERIES STROBE, RED, WALL SYSTEM SENSOR SRL SRL. 4 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 5-0 4 L -SERIES 2 -WIRE, HORN STROBE, RED, WALL SYSTEM SENSOR P2RL P2RL 2 5-0 0.3000mA 20.3888V O;, L -SERIES 2 -WIRE, HORN STROBE, RED, WALL SYSTEM SENSOR P2RL P2RL 2 20.3881V (0.0007V) M:1 a L -SERIES 2 -WIRE, HORN STROBE, RED, CEILING SYSTEM SENSOR PC2RL PC2RL 1 S:13 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE /o\ STROBE, 2 WIRE, M -C, RED, CEILING SYSTEM SENSOR SCRK SCRK 2 SMOKE, PHOTO, ADDRESSABLE 53593 3023572 m EOL 5.1K Q EOL 5.1K POTTER ELECTRIC SIGNAL EOL -5.1 EOL -5.1 1 0.3000mA 20.385V (0.0007V) Battery Calculations for Panel: P1: EX Part No:7100-1 D - FACP, ANALOG ADDRESSABLE, 197 PONTS, W/DIALER Job number: 817-0576 Job name: FRESH & GREEN Address 1: 3425 S 146TH ST Address 2: TUKWILA, WA 98168 Phone: 253-833-1248 Fax: Designing engineer: MATT CARLMAN Authority having jurisdiction: CITY OF TUKWILA Part No. Qty. Description Standby Total Standby Alarm Total Alarm 7100-10 Panel Panel Equipment PSN -106 MB _ 20.4V 10 AMP 6 NAC PWR SUPPLY MB S:1 7100-1D MB 1 MAIN MOTHER BAORD W/DACT, 197 75.0000mA 75.0000mA 95.0000mA 95.0000mA ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 4'-0 Total Panel Stby 75.0000mA Total Panel Alarm 95.0000mA ASD-PL2F SMOKE, PHOTO, ADDRESSABLE Peripheral Devices 0.3000mA 20.3969V (0.0009V) S:4 ASD-PL2F 35 SMOKE, PHOTO, ADDRESSABLE (Signaling line) 0.3000mA 10.5000mA 6.5000mA 227.5000mA ATD-L2F 4 THERMAL SENSOR, ANALOG, 135 F (Signaling line) 0.3000mA 1.2000mA 6.5000mA 26.0000mA MS-7AF 1 PULL STATION, DOUBLE ACTION, ADDRESSABLE (Signaling line) 0.3000mA 0.3000mA 10.0000mA 10.0000mA ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 12'-0 Total Peripheral Stby 12.0000mA Total Periph Alarm 263.5000mA ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 7'-0 0.3000mA 20.3902V (0.001V) S:10 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 5-0 Total Standby Amps 87.0000mA Total Alarm Amps 358.5000mA Standby time: 24 Hrs 2.088Ah Alarm time: 5 Min 0.03Ah Battery requirement: 2.118Ah Compensation Factors - Standby: 1.2 Alarm: 1.2 Requirement with compensation: 2.541Ah 14/2 PSN -106 FCI 7100 20 AMP 16/2 Circuit Calculations Panel: P1 Card: 00 Circuit:SLC1 - Device Circuit Type: _ Part No Circuit Name: SLC1 Signaling Zine/FCI - SLC, Velociti, CLIP Terminal Cable: 18/2 SOL JKT FPLR 1M RL Calculations based on RunningLength. unpin Total _ Desitin Criteria: Ambient temperature_ 167°F Max. Appliance Desc Voltage: 20.4V:DC RED #18 operating voltag_e Distance Amperage: drop_ 10% Current 1.0000A ____________ Voltage ________ Voltage Drop Total Alarm 7100-10 Panel Panel Equipment PSN -106 MB _ 20.4V 10 AMP 6 NAC PWR SUPPLY MB S:1 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 5-0 0.3000mA 20.3985V (0.0015V) 5:2 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 4'-0 0.3000mA 20.3978V (0.0007V) S:3 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 6-0 0.3000mA 20.3969V (0.0009V) S:4 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 3'-0 0.3000mA 20.3964V (0.0005V) S:5 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 12'-0 0.3000mA 20.3944V (0.002V) S:7 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 8'-0 0.3000mA 20.3931V (0.0013V) S:8 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 12'-0 0.3000mA 20.3912V (0.0018V) S:9 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 7'-0 0.3000mA 20.3902V (0.001V) S:10 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 5-0 0.3000mA 20.3895V (0.0007V) S:11 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 5-0 0.3000mA 20.3888V (0.0007V) S:12 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 5'-0 0.3000mA 20.3881V (0.0007V) M:1 MS-7AF PULL STATION, DOUBLE ACTION, ADDRESSABLE 5'-0 0.3000mA 20.3875V (0.0007V) S:13 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 7'-0 0.3000mA 20.3866V (0.0009V) S:14 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 7'-0 0.3000mA 20.3857V (0.0008V) S:15 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 6'-0 0.3000mA 20.385V (0.0007V) S:16 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 5-0 0.3000mA 20.3844V (0.0007V) S:17 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 5-0 0.3000mA 20.3837V (0.0006V) S:18 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 20'-0 0.3000mA 20.3817V (0.0021V) S:19 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 7'-O 0.3000mA 20.381V (0.0007V) S:20 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 9'-0 0.3000mA 20.3801V (0.0008V) S:21 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 5-0 0.3000mA 20.3796V (0.0005V) S:22 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 5-0 0.3000mA 20.3791V (0.0005V) S:23 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 6'-0 0.3000mA 20.3786V (0.0005V) S:24 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 7'-0 0.3000mA 20.3785V (0.0002V) S:26 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 7'-0 0.3000mA 20.3783V (0.0001V) S:28 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 5'-0 5'-0 0.3000mA 0.3000mA 20.3783V 20.3782V (0.0001V) (OV) S:30 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE S:32 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 5'-0 0.3000mA 20.3782V (OV) S:25 ATD-L2F THERMAL SENSOR, ANALOG, 135' F 6'-0 0.3000mA 20.3783V (0.0003V) S:27 ATD-L2F THERMAL SENSOR, ANALOG, 135' F 9'-0 0.3000mA 20.3779V (0.0004V) S:29 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 5'-0 0.3000mA 20.3777V (0.0002V) S:31 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 4'-0 0.3000mA 20.3775V (0.0001V) S:34 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 5-0 0.3000mA 20.3774V (0.0001V) S:36 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 6'-0 0.3000mA 20.3773V (0.0001V) S:37 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 6'-0 0.3000mA 20.3772V (0.0001V) S:38 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 5-0 0.3000mA 20.3772V (OV) S:39 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 4'-0 0.3000mA 20.3772V (0V) S:33 ATD-L2F THERMAL SENSOR, ANALOG, 135' F 8'-0 0.3000mA 20.3775V (0.0001V) S:35 ATD-L2F THERMAL SENSOR, ANALOG, 135' F 6'-0 0.3000mA 20.3774V (OV) S:6 ASD-PL2F SMOKE, PHOTO, ADDRESSABLE 3'-0 0.3000mA 20.3943V (OV) 261'-0 12.0000mA Total Current: 12.0000mA (Total VDrop Percent:0.11 %) Total Voltage Drop : 0.0228V 16/2 �0 ® 0 © © 0 0 0 0 0 0 0 20 AIBP DEDICATED CIRCUIT WIRING DIAGRAM P Battery Calculations for Panel: P4: EX Part No:PSN-106 - NAC POWER SUPPLY 10 AMP 6 OUTPUT Part No. Qty. Description Standby Total Standby Alarm . Total Alarm FAX: PSN -106 Panel Equipment PSN -106 MB _ . 1 10 AMP 6 NAC PWR SUPPLY MB 60.0000mA 60.0000mA 200.0000mA 200.0000mA 13'-0 69.0000mA 20.3247V Total Panel Stby 60.0000mA Total Panel Alarm 200.0000mA 8'-0 158.0000mA Peripheral Devices (0.0429V) 2 P2RL L -SERIES 2 -WIRE, HORN STROBE, RED, WALL, 95CD SRL 4 L -SERIES STROBE, RED, WALL (Notification) 0.0000mA 0.0000mA 43.0000mA 172.0000mA P2RL 2 L -SERIES 2 -WIRE, HORN STROBE, RED, WALL (Notification) 0.0000mA 0.0000mA 53.0000mA 106.0000mA P2RL 2 L -SERIES 2 -WIRE, HORN STROBE, RED, WALL (Notification) 0.0000mA 0.0000mA 140.0000mA 280.0000mA PC2RL 1 L -SERIES 2 -WIRE, HORN STROBE, RED, CEILING (Notification) 0.0000mA 0.0000mA 69.0000mA 69.0000mA SCRK 2 STROBE, 2 WIRE, M -C, RED, CEILING (Notification) 0.0000mA 0.0000mA 158.0000mA 316.0000mA 14'-O 43.0000mA 20.075V Total Peripheral Stby 0.0000mA Total Periph Alarm 943.0000mA 9'-0 43.0000mA 20.0561V (0.0188V) SYSTEM SENSOR SCRK STROBE, 2 WIRE, M -C, RED, CEILING, 75CD 14'-0 158.0000mA 20.0305V Total Standby Amps_ 60.0000mA Total Alarm Amps 1143.0000mA Standby time: 24 Hrs 1.44Ah Alarm time: 5 Min 0.095Ah Battery requirement: 1.535Ah Compensation Factors - Standby: 1.2 Alarm: 1.2 Requirement with compensation: • 1.842Ah Circuit Calculations Panel: P4 Card: 03 Circuit:SIG4 Circuit Name: 8104 Circuit Type: Notification Terminal Voltage: 20.4V:DC Cable: 14/2 SOL JKT FPLR 1M RL RED Calculations based on Running Total Design Criteria: Ambient temperature: 167°F Max. operating Amperage: #14 Length. volta Distance 3.0000A e drop: 10% Current Voltage Voltage Drop Device Part No Appliance Desc FAX: PSN -106 Panel WA ST LICENSE: FIRESWI055LW 20.4V 1 PC2RL L -SERIES 2 -WIRE, HORN STROBE, RED, CEILING, 15CD 13'-0 69.0000mA 20.3247V (0.0753V) SCRK STROBE, 2 WIRE, M -C, RED, CEILING, 75CD 8'-0 158.0000mA 20.2818V (0.0429V) 2 P2RL L -SERIES 2 -WIRE, HORN STROBE, RED, WALL, 95CD 5-0 140.0000mA 20.2466V (0.0352V) 3 P2RL L -SERIES 2 -WIRE, HORN STROBE, RED, WALL, 15CD 23'-0 53.0000mA 20.1653V (0.0813V) 4 SRL L -SERIES STROBE, RED, WALL, 15CD 8'-0 43.0000mA 20.1396V (0.0257V) 5 SRL L -SERIES STROBE, RED, WALL, 15CD 5-0 43.0000mA 20.116V (0.0236V) 6 P2RL L -SERIES 2 -WIRE, HORN STROBE, RED, WALL, 15CD 3'-0 53.0000mA 20.108V (0.008V) 7 SRL L -SERIES STROBE, RED, WALL, 15CD 14'-O 43.0000mA 20.075V (0.033V) 8 SRL L -SERIES STROBE, RED, WALL 15CD 9'-0 43.0000mA 20.0561V (0.0188V) SYSTEM SENSOR SCRK STROBE, 2 WIRE, M -C, RED, CEILING, 75CD 14'-0 158.0000mA 20.0305V (0.0256V) 9 P2RL L -SERIES 2 -WIRE, HORN STROBE, RED, WALL, 95CD 7'-0 140.0000mA 20.0245V (0.006V) SYM 115'-0 943.0000mA Total Current: 943.0000mA (Total VDrop Percent:1.84%) Total Voltage Drop : 0.3755V 16/2 0 16/2 116/2 ( 0 (0 ® o:© 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ® Without Comments As Noted in Red O Per The Attached Letter hese plans have been reviewed by the Tukwila Fire ,vention Bureau for conformance with current City 'mndards. Acceptance is subject to errors and ,-fissions which do not authorize violations of 3ndards and ordinance: The responsibility for the 'equacy of design1`e. t:.y totally with dIe designer. Iditions, deletion's (0 evisions to mese drawings after lis date will void this ac ceptarice and will require a esubmittai of drawings for subsequent approval. Final acceptance sa_io)ecTi to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: '3 �- t G By: l aF Zns , i t e OL y ..o yrc k h L ote'641,6-. j tr, want --0-. W a t-tr., 1...e.ei4,. l 1? no} regtoti 014 ti+a;ti tii-6,,At-e ) 1 C 4 ak►wwc.rw -• LL►s�K. h > 44%.J►k ti4�w o>^ 04a;c4LJ FA/Ps c;cwA- t,►tv tl�,.. r1 k =.. I.J PAF: p@°�i�I :!° Piens call4,.U,-5-5✓75_4',a1' 7•ind give this Fire ' €"errii $ k. No. 101 - r- 045- and sisand exact doi'ess for shut- down or restoration approv li. A GENERAL NOTES ! SCOPE OF WORK 1. SYSTEM WIRING NOTED ON THE DRAWINGS IS PER MANUFACTURE AND CODE REQUIREMENTS. ANY ALTERATION TO SYSTEM WIRING, WITHOUT APPROVAL, IS AT ELECTRICAL CONTRACTOR'S OWN RISK!! 2. SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATIC AND ONLY USED FOR REFERENCE PURPOSES. ACTUAL WIRE AND DEVICE INSULATION MAY VARY DUE TO OBSTRUCTIONS. 3. WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING TO FIRE PROTECTION EQUIPMENT. OTHER WIRE SHALL NOT BE PERMITTED IN THE SAME RACEWAY. 4. FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST U.L., N.E.C., N.F.P.A., W.A.C., AND OTHER STANDARDS AS APPLICABLE TO THE CITY STANDARDS. 5. WHEN NECESSARY, DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY AVAILABILITY, ETC. FIRE SYSTEMS WEST RESERVES THE RIGHT TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED, WITH EQUIPMENT OF EQUAL OR BETTER QUALITY, FUNCTION AND DESIGN. 6. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ALL NOTIFICATION APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. 7. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ANALOG INITIATING DEVICE CIRCUITS IS PERMISSIBLE. 8. THIS SPACE IS NOT EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM. 9. FIRE SYSTEMS WEST WILL BE RELOCATING EXISTING FIRE ALARM PANEL. 10. FIRE SYSTEMS WEST WILL RELOCATING EXISTING FIRE ALARM INITIATING DEVICES FOR TENANT IMPROVEMENT. 11. FIRE SYSTEMS WEST WILL BE RELOCATING EXISTING FIRE ALARM NOTIFICATION DEVICES FOR TENANT IMPROVEMENT. FIRE ALARM SYSTEM INFORMATION INSTALLER!SUPPLIER SITE CONTACT: FRESH & GREEN DESIGN/SUPPLIER: FIRE SYSTEMS WEST, INC. 3425 S 146TH ST 206 FRONTAGE ROAD NORTH, STE TUKWILA, WA 98168 PACIFIC, WASHINGTON 98047 PHONE: PHONE: (253) 833-1248 FAX: FAX: (253)735.0113 WA ST LICENSE: FIRESWI140B1 WA ST LICENSE: FIRESWI055LW DESIGNER MATT CARLMAN FIRE SYSTEMS WEST, INC 206 FRONTAGE ROAD NORTH, STE C PACIFIC, WASHINGTON 98047 PHONE: (253) 833-1248 FAX: (253) 735-0113 X NICET LEVEL 11 146053 A 1412 FPLP B 1612FPLP EX EXISTING LOCATION (SWAP FOR NEW DEVICE) WP WEATHER PROOF N NEW DEVICE R RELOCATE • STROBE COVERAGE AREA SHALL BE DEFINED AS: 10 FT. CLG. HT. 20 FT. CLG. HT. 30 FT. CLG. HT. 15 cd = 20'x20' 30 cd = 205(20' 75 cd = 20)(20' 30 cd = 305(30' 75 ed = 30130' 95 cd = 305(30' 75 cd = 40'x40' 95 cd = 40X40' 110 cd =40X40' 95cd=50550' 110cd=50X50' 115cd=505150' Drawing reviewed by: Rodrigo G. Quinteros NICET Certification No. 125166 Fire Alarm Systems - Level III Certification Expires: October 1, 2019 DVOXpre.;s Kiosk @ is Super Saver Foods Cosh Amcric S 146t11 Si ttybuft Esp. VICINITY MAP SCALE: N.T.S. P I4 AR 12 2019 TUKWILA FIRE cc sikr- 64) 6 FRONTAGE RO CV z 0 z a 3 1 u 0 u LI 3 w 0 BY IWC DATE o) o. to 0 a 5 ISSUED_FOR_REVIEW Z T. NEW DEVICE COUNT QUANITY, 0 0 0 0 0 0 1 M WHITE ►W- WHITE tW--- 0 WHITE WHITE MODEL MZ3d P2RK N O. CO CO W Ili 4. ti N a ASD-PL2F ATD-L2F LL. SYSTEM SENSOR E SYSTEM SENSOR SYSTEM SENSOR SYSTEM SENSOR GAMEWELL FCI GAMEWELL FCI GAMEWELL FCI TYPE CEILING HORN STROBE OUTDOOR WALL HORN STROB WALL HORN STROBE WALL STROBE ce oco 1= uJ „atW N) cnY a N HEAT SENSORS uuu unnain SYM Z a ct w ce LL FRESH & GREEN z 00 w `� LU co ce 08) LLI 14, z no CV C0.7 LL.M H ON-SITE CONTACT: ABDI ADAN CO LL7 C? ti or - CO 0) 00/1 ICA C3 9 11 igk IL. cn 1- w W t"n 2'4' 6' GALE: 114"=1'-0" 12' 20' GENERAL NOTES ! SCOPE OF WORK 1. SYSTEM WIRING NOTED ON THE DRAWINGS IS PER MANUFACTURE AND CODE REQUIREMENTS. ANY ALTERATION TO SYSTEM WIRING, WITHOUT APPROVAL, IS AT ELECTRICAL CONTRACTOR'S OWN RISKI! 2. SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATIC AND ONLY USED FOR REFERENCE PURPOSES. ACTUAL WIRE AND DEVICE INSULATION MAY VARY DUE TO OBSTRUCTIONS. 3. WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING TO FIRE PROTECTION EQUIPMENT. OTHER WIRE SHALL NOT BE PERMITTED IN THE SAME RACEWAY. 4. FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST U.L., N.E.C., N.F.P.A., W.A.C., AND OTHER STANDARDS AS APPLICABLE TO THE CITY STANDARDS. 5. WHEN NECESSARY, DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY AVAILABILITY, ETC. FIRE SYSTEMS WEST RESERVES THE RIGHT TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED, WITH EQUIPMENT OF EQUAL OR BETTER QUALITY, FUNCTION AND DESIGN. 6. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ALL NOTIFICATION APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. 7. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ANALOG INITIATING DEVICE CIRCUITS IS PERMISSIBLE. 8. THIS SPACE IS NOT EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM. 9. FIRE SYSTEMS WEST WILL BE RELOCATING EXISTING FIRE ALARM PANEL. 10. FIRE SYSTEMS WEST WILL RELOCATING EXISTING FIRE ALARM INITIATING DEVICES FOR TENANT IMPROVEMENT. 