Loading...
HomeMy WebLinkAboutPP - 319 TUKWILA PKWY - UNKNOWN - PERMITS AND PLANS319 TUKWILA PKWY ASSOCIATED PERMITS 17-F-180 1 307 TUKWILA PARKWAY SUITE 319 —FIJI<0 3 a N b. '` a gnua 1 88 INPUTS AND ACTIONS Fire Alarm Symbol Legend PART NUMBER DEVICE MOUNTING DETAIL SYMBOL DESCRIPTION FACP E INTELLIKNIGHT, FACP, 6-FLEXPUT, I/O CIRCUITS, 1-4 LOOP ' 5820 XL /•/, ROOF DECK // l , / / LNAc _ E 6 AMP NAC POWER SUPPLY W/SYNCH 04/_ MOUNT TO 1 n PULL STATION, SINGLE ACTION, ADDRESSABLE SK -PULL -SA 1 s›:rxo STROBE, 2 WIRE, M -C, WHITE, WALL SW 3 pi.„,,, HORN/STROBE, 2 WIRE, M -C, WHITE, CEILING PC2W STRUCTURE / BASE \ HEAD J -BOX ABOVE CEILING DEVICE SUPPORT BRACKET `' •Ea4M re EOL 4.7K EOL -4.7 2 / 18/2 FPLR, 14/2 FPLR 6 AMP NAC POWER SUPPLY W/SYNCH SILENT KNIGHT 5495 5495 1 5495 POWER EXTENDER PANEL MAIN MOTHERBOARD SILENT KNIGHT 5495 5495B �\-- PLASTER RING j SEND TROUBLE SIGNAL TO C.S. MONITORING CEILING STROBE, 2 WIRE, M -C, WHITE, WALL SYSTEM SENSOR BASEaaw .— HEAD SMOKE OR HEAT DETECTOR SW 3 HORN/STROBE SYSTEM SENSOR PC2W PC2W 1 PULL STATION, SINGLE ACTION, ADDRESSABLE SILENT KNIGHT PULL -SA SK -PULL -SA 2 EOL 4.7K SILENT KNIGHT EOL -4.7 EOL -4.7 SEND WATERFLOW SIGNAL TO C.S. MONITORING ILLUMINATE LED ON DETECTOR MANUAL PULL STATION BACK MOUNTED WALL BOX TO FRAMING LIFT / FIRE ALARM O 80" �� 48" L-, r r INPUTS AND ACTIONS Fire Alarm Symbol Legend PART NUMBER QUANTITY SYMBOL DESCRIPTION FACP E INTELLIKNIGHT, FACP, 6-FLEXPUT, I/O CIRCUITS, 1-4 LOOP ' 5820 XL 1 LNAc _ E 6 AMP NAC POWER SUPPLY W/SYNCH 5495 1 n PULL STATION, SINGLE ACTION, ADDRESSABLE SK -PULL -SA 1 s›:rxo STROBE, 2 WIRE, M -C, WHITE, WALL SW 3 pi.„,,, HORN/STROBE, 2 WIRE, M -C, WHITE, CEILING PC2W 3 `' •Ea4M re EOL 4.7K EOL -4.7 2 FIRE ALARM CABLING LEGEND CODE CABLE LINETYPE CIRCUIT TYPE MANUFACTURER PART NO. CABLE TYPE A - INITIATING DEVICE CIRCUIT BELDEN 5320UL 18/2 FPLR B 5820 XL NOTIFICATION APPLIANCE CIRCUIT BELDEN 5120UL 1412 FPLR C AUXILIARY DEVICE CIRCUIT BELDEN 5120UL 14/2 FPLR D Panel: FAPS1 REMOTE ANNUNCIATOR CIRCUIT BELDEN 5320UL, 5120UL 18/2 FPLR, 14/2 FPLR 6 AMP NAC POWER SUPPLY W/SYNCH Bill of Material Qty 1 Description Manufacturer Model Part No. Panel: FACP FA2.1 SYSTEM RISER DIAGRAM & BATTERY CALCULATIONS 1 INTELLIKNIGHT, FACP, 6-FLEXPUT, I/O CIRCUrTS, 1-4 LOOP SILENT KNIGHT 5820 5820 XL 1 MAIN MOTHER BOARD SILENT KNIGHT 5820 5820 XLB INDICATE DEVICE AT FACP 1 Panel: FAPS1 1 6 AMP NAC POWER SUPPLY W/SYNCH SILENT KNIGHT 5495 5495 1 5495 POWER EXTENDER PANEL MAIN MOTHERBOARD SILENT KNIGHT 5495 5495B SEND TROUBLE SIGNAL TO C.S. MONITORING 3 STROBE, 2 WIRE, M -C, WHITE, WALL SYSTEM SENSOR SW SW 3 HORN/STROBE, 2 WIRE, M -C, WHITE, CEILING SYSTEM SENSOR PC2W PC2W 1 PULL STATION, SINGLE ACTION, ADDRESSABLE SILENT KNIGHT PULL -SA SK -PULL -SA 2 EOL 4.7K SILENT KNIGHT EOL -4.7 EOL -4.7 VICINITY MAP DRAWINGINDEX SHEET NO. SHEET DESCRIPTION FA0.1 TITLE SHEET FA1.1 FLOOR PLAN - FIRE ALARM SYSTEM FA2.1 SYSTEM RISER DIAGRAM & BATTERY CALCULATIONS O Without Comments As Noted in Red O Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City -tandards. Acceptance is subject to errors and omissions which do not authorize violations of