Loading...
HomeMy WebLinkAboutPP - 16249 51ST AVE S - UNKNOWN - PERMITS AND PLANS16249 51STAVE S ASSOCIATED PERMITS 18-5-221 D17-0317 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 53-7 7g. G 6 38 Site Address: r Z'' ? S-1 S T ,y'c5 1 U /< W/ctilite Number: Floor: Tenant Name: Vc / p \Mt #% / 7?LGS l Dom/C E New Tenant? '._ Yes ❑ - No Property Owner's Name: CC, 2 D / 'C! / O '//" n/ / Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. �g Name: R i C- K 13 ER E12- Day Telephone: s` O � 'fro 7 Company Name: ..,1- sr- ichQle x 64- V T/ ods , 4.c. Mailing Address: el Z/O , U p c (Z,c1/1-Ai se,/, -ed 7 14013.0,6-,/, vii es300 � City State Zip E-mail Address: fR t GK • B ERGS 6 € -Isfl/ 4S 6L v T/a'j Fax Number: • C otyi Contractor's City of Tukwila NICET III number: S 7 26.— Os ?/— C61 Business+License number: Total number of new/relocated devices or sprinkler heads: 4.� 7 Valuation of Project (contractor's bid price): $ ,7/ 8 d 0 Scope of Work (please provide detailed information): .Z/V'ST/A-G c. 1Cl I2 0= . p 0.1 N/ K C. F,,l?S /4t r O AI Etei c<<S(p&,-r c PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. AID BUILDING OWNER O AUTHORIZED AGENT: F , Signature: Print Name: I L 61267611 Plan Permit App.doc q UKV lL , !1 Day Telephone: ‘--f Z 5- 8V— e7iP U Date: 4 —/ 8/22/14 TFD FP Form 8 Hydraulic Calculations Sheet 1 for Project Name: Cordon Giovani Residence Location: 16249 51st Ave So. Tukwila, WA Date 10/31/18 Job: GIOVANI Design: Occupancy classification: NFPA #13D Density: 0.05 gpm/sq.ft. Coverage per sprinkler: 16'x 16' MAX Type of sprinklers calculated: Reliable Res Concealed K=4.9 No. of sprinklers calculated: 2 heads Total water required: 43.73 psi @ 26.2 gpm @ Supply Including hose streams 100.00 psi available @ 26.2 gpm Below curve by 56.27 psi Type of System: Wet Water Supply Information: 100.00 psi Somatic Name of Contractor: 1st Fire Solutions Phone Number: Authority Having Jurisdiction: NFPA-13 Program: 'HydroCalc' by Micro Space Systems www.MicroSpaceSystems.com • • i �IOATO0 eTA� BI POW ewo'esa �+o��wa aaw s�r�s��O 392$.0691 -CG Level3 RidI 1st . L.L.C. A'�TIE/ 10F//-�`'�c6 I 1 Flow Test Summary Sheet N1.85 ■ 8 8 0 8 Z (Is)_#ad 9 R R 0 d• ,a EF E E"k aaag '1e R . $##(s! $ 8> •p/0 ,§ • ,2 oc- §k/k §§2` 80mo ■ ■ R B r 0 ■ Static = 100 psi. Cordon Giovani Residence Sheet 3 1st Fire Solutions Description of Fitting abbreviations Code Description PT Plastic Tee PE Plastic 90 degree Elbow BKF Backflow preventor MTR Meter Loss