11. FIRE SYSTEMS WEST WILL BE RELOCATING EXISTING FIRE ALARM NOTIFICATION DEVICES FOR TENANT IMPROVEMENT. FIRE ALARM SYSTEM INFORMATION INSTALLERISUPPLIER SITE CONTACT: FRESH & GREEN DESIGNISUPPLIER: FIRE SYSTEMS WEST, INC. 3425 S 146TH ST 206 FRONTAGE ROAD NORTH, STE TUKWILA, WA 98168 PACIFIC, WASHINGTON 98047 PHONE: PHONE: (253) 833.1248 FAX: FAX: (253)"735.0113 WA ST LICENSE: FIRESWI140B1 WA ST LICENSE: FIRESWI055LW DESIGNER MATT CARLMAN FIRE SYSTEMS WEST, INC 206 FRONTAGE ROAD NORTH, STE C PACIFIC, WASHINGTON 98047 PHONE: (253) 833.1248 FAX: (253) 735-0113 X 7/// NICET LEVEL 11 146053 A 1412 FPLP B 1612 FPLP EX EXISTING LOCATION (SWAP FOR NEW DEVICE) WP WEATHER PROOF N NEW DEVICE R RELOCATE • STROBE COVERAGE AREA SHALL BE DEFINED AS: 10 FT. CLG. HT. 20 FT. CLG. HT. 30 FT. CLO. HT. 15cd=20520' 30cd=2020' 75cd=207,20' 30cd=30130' 75cd=30130' 95cd=30'x30' 75 ad = 407x40' 96 cd = 405(40' 110 cd = 40140' 95 cd = 50X50' 110 cd = 50X60' 115 cd =50'x50' lgrearm Rejuveriatesalan it'no`s GriI oost Mobile ,', DVDXpress Kiosk ( Vs Super Saver Foods #4btb �t 3425'Sou th`146th Street VICINITY MAP SCALE: N.T.S. Amara 0 311 w H *= cn VO ) a ri) 206 FRONTAGE RO z • N CO 0 1— to M B: co < Fax: (253) 735-0113 3 u u a uu u WA PI CIQCC hc a BY MWC DATE P. 8 coz 0 us 1 1 ISSUED_FOR_REVIEW ci ci r NEW DEVICE COUNT 0 0 0 0 0 0 0 HSINI I WHITE WHITE WHITE WHITE RED WHITE WHITE MODEL g cif, w W al Li' co W an. c42 ATD-L2F MFG SYSTEM SENSOR E SYSTEM SENSOR SYSTEM SENSOR SYSTEM SENSOR GAMEWELL FCI GAMEWELL FCI GAMEWELL FCI TYPE CEIUNG HORN STROBE OUTDOOR WALL HORN STROB WALL HORN STROBE WALL STROBE PULL STATION SMOKE SENSORS HEAT SENSORS . SYM a z c 1- 0 z 0 w H z 0 1) 0 11 0 0 w 0. itt 1 w w 0 3 FILE:Fresh & Green Fire Alarm Plans.cad DATE:03/11/19TIME:16:28:43 FREEZER FRESH & GREEN — 1111111 Idis: $1 12' 1/4'=1-0" 20' NOTIFICATION FIRE ALARM PLAN GENERAL NOTES ! SCOPE OF WORK 1. SYSTEM WIRING NOTED ON THE DRAWINGS IS PER MANUFACTURE AND CODE REQUIREMENTS. ANY ALTERATION TO SYSTEM WIRING, WITHOUT APPROVAL, IS AT ELECTRICAL CONTRACTOR'S OWN RISK!! 2. SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATIC AND ONLY USED FOR REFERENCE PURPOSES. ACTUAL WIRE AND DEVICE INSULATION MAY VARY DUE TO OBSTRUCTIONS. 3. WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING TO FIRE PROTECTION EQUIPMENT. OTHER WIRE SHALL NOT BE PERMITTED IN THE SAME RACEWAY. 4. FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST U.L., N.E.C., N.F.P.A., W.A.C., AND OTHER STANDARDS AS APPLICABLE TO THE CITY STANDARDS. 5. WHEN NECESSARY, DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY AVAILABILITY, ETC. FIRE SYSTEMS WEST RESERVES THE RIGHT TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED, WITH EQUIPMENT OF EQUAL OR BETTER QUALITY, FUNCTION AND DESIGN. 6. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ALL NOTIFICATION APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. 7. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ANALOG INITIATING DEVICE CIRCUITS IS PERMISSIBLE. 8. THIS SPACE IS NOT EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM. 9. FIRE SYSTEMS WEST WILL BE RELOCATING EXISTING FIRE ALARM PANEL. 10. FIRE SYSTEMS WEST WILL RELOCATING EXISTING FIRE ALARM INITIATING DEVICES FOR TENANT IMPROVEMENT. 11. FIRE SYSTEMS WEST WILL BE RELOCATING EXISTING FIRE ALARM NOTIFICATION DEVICES FOR TENANT IMPROVEMENT. FIRE ALARM SYSTEM INFORMATION INSTALLERISUPPLIER SITE CONTACT: FRESH & GREEN DESIGN/SUPPLIER: FIRE SYSTEMS WEST, INC. 3425 S 146TH ST 206 FRONTAGE ROAD NORTH, STE TUKWILA, WA 98168 PACIFIC, WASHINGTON 98047 PHONE: PHONE: (253) 833-1248 FAX: FAX: (253) 735-0113 WA ST LICENSE: FIRESWI140B1 WA ST LICENSE: FIRESWI055LW DESIGNER MATT CARLMAN FIRE SYSTEMS WEST, INC 206 FRONTAGE ROAD NORTH, STE C PACIFIC, WASHINGTON 98047 PHONE: (253) 833-1248 FAX: (253) 735-0113 X NICET LEVEL II 146053 A 14/2 FPLP B 16/2 FPLP EX EXISTING LOCATION (SWAP FOR NEW DEVICE) WP WEATHERPROOF N NEW DEVICE R RELOCATE • STROBE COVERAGE AREA SHALL BE DEFINED AS: 10 FT. CLG. HT. 20 FT. CLG. HT. 30 FT. CLG. HT. 15 cd = 20'x20' 30 cd = 20x20' 75 cd = 20520' 30 cd = 30x30' 15 cd = 305(30' 95 cd = 30x30' 75 cd = 405(40' 95 cd 40x40' 110 cd =40x40' 95cd=50x50' 110cd=50x50' 116cd=50x5(7 Rejuveri to:Salon rs Super, Saver Foods DVDX )res Kiosk (d) ar's Super Saver Foods yclni VICINITY MAP SCALE: N.T.S. Fax: (253) 735-0113 D C u 00 u c. u z GL 2 W LL u_ z W W 0 w Z °O w coui ON-SITE CONTACT: ABDI ADAN (0 ti rte. co 11 kr u 1- v W 0. egc Ct 1- W LU Z cn FILE:Fresh & Green Fire Alarm Plans.cad DATE:03/11/19 TIME:14:09:05 - i BY MWC el 0 0) i te' 0 N E, LL' 1 ISSUED FOR REVIEW a 10.00 0 8 0000 tq WHITE WHITE WHITE ~ RED Iw— I-- WI 1 MODEL a a 20 0 w CO Z ASD-PL2F ATD-L2F MFG SYSTEM SENSOR E SYSTEM SENSOR SYSTEM SENSOR SYSTEM SENSOR GAMEWELL FCI GAMEWELL FCI GAMEWELL FCI }j TYPE CEILING HORN STROBE OUTDOOR WALL HORN STROB WALL HORN STROBE ' WALL STROBE PULL STATION SMOKE SENSORS HEAT SENSORS wuU I kIn 1a. •E DOG z GL 2 W LL u_ z W W 0 w Z °O w coui ON-SITE CONTACT: ABDI ADAN (0 ti rte. co 11 kr u 1- v W 0. egc Ct 1- W LU Z cn FILE:Fresh & Green Fire Alarm Plans.cad DATE:03/11/19 TIME:14:09:05 - FIRE ALARM GENERAL NOTES: 01. CAUTION; - THIS SYSTEM DESIGN IS BASED ON CONTRACT DRAWING AND AUTOMATED COMMUNICATIONS CORP. ("AUTOMATED"), SYSTEM CONFIGURATION AS OF THE DATE OF THE LATEST REVISION TO THESE DRAWINGS. AUTOMATED MUST BE CONSULTED PRIOR TO CHANGING CONTRACT DRAWING, SUCH CHANGES MAY EFFECT SYSTEM CONFIGURATION, INTENDED DESIGN OR THE SYSTEM'S PROPER -PERFORMANCE. 02. IDENTIFYING NUMBERS ADJACENT TO A DEVICE SYMBOL DENOTES ORDER OF WIRING. (ie: DEVICE NUMBER "X1-2". "X" IDENTIFIES THE CIRCUIT DESIGNATION, "1" IDENTIFIES THE CIRCUIT NUMBER, AND "-2" IDENTIFIES THE DEVICE AS THE SECOND DEVICE CONNECTED TO THE CIRCUIT. 03. THE CIRCUIT ROUTING AND WIRING COUNTS (IF SHOWN) ON THE FLOOR PLAN DRAWINGS ARE SHOWN DIAGRAMMATIC BASED ON CONTINUOUS AND SHORTEST POSSIBLE ROUTING FROM THE CONTROL PANEL AND BETWEEN CONNECTED FIELD DEVICES WITH NO PHYSICAL OBSTRUCTIONS. THE WIRE OR CIRCUIT COUNTS (IF SHOWN) ARE PROVIDED AS A CONVENIENCE ONLY AND AS A MEANS TO HASTEN INSTALLATION OR TO DETERMINE CONDUIT FILL. HOWEVER, WIRE OR CIRCUIT COUNTS ARE NOT GUARANTEED TO BE FREE OF ERRORS. INSTALLER MUST BE THOROUGHLY FAMILIARIZED WITH EACH DIFFERENT TYPE OF CIRCUIT AND ITS CIRCUIT SUPERVISORY REQUIREMENTS. REFER TO FIELD WIRING DIAGRAM AND DEVICE MANUALS FOR CORRECT CIRCUIT REQUIREMENTS IN CONJUNCTION WITH REQUIRED CIRCUIT ROUTING. FOR TECHNICAL QUESTIONS, CALL AUTOMATED'S PROJECT ENGINEER AT PHONE 1-(253)-926-1947, 04. "AS -BUILT" DRAWING ARE REQUIRED FOR THIS PROJECT. SUBMIT "AS -BUILT" DRAWINGS OF CONDUIT ROUTING AS WELL AS CIRCUIT ROUTING TO AUTOMATED AS SOON AS POSSIBLE. THIS INFORMATION IS REQUIRED TO BE PART OF THE "OWNER'S OPERATION MANUALS", FAILURE TO SUBMIT "AS -BUILT" INFORMATION WILL CAUSE DELAY IN PROJECT CLOSEOUT. 05. FACTORY RECOMMENDED MINIMUM WIRE SIZES, TYPE AND CONSTRUCTION AS NOTED ON THE FOLLOWING CHARTS (LEGEND: CIRCUIT DESIGNATION) MUST BE STRICTLY FOLLOWED. ANYONE WISHING TO MAKE CHANGES WILL DO SO AT THEIR OWN RISK !!! 06. ALL WIRING AND INSTALLATION SHALL CONFORM WITH THE LATEST U.L., N.E.C., N.F.P.A., W.A.C., AND OTHER STANDARDS AS APPLICABLE. 07. CIRCUITS OTHER THAN THOSE SHOWN ON THESE DRAWINGS SHALL NOT OCCUPY THE SAME CONDUIT RACEWAYS. (FOR CIRCUITS INSTALLED IN CONDUITS ONLY) 08, RELAY CONTACTS ARE SHOWN IN NORMAL (NON -ALARM) POSITION WITH POWER APPLIED TO THE CONTROL PANEL AND THE PANEL IN NORMAL SUPERVISORY MODE. 09. THESE DRAWINGS, ALONG WITH MANUFACTURE'S DATA SHEETS ARE PREPARED AND SUBMITTED BY AUTOMATED'S ENGINEERING DEPARTMENT AND ARE BASED ON ITS' INTERPRETATION OF THE SPECIFIED FUNCTIONAL DESIGN CRITERIA THOSE ITEMS THAT ARE NECESSARY TO BE SHOWN IN AUTOMATED DRAWINGS AND MANUFACTURER'S DATA SHEETS, BUT ARE SPECIFIED TO BE "PROVIDED BY OTHERS" IN OTHER SPECIFICATION SECTIONS, ARE INTENDED TO BE "PROVIDED BY OTHERS". 10. WHEN NECESSARY, DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY AVAILABILITY, ETC. AUTOMATED RESERVES .THE RIGHT TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED, WITH EQUIPMENT OF EQUAL OR BETTER QUALITY, FUNCTION AND DESIGN, 11, INSTALLING ELECTRICIAN SHALL IDENTIFY AND LABEL AND TAGGED ALL CIRCUITS, CABLES AND CONDUCTORS AT THE CONTROL PANEL, DATA GATHERING PANEL, TIEBOX LOCATIONS AND AT REMOTE TERMINAL JUNCTION BOXES. HENCE, ALLOW AT LEAST ONE WEEK LEAD TIME PRIOR TO AUTOMATED'S VISIT FOR FINAL CONTROL PANEL HOOKUP AND CIRCUIT TESTS FREE OF ALL OPENS, SHORTS, AND GROUNDS. FAILURE TO DO SO WILL RESULT IN BACK CHARGES TO CUSTOMER FOR UNNECESSARY VISIT AND DELAY PROJECT FINAL TEST WITH THE AHJ. ELECTRICAL CONTRACTOR SHALL FAMILIARIZE AUTOMATED TECHNICIAN WITH ALL NECESSARY INFORMATION PERTINENT TO THE INSTALLATION INCLUDING IDENTIFICATION OF CIRCUITS, CONDUITS AND WIRING, OR ANY DEVIATION REFLECTING CHANGES FROM THESE DRAWING. 