adopted c:`andards and ordinances. The responsibility for the dequacy of design rests totally with the designer. =editions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 9, — a (e I )By: �i ____•----_ OUTPUTS AND CONTROLS OPERATE ALL AREA EVACUATION SIGNALS SOUND LOCAL PIEZO AT FACP INDICATE DEVICE AT FACP SEND ALARM SIGNAL TO C.S. MONITORING SEND TROUBLE SIGNAL TO C.S. MONITORING SEND SUPERVISORY SIGNAL TO C.S. MONITORING SEND WATERFLOW SIGNAL TO C.S. MONITORING ILLUMINATE LED ON DETECTOR TUKWILA PIM 7.7.PARTMENT Please call 206-575.4407 and give this Fire Permit No. L -E- I2 0 and exact address for shut- down or restoration approval. REVISIONS ENGINEER'S STAMP OF APPROVAL NO. DESCRIPTION DATE BY ADRIAN M. STEIK Senior E gkwering Technician, level 1 NICET Cerbf.aton Number. 093706 0 Authorizing Signature. %,r„�- H.. �"9 FE f1 C1 G;af7 ICE$ .•® 0 0 0•• ••® 0 0 00• • • ®000 • • .•000 O•• ICOS•Co Fire Protection FIRE PROTECTION AND LIFE SAFETY SPECIALISTS WASHINGTON OFFICE 4308 South 131st Place Tukwila, Washington 98168 call (206) 438-3355 • fax (206) 438-3356 SAN DIEGO • LOS ANGELES • FRESNO • SAN FRANCISCO • SACRAMENTO • PORTLAND • SEATTLE 1800 Bickford Ave. Snohomish, WA 98290 call (800) 742-8960 • fax (509) 466-2937 www.safeconsulting.biz l contact©safeconsulting.biz www.coscofire.com PROJECT: BOBA LUST TEA HOUSE T.I. - j 3errUKWILA PARKWAY SUITE 319 sA TUKWILA, WA 98188 DATE : 9/11/17 DRAWN BY : JJP CONTRACT WITH: License No: COSCOFP935MS CONTRACTOR NAME STREET NO. CITY DRAWING TITLE TITLE SHEET JOB NO. 319 TUKWILA PKWY 17-F-180 OFFICEISTORAGE RESTROOM BACK OF KITCHEN 1 15CD NAC2.001 HR TO FAPS1 ; fAC2.002 110CD NAC2 EOL 4.7K KITCHEN/SERVICE DINING AREA SLC2•M:001 FLOOR PLAN - FIRE ALARM SYSTEM SCALE= 1/4"=1'0" REVISIONS ENGINEER'S STAMP OF APPROVAL NO. DESCRIPTION DATE BY ADRIAN M. STEIK FE HVITES 1800 Bickford Ave. Snohomish, WA 98290 call (800) 742-8960 • fax (509) 466-2937 www.safeconsulfing.biz I contact@safeconsulting.biz .•® 0 0 o.. - 00000• • ' 000000' **le 00 ®e cosco Fire Protection FIRE PROTECTION AND LIFE SAFETY SPECIALISTS WASHINGTON OFFICE 4308 South 131st Place Tukwila, Washington 98168 call (206) 438-3355 • fax (206) 438-3356 SAN DIEGO • LOS ANGELES • FRESNO • SAN FRANCISCO • SACRAMENTO • PORTLAND • SEATTLE www.coscofire.com License No: COSCOFP935MS PROJECT: BOBA LUST TEA HOUSE T.I. (�.397-TUKWILA PARKWAY SUITE 319 TUKWILA, WA 98188 /?- -/S'� DATE : 9/11/17 SCALE : 1/4"=1'0" DRAWN BY : JJP CONTRACT WITH: CONTRACTOR NAME STREET NO. CITY JOB NO. 1 7-169 DRAWING TITLE FLOOR PLAN - FIRE ALARM SYSTEM EOL 4.7K L..: E 110CD E EOL 4.7K NAC2 110CD NAC2•002 110CD E SYSTEM RISER DIAGRAM V-1} SCALE = NOT TO SCALE 15CD NAC2.001 15CD 15CD /E• ADDED DEVICES EXISTING FAPS1 r EXISTING FACP L LOCATED IN FACP ROOM �.F. SLC2•M:001 Battery Calculations for Panel: FAPS1 Part No:5495 - 6 AMP NAC POWER SUPPLY W/SYNCH • Job number: 17-169 Part No.,Qty. Part No Description Panel Equipment Standby Total Standby Alarm Total Alarm 5495 5495B 1 5495 POWER EXTENDER PANEL MAIN MOTHER BOARD 0.075A 0.075A 0.215A 0.215A STROBE, 2 WIRE, M -C, WHITE, WALL, 15CD 11'-10 0.066A Total Panel Stby 0.075A Total Panel