Description of Other abbreviations Code Description AO Arm -over BL Branch Line CM Cross Main PT Total pressure PE Pressure loss due to elevation changes PF Pressure loss due to friction ^.5 Raised to the power of .5 (Square Root) L Actual pipe length F Fitting equivalent pipe length T Total pipe length • GIOVANI 10/31/18 3:19pm Sheet 4 1st Fire Solutions Sprinkler Systems Hydraulic Flow Calculations Cordon Giovani Residence 16249 51st Ave So. Tukwila, WA Raw data previous to any calculations No. Code Diam Length Kfacl Kfac2 Press Elev Hose HW 1 AO1 2 BL1 3 CM1 4 CM1 5 CM1 6 CM1 7 CM1 8 CM1 9 RI1 10 UG1 1.109 11.50 4.9 7.000 1.109 4.00 4.9 7.000 1.109 18.20 BL1 AO1 0.000 1.109 2.20 0.000 1.109 10.00 0.000 1.109 2.20 0.000 1.109 10.50 0.000 1.109 17.00 0.000 1.109 10.00 CM1 -5 0.000 1.358 70.00 RI1 -6 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 20.000 0.000 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 150 150 150 150 150 150 150 150 150 150 Vel Fittings 32 32 32 32 32 32 32 32 32 32 1PT 1PT 1PT 1PT 1PE 1PT 1PT 2PE 1BKF,1PE 1MTR,3PE GIOVANI 10/31/18 3:19pm Sheet 5 1st Fire Solutions Sprinkler Systems Hydraulic Flow Calculations Cordon Giovani Residence 16249 51st Ave So. Tukwila, WA Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Arm -over 1 C = 150 L 11.5 PT 7.00 1 13.0=4.90(7.00)^.5 F 5.0 PE 0.00 1 13.0 1.109 1PT T 16.5 0.02945 PF 0.49 4.3 PT 7.49 3 81 Jct K -factor for arm -over 1 = 13.0/(7.49)".5 = 4.75 GIOVANI 10/31/18 3:19pm Sheet 6 1st Fire Solutions Sprinkler Systems Hydraulic Flow Calculations Cordon Giovani Residence 16249 51st Ave So. Tukwila, WA Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Branchline No. 1 C = 150 L 4.0 PT 7.00 2 End head 13.0=4.90(7.00)^.5 F 5.0 PE 0.00 2 13.0 1.109 1PT T 9.0 0.02945 PF 0.27 4.3 PT 7.27 3 Cross main Jct K -factor for branchline no. 1 = 13.0/(7.27)^.5 = 4.82 GIOVANI 10/31/18 3:19pm Sheet 7 1st Fire Solutions Sprinkler Systems Hydraulic Flow Calculations Cordon Giovani Residence 16249 51st Ave So. Tukwila, WA Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Cross main 1 C = 150 K=9.57=4.82+4.75 L 18.2 PT 7.49 3 BL1 + A01 26.2=9.57(7.49)^.5 F 5.0 PE 0.00 3 26.2 1.109 1PT T 23.2 0.10827 PF 2.51 8.7 L 2.2 PT 10.00 4 F 5.0 PE 0.00 4 26.2 1.109 1PT T 7.2 0.10827 PF 0.78 8.7 L 10.0 PT 10.78 5 F 7.0 PE 0.00 5 26.2 1.109 1PE T 17.0 0.10827 PF 1.84 8.7 L 2.2 PT 12.62 6 F 5.0 PE 0.00 6 26.2 1.109 1PT T 7.2 0.10827 PF 0.78 8.7 L 10.5 PT 13.40 7 F 5.0 PE 0.00 7 26.2 1.109 1PT T 15.5 