12. SMOKE DETECTORS HAVE BEEN POSITIONED AT MAXIMUM OF 15 -FT. FROM THE FARTHEST WALL AND SPACED 30 -FT. APART CENTER -TO -CENTER AS APPROPRIATE, WITHOUT REGARDS TO ANY OBSTRUCTIONS, OR ANY NEARBY EQUIPMENT THAT MAY HINDER THE DETECTOR'S EFFECTIVENESS (ie: AIR SUPPLY REGISTERS, LOW BEAMS, ETC.). REFER TO 2007 NFPA 72 CONCERNING PROPER PLACEMENTS OF SMOKE OR HEAT DETECTORS,OR BEAM OBSTRUCTION DETECTORS, NOTIFY AUTOMATED REGARDING ALL NECESSARY CIRCUIT CHANGES, ADDITIONAL OR DELETED DEVICES, THAT MAY BE NECESSARY TO FOLLOW THE CODE OR AHJ. 13. AUDIBLE AND VISUAL ALARM INDICATING APPLIANCES HAVE BEEN STRATEGICALLY LOCATED FOR MAXIMUM VISIBILITY TO MEET A.D.A. REQUIREMENTS AND AUDIBILITY TO MEET AHJ, REQUIREMENTS. DO NOT RELOCATE THESE DEVICES IF AT ALL POSSIBLE. IF IT BECOMES NECESSARY TO RELOCATE, PLEASE CALL AUTOMATED PROJECT ENGINEER FOR ADVICE. PHONE: 1-(253)-926-1947. 14. IN AN EFFORT TO REDUCE NUISANCE ALARMS AND MAINTAIN SMOKE DETECTOR SENSITIVITY, THE FIRE MARSHALS OFFICE IS GOING TO BE ENFORCING CHAPTER 2 INITIATING DEVICES, SECTION 2-3,6.1.3 OF THE 2007 NFPA 72. THIS SECTION REQUIRES SMOKE DETECTOR INSTALLATION AFTER THE CONSTRUCTION CLEAN UP OF ALL TRADES IS COMPLETE AND FINAL, IT SHOULD BE NOTED THAT THIS REQUIREMENT APPLIES TO SMOKE DETECTOR INSTALLATION ONLY AND NOT OTHER TYPES OF DEVICES. THIS REQUIREMENT APPLIES TO THE SMOKE DETECTOR HEAD ONLY. THE WIRING AND SMOKE DETECTOR BASE MAY BE INSTALLED PRIOR TO CLEAN UP. AS A REMINDER, DO NOT CALL FOR YOUR FINAL INSPECTION UNTIL THE ENTIRE FIRE ALARM SYSTEM IS OPERATIONAL AND HAS BEEN PRE -TESTED IN ACCORDANCE WITH CHAPTER 7, INSPECTION, TESTING, AND MAINTENANCE, OF THE 2007 NFPA 72. THE RECORD OF COMPLETION IN ACCORDANCE WITH CHAPTER 1, FUNDAMENTALS OF FIE ALARM SYSTEMS, SECTION 1-6.2.1 OF THE 2007 NFPA 72, SHALL BE AVAILABLE TO THE INSPECTOR ON FINAL FIRE ALARM SYSTEM INSPECTION. 15. ELECTRICAL CONTRACTOR TO PROVIDE A GUTTER ABOVE TWO OR MORE FIRE ALARM PANELS. "WARNING !!!" DO NOT USE BOTTOM KNOCKOUTS USE UPPER SIDES & TOP ONLY!!! OF THE FIRE ALARM AND BOOSTER PANELS, (THE BOTTOM OF THE PANELS ARE RESERVED FOR BACKUP BATTERIES PLACEMENT). LEGEND: (CIRCUIT DESIGNATIONS/DESCRIPTIONS) DESIG: CIRCUIT REQUIREMENTS: CIRCUIT DESCRIPTIONS: PROVIDED BY: REFERENCE: A 2-#16 AWG, SOUD SINGLE CONDUCTORS ANALOG SIGNAUNG UNE CKT, ELECTRICAL B 2-#14 AWG, SOUD SINGLE CONDUCTORS AUDIBLE/VISUAL ALARM CKT. ELECTRICAL C 2C-#16 AWG. SOLID/SHIELDED CABLE AUDIO (SPEAKER) ALARM CKT, N/A D 2-#16 AWG, SOUD SINGLE CONDUCTORS DETECTION CKT, ELECTRICAL E 2-#14 AWG, SOUD SINGLE CONDUCTORS ELEVATOR RECALL CKT. N/A 4C-#16 AWG, SOLID/SHIELDED CABLE H J 1-#18 AWG. 2-#14 AWG, FIREMAN'S PHONE CKT, N/A SOUD SINGLE CONDUCTORS GRAPHIC ANNUNCIATOR CKT. SOLID SINGLE CONDUCTORS 2-#14 AWG, SOLID SINGLE CONDUCTORS DOOR HOLDER CKT. N/A N/A N/A N/A W, C. CABLE 728100 W. C. CABLE 729100 N/A W. C. CABLE 728100 N/A N/A N/A K L 4-#16 AWG, SOUD SINGLE CONDUCTORS 8-#24 AWG, SOUD SINGLE CONDUCTORS REMOTE KEYSWITCH CKT. N/A REMOTE LAMP/TEST CKT, N/A N/A N/A N/A N/A M 2-#14 AWG, SOLID SINGLE CONDUCTORS AUDIBLE/VISUAL MASS ALARM CKT, N/A N/A N 2-#16 AWG. SOUD SINGLE CONDUCTORS N/A N/A N/A ALA ACEMENT • 3425 S. 14 T ILA, ,S 0)) 1 EET C.� • 411 0 P Q R 2-#16 AWG, SOUD SINGLE CONDUCTORS 2-#16 AWG. SOUD SINGLE CONDUCTORS AUXILIARY OUTPUT CKT, 24VDC POWER CKT. N/A ELECTRICAL N/A 2-#14 AWG, SOLID SINGLE CONDUCTORS 2-#14 AWG. SOUD SINGLE CONDUCTORS N/A N/A AUXILIARY RELAY CKT. ELECTRICAL S T 2-#16 AWG, SOUD SINGLE CONDUCTORS 8-#24 AWG, SOUD SINGLE CONDUCTORS SERIAL DATA LOOP CKT, ELECTRICAL 1ST & 2ND TELEPHONE LINES N/A U 2-#14 AWG. SOUD SINGLE CONDUCTORS AUDIBLE/VISUAL ALARM CKT. N/A W. C. CABLE 728100 N/A W. C. CABLE 728100 W. C, CABLE 728100 N/A N/A V W 2-#14 AWG, SOUD SINGLE CONDUCTORS N/A X Y 2-#14 AWG. SOUD SINGLE CONDUCTORS 4C-#16 AWG, SOLID/SHIELDED CABLE Z N/A N/A N/A N/A N/A 1 'XA' LOOP CKT. 2-#14 AWG. SOUD SINGLE CONDUCTORS 2-#14 AWG, SOUD SINGLE CONDUCTORS N/A N/A N/A N/A N/A N/A N/A N/A CAUTION; !!! CIRCUIT COUNTS BETWEEN DEVICES SHOWN ON FLOOR PLANS APE PROVIDED FOR CONVENIENCE ONLY AND ARE NOT GUARANTEED TO BE 100% ACCURATE, SEE ATTACHED WIRING DIAGRAMS & FACTORY DATA SHEETS FOR PROPER CIRCUIT CONNECTIONS. FOR ASSISTANCE, CALL! AUTOMATED COMMUNICATIONS CORP,1-(253)-926-1947 EXAMPLE: (CIRCUIT COUNT SYSTEM) CONVENTIONAL 104-10.0NE. AUDIBLE/VISUAL ALARM CKT. 11(.1* WO DETECTION CKTS. EXAMPLE: (CIRCUIT COUNT SYSTEM) ' ANALOG DNE 24 VDC POWER CKT. 10•T WO SPEAKER CKT, THIRD AUDIBLE/VISUAL ALARM CKT, TWO ANALOG CKTS. EXAMPLE; (DEVICE NUMBERING SYSTEM) CONVENTIONL f -q -0 -7TH DEVICE CONNECTED IN THE CIRCUIT, (CONNECTED IN SEQUENCE) ZONE #2 -aCIRCUIT TYPE (DETECTION) EXAMPLE: (DEVICE NUMBERING SYSTEM) ANALOG 9TH DEVICi:, CONNECTED TO ANALOG XMITTER ANALOG XMITTER POINT #7 ANALOG LOOP CIRCUIT ANALOG Gk OUP; OR ZONE #2 CIRCUIT TYPE (ANALOG) 1 0 L- .71- d- O� 0 0 _ 2 co Q 0, co O O) C z O u7 z� _ O W 0 jj N Li C u > -E _I O 0 0 N U 0) L. 0 U U M E < NI O O O z O O a � 1 ft I 0 c 0 Without Comments As Noted in Red O Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Oureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The re.sponsibIlity for the adequacy of design rests totally with the designer, Additions, deletions or revisions tt these drawings ;after this date will void this acceptance; and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: -C-1 2 -10 By:_,... 111. FA 1.0 FA2.1 FA2.2 FA3.0 SHEET LEGEND: BILL OF MATERAIL, MOUNTING ELEVATIONS, & GENERAL NOTES FIRST LEVEL FLOOR PLAN SECOND LEVEL FLOOR PLAN & ABOVE CEILING SECOND L 'VEL FLOOR PLAN RISER AND FEILD WIRING DIAGRAMS REV A REV. NO.: 5/13/2K1 0 DATE: rzi czi LLi —1 U FIRE ALARM SUMMARY.' 01. EXISTING FIRE ALARM SYSTEM PRIMARY POWER IS 120VAC AND SECONDARY POWER BY BATTERY BACKUP ONLY. 02, REPLACE EXISTING ZONAL FIRE ALARM SYSTEM WITH NEW ADDRESSABLE FIRE ALARM SYSTEM AND ALL EXISTING FIRE ALARM DEVICES. 03. REPLACE EXISTING KNOX BOX (FIRE DEPT BOX) WITH NEW KNOX BOX PER FIRE MARSHAL. ad�dre$54iLe locall�/4 k ' ( 4-� l s },�-�►'„ U •L • t¢ -1-rN, f S !-CV(-fo\, Ihov; ✓ r e q v.> i 1,slivl( 6reSke✓ 114,,0tte G1ccw.P s oil Gett.(44 i i4 GP dl P.S . cwt./A-- breul.w5 -%-e. r%eri-• Kw01( Key &0>< . 1U1'W1LA FIRE DEPARTM/N1 Please call: 575.4407 and give this job No. /0- . F 080 and exact address for shut. town or r estoratten e.oprovaV SMOKE DETECTOR <USE DEEP 4S BACKBOX WITH W/ROUND MUDRING) HORN/STROBE <USE 4S 2-1/8" DEEP BACKBOX FOR SPEAKER OR HORN) <SEE MOUNTING DETAIL SHEET FA3,0) HEAT DETECTOR. USE DEEP 4S BACKBOX WITH W /ROUND MUDRING) FIRE ALARM PANEL GUTTER BOX I I POWER BOOSTER NOTE: DO NOT USE BOTTOM KNOCKOUTS USE SIDES & TOP ONLY. (BOTTOM IS RESERVED FOR BATTERIES PLACEMENT FIRE ALARM PANEL e STROBE (USE 4S BACKBOX) 0 HORN/STROBE :USE 4S 2-1/8" DEEP BACKBOX WITH W/ROUND MUDRING) ADDRESSABLE MODULE (USE 2-1/8" DE' P 4S BOX) NOTE: DO NOT USE BOTTOM KNOCKOUTS USE SIDES & TOP ONLY, (BOTTOM IS RESERVED FOR BATTERIES PLACEMENT REMOTE ANNUNCAITOR MANUAL STATION (USE DEEP 4S BACKBOX WITH SINGLE GANG MUD -RING) 48" PER (ADA) REQ. 54" 72" REQ. CLG, CLG. 80" PER CADA) REQ. I'I i1 kr: AI, RM M liNTING E L E VA TI 11 N S (TYPICAL) NOTICE A completed, signed, Tukwila Fire Department Pre-test; Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and. Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. 