Loading...
HomeMy WebLinkAboutPP - 12553 51ST PL S - CARY LANG CONSTRUCTION / CODIGO LOT 1 - PERMITS AND PLANS12553 51ST PL S ASSOCIATED PERMITS 18-5-126 D18-0054 46 WZ 4 arr CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. SITE LOCATION Gack Lk L i ZS53 _rS Site Address: _ i 1 P� 5 Suite Number: Floor: Tenant Name: Car A L11 o-i-eUC)I oY\ New Tenant? Zr--Yes ❑ - No Property Owner's Name: "4 I I. t� Mailing Address: a li1l 5- a JA ✓'L 56,2 ri,J44 L(,)i , uJA l eM City 1 State Zip CONTACT PERSON -if there are questions about the submittal. �� Name: M ( \ ] .i)( Day Telephone: (7) 51-19q1 Company Name: 6\j1jtX Fire prt -la/1 L.L.C_ Mailing Address: PG) 6Qi( 1 4i 36 85 nxt/ lake. City City l State Zip E-mail Address: \ t beSI q Lr 4 p C:d f ) Fax Number: Contractor's City of Tukwila NICET III number: &(�1 — ©, C Business License number: Total number of new/relocated devices or sprinkler heads: Qq. Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): N f;2_14) t 14. 5 p 1 1,\;, 6y[ ,4 (3 () **PLEASE PRINT** King Co. Assessor's Tax No.: 017966— )66 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A Signature: Print Name: Q� O� AGE • Plan Permit App.doc B4> E Date: Ca -0-066 Day Telephone 111 1 l' 1 r)d 8/22/14 TFD FP Form 8 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit "Dm OCGtf' PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:LA-- Cedlir.Address: � Type of I�n�spn: Suite #: 126-.5:3 ci iti S Contact Person: Special Instructions: Occupancy Type: Phone No.: pproved per applicable codes. Corrections required prior to approval. COMMENTS: fao-1 — PAss Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: - i M53 Date: mg/ l b Hrs.: 1, 0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: el Loi I Fire Alarm: Type of Inspection: Address:' Suite #: r t, 5 Pre -Fire: S- Contact Person: Special Instructions: Phone No.: proved per applicable codes. Corrections required prior to approval. del,..\A15- COMMENTS: de-- Cov.e, 964-7 /* ,Net(syea /53 sre. e 112,1.4.,"J tArls dk_ Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 1 Inspector:f yam, c4-- Date:W V/a Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 SITE PLAN 0 4 8 16 32 SCALE 1/16"=1'-0" GENERAL NOTES SCOPE OF WORK p Without Comments As Noted in Red O Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinance:. The responsibility for the adequacy of desigr ;;sis totally with the designer. Additions, deletion: :visions to these drawings after thy r, ,1f vvill this;c; eptance and will require a orawinosl for subsequent approval. Final accept i suoject o rielca test and inspection by The Tukwila Fire Prevention Bureau. Date: (o - �. ' _By: 147 ✓rt,,iie-A1. /, Flow (1,4,1,0-) TCJ'� ✓ev, h). TUMILA FIRE DEPARTMENT + E'� ° 2O$-575-' v0/ and. this Are Per rnit o Ca I�eloct