0.10827 PF 1.68 8.7 L 17.0 PT 15.08 8 F 14.0 PE 0.00 8 26.2 1.109 2PE T 31.0 0.10827 PF 3.36 8.7 PT 18.44 9 Top of Riser K -factor for Cross main 1 = 26.2/(18.44)^.5 = 6.10 GIOVANI 10/31/18 3:19pm Sheet 8 1st Fire Solutions Sprinkler Systems Hydraulic Flow Calculations Cordon Giovani Residence 16249 51st Ave So. Tukwila, WA Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Riser L 10.0 PT 18.44 9 F 7.0 PE 8.66 9 26.2 1.109 1BKF 1PE T 17.0 0.10827 PF 6.84 PT 33.94 10 K -factor for Riser = 26.2/(33.94)^.5 = 4.50 Under ground L 70.0 PT 33.94 10 F 24.0 PE 0.00 10 26.2 1.358 1MTR 3PE T 94.0 0.04036 PF 9.79 PT 43.73 11 Supply pressure available with 26.2 gpm flowing is 100.00 psi, Notes C = 150 CM 1 (EL= 20.0 ft) 8.7 1BKF = 5.00# B.O.R. C = 150 B.O.R. 5.8 1MTR = 6.00# Supply Jct thus system requirement is 56.27 psi below supply curve. (56.3%) GIOVANI 10/31/18 3:19pm Sheet 9 Supply Analysis Node at Static Residual Available Total Required Source Pressure Pressure Flow Pressure Demand Pressure 11 100.00 0.00 0.0 100.00 26.2 43.73 Node Analysis Elevation Node Type Pressure Discharge Node (ft) K -Value Source (psi) (gpm) Notes 1 20.00 Orif= 4.90 2 20.00 Orif= 4.90 3 20.00 4 20.00 5 20.00 6 20.00 7 20.00 8 20.00 9 20.00 10 0.00 11 0.00 Supply 7.00 13.0 7.00 13.0 7.49 - 10.00 10.78 12.62 13.40 15.08 18.44 33.94 43.73 GIOVANI 10/31/18 3:19pm Sheet 10 Pipe Information Nodel Elevl Kfactor Qadd Nominal Fittings L (ft) Cfac Total Pt Pipe (ft) Hose ID F (ft) Vel Elev Pe Node2 Elev2 Qtot Actual Length T (ft) Psi/Ft Fric Pf Notes 1 1 20.00 4.90 13.0 1" 1PT 3 20.00 13.0 1.109 L 11.5 150 Pt 7.00 F 5.0 4.3 Pe 0.00 5.0 T 16.5 0.0295 Pf 0.49 AO1:K=4.75 2 2 20.00 4.90 3 20.00 13.0 1" 1PT L 4.0 150 Pt 7.00 F 5.0 4.3 Pe 0.00 13.0 1.109 5.0 T 9.0 0.0295 Pf 0.27 BL1:K=4.82 3 20.00 9.57 [26.2] 1" 1PT L 18.2 150 Pt 7.49 BL1 + A01 3 F 5.0 8.7 Pe 0.00 4 20.00 26.2 1.109 5.0 T 23.2 0.1083 Pf 2.51 4 4 20.00 5 20.00 1" 1PT L 2.2 150 Pt 10.00 F 5.0 8.7 Pe 0.00 26.2 1.109 5.0 T 7.2 0.1083 Pf 0.78 5 5 20.00 6 20.00 1" 1PE L 10.0 150 Pt 10.78 F 7.0 8.7 Pe 0.00 26.2 1.109 7.0 T 17.0 0.1083 Pf 1.84 6 20.00 1" 1PT L 2.2 150 Pt 12.62 6 F 5.0 8.7 Pe 0.00 7 20.00 26.2 1.109 5.0 T 7.2 0.1083 Pf 0.78 7 7 20.00 8 20.00 1" 1PT L 10.5 150 Pt 13.40 F 5.0 8.7 Pe 0.00 26.2 1.109 5.0 T 15.5 0.1083 Pf 1.68 8 8 20.00 9 20.00 1" 2PE L 17.0 150 Pt 15.08 F 14.0 8.7 Pe 0.00 26.2 1.109 14.0 T 31.0 0.1083 Pf 3.36 9 9 20.00 10 0.00 1" 1BKF 1PE L 10.0 150 Pt 18.44 Top of Riser F 7.0 8.7 Pe 8.66 1BKF = 5.00# 26.2 1.109 7.0 T 17.0 0.1083 Pf 6.84 10 10 0.00 11 0.00 1 1/4" 1MTR 3PE L 70.0 150 Pt 33.94 F 24.0 5.8 Pe 0.00 1MTR = 6.00# 26.2 1.358 24.0 T 94.0 0.0404 Pf 9.79 Supply Z INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 1B -s— 21. Dr?—) PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1/1.0 ��// �_ Z3 gr‹te.e,..6- —Pis Alts A —1/ -- fis //Cra, .auf)*-br - alS11(17-' Needs Shift Inspection: Type of Inspection: Project: 2-100 ReA Address: Contact Person: Suite #: 1(07_t( ST7 %A' _ Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1/1.0 ��// �_ Z3 gr‹te.e,..6- —Pis Alts A —1/ -- fis //Cra, .auf)*-br - alS11(17-' Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 1 Inspector: M,45J Date: 7/2// / Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip;! Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 1 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Ore 691) Sprinklers: Type of Inspection: ii C (Z4 V t 11/0/6) ye/ ue#: Suite #: /6Z4'9 5 ,SCon frve ct Person: Special Instructions: Occupancy Type: , Phone No.: pproved per applicable codes. I I Corrections required prior to approval. COMMENTS: gee% cror>-‘-‘ ntict-3 pK 7'a Com- — ,A -ST Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: , [inspector: X.,_ _ .. /i/S1 Date: /41/ j 9 Hrs.: ID / / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 CANTILEVER n 3 1/2" 11'--1 1/2" Bb 6'-2 3/4" =T BOVE� 2-1" 32'-11 1/2" 43'-3" 506765 4060L0 5'-8" 4 X 10 DFti HDR MAIN FLO2R BEDROOM SUITE 19 6 - HARDWOOD FLO. R CV C in 2 66 SA_H 11 T I�I b P 0 40 N y6 6C B0 51-6" PORCH 2T-4" x 8'-0" 5'-10" 406065 10'-3" 4X10 DF#2HDR TYP. 7, a 1'1' 3060L5 3060R5 FAMILY ROOM HARDWOOD FLOOR STORAGE UNDER STAIRS < 4`1,. (4'_3" 2066 " y l 5'.1" �I 4-2666 3068 551.5 CLC 5156 WEATHER STRIPPED 20 MIN. DOOR. ON , P5 ON DEM HWT 11° o — LAU DRY ND IJ EGH. INT/EXH 1 INr/5X51 1 V O BOLLARD: 4" 5TEEL PIPE CAST IN CONCRETE. 36"TALI. 24" IN GROUND. FILLED WITH CONCRETE. NEW 9096 DIRECT VENT GA5 FURNACE P 4 X 10 DF #(2 HDR T"P. EATING SPACE 0 100 CFM KITCHEN RANGE HOOD OR DOW FT VENT— X11 A„ _ 3'-2" -o KITCHEN _— 5 b" Ij 3 DR =— 4 -4 112" Zv < WITH INTEGRATED FRESH AIR MAKEUP 14A0 DRAWS FRESH AIR FROM OUTDOORS THE SYSTEM USES A MOTORIZED DAMPER CONTROLLED BY A TIMER LOCATED ON THE FURNACE CASING. J 2 GAR GARAGE 511 SOFT e-0? qk LP DRYWALL„ CEILING 5/6" TYPE X COLD WALLS OPTION 1/2" 0755014. 16' X T 5ECTIONAL INSULATED GARAGE DOOR. bX12DF#2HDRTyr. O 16080 16'-2" 4 - iV tY L UP ENTRY HARDWOOD FLOOR 4X 1C DF #2 HD v TYP. t e—. CC1 t0 '0 REFS it 2'-7 1/2" • ui 00 l2 - -1 OG036 I " PANTRY • DINING RM HARDWOOD FLOOR 4X10P112HDR TYP. a 1210FX 3000 1210FX 21'-10" 2-10"T LIVING ,14REA 1287 .1 ft e 43'-2" 8'-51, (n R. (n 206000 40605X • 206050 1 1'-2" 157 FLOOR PLAN SCALE 3/16" = 1' ROOF AND ATTIC 50 YEAR COMPOSITION ROOFING.1. 304 R005I146 FELT. 1/2 EXTERIOR GRADE SHEATHING. ENGINEERED ROOF TRUSS SYSTEM R44 BLOWN IN OR BATT INSULATION INSULATION BAFFLE EVERY TRi155 BAY. VENT BLOCK AT EA. TRUSS BAY: 3L HAVE SEA. 2" DIA. RD. SCREENED HOLES '6 ERIOR000 P5OM TJI 230 NSULATION INTILEVBR I•EDAR 9T 'IGHTLINE POUT TO 4TION I.- 23'-2 1/2" VAPOR BARR OR .004 BLACK VE -QUEEN C VER ENTIRE CRAWL AREA W/ MIN. 1:' /EAM OVERLAP. 6'X1T0F02OBAM 518' 010 GAL/ ANCHOR 80.35 MIN. 7 IMBED INTO 53E5 HALL 94' 0.0.11' MAX FROM CC RNERB 41.-o" ERG1NEERED ROOF TRU555YSTEM OVER GARAGE. TRUSSES at 24'0.0. 61 12 PITCH GARAGE CONSTRUCTION 2 X 6 STUDS® 16" O.C. ALL WARM WALLS INSULATED TOR 21. CEILINGS R494414E195 NEEDED. 5/8" DRYWALL ALL WALLS (WARM WALLSREGUIRED) 5/8" TYPE X DRYWALL CEILING.. 6" X 12" 0502 BEAM 1/4 X 6 0014EL PINS @ 24" 0.6 4" IMBED INTO FDI. WALL 2X10 D.F. J05T®16"0.C. I/O" O.G. WHORL ONT._ I.!" 8' PIER PAO PER PLAN "- 20 !ICAC FTG.ALL EXTERIOR U5 E%CEPT GARAGE A 0055 PER PUN ,E 4X4 T. POST TTP. !�—PBS 44A TYPICAL PT6. ALL EXTERIOR 1,161.1.5 EXCEPT GARAGE SLOPE 1/4' IN 10' BUILDING -SECTION 136 FOUNDATION PLAN SEE SHT 5 NOT TO SCALE 6 X 12 DF #2 CONT. BEAM LINE OF CONC. STEM WALL BEYOND GARAGE 4' 6050. 51.8.0 OYER COMPACTED SOIL WELDED WIRE 5058 — BEDROOM 3 HARDWOOD FL. 3 1/2" 1 O"FILE HP, SNOOD FL. NIARDROBE HARDWOOD FL. A V" 1 4' 5 1/2" 405565 O 4020FX —L I N & as - (0 4X1ODF#2HDR 151-5" 6040L5 5 1/2" 5-1" : < 8'-8" LIVING AREA 1073 sq ft 5 1/2" 10' 5 1/2" 6•X12"•5#2 BEAM 1 LINB OP CONc, STEM/ BEYON. 4" INC T1GHTL1NE DOWNSPOUT TO INFILTRATION TRENCH. T ry 1'-0 1/2" 2NP FLOOR PLAN SCALE 3/16" = 1' 0° EXISTING 6'1,400 FENCE T X I SOIL STOCKPILE TO BE WEATHER PROTECTED DURING WET SEASON 1 X X SILT FENCE —� AtJD CLEARING LIMIT (0 37-11” 110' —X— in ORIGINAL SETBACK SOIL STOCKPILE TO BE WEATHER PROTECT DURING WET SEASON D 1'7 M'4 (8' 7-0 0 FG C�(il ; it I /2 -''.r' 41"1)4:( WATER ETE6 EXISTING ELECT_ ENTRY ENTRY 20'-4 1T -T' 05 ' 0X1 INC 6 50. FD. RES) T. �BED dOLIS)4 0. / OTE 15H' SE53.750NP ' 5AIjmp A5 80 OUNI/ICTION REA1 61X21'G DE LEVEL COVERED FOR H. 186 qF ry PROPOS • D ELEVATION OF / FINISHED $IRST FLOOR 35/43"\ MAIN OOR 16 s4.45.'050/3 NED 517E 111PORM ON: EARL 4 5 96003.. O NER: ORD• 010 NI LOT - REA: 7_82 555/0 STEP 9 5F X150 65141 E5TQRY RE .ENC 690.5 TO DEM ISHE .. /4554P(OPO Ey1DENC . MAI FLOG Wl GARAGE 495 5. F. OPER F . 