9 ALA SYSTEM �z0 U co 0 .0 I- r) (3 D 0 w 1-1Pza Cb C44 CS F1,4 0O q O Lu 0 4 0 00 0 w GQ CO ••• U A A A A A R E N EOL rDWP xx • ANN ** ** ** 6 6 8 10 11 4 7 52 4 2 18 17 16 15 14 14 13 12 11 10 9 8 7 6 5 SR P2RK P2R PC2R ATD-HL2F/ADB-FL ATD-L2F/ADB-FL ATD-RL2F/ADB-FL MS-7AF ASD—PL2F/ADB—FL LCD -7100 NP7-12 4 AL1002ULADA REV. NO. SYMBOL QTY. ITEM MODEL NO. REPLACE EXISTING FIRE ALARM DEVICE WITH NEW EXISTING FIRE ALARM DEVICE NEW FIRE ALARM DEVICE END OF LINE RISISTER WALL 75cd STROBE (4S BOX) WP WALL HORN/75cd STROBE WITH (WP BOX) WALL HORN/75cd STROBE (4S BOX) CEILING HORN/75cd STROBE ANALOG 190' FIXED DETECTOR W/BASE ANALOG 135' FIXED DETECTOR W/BASE(4S BOX) ANALOG 135° RATE OF RISE DETECTOR W/BASE ADDRESSABLE MANUAL STATION (4S W/1 -GANG RING) ANALOG SMOKE DETECTOR W/BASE(4S BOX) REMOTE ANNUNCIATOR 7.OAH BATTERIES BACKUP FOR NAC PANEL 10,0 AMP POWER BOOSTER PANEL 18.OAH BATTERIES BACKUP FOR FIRE ALARM PANEL BATTERY CABINET FIRE ALARM PANEL WITH DIALER EXISTING EXISTING AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP co co DESCRIPTION BILL OF MATERIAL SUPPLIER U W O DWG.TITLE teDN E-4 W Lb44 W Lb44ti ,,r24 4-4 w >- U) w 0 U ,..- i ,I a.asa::: @42 ... REMOTE ANNUNCAITOR MANUAL STATION (USE DEEP 4S BACKBOX WITH SINGLE GANG MUD -RING) 48" PER (ADA) REQ. 54" 72" REQ. CLG, CLG. 80" PER CADA) REQ. I'I i1 kr: AI, RM M liNTING E L E VA TI 11 N S (TYPICAL) NOTICE A completed, signed, Tukwila Fire Department Pre-test; Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and. Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. 9 ALA SYSTEM �z0 U co 0 .0 I- r) (3 D 0 w 1-1Pza Cb C44 CS F1,4 0O q O Lu 0 4 0 00 0 w GQ CO ••• U A A A A A R E N EOL rDWP xx • ANN ** ** ** 6 6 8 10 11 4 7 52 4 2 18 17 16 15 14 14 13 12 11 10 9 8 7 6 5 SR P2RK P2R PC2R ATD-HL2F/ADB-FL ATD-L2F/ADB-FL ATD-RL2F/ADB-FL MS-7AF ASD—PL2F/ADB—FL LCD -7100 NP7-12 4 AL1002ULADA REV. NO. SYMBOL QTY. ITEM MODEL NO. REPLACE EXISTING FIRE ALARM DEVICE WITH NEW EXISTING FIRE ALARM DEVICE NEW FIRE ALARM DEVICE END OF LINE RISISTER WALL 75cd STROBE (4S BOX) WP WALL HORN/75cd STROBE WITH (WP BOX) WALL HORN/75cd STROBE (4S BOX) CEILING HORN/75cd STROBE ANALOG 190' FIXED DETECTOR W/BASE ANALOG 135' FIXED DETECTOR W/BASE(4S BOX) ANALOG 135° RATE OF RISE DETECTOR W/BASE ADDRESSABLE MANUAL STATION (4S W/1 -GANG RING) ANALOG SMOKE DETECTOR W/BASE(4S BOX) REMOTE ANNUNCIATOR 7.OAH BATTERIES BACKUP FOR NAC PANEL 10,0 AMP POWER BOOSTER PANEL 18.OAH BATTERIES BACKUP FOR FIRE ALARM PANEL BATTERY CABINET FIRE ALARM PANEL WITH DIALER EXISTING EXISTING AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP AUTOCOMCORP co co DESCRIPTION BILL OF MATERIAL SUPPLIER U W O DWG.TITLE teDN E-4 W Lb44 W Lb44ti ,,r24 4-4 w >- U) w 0 U /44 - i p110�' A030A48 AD30A47 AD3OA49 •B3-3 7' -0" INSIDE STAIRS OUTSIDE STAIRS 1'-6" BEAMS 10'-6" 19,-0" • ar 4 "°26 -0" A030A50 B3-5(EOL) 110 AD30A51 1W�wgy�y,�'! �.w+v:iMwMN\.,xW�»rMwuML.MI",TMw'IvhM AD30A46 110 1B -17 NORTH NORTH SECTIONAL •LAN C; :E: 1/8"—r-0" [) F''.ATC: I-1 OF FI i To Fi (. 6 > a g.)4 t,".. o cr Tael �fZ A[ tpA6 AD 1 0A2 AD30A45 N B3-2 AD30A44' • WP 1B AD I OA28 ,_4„, AD10A2 R AOt0A27 18 AD 10A29 AM1OA10 ,'AD10AS1 ,AD10A13 IR 26'-0" RE 1HIv1 AD10A14 R AD30A52 1B fWsyvwan+Aus,ivWr vwMrw.Ir».a.m•m.w «. . . rvy,.........ww•,wy »,,..u.+w.- rv.v....+.wx nA•..vw,...x•....•✓vv......+wr...uw,..»...a .,...�......... .........w......*1•rY unwww.wx'u•r.+•. Yn.uYl•4.•AW» •....•••••••••••••••••••••••••,. wu...r.M+•ix,rr•+•a..Hw .•x..xN+.w... w MMa B3-4 110 AD30A53 AM30A52 R' AD30A54 AD10A17 A010A3 STORAGE AD10AI8 AD1?: ADI AD1 0AR35 aow,•.»ww•+, +4. 4.41w..W..D.mww... 4.444wnnwu w...a114,10.14••• • ?.w.+w:1. w..rw"w".a,wm*+rsw...,..•..ax++��-w,.•ow�wawww.wxsawa.a:"...M••. N ADIOA19 oseso LI reo4 EXISTING SYMBOL LIST: L.a►° it, r' • & 1�� .. ! & a;w. I 3) v., 1,4 ' I E L.L. `I".* o .t REPLACE WITH WP HORN/STROBE 6i140, NAC BOOSTER PANEL THE FOLLOWING IS EXISTING WIRE USED. •• HA g../41 LICT w Z L L (?1 ,C/' b c - to Loz L L 11 /erpt.. / r F� o FIRE ALARM PLAN GENERAL .NOTE: 1, "WARNING I!! LOOP ZONES & ADDRESSES (AD1A1) HAVE BEEN PROVIDED FOR PREPROGRAMMING OF THE FIRE ALARM SYSTEM. DO NOT CHANGE ANY ZONES OR ADDRESSES (AD1A1) WITHOUT NOTIFYING AUTOMATED COMMUNICATIONS CORP. (253)926-1947. 2. "WARNING !!!" HORN, STROBE, & HORN/STROBE HAVE TAP SETTING, SET HORN TO TEMPORAL, ELECTRO, HIGH 83db, TAP & SET STROBE TO 75cd. TAP. SEE HORN/STROBE DETAIL SHEET (FA3,0) DO NOT CHANGE ANY TAP SETTING WITHOUT NOTIFYING AUTOMATED COMMUNICATIONS CORP. (253)926-1947. FIRE ALARM PLAN NOTES: QQ ELECTRICAL CONTRACTOR TO REUSE ALL EXISTING WIRE IF POSSIBLE. EXTEND EXISTING WIRES AS REQUIRE AND SHOWN ON DRAWING. 0 ELECTRICAL CONTRACTOR TO REPLACE ALL FIRE ALARM DEVICES WITH NEW ADDRESSABLE DEVICES. ® ELECTRICAL CONTRACTOR TO REPLACE ALL HORNS AND BELL WITH NEW HORN/STROBES AND STROBES. ® ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT AS REQUIRE.' Q5 ELECTRICAL CONTRACTOR TO EXISTING REMOTE ANNUNCIATOR WITH NEW LCD DISPLAY REMOTE ANNUNCIATOR. RELOCATED EXISTING REMOTE ANNUNCIATOR TO OUR NEW LOCATION SHOWN ON DRAWING, EXTEND EXISTING WIRES TO NEW LOCATION AS REQUIRED, ® ELECTRICAL CONTRACTOR TO RELOCATE EXISTING PULL STATION TO NEW OUR LOCATION SHOWN ON DRAWING. EXTEND EXISTING WIRES TO NEW LOCATION AS REQUIRED. E O N zoo co L I O) O Z�.�O Jr� U 1-0 O �- z\� S ,O O �j N LL E L� U Q h O l El W LLJ _I CO U N a U (3) O � U U E (L�O z° LC' O CL SHEET NO.: O z 0 0310-07 REV A 5/13/2K10 REV. NO.: DATE: Pal ti ENGR.:EIMD YOUNG C H K' D BY: STEVE YOUNG APPV'D BY: STEVE YOUNG 44 C4 tt� cl 44CTT�� 44 E-1 C1 CL4 E`4 `^wry l Pte. C1 _ N DWG.TITLE FIRE ALARM 0 z CUSTOMER CUSTOMER: EXISTING EXISTING AD40A94 AD40A93 AD40A92 R 1A pp NNr• pp MM DR�PTCEILING EXISTING ABOVE. CEILMNOG HEAT $DEFOLCT ORS TYPICAL. AD40A99 EXISTING AD40A98EXISTING , p AD40A97 EXISTING 1 R 1A M UNTCpEILN ( DROP ING EXISTING EXISTING ,D40A91 AD40A90 4I QQ1 A MMpp NN 1 App 1r EI LING DR�PTCEILING EXISTING AD40A96 EXISTING AD40A95 EXISTING HOMERUN TO FCP DN NORTH ABOVE CEILING SECON%/ LE VEL FLOOR PLAN SCALE: 1 /8"=1'-0" OFFICE 1;TO F.AC E OFFICE EXISTING HOMERUN TO FC P DN EXISTING AD20A64 EXISTING 1 AD20A63 EXISTING EXISTING • EXISTING AD20A62 AD20A65 R AD20A61 EXISTING AD20A60 EXISTING N 82-2 2B EXISTING EXISTING R ® AM20A65 EXISTING AD20A68 EXISTING AD20A67 AD20A66 AM20A66 N 1A AD20A7 EXISTING EXISTING B2-9(EOL) EXISTING EXISTING AD20A69 AD20A73 N AD20A70 R SE C 0 N 1 LF, VEL FL IO' :'GAN NORTH SCALE: 1 /8"=1'-0" I..I;:;I fA !I T L Cr C) r FIRE ALARM PLAN GENERAL NOTE: 1. "WARNING !!!" & LOOP ZONES ADDRESSES (AD1A1) HAVE BEEN PROVIDED FOR PREPROGRAMMING OF THE FIRE ALARM SYSTEM. PO NOT CHANGE ANY ZONES OR ADDRESSES (AD1A1) WITHOUT NOTIFYING AUTOMATED COMMUNICATIONS CORP. (253)926-1947. 2. "WARNING III" HORN, STROBE, & HORN/STROBE HAVE TAP SETTING. SET HORN TO TEMPORAL, ELECTRO, HIGH 83db. TAP Sc SET STROBE TO 75cd. TAP. SEE HORN/STROBE DETAIL SHEET (FA3.0) DO NOT CHANGE ANY TAP SETTING WITHOUT NOTIFYING AUTOMATED COMMUNICATIONS CORP. (253)926-1947. FIRE ALARM PLAN NOTES: QQ ELECTRICAL CONTRACTOR TO REUSE ALL EXISTING WIRE IF POSSIBLE. EXTEND EXISTING WIRES AS REQUIRE AND SHOWN ON DRAWING. • ELECTRICAL CONTRACTOR TO REPLACE ALL FIRE ALARM DEVICES WITH NEW ADDRESSABLE DEVICES. QQ ELECTRICAL CONTRACTOR TO REPLACE ALL HORNS AND BELL WITH NEW HORN/STROBES AND STROBES, ® ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT AS REQUIRE. Qs ELECTRICAL CONTRACTOR TO EXISTING REMOTE ANNUNCIATOR WITH NEW LCD DISPLAY REMOTE ANNUNCIATOR. RELOCATED EXISTING REMOTE ANNUNCIATOR TO OUR NEW LOCATION SHOWN ON DRAWING. EXTEND EXISTING WIRES TO NEW LOCATION' AS REQUIRED. © ELECTRICAL CONTRACTOR TO RELOCATE EXISTING PULL STATION TO NEW OUR LOCATION SHOWN ON DRAWING. EXTEND EXISTING WIRES TO NEW LOCATION AS REQUIRED. 