Alarm 0.215A STROBE, 2 WIRE, M -C, WHITE, WALL, 15CD 2'-9 5'-0 Peripheral Devices 20.348V 20.335V (0.009V) (0.014V) 003 PC2W SW 3 STROBE, 2 WIRE, M -C, WHITE, WALL (Notification) 0.000A 0.000A 0.066A 0.198A PC2W 3 HORN/STROBE, 2 WIRE, M -C, WHITE, CEILING (Notification) 0.000A 0.000A 0.221A 0.663A EOL -4.7 2 EOL 4.7K (Notification) 0.000A 0.000A 0.000A 0.000A Total Current: 0.574A (Total VDrop Percent:0.34%) Total Voltage Drop : 0.069V Total Peripheral Stby 0.000A Total Periph Alarm 0.861A Total Standby Amps 0.075A Total Alarm Amps 1.076A Standby time: 24 Hrs Alarm time: 5 Min Battery requirement: Compensation Factors - Standby: 1.2 Alarm: 1.2 Requirement with compensation: 1.8Ah 0.09Ah 1.89Ah 2.268Ah Circuit Calculations Panel: FAPS1 Card: 01 Circuit:NAC1 CircuitName: NAC1 Circuit Type: Notification Terminal Voltage: 20.4V:DC Amperage: 2.000A Cable: 14/2 SOL JKT FPLR 1M RL RED #14 Calculations based on Running Total Length. Design Criteria: Ambient temperature: 167°F Minimum operating voltage: 16V Device Part No A. •fiance Desc Distance Current Voltase Volta. a Drop 5495 Panel 20.4V 001 SW STROBE, 2 WIRE, M -C, WHITE, WALL, 15CD 11'-10 0.066A 20.358V (0.042V) 002 SW STROBE, 2 WIRE, M -C, WHITE, WALL, 15CD 2'-9 5'-0 0.066A 0.221A 20.348V 20.335V (0.009V) (0.014V) 003 PC2W HORN/STROBE, 2 WIRE, M -C, WHITE, CEILING, 110CD 004 PC2W HORN/STROBE, 2 WIRE, M -C, WHITE, CEILING, 110CD 3'-4 0.221A 20.331V (0.004V) 004 EOL -4.7 EOL 4.7K 1'-6 0.000A 20.331V (OV) 24'-5 0.574A Total Current: 0.574A (Total VDrop Percent:0.34%) Total Voltage Drop : 0.069V Circuit Calculations Panel: FAPS1 Card: 01 Circuit:NAC2 CircuitName: NAC2 Circuit Type: Notification Terminal Voltage: 20.4V:DC Amperage: 2.000A Cable: 14/2 SOL JKT FPLR 1M RL RED #14 Calculations based on Running Total Length. Design Criteria: Ambient temperature: 167°F Minimum operating voltage: 16V Device Part No Appliance Desc Distance Current Voltage Voltage Drop 5495 Panel 20.4V 001 SW STROBE, 2 WIRE, M -C, WHITE, WALL, 15CD 65'-4 0.066A 20.285V (0.115V) 002 PC2W HORN/STROBE, 2 WIRE, M -C, WHITE, CEILING, 110CD 29'-7 0.221A 20.245V (0.041V) EOL -4.7 EOL 4.7K 1'-6 0.000A 20.245V (OV) 96'-5 0.287A Total Current: 0.287A (Total VDrop Percent:0.76%) Total Voltage Drop : 0.155V SYSTEM BATTERY CALCULATIONS (El SCALE = NOT TO SCALE REVISIONS NO. DESCRIPTION DATE BY ENGINEER'S STAMP OF APPROVAL ADRIAN M. STEIK Senior Engineering Tech -Wan, level, N[OT Certlfra0on Number. 093_7_066c''� Authorizing Signature. (. • H.. 3-V 1800 Bickford Ave. Snohomish, WA 98290 call (800) 742-8960 • fax (509) 466-2937 www.safeconsulting.biz 1 contact@safeconsulting.biz • O 0000•. • ® 0•. *00000' *0000°' COSCO Fire Protection FIRE PROTECTION AND LIFE SAFETY SPECIALISTS WASHINGTON OFFICE 4308 South 131st Place Tukwila, Washington 98168 call (206) 438-3355 • fax (206) 438-3356 SAN DIEGO • LOS ANGELES • FRESNO • SAN FRANCISCO • SACRAMENTO • PORTLAND • SEATTLE www.coscofire.com License No: COSCOFP935MS PROJECT: BOBA LUST TEA HOUSE T.I. Ili-307-TUKWILA PARKWAY SUITE 319 TUKWILA, WA 98188 CONTRACT WITH: CONTRACTOR NAME STREET NO. CITY DRAWNG TITLE SYSTEM RISER DIAGRAM & BATTERY CALCULATIONS