HomeMy WebLinkAboutPP - 349 TUKWILA PKWY - UNKNOWN - PERMITS AND PLANS349 TUKWILA PKWY ASSOCIATED PERMITS 12-5-133 71-5-097 04-5-225 11-S-150 11-5-002 JUN -26-2012 13:1A PATRIOT FIRE ATRIOT FIRE PROTECTION Fire Sprinklers Save Lives! 253 284 3547 P.02 2707 70TH Avenue East Tacoma, WA 98424 June 26, 2012 To: Al Metzler Tukwila Fire Department 444 Andover Park E Tukwila, WA Re: I Fly 349 Tukwila Parkway Tukwila, WA 98188 Mr. Metzler: FELE TEL: (253) 926.2290 FAX: (253) 922.6150 Patriot Fire Protection, Inc. is requesting a shut down number so we can shut down the sprinkler system at the above project location to Change out an old existing 8" Grinnell Model A alarm valve with a new Reliable model E valve and trim. Please feel free to call with any questions. Sincerely, PATRIOT FIRE PROTECTION, INC. John Dacca Project Manager Phone: 253-284-3467 Fax: 253-922-6150 VANCOUVER, WA OFFICE TEL (360) 699.4403 PORTLAND (503) 222.6001 FAX (360) 699.4485 TUKWILA FIRE DEPARTMENT Please rail 206-575-4407 and give this Fire Permit No. 1a -5-133 and exact addres3 for shut- down hutdown or restoration approval. www.patrlotfire.com PATRIFP099CF SPOKANE, WA OFFICE TEL (509) 926.3428 FAX (509) 926.3708 TOTAL P.02 JAN -04-2011 11:34 PATRIOT FIRE, FIFE ATIR FIRE PROTECTION, INC. January 4, 2011 253 922 6150 P.01/01 flre Mders Save Lives! 707H Avenue..East • Swi:i^;`,, T .WA98 $' .. 928:229°: fIIX �259)oe2,e150 To: Lt. Al Metzler Tukwila Fire Department 444 Andover Park E Tukwila, WA Re: I -Fly (Future. Tenant) The Annex ;@ Southcenter 301 Tukwila Parkway Tukwila, WA Lt. Metzler: ;.�KV1�iLA FIRE DEPAK I LIMUlt Please call: 575.0407, and give this job No. / I - S -ODD—. and exact address for shuts ,tun or restoration aooroval. Patriot Fire Protection, Inc. is requesting a shut down number f the existing fire sprinkler system located at the above address. capping the 4" mainas needed for demolition of the roof structure. An addition and remodel of the building is to begin in February, an }% complete the sprinkler system in June. We are currently working on permit drawings and will have them. we can. Please feel free to call with any questions. Sincerely, PATRIOT FIRE PROTECTION, INC. Evan Boulanger Project Manager NANFORb, WA QrT1GE TEL (509) 373.0096 FAX (509) 373.8919 vANCouvER, WA OFFICE TEL (360) 6984403 PORTLAND (503) 222.6001 FAX (360) 699.4485 PATRIFPO*$CP ernoiition of ifl:consist of • of intends to as soon as • a: TOTAL P.01 Please call: 575-4407 and give this job No. O `-1-5-^ 2 Z5 and exact address for shut- mr NEW 114x1 MECH. 111` NAVY 4' MAIN A approve, MARINES jA TEST NR FORCE RES. 4' MAIN TEST STOR. STORAGE STOR. A.F. TEST ARMY STOR. AIR FORCE AVE BATH BATH ELEC. I 146" = la -On FILE ACCEPTED Without Comments ❑ As Noted In Red 0 Per The Attached Letter These plans have hien reviewed by The Tukwila Fire Preve.ntion Bureau fcr conformance v‘'ith current city standards. Acceptance suiaj ct to errors and 1omissions hich do not iluthorize violations of adopted standards and orcini3ric s. The responsibility for the aciecnj �;y (_ (. ,. ` i..t r::�'.s tit lly, wit'! the d �' � deomissions v, -ac&lons, r .,iai;,s,l , or r.ion ;� these drawings after i this d,.1.? ,f:;l' ; ,,-i r;l;is a riiaand will require a ' resubrnit al of revised ora .in • gs 'or subsequent approval. • i r. g Final acceptance is subject to field test and inspection by I he Tukwila Fire Prevention Bureau. Date: 1/ /-34(1 By: ' -742 NERAL NOTES 1. ALL MATERIAL AND INSTALLATION PER NFPA 13 2. ALL REQUIRED ACCEPTANCE TESTING SHALL BE PERFORMED BY THE INSTALLER IN ACCORDANCE WITH NFPA13 AND THE AUTHORITY HAVING JURISDICTION. / 2.// 3. AU. NEW PIPING IS AWED SCHED. 40 WITH C.I. FITTINGS. 4. AU. ARMOVERS OVER ^ARE TO BE HUNG PER NFPA 13 5. AU. AREAS ARE EXISTING AND SPRINKLERED EXCEPT TEST ROOM SPRINKLER LEGEND: • A- ADDED GEM Ty -e ;ow KAD QTY- 1 446 0 FIRE PROTECTION SYSTEMS, INC. 23220 MAPLE VAIEEY/BLACK DIAMOND RD. S.E. - MAPLE VALLEY, WA 98038 SUITE 3-0 425-432-4401 CONTTL UC. ACEFIPS147P1 ACE Nnv It SYSTEM DESIGN CRITERIA PER NFPA 13/ORDINARY HAZ. GRP u PROJECT ARMED FORCES RECRUITING CENTER 349 TUKWILA PY TUKWILA, WA CONTRACT int RIVER CITY CONSTRUCTION FEDERAL WAY, WA DRWO. TITLE FIRE SPRINKLER T.L PLANS DATE 11-2-04 REVISED CONMR. II 04-2145 349 TUKWILA PKWY 04-S-225 DRAWN BY MM SCALE AS NOTED APPROVALS BY C1TY OF RENTON 1 OF t 4 istv SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 0223000010 Site Address: 349 Tukwila parkway Suite Number: Floor: Tenant Name: I -Fly Indoor Skydiving New Tenant? ❑ - Yes ❑ - No Property Owner's Name: Sky Entertainment Mailing Address: 14416 150th Ave. SE Renton WA 98059 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Mark Metzger Day Telephone: 253-284-3437 Company Name: Patriot Fire Protection, Inc. Mailing Address: 2707 70th Ave. E. Tacoma WA 98424 markm@patriotfire.com City State Zip E-mail Address. Fax Number: 253-2843438 Valuation of Project (contractor's bid price): $ 6.000 Scope of Work (please provide detailed information): add 21 sprinklers to the mechanical service level PERMIT APPLICATION NOTES Value of Construction -- In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 9R AUTHORIZED AGENT: Signature: !//" Date: 7/1 1/1 1 Print Name: Mark Metzger Day Telephone: 253-284-3437 Plan Permit App.doc 5/14/10 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: I -Fly 349 Tukwila Parkway Permit No.: 11-S-150 Date: July 13, 2011 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend spriinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. PATRIOT FIRE PROTECTION, INC 2707 70th AVENUE EAST TACOMA,WA 98424 HYDRAULIC CALCULATIONS FOR FILE NUMBER: DATE: JUL 11, 2011 -DESIGN DATA - OCCUPANCY CLASSIFICATION: Ordinary Group 1 DENSITY: .15 gpm/sq. ft. AREA OF APPLICATION: 1,950 sq. ft. COVERAGE PER SPRINKLER: 118 sq. ft. NUMBER OF SPRINKLERS CALCULATED: 17 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 336.8 gpm TOTAL WATER REQUIRED (including hose): 586.8 gpm FLOW AND PRESSURE (@ BOR): 337gpm @ 83.3psi SPRINKLER ORIFICE SIZE: 1/2 inch NAME OF CONTRACTOR: Patriot Fire Protection, Inc. DESIGN/LAYOUT BY: Mark Metzger AUTHORITY HAVING JURISDICTION: City of Tukwila CONTRACTOR CERTIFICATION NUMBER: PATRIFP099CF a fele ,4 t L Pay 1(-S.'"1515 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 38081321 ) HRS SYSTEMS, INC. PETERSBURG, TN 37144 PETERSBURG, TN 37144 Items listed in bold print are automatically transfered from the calculation report SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 7/11/2011 T:\SASS\MARKM\I FLY\ROOF.SDF JOB TITLE: I Fly Roof WATER SUPPLY ANALYSIS a trl0 0 0 0 c) 3 O H m a 0 0 0 .O •rl to N -r-1 0) a o 0 0 -r{ 4-1 ro %/ g H N N 0 0 0 M �-i 0 0 0 O — V O N 0 0 0 0 0 0 'Cr • r.i 0 N C' lO CO 0 1 C• •-I M Lf) N 0 FC C7 W W C4 W M m a w 41 — a rn •-1 -- O o CO N 0 u) O 0 FLOW (GPM) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 7/11/2011 T:\HASS\MARKM\I FLY\ROOF.SDF JOB TITLE: I Fly Roof NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 120.0 20.0 13000.0 119.7 586.8 87.6 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 586.8 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 250.