HomeMy WebLinkAboutPP - 15650 51ST AVE S - UNKNOWN - PERMITS AND PLANS15650 51STAVE S ASSOCIATED PERMITS 97-5-325 SEWING ROOL THREE CAR GARAGE RISER 300ft F CITY MAIN ® ELEVATION DZEREIELDECIS FIRST FLOOR PLAN SCALE 1/8" = 1'-0" THREE CAR GARAGE GREAT ROOM TOW DAMS OMER SUM MO Mai 1" DRAIN VA. & INSP. TEST SFCON7 FLOOR SCALE 1/8" = 1'-0" 1" CPVC 1" SCH 40 WATER PRESSURE GAUGE WATER FLOW IND PIPE STAND 1" BACKFLOW PREVENTOR 11E—IN TO DOMESTIC WATER 1 1/2" COPPER RISER DETAIL NOT SCALE GENERAL NOTES 1. bVERHEAD SPRINKLER PIPING AND FITTINGS TO BE- CPVC, INSTALLED AND TESTED PER N F P.A. #13D, CITY OF TUKWILA AND THE MANUFACTURERS SPECIFICATIONS - 2 PIPE SIZED PER HYDRAULIC CALCULATIONS SYSTEM DESIGNED PER N.F.P.A. #13D WITH HEADS SPACED ® 400 SQ FT MAX. (20X20) PER MANUFACTURERS SPECIFICATIONS HEADS ARE CENTRAL GBR-2 K=4 3, 2OFT. MAX. BETWEEN HEADS 10FT. MAX OFF WALL 3. MANGERS TO BE TOLCO FIG 23 AND 24 FOR USE WITH CPVC PIPE (SEE DETAIL) - 4 MAXIMUM DISTANCE BETWEEN HANGERS PER CPVC 3 MANUFACTURER I1/2" CPVC -- 7'—O" 1/4" CPVC -- 6'-6" i" CPVC -- 6'—O" 3/4" CPVC -- 5'-6" HANGERS MUST BE LOCATED WITHIN 6" OF EACH DROP. 5 ADEQUATE HEAT AND INSULATION PROVIDED BY OTHERS OWNER TO MANTAIN NEAT AND ISULATION TO PREVENT FREEZING OF WET PIPE SPRINKLER SYSTEM. 6 f ! ALL CASES INSULATION MUST BE PLACED SO THE HEAT FROM INSIDE THE UNITS CAN ?EACH THE WET PIPE INSULATE ONLY ABOVE PIPE IN ATTIC, OUTSIDE ONLY OF PIPE IN EXTERIOR WALLS 7 A►LL AREAS INSIDE UNITS TO HAVE SPRINKLERS EXCEPTIONS AS NOTED, PER N F P A. #13D ;SECTION 4-6 A) SPRINKLERS ARE NOT REQUIRED IN BATHROOMS 55 SQ FT AND LESS 8) SPRINKLERS SPRINKLERS ARE NOT REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES WHERE THE AREA OF THE SPACE DOES NOT EXCEED 24 SQ. FT. AND THE LEAST DIMENSION DOES NOT EXCEED 3 FT AND WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED COMBUSTIBLE MATERIALS AS DEFDIND IN NFPA 220, STANDARDS OF BUILDING A CONSTRUCTION C) SPRINKLERS MAY BE OMITTED FROM GARAGES, OPEN ATTACHED PORCHES, CARPORTS, AND SIMILAR STRUCTURES b) SPRINKLERS MAY BE OMITTED FROM ATTICS, CRAWL SPACES, AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LMNG PURPOSES OR STORAGR. UNDERGROUND NOTES 1 _ UNDERGROUND SHOWN HERE FOR REFERENCE AND HYDRAVLIC CALCULATIONS ONLY 2 ALL UNDERGROUND SUPPLY PIPING TO BE INSTALLED IN ACCORDANCE WITH N F P.A. #24, TUKWILA BUILDING AND WATER DEPARTMENTS STANDARDS AND SPECIFICATIONS. 31, UNDERGROUND TO BE TESTED AND FLUSHED PRIOR TO THE INSTALLATION OF ABOVE - ACCEPTED Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city ztandards Acceptance is subject to errors and Jrnisslons which do no :.ndards and ordina '1eauacy of design rests totally with tete designer tilt ,ns, deletions or revisions to these drawings after LI1}s state will void this acceptance and will require a resubmittal of revFtIi awinz2r subsequent approv' +nal accepts celis subject to field test and inspection by The Tukwila ire - revention Bureau TUKWILA FIRE DEPARTMENT Please call 575.4407 end give this job No97-- and exact address for shut" down or restoration approval. P.V.C. PLASTIC PIPE FIG. 22 FIG.23 FIG.14 WI. HANGER SPACING FASTENER HDHEAD SET APPRDx WEIGHT PER 1OQ NORTH pgMETIM DEC 2 9 1997 RODGER LACY THE SAFETY TEAM, INC. 670 SOUTH LUCILE STREET P.O. BO)c, 81246 SEATTLE, WA. 98108 (206) 762-1450 RODGER LACY SAFETY TEAM INC HANGERS FOR CPVC PLASTIC PIPE UNDERGROUND NOTES