HomeMy WebLinkAboutPP - 12566 50TH AVE S - CARY LANG CONSTRUCTION / CODIGO LOT 5 - PERMITS AND PLANS12566 50TH AVE S ASSOCIATED PERMITS 19-5-109 SITE PLAN NEW CITY CONNECTION __-- BY OTHERS ka ❑ Without Comments As Noted in Red. ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for c.onformance wan current City standards. Acce,r.°. IF, subject to errors and omissions which ,violations of adopted :tandards and or « 5rY - The resporsinllity for the adequacy of dell, (orally with the designer. Additions, delet. os R 1 Mvisions to these; drawings afte, this date will vo;d a I s i, r prance and Mil require a resubmittal of revised drawing, for subsequent approval. Final acceptance is subject to deJd test and inspection by The Tukwila Flee Prevention Bureau, Date: S - 19 By: CPVC PIPE' \ si cbser NEW 1" WATER METER .......................................................... RV OTHERS \ l - GLACIER FIRE PROTECTION, LLC \TO START AT 1112" BACKFLOW V-10" AFF \120V 6* BEL BY OTHERS N� 1414,„ ►'ry�`A.•�`_ plow Cb,,1-) +4-- vre flj;Q J L A FIRE? DEPARTMENT Please call 206-575-4407 and give this Fire Permit rmit No. S- and exact • ddress for shut- down or restoration approv 1. CPVC PIPE 'STRAP 1 AFCON MODEL 510 (HEX HEAD SELF !TAPPING SCREW AFCON #905 DOUBLE FASTENER CPVC PIPE STRAP TYPICAL HANGER DETAIL #1 SCALE : N.T.S. WOOD LAG SCREW AFCON #514 HANGER r.. CPVC SPRINKLER PIPE WOOD STRUCTURE TYPICAL HANGER DETAIL #2 SCALE: N.T.S. (.HANGER APPLICATION 1 HEX HEAD SELF TAPPING SCREW C.7 j RESTRAINER APPLICATION CPVC PIPE SINGLE FASTENER CPVC PIPE STRAP TYPICAL HANGER DETAIL #3 SCALE : N.T.S. GENERAL NOTES 1. THE FIRE PROTECTION SPRINKLER SYSTEM FOR THE SINGLE FAMILY DWELLING UNIT SHALL BE DESIGNED AND INSTALLED PER NEPA 13D, 2013. 2. CALCULATION FOR THE RESIDENCE SHALL BE PER NEPA 13D, 2013. 3. PIPE THROUGHOUT THE DWELLING UNIT TO BE CPVC SPRINKLER PIPING UNLESS NOTED OTHERWISE. 4. ALL HANGERS SHALL BE PLACED AND INSTALLED IN ACCORDANCE WITH NFPA 13, 2013. 5. SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 SQ.FT AND LESS. 6. SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES THAT ARE LESS THEN 24 SQ.FT., THE LEAST DIMENSION DOES NOT EXCEED 3`-0 AND THE ROOM IS SURFACED WITH NONCOMBUSTIBLE OR LIMITED COMBUSTIBLE MATERIALS. 7. SPRINKLERS SHALL Nor BE REQUIRED IN GARAGES, OPEN ATTACHED PORCHES, CARPORTS, AND SIMILAR STRUCTURES. 8. SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS, CONCEALED SPACES, FLOOR/CEILING SPACES, CRAWL SPACES, AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING PURPOSES AND JO NOT CONTAIN FUEL -FIRED EQUIPMENT 9. WIRING OF ANY NEW DEVICES IF REQUIRED IS BY OTHERS. 10. PAINTING AND LABELING OF PIPING IF REQUIRED IS BY OTHERS. FIRE SPRINKLERS SHALL NOT BE PAINTED OVER. 11. IT SHALL BE THE OWNERS RESPONSIBILITY TO MAINTAIN THE TEMPERATURE ABOVE 40° AT ALL TIMES. 12. A MAIN DRAIN IS TO BE PROVIDED AND INSTALLED IN ACCORDANCE WITH NFPA-13D. HUB DRAINS TO BE PROVIDED BY OTHERS AS NEEDED. 13. NO GYP. BD. CEILINGS SHALL BE INSTALLED UNTIL ROUGH VISUAL INSPECTION IS COMPLETE. 14. MAXIMUM RESIDENTIAL PENDANT SPRINKLER SPACING COVERAGE 16'-0 x 16'-0. MAXIMUM DRY SIDEWALL SPRINKLER HEAD SPACING W-0 X 14'-0. MAXIMUM RESIDENTIAL DRY SIDEWALL SPRINKLER HEAD SPACING 16-0 X 20`-0. 15. MINIMUM RESIDENTIAL PENDANT SPRINKLER SPACING 8'-0 O.C. MINIMUM DRY SIDEWALL SPRINKLER SPACING 6'-0 0.0, MINIMUM RESIDENTIAL DRY SIDEWALL SPRINKLER SPACING 8`-0 0.0. 16 AI 1 VAI VPS TO SF I AAFR Fr) IN AC;CC)RDANCF WITH NFPA-13r 17. PIPE SHALL BE REQUIRED TO REMAIN ON A 2,25" CENTERLINE ON THE TOP OF THE BOTTOM TRUSS CORD ALLOWING FOR TENTING AND SHALL HAVE PRIORITY OVER DTHER TRADES. SCOPE OF WORK GLACIER FIRE PROTECTION WILL PROVIDE ONE WET PIPE AUTOMATIC SPRINKLER SYSTEM TO PROTECT THE NEW RESIDE VCE. EXCLUSIONS PAINTING OR LABELING OF PIPE ANDIOR EQUIPMENT ELECTRICAL WRING OF ANY KIND INCLUDING BUT NOT LIMITED TO WATERFLOW SWITCH, ELECTRIC BELL; AND TAMPER SWITCHES CENTRAL STATION MONITORING EQUIPMENT WIRING AND SERVICES CEILING AND WALL REMOVAL/REPLACE 10 FACILITATE THE INSTALLATION OF THE SPRINKLER SYSTEM. UNDERGROJND WORK OF ANY KIND DESIGN CRITERIA PER NFPA 13D (2016) RM -01 (RESDENCE) THE DENSITY SHALL BE 13 GPM/SF OVER THE MOST REMOTE 2 SPRINKLERS WITHIN A COMPARTMENT. 16-0 x 16'-a MAX SPACING WATER FLOW INFORMATION Sprinkler Legend 5.8; Pendent FIRE SPRINKLER RISER WATER GAUGE ...... 1" DRAIN DOMESTIC LINE BY OTHERS - GLACIER FIRE PROTECTION, LLC TO START WORK HERE 1"AMES 20008 BACKFLOW PREVENTOR PROVIDED AND INSTALLED BY GLACIER FIRE PROTECTION, LLC - -1112" WATER ENTRY BYOTHERS MAINTAIN 2" ANNULAR ......... CLEARANCE AROUND PIPE 125: wr, WATER FLOW INFORMATION HAS BEEN PROVIDED BY TUKWLLA PUBLIC WORKS DEPARTMENT STATIC: 148 PSI RESIDUAL: 20 FSI FLOW: 4910 GPM DRAWING INDEX FP 0.10 FP 2.10 SITE PLAN AND NOTES MAIN AND UPPER LEVEL PLAN GLACIER FIRE PROTECTION LLC PO BOX 7980 BONNEY LAKE, WA 98391 (253) 501-7558 mins,Glacierfireprote0on.com GLACIFP834MJ PARCEL "# 017900-2501 Plitt P1� OT ECUO$ txt' 1 ErinClayton 7544-0817-C' Level 3 Glacier Flre Protection, t. L. C. GLACIFP834MJ t::...-....; 08130/2018 VICINITY AP 0 2 4 6: 8' 10 SCALE: 1/16" =1'-0" DRAWN BY: SEC REVISIONS DESCRIPTION CONTRACT #: 40059 FLOOR /AREA SITE PLAN AND NOTES SHEET NUMBER 1 II I 0 BAT 616h/ BEDROOM 5 8'-0 7LOF1 3'-63/4 1' #r\ 4'4/ f=== weP CP 1 BEDROOM 4 12I-11% T-5% 6'-1% 4'41% \ 8'-0 0'-6 7'-6 BEDROOM 3 4'-0 REMOTE AREA 1 MASTER SUITE <10 17 7 • UPPER LEVEL PLAN SCALE 1/41" = 11-0 • Hydraulic Information NOMINAL FIFE SIZE (IN.) Remote Area 1 OCCUPANCY CLASSIFICATION ' 1 1/4" Resicential DENSITY 2 1/2" 0.050gpm/ft2 for 900.00ft2 (Actual 243.58ft2) TOTAL HEADS FLOWING 6" 2 K -FACTOR N/A 4.9 TOTALWATER REQUIRED 16-0 26.34 TOTAL PRESSURE REQUIRED 15-0 42.722 BASE of RISER (gpm) 15-0 26.34 BASE of RISER (psi) 12-0 42.722 SAFETY MARGIN (pi) 12-0 4106.279 (71.1%) - - PNTRY L.)) 4'-0 31-614 DEN EF 8'-0 LIVING ROOM .6) KITCHEN DINING ROOM 77, 1 1 13'-4 2'-3 PDW 1 J.H akMUDROOIVI, 1 1' 81/4 .1( MAIN LEVEL PLAN SCALE : 1/4" = 11-0 , ARVIOVER / DROP \ DROP— DETAILS SCALE : N.T.S. HANGER SPACING LEGEND NOMINAL FIFE SIZE (IN.) 3/4" 1" ' 1 1/4" 1 1/2" 2 2 1/2" 3" 4" 6" 8" STEEL PIPE SCH 40, SCH 10, DEEF N/A 12-0 12-0 16-0 16-0 15-0 15-0 15-0 16-0 15-0 THREADED LIGHTWALL N/A 12-0 12-0 12-0 12-0 12-0 N/A NIA N/A N/A COPPER 8-0 8-0 10-0 10-0 12-0 12-0 12-0 Al 15-0 15-0 I 15-0 CPVC 5-6 6-0 6-6 7-0 8-0 9-0 10-0 NIA N/A N/A PER NFPA 13 9.2.2.1 (A) MINIMUM DISTANCES FOR TEMPERATURE RESIDENTIAL SPRINKLERS HEAT SOURCE 165 DEGREE 200 DEGREE - SIDE OF OPEN OR RECESSED FIRE PLACE FRONT QF RECESSED FIREPLACE COAL.OR W000 BURNING STOVE 36 in KITCHEN RANGE WALL OVEN HOT AIR FLUES UNINSULATED HEAT DUCTS UNINSULATED HOT WATER PIPES SIDE OF CEILING OR WALL MOUNTED HOT AIR DIFFUSERS FRONT OF WALL MOUNTED HOT MR DIFFUSERS T HOT WATER HEATER OR FURNACE LIGHT FIXTURE OW -250W PER NFPA 130 TABLE 7.5.5.3 60 in 42 in 18 in 18 in 18 in 18 in 12 in 36 in 12 in 24 in 36 in 12 in 9 in 9 in 91n 9 in 6 in 12 in 18 in 6 in 3n 6 in 3n STAND OFF HANGER #10x1" HEX HEAD CAP SCREW COMPOSITE WOOD I -JOIST GYP. BOARD/ T&G CEILING INSUALTION BY OTHERS VAPOR BARRIER STAPLED - 10d NAIL (TYR) WOOD BLOCKING TJI SPACE SEMI-REC. PENDENT SPRINKLER PIPE TENT INSULATION DETAIL #3 SCALE N.T.S. BLOWN -IN INSULATION ABOVE BATT INSULATION V OTHERS BAT- TYPE INSULATION COLD SPACE ....• • .• • • . • ••• „ „. • u uUu• 0 O• . ..• "", "vAnpon .• „ ••••• • • n r)(-, r). ...• .„... U U Li • ....• „ BARRIER 1 SPRINKLER PIPE TRUSS CHCRD OR JOIST 1 GYPSUM BOARD CEILING PIPE TENT INSULATION DETAIL #2 SCALE : N.T.S. • SPRAY RIGID / FOAM INSULATION / BY OTHERS • • • PIPE SHALL BE REQUIRED TO REMAIN ONA 2.25" CENTERLINE ON THE TOP OF THE BOTTOM TRUSS CORD ALLOWING FOR TENTING AND SHALL HAVE PRIORITY OVER OTHER TRADES. ADEQUATE INSULATION BY OTHERS •• PV( PIPE PIPE • TJI JOIST 11 ............... - .... PIPE TENT INSULATION DETAIL #1 SCALE :N.T.S. WASHINGTON STATE ORGFIFICATIE OF COMPETENCY nom PROTECTION Si'IGNIMER SYRTIS Erin Clayton 7544-0817-C Level 3 Glacier Fire Protection, L.L.C. 08/30/2018 Oat. Sprinkler Legend Temperature 155`-F Minlassume= U.. to r.-- U., 01 .•-• ...0 cn c Ch-ome .. 433 LI - Response Quick Quick Quick e.) Vl = LI ta , >1 c r.- r- 43 (f) 414 . Quantity! K -Factor 21i 4.9 v'• tri Total ;•-• 24 17,4- 07 F3RES4' DRY RFC 58 Cr 0 TD ti'k T,. 0 Symbol Manufactured SIN •.Reliatle RA0616; iatie RA5231 lade RA06131 IS cc.. • NORTH GLACIER FIRE PROTECTION LLC PO BOX 7980 BONNEY LAKE, WA 98391 °: (253) 501-7558. www.glacierfireprotection.com GLAC1FP834MJ PARCEL # 017900-2501 '2 4 6 8 10 12 SALE: 1/4" = DRAWN BY: SFC REVISIONS NO. DESCRIPTION DATE 08/30/18 CONTRACT #: 40059 FLOOR / AREA MAIN AND UPPER LEVEL SHEET NUMBER FP 2.10 2 of 2 (J