0 E o C\I U Z 03 I a L Q7 N o O O O CD Z N = a (./) ' ' O L. N E ❑ E. 0 S✓ d r o E w F_ U w O _ ( C\1 U CD P". ^ v "' E Q Ln O O.z O oCL O z W W 44 O z O 0 .REV A 5-13-2K1 REV. NO.: DATE: ENGR.:BRAD YOUNG DRAWN. BY: BRAD YOUNG CHK'D BY:STEVE APPV'D BY: STEVE YOUNG W 0 ROOF CORP FIRE ALARM REPLACEMENT STREET TUKWILA, WA 98168 3425 S. 146TH DWG.TITLE: FIRE ALAR O CUSTOMER ROOF 'CORP w 0 (f) U TO FIRE ALARM -4 J -BOX OR PANEL (SEE RISER) rz F, HORN do STROBE (ADA) UGHT (TYPICAL) EOL K) BSTR PNL #1 AUDIBLE/VISUAL CKT. #1 (TYPICAL) ANALOG PHOTO, SMOKE DETECTOR (TYPICAL) A1P AlN To— L_ '`-MANUAL STATION (TYPICAL) A'A':YI FIELD WI /1 INIT. ADDRESSABLE CKT. (TYPICAL) EAT SMOKE DETECTOR (TYPICAL) ING DIAG SCALE: NONE (ROOF ATTIC 1ND IA ANALOG CKT. A - 3RD LEVEL NAC CKT. 02 - 2ND LEVEL (EOL) ANALOG CKT. A - 2ND LEVEL NAC CKT. #3 - 1ST LEVEL WAREHOUSE(EOL) NAC CKT. #1 - 1ST LEVEL (EOL) ANALOG CKT. A - IST LEVEL IP,1S TO REMOTE ANNUNCIATOR #1 PHONE LINE 2 EA, RJ3IX (3 PHONE LINE JACKS REQUIRED. SUPPLIED BY OWNER, 2R (SEE DETAIL THIS SHEET) (COMMON ALARM SIGNAL (;.i TO HVAC CONTROLLER COORDINATE WORK WITH OCY POWER TO 120 VAC, 20 -AMP. (DEDICATED BREAKER). HVAC CONTRACTOR.) © 11ST FIRE RIS ER DI GRA SCALE: NONE FIRE ALARM PLAN GENERAL NOTE: 1. "WARNING III" LOOP ZONES & ADDRESSES (AD1A1) HAVE BEEN PROVIDED FOR PREPROGRAMMING OF THE FIRE ALARM SYSTEM, DO NOT CHANGE ANY ZONES OR ADDRESSES (AD1A1) WITHOUT NOTIFYING AUTOMATED COMMUNICATIONS CORP. (253)926-1947. 2, "WARNING III" HORN, STROBE, & HORN/STROBE HAVE TAP SETTING. SET HORN TO TEMPORAL, ELECTRO, HIGH 83db. TAP & SET STROBE TO 75cd. TAP. SEE HORN/STROBE DETAIL SHEET (FA3.0) DO NOT CHANGE ANY TAP SETTING WITHOUT NOTIFYING AUTOMATED COMMUNICATIONS CORP. (253)926-1947. FIRE ALARM PLAN NOTES: Qi ELECTRICAL CONTRACTOR TO REUSE ALL EXISTING WIRE IF POSSIBLE, EXTEND EXISTING WIRES AS REQUIRE AND SHOWN ON DRAWING, ® ELECTRICAL CONTRACTOR TO REPLACE ALL FIRE ALARM DEVICES WITH NEW ADDRESSABLE DEVICES. © ELECTRICAL CONTRACTOR TO REPLACE ALL HORNS AND BELL WITH NEW HORN/STROBES AND STROBES. ® ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT AS REQUIRE. Qs ELECTRICAL CONTRACTOR TO EXISTING REMOTE ANNUNCIATOR WITH NEW LCD DISPLAY REMOTE ANNUNCIATOR, RELOCATED EXISTING REMOTE ANNUNCIATOR TO OUR NEW LOCATION SHOWN ON DRAWING. EXTEND EXISTING WIRES TO NEW LOCATION AS REQUIRED, © ELECTRICAL CONTRACTOR TO RELOCATE EXISTING PULL STATION TO NEW OUR LOCATION SHOWN ON DRAWING. EXTEND EXISTING WIRES TO NEW LOCATION AS REQUIRED. TO TEL. LINE ttl FFflhrl FINE PANFI. Mn r..Ir I. 736o f LJ ILL. LINE. t12 ERIIM f IPF P6111 -.l N11J11LL Jrsfi rf 10 c.:u TOMLF•: PHOI\JF 77-11"-- -r- • T H.J;31 X • I'.JJIX PLr,CC !PI HI IT 11'Ih9. I C". C1 STOMER 1 6E:. PUN:CII'DO'MI•J I r l,iCK O. OTI IEr s I INF All LINE AP LINE BD LINE DR LU C Dr I E ruNC1I DOWN I v// ORANC,l• r'1 (YiF BLOCK LHf of HI -RS 1 1:11 :1 LINE A -OU•I LINL A I:L-71.:f,..NI !J : FD BY (J :TQMFR PFR PIFP'A 2. MOUNT R.13 1 >; WITHIN ONE FOOT OF THE FIRE ALARM PANEL. MOM FIRE AL RM TELEPHONE L !! Y/ UT DETAIL SCALE: NO SCALE E.C. TO TURN SWITCH TO 15/75cd. EINoF ImImI E.C. TO SET JUMPERS TO PC1-ON, PC2-OFF, AND PC3-OFF. E,C. TO TURN SWITCH TO 15/75cd. NOTE: E.C. TO SET JUMPERS, SWITCH, & PUT SKICKERS ON HORN/STROBE BEFORE INSTALLATION. SEE CUT SHEET OR INSTALLAION MANUAL FOR MORE INSTRUCTIONS. RN/STROBE DETAIL SCALE: NONE 0 E O c - o. L co CO O ❑ °'E Z O 0Olj O zLN� = O L O N Li E a cr O E ❑ Cr) C3� r E o CD U N Q U°'0 Cr: Quo -`"QUO N Z in0 u .771 z Ld LU Z C) REVA 5-13--2K16 REV. NO.: DATE: -J Li •• W W X \ (f) CN 0 , �. C.0 c9 ° 0 � N J Ute\ f: 17- O X O D cD L) W 0 w 0 0 ROOF CORP FIRE ALARM REPLA CEMENT c/� C1 CO 3425 S. 146TH STREET TUKWILA, WA DWG.TITLE: DIA GRAMS rza Lza ENGR.:BRAD 0 0 BY:BRAD YOUNG 1L w >- w CO >- 0 0 0 CUSTOMER BY: STEVE YOUNG 0 0 ROOF CORP CUSTOMER: FIRE ALARM GENERAL NOTES: 01, CAUTION; - THIS SYSTEM DESIGN IS BASED ON CONTRACT DRAWING AND AUTOMATED COMMUNICATIONS CORP.. ("AUTOMATED"), SYSTEM CONFIGURATION AS OF THE DATE OF THE LATEST REVISION TO THESE DRAWINGS. AUTOMATED MUST BE CONSULTED PRIOR TO CHANGING CONTRACT DRAWING, SUCH CHANGES MAY EFFECT SYSTEM CONFIGURATION, INTENDED DESIGN OR THE SYSTEM'S PROPER PERFORMANCE, 02. IDENTIFYING NUMBERS ADJACENT TO A DEVICE SYMBOL DENOTES ORDER OF WIRING. (ie: DEVICE NUMBER "X1-2". "X" IDENTIFIES THE CIRCUIT DESIGNATION, "1" IDENTIFIES . THE CIRCUIT NUMBER, AND "-2" IDENTIFIES THE DEVICE AS THE SECOND DEVICE CONNECTED TO THE CIRCUIT. 03. THE CIRCUIT ROUTING AND WIRING COUNTS (IF SHOWN) ON THE FLOOR PLAN DRAWINGS ARE SHOWN DIAGRAMMATIC BASED ON CONTINUOUS AND SHORTEST POSSIBLE ROUTING FROM THE CONTROL PANEL AND BETWEEN CONNECTED FIELD DEVICES WITH NO PHYSICAL OBSTRUCTIONS. THE WIRE OR CIRCUIT COUNTS (IF SHOWN) ARE PROVIDED AS A CONVENIENCE ONLY AND AS A MEANS TO HASTEN INSTALLATION OR TO DETERMINE CONDUIT FILL. HOWEVER, WIRE OR CIRCUIT COUNTS ARE NOT GUARANTEED TO BE FREE OF ERRORS. INSTALLER MUST BE THOROUGHLY FAMILIARIZED WITH EACH DIFFERENT TYPE OF CIRCUIT AND ITS CIRCUIT SUPERVISORY REQUIREMENTS. REFER TO FIELD WIRING DIAGRAM AND DEVICE MANUALS FOR CORRECT CIRCUIT REQUIREMENTS IN CONJUNCTION WITH REQUIRED CIRCUIT ROUTING. FOR TECHNICAL QUESTIONS, CALL AUTOMATED'S PROJECT ENGINEER AT PHONE 1-(253)-926-1947, 04. "AS -BUILT" DRAWING ARE REQUIRED FOR THIS PROJECT. SUBMIT "AS -BUILT" DRAWINGS OF CONDUIT ROUTING AS WELL AS CIRCUIT ROUTING TO AUTOMATED AS SOON AS POSSIBLE. THIS INFORMATION IS REQUIRED TO BE PART OF THE "OWNER'S OPERATION MANUALS', FAILURE TO SUBMIT "AS -BUILT" INFORMATION WILL CAUSE DELAY IN PROJECT CLOSEOUT. 05. FACTORY RECOMMENDED MINIMUM WIRE SIZES, TYPE AND CONSTRUCTION AS NOTED ON THE FOLLOWING CHARTS (LEGEND: CIRCUIT DESIGNATION) MUST BE STRICTLY FOLLOWED. ANYONE WISHING TO MAKE CHANGES WILL DO SO AT THEIR OWN RISK 111 06. ALL WIRING AND INSTALLATION SHALL CONFORM WITH THE LATEST U.L., N.E.C., N.F.P.A., W.A.C., AND OTHER STANDARDS AS APPLICABLE. 07. CIRCUITS OTHER THAN THOSE SHOWN ON THESE DRAWINGS SHALL NOT OCCUPY THE SAME CONDUIT RACEWAYS. (FOR CIRCUITS INSTALLED IN CONDUITS ONLY) 08, RELAY CONTACTS ARE SHOWN IN NORMAL (NON -ALARM) POSITION WITH POWER APPLIED TO THE CONTROL PANEL AND THE PANEL IN NORMAL SUPERVISORY MODE. 09. THESE DRAWINGS, ALONG WITH MANUFACTURE'S DATA SHEETS ARE PREPARED AND SUBMITTED BY AUTOMATED'S ENGINEERING DEPARTMENT AND ARE BASED ON ITS' INTERPRETATION OF THE SPECIFIED FUNCTIONAL DESIGN CRITERIA THOSE ITEMS THAT ARE NECESSARY TO BE SHOWN IN AUTOMATED DRAWINGS AND MANUFACTURER'S DATA SHEETS, BUT ARE SPECIFIED TO BE "PROVIDED BY OTHERS" IN OTHER SPECIFICATION SECTIONS, ARE INTENDED TO BE "PROVIDED BY OTHERS". 10. WHEN NECESSARY, DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY AVAILABILITY, ETC. AUTOMATED RESERVES THE RIGHT TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED, WITH EQUIPMENT OF EQUAL OR BETTER QUALITY, FUNCTION AND DESIGN, 11. INSTALLING ELECTRICIAN SHALL IDENTIFY AND LABEL AND TAGGED ALL CIRCUITS, CABLES AND CONDUCTORS AT THE CONTROL PANEL, DATA GATHERING PANEL, TIEBOX LOCATIONS AND AT REMOTE TERMINAL JUNCTION BOXES. HENCE, ALLOW AT LEAST ONE WEEK LEAD TIME PRIOR TO AUTOMATED'S VISIT FOR FINAL CONTROL PANEL HOOKUP AND CIRCUIT TESTS FREE OF ALL OPENS, SHORTS, AND GROUNDS. FAILURE TO DO SO WILL RESULT IN BACK CHARGES TO CUSTOMER FOR UNNECESSARY VISIT AND DELAY PROJECT FINAL TEST WITH THE AHJ. ELECTRICAL CONTRACTOR SHALL FAMILIARIZE AUTOMATED TECHNICIAN WITH ALL NECESSARY INFORMATION PERTINENT TO THE INSTALLATION INCLUDING IDENTIFICATION OF CIRCUITS, CONDUITS AND WIRING, OR ANY DEVIATION REFLECTING CHANGES FROM THESE DRAWING. 