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 336.8 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (FT) (PSI) (GPM) 401 64.8 K= 5.60 10.0 17.7 402 64.5 K= 5.60 11.3 18.8 403 64.2 K= 5.60 13.7 20.7 404 62.9 - - - - 22.6 405 64.8 K= 5.60 10.1 17.8 406 64.5 K= 5.60 11.3 18.8 407 64.2 K= 5.60 13.7 20.7 408 62.9 - - - - 22.7 - - - 409 64.4 K= 5.60 10.3 17.9 410 64.2 K= 5.60 11.5 19.0 411 63.9 K= 5.60 14.0 20.9 412 62.5 - - - - 23.0 413 64.4 K= 5.60 10.4 18.1 414 64.2 K= 5.60 11.7 19.2 415 63.9 K= 5.60 14.2 21.1 416 62.3 - - - - 23.4 417 64.4 K= 5.60 10.7 18.3 418 64.2 K= 5.60 12.0 19.4 419 63.9 K= 5.60 14.5 21.3 420 62.3 - - - - 23.9 - - - 421 64.4 - - - - 17.0 422 64.2 K= 5.60 17.1 23.1 423 63.9 K= 5.60 18.2 23.9 424 62.3 - - - - 24.7 425 64.4 24.8 426 64.2 24.9 427 63.9 25.0 428 62.2 25.8 429 62.2 28.4 430 29.7 56.6 431 27.2 63.3 6 14.5 73.8 5 14.5 75.1 4 14.5 76.8 3 14.5 77.1 2 14.5 77.2 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 7/11/2011 T:\HASS\MARKM\I FLY\ROOF.SDF JOB TITLE: I Fly Roof NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (FT) (PSI) (GPM) 1 0.5 83.3 DC1 0.0 83.6 DC2 0.0 - - - - 87.6 SOURCE 0.0 SOURCE 87.6 336.8 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 7/11/2011 T:\HASS\MARKM\I FLY\ROOF.SDF JOB TITLE: I Fly Roof NFPA PIPE DATA Pipe Tag K-fac Add F1 Add F1 To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) Notes To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 1 5.60 17.7 Disch 11.00 120 1.3 402 64.5 11.3 0.0 1.000 0.00 -0.1 401 64.8 10.0 17.7 1.049 11.00 0.104 1.1 Pipe: 2 5.60 18.8 Disch 11.00 120 2.4 403 64.2 13.7 17.7 401 1.250 0.00 -0.1 402 64.5 11.3 36.6 1.200 11.00 0.206 2.3 Pipe: 3 5.60 20.7 Disch 4.29 120 9.0 404 62.9 22.6 36.6 402 1.250 E: 3.9 13.48 -0.6 403 64.2 13.7 57.3 1.200 T: 9.6 17.77 0.473 8.4 Pipe: 4 5.60 17.8 Disch 11.00 120 1.3 406 64.5 11.3 0.0 1.000 0.00 -0.1 405 64.8 10.1 17.8 1.049 11.00 0.104 1.1 Pipe: 5 5.60 18.8 Disch 11.00 120 2.4 407 64.2 13.7 17.8 405 1.250 0.00 -0.1 406 64.5 11.3 36.6 1.200 11.00 0.207 2.3 Pipe: 6 5.60 20.7 Disch 4.29 120 9.0 408 62.9 22.7 36.6 406 1.250 E: 3.9 13.48 -0.6 407 64.2 13.7 57.3 1.200 T: 9.6 17.77 0.474 8.4 Pipe: 7 5.60 17.9 Disch 11.00 120 1.3 410 64.2 11.5 0.0 1.000 0.00 -0.1 409 64.4 10.3 17.9 1.049 11.00 0.106 1.2 Pipe: 8 5.60 19.0 Disch 11.00 120 2.4 411 63.9 14.0 17.9 409 1.250 0.00 -0.1 410 64.2 11.5 37.0 1.200 11.00 0.211 2.3 Pipe: 9 5.60 20.9 Disch 3.96 120 9.0 412 62.5 23.0 37.0 410 1.250 E: 3.9 13.48 -0.6 411 63.9 14.0 57.9 1.200 T: 9.6 17.44 0.483 8.4 Pipe: 10 5.60 18.1 Disch 11.00 120 1.3 414 64.2 11.7 0.0 1.000 0.00 -0.1 413 64.4 10.4 18.1 1.049 11.00 0.108 1.2 Pipe: 11 5.60 19.2 Disch 11.00 120 2.5 415 63.9 14.2 18.1 413 1.250 0.00 -0.1 414 64.2 11.7 37.2 1.200 11.00 0.213 2.3 Pipe: 12 5.60 21.1 Disch 3.96 120 9.2 416 62.3 23.4 37.2 414 1.250 E: 3.9 13.48 -0.7 415 63.9 14.2 58.3 1.200 T: 9.6 17.44 0.489 8.5 Pipe: 13 5.60 18.3 Disch 11.00 120 1.3 418 64.2 12.0 0.0 1.000 0.00 -0.1 417 64.4 10.7 18.3 1.049 11.00 0.110 1.2 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 7/11/2011 T:\HASS\MARKM\I FLY\ROOF.SDF JOB TITLE: I Fly Roof Pipe Tag K-fac Add F1 Add F1 To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) Notes To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 14 5.60 19.4 Disch 11.00 120 2.5 419 63.9 14.5 18.3 417 1.250 0.00 -0.1 418 64.2 12.0 37.7 1.200 11.00 0.218 2.4 Pipe: 15 5.60 21.3 Disch 3.96 120 9.4 420 62.3 23.9 37.7 418 1.250 E: 3.9 13.48 -0.7 419 63.9 14.5 59.0 1.200 T: 9.6 17.44 0.500 8.7 Pipe: 16 0.0 0.0 11.00 120 0.1 422 64.2 17.1 0.0 1.000 0.00 -0.1 421 64.4 17.0 0.0 1.049 11.00 0.000 0.0 Pipe: 17 5.60 23.1 Disch 11.00 120 1.1 423 63.9 18.2 0.0 421 1.250 0.00 -0.1 422 64.2 17.1 23.1 1.200 11.00 0.089 1.0 5.60 23.9 Disch Pipe: 18 0.0 4.29 120 6.5 424 62.3 24.7 23.1 422 1.250 E: 3.9 13.48 -0.7 423 63.9 18.2 47.0 1.200 T: 9.6 17.77 0.328 5.8 Pipe: 19 0.0 0.0 11.00 120 0.1 425 64.4 24.8 0.0 1.000 0.00 0.1 426 64.2 24.9 0.0 1.049 11.00 0.000 0.0 Pipe: 20 0.0 0.0 11.00 120 0.1 426 64.2 24.9 0.0 1.250 0.00 0.1 427 63.9 25.0 0.0 1.200 11.00 0.000 0.0 Pipe: 21 0.0 0.0 4.29 120 0.7 428 62.2 25.8 0.0 1.250 E: 3.9 13.48 -0.7 427 63.9 25.0 0.0 1.200 T: 9.6 17.77 0.000 0.0 Pipe: 22 0.0 0.0 10.75 120 0.0 408 62.9 22.7 57.3 403 B3.000 0.00 0.0 404 62.9 22.6 57.3 3.260 10.75 0.004 0.0 Pipe: 23 0.0 57.3 404 10.75 120 0.3 412 62.5 23.0 57.3 407 B3.000 0.00 -0.2 408 62.9 22.7 114.6 3.260 10.75 0.013 0.1 Pipe: 24 0.0 114.6 408 10.75 120 0.4 416 62.3 23.4 57.9 411 B3.000 0.00 -0.1 412 62.5 23.0 172.5 3.260 10.75 0.028 0.3 Pipe: 25 0.0 172.5 412 10.75 120 0.5 420 62.3 23.9 58.3 415 B3.000 0.00 0.0 416 62.3 23.4 230.8 3.260 10.75 0.048 0.5 Pipe: 26 0.0 230.8 416 10.75 120 0.8 424 62.3 24.7 59.0 419 B3.000 0.00 0.0 420 62.3 23.9 289.8 3.260 10.75 0.073 0.8 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 7/11/2011 T:\HASS\MARKM\I FLY\ROOF.SDF JOB TITLE: I Fly Roof Pipe Tag K-fac Add Fl Add F1 To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) Notes To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 27 0.0 289.8 420 10.75 120 1.1 428 62.2 25.8 47.0 423 B3.000 0.00 0.0 424 62.3 24.7 336.8 3.260 10.75 0.097 1.0 Pipe: 28 0.0 336.8 424 429 62.2 28.4 0.0 427 428 62.2 25.8 336.8 B3.000 2E:20.0 3.260 7.50 120 20.00 27.50 0.097 2.7 0.0 2.7 Pipe: 29 0.0 0.0 75.83 120 28.2 430 29.7 56.6 336.8 428 B3.000 7E:70.0 70.00 -14.1 429 62.2 28.4 336.8 3.260 145.83 0.097 14.1 Pipe: 30 431 430 27.2 29.7 0.0 63.3 56.6 0.0 336.8 429 336.8 2E:20.0 4.50 120 6.7 B3.000 T:20.0 54.00 -1.0 3.260 B:14.0 58.50 0.097 5.6 Pipe: 31 0.0 0.0 97.33 120 10.5 6 14.5 73.8 336.8 430 B4.000 5E:65.0 91.00 -5.5 431 27.2 63.3 336.8 4.260 T:26.0 188.33 0.026 4.9 Pipe: 32 5 6 Pipe: 33 4 5 14.5 14.5 0.0 75.1 73.8 0.0 336.8 431 336.8 0.0 0.0 14.5 76.8 336.8 6 14.5 75.1 336.8 Pipe: 34 0.0 0.0 3 14.5 77.1 336.8 5 4 14.5 76.8 336.8 Pipe: 35 2 3 Pipe: 36 1 2 Pipe: 37 DC1 1 Pipe: 38 DC2 DC1 Pipe: 39 SOURCE DC2 0.0 0.0 14.5 77.2 336.8 4 14.5 77.1 336.8 0.5 14.5 0.0 0.5 0.0 0.0 0.0 0.0 0.0 83.3 77.2 0.0 83.6 83.3 87.6 83.6 Source 87.6 87.6 0.0 336.8 3 336.8 0.0 336.8 2 336.8 0.0 336.8 1 336.8 0.0 336.8 DC1 336.8 B4.000 3E:39.0 4.260 B4.000 4.260 B6.000 T:38.0 6.357 11.00 120 39.00 50.00 0.026 66.75 120 0.00 66.75 0.026 24.67 120 38.00 62.67 0.004 50.10 120 B8.000 E:21.0 62.00 8.249 T:41.0 112.10 0.001 B8.000 G: 5.0 8.249 14.00 120 5.00 19.00 0.001 1.3 0.0 1.3 1.8 0.0 1.8 0.2 0.0 0.2 0.1 0.0 0.1 6.1 -6.1 0.0 50.00 140 0.3 D8.000 E:31.0 38.00 -0.2 8.390 G: 7.0 88.00 0.001 0.1 Fixed Pressure Loss Device 4.0 psi, 336.8 gpm 28.00 140 0.1 D8.000 T:59.0 66.00 0.0 8.390 G: 7.0 94.00 0.001 0.1 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 DATE: 7/11/2011 T:\HASS\MARKM\I FLY\ROOF.SDF JOB TITLE: I Fly Roof NOTES (HASS): (1) Calculations were performed by the HASS 8.1 computer program under license no. 38081321 granted by HRS Systems, Inc. 208 South Public Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.003 gpm and a maximum imbalance at any node of 0.111 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 16.7 ft/sec at pipe 15. PATRIOT FIRE PROTECTION, INC 2707 70th AVENUE EAST TACOMA,WA 98424 HYDRAULIC CALCULATIONS FOR FILE NUMBER: DATE: JUL 11, 2011 -DESIGN DATA - OCCUPANCY CLASSIFICATION: Ordinary Group 1 DENSITY: .15 gpm/sq. ft. AREA OF APPLICATION: 1,950 sq. ft. COVERAGE PER SPRINKLER: 118 sq. ft. NUMBER OF SPRINKLERS CALCULATED: 17 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 336.8 gpm TOTAL WATER REQUIRED (including hose): 586.8 gpm FLOW AND PRESSURE (@ BOR): 337gpm @ 83.3psi SPRINKLER ORIFICE SIZE: 1/2 inch NAME OF CONTRACTOR: Patriot Fire Protection, Inc. DESIGN/LAYOUT BY: Mark Metzger AUTHORITY HAVING JURISDICTION: City of Tukwila CONTRACTOR CERTIFICATION NUMBER: PATRIFP099CF CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 38081321 ) HRS SYSTEMS, INC. PETERSBURG, TN 37144 PETERSBURG, TN 37144 Items listed in bold print are automatically transfered from the calculation report DATE: 7/11/2011 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 T:\HASS\MARKM\I FLY\ROOF.SDF JOB TITLE: I Fly Roof pi CT a a a W)ao ▪ 0) tO co of coo OCH G 1w-1 a co in a Q. �n �cno Q. m 0 N ro co N LL 0 m r-1 to ••i M o >, r1 • p to u) ro cm )7' • a' .-I a ao en r-1 N O 0 0 M r-1 0 O — O CD 4OL.Dw awwm(npa4w --a ) -l-- O CO N O O O 0 0 r1 0 O •x •--I a 0 0 CO N O 0 O a w SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 7/11/2011 T:\HASS\MARKM\I FLY\ROOF.SDF JOB TITLE: I Fly Roof NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 120.0 20.0 13000.0 119.7 586.8 87.6 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 586.8 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 250.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 336.8 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (FT) (PSI) (GPM) 401 64.8 K= 5.60 10.0 17.7 402 64.5 K= 5.60 11.3 18.8 403 64.2 K= 5.60 13.7 20.7 404 62.9 - - - - 22.6 405 64.8 K= 5.60 10.1 17.8 406 64.5 K= 5.60 11.3 18.8 407 64.2 K= 5.60 13.7 20.7 408 62.9 - - - - 22.7 409 64.4 K= 5.60 10.3 17.9 410 64.2 K= 5.60 11.5 19.0 411 63.9 K= 5.60 14.0 20.9 412 62.5 - - - - 23.0 413 64.4 K= 5.60 10.4 18.1 414 64.2 K= 5.60 11.7 19.2 415 63.9 K= 5.60 14.2 21.1 416 62.3 - - - - 23.4 - - - 417 64.4 K= 5.60 10.7 18.3 418 64.2 K= 5.60 12.0 19.4 419 63.9 K= 5.60 14.5 21.3 420 62.3 - - - - 23.9 421 64.4 - - - - 17.0 422 64.2 K= 5.60 17.1 23.1 423 63.9 K= 5.60 18.2 23.9 424 62.3 - - - - 24.7 425 64.4 24.8 426 64.2 24.9 427 63.9 25.0 428 62.2 25.8 429 62.2 28.4 430 29.7 56.6 431 27.2 63.3 6 14.5 73.8 5 14.5 75.1 4 14.5 76.8 3 14.5 77.1 2 14.5 77.2 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 7/11/2011 T:\HASS\MARKM\I FLY\ROOF.SDF JOB TITLE: I Fly Roof NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (FT) (PSI) (GPM) 1 0.5 83.3 DC1 0.0 83.6 DC2 0.0 - - - - 87.6 SOURCE 0.0 SOURCE 87.6 336.8 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 7/11/2011 T:\HASS\MARKM\I FLY\ROOF.SDF JOB TITLE: I Fly Roof NFPA PIPE DATA Pipe Tag K-fac Add F1 Add F1 To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) Notes To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 1 5.60 402 64.5 11.3 401 64.8 10.0 Pipe: 2 5.60 403 64.2 13.7 402 64.5 11.3 Pipe: 3 5.60 404 62.9 22.6 403 64.2 13.7 Pipe: 4 5.60 406 64.5 11.3 405 64.8 10.1 Pipe: 5 5.60 407 64.2 13.7 406 64.5 11.3 Pipe: 6 5.60 408 62.9 22.7 407 64.2 13.7 Pipe: 7 5.60 410 64.2 11.5 409 64.4 10.3 Pipe: 8 5.60 411 63.9 14.0 410 64.2 11.5 Pipe: 9 5.60 412 62.5 23.0 411 63.9 14.0 Pipe: 10 5.60 414 64.2 11.7 413 64.4 10.4 Pipe: 11 5.60 415 63.9 14.2 414 64.2 11.7 Pipe: 12 5.60 416 62.3 23.4 415 63.9 14.2 Pipe: 13 5.60 418 64.2 12.0 417 64.4 10.7 17.7 Disch 0.0 17.7 18.8 Disch 17.7 401 36.6 20.7 Disch 36.6 402 57.3 17.8 Disch 0.0 17.8 18.8 Disch 17.8 405 36.6 20.7 Disch 36.6 406 57.3 17.9 Disch 0.0 17.9 19.0 Disch 17.9 409 37.0 20.9 Disch 37.0 410 57.9 18.1 Disch 0.0 18.1 19.2 Disch 18.1 413 37.2 21.1 Disch 37.2 414 58.3 18.3 Disch 0.0 18.3 11.00 120 1.3 1.000 0.00 -0.1 1.049 11.00 0.104 1.1 11.00 120 2.4 1.250 0.00 -0.1 1.200 11.00 0.206 2.3 4.29 120 9.0 1.250 E: 3.9 13.48 -0.6 1.200 T: 9.6 17.77 0.473 8.4 11.00 120 1.3 1.000 0.00 -0.1 1.049 11.00 0.104 1.1 11.00 120 2.4 1.250 0.00 -0.1 1.200 11.00 0.207 2.3 4.29 120 9.0 1.250 E: 3.9 13.48 -0.6 1.200 T: 9.6 17.77 0.474 8.4 11.00 120 1.3 1.000 0.00 -0.1 1.049 11.00 0.106 1.2 11.00 120 2.4 1.250 0.00 -0.1 1.200 11.00 0.211 2.3 3.96 120 9.0 1.250 E: 3.9 13.48 -0.6 1.200 T: 9.6 17.44 0.483 8.4 11.00 120 1.3 1.000 0.00 -0.1 1.049 11.00 0.108 1.2 11.00 120 2.5 1.250 0.00 -0.1 1.200 11.00 0.213 2.3 3.96 120 9.2 1.250 E: 3.9 13.48 -0.7 1.200 T: 9.6 17.44 0.489 8.5 11.00 120 1.3 1.000 0.00 -0.1 1.049 11.00 0.110 1.2 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 7/11/2011 T:\HASS\MARKM\I FLY\ROOF.SDF JOB TITLE: I Fly Roof Pipe Tag K-fac Add F1 Add F1 To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) Notes To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 14 5.60 19.4 Disch 11.00 120 2.5 419 63.9 14.5 18.3 417 1.250 0.00 -0.1 418 64.2 12.0 37.7 1.200 11.00 0.218 2.4 Pipe: 15 5.60 21.3 Disch 3.96 120 9.4 420 62.3 23.9 37.7 418 1.250 E: 3.9 13.48 -0.7 419 63.9 14.5 59.0 1.200 T: 9.6 17.44 0.500 8.7 Pipe: 16 0.0 0.0 11.00 120 0.1 422 64.2 17.1 0.0 1.000 0.00 -0.1 421 64.4 17.0 0.0 1.049 11.00 0.000 0.0 Pipe: 17 5.60 23.1 Disch 11.00 120 1.1 423 63.9 18.2 0.0 421 1.250 0.00 -0.1 422 64.2 17.1 23.1 1.200 11.00 0.089 1.0 5.60 23.9 Disch Pipe: 18 0.0 4.29 120 6.5 424 62.3 24.7 23.1 422 1.250 E: 3.9 13.48 -0.7 423 63.9 18.2 47.0 1.200 T: 9.6 17.77 0.328 5.8 Pipe: 19 0.0 0.0 11.00 120 0.1 425 64.4 24.8 0.0 1.000 0.00 0.1 426 64.2 24.9 0.0 1.049 11.00 0.000 0.0 Pipe: 20 0.0 0.0 11.00 120 0.1 426 64.2 24.9 0.0 1.250 0.00 0.1 427 63.9 25.0 0.0 1.200 11.00 0.000 0.0 Pipe: 21 0.0 0.0 4.29 120 0.7 428 62.2 25.8 0.0 1.250 E: 3.9 13.48 -0.7 427 63.9 25.0 0.0 1.200 T: 9.6 17.77 0.000 0.0 Pipe: 22 0.0 0.0 10.75 120 0.0 408 62.9 22.7 57.3 403 B3.000 0.00 0.0 404 62.9 22.6 57.3 3.260 10.75 0.004 0.0 Pipe: 23 0.0 57.3 404 10.75 120 0.3 412 62.5 23.0 57.3 407 B3.000 0.00 -0.2 408 62.9 22.7 114.6 3.260 10.75 0.013 0.1 Pipe: 24 0.0 114.6 408 10.75 120 0.4 416 62.3 23.4 57.9 411 B3.000 0.00 -0.1 412 62.5 23.0 172.5 3.260 10.75 0.028 0.3 Pipe: 25 0.0 172.5 412 10.75 120 0.5 420 62.3 23.9 58.3. 415 B3.000 0.00 0.0 416 62.3 23.4 230.8 3.260 10.75 0.048 0.5 Pipe: 26 0.0 230.8 416 10.75 120 0.8 424 62.3 24.7 59.0 419 B3.000 0.00 0.0 420 62.3 23.9 289.8 3.260 10.75 0.073 0.8 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 7/11/2011 T:\HASS\MARKM\I FLY\ROOF.SDF 50B TITLE: I Fly Roof Pipe Tag K-fac Add F1 Add F1 To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) Notes To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 27 0.0 289.8 420 10.75 120 1.1 428 62.2 25.8 47.0 423 B3.000 0.00 0.0 424 62.3 24.7 336.8 3.260 10.75 0.097 1.0 Pipe: 28 0.0 336.8 424 7.50 120 2.7 429 62.2 28.4 0.0 427 B3.000 2E:20.0 20.00 0.0 428 62.2 25.8 336.8 3.260 27.50 0.097 2.7 Pipe: 29 0.0 0.0 75.83 120 28.2 430 29.7 56.6 336.8 428 B3.000 7E:70.0 70.00 -14.1 429 62.2 28.4 336.8 3.260 145.83 0.097 14.1 Pipe: 30 0.0 0.0 2E:20.0 4.50 120 6.7 431 27.2 63.3 336.8 429 B3.000 T:20.0 54.00 -1.0 430 29.7 56.6 336.8 3.260 B:14.0 58.50 0.097 5.6 Pipe: 31 0.0 0.0 97.33 120 10.5 6 14.5 73.8 336.8 430 B4.000 5E:65.0 91.00 -5.5 431 27.2 63.3 336.8 4.260 T:26.0 188.33 0.026 4.9 Pipe: 32 0.0 0.0 11.00 120 1.3 5 14.5 75.1 336.8 431 B4.000 3E:39.0 39.00 0.0 6 14.5 73.8 336.8 4.260 50.00 0.026 1.3 Pipe: 33 0.0 0.0 66.75 120 1.8 4 14.5 76.8 336.8 6 B4.000 0.00 0.0 5 14.5 75.1 336.8 4.260 66.75 0.026 1.8 Pipe: 34 0.0 0.0 3 14.5 77.1 336.8 4 14.5 76.8 336.8 Pipe: 35 0.0 0.0 2 14.5 77.2 336.8 4 3 14.5 77.1 336.8 Pipe: 36 0.0 0.0 1 0.5 83.3 336.8 3 2 14.5 77.2 336.8 Pipe: 37 0.0 0.0 DC1 0.0 83.6 336.8 2 1 0.5 83.3 336.8 B6.000 T:38.0 6.357 24.67 120 38.00 62.67 0.004 50.10 120 B8.000 E:21.0 62.00 8.249 T:41.0 112.10 0.001 B8.000 G: 5.0 8.249 14.00 120 5.00 19.00 0.001 0.2 0.0 0.2 0.1 0.0 0.1 6.1 -6.1 0.0 50.00 140 0.3 D8.000 E:31.0 38.00 -0.2 8.390 G: 7.0 88.00 0.001 0.1 Pipe: 38 0.0 Fixed Pressure Loss Device DC2 0.0 87.6 336.8 1 4.0 psi, 336.8 gpm DC1 0.0 83.6 336.8 Pipe: 39 Source 0.0 SOURCE 0.0 87.6 336.8 DC1 DC2 0.0 87.6 336.8 28.00 140 0.1 D8.000 T:59.0 66.00 0.0 8.390 G: 7.0 94.00 0.001 0.1 DATE: 7/11/2011 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 T:\HASS\MARKM\I FLY\ROOF.SDF JOB TITLE: I Fly Roof NOTES (HASS): (1) Calculations under license were performed by the HASS 8.1 ccinputer program no. 38081321 granted by HRS Systems, Inc. 208 South Public Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to ,provide an average imbalance at each' node of 0.003 gpm and a maximum imbalance at any node of 0.111 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 16.7 ft/sec at pipe 15. ENUE SOUT1-1 it \ r TUKWILA PARKWAY (5. 158th STREET) j ' (o2 1 8" CITY WATER MAIN M z M HI cn /1 EXI EXISTING INDICATOR TING PDC0 —/ POST (AA EXISTING MECHANICAL SPRINKLER ALARM O 31-6' 37\ 26'17 26'17 26-0• EXISTING CONTROL VALVE FOR 2nd FLOOR BUTTERFLY VALVE w/ BUILT IN PER SW. FOR MECH. SERVICE LEVEL. KNOX ENCLOSURE —� PROVIDED BY OTHERS. STANDPIPE DETAIL (6) (5.8) 12.7.1\; �Lt TRASH SITE PLAN SCALE: 1-=20' LL, Sri 11 0.5 WIDE FLANGE BEAM SUPPORTING 3" DEEP 18 GAGE PAN DECKING w/ RIGID INSULATION AND ROOFING ON TOP. WIDE FLANGE BEAM SUPPORTING 2" DEEP PAN DECKING w/ 3" OF CONCRETE ON TOP. 5" TOTAL THICKNESS. / EXIT STAIR TOWER -�� II 1191-IIEI,. W_�1LI 1L1I-TIVr_rI-Ve=11Frnl1 1�l- 911=1 1-1EC 1 ll -W�I11 =IL,-11=II %- E,I =-I • ri IOA1.11- -10-EI I 1B-414[7-2._ �=1-V _II II III Lrfi III I�'I I III W�1J,�11=W i ���Il Jl�r'L=�1 ��I�1F-.tL�ll_lo W111uW1�Ll�'4j4:10 1-0 11 11L' -t=1 �L 11 1��1 it=. X11=111-111sm F-1 W -II -u Il ll-IJIIId1-119 1r11� Il�l�j>�Bn I IF -11 1911 -IB III -I III �II III I 1 II II -IIF illapioNIIJ _ql- 11 1 1 -I I 4k,% -IIEIIE I�fr�Il�llrF17=TE��11=11Fu: II_rE II I�n_IIEI I II I III II =II _ Sd = CI v II IISIIC- I -IF = -I �.I-I I E u 1 X11- - �I I I I_I II��� _�I II - 1 IIF I I I� -IICI I 1 rIICI Ilii OW rl II -I �III.�II-19W1 IIII=119111: I� 1 9 I' I I � II������- 11= �l�-11911 ��CIIIEIIEIII: 11�11�9111�11_�III n �r =LFII �W-i= 91I�_Il -.:.rII -I19.LE�19���� III� 177- 11= 1911' l l 1 -1 ,W II W =111=11 EI 1 -=11 1191111= - -I I - 111 I�I�=�-I III III ISI 11= EIII: LI_ Crll _±„=,A `Ilf4„='�II I' iu)-I1 1111 I�,IIr ff jf llll F_I) �II nE��ICIFIIII rEl 11'I�1k1 1 � I1-11�,(1jIT 1fF�� �X11=7L�iGW- SIF-IIIII�II- I ll1=W�11 ll� ll�€ IIII, ELEVATOf IBI- II III 1 W rIllll � LJ L-IIL-SIL-IIEIIIJII=IIFII�11=117111111111:1--L-11111t%11JIHICI I- I IFI I I I I. PIT �-II- - �I I Jam' IIIIII IIIIII =II _ II -F it -I EII _ I�IIJ'CII=-III IJ I- I- „, 311iti11iiiI11-r1I1111I1 =-�I1I1 -_=='EI1n I1Lid-llI- _ 9 II1IIII1� EIR d l_I_-= W'l �� 9F �-;J � -1-1C1I 1��_ IlIllIC dc1ll IlI1J__==_I 1= 111I EE�_ �I1i n1119�_-"II1I1II1 9 I s�u - 1 111 _m_ -III-1 i _I��II_IICII �II_III-11111 .-�II�II_II �I -11_11 �_II��11_ICIII�II_IIHI�II_II-rJ�lI-I�IIY��...J�il-1���11=11�11�11-II�III �II ;t:14%- - EIIIIu-1 9 - 1I I - - - I II III= IIFT�II-IEI �11=11 11111=11 II��I-__CII�T�11=11 I I -u- I WI III_III�II�II_III 111 ll�I l�I��IEJI = =W =I FW = II'W�1�I='EI- I �I 1= 1111=1�IT IHI III IL-I�III 11=11 EIII�II=11111 I II_ -1 u 1� W - �_ (IIEI _IIIA= I L G 1 - I J I 11' -- _ 1L1� I -I I rI,I 1-111-19IIII'' IIIIII llhll��ld F=ILII6L�11=11 Ill _II 11Id 11=11811 ITS rt0a Ig� g a� AvizL I BUILDING SECTION �11W� =I 1LII=11 AVO-111„ IITE'�I�I�" I_III. 3-III 1 � I_ IIBII- �u- 31 111 EIl�I S��IIII q.W -nlmteXI�__-1l1.11 I1 1 �19ll�Xn--11W==Ilu�1I �9�e1Il1�l-1- IIldW1WW - 11=1--IBIIBII=111L_J1 l_I1L11 1 1 NIII_ 1 _J J ✓yt� 4 ` . z,_ h ti CD 8X3-2 C> ' —111-111-111=I 11=111-1 11-111-111=111-111-111-111- 1I 1=1 11=1 11=1 I_I=1 I I=1 11=1 11=1 I_I=1 11=1 11=1 11=1 11=1 I I 111-111-111-111=11_1=111=111-111=111=111=111-111- 111-11 I-11 I-111-111=111 111-111-1 I I-11 I -111=1T -TI —I 11=111-111-111=111_11 1 111-111—i 11-111-111-111- 11711=1117111_111E111—111-111_111=1i1-111—III I l l t =1 I I=1 I I=1 =1 i t=111-111=111_111E11I-, I I -III -I I I- I 1=111=111=111 III 111=111-111=111=11 1=111 II _ _ _ -111-111-111-111-111-111-111-111-111-111-111-111 111-111-111-I I 1=111=111-111=111=111-111-111 111=111 -11 1-11 1-11 1-1 I I-11=11=111=111-111=111_111=111= 111=111=111=111_111E1 1=111=11=11=111 1 � =111=1 1 1 -111-111=111-111-111-111-111=111-111_111_11111_11- 111=111 111=111=1 � -111-11-111=T=ll 1=11_11-111 E111 -111E111 =1 11=1 11=1 I I—I 11=1 11=1 I I—I 11=1 11:11 1= 111 1 11=11=111=11=111=11=111=111=11=111=111=-111 '"'—"�_� �=1 i 1-1 11=1 111 I I - RISER LEGEND STANDPIPE DETAIL 1 EXISTING 8" GRINNELL MODEL A ALARM VALVE 111-111-111-111=111=111=111=111-111=111-111-111-111-111111-11 I- 111 111 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 -111-111-111=111=1=1 I I -III -III -III -II I -I 1=1 I -I 11=1 11=1 11=1 I- 11=111-111-111-11=111-11=11=111-111=111=111=111-111-111-11-1 - I=1 11=1 11=1 11=1 11=1 11=1 1 1=1 I I=1 11—i 11=1 I 11111=1 11=1 11 I I - II — I 111-111111-111-111—III-111-111 M 111-I II 111 II I I I II -11=111=111=111=1 I I=111=111=111=111=111=111=111=111=111111=111- 11__=111=11=111=111=111111=111=111111111111111=111_-1 I i 111 __ I _ _ __ __ _ _ _ _ 1 1 i = 1 1=1 I=11=11=111=111=III_ _IIIIIIIII111 I I I 111IIIi I I I I I I • I I-111=111=111=1 i 1=111=111=1 i 1=111=1 I I=1 I I=111=111=111=1 I I—II I—i -11 I-1 I i-111-111-111-111-111-111-111-111-111-111-11 I-111-111-111- 111=111=111=111-111=1 1 1=111=111=111=111-111=111=111=111=111=111-1 -111=111-111-111-111-111-111-111=111=111-111-111-111=111-111=111- 1111=111=Ti-Ti111-111-111=111=111111-111-111-111=11_111-1 —Ill ill 111=111—III—IV-111=111=111 111=111—ill—Ill-111=111=111- 11=111=111=111=111-111-111=111=111=111=111—I 11=111=111-111-1 I ed -111=111111=111=111=111=111=111,,-111=111=111=111=111=111=111=1 I i - it I i i—I i � 1—III_ EXISTING RISER DETAIL FP -1 SCALE: r=1' -c' SCALE: 1..1,-0- U . G. "=1'-0 Without Comments As Noted in Red Per The Attached Letter 7 -, ,,se pians have been reviewed by The Tukwila Fire ,:-rention Bureau for conformance with current City ,dards. Acceptance is subject to errors and iissions which do not authorize violations of adopted .Indards and ordinances. The responsibility for the •.equacy of design rests totally with the designer. -Jditions, deletions or revisions to these drawings after alis date Will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by rhe Tukwila Fire Prevention Bureau. Date: By: 4 "i*,c,. I-e,,ofs r�. he��tl. b- ',ore 6 c.h1 r. t-ewt,;Lk "LKSftI! a' perk,ctIAN't r- -a S��`� ot. delvtne. ,4tfv rYO s py.44100 2 d.t'y . V4 Ivo- "• /f Y dv054-441c. -I--est recv; d y, Cor -6,01 VtYL' . b 7-e 7 es 0,41e, OFC,4,4i-1 p✓CSf 4,^2. if. _$ 1•„,0ke 4-5 . -ib �e_...011STAliiJ 441,.0)1 r ckiee - e- NFrA 2)- Y' .C11 t- Fe - ye.,„,„( VicLvtStiras IAAS qfp Q V h v pvc.vc (t5 �Z✓w..�' . TUKWILA FIRE DEPARTMENT Please cal( 206-575-4407 and give this Fire Permit No. //-3—« and exact address for shut- down hutdown or restoration approval. U.G. NOTES 1 THIS SITE PLAN IS FOR REFERENCE ONLY. SEE ARCHITECTURAL AND CML DRAWINGS FOR ADDITIONAL SITE PLAN INFORMATION. 2 UNDERGROUND PIPING IS EXISTING. FLOW TEST STATIC RESIDUAL FLOW SOURCE LOCATION 120 20 13,000 CITY OF TUKWILA WATER SITE NOTICE Weld stamps must be inspected before pipe is hung. Do not paint piping pr!o.- to hydrostatic test FILE COPY PMD JUL 11 2011 TUKWILA FIRE 72 Vcr HANGER LEGEND A "U" HOOK B COACH SCREW ROD D BM. CLAMP W/ "STRAP E EYELET F HDI—P G CEILING FLANGE H SIDE BEAM BRACKET K SHORT CLIP M ALL THREAD ROD N TOGGLE NUT P POWDER DRIVEN STUD R EXPANSION BOLT S PIPE SPIKE T U V W X Y Z FITTING LEGEND P PIPE -O -LET F PLAIN END FIT FITTING SN GROOVED SHAPED NIPPLE TSN THREADED SHAPED NIPPLE ---,..- 2 - WAY EARTHQUAKE BRACE 4 WAY - EARTHQUAKE BRACE n STRUCTURE PIPE IN TO CINCHESENTER j`� SPRINKLER LEGEND y aice r ti ►_- SPRINKLER ORIFICE SIZES AND TYPE = O i i c W a W N 1- in 1 5 3 7 1 0 ® 1/2 2 16 8 16 2 SPRAY QOlip1” Ask 3 17 O 3/4" 4 32 SPRAY 1- 1 3 7 1 < Q 1/2 2 8 16 2 SIDEWALL a° ® 1" 1" DRY TYPE O ,1" 2 ® 40 1" STATE CERTIFICATION TEMP RATING SPRINKLERS UP AND DOWN \ OPENING ""1 Na UP a m z3 O 165° 3- N Z a O -e- 212° ® 1" Q 286° ® 1/2 �` s9 ogre 350° 1" rste. illi» .n 500° ® 1/2 171W61� & APPROVAL REQUIRED '�L�i�`��j_ � CITY OF TUKWILA cagy Decem SPRINKLER HEADS USED SYM MANUF MODEL TYPE THREAD SIZE ORIFICE SIZE HEAD FINISH ESCUTCH FINISH TEMP QTY TOTAL XX QUAUTY CONTROL BY Kevin Marr DATE 4/14/2011 • APPROVED FOR FABRICATION BY DATE GENERAL NOTES 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL LISTED OR FM APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISERS AND DIMENSIONS SHOWN THUSLY (1-6) WHICH ARE END TO END. 3. EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPLICABLE EDITION 4. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPLICABLE EDITION. 5. PIPING SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPLICABLE EDITION 6. JOINING OF PIPE AND FITTINGS, THREADED & WELDED, SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPUCABLE EDITION. 7. OWNER TO PROVIDE ADEQUATE HEAT IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM TO PREVENT WATER IN PIPES FROM FREEZING. 8. ALL WIRING OF ELECTRICAL DEVICES (IF REQUIRED) TO BE PROVIDED BY OTHERS 9. PAINTING OF PIPE & EQUIPMENT (IF REQUIRED) TO BE PROVIDED BY OTHERS 10. FURRING OF PIPE & EQUIPMENT (IF REQUIRED) TO BE PROVIDED BY OTHERS DESIGN CRITERIA r. PIPE NOTES REVISIONS NO DATE BY DESCRIPTION 1 5/31/1 I MM ADD 2ND FLK CONTROL VALVE PER TUKWILA 2 7/1 1/I I MM ADD SPRINKLERS AT MECH. SERVICE LEVEL CONTRACT WITH: RUSHFORTH CONSTRUCTION CO. INC. 6012 12th STREET EAST STE 100 TACOMA, WA 98424 Phil Milionis PROJECT NAME: —FLY INDOOR SKYDIVING 31/1381—TUKWILA PARKWAY TUKWILA, WA 98188 349 TUKWILA PKWY 11-S-150 PATRIFP099CF ATR OT WWW PATRIOTFIRE.COM t =Inn TEL(253)926 -2290 2707 70TH AVENUE EAST FAX 253 922-6150 TACOMA, WA 98424 ,- bobf®potriotfire.com DESIGNER Bob Forsberg. SHEET ' F pl . DATE . April 12, 2011 ( JOB NO. 11-1798 _ OF 1 4,_ �AA� 104"0 II1 g" 16' — 1 ft 7 -177 01 0 ROOF -------------- • 431, 'f8X1 / x I W8X10 TOLCO AG 75 ATR. RESTRAINT ATR LENGTH =1.4 TIMES HANGER ROD LENGTH. MAX LENGTH 30' j67 00 03 16X67 <3, W6X15 :148X10 W8X10 r -w '418X10 8X10 1 4r, W6X15, COSYk 0 !( i 1.8 2.5 1---�--_---- --- z1i \ �. // CONFIRMML 2. CATION AND fi IZE OF Oif R CVLL£C -- --_ 00 03 16X67 <3, W6X15 :148X10 W8X10 r -w '418X10 8X10 1 4r, W6X15, COSYk 0 !( i 1.8 2.5 1---�--_---- --- z1i \ / j i j vr,t W1 X33 -- --_ LOW LOW ROOF LEVEL WEDGE ANCHOR AT 1ST FLOOR SAMMY X -PRESS 20 AT 2ND FLOOR ATR PER PLAN r RING HANGER w/ SURGE RESTRAINT CLIP END OF LINE RESTRAINT 2" DEEP 20 GAGE PAN DECK WITH 3" OF CONCRETE ON TOP AT FOR 2ND FLOOR DECK. 5" TOTAL THICKNESS. 3" DEEP 18 GAGE PAN DECK AT LOWER ROOF DECK. SCALE: 1/8"=1•-0" 1111 e"N II II II II 4.5 5.2 AA 13' —104"0'-187" 16' 9 36- II 1 If 0 0 7 ROOF W27 1.8 6X15 \'r /6X15 W16X67 W8X10 I�0-EDF OPE PER S 1 -EO O5 BOD \ \ �Fs 7 t, 16X-35 11/4 9-10 11/4 W16X6 T al W6X15 .1-0 W6X15 3.5 REMOTE AREA (.15/1,9500 SYSTEM DEMAND: 337 GPM @ 83.3 PSI AT BASE OF RISER 11-0 e'—'L) 11-0 27X8--- 4.5 5.2 W10X33 WIDE FLANGE BEAM PER PLAN. SERVICE LEVEL II II II II II II SCALE: 1/8"=1'-0" GENERAL NOTES 1 NOT USED 2 TYPICAL HANGER TO BE SAMMY X -PRESS OR BEAM CLAMP, ATR AND RING HANGER. 3 ALL WELDED PIPE TO BE IMPRESSION STAMPED. 4 ALL SERVICE LEVEL PIPING IS GALVANIZED. TOLCO FIG 828 TO BUILDING TO BUILDING STRUCTURE. TOLCO FIG 980 EQ. END. 45'-60' FROM VERTICAL TOLCO FIG 4L TO PIPE. LONGITUDNAL EQ BRACE NTS WIDE FLANGE BEAM PER PLAN. TOLCO FIG 828 TO BUILDING TO BUILDING STRUCTURE. TOLCO FIG 980 EQ. END. 45'-60' FROM VERTICAL TOLCO FIG 1001 TO PIPE. LATTERAL EQ BRACE NTS P"N Lop N N 0 N) CV LOICD A B D E F G H K M N P R S HANGER LEGEND "U" HOOK COACH SCREW ROD BM. CLAMP W/10"STRAP EYELET HDI—P CEILING FLANGE SIDE BEAM BRACKET SHORT CLIP ALL THREAD ROD TOGGLE NUT POWDER DRIVEN STUD EXPANSION BOLT PIPE SPIKE T U V W X SAMMY X—PRESS XP 20 Y Z FITTING LEGEND P PIPE -0 -LET F PLAIN END FIT FITTING SN GROOVED SHAPED NIPPLE TSN THREADED SHAPED NIPPLE 2 - WAY EARTHQUAKE BRACE 4 - WAY EARTHQUAKE BRACE STRUCTURE TO CENTER UNE OF PIPE IN INCHES SPRINKLER LEGEND C N O a. = tn1- SPRINKLER ORIFICE SIZES AND TYPE 0 t� re a Z z z W a W N 1-U, 2 5 3 7 1 SPRAY 16 8 16 2 0 O • 3 4 17 32 SPRAY ❑O • 2 8 7 1 8 16 2 SIDEWALL d 1/2 1" 3/4" 1" 1/2 a 1" 2 DRY TYPE O 1- 1. 1" STATE CERTIFICATION TEMP RATING O 1650 — e— 212° O 286° agE 350° 500° z tn WIC O z O Z Z a a. N j 0 za a 0 J m 1 } N 1/2" a z Z �3 zp W O O 1" 1" 1" 1/2" 1/2 1" 1/2 APPROVAL REQUIRED CITY OF TUKWILA SPRINKLER HEADS USED SYM MANUF MODEL TYPE THREAD SIZE ORIFICE SIZE HEAD FINISH ESCUTCH FINISH TEMP QTY -e- RELUIBIE F1FR. WNW I• 2 5.6K BRONZE 200' 8 TOTAL QUALITY CONTROL BY DATE APPROVED FOR FABRICATION BY DATE GENERAL NOTES 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL LISTED OR FM APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISERS AND DIMENSIONS SHOWN THUSLY (1-6) WHICH ARE END TO ENO. 3. EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPUCABLE EDITION 4. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPUCABLE EDITION. 5. PIPING SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPUCABLE EDITION 6. JOINING OF PIPE AND FITTINGS, THREADED & WELDED, SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPLICABLE EDITION. 7. OWNER TO PROVIDE ADEQUATE HEAT IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM TO PREVENT WATER IN PIPES FROM FREEZING. 8. ALL WIRING OF ELECTRICAL DEVICES (IF REQUIRED) TO BE PROVIDED BY - OTHERS 9. PAINTING OF PIPE & EQUIPMENT (IF REQUIRED) TO BE PROVIDED BY OTHERS 10. FURRING OF PIPE & EQUIPMENT (IF REQUIRED) TO BE PROVIDED BY OTHERS DESIGN CRITERIA 1 DESIGNED PER NFPA 13, 2010 EDITION. 2 ORDINARY HAZARD GROUP I PIPE NOTES 1 ALL THREADED PIPE TO BE GALVANIZED SCH 40. 2 ALL WELDED PIPE TO BE GALVANIZED SCH 10. 3 ALL WELDED PIPE TO BE IMPRESSION STAMPED. REVISIONS NO DATE BY DESCRIPTION CONTRACT WITH: RUSHFORTH CONSTRUCTION CO. INC. 6012 12th STREET EAST STE 100 TACOMA, WA 98424 Phil Milionis PROJECT NAME: I—FLY INDOOR SKYDIVING -WI TUKWILA PARKWAY TUKWILA, WA 98188 ATRI 2707 70TH AVENUE EAST TACOMA, WA 98424 PATRIFP099CF OT WWW.PATRIOTFIRE.COM TEL (253) 926-2290 FAX (253) 922-6150 bobfepatriotfire.com DESIGNER MARK METZGER SHEET DATE JULY 7, 2011 JOB NO. 11-1798 3 of 3 FP3 Pacific Rim Fire Code Consulting, PLLC April 29, 2011 Bob Forsberg Patriot Fire Protection, Inc. 2707 70th Ave E Tacoma, WA 98424 Project: I -Fly Indoor Skydiving 3y� ,39-1 Tukwila Parkway Tukwila, WA 98188 Subject: Independent Third Party Review — Modification of Fire Sprinkler System Dear Mr. Forsberg: As requested, 1 have performed an Independent Third Party Plan Review on the fire sprinkler system modification for the above referenced project. The following were reviewed: • Fire Sprinkler Drawing — Sheets FP -1 and FP -2 dated April 12, 2011 bearing your State of WA Level I11 stamp • Hydraulic Calculations dated 4/14/2011 bearing your State of WA Level 111 stamp The documents were reviewed for compliance with the 2010 edition of NFPA 13, Installation of Sprinkler Systems and Tukwila Municipal Code Chapter 16.42, Sprinkler Systems. I have found the fire sprinkler design to be acceptable subject to the following comments: 1. Review was based on design criteria provided by Patriot Fire of 0.15gpm/s.f. over 1500s.f. Review is limited to the addition for the I -Fly space. 2. Per Patriot Fire an existing backflow prevention device is assumed to be installed outside in the vault. If there is not an existing backflow prevention device and one is added, the hydraulic calculations will need to be updated to reflect the additional friction loss. The safety margin available based on the current calculations and reported water supply should easily accommodate the addition. 3. An additional sprinkler is needed at the north end of Hallway 109 on the first floor to provide proper spacing to the north wall. Patriot Fire has indicated that this sprinkler will be added prior to submittal to the Tukwila Fire Department. Pacific Rim Fire Code Consulting, PLLC 4. The detail call -out on Sheet FP2 to detail "B/FP1" needs to be changed to call out detail "C/FP1" to properly indicate the standpipe detail. This call -out occurs at the stairway in the NW corner of the space on both the first and second floor plans. Patriot Fire has indicated that this changed will be made prior to submittal to the Tukwila Fire Department. A resubmittal to PRFCC is not required provided the above comments are addressed to the satisfaction of Tukwila Fire Department. The comments made above do not relieve the contractor from compliance with requirements of contract drawings, specifications, codes or standards. PRFCC has performed a review of the submittal for general conformance with the standards referenced. Please contact me at 360-259-1627 or anderson@prfcc.com with any questions regarding this review. Sincerely, Pacific Rim Fire Code Consulting, PLLC Carl Anderson, PE Principal, WA PE License 31714 (Fire Protection Engineering) t-tg1a�y PATRIOT FIRE PROTECTION, INC 2707 70th AVENUE EAST TACOMA,WA 98424 HYDRAULIC CALCULATIONS FOR I -Fly Tukwilia, WA FILE NUMBER: DATE: APR 14, 2011 /<-5-OV -DESIGN DATA - OCCUPANCY CLASSIFICATION: Ordinary Hazard DENSITY: .15 gpm/sq. ft. AREA OF APPLICATION: 1500 sq. ft. COVERAGE PER SPRINKLER: 126 sq. ft. max NUMBER OF SPRINKLERS CALCULATED: 21 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 478.3 gpm TOTAL WATER REQUIRED (including hose): 728.4 gpm FLOW AND PRESSURE (@ BOR, Node 1) 478.4 gpm @ 74..4 psi SPRINKLER ORIFICE SIZE: 5.6 K NAME OF CONTRACTOR: Patriot Fire Protection DESIGN/LAYOUT BY: Bob Forsberg AUTHORITY HAVING JURISDICTION: City of Tukwila CONTRACTOR CERTIFICATION NUMBER: PATRIFP099CF CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 38081321) HRS SYSTEMS, INC. PETERSBURG, TN 37144 PETERSBURG, TN 37144 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE .4/14/2011 JOB TITLE: I Fly 2nd Floor WATER SUBTLY DATA T:\HASS\BOBF\I-FLY 2ND FLOOR.SDF STATIC RESID. FLOW AVAIL. TOTAL REQ'D PRESS. PRESS. @ PRESS. @ DEMAND PRESS. (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) CITY 120.0 20.0 13000.0 119.5 728.4 82.9 Required pressure is 36.6 psi (31%) less than available pressure. AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 728.4 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 250.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 478.4 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) CITY 0.0 SOURCE 82.9 478.4 DC1 0.0 - - - - 82.8 DC2 0.0 74.8 1 0.5 74.4 2 13.0 68.9 3 14.5 68.0 4 14.5 67.5 5 14.5 62.4 6 14.5 61.5 10 14.5 60.2 11 14.5 51.8 12 14.5 47.5 20 26.8 37.8 30 26.8 35.6 31 26.8 27.8 32 26.8 26.8 33 26.8 26.2 34 26.8 26.1 35 26.8 25.9 35A 26.8 25.8 36 26.8 25.2 37 26.8 24.8 41 26.8 18.3 42 26.8 14.9 43 26.8 13.0 44 26.8 9.9 45 26.8 23.1 46 26.8 23.0 47 26.8 22.3 48 26.8 19.9 49 37.5 - - - - 11.5 S200 26.8 K= 5.60 23.1 26.9 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 4/14/2011 T:\HASS\BOBF\I-FLY 2ND FLOOR.SDF JOB TITLE: I Fly 2nd Floor NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 5201 26.8 K= 5.60 21.3 25.8 S202 26.8 K= 5.60 25.3 28.2 5203 26.8 K= 5.60 25.1 28.0 S204 26.8 K= 5.60 26.2 28.7 5205 26.8 K= 5.60 14.4 21.2 S206 26.8 K= 5.60 13.1 20.2 5207 26.8 K= 5.60 11.7 19.1 S208 26.8 K= 5.60 10.6 18.2 5209 26.8 K= 5.60 10.1 17.8 S210 26.8 K= 5.60 9.2 17.0 S211 26.8 K= 5.60 8.4 16.3 S212 26.8 K= 5.60 7.6 15.5 S213 24.4 K= 5.60 23.2 27.0 S214 24.4 K= 5.60 23.0 26.9 S215 26.8 K= 5.60 25.7 28.4 S216 24.4 K= 5.60 22.4 26.5 S217 37.8 K= 5.60 8.3 16.2 S218 38.8 K= 5.60 7.0 14.8 S219 26.8 K= 5.60 24.7 27.8 5220 26.8 K= 5.60 24.7 27.8 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 4/14/2011 T:\HASS\BOBF\I-FLY 2ND FLOOR.SDF JOB TITLE: I Fly 2nd Floor PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 478.4 8.390 PL 25.00 PF 0.1 CITY 0.0 SRCE 82.9 (N/A) 2.8 140 FTG TG PE 0.0 DC1 0.0 0.0 82.8 0.0 0.001 TL 91.00 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE DC1 0.0 0.0 82.8 0.0 8.0 psi, 478.3 gpm DC2 0.0 0.0 74.8 0.0 Pipe: 3 478.3 8.390 PL 53.00 PF 0.1 DC2 0.0 0.0 74.8 0.0 2.8 140 FTG EG PE -0.2 1 0.5 0.0 74.4 0.0 0.001 TL 91.00 PV Pipe: 4 478.3 7.981 PL 13.04 PF 0.1 1 0.5 0.0 74.4 0.0 3.1 120 FTG A PE -5.4 2 13.0 0.0 68.9 0.0 0.002 TL 44.04 PV Pipe: 5 478.3 7.981 PL 50.58 PF 0.2 2 13.0 0.0 68.9 0.0 3.1 120 FTG ET PE -0.6 3 14.5 0.0 68.0 0.0 0.002 TL 103.58 PV Pipe: 6 478.3 6.065 PL 24.75 PF 0.5 3 14.5 0.0 68.0 0.0 5.3 120 FTG T PE 0.0 4 14.5 0.0 67.5 0.0 0.009 TL 54.75 PV Pipe: 7 478.3 4.026 PL 66.83 PF 5.1 4 14.5 0.0 67.5 0.0 12.1 120 FTG E PE 0.0 5 14.5 0.0 62.4 0.0 0.066 TL 76.83 PV Pipe: 8 478.3 4.260 PL 5.50 PF 0.9 5 14.5 0.0 62.4 0.0 10.8 120 FTG E PE 0.0 6 14.5 0.0 61.5 0.0 0.050 TL 18.50 PV Pipe: 9 478.3 4.260 PL 13.33 PF 1.3 6 14.5 0.0 61.5 0.0 10.8 120 FTG E PE 0.0 10 14.5 0.0 60.2 0.0 0.050 TL 26.33 PV Pipe: 10 478.3 3.260 PL 25.67 PF 8.4 10 14.5 0.0 60.2 0.0 18.4 120 FTG T PE 0.0 11 14.5 0.0 51.8 0.0 0.185 TL 45.67 PV Pipe: 11 478.3 3.260 PL 2.92 PF 4.2 11 14.5 0.0 51.8 0.0 18.4 120 FTG T PE 0.0 12 14.5 0.0 47.5 0.0 0.185 TL 22.92 PV Pipe: 12 478.3 3.260 PL 13.75 PF 4.4 12 14.5 0.0 47.5 0.0 18.4 120 FTG E PE -5.3 20 26.8 0.0 37.8 0.0 0.185 TL 23.75 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 4/14/2011 T:\HASS\BOBF\I-FLY 2ND FLOOR.SDF JOB TITLE: I Fly 2nd Floor PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 478.3 3.260 PL 2.00 PF 2.2 20 26.8 0.0 37.8 0.0 18.4 120 FTG E PE 0.0 30 26.8 0.0 35.6 0.0 0.185 TL 12.00 PV Pipe: 14 478.3 3.260 PL 22.25 PF 7.8 30 26.8 0.0 35.6 0.0 18.4 120 FTG T PE 0.0 31 26.8 0.0 27.8 0.0 0.185 TL 42.25 PV Pipe: 15 425.6 3.260 PL 6.50 PF 1.0 31 26.8 0.0 27.8 0.0 16.4 120 FTG ---- PE 0.0 32 26.8 0.0 26.8 0.0 0.149 TL 6.50 PV Pipe: 16 369.4 3.260 PL 5.25 PF 0.6 32 26.8 0.0 26.8 0.0 14.2 120 FTG ---- PE 0.0 33 26.8 0.0 26.2 0.0 0.115 TL 5.25 PV Pipe: 17 224.0 3.260 PL 0.42 PF 0.0 33 26.8 0.0 26.2 0.0 8.6 120 FTG ---- PE 0.0 5204 26.8 5.6 26.2 28.7 0.045 TL 0.42 PV Pipe: 18 195.4 3.260 PL 3.92 PF 0.1 5204 26.8 5.6 26.2 28.7 7.5 120 FTG ---- PE 0.0 34 26.8 0.0 26.1 0.0 0.035 TL 3.92 PV Pipe: 19 168.4 3.260 PL 7.42 PF 0.2 34 26.8 0.0 26.1 0.0 6.5 120 FTG ---- PE 0.0 35 26.8 0.0 25.9 0.0 0.027 TL 7.42 PV Pipe: 20 141.5 3.260 PL 3.00 PF 0.1 35 26.8 0.0 25.9 0.0 5.4 120 FTG ---- PE 0.0 35A 26.8 0.0 25.8 0.0 0.019 TL 3.00 PV Pipe: 21 141.5 2.157 PL 0.67 PF 0.1 35A 26.8 0.0 25.8 0.0 12.4 120 FTG ---- PE 0.0 S215 26.8 5.6 25.7 28.4 0.145 TL 0.67 PV Pipe: 22 113.1 2.157 PL 5.58 PF 0.5 S215 26.8 5.6 25.7 28.4 9.9 120 FTG ---- PE 0.0 36 26.8 0.0 25.2 0.0 0.096 TL 5.58 PV Pipe: 23 86.6 2.157 PL 6.92 PF 0.4 36 26.8 0.0 25.2 0.0 7.6 120 FTG ---- PE 0.0 37 26.8 0.0 24.8 0.0 0.059 TL 6.92 PV Pipe: 24 55.6 2.157 PL 2.50 PF 0.1 37 26.8 0.0 24.8 0.0 4.9 120 FTG ---- PE 0.0 S219 26.8 5.6 24.7 27.8 0.026 TL 2.50 PV Pipe: 25 27.8 2.157 PL 7.83 PF 0.1 S219 26.8 5.6 24.7 27.8 2.4 120 FTG ---- PE 0.0 5220 26.8 5.6 24.7 27.8 0.007 TL 7.83 PV i SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 4/14/2011 T:\HASS\BOBF\I-FLY 2ND FLOOR.SDF JOB TITLE: I Fly 2nd Floor PIPE TAG Q(GPM) DIA(IN) LENGTH .PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 26 52.7 1.049 PL 0.96 PF 4.7 31 26.8 0.0 27.8 0.0 19.6 120 FTG T PE 0.0 S200 26.8 5.6 23.1 26.9 0.783 TL 5.96 PV Pipe: 26A 25.8 1.049 PL 9.00 PF 1.9 5200 26.8 5.6 23.1 26.9 9.6 120 FTG ---- PE 0.0 S201 26.8 5.6 21.3 25.8 0.209 TL 9.00 PV Pipe: 27 56.2 1.610 PL 5.67 PF 1.5 32 26.8 0.0 26.8 0.0 8.9 120 FTG T PE 0.0 5202 26.8 5.6 25.3 28.2 0.109 TL 13.67 PV Pipe: 28 28.0 1.610 PL 9.00 PF 0.3 5202 26.8 5.6 25.3 28.2 4.4 120 FTG ---- PE 0.0 5203 26.8 5.6 25.1 28.0 0.030 TL 9.00 PV Pipe: 29 145.3 1.610 PL 4.50 PF 7.9 33 26.8 0.0 26.2 0.0 22.9 120 FTG T PE 0.0 41 26.8 0.0 18.3 0.0 0.634 TL 12.50 PV Pipe: 30 103.9 1.610 PL 10.00 PF 3.4 41 26.8 0.0 18.3 0.0 16.4 120 FTG ---- PE 0.0 42 26.8 0.0 14.9 0.0 0.340 TL 10.00 PV Pipe: 31 66.5 1.380 PL 6.08 PF 1.9 42 26.8 0.0 14.9 0.0 14.3 120 FTG ---- PE 0.0 43 26.8 0.0 13.0 0.0 0.316 TL 6.08 PV Pipe: 32 31.7 1.049 PL 10.00 PF 3.1 43 26.8 0.0 13.0 0.0 11.8 120 FTG ---- PE 0.0 44 26.8 0.0 9.9 0.0 0.306 TL 10.00 PV Pipe: 33 41.5 1.049 PL 2.83 PF 3.9 41 26.8 0.0 18.3 0.0 15.4 120 FTG T PE 0.0 5205 26.8 5.6 14.4 21.2 0.501 TL 7.83 PV Pipe: 34 20.2 1.049 PL 10.00 PF 1.3 S205 26.8 5.6 14.4 21.2 7.5 120 FTG ---- PE 0.0 S206 26.8 5.6 13.1 20.2 0.133 TL 10.00 PV Pipe: 35 37.3 1.049 PL 2.83 PF 3.2 42 26.8 0.0 14.9 0.0 13.9 120 FTG T PE 0.0 S207 26.8 5.6 11.7 19.1 0.413 TL 7.83 PV Pipe: 36 18.2 1.049 PL 10.00 PF 1.1 S207 26.8 5.6 11.7 19.1 6.8 120 FTG ---- PE 0.0 5208 26.8 5.6 10.6 18.2 0.109 TL 10.00 PV Pipe: 37 34.8 1.049 PL 2.83 PF 2.8 43 26.8 0.0 13.0 0.0 12.9 120 FTG T PE 0.0 S209 26.8 5.6 10.1 17.8 0.362 TL 7.83 PV DATE: 4/14/2011 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 T:\HASS\BOBF\I-FLY 2ND FLOOR.SDF JOB TITLE: I Fly 2nd Floor PIPE TAG Q(GPM) END ELEV. NOZ. PT DISC. VEL(FPS) NODES (FT) (K) (PSI) (GPM) Pipe: 38 S209 26.8 5210 26.8 Pipe: 39 44 26.8 S211 26.8 Pipe: 40 S211 26.8 S212 26.8 Pipe: 41 34 26.8 45 26.8 Pipe: 42 45 26.8 S213 24.4 Pipe: 43 35 26.8 46 26.8 Pipe: 44 46 26.8 S214 24.4 Pipe: 45 36 26.8 47 26:8 Pipe: 46 47 26.8 S216 24.4 Pipe: 47 37 26.8 48 26.8 Pipe: 48 48 26.8 49 37.5 Pipe: 49 49 37.5 S217 37.8 Pipe: 50 S217 37.8 S218 38.8 5.6 10.1 5.6 9.2 0.0 9.9 5.6 8.4 5.6 8.4 5.6 7.6 0.0 26.1 0.0 23.1 0.0 23.1 5.6 23.2 0.0 25.9 0.0 23.0 0.0 23.0 5.6 23.0 0.0 25.2 0.0 22.3 0.0 22.3 5.6 22.4 0.0 24.8 0.0 19.9 0.0 19.9 0.0 11.5 0.0 11.5 5.6 8.3 5.6 8.3 5.6 7.0 DIA(IN) LENGTH HW(C) (FT) FL/FT 17.0 1.049 PL 17.8 6.3 120 FTG 17.0 0.096 TL 31.7 0.0 11.8 16.3 1.049 PL 120 FTG 0.306 TL PRESS. SUM. (PSI) 10.00 PF 1.0 ---- PE 0.0 10.00 PV 2.83 PF 1.5 E PE 0.0 4.83 PV 15.5 1.049 PL 10.00 PF 0.8 16.3 5.7 120 FTG ---- PE 0.0 15.5 0.081 TL 10.00 PV 27.0 1.049 PL 7.92 PF 2.9 0.0 10.0 120 FTG T PE 0.0 0.0 0.226 TL 12.92 PV 27.0 1.049 PL 0.0 10.0 120 FTG 27.0 0.226 TL 2.33 PF 1.0 E PE 1.0 4.33 PV 26.9 1.049 PL 7.92 PF 2.9 0.0 10.0 120 FTG T PE 0.0 0.0 0.225 TL 12.92 PV 26.9 1.049 PL 0.0 10.0 120 FTG 26.9 0.225 TL 2.33 PF 1.0 E PE 1.0 4.33 PV 26.5 1.049 PL 7.92 PF 2.8 0.0 9.8 120 FTG T PE 0.0 0.0 0.219 TL 12.92 PV 26.5 1.049 PL 0.0 9.8 120 FTG 26.5 0.219 TL 31.0 1.049 PL 0.0 11.5 120 FTG 0.0 0.292 TL 31.0 1.049 PL 0.0 11.5 120 FTG 0.0 0.292 TL 31.0 0.0 11.5 16.2 1.049 PL 120 FTG 0.292 TL 14.8 1.049 PL 16.2 5.5 120 FTG 14.8 0.075 TL 2.33 PF 0.9 E PE 1.0 4.33 PV 11.67 PF 4.9 T PE 0.0 16.67 PV 10.75 PF 3.7 E PE -4.7 12.75 PV 6.50 PF 3.1 2E PE -0.1 10.50 PV 12.00 PF 0.9 ---- PE -0.4 12.00 PV DATE: 4/14/2011 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 T:\HASS\BOBF\I-FLY 2ND FLOOR.SDF JOB TITLE: I Fly 2nd Floor NOTES (HASS): (1) Calculations under license were performed by the HASS 8.1 computer program no. 38081321 granted by HRS Systems, Inc. 208 South Public Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.003 gpm and a maximum imbalance at any node of 0.130 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 22.9 ft/sec at pipe 29. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: A Diameter (in) 1.049 1.380 1.610 4.026 6.065 7.981 MATERIAL: S40 HWC: 120 Equivalent Fitting Lengths in Feet E T L C B G A Ell Tee LngEll ChkVly BfyVly GatVly AlmChk D N DPV1v NPTee R 2.00 1.00 3.00 1.00 4.00 1.00 10.00 0.00 14.00 0.00 18.00 0.00 5.00 6.00 8.00 20.00 30.00 35.00 2.00 5.00 6.00 1.00 10.00 10.00 2.00 7.00 6.00 1.00 10.00 10.00 2.00 9.00 6.00 1.00 10.00 10.00 5.00 6.00 8.00 6.00 22.00 12.00 2.00 20.00 20.00 20.00 9.00 32.00 10.00 3.00 28.00 28.00 30.00 13.00 45.00 12.00 4.00 31.00 31.00 35.00 4 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 9 DATE: 4/14/2011 T:\HASS\BOBF\I-FLY 2ND FLOOR.SDF JOB TITLE: I Fly 2nd Floor PAGE: B MATERIAL: THNWL HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVly BfyVly GatVly AlmChk DPV1v NPTee 2.157 6.00 12.00 3.00 14.00 8.00 1.00 12.00 12.00 12.00 3.260 10.00 20.00 7.00 22.00 14.00 1.00 18.00 18.00 20.00 4.260 13.00 26.00 8.00 29.00 16.00 3.00 26.00 26.00 26.00 PAGE: D MATERIAL: DIRON HWC: 140 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G N Ell Tee LngEll ChkVly BfyVly GatVly NPTee 8.390 31.00 59.00 22.00 76.00 20.00 7.00 59.00 DATE: 4/14/2011 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 10 T:\HASS\BOBF\I-FLY 2ND FLOOR.SDF JOB TITLE: I Fly 2nd Floor WATER SUPPLY ANALYSIS E a tyl0 •q oz ow oW ria 0 -ri 4J m 4) Available ri N ri O 0 0 • O N C V' ri CO4.0 0 o gC (9 W w r W v) U) oG W a u) -r-I 0 00 N 0 0 0 0 0 co 0 0 — N r-4 r -I 0 0 --C4. 0 rI O O E rd W 01 4,9 0 0 m N 0 0 411 0 0 N in 0 0 O> CO 0 0 l0 N 3 O a 4.. /< /7 / 8" CITY WATER MAIN TUKWILA PARKWAY (5. 1 58th STREET) M Z W cc EXISTING FDC - EXISTINGI POST / INDICATOR VALVE - w 04 LL CD 37-6' 25-0' / I 37-G. • O EXISTING MECHANICAL SPRINKLER ALARM 28.0 26'-0' 280. 26'-0' 2 n L n E<151:NG — INTERIOR DEM151NG WAL I BUILDING # 1 _ 27.05' FINISH FLOOR. O • DEW ICH 40 =AL I W z OZ EXISTING : INTERIOR DEMi51NG WALL 1! `C\ fi SITE PLAN SCALE: 1"=20' STAIR TOWER WITH STANDPIPE. BREAK ROOM `—WIDE FLANGE BEAM SUPPORTING 3" DEEP 18 GAGE PAN DECKING w/ RIGID INSULATION AND ROOFING ON TOP. WIDE FLANGE BEAM SUPPORTING 2" DEEP PAN DECKING w/ 3" OF CONCRETE ON TOP. 5" TOTAL THICKNESS., BUILDING SECTION SCALE: 4"=1'-0" 8X3-2 ,16 cv,cAu'va ,10 RISER LEGEND Bp EXISTING RISER DETAIL (Fp-, • 2r POITER-ROBAER 4065 HOSE VALVE 4065 HOSE VALVE 4X2-11 2" poi. WElDED ON. 4X4-6 ACCEPTED El Without Comments ar As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval, Final acceptance is st.41>pct to field test and inspection by The Tukwila Fire Prevention Bureau. TUKWILA FIRE DEPARTMENT Please call 206-575-4407 arid give this Fire Permit No. end exac.:: az!dress for shut- down or re,zZoraticn g_pprovaL (FP—) STANDPIPE DETAIL U.G. NOTES 1 THIS SITE PLAN IS FOR REFERENCE ONLY. SEE ARCHITECTURAL AND CIVIL DRAWINGS FOR ADDITIONAL SITE PLAN INFORMATION. 2 UNDERGROUND PIPING IS EXISTING. fLOW TEST STATIC RESIDUAL FLOW SOURCE LOCATION 120 20 13,000 CITY OF TUKWILA WATER SITE PAID MI -3 2011 e7z07 #3/2-7 NOTICE Weld stamps must be inspected before pipe is hung. Do not paint piping prior to hydrostatic test Da — 0313 e tizzza HANGER LEGEND A "U" HOOK B COACH SCREW ROD D BM. CLAMP W/ "STRAP E EYELET F HDI -P G CEILING FLANGE H SIDE BEAM BRACKET K SHORT CLIP M ALL THREAD ROD N TOGGLE NUT P POWDER DRIVEN STUD R EXPANSION BOLT S PIPE SPIKE T V Zi FITTING LEGEND P PIPE -0 -LET F PLAIN END FIT FITTING SN GROOVED SHAPED NIPPLE TSN THREADED SHAPED NIPPLE 4 - WAY EARTHQUAKE BRACE SPRINKLER LEGEND Y ex En x SPRINKLER ORIFICE SIZES I-- c., I— La LA 1,1 lip 1 4 32 SPRAY STATE CERTIFICATION TEMP RATING SPRINKLERS UP AND DOWN o _1 o Lal Lt.1 1116aEgli .. APPROVAL REQUIRED ugh Dect. SPRINKLER HEADS USED SYM MANUF MODEL TYPE THREAD SIZE ORIFICE SIZE I HEAD FINISH ESCUTCH I TEmp FINISH , Q;.y TOTAL XX QUALITY CONTROL BY Kevin Marr DATE 4/14/2011 APPROVED FOR FABRICATION BY DATE GENERAL NOTES 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL LISTED OR FM APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISERS AND DIMENSIONS SHOWN THUSLY (1-6) WHICH ARE END TO END. 3. EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPLICABLE EDITION 4. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPLICABLE EDITION. 5. PIPING SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPLICABLE EDITION 6. JOINING OF PIPE AND FITTINGS, THREADED & WELDED, SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPLICABLE EDITION. 7. OWNER TO PROVIDE ADEQUATE HEAT IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM TO PREVENT WATER IN PIPES FROM FREEZING. 8. ALL WIRING OF ELECTRICAL DEVICES (IF REQUIRED) TO BE PROVIDED BY OTHERS 9. PAINTING OF PIPE & EQUIPMENT (IF REQUIRED) TO BE PROVIDED BY OTHERS 10. FURRING OF PIPE & EQUIPMENT (IF REQUIRED) TO BE PROVIDED By OTHERS DESIGN CRITERIA PIPE NOTES REVISIONS NO DATE BY DESCRIPTION CONTRACT WITH: RUSHFORTH CONSTRUCTION CO. INC. 6012 12th STREET EAST STE 100 TACOMA, WA 98424 Phil Milianis PROJECT NAME: I -FLY INDOOR SKYDIVING TUKWILA, WA 98188 349 TUKVVILA PKWY 11-S-097 ATRI0T WWW.PATRIOTFIRE.COM RE 10. TEL (253) 926-2290 2707 70TH AVENUE EAST FAX (253) 922-6150 TACOMA, WA 98424 bobf@patriotfire.com DESIGNER Bob Forsberg SHEET FPI DATE April 12, 2011 OF 2 JOB NO. 11-1798 I ST g ( SeH- 40--BEIST f3" CH -140--`' o TO__ I LET r 1 U N it II '1 TOILET L i Istin 8 14X4-7 -9 0'-9' 1X3 - men's room 105 RETURN -AIR TOWER - REF DRAWINGS FOR -INTERNAL FE ER TO SKYVENTURE ATURES,AND FINISHES 01• riv 205 CLG 07x ,rr hallw; women's restroom 103 women's rest room 204 16'd (7.1BOD-AFFILI women's rest room 203 w' 110._: EXIST 6" COUNTER — s _0_ EXIST 4" SCH 40 _r EXIST 6" SCH 40 EXIST 3" SCH 40 SDI 8 HYDRAULIC REMOTE AREA THIS 1500 SQ. FT. AREA HAS BEEN HYDRAULICALLY CALC A DENSITY OF .15 GPM/SQ FT. SYSTEM DEMAND 478.4 74.4 PSI AT THE BASE OF RISER, NODE 1. V ; 2 10- I; UP wIl`I entry=', lobby X7)_0' 6 _, "'�F r<, 1 4 14X1-8 2- ,, 1-1-6 6'-0' BOD-AFF11-1 W8 X 8X24. EXISTING INTERIOR DEMISING WALL 14 12-0 9-863'-`[' Q`unit server room 114 5-10i--Utl.li'Ky 8-11 work station -�r DRAWINGS FOR INTERNAL FEATS -AND FINISHESj RETURN 1RJOWER - REFER TO SK) J NTURE ;DRAWINGS FOR INTE'NAL FEATURES -AND FINISHES __RETURN AIR TOWER - REFER TO SKYV N URE • r O RISER LEGEND 1 EXISTING 8" GRINNELL MODEL A ALARM VALVE 8X3-2 0 O O V r 'G . j EXISTING RISER DETAIL SCALE: 1/8"=1'-0" TOLCO FIG 75 45' /—e ATR PER PLAN WEDGE ANCHOR AT 1ST FLOOR SAMMY X -PRESS 20 AT 2ND FLOOR s ATR PER PLAN RING HANGER w/ SURGE RESTRAINT CLIP END OF LINE RESTRAINT FIRST FLOOR PLAN 2" DEEP 20 GAGE PAN DECK WITH 3" OF CONCRETE ON TOP AT FOR 2ND FLOOR DECK. 5" TOTAL THICKNESS. 3" DEEP 18 GAGE PAN DECK AT LOWER ROOF DECK. SCALE: 1/8" =1'-0" WIDE FLANGE BEAM PER PLAN. TOLCO FIG 825 TO BUILDING TO BUILDING STRUCTURE. TOLCO FIG 980 EQ. END. 45-60' FROM VERTICAL TOLCO FIG 4L TO PIPE. LONGITUDNAL EQ BRACE NTS GENERAL NOTES SECOND FLOOR PLAN SCALE: 1/8"=1'-0" 1 TYPICAL 1st FLOOR HANGER TO BE KWIK BOLT, ROD COUPLING, ATR AND RING. 2 TYPICAL 2nd FLOOR HANGER TO SAMMY X -PRESS OR BEAM CLAMP, ATR AND RING HANGER. 3 ALL WELDED PIPE TO BE IMPRESSION STAMPED. WIDE FLANGE BEAM PER PLAN. TOLCO FIG 825 TO BUILDING TO BUILDING STRUCTURE. TOLCO FIG 980 EQ. END. 45'-60' FROM VERTICAL TOLCO FIG 1001 TO PIPE. LATTERAL EQ BRACE NTS Ntk JLATED TO QPM @ HANGER LEGEND A "U" HOOK B COACH SCREW ROD D BM. CLAMP W/ "STRAP E EYELET F HDI -P G CEILING FLANGE H SIDE BEAM BRACKET K SHORT CLIP M ALL THREAD ROD N TOGGLE NUT P POWDER DRIVEN STUD R EXPANSION BOLT S PIPE SPIKE T U V W X SAMMY X -PRESS XP 20 Y z FITTING LEGEND P PIPE -0 -LET F PLAIN END FIT FITTING SN GROOVED SHAPED NIPPLE TSN THREADED SHAPED NIPPLE 2 - WAY EARTHQUAKE BRACE WAY EARTHQUAKE BRACE 4 - }D STRUCTUREINEOF PIPE IN TO CEINCHNTER LES SPRINKLER LEGEND Ct N CI Y CO SPRINKLER ORIFICE SIZES AND TYPE = o Fc El. i o a W N ~ rn 1 5 3 7 1 0 0 1/2" 2 16 8 16 2 SPRAY QO1" 3 17 ❑ ® 3/4" 4 32 SPRAY O 1" 1 3 7 1 Q a 1/2" 2 8 16 2 SIDEWALL Q 1" 1" DRY TYPE O 0 1" 2 OO 1" STATE TEMP RATING SPRINKLERS UP AND DOWN Z OPENING N : : N UP m =3 Z0 :EU:IC:ION j,T 1�' er 8 ftaberw ; 397 > -64'24 in}�� A `,ti- 0 0 165° m >- o 0 O 212° ® 1" Q 286'1"®1/2" 350 °1" 1" 500° 0 1/2" APPROVAL REQUIRED CITY OF TUKWILA SPRINKLER HEADS USED SYM MANUF MODEL TYPE THREAD SIZE ORIFICE SIZE HEAD FINISH ESCUTCH FINISH TEMP QTY O RELIABLE F1FR UPRIGHT 1 5.6K BRONZE - 155' 69 o RELIABLE F1 FR PENDENT 2' 5.6K CHROME CHROME 155' ® RELIABLE F1FR PENDENT z 5.6K CHROME 401 2PC 155 V RELIABLE F1 FR HSSW s 5.6K BRONZE - 155' 1 TOTAL 85 QUALITY CONTROL BY Kevin Marr DATE 4/14/201 1 APPROVED FOR FABRICATION BY DATE GENERAL NOTES 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT SHOWN THUSLY (1-6) WHICH ARE END TO END. 3. EARTHQUAKE BRACING SHALL BE PROVIDED IN NFPA PAMPHLET NO. 13, APPUCABLE EDITION 4. PIPE HANGERS AND METHOD OF HANGING TO BE NFPA PAMPHLET NO. 13, APPLICABLE EDITION. 5. PIPING SHALL BE IN ACCORDANCE WITH NFPA 6. JOINING OF PIPE AND FITTINGS, THREADED & WITH NFPA PAMPHLET NO. 13, APPLICABLE EDITION. 7. OWNER TO PROVIDE ADEQUATE HEAT IN AREAS SYSTEM TO PREVENT WATER IN PIPES FROM FREEZING. 8. ALL WIRING OF ELECTRICAL DEVICES (IF REQUIRED) BY OTHERS UL LISTED OR FM APPROVED. RISERS AND DIMENSIONS ACCORDANCE WITH IN ACCORDANCE WITH PAMPHLET NO. 13, APPUCABLE EDITION WELDED, SHALL BE IN ACCORDANCE PROTECTED BY A WET PIPE SPRINKLER TO BE PROVIDED 9. PAINTING OF PIPE & EQUIPMENT (IF REQUIRED) BY OTHERS TO BE PROVIDED 10. FURRING OF PIPE & EQUIPMENT (IF REQUIRED) BY OTHERS TO BE PROVIDED DESIGN CRITERIA 1 DESIGNED PER NFPA 13, 2010 2 ORDINARY HAZARD. EDITION. PIPE NOTES 1 ALL THREADED PIPE TO BE SCH 2 ALL WELDED PIPE TO BE SCH 10. 3 ALL WELDED PIPE TO BE IMPRESSION 40. STAMPED. REVISIONS NO DATE BY DESCRIPTION - 4/27/201 1 BF REVISED PER 3rd PARTY REVIEW COMMENTS CONTRACT WITH: RUSHFORTH CONSTRUCTION 6012 12th STREET EAST STE 100 TACOMA, WA 98424 Phil Milianis CO. INC. PROJECT NAME: I—FLY INDOR 31 y • e+ TU KWILAYDIVING TUKWILA, WA //--- s -o'7 PARKWAY 98188 _ (-z-) ATRIOPATRIFP099CF WWW.PATRIOTFIRE.COM 2707 70TH AVENUE EAST TACOMA, WA 98424 TEL 926-2290 FAX (2533 922-6150 bobf@patriotfire.com DESIGNER Bob Forsberg SHEET F P 2 DATE April 12, 2011 21 OF 2 JOB NO. 11-1798 t