Loading...
HomeMy WebLinkAboutPP - 14415 45TH LN S - UNKNOWN - PERMITS AND PLANS14415 45TH LN S ASSOCIATED PERMITS 18-5-066 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 14415 45th Lane S Suite Number: Floor: Tenant Name: (new construction) New Tenant? ❑ - Yes Q - No Property Owner's Name: Cary Lang Construction 004000-0398 Mailing Address: 29815 24th Ave SW CONTACT PERSON -if there are questions about the submittal. Name: Jake Box Company Name: Glacier Fire Protection, LLC Federal Way WA 98023 City State Zip Day Telephone: (307) 251-1701 Mailing Address: PO Box 7980 Bonney Lake jakeb@glacierfp.com City E-mail Address: WA 98391 State Zip Fax Number: N/A Erin Clayton 7544-0817-C Contractor's City of Tukwila 0998044 NICET III number: Business License number: Total number of new/relocated devices or sprinkler heads: 32 Valuation of Project (contractor's bid price): $ 7,800.00 Scope of Work (please provide detailed information): Design & install fire sprinkler system in new constructed 1 family dwelling per NFPA 13D. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE ' AUTHORIZED AGENT: Signature: Print Name: Plan Permit App.doc Date: 3/26/2018 Day Telephone: (307) 251-1701 8/22/14 TFD FP Form 8 SITE PLAN 0 4 8 16 32 SCALE 1/16"=1'-0" GENERAL NOTES SCOPE OF WORK z PROPERTY LINE GLACIER FIRE PROTECT ON, LLC TO START AT 1 112" BACKFLOW 14415 45TH LANE SOUTH NEW 1" WATER METER �® BY OTHERS INSTALLEDLBY OTHERS NEW 1 112" UG CPVC PIPE STRAP / AFCON MODEL 510 CPVC PIPE/ HEX HEAD SELF TAPPING SCREW AFCON #905 DOUBLE FASTENER CPVC PIPE STRAP TYPICAL HANGER DETAIL #1 SCALE : N.T.S. BY OTHERS O Without Comments As Noted in Red O Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau f(v conformance wits, current City standards. Acceptao e is subject to errors and omissions which do not authorize vtola ions of adopted standards and ordin oc4e4;. The resp r5i011ici tor the adequacy of design 4e s totally with the 1deslgner. Additions, delet1oE ; ,;..rovisions to these drawings after this date will void tr1 :..-c';c:otance and wig require a resubmit r, 3 r .vi ::7 .5;fi os for Stitn•r:3cuent: approval. Final accep !y:. is sl ro, is i.;: field test and Inspection by The Tukwila r, �,d eau. Date: /- tX l� e4t-i'o -r we -e104+-it- ‘-e i 7'- (.Iy dro a re ve 1. EJot, CJ ej rev'vel. TUKWILA FIRE, DEPARTMENT Please call 206-575-4<07y�and give Ger t its Fire 1.:' ::i�niit No. l �S-off and exact addra:s for shut- down hutdown or Il r on app ovol, WOOD LAG SCREW \ // AFCON #514 HANGER I CPVC SPRINKLER PIPE WOOD STRUCTURE TYPICAL HANGER DETAIL #2 SCALE : N.T.S. L /HANGER APPLICATION SOUTH 144TH ST NEW CITY CONNECTION j BY OTHERS RESTRAINER APPLICATION HEX SCREW HEAD SELF SINGLE FASTENER CPVC PIPE STRAP TYPICAL HANGER DETAIL #3 SCALE : N.T.S. 1. THE FIRE PROTECTION SPRINKLER SYSTEM FOR THE SINGLE FAMILY DWELLING UNIT SHALL BE DESIGNED AND INSTALLED PER NFPA 13D, 2013. 2. CALCULATION FOR THE RESIDENCE SHALL BE PER NFPA 13D, 2013. 3. PIPE THROUGHOUT THE DWELLING UNIT TO BE CPVC SPRINKLER PIPING UNLESS NOTED OTHERWISE. 4. ALL HANGERS SHALL BE PLACED AND INSTALLED IN ACCORDANCE WITH NFPA 13, 2013. 5. SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 SQ.FT. AND LESS. 6. SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES THAT ARE LESS THEN 24 SQ.FT., THE LEAST DIMENSION DOES NOT EXCEED 3'-0 AND THE ROOM IS SURFACED WITH NONCOMBUSTIBLE OR LIMITED COMBUSTIBLE MATERIALS. 7. SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES, OPEN ATTACHED PORCHES, CARPORTS, AND SIMILAR STRUCTURES. 8. SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS, CONCEALED SPACES, FLOOR/CEILING SPACES, CRAWL SPACES, AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING PURPOSES AND DO NOT CONTAIN FUEL -FIRED EQUIPMENT. 9. WIRING OF ANY NEW DEVICES IF REQUIRED IS BY OTHERS. 10. PAINTING AND LABELING OF PIPING IF REQUIRED IS BY OTHERS. FIRE SPRINKLERS SHALL NOT BE PAINTED OVER. 11. IT SHALL BE THE OWNERS RESPONSIBILITY TO MAINTAIN THE TEMPERATURE ABOVE 40° AT ALL TIMES. 12. A MAIN DRAIN IS TO BE PROVIDED AND INSTALLED IN ACCORDANCE WITH NFPA-13D. HUB DRAINS TO BE PROVIDED BY OTHERS AS NEEDED. 13. NO GYP. BD. CEILINGS SHALL BE INSTALLED UNTIL ROUGH VISUAL INSPECTION IS COMPLETE. 14. MAXIMUM RESIDENTIAL PENDANT SPRINKLER SPACING COVERAGE 16'-0 x 16'-0. MAXIMUM DRY SIDEWALL SPRINKLER HEAD SPACING 14'-0 X 14'-0. 15. MINIMUM RESIDENTIAL PENDANT SPRINKLER SPACING 8'-0 O.C. MINIMUM DRY SIDEWALL SPRINKLER SPACING 6'-0 O.C. 16. ALL VALVES TO BE LABELED IN ACCORDANCE WITH NFPA-13D. 17. PIPE SHALL BE REQUIRED TO REMAIN ON A 2.25" CENTERLINE ON THE TOP OF THE BOTTOM TRUSS CORD ALLOWING FOR TENTING AND SHALL HAVE PRIORITY OVER OTHER TRADES. GLACIER FIRE PROTECTION WILL PROVIDE ONE WET PIPE AUTOMATIC SPRINKLER SYSTEM TO PROTECT THE NEW RESIDENCE. EXCLUSIONS PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT ELECTRICAL WIRING OF ANY KIND INCLUDING BUT NOT LIMITED TO WATERFLOW SWITCH, ELECTRIC BELL, AND TAMPER SWITCHES CENTRAL STATION MONITORING EQUIPMENT, WIRING AND SERVICES CEILING AND WALL REMOVAL/REPLACE TO FACILITATE THE INSTALLATION OF THE SPRINKLER SYSTEM. UNDERGROUND WORK OF ANY KIND DESIGN CRITERIA PER NFPA 13D (2016) RM -01 (RESIDENCE) THE DENSITY SHALL BE 13 GPM/SF OVER THE MOST REMOTE 2 SPRINKLERS WITHIN A COMPARTMENT 16'-0 x 16'••0 MAX SPACING Sprinkler Legend Temper4ture l 155°F ' J 175°F ' 1 IMMININ u_ '- Nto u- Finish a) :e White White Chrome Response Y U .B O !Quick Quick Quick G) N (f)) ;*g!C \ \ ',-- Type Pendent Pendent' 1Sidewall 1 3 a) (. L ,0 0 crI co Lf) a) V •t 4 4.41 Quantity N T N Total = 33 Model RFC 581 RFC49 ( W It u } o wo- co u_ z.- (/) co co Q It r - i'x' ) Q' RA5231 Manufacturer Reliable If ca .) ct Reliable a) m .Q) cc (Symbol yY}f' T WATER FLOW INFORMATION NORTH FIRE SPRINKLER RISER WATER GAUGE 314" DRAIN DOMESTIC LINE BY OTHERS 11 ri..,•c'; MAINTAIN 2" ANNULAR __ CLEARANCE AROUND PIPE WATER FLOW SWITCH -1 112" x 1" REDUCER GLACIER FIRE PROTECTION, LLC TO START WORK HERE 1 112" AMES 2000B BACKFLOW PREVENTOR PROVIDED AND INSTALLED BY OTHERS 1 112" WATER ENTRY BY OTHERS _'TIiTI 11111 III 1.1 -_ilr 1l: III _ - -III-I i- WATER FLOW INFORMATION HAS BEEN PROVIDED BY WATER DISTRICT 125 STATIC: 66 PSI RESIDUAL: 20 PSI FLOW: 1700 GPM DRAWING INDEX GLACIER FIRE PROTECTION LLC PO BOX 7980 BONNEY LAKE, WA 98391 P: (253) 501-7558 www.glacierfireprotection.com GLACIFP834MJ FP 0.10 FP 2.10 SITE PLAN AND NOTES MAIN LEVEL & UPPER LEVEL PLAN PARCEL # 004000-0398 WASIB$G T1 Si A1I QIEf1TIFICATE OF CE II`Its I FIRE PROTECTION SPRU4Rt.E#I Erin Clayton 7544-0817-C Level3 Glacier Fire Protection, L.L.C. GLACIFP834MJ 03/22/2018 Date 8CY Y$UMS r 1 1 1 1 1 1 VICINITY MAP 41- 46: 4JO J rei PAID i ?AR 2 2t 1 1KWILA FIRE co co C� Q 5 SITE PLAN AND NOTES SPRINKLER PLAN 0 2 4 6 8 10 12 SCALE: 1/16" = 1'-0" DRAWN BY: SFC REVISIONS NO. DESCRIPTION 0 A DATE: 03/28/18 CONTRACT #: 40032 FLOOR / AREA SITE PLAN AND NOTES SHEET NUMBER FP 0.10 1 of 2 / 5'-1 • GREAT ROOM 9`-0 A.F.F. 2'-1 5'-1 • • / DINING ROOM 9'-0 A.F.F. OPEN TO ABOVE 3'-1 / ENTRY 9'-0 A.F.F. COVERED PORCH MAIN LEVEL PLAN SCALE : 1/4" = 1'-0 / / 8'-0 7'-41/2 COVERED PATIO NOOK 9'-0 A.F.F. 0 8'-0 yv•vv y/yv/vv;yy'yo 3'-71/ 1 \ 1 2'-5'/ C0 • GARAGE / • / KITCHEN 9'-Q A.F.F. / 8'-0 STUDY 9'-0 A.F.F. 1'- r 3'-91/2 1 40'-0 !GLACIER FIRE PROTECTION, LLC 70 START © BACKFLOW PREVENT PPROX. 4'-0 A.F.F. HANGER SPACING LEGEND NOMINAL PIPE SIZE (IN.) 3/4" 1" 1 114" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" STEEL PIPE SCH 40, SCH 10, DF,EF N/A 12-0 12-0 15-0 15-0 15-0 15-0 15-0 15-0 15-0 THREADED LIGHTWALL N/A 12-0 12-0 12-0 12-0 12-0 N/A N/A N/A N/A COPPER 8-0 8-0 10-0 10-0 12-0 12-0 12-0 15-0 15-0 15-0 CPVC 5-6 6-0 6-6 7-0 8-0 9-0 10-0 N/A N/A N/A PER NFPA 13 9.2.2.1 (A) 1 0'-6' 4 3'-0 \\ / 1 0'-8 MASTER BEDROOM VAULTED CEILING BEDROOM 2 8'-0 A.F.F. 1 10'-4'/ 1• r 0'-51 2'-8'/ \\ \\\\\\\\\'\\>\ / 8'-0 \ MASTER •BATH 8'-0 AF.F. Q h, i CLOSET 8'-0 A.F.F. 6'-0 0 0 co OPEN TO BELOW 5'-1 0 _\ \ \` UTILITY 8'-0 A.F.F. BEDROOM 3 8'-0 A.F.F. �\\\\\ \\ BATH 8'-0 A.F.F. 1 1 0'-4144 to M BEDRO.OM..4___ VAULTED CELING 1 0'-41/ M - 0 1 0'-4'/2 r o PLAYROOM Co 8'-O A.F.F. dentia1°O.O5Ogprr/ft2 for 9OO.00ft2 REMOTE AREA UPPER LEVEL PLAN SCALE :1/4" = 1'-0 1 _.. / 0 Hydraulic Information Remote Area 1 OCCUPANCY CLASSIFICATION Residential DENSITY 0.050gpmift2 for 900.0082 (Actual 261.6082) TOTAL HEADS FLOWING 2 K -FACTOR 4.9 TOTAL WATER REQUIRED 276.33 TOTAL PRESSURE REQUIRED 46.123 BASE of RISER (gpm) 276.33 BASE of RISER (psi) 46.123 SAFETY MARGIN (psi) +18.281 (28.4%) ARMOVER/DROP DROP DETAI LS SCALE : N.T.S. PIPE SHALL BE REQUIRED TO REMAIN ON A 2.25" CENTERLINE ON THE TOP OF THE BOTTOM TRUSS CORDALLOWING FOR TENTING AND SHALL HAVE PRIORITY OVER OTHER TRADES. ADEQUATE INSULATION BY OTHERS O SPRAY RIGID / FOAM INSULATION / BY OTHERS I(– I ll If-- II II - 1 1 I� 200 DEGREE SIDE OF OPEN OR RECESSED FIRE PLACE 36 in 12 in FRONT OF RECESSED FIREPLACE 60 in 36 in COAL -OR WOOD BURNING STOVE 42 in 121n KITCHEN RANGE 18 in 9 in WALL OVEN <7\20 </X/x. , / ,/''x'-'/")`/\• .!',/ X \< \,/.. \ix/ / .\ :'� y \ .>-, /� k... 1>( .• I' " is � ���� • CPVC \ NO -BLOCK FASTENER48 Nur V . , / ..4)4"ii/AV ,, PIPE / \ / 41.�♦� s #. 18 in TJI JOIST UNINSULATED HOT WATER PIPES 12 in 6 in SIDE OF CEILING OR WALL MOUNTED HOT AIR DIFFUSERS 24 in 12 in FRONT OF WALL MOUNTED HOT AIR DIFFUSERS 36 in 18 in C HOT WATER HEATER OR FURNACE PIPE TENT INSULATION DETAIL #1 SCALE : N.T.S. BLOWN -IN INSULATION ABOVE BATT INSULATION BY OTHERS BATT TYPE INSULATION COLD SPACE , ///,,/,// ///, /////.// ,/,/ //,/ /////, TUU ' Lsbr It It tip It It //%' / ; // r��� p / ; / / / '/ / / . / / / // / / /// /// / / /. / / C\) SPRINKLER PIPE VAPOR BARRIER /// // /// // // //. /// TRUSS CHORD OR JOIST GYPSUM BOARD CEILING PIPE TENT INSULATION DETAIL #2 SCALE : N.T.S. STAND OFF HANGER #10x1" HEX HEAD CAP SCREW COMPOSITE WOOD I -JOIST INSUALTION BY OTHERS VAPOR BARRIER STAPLED 10d NAIL (TYP.) WOOD BLOCKING GYP.BOARD/T&G CEILING TJI SPACE \\— SEMI-REC. PENDENT SPRINKLER PIPE TENT INSULATION DETAIL #3 SCALE : N.T.S. MINIMUM DISTANCES FOR TEMPERATURE RESIDENTIAL SPRINKLERS HEAT SOURCE 165 DEGREE 200 DEGREE SIDE OF OPEN OR RECESSED FIRE PLACE 36 in 12 in FRONT OF RECESSED FIREPLACE 60 in 36 in COAL -OR WOOD BURNING STOVE 42 in 121n KITCHEN RANGE 18 in 9 in WALL OVEN 18 in 9 in HOT AIR FLUES 18 in 9 in UNINSULATED HEAT DUCTS 18 in 9 in UNINSULATED HOT WATER PIPES 12 in 6 in SIDE OF CEILING OR WALL MOUNTED HOT AIR DIFFUSERS 24 in 12 in FRONT OF WALL MOUNTED HOT AIR DIFFUSERS 36 in 18 in C HOT WATER HEATER OR FURNACE 6 in 3 in LIGHT FIXTURE OW -250W 6 in 3 in PER NFPA 13D TABLE 7.5.5.3 AT CERTIFICAT ap I OMPAE 1 FIRE PROTECI10/41S PR • I Erin Clayton 7544-0317-C Level 3 Glacier Fire Protection, L.L.C. GLACIFP834MJ 03/2212018 Y E►sitq 1t2/St11 8 Sprinkler Legend IL 0 1 t N ii 0) N a) :L' 0) E 2 U N O N N v . . U U O 8 U O v) c1. Ha 4- 0) a) CL in 0 ti co I0 rn rn N C� Q) -a O 0,0 LL F3RES44 DRY M tD cc M tO M Manufacturer a) .n a a) a) a a) T NORTH GLACIER FIRE PROTECTION LLC PO BOX 7980 BONNEY LAKE, WA 98391 P: (253) 501-7558 www.glacierfireprotection.com GLACIFP834MJ PARCEL # 004000-0398 co O r co Lo Nr ~ MAIN LEVEL PLAN SPRINKLER PLAN 0 2 4 6 8 10 12 SCALE: 1/4" = 1'-0" DRAWN BY: SFC REVISIONS NO. DESCRIPTION / 1 \ CITY APPROVAL /2\ DATE: 03/28/18 CONTRACT #: 40032 FLOOR /AREA MAIN LEVEL PLAN SHEET NUMBER FP 2.10 2 of 2