12. SMOKE DETECTORS HAVE BEEN POSITIONED AT MAXIMUM OF 15 -FT. FROM THE FARTHEST WALL AND SPACED 30 -FT. APART CENTER -TO -CENTER AS APPROPRIATE, WITHOUT REGARDS TO ANY OBSTRUCTIONS, OR ANY NEARBY EQUIPMENT THAT MAY HINDER THE DETECTOR'S EFFECTIVENESS (ie: AIR SUPPLY REGISTERS, LOW BEAMS, ETC.). REFER TO 2007 NFPA 72 CONCERNING PROPER PLACEMENTS OF SMOKE OR HEAT DETECTORS,OR BEAM OBSTRUCTION DETECTORS. NOTIFY AUTOMATED REGARDING ALL NECESSARY CIRCUIT CHANGES, ADDITIONAL OR DELETED DEVICES, THAT MAY BE NECESSARY TO FOLLOW THE CODE OR AHJ. 13, AUDIBLE AND VISUAL ALARM INDICATING APPLIANCES HAVE BEEN STRATEGICALLY LOCATED FOR MAXIMUM VISIBILITY TO MEET A.D.A. REQUIREMENTS AND AUDIBILITY TO MEET AHJ, REQUIREMENTS. DO NOT RELOCATE THESE DEVICES IF AT ALL POSSIBLE. IF IT BECOMES NECESSARY TO RELOCATE, PLEASE CALL AUTOMATED PROJECT ENGINEER FOR ADVICE. PHONE: 1-(253)-926-1947, 14, IN AN EFFORT TO REDUCE NUISANCE ALARMS AND MAINTAIN SMOKE DETECTOR SENSITIVITY, THE FIRE MARSHALS OFFICE IS GOING TO BE ENFORCING CHAPTER 2 INITIATING DEVICES, SECTION 2-3.6.1.3 OF THE 2007 NFPA 72. THIS SECTION REQUIRES SMOKE DETECTOR INSTALLATION AFTER THE CONSTRUCTION CLEAN UP OF ALL TRADES IS COMPLETE AND FINAL. IT SHOULD BE NOTED THAT THIS REQUIREMENT APPLIES TO SMOKE DETECTOR INSTALLATION ONLY AND NOT OTHER TYPES OF DEVICES. THIS REQUIREMENT APPLIES TO THE SMOKE DETECTOR HEAD ONLY. THE WIRING AND SMOKE DETECTOR BASE MAY BE INSTALLED PRIOR TO CLEAN UP. AS A REMINDER, DO NOT CALL FOR YOUR FINAL INSPECTION UNTIL THE ENTIRE FIRE ALARM SYSTEM IS OPERATIONAL AND HAS BEEN PRE -TESTED IN ACCORDANCE WITH CHAPTER 7, INSPECTION, TESTING, AND MAINTENANCE, OF THE 2007 NFPA 72, THE RECORD OF COMPLETION IN ACCORDANCE WITH CHAPTER 1, FUNDAMENTALS OF FIE ALARM SYSTEMS, SECTION 1-6.2.1 OF THE 2007 NFPA 72, SHALL BE AVAILABLE TO THE INSPECTOR ON FINAL FIRE ALARM SYSTEM INSPECTION. 15, ELECTRICAL CONTRACTOR TO PROVIDE A GUTTER ABOVE TWO OR MORE FIRE ALARM PANELS. "WARNING !1!" DO NOT USE BOTTOM KNOCKOUTS USE UPPER SIDES & TOP ONLY!!! OF THE FIRE ALARM AND BOOSTER PANELS. (THE BOTTOM OF THE PANELS ARE RESERVED FOR BACKUP BATTERIES PLACEMENT). LEGEND: (CIRCUIT DESIGNATIONS/DESCRIPTIONS) DESIG: CIRCUIT REQUIREMENTS: A B C D E 2-#16 AWG. SOUD SINGLE CONDUCTORS 2-#14 AWG. SOUD SINGLE CONDUCTORS 2C-#16 AWG. SOUD/SHIELDED CABLE 2-#16 AWG. SOUD SINGLE CONDUCTORS F G 2-#14 AWG. SOLID SINGLE CONDUCTORS 4C-#16 AWG, SOLID/SHIELDED CABLE CIRCUIT DESCRIPTIONS: ANALOG SIGNAUNG UNE CKT, AUDIBLE/VISUAL ALARM CKT. AUDIO (SPEAKER) ALARM CKT. DETECTION CKT. ELEVATOR RECALL CKT. PROVIDED BY: ELECTRICAL ELECTRICAL N/A ELECTRICAL N/A REFERENCE: W. C. CABLE 728100 W. C. CABLE 729100 N/A W. C. CABLE 728100 N/A TACEMENT FIREMAN'S PHONE CKT. N/A N/A 1—#18 AWG. SOUD SINGLE CONDUCTORS GRAPHIC ANNUNCIATOR CKT. N/A H 2-#14 AWG. SOUD SINGLE CONDUCTORS DOOR HOLDER CKT. N/A J K 2-#14 AWG, SOUD SINGLE CONDUCTORS 4-#16 AWG. SOLID SINGLE CONDUCTORS N/A REMOTE KEYSWITCH CKT. N/A N/A N/A N/A N/A N/A L M 8-#24 AWG. SOUD SINGLE CONDUCTORS 2-#14 AWG. SOLID SINGLE CONDUCTORS REMOTE LAMP/TEST CKT, AUDIBLE/VISUAL MASS ALARM CKT, N/A N/A N/A N/A N 2-#16 AWG. SOUD SINGLE CONDUCTORS N/A N/A 0 P Q 2-#16 AWG, SOLID SINGLE CONDUCTORS 2-#16 AWG. SOLID SINGLE CONDUCTORS AUXILIARY OUTPUT CKT, 24VDC POWER CKT. N/A ELECTRICAL N/A N/A W. C. CABLE 728100 3425 14 ILA 41!) (0)) 1 ir) 2-#14 AWG, SOUD SINGLE CONDUCTORS N/A N/A N/A R S 2-#14 AWG. SOLID SINGLE CONDUCTORS 2-#16 AWG, SOLID SINGLE CONDUCTORS AUXILIARY RELAY CKT, SERIAL DATA LOOP CKT. ELECTRICAL ELECTRICAL W. C. CABLE 728100 W. C. CABLE 728100 T U 8-#24 AWG, SOLID SINGLE CONDUCTORS V W X Y 2-#14 AWG. SOLID SINGLE CONDUCTORS 2-#14 AWG, SOLID SINGLE CONDUCTORS 2-#14 AWG, SOUD SINGLE CONDUCTORS 4C-#16 AWG. SOUD/SHIELDED CABLE 1ST & 2ND TELEPHONE LINES AUDIBLE/VISUAL ALARM CKT. N/A N/A N/A N/A 2-#14 AWG. SOLID SINGLE CONDUCTORS Z 2-#14 AWG. SOLID SINGLE CONDUCTORS 'XA' LOOP CKT. N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A CAUTION: I! CIRCUIT COUNTS BETWEEN DEVICES SHOWN ON FLOOR PLANS ARE PROVIDED FOR CONVENIENCE ONLY AND ARE NOT GUARANTEED TO BE 100% ACCURATE. SEE ATTACHED WIRING DIAGRAMS& FACTORY DATA SHEETS FOR PROPER CIRCUIT CONNECTIONS. FOR ASSISTANCE, CALL1 AUTOMATED COMMUNICATIONS CORP. 1-(253)-926-1947 EXAMPLE: (CIRCUIT COUNT SYSTEM) CONVENTIONAL ID -12.0.01E AUDIBLE/VISUAL ALARM CKT. roJQ. DETECTION CKTS. EXAMPLE: (CIRCUIT COUNT SYSTEM) ANALOG tp 24 VDC POWER CKT. TWO SPEAKER CKT. THIRD AUDIBLE/VISUAL ALARM CKT. ANALOG CKTS. EXAMPLE (DEVICE NUMBERING SYSTEM) CONVENTIONL "'7TH DEVICE CONNECTED IN THE CIRCUIT, (CONNECTED IN SEQUENCE) ZONE #2 ► CIRCUIT TYPE (DETECTION) EXAMPLE: (DEVICE NUMBERING SYSTEM) ANALOG ns 9TH DEVICE CONNECTED TO ANALOG XMITTER ANALOG XMITTER POINT #7 ANALOG LOOP CIRCUIT ANALOG GROUP OR ZONE #2 CIRCUIT TYPE (ANALOG) c0 E 0 U Z CCO i .L. Q O ❑° E z O OU V) L-) z�� = O duo 0 LL N Ll- C CZ 0 I\ 0 0 { u w F - (f) LJ Wit - I 0 9 N U 0 U <(,N 0 O O Z LO • SHEET NO.: O z 0 SMOKE DETECTOR (USE DEEP 4S BACKBOX WITH W/ROUND MUDRING) MUM I II I 11111 HORN/STROBE (USE 4S 2-1/8" DEEP BACKBOX FOR SPEAKER OR HORN) (SEE MOUNTING DETAIL SHEET FA3,0) HEAT DETECTOR USE DEEP 4S BACKBOX WITH W /ROUND MUDRING) FIRE ALARM PANEL GUTTER BOX POWER BOOSTER NOTE: D❑ NOT USE BOTTOM KNOCKOUTS USE SIDES & TOP ONLY. (BOTTOM IS RESERVED FDR BATTERIES PLACEMENT FIRE ALARM PANEL e STROBE (USE 4S BACKBOX) 0 HORN/STROBE CLG. (USE 4S 2-1/8" DEEP BACKBOX WITH W/ROUND MUDRING) ADDRESSABLE MODULE (USE 2-1/8" DEEP 4S BOX) NOTE: D❑ NOT USE BOTTOM KNOCKOUTS USE SIDES & TOP ONLY, (BOTTOM IS RESERVED FOR BATTERIES PLACEMENT i� .Mi 4 A. -Li e REMOTE ANNUNCAITOR MANUAL STATION (USE DEEP 4S BACKBOX WITH SINGLE GANG MUD -RING) 48" PER (ADA) REQ. 54" 72" REQ. 80" PER (ADA) REQ. 1 CLG. FI/b' ALAR ,SII UN TIN G ELEVATI NS T Y "IC4) SHEET LEGEND: FA1.0 FA2. 1 FA2, 2 FA3, 0 BILL OF MATERAIL, MOUNTING ELEVATIONS, & GENERAL NOTES FIRST LEVEL FLOOR PLAN SECOND LEVEL FLOOR PLAY & ABOVE CEILING SECOND LEVEL FLOOR PLAN RISER AND FEILD WIRING DIAGRAMS FIRE ALARM SUMMARY: 01. EXISTING FIRE ALARM SYSTEM PRIMARY POWER IS 120VAC AND SECONDARY POWER BY BATTERY BACKUP ONLY. 02. REPLACE EXISTING ZONAL FIRE ALARM SYSTEM WITH NEW ADDRESSABLE FIRE ALARM SYSTEM AND ALL EXISTING FIRE ALARM DEVICES. 03, REPLACE EXISTING KNOX BOX (FIRE DEPT BOX) WITH NEW KNOX BOX PER FIRE MARSHAL. S—BUILTS REV. NO.: 9/9/2K10 DATE: cvn ALA M SYSTEM o Cei 0 Z w D 4-4 DRAWN. BY: BRAD YOUNG CHK'D BY:STEVE YOUNG S 20 RA400 REMOTE LED STATION (1 -GANG BOX) AUTOCOMCORP 19 SCR CEILING 75cd STROBE AUTOCOMCORP 18 ******* REPLACE EXISTING FIRE ALARM DEVICE WITH NEW EXISTING E N EOL ** 17 ******* EXISTING FIRE ALARM_ DEVICE EXISTING ** 16 ******* NEW FIRE ALARM DEVICE AUTOCOMCORP ** 15 ******* END OF LINE RISISTER AUTOCOMCORP 6 14 SR WALL 75cd STROBE.' (4S BOX) AUTOCOMCORP IoWP 1 14 P2RK WP WALL HORN/75cd STROBE WITH (WP BOX) AUTOCOMCORP 7 13 P2R WALL HORN/75cd STROBE (45 BOX) AUTOCOMCORP 8 12 PC2R CEILING HORN/75cd "'STROBE AUTOCO MCORP 8 11 ATD-HL2F/ADB-FL ANALOG 190' FIXED DETECTOR W/BASE AUTOCO MCORP 9 10 ATD-L2F/ADB-FL ANALOG 135' FIXED DETECTOR W/BASE(4S BOX) AUTOCOMCORP 03) 4 9 ATD-RL2F/ADB-FL ANALOG 135° RATE OF RISE DETECTOR W/BASE AUTOCOMCORP 7 8 MS-7AF ADDRESSABLE MANUAL STATION (4S W/1 -GANG RING) AUTOCOMCORP 55 7 ASD-PL2F/ADB-FL ANALOG SMOKE DETECTOR W/BASE(4S BOX) AUTOCOMCORP aNN 6 LCD -7100 REMOTE ANNUNCIATOR AUTOCOMCORP CI 4 5 NP7-12 7.OAH BATTERIES BACKUP FOR NAC PANEL AUTOCOMCORP 2 4 AL1002ULADA 10.0 AMP POWER BOOSTER PANEL AUTOCOMCORP 2 3 NP18-12 18.OAH BATTERIES BACKUP FOR FIRE ALARM PANEL AUTOCOMCORP REV. NO. 3i SYMBOL QTY. 2 BB -17 1 FCI7100-1 D BATTERY CABINET FIRE ALARM PANEL WITH DIALER DESCRIPTION BILL Qr MATERIAL AUTOCOMCORP AUTOCOMCORP 3425 S. 146TH STREET TUKWILA, WA W W Lb 4.4 W L5 • R "T1 AD30A48 A030A49 B4-2 7'-0" INSIDE STAIRS OUTSIDE STAIRS 1'-6" BEAMS 10'-6" 19' -o" SECTIONAL PLAN SCALE; 1 /8"-1'-o• NORTH f ISP.ATt.l OFFICE R �. • WW/VnignniFfn .w # • welca fatt, 7.aRpui,t) S� Gu c de, we /,.