Loading...
HomeMy WebLinkAboutPP - 12519 50TH PL S - CARY LANG CONSTRUCTION / ALLENTOWN LOT 31 - PERMITS AND PLANS12519 50TH PL S ASSOCIATED PERMITS 17-5-054 D16-0340 44111,44 .411M E SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. 0 Site Address: I Z 5 L 9 50Pi S Tenant Name: NA **PLEASE PRINT** Property Owner's Name: (chry ►.-G, C. av►�✓c t. c.4 -c °^ Mailing Address: 25/Z15 `f1 1� v e SIN) J CONTACT PERSON -if there are questions about the submittal. Name: gy Company /Name: Mailing Address: King Co. Assessor's Tax No.: 0177 cx.D2-13-6 S Suite Number: _ Floor: New Tenant? ❑ - Yes ❑ - No Fed. -(4,1 UGC, City Red, •I 14,k �- 1 `eel` 1" ; ie (+dc' b ( \cJle7 Arvr i , 0.1. e % /City vA- 5 8o-3 State Zip Day Telephone: (36316LN-0 07 ?7371 State Zip Fax Number: at5q �3 p L Contractor's City of Tukwila R E-mail Address: IF��� re(��i tr,CD Business License number: NICET III number: D l ` 1- W9T7 Q P Total number of new/relocated devices or sprinkler heads: '31 - Valuation of Project (contractor's bid price): $ . 02S- Scope 2 S 1 Scope of Work (please provide detailed information): ��S�a.11 0-ew ��se SlIP�ti�c p lP S �/s'1 e+in ; ✓\ ffrVe PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 1 R OR AUTHORIZED AGENT: Signature: i" "`_ Print Name: �e 2 " Day Telephone: /3 0) G l ? Date: 3/2(//7 Plan Permit App.doc 8/22/14 TFD FP Form 8 i INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit cil6- (34c PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: eavw ."--2___ Sprinklers: Type of ns on: Hood & Duct: Address: / Pre -Fire: S Contact erson: Suite #: ��� p Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 60P/J le/te-rz_ cove" -E4.57 Aieri) K(0/40r � Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: rim 4t-4- Date: kip /, Hrs.: 1 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 SITE PLAN 10 20 40 SCALE 1"=20'-0" SYMBOLS RED HAWK FIRE PROTECTION, LLC. HYDRAULIC NODE GATE VALVE-N.R.S. (GV) ELECTRIC BELL Without Cornet t: As Noted iri 0 Per The Attached Letter EXISTING SPRINKLER PIPING RED HAWK FIRE PROTECTION, LLC (RHFP) WILL PROVIDE ONE WET PIPE AUTOMATIC SF'RINKLER SYSTEM TO PROTECT THE NEW RESIDENCE. RHFP WILL START WORK AT EXISTING 1 1/4" UNDERGROUND SUPPLY LOCATED IN THE GARAGE: '. . ALL AREAS PROTECTED BY A WET SYSTEM MUST BE MAINTAINED BY OTHERS AT A MINIMUM 40°F TO PREVENT FREEZING. NEW SPRINKLER PIPING BY OTHERS NEW SPRINKLER PIPING BYAPFP These plans have been reviewed 1 ' The Tukwila Fire Prevention Bureau ror conformance current City 5I.<,ndards. Accepe is; subjed t . •*-r ors and omissions which c, : r;;;r authorize ,.sc i. tior , of dopted ::i:andards and orc rc.,:!'. Inca re: C:Kinstrl';iit) for the adequacy of de: ,; otafly v' Icf the designer. Additions; deledoi .x. :,v sions to Cf iF so. drawings after this date wig vo,t.l ;.r ceptance and will require a resubrnittai of rCVi i for subsequent approval. Final acceptai cre is 31.. 