10735 F. /J EW T STRUG0URALCOV'-- 6E 4% 41' SLI.... TOT S: Fl DSC B 60 F TRU RE ERA 119 MAT INFILTRATION TRENCH SUMP W/ TEE D YE/SETBACK 5 30' CEILING INSULATION (BY OTHERS) MINIMUM 6" 60 MIN. ,101 O Without Comments 0 As Noted in Red Per The Attached Letter ese plans have been reviewed by The Tukwila Fire :vention Bureau for :c;)nforrnance with current City a darils. Accept7nc.T. IS k3. subject rc: enors and Oi3SlonS which do o;: authorize. vioiat-ion ; of adopted yndards and ori is arEc (. The re DoosIbiiity for the 'eq racy of dc. 4s, , '/ CC/tally' with tile dEigner. . Additions/ (,i `r r.fr•11'1 4 :,1.1{) ' to these drawings after this date: I,;ili \'01dis I 11iry1"yr%+ and will require a ' n,^ resubr Itt: ,i' I ,c:f3 1./r subsequent approval. Final accent..".:-' I ;. si.i:: eci' ro lied test and Inspection by • The Tukwila ^=l; "„,'.., bureau. Date: / - 3_1111 ' . By: TUKWILA riP,E DEPARTMENT ` PleasGe c .5 12O�C5575-14')7 and give this b .tiye Permit Noa cinc;11) .e.-.;-S;,t)--)-1,,..ir,s for . )d� or : .ora c)n �¢ Icy ilk, rtq v i r el Flow (bv,,1G •j-) +04 reci/viJ • UTAATED ATTIC SPACE TRUSS CHORD OR JOIST STABILIZED CONSTRUCTION ENTRANCE CANTILEVER ABOVE. REF. PROPOSED ELEVATION OF NEN CONCRETE DRIVE FINISHED FIRST FLOOR 356'3 64555 5 5 47 SILT FENCE AND CLEARING LIMIT -SITE FLAN FIRE HYDRAN r AT CORNER OF 51ST AYE. 5. AND 5.164TH ST. DISTANCE APPROX. 150' 0 (BY OTHERS) HANGER CLIP HEATED 6" MIN: SPRINKLER PIPE 9' 1 1 EARRIER (BY OTHERS) CEILING INSULATION (BY OTHERS) TRUSS CORD 1/2" GYPROCK Notes: VAPOUR BARRIER (BY OTHERS) 1) System Type: Wet 2) All material shall be new and U.L. listed or F.M. approved 3) Fire sprinkler system to be installed braced and tested in accordance with N.F.P,A. #13 4) In localities subject to freezing conditions, it is the owners responsibility to provide heat throughout the wet pipe sprinkler system areas and in enclosures for valves controlling water supplies—to sprinkler systems 5) Pipe and fittings to be CPVC "BLAZEMASTER" 6) Hangers to be TOLCO #22 or #23 (or equal) 7) Hangers spacing: Maximum distance between hangers for CPVC 8) Locate a hanger within 6" of each sprinkler head 9) Sprinkler system designed per N.F.P.A. 13D Pipe 21311 • • • SITATU 1 Rick Berger Demo Level 3 1st Fire SCALE: #54c1 ,,,VorMry DATE: APPROVED BY: DRAWN BY REVISED DRAWING NUMBER MrW -