•c 54-k) t 5/A0 v-F��nzg Write-hoo ;401,1,5 Y M 1oi 214 ,'4 e 4, o ✓t C- 2Cn! vv) Ec Q .vorv, 21-4 S'" Vo R y AD1OA5 R AD10A4 R AD 10A7 N AD30A46 AD30A47 110 A030A44 B3-3 AD10A8 WP B4-1 16 1B R AD10A9 AD10A2 AD10A2 R t AD1DA27 1B • •/ >AD10A29 R W^,RLI I0L_I �L TCR.AG E AD 0A41 26'-0" AD10A30 AD1O, 1 R .. AD10A26 OFFICE .3 . ,'AD1OA1 ,R t rA010A25 • R R AD10Al2 A010A24 AD10A,3,2. I R R AD I0A23 10A10 • bY B4-4(EOL) 110 B4-3 110 AD30A51 AD30A52 AD30A63 1B A030A54 • �10A32 ADIOA3L. AD I �a r 34 R AD10A20 R ADi0A22 OFT ICE R AD10A21 AD10A14 ADICA17 AD1DAIS • AD10A37 R AD10A35 AM30A52 aiS • If AD10A19 fivi L at. td e 1.6 A res, EXISTING SYMBOL LIST: f Fz(& NN t)k.b' REPLACE WITH WP HORN/STROBE l Ai IA Aiiw%r it,3 NAC BOOSTER PANEL THE FOLLOWING IS EXISTING WIRE USED. 1461.4.41 ei 451_4_4 Litz L i. 1 , / FIRE ALARM PLAN GENERAL NOTE: 1. "WARNING !!I" LOOP ZONES & ADDRESSES (AD1A1) HAVE BEEN PROVIDED FOR PREPROGRAMMING OF THE FIRE ALARM SYSTEM. DO NOT CHANGE ANY ZONES OR ADDRESSES (AD1A1) WITHOUT NOTIFYING AUTOMATED COMMUNICATIONS CORP. (253)926-1947. 2. "WARNING !!!" HORN, STROBE, & HORN/STROBE HAVE TAP SETTING, SET HORN TO TEMPORAL, ELECTRO, HIGH 83db, TAP & SET STROBE TO 75cd, TAP. SEE HORN/STROBE DETAIL SHEET (FA3.0) DO NOT CHANGE ANY TAP SETTING WITHOUT NOTIFYING AUTOMATED COMMUNICATIONS CORP. (253)926-1947. FIRE ALARM PLAN NOTES: ® ELECTRICAL CONTRACTOR TO REUSE ALL EXISTING WIRE IF POSSIBLE. EXTEND EXISTING WIRES AS REQUIRE AND SHOWN ON DRAWING. ® ELECTRICAL CONTRACTOR TO REPLACE ALL FIRE ALARM DEVICES WITH NEW ADDRESSABLE DEVICES. QQ ELECTRICAL CONTRACTOR TO REPLACE ALL HORNS AND BELL WITH NEW HORN/STROBES AND STROBES. ® ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT AS REQUIRE. ® ELECTRICAL CONTRACTOR TO EXISTING REMOTE ANNUNCIATOR WITH NEW LCD DISPLAY REMOTE ANNUNCIATOR. RELOCATED EXISTING REMOTE ANNUNCIATOR TO OUR NEW LOCATION SHOWN ON DRAWING. EXTEND EXISTING WIRES TO NEW LOCATION AS REQUIRED. - © ELECTRICAL CONTRACTOR TO RELOCATE EXISTING PULL STATION TO NEW OUR LOCATION SHOWN ON DRAWING. EXTEND EXISTING WIRES TO NEW LOCATION AS REQUIRED. 41/ ..sM seityv0 (0 E 0) o ZooI c 0 N O °'E z O 0 ^ U -r° o = o 0 Li E L.. 0 o L,J I-- d- 0) • I o U = N rn s` O LL U E Q c\I• Ln O � w � Ozo oo a 1- Q 0 O 0 u O Z W UJ 0 0 AS --B UIL TS REV. NO.: 9/9/2K1 0 DATE: W •• W W x = N (J (7 Fig 031 0-0711A2- 1 .DWG EN GR.:BRAD DRAWN. BY: BRAD YOUNG CHK'D BY:STEVE YOUNG APPV'D BY: STEVE U W O ROOF CORP FIRE ALARM REPLACEMENT 3425 S. 146TH STREET TUKWILA, WA 98168 DWG.TITLE: CUSTOMER ROOF CORP CUSTOMER EXISTING EXISTING HOMERUN TO FC P DN AD40A93EXISTING AD40A99 EXISTING EXISTING AD40A91 AD40A90 R 1A 1A NR8P TCEILING NROP TCEILING FIRE ALARM PLAN GENERAL NOTE: 1. "WARNING !!!" LOOP ZONES & ADDRESSES (AD1A1) HAVE BEEN PROVIDED FOR PREPROGRAMMING OF THE FIRE ALARM SYSTEM. DO NOT CHANGE ANY ZONES OR ADDRESSES (AD1A1) WITHOUT NOTIFYING AUTOMATED COMMUNICATIONS CORP. (253)926-1947. 2. "WARNING III" HORN, STROBE, & HORN/STROBE HAVE TAP SETTING. SET HORN TO TEMPORAL, ELECTRO, HIGH 83db. TAP & SET STROBE TO 75cd. TAP. SEE HORN/STROBE DETAIL SHEET (FA3.0) DO NOT CHANGE ANY TAP SETTING WITHOUT NOTIFYING AUTOMATED COMMUNICATIONS CORP. (253)926-1947. FIRE ALARM PLAN NOTES: Ot ELECTRICAL CONTRACTOR TO REUSE ALL EXISTING WIRE IF POSSIBLE. EXTEND EXISTING WIRES AS REQUIRE AND SHOWN ON DRAWING, ® ELECTRICAL CONTRACTOR TO REPLACE ALL FIRE ALARM DEVICES WITH NEW ADDRESSABLE DEVICES. Q3 ELECTRICAL CONTRACTOR TO REPLACE ALL HORNS AND BELL WITH NEW HORN/STROBES AND STROBES, ® ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT AS REQUIRE. C) ELECTRICAL CONTRACTOR TO EXISTING REMOTE ANNUNCIATOR WITH NEW LCD DISPLAY REMOTE ANNUNCIATOR. RELOCATED EXISTING REMOTE ANNUNCIATOR TO OUR NEW LOCATION SHOWN ON DRAWING. EXTEND EXISTING WIRES TO NEW LOCATION AS REQUIRED. ® ELECTRICAL CONTRACTOR TO RELOCATE EXISTING PULL STATION TO NEW OUR LOCATION SHOWN ON DRAWING. EXTEND EXISTING WIRES TO NEW LOCATION AS REQUIRED. EXISTING AD40A98 EXISTING AD40A97 EXISTING AD40A96 EXISTING AD40A95 Mouu pp1 A ooUU�� 1A NROPTCEILING DROPTCtILING S-BUILTS REV. NO.: 9/9/2K1 0 DATE: 0 VE CEILING SECOND' ; LE VEL FL Q ® PLAN SCALE: 1 /8':=1 0" EXISTING J EXISTING OFFICE AD20A61 AD20A62 HOMERUIJEXISTING TO 2 FCP R ---�� N BIDN EXISTING P DN EXISTING B2-5 R EXISTING EXISTING N B2-2 2B ® AM20A65 EXISTING B2-1 AD A67 1A R AD20A60 EXISTING 1A EXISTING 4D20A','2 EXISTING �© AD20A94 82-3 N AM20A66 N 1A AD20A75 EXISTING EXISTING 1A AD2DA74 B2-9(EOL) O N 1A 1A 01 .................................... S i' CON' % L ' VEL FL 0 0 /'`L AD20A73 EXISTING EXISTING AD20A69 AD20A71 SCALE: 1/8"=1'-0" NORTH TO FIRE ALARM J -BOX OR PANEL (SEE RISER) HORN & STROBE (ADA) UGHT (TYPICAL) B1-5 ANALOG PHOTO. SMOKE DETECTOR (TYPICAL) EOL (4..7K) BSTR PNL #1 AUDIBLE/VISUAL CKT. #1 (TYPICAL) .FI i' F, ALA SCALE: NONE (ROOF ,ATTIC 2ND 1A J '-MANUAL STATION (TYPICAL) o u is AD1A1 ATD-L2/ADB-FL HEAT SMOKE INIT. ADDRESSABLE CKT. (TYPICAL) EAT SMOKE DETECTOR (TYPICAL) M FIELD WI/ING DIAG/AM ANALOG CKT. A - 3RD LEVEL NAC CKT. #2 - 2ND LEVEL <EOL) ANALOG CKT. A - 2ND LEVEL NAC CKT, #5 - 1ST LEVEL WAREHOUSE RESTROOM<EOL) NAC CKT. #4 - 1ST LEVEL WAREHOUSE(EOL) NAC CKT. #3 - 1ST LEVEL OFFICE<EOL) NAC CKT, 01 - 1ST LEVEL OFFICE(EOL) ANALOG CKT. A - 1ST LEVEL 1P,1S TO REMOTE ANNUNCIATOR #L PHONE LINE 2 EA, RJ31X Q3 #2 PHONE LINE JACKS REQUIRED. SUPPLIED BY OWNER, 2R (SEE DETAIL THIS SHEET) (COMMON ALARM SIGNAL O TO HVAC CONTROLLER COORDINATE WORK WITH HVAC CONTRACTOR.) TO 120 VAC, 20 -AMP. 3 EMERGENCY POWER (DEDICATED BREAKER) 1ST FIRE ALAR RISER DI J GAM SCALE: NONE FIRE ALARM PLAN GENERAL NOTE: 1. "WARNING III" LOOP ZONES & ADDRESSES (AD1A1) HAVE BEEN PROVIDED FOR PREPROGRAMMING OF THE FIRE ALARM SYSTEM. DO NOT CHANGE ANY ZONES OR ADDRESSES (AD1A1) WITHOUT NOTIFYING AUTOMATED COMMUNICATIONS CORP. (253)926-1947. Z. "WARNING 111" HORN, STROBE, & HORN/STROBE HAVE TAP SETTING. SET HORN TO TEMPORAL, ELECTRO, HIGH 83db. TAP &. SET STROBE TO 75cd. TAP. SEE HORN/STROBE DETAIL SHEET (FA3.0) DO NOT CHANGE ANY TAP SETTING WITHOUT NOTIFYING AUTOMATED COMMUNICATIONS CORP. (253)926-1947. FIRE ALARM PLAN NOTES: Qi ELECTRICAL CONTRACTOR TO REUSE ALL EXISTING WIRE IF POSSIBLE. EXTEND EXISTING WIRES AS REQUIRE AND SHOWN ON DRAWING, ® ELECTRICAL CONTRACTOR TO REPLACE ALL FIRE ALARM DEVICES WITH NEW ADDRESSABLE DEVICES. OE ELECTRICAL CONTRACTOR TO REPLACE ALL HORNS AND BELL WITH NEW HORN/STROBES AND STROBES. ® ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT AS REQUIRE. O ELECTRICAL CONTRACTOR TO EXISTING REMOTE ANNUNCIATOR WITH NEW LCD DISPLAY REMOTE ANNUNCIATOR. RELOCATED EXISTING REMOTE ANNUNCIATOR TO OUR NEW LOCATION SHOWN ON DRAWING. EXTEND EXISTING WIRES TO NEW LOCATION AS REQUIRED. © ELECTRICAL CONTRACTOR TO RELOCATE EXISTING PULL STATION TO NEW OUR LOCATION SHOWN ON DRAWING. EXTEND EXISTING WIRES TO NEW LOCATION AS REQUIRED. FFnM FIRE PANFI- 1.1 1 Ih'1 F 1 P ppm- J TO TEL LIN: it1 m nr.. Fl. 7,360 I LJ ILL. LINL tt2 1.Il1'Jl1G1NY MLJl)LL K•J31Y. K.J31: PLPcE JN:I' NN HI11 10H. 10 CUST GI.1L1.. PHONE. • • i. 1—� T ' 1 1 1 I 1 CUSTOMER I t;F,i IDOWN G'i OTHERS 11NF All ;'/ • • LINE .AP I• LINE PO LI1IC DR LINE BPI RJ.d PX ;s rON�.FI DOWN I y+l/ ()RANGE BLOCK Fir +'fHI-RS G'L ERANL NO Tr: ........................ 1 1 II;:1 LINIL A. CJI LII"IL '\. REF IJ FD By I:.II';';TOI1ER PFR I'd FPA. 2. Iv1CAUNT R.17 1: WITI-HN C I'•JE ro(.,T (lF T I IF F NL AL1:' IM P'f\NLL. -. FROM CO FIRE ALARM 7'E 'PHONE Lill' UT DETAIL SCALES NO SCALE E.C. TO TURN SWITCH TO 15/75cd. - E.C. TO SET JUMPERS TO PC1-ON, i/-- PC2-OFF, AND PC3-OFF. BBB°o F Ilmlm LC. TO TURN SWITCH TO 15/75cd. NOTE: E.C. TO SET JUMPERS, SWITCH, (Sc PUT SKICKERS ON HORN/STROBE BEFORE INSTALLATION. SEE CUT SHEET OR INSTALLAION MANUAL FOR MORE INSTRUCTIONS. ORN/ST.ROBb1' DET IL SCALE: NONE CO C N 0 Z I Q 000 N o (3) OU E _ L-) I— z = O O N IJ_ E LL O 0 IJJ W >-- I O = D 8 N Urn O UE o r''w=3 oz� LOOS 2cL u 0 cYS 0 z w w cYD ® S—BUILTS REV. NO.: 9/9/21(10 DATE: 4.1 W •• X W W = N U) U) N 0 z Lj c° O O -J U Q \ z U D 0 cii M o ENGR.:BRAD O 0 CHK'D BY:STEVE APPV'D BY: STEVE YOUNG W w ROOF CORP FIRE ALARM REPLACEMENT WA 98168 146TH S TREET T UKWILA, DWG.TITLE DIA GRAMS rzZciD F-4-14.4 w H >-- o. CUSTOMER CUSTOMER: