Loading...
HomeMy WebLinkAboutPP - 295 TUKWILA PKWY - BUFFALO WILD WINGS - PERMITS AND PLANS (2)295 TUKWILA PKWY ASSOCIATED PERMITS 13-F-228 8 SIG1.00 WP 11OC;0 #16 FPLR TO FACP SIG1 #16 FPLR 7 VERIFY DUCT DETECTOR LOCATION WITH INSTALLING CONTRACTOR. REMOTE LED (IF REQUIRED) PROVIDED AND INSTALLED {BY OTHERS. 6 5 0 • 4 LO-_-__ 0 SIG1.005 WOMEN'S C 1575CD i 107 M33.12U F SERVICE (#18 FPLR SLC #16 FPLR TAKE OUT 7103 M33.13 #18 FPLR #18 FPLR VERIFY KITCHEN SUPPRESSION SYSTEM -- -CONNECTION LOCATION WITH INSTALLING CONTRACTOR M33.09 ! (SLC #16 FPLR TO FACP SIG2 #16 FPLR M3308 M33-0 S102.004 C 110CD #16 FPLR +133.05 SIG2.0031 wP,11oco PATIO :1201 1_ ��y❑�Cj1�/'/WI hrrut Comrnents Red Pei The Attached Letter These plans have been i lvi Wed by The Tukwila Fire �jl il(c�n E'((ureai, , ._ , t I,. , , .. -�:ii current City I'1 •,i {I,s ,irds. c.:';;}r.. Ir :. is ; i ' l i. t o I rors and Iciswhichnot e ; o i 3tions of adopted d-... r5 ibiiity for the -'quacy of design 5 tr i,1' Ldp'=1 th designer. t I deletion ,, r. i , , to � f1� s .. drawings after ,, ll7rh�f v l,t tS d pie 1r, ii «C.}lu this , rept i' ^ , 1 s billii require a resubi'nitt3i of revis u drawings ut oque nt approval. Final acceptance is sabect to field test and inspection by The Tukwila Fire Prevention Bti eau. Date: - / 7 By: NOTICE A completed, signed, Tukw114 Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing i'h•tk"vizivt\ okti;(r.1 -k:# 64. elr. ri- T. 4.1- e,,,k,„( » Zhs44t ( 6.-eatw- kaJk 4I4Iy 664 14,44 FA 4v4.4 - 6•ti i^C, T �►�'k.ut..(,�y u-� �. kho e k i Sod TUKWILA FIRE DEPARTMENT Please call 206-5754407 and give this Fire P cr rnit No. 1'3-F-�-� and exact address for shut- down or restoration appr i> I. 0� C 110CD ,o. C 11CC.0 C 157500 SYSTEM INPUTS SYSTEM OUTPUTS Required Fire Safety Control , w r/��`r ..�ro,C '. C . r ra obi b' /4.,:e .S711/°'1.i."0 F/F%F ��,°.-•�'�jl� ��°;gym/2' elve ei / iii 1• '81��0r/4FL A BIC DIE-F1G HI 1 Manual Fire Alarm Boxes 0 Qty. 0101 Standby ( 1 2 Smoke Detectors 0 Panel Equipment 010 Addressable Pull -Station 1 2 3 Waterflow 0 206.0000mA 01 356.0000mA 01 3 4 Kitchen Hood System 0 206.0000mA 0101 I 1 4 5 IN -Duct Smoke Detectors SCR 01 1 10 10 5 6 Sprinkler Control Valve 176.0000mA 352.0000mA PC2R 2 1 6 7 Fire Alarm AC Power Failure 424.0000mA SCR 2\ Strobe, Standard DB, Ceiling Mount, Red (Notification) 1 7 8 Fire Alarm System Low Battery P2RK 10 Horn/Strobe, Standard CD, Red, Outdoor (Notification) 10 1 8 9 Open Circuit 2 1 10 0.0000mA 10 1 9 10 Ground Fault • - 10 0.0000mA 181.0000mA 1 10 11 Notification Appliance Circuit Short • 1 10 0.5500mA 3.8500mA 11 WP 110CD WP 110CD C 1575'::D �ry C 110CD s,o; y C 75CD C 75CD A BICID EFG HI1 WP 110CD H OPERATIONAL MATRIX 5700 ra MM 4. 