address for shut . S w6�n pg � or ��. yq� approval 4;.7� 0 '_.,:4..ra �7 r 31 M Ofl ap ro CPVC PIPE STRAP AFCON MODEL 510 CPVC PIPE HEX HEAD SELF TAPPING SCREW AFCON #905 DOUBLE FASTENER CPVC PIPE STRAP TYPICAL HANGER DETAIL #1 SCALE : N.T.S. 120V 6" BELL NEW CITY CONNECTION BY OTHERS �W 1" WATER METER • GLACIER FIRE PROTECTION, LLC` r� TO START AT 1 112" BACKFLOW • @ 1'-10" AFF WOOD LAG SCREW AFCON #514 HANGER CPVC SPRINKLER PIPE WOOD STRUCTURE TYPICAL HANGER DETAIL #2 SCALE : N.T.S. /HANGER APPLICATION RESTRAINER APPLICATION HEX SCREW HEAD SELF CPVC PIPE SINGLE FASTENER CPVC PIPE STRAP TYPICAL HANGER DETAIL #3 SCALE : N.T.S. 1. THE FIRE PROTECTION SPRINKLER SYSTEM FOR THE SINGLE FAMILY DWELLING UNIT SHALL BE DESIGNED AND INSTALLED PER NFPA 13D, 2013. 2. CALCULATION FOR THE RESIDENCE SHALL BE PER NFPA 13D, 2013. 3. PIPE THROUGHOUT THE DWELLING UNIT TO BE CPVC SPRINKLER PIPING UNLESS NOTED OTHERWISE. 4. ALL HANGERS SHALL BE PLACED AND INSTALLED IN ACCORDANCE WITH NFPA 13, 2013. 5. SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 SQ.FT. AND LESS. 6. SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES THAT ARE LESS THEN 24 SQ.FT., THE LEAST DIMENSION DOES NOT EXCEED 3'-0 AND THE ROOM IS SURFACED WITH NONCOMBUSTIBLE OR LIMITED COMBUSTIBLE MATERIALS. 7. SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES, OPEN ATTACHED PORCHES, CARPORTS, AND SIMILAR STRUCTURES. 8. SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS, CONCEALED SPACES, FLOOR/CEILING SPACES, CRAWL SPACES, AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING PURPOSES AND DO NOT CONTAIN FUEL -FIRED EQUIPMENT. 9. WIRING OF ANY NEW DEVICES IF REQUIRED IS BY OTHERS. 10. PAINTING AND LABELING OF PIPING IF REQUIRED IS BY OTHERS. FIRE SPRINKLERS SHALL NOT BE PAINTED OVER. 11. IT SHALL BE THE OWNERS RESPONSIBILITY TO MAINTAIN THE TEMPERATURE ABOVE 40° AT ALL TIMES. 12. A MAIN DRAIN IS TO BE PROVIDED AND INSTALLED IN ACCORDANCE WITH NFPA-13D. HUB DRAINS TO BE PROVIDED BY OTHERS AS NEEDED. 13. NO GYP. BD. CEILINGS SHALL BE INSTALLED UNTIL ROUGH VISUAL INSPECTION IS COMPLETE. 14. MAXIMUM RESIDENTIAL PENDANT SPRINKLER SPACING COVERAGE 16-0 x 16'-0. MAXIMUM DRY SIDEWALL SPRINKLER HEAD SPACING 14'-0 X 14'-0. MAXIMUM RESIDENTIAL DRY SIDEWALL SPRINKLER HEAD SPACING 16-0 X 20'-0. 15. MINIMUM RESIDENTIAL PENDANT SPRINKLER SPACING 8'-0 O.C. MINIMUM DRY SIDEWALL SPRINKLER SPACING 6'-0 O.C. MINIMUM RESIDENTIAL DRY SIDEWALL SPRINKLER SPACING 8'-0 O.C. 16. ALL VALVES TO BE LABELED IN ACCORDANCE WITH NFPA-13D. 17. PIPE SHALL BE REQUIRED TO REMAIN ON A 2.25" CENTERLINE ON THE TOP OF THE BOTTOM TRUSS CORD ALLOWING FOR TENTING AND SHALL HAVE PRIORITY OVER OTHER TRADES. GLACIER FIRE PROTECTION WILL PROVIDE ONE WET PIPE AUTOMATIC SPRINKLER SYSTEM TO PROTECT THE NEW RESIDENCE. EXCLUSIONS PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT ELECTRICAL WIRING OF ANY KIND INCLUDING BUT NOT LIMITED TO WATERFLOW SWITCH, ELECTRIC BELL, AND TAMPER SWITCHES CENTRAL STATION MONITORING EQUIPMENT, WIRING AND SERVICES CEILING AND WALL REMOVAL/REPLACE TO FACILITATE THE INSTALLATION OF THE SPRINKLER SYSTEM, UNDERGROUND WORK OF ANY KIND DESIGN CRITERIA PER NFPA 13D (2016) RM -01 (RESIDENCE) THE DENSITY SHALL BE 13 GPM/SF OVER THE MOST REMOTE 2 SPRINKLERS WITHIN A COMPARTMENT. 16'-0 x 16-0 MAX SPACING Sprinkler Legend Finish Temperature u- rn rn Lo - Chrome 1175°F u- 0 N N (I) ) Response U ,Quick Quick O (1) N cn T Type Pendent 1 (Pendent CO L o) 4.4 5.8 U tl LL Quantity N N T Total = 28 Model RFC49 F3RES44 DRY] RFC 58 Z (9 M le RA0613 LQ Q Ct Manufacturer) (1) a) .n 2T s mca T) .63 ca T)017-6. (Symbol. WATER FLOW INFORMATION NORTH FIRE SPRINKLER RISER WATER GAUGE 1" DRAIN FLOW SWITCH DOMESTIC LINE BY OTHERS _I 1- MAINTAIN 2" ANNULAR CLEARANCE AROUND PIPE 12553 51ST PL S Write a description foryour map: GLACIER FIRE PROTECTION, LLC TO START WORK HERE 1 112" AMES 2000B BACKFLOW PREVENTOR PROVIDED AND INSTALLED BY GLACIER FIRE PROTECTION, LLC 1 112" WATER ENTRY BY OTHERS I-! 1 I_ I- 1 1-1 1 ._ 1 I !. I-1 WATER FLOW INFORMATION HAS BEEN PROVIDED BY TUKWILLA PUBLIC WORKS DEPARTMENT STATIC: 148 PSI RESIDUAL: 20 PSI FLOW: 4910 GPM GLACIER FIRE PROTECTION LLC PO BOX 7980 BONNEY LAKE, WA 98391 P: (253)501-7558 www.glacierfireprotection.com GLACIFP834MJ DRAWING INDEX FP 0.10 SITE PLAN AND NOTES FP 2.10 MAIN AND UPPER LEVEL PLAN PARCEL # 017900-2410 TIEFICARTE *Er ct MP TE$CY nits NWT's SPYIBTEM3 Erin Clayton 7544-0817-C Level 3 Glacier Fire Protection, L.L.C. GLACIFP834MJ 06/05/2018r r.c►a.-.w.....rr� anature Data sar��.w•.,w�..,.s.�wrr 00 T- 00 00 0) CO VICINITY MAP rend 12553 51st PI PAI JUN 13 2010 MI FIRE SITE PLAN AND NOTES SPRINKLER PLAN 0 2 4 6 8 10 12 SCALE: 1/16" =1'-0" DRAWN BY: SFC REVISIONS DATE: 06/06/18 CONTRACT #: 40040 FLOOR /AREA SITE PLAN AND NOTES SHEET NUMBER FP 0.10 1 of 2 • DINING KITCHEN 1 FAMILY ROOM 1 j 10'-0 3'-53/4 3'-9'/4 6'-0 �0 c 1 11'-63/4 2'-6'/4 2'-4?4 ENTRY OPEN TO ABOVE GARAGE 10'-8'/4 ARMOVER/DROP Hydraulic Information Remote Area 1 OCCUPANCY CLASSIFICATION Residential DENSITY 0.050gpmlftfor 900.00ft2 (Actual 222.42ft2) TOTAL HEADS FLOWING 2 K -FACTOR 4.9 TOTAL WATER REQUIRED 26.30 TOTAL PRESSURE REQUIRED 38.830 BASE of RISER (gpm) 26.30 BASE of RISER (psi) 38.830 SAFETY MARGIN (psi) +109.162 (73.8%) 0 CO 3'-8 BEDROOM 3 BEDROOM 2 PLAYROOM UTILITY iiiariarraiarirriiiaiirrr % _>�. A MAIN LEVEL PLAN SCALE : 114" = 1'-0 MINIMUM DISTANCES FOR TEMPERATURE RESIDENTIAL SPRINKLERS HEAT SOURCE 165 DEGREE 1" 200 DEGREE 1 1/2" 2" 2 1/2" 3" SIDE OF OPEN OR RECESSED FIRE PLACE 36 in 8" 12 in FRONT OF RECESSED FIREPLACE 60 in 12-0 36 in COAL -OR WOOD BURNING STOVE 42 in 15-0 12 in KITCHEN RANGE 18 in THREADED LIGHTWALL 9in WALL OVEN 18 in 12-0 9in HOT AIR FLUES 18 in N/A 9in UNINSULATED HEAT DUCTS 18 in 8-0 9in UNINSULATED HOT WATER PIPES 12 in 12-0 6 in SIDE OF CEILING OR WALL MOUNTED HOT AIR DIFFUSERS 24 in 15-0 12 in FRONT OF WALL MOUNTED HOT AIR DIFFUSERS 36 in 6-0 18 in HOT WATER HEATER OR FURNACE 6 in 9-0 3 in LIGHT FIXTURE N/A N/A PER NFPA 13 9.2.2.1 (A) OW -250W 6 in 3 in PER NFPA 13D TABLE 7.5.5.3 HANGER SPACING LEGEND NOMINAL PIPE SIZE (IN.) 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" STEEL PIPE SCH 40, SCH 10, DF,EF N/A 12-0 12-0 15-0 15-0 15-0 15-0 15-0 15-0 15-0 THREADED LIGHTWALL N/A 12-0 12-0 12-0 12-0 12-0 N/A N/A N/A N/A COPPER 8-0 8-0 10-0 10-0 12-0 12-0 12-0 15-0 15-0 15-0 CPVC 5-6 6-0 6-6 7-0 8-0 _ 9-0 10-0 N/A N/A N/A PER NFPA 13 9.2.2.1 (A) 7 0 i 11 II 7 P di 1'-71/2 5'-111/4 11'-43/4 7'-9 " " 2'-0 6'-1% /ii///d I DROP DETAILS SCALE :N.T.S. 1 1 2'-5'/2 5'-0 `opo ii,__`%` .... aP# . ######Z z A � . • OPEN TO 5'-11A '/ MEDIA ROOM 4'-2'/4 BELOW F� 41W / MASTER BEDROOM MASTER BATH 2'-51/ i STAND OFF HANGER #10x1" HEX HEAD CAP SCREW INSUALTION BY OTHERS VAPOR BARRIER STAPLED COMPOSITE WOOD I -JOIST 10d NAIL (TYP) WOOD BLOCKING GYP. BOARD/ T&G CEILING TJI SPACE SEMI-REC. PENDENT SPRINKLER PIPE TENT INSULATION DETAIL #3 SCALE : N.T.S. UPPER LEVEL PLAN SCALE : 114" = 1'-0 BLOWN -IN INSULATION ABOVE BATT INSULATION BY OTHERS BATT TYPE INSULATION COLD SPACE TRUSS CHORD OR JOIST GYPSUM BOARD CEILING PIPE TENT INSULATION DETAIL #2 SCALE : N.T.S. PIPE SHALL BE REQUIRED TO REMAIN ON A 2.25" CENTERLINE ON THE TOP OF THE BOTTOM TRUSS CORD ALLOWING FOR TENTING AND SHALL HAVE PRIORITY OVER OTHER TRADES. ADEQUATE INSULATION BY OTHERS SPRAY RIGID FOAM INSULATION BY OTHERS —1I ,I H11 � 1 I II II II . -1**INA v .N.4‘ - '2," 0 .\'' >< X , i`� 4 ; Xf". NO -BLOCK FASTENER �♦�♦�' 4 xv , S .'\ K. • _ -- m WA •it 41110 %* l' CPVC PIPE - • 4‘ • • \ ---,J— TJI JOIST PIPE TENT INSULATION DETAIL #1 SCALE : N.T.S. WASHINGTON STATE CERTIFICATE OF COMPETE P CY FIRE PROTECTION SPRINKLER SYSTEMS Erin Clayton 7544-0817-C Level 3 Glacier Fire Protection, L.L.C. GLACIFP834MJ 06/04/2018 a xIr+m 1 1 1 1 Sprinkler Legend 0 uo U) u- u0 N .2 IL a) Q) E 0 U a) d) N 0 N LJ� 0 7 5 0 U U 0 w N_ F- a a) 0 cn a a a) v U (0 LL ui N c c� C� cO N a) O 0) U IL F3RES44 DRY 03 U IL z M_ U ca a) co ITC) a) a) a) a) o_ 0 • T NORTH GLACIER FIRE PROTECTION LLC PO BOX 7980 BONNEY LAKE, WA 98391 P: (253) 501-7558 www.glacierfireprotection.com GLACIFP834MJ PARCEL # 017900-2410 co cn r15 alL' J n La or) ai I- MAIN AND UPPER LEVEL SPRINKLER PLAN 0 2 4 6 8 10 12 Its SCALE: 1/4" = 1'-0" DRAWN BY: REVISIONS NO. DESCRIPTION A /Z\ DATE: 06/04/18 CONTRACT #: 40040 FLOOR / AREA MAIN AND UPPER LEVEL SHEET NUMBER FP 2.10 2 of 2