Loading...
HomeMy WebLinkAboutPP - 14236 52ND AVE S - UNKNOWN - PERMITS AND PLANS14236 52ND AVE S ASSOCIATED PERMITS 95-5-098 DESIGN CALCULATIONS (NFPA 13D) RESIDENTIAL FIRE SPRINKLER SYSTEM Project Name: al RES(p Project Location: 14231D. 5 2 — VC,, S, T) t .g.p.m. at •S -S p.s.i.; Available Water Supply: Max. Sprinkler Spacing / ft. X ft. Sheet no. r' of Date: LI By• /. Floor Level: a �Elev. of Spkrs. qi I� v1 Location Sprinkler I D Ceo.6-a ( Qv7iG 7--1 hit One -sprinkle design Min. flow )9 g.p.m.; Min. pressure p.s.i. Two -sprinkler design Min. flow g.p.m.; Min. pressureI I k I 1. Type of piping: CPVC O PB O Steel (Sch. 40) O Copper K, L, M (circle one) CALCULATIONS 2 -sprinkler flow: System demand = ZZ gpm PIPING (1-spkr. flow= g.p.m.) TOT UNIT _ TOTAL DIGTH FR. LOSS FR. LOSS CALCULATIONS / L 1 sprinkler flow: System demand = g.p.m. PIPING (1-spkr flow) TOTAL X UNIT TOTAL DIA LENGTH FR. LOSS FR. LOSS StVVI('(',G" 'f5'X0/01 ,S CPrL r ler ,03q /,l7 FITTINGS & VALVES (1-spkr. flow) DIA & X UNIT TOTAL X UNIT __ TOTAL TYPE QTY. EQ. LEN. EQ. LEN. FR. LOSS FR. LOSS br$1 f S 20 ,a ,68 27,5 ,03q • +6/41 !/ TNY) q 1,5 /3,5" ,03' , L; I-\vks roicztr,i5ciaF. C -w rcJe.n4C1, METER FRICTION LOSS (size = ) ) SPRINKLER PRESSURE REQUIRED ELEVATION HEAD LOSS (2 -oft. X 0.433) TOTAL SYSTEM PRESSURE DEMAND TOTAL SUPPLY PRESSURE AVAILABLE 129 133,31 15s/ I 2-spkr. flow= g.p.m.) awl 1' /H" 55 , 02 2 1,13 L 1' ,d783 5,131 FITTINGS & VALVES (1-spkr. flow = g.p.m.) DIA & UNIT _ TOTALTomAL TYPE QTY. X EQ. LEN. — E . LOSS_ FR. LOSS FITTINGS & VALVES (2-spkr. flow=27,g.p.m.) S 2c 45783 /, Sb loo 1/ 2, 4- 2-7,5 ,a7n Z,( r3,5 ,0733 1fc� 1150 DC .(cCluL) ?revev 1.cr 54 METER FRICTION LOSS (size = /) SPRINKLER PRESSURE REQUIRED ELEVATION HEAD LOSS (ZO ft. X 0.433) TOTAL SYSTEM PRESSURE DEMAND TOTAL SUPPLY PRESSURE AVAILABLE 3 ,0 t,o .35,29 (over, for data tables) Reorder from: Central Sprinkler Corporation, Customer Service Department 451 N. Cannon Avenue, Lansdale, PA 19446 (800) 523-6512 In PA (215) 362-0700 ° 1987 DATA SHT. 871 n 1011111•1•110.1111•11111. 00 4' • PROP. LINE 60' I � _ / / / / / r GARAGE y Ir n•-• se OID 52nd AVE 5 20x20 \\COLIC. PAD cic 0 PROPERTY N .01 A _J 200 MR4 ATE FI DOOM 4 FRAME w/ r CLOSER bra" TYPE 'x' au.e • WALLS ADJACENT TO LIv1rrG 6P1C2 4 ALL MG GARAGE r 12 11 11 11 11 11 1 awl tow AMMIIMMINIS aimmomomol 41-0' 1V->att 4'-0n 20.-0° WEST ELEVATION SCALE: 1/4" m 1'-O" MAim L cfl _J FURNACE TO HAVE MIN. EFFICIENCY RATING OF 18% AFUE WHOLE HOUSE VENTILATION TO BE INTEGRATED WITH FORCED AIR HEATING SYSTEM TO MEET CURRENT WASHINGTON STATE ENERGY CODE 16' X T GARAGE o OOR TUKWILA FIRE DEPARTMENT Please call: 575-4407 and give this job No. g and exact address for shut• down or restoration approval. —r rf rc 1 jQ 5Fg./ 14 KI. -. u' -77/PC.-fN& "CP/C-, COET El WITHOUT COMMENTS. SAS NOTED IN RED ❑ PER THE ATTAC:IED LETTER The drawings affixed hereto have been reviewed and accepted by the City of Tukwila Fire Dept. Aiditians, deletions or revisions to these drawings after this date will. void this acceptince and will require a resubmittal of revised drawings. Final acceptance is subject to field - inspection by a representative of this department -"DATE: gBY CITY OF TUKWILA 575-4407 P/0tii 1.311 6 &AWN/ 461/ it tR 4:19i5 -15V1L-DlM(7 39-1 -- O33G1 FIRS �' �1KLE 2-'' � (11).EN1C.r y51 -9q1? 147-3.0 5'2°Ave" S. -roK..W (1-1,1 SCALE: IA • G la DATE: APPROVED BY: DRAWN BY/ REVISED I„ 3tn4-1,vlc1i '1 SYIY+5 4122G /004-1'Avt, E. f(op , ti . 9853/.2* DRAWING NUMBER /C >/ -\11/(-510FsVrbo3 22 X 14 FAINTED ON NO, 1000H CLEARPPIMT • 1 de -M,4