4 4• 016 FPLR 1 3 2 1 Battery Calculations for Panel: 5700 Part No:5700 - 5700 IntelliKnight® Model 5700 Single Loop Job number: 1 Job name: Drawing2 Part No. Qty. Description Standby Total Standby Alarm Total Alarm 5700 Panel Equipment P2RK PC2R Addressable Pull -Station S0500 -PS 212.0000mA 176.0000mA 5700 main card 1 Main Card 206.0000mA 206.0000mA 356.0000mA 356.0000mA MM 19.7689V (0.1121V) Total Panel Stby 206.0000mA Total Panel Alarm 356.0000mA wP 19.7453V Peripherad Devices PC2R SCR Strobe, Standard DB, Ceiling Mount, Red, 1575CD O (c PC2R 2 Horn/Strobe, Ceiling mount, Standard CD, Red (Notification) 0.0000mA 0.0000mA 176.0000mA 352.0000mA PC2R 2 Horn/Strobe, Ceiling mount, Standard CD, Red (Notification) 0.0000mA 0.0000mA 212.0000mA 424.0000mA SCR 2\ Strobe, Standard DB, Ceiling Mount, Red (Notification) 0.0000mA 0.0000mA 77.0000mA 154.0000mA P2RK 3 Horn/Strobe, Standard CD, Red, Outdoor (Notification) 0.0000mA 0.0000mA 212.0000mA 636.0000mA EOL 2 EOL 4.7K (Notification) 0.0000mA 0.0000mA 0.0000mA 0.0000mA SCR 2 Strobe, Standard DB, Ceiling Mount, Red (Notification) 0.0000mA 0.0000mA 181.0000mA 362.0000mA SD500-PS 7 SD500-PS Addressable Pull -Station (Signaling line) 0.5500mA 3.8500mA 0.5500mA 3.8500mA 1 0.5500mA 0.5500mA 0.5500mA 0.5500mA S0500 -MIM 4 Mini Module (Signaling line) 0.5500mA 2.2000mA 0.2300mA 0.9200mA 1 0.0000mA 0.0000mA 75.0000mA 75.0000mA WFD-Series 1 Water Flow Switch (Initiating) 0.0000mA 0.0000mA 0.0000mA 0.0000mA OSY2 1 Tamper Switch (Initiating) 0.0000mA 0.0000mA 0.0000mA 0.0000mA Total Peripheral Stby 6.6000mA Total Periph Alarm 2008.3200mA Total Standby Amps 212.6000mA Total Alarm Amps 2364.3200mA Standby time: 24 Hrs 5.102Ah Alarm time: 5 Min 0,197Ah Battery requirement: 5.299Ah Compensation Factors - Standby: 1.2 Alarm: 1.2 Requirement with compensation: 6.359Ah Fire Alarm Symbol Legend SYMBOL DESCRIPTION PART NUMBER Appliance Desc Panel Distance Current Fire alarm panel 5700 5700 FACP P2RK PC2R Addressable Pull -Station S0500 -PS 212.0000mA 176.0000mA 20.0124V 19.681V F 002 Monitor Module SD500-MIM Horn/Strobe, Ceiling mount, Standard CD, Red, 110CD 48'-0 MM 19.7689V (0.1121V) Horn/Strobe, Standard CD, Red, Outdoor P2RK Strobe, Standard DB, Ceiling Mount, Red, 1575CD 24'-0 wP 19.7453V Horn/Strobe, Ceiling mount, Standard CD, Red PC2R SCR Strobe, Standard DB, Ceiling Mount, Red, 1575CD O (c 77.0000mA 19.738V (0.0074V) -01 EOL Strobe, Standard DB, Ceiling Mount, Red SCR 0.0000mA 19.738V ,0 c 19.5404V (0.1062V) KITCHEN HOOD 166'-0 754.0000mA ANSUL KH000 Total Current: 754.0000mA (Total VDrop Percent:2.29%) Total Voltage Drop : 0.462V Fs Water Flow Switch 006 SCR Strobe, Standard D3, Ceiling Mount, Red, 110CD Ts Tamper Switch 181.0000mA 19.3764V (0.0231V) W EOL 4.7K EOL 2'-0 0- Duct Detector (OV) Smoke Detector SD500-APS 1174.0000mA 4, KHOOD 12VDC 7Ah BACK-UP BATTERIES TO BE USED Circuit Calculations Panel: 5700 Card: 00 Circuit:SIG1 CircuitName: SIG1 Circuit Type: Notification/24V DC Terminal Voltage: 20.2V:DC Amperage: 1.2500A Cable: Power, Limited, Multiple Conductor#14 Calculations based on Running Total Length. Design Criteria: Ambient temperature: 167°F Max. operating voltage drop: 10% Job number: 1 Job name: Drawing2 Device Part No Appliance Desc Panel Distance Current Voltage 20.2V Voltage Drop 5700 001 P2RK PC2R Horn/Strobe, Standerd CD, Red, Outdoor, 110CD Horn/Strobe, Ceiling; mount, Standard CD, Red, 75CD 39'-0 36-0 212.0000mA 176.0000mA 20.0124V 19.681V (0.1876V) (0.1314V) 002 003 PC2R Horn/Strobe, Ceiling mount, Standard CD, Red, 110CD 48'-0 212.0000mA 19.7689V (0.1121V) 00.4 SCR Strobe, Standard DB, Ceiling Mount, Red, 1575CD 24'-0 77.0000mA 19.7453V (0.0236V) 005 SCR Strobe, Standard DB, Ceiling Mount, Red, 1575CD 15'-0 77.0000mA 19.738V (0.0074V) -01 EOL EOL 4.7K 2'-0 0.0000mA 19.738V (0V) 19.5404V (0.1062V) 005 166'-0 754.0000mA 61'-0 Total Current: 754.0000mA (Total VDrop Percent:2.29%) Total Voltage Drop : 0.462V Circuit Calculations Panel: 5700 Card: 00 Circuit:SIG2 CircuitName: SIG2 Circuit Type: Notification/24V DC Terminal Voltage: 20.2V:DC Amperage: 1.2500A Cable: Power, Limited, Multiple Conductor #14 Calculations based on Running Total Length. Design Criteria: Ambient temperature: 167°F Max. operating voltage drop: 10% Job number: 1 Job name: Drawing2 Device Part No Appliance Desc Distance Current Voltage Voltage Drop 5700 Panel 20.2V 001 PC2R Hom/Strobe, Ceiling mount, Standard CD, Red, 75CD 18'-0 176.0000mA 20.0652V (0.1348V) 002 P2RK Hom/Strobe, Standard CD, Red, Outdoor, 110CD 24'-0 212.0000mA 19.9124V (0.1528V) 003 P2RK Horn/Strobe, Standard CD, Red, Outdoor, 11000 53'-0 212,0000mA 19.6466V (0.2658V) 004 PC2R Horn/Strobe, Ceiling mount, Standard CD, Red, 110CD 29'-0 212.0000mA 19.5404V (0.1062V) 005 SCR Strobe, Standard DB, Ceiling Mount, Red, 110CD 61'-0 181.0000mA 19.3995V (0.1409V) 006 SCR Strobe, Standard D3, Ceiling Mount, Red, 110CD 20'-0 181.0000mA 19.3764V (0.0231V) -01 EOL EOL 4.7K 2'-0 0.0000mA 19.3764V (OV) 207-0 1174.0000mA Total Current:1174.0000mA (Total VDrop Percent:4.08%) Total Voltage Drop : 0.8236V DRAWN BY: ROBERT VAUGHN L & I #VAUGHR*981Q4 SEATTLE FIRE DEPT. #SCPV-04243 NICET III #115522 CITY OF REDMOND-DESIGNER OF RECORD #10-B-113 PROPERTY OF AND ALL RIGHTS RESERVED FIRE PROTECTION INC DATE: 9/13/2013 11. FIRE PROTECTION INC. 1730 Gibson Road Everett, WA. 98204 425-29D-9600 FIRE ALARM BUFFALO WILD WINGS 225 TUKWILA PARKWAY TUKWILA, WA. FIREPIk021 ML SIZE FSCM NO. DWG NO. FA 1.0 REV 2 SCALE 1/8" = 1' 0" SHEET 8 6 5 4 3 1 D C 295 TUKWILA PKWY -13-F-228 ID t SEP 2 5 2013 TUKWILA FIRE .32?7*7 t'233 .fir S 7 6 2 16 FPLR SIG1.001 WP 110CD Oo24 CRAWL SPACE / ACCESS CRAWL SPACE A. 18 FPLR MECH OTC M33.12�F. 4 SERVICE a *18 FPLR TO FACP SIG1 #16 FPLR ORDERING LTJ #18 FPLR lOW M33.07 TAKEOUT i1 PICK-UP AUDIO SHUTDOWN RELAY TO FACP SIG2 #16 FPLR ENTR t LOC KHOOD M33.00 BEER 1113] M3 M33.05 FREEZE 118 • 016 FPLR 1 Fire -Alarm Symbol Legend SYMBOL FACP ESCRIPTION Addressable Pull -Station Module Horn/Strobe, Standard CD, Red, Outdoor PART NUMBER P2RK Horn/Strobe, Ceiling mount, Standard CD, Red PC2R Strobe, Standard DB, Ceiling Mount, Red SCR ilNSUL KHOOD KITCHEN HOOD FS Water Flow Switch Tamper Switch' EOL 4.7K ANN Remote Annunciator EOL 5860R Addressable Heat Detector SMOG -ANS DRAWN BY: ROBERT VAUGHN L & I #VAUGHR*981Q4 SEATTLE FIRE DEPT. #SCPV-04243 NICET III #115522 CITY OF REDMOND-DESIGNER OF RECORD #10-B-113 PROPERTY OF AND ALL RIGHTS RESERVED FIRE PROTECTION INC DATE: 1/23/2014 B FIRE ALARM -AS BUILTS FIRE:, PROTECTION INC. 1730 Gibson Road Everett, WA. 98204 425-290-9600 FIREPI*021 ML SIZE D FSCM NO. BUFFALO WILD WINGS 225 TUKWILA PARKWAY 2 f( TUKWILA, WA. DWG NO. FA 2.0 REV 1 SCALE 118" =1' 0" SHEET 3 1