0,1eci to field test arta InSpeorkfl by The Tukwila Fire Praventicn Bureau. Pate: 3�5- / 7 By: 1.44 dw reVv uJi. Floes 0' 004,4-) 'erg- rpt tj i • TUKWILA FIRE DEPARTMENT Piense c 206-575.1107 and give this Fire Permit No. /7-S,o5L� and exact 6-dct pss for shut- Jown car resto tion approval. PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT ELECTRICAL WIRING OF ANY KIND INCLUDING BUT NOT LIMITED TO WATERFLOW SWITCH, ELECTRIC BELL, AND TAMPER SWITCHES CENTRAL STATION MONITORING EQUIPMENT WIRING AND. SERVICES CEILING AND WALL REMOVAUREPLACE TO FACILITATE THE INSTALLATION OF THE SPRINKLER SYSTEM. 801 VALLEY AVE NW, SUITE D PUYALLUP, WA 98371 PHONE: (253) 840-9900 Fax (800) 591-4382 WA CL# REDHAHF901GP. ` UNDERGROUND WORK OF ANY KIND (jy�` NEW 1" WATER METER BY OTHERS WASHINGTON STATE CERTIFICATE OF COMPETENCY PORE PROTECTION SPRINKLER SYSTEMS Byron Richard Moye 9419-0815-C Red Hawk Fire Protection, L.L.C. REDHAHFQP. • ALLENTOWN LOT 31 TOTAL SQ. FT.: 3,444 SQ. FT. BUILDING CROSS SECTION 12 12 12 COMPOSITION POOP ilk 3420 INTEaIUOVEN PELT ON 1/2' 2410 PLYWOOD 6NEATHMG ALL ROOF PLASHING TO ESE MIN. 26 GA GALV. STEEL. ROOF DRIP. EDcsES PER eeo. teseeaB.B PROVIDE DRIP EDGE AT EAVES 4 GAISLEE W/ A MIN. 2' OVERLAP. S7. -::::_::.-::E it L.GPT E3ATH UTIL.ITe MASTER BATH 7777Zz777;rsr i8768Z:r3Ut71?MICENA7s1787 V,777 c-rr Ii H SARASE DEN KITCHEN GRAWI..S! AG °' I [1 1. SPRINKLER SYSTEM DESIGN PER NFPA #13D 2013. 2. ALL MATERIALS SHALL BE NEW AND UL AND/OR FM APPROVED: 3. FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH NFPA #13D (2010) AND SPECIFICATIONS. 03/20/2017 [`1}Expires InnatuN Data 1 12131117 4. IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT IS THE OWNERS RESPONSIBILITY TO PROVIDE HEAT THROUGH OUT THE WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE, DELUGE AND OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS:' 5. FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE SPRINKLER SYSTEM OR ANY APPURTENANCES THEREOF. 6. ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING OR PATCHING TO BE BY OTHERS. 7. ALL PIPING IN RESIDENTIAL UNITS TO BE CPVC PIPE: 8. ALL THREADED PIPE TO BE SCHEDULE 40 BLACK JOINED WITH CAST IRON THREADED FITTINGS. 9. ALL WELDED PIPE TO BE SCHEDULE 10 BLACK JOINED WITH GROOVED FITTINGS. 10. ALL GROOVED COUPLINGS TO BE RIGID UNLESS NOTED OTHERWISE.'. 11. SEE FP 1.10 FOR SYSTEM STANDARD DETAILS. 12. ALL HANGERS FOR CPVC ARE TO BE PER DETAILS ON SHEET FP 2:10-30 (UNO). 13. ALL HANGERS FOR STEEL PIPE TO BE NO. 15W SAMMY SIDEWINDER (UNO) 14. ALL PIPE DIMENSIONS ARE CUT LENGTHS (UNO) 15. ALL DRY MAIN PIPING TO BE SLOPED AT 1/4" PER 10'-0" AND ALL DRY LINE PIPING TO BE SLOPED AT 1/2" PER 10'-0". e TO SYSTEM N I I=I I I=1 1=1 �1=1 I—m_m=m 111 -ITC _i J LJ I I-1Tj_l i 1-111 ; l l 1,—III III—III: MAINTAIN 154" ANNUERK7.:1 I h CLEARANCE AROUND PIPE 0 RISER DETAIL 0 1 _2 SCALE 1/2"=1'-0" ITEM # 4 QTY -o SPARE CABINET 0 -c) PER NFPA 13D (2013), CITY OF TUKWILA. RM -01 (RESIDENCE) WET SYSTEM RESIDENTIAL DESIGN DENSITY: MOST DEMANDING 2 HEADS 18x18 MAX SPACING 17GPM/SPRINKLER PER MANUFACTURER Approvals Required CITY OF TUKWILA OWNER / ARCHITECT Revisions 4,4 2 X 11,4" REDUCING COUPLING TYP 1" MALE CPVC ADAPTER TYP BASE OF RISER AT NODE 2 1111iii-1_I 1�I—�1�i,i,111=1T1 iii-1�I—III—Iii—Ii1- .I I I; r iI 11=1 11=1 I I-111=1 11=1 i RISER MATERIAL LIST SIZE DESCRIPTION 1 1 Ph TxT BALL VALVE 2 1 1 POTTER VSR WATERFLOW SWTICH 3 1 6 POTTER PBA246 4 1 6hd SPARE HEAD CABINET CONTAINING: QTY 4 SIZE SPARE HEAD CABINET DESCRIPTION G14906 RESIDENTIAL SPRINKLER HEADS 155° G15606 CONCEALED SPRINKLER HEAD 175° G14231 QR SIDEWALL SPRINKLER HEAD 155° SPRINKLER HEAD WRENCH FOR GL4906. 1 SPRINKLER HEAD WRENCH FOR GL5606 1 SPRINKLER HEAD WRENCH FOR GL4231 FLOW TEST INFORMATION WATER FLOW INFORMATION HAS BEEN PROVIDED BY TUKWILA WATER DEPARTMENT STATIC PRESSURE: 120 (FLOW RESTRICTED TO 75 PSI) RESIDUAL PRESSURE 20 PSI RESIDUAL FLOW: 2966 GPM FP 0.10 SITE PLAN AND NOTES FP 2.10 FIRE SPRINKLER PLAN Contract With: CARY LANG CONSTRUCTION 29815 24TH AVE. SW FEDERAL WAY, WA 98023 CONTACT: CARY LANG Phone: 206-423-5055 Fax: Contract Name: ALLENTOWN LOT 31 12519 50TH AVE. S TUKWILA, WA 98178 Drawing Title SITE PLAN AND .NOTES Key Plan PAID MAR 212011 TUKWILA FIRE Date: Job Number: Designer: Building Permit: March 16, 2017 80076 KYLE WHITT Drawing No. FP 0.10 MASfEV prIVOOM CH: 8-b COVEPEt? POPCli SLOPEP CEILING Off Mill \1"."--- CONNECT TO 01:8-0AQP TOILET JQ �i PLA r1 OOM CONNECT TO TOILET M511: PATH CH: 8-C) KITCHEN CH: 9-0 801 VALLEY AVE NW, SUITE D. PUYALLUP, WA 98371 PHONE: (253) 840-9900 FAX (800) 591-4382 WA CL# REDHAHF901 OP (SEAT PO( M Ci: 9-0 F A111 CH: 8-C HYDRAULLICALY MOST DEMANDING AREA Remote Area 01 -Playroom: OCCUPANCY CLASSIFICATION Residential - 18X18 K -FACTOR 4:9 TOTAL WATER REQUIRED 34..36 TOTAL PRESSURE REQUIRED 61.132 BASE of RISER (gpm) 34:36 BASE of RISER (psi) 44.683 SAFETY MARGIN (psi) +13.854 (18.5%) NICET Stamp WASHINGTON STATE CERTIFICATE OF COMPETENCY TIRE PROTECTION SPRINKLER SYSTEMS Byron Richard Moye 9419-0815-C Red Hawk Fire Protection, L.L.C. REDHAHFQP 03/20/2017 [' iExpires Approvals Required CITY OF TUKWILA OWNER / ARCHITECT 51"Or. CLOSET" Revisions VFW CH: 9-0 CH: 9-O OPEN i0 MOW torr 8-0 SHELF CONNECT TO TOILET COVEKED POPCH GACA CH; 9-0 PI?OOM CH: 8-0 PEl7P0bM 4 01: VAt1L1E17 FIRE SPRINKLER PLAN MAIN FLOOR 2 4 8 0 1 2 MINIMUM DISTANCES FOR ORDINARY= AND INTERMEDIATE -TEMPERATURE RESIDENTIAL SPRINKLERS (NFPA 13D-2002 TABLE 7.5.5.3) . HEAT SOURCE MINIMUM DISTANCE FROM EDGE OF SOURCE TO ORDINARY- SPRINKLER (INCHES) MINIMUM DISTANCE FROM EDGE OF SOURCE TO INTERMEDIATE - SPRINKLER (INCHES) SIDE OF OPEN OR RECESSED FIREPLACE 36 12 FRONT OF RECESSED FIREPLACE 60 36 COAL- OR WOOD- BURNING STOVE 42 12 KITCHEN RANGE 18 9 WALL OVEN 18 9 HOT AIR FLUES 18 9 UNINSULATED HEAT DUCTS 18 9 UNINSULATED HOT WATER PIPES 12 6 SIDE OF CEILING- OR WALL- MOUNTED HOT AIR DIFFUSERS 24 2 FRONT OF WALL MOUNTED HOT AIR DIFFUSERS 36 18 HOT WATER HEATER OR FURNACE g 3 LIGHT FIXTURE: OW -250W 6 3 LIGHT FIXTURE: 250W -499W 12 6 Caution: It is important that the insulation be installed tight against the joists: In unheated areas, any spaces or voids between the insulation and the joists causes the Water in the fire sprinkler piping to freeze.` Contract With: CARY LANG CONSTRUCTION 29815 24TH AVE. SW FEDERAL WAY, WA 98023 CONTACT: CARY LANG Phone: 206-423-5055 Fax: Contract Name: 12519 50TH AVE. S TUKWILA, WA 98178 Caution: For areas having temperatures of 0°F (-18°C) or lower, an additional batt of insulation covering the joist and the fire sprinkler piping should be used. If this is not done, freeze -ups can occur in the sprinkler piping. Drawing Title MAIN FLOOR FIRE SPRINKLER PLAN SCALE 1/4"=1'-0" NOTES 1. ALL PIPE TO BE 1" CPVC UNO 2. SPRINKLERS OMITTED FROM ALL CLOSETS MEETING THE REQUIREMENTS OF SECTION 8.6.3 OF NFPA 13D (2010) AREAS MARKED WITH HATCH 3. SPRINKLERS OMITTED FROM ALL BATHROOMS UNDER 55 FT2 PER SECTION 8.6.2 OF NFPA 13D (2010) AREAS MARKED WITH HATCH HANGER FIG. 511 :111...=a11...... CJITI ` FIG. 126 LAG BOLT HANGER FIG. 514 WOOD JOIST OR COMPOSITE WOOD JOIST 11 0 F i d 0 1 1/2" ni x�- "NO BLOCK" HANGER INSULATION DETAILS Key Plan HANGERS -.PIPE HANGERS SHALL BE SIZED, SPACED AND INSTALLED AS REQUIRED. BY NFPA STANDARDS - NO OTHER PIPING AND/OR DEVICES ARE TO BE ATTACHED TO THE SPRINKLER PIPE HANGER SYSTEM UNLESS THE HANGER HAS BEEN SPECIFICALLY DESIGNED FOR THE ADDITIONAL LOADING. - THIS CONTRACT DOES NOT INCLUDE ANY MATERIAL OR DEVICES TO IMPROVE THE STRUCTURAL STRENGTH OF THE BUILDING TO ENABLE IT TO CARRY THE LOAD OF THE FIRE PROTECTION SYSTEM: - SEE DETAILS ON THIS SHEET FOR THE SPECIFIC HANGER ASSEMBLIES USED FOR THIS INSTALLATION, NFPA 13, 2010 Edition Table 9.2:2.1 MAXIMUM DISTANCE BETWEEN HANGERS (ft in) PIPE TYPE NOMINAL PIPE SIZE ( IN. CPVC Date: Job Number: Designer: Building Permit; March 16, 2017 80076 KYLE WHITT Sprinkler Legend Symbol Manufacturer Response Type SIN K -Factor Size Temperature Finish Escutcheon Spacing Discharge Quantity 0 Globe Quick Pendent GL4906 4.9 '/ 155°F Bronze CONC WHITE 18x18 17 gpm @ 12 psi 27 E" Globe Quick Pendent GL5635 5.6 1 155°F White REC WHITE 225 sq. ft. N/A 4 Globe Quick Pendent GL4910 4.9 % 175°F ' Bronze CONC WHITE 225 sq ft NA 1 Total = 32 Drawing No. FP2..1Q: