PP - 14025 53RD AVE S - UNKNOWN - PERMITS AND PLANS
14025 53RD AVE S ASSOCIATED PERMITS 17-5-160 SITE PLAN 0 5 10 20 40 SCALE 1"=20'-0" GENERAL NOTES O Without Comments As Noted in Red © Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City Standards. Acceptance is subject to errors and omissions which do riot authorize violations of adopted standards and ordinances, The responsibility for the adequacy of desigr; : !gists totally with the designer. Additions, deletions revosions to tnese drawings after this date will void this icceptarlce and will require a resubmittal cif reviseo drawings for subsequent u:)proval. Final acceptz ce Is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: 9-C--/ 7 By: S , X Flow. (5..1k4) 'J -.e, ret,,, ►-1..U1. TUKWILA FIRS DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. 17-S- 0 and exact address for shut- down or htstoration approval. 00 uPpl;p II.00E t MAIN fl-OOp 3Nl u1:13dOUd (7 w 00 NEW CITY CONNECTION BY OTHERS c') NEW 1"WATER METER BY OTHERS Sa3Hl0 A8 PROPERTY LINE NEW ELEC. BELL m 1 PRINKLER PIPE 1. THE FIRE PROTECTION SPRINKLER SYSTEM FOR THE SINGLE FAMILY DWELLING UNIT SHALL BE DESIGNED AND INSTALLED PER NFPA 13D, 2013. 2. CALCULATION FOR THE RESIDENCE SHALL BE PER NFPA 13D, 2013. 3. PIPE THROUGHOUT THE DWELLING UNIT TO BE FLAMEGAURD CPVC SPRINKLER PIPING UNLESS NOTED OTHERWISE. 4. ALL HANGERS SHALL BE PLACED AND INSTALLED IN ACCORDANCE WITH NFPA 13, 2013. 5. SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 SQ.FT. AND LESS. 6. SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHS CLOSETS, LINEN CLOSETS, AND PANTRIES THAT ARE LESS THEN 24 SQ.FT., THE LEAST DIMENSION DOES NOT EXCEED 3'-0 AND THE ROOM IS SURFACED WITH NONCOMBUSTIBLE OR LIMITED COMBUSTIBLE MATERALS. 7. SPRINKLERS SHALL NOT BE REQUIRED IN OPEN ATTACHED PORCHES, CARPORTS, AND SIMILAR STRUCTURES. 8. SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS, CONCEALED SPACES, FLOOR/CEILING SPACES, CRAWL SPACES, AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING PURPOSES AND DO NOT CONTAIN FUEL -FIRED EQUIPMENT. 9. WIRING OF ANY NEW DEVICES IF REQUIRED IS BY OTHERS. 10. PAINTING AND LABELING OF PIPING IF REQUIRED IS BY OTHERS. FIRE SPRINKLERS SHALL NOT BE PAINTED OVER. 11. IT SHALL BE THE OWNERS RESPONSIBILITY TO MAINTAIN THE TEMPERATURE ABOVE 400AT ALL TIMES. 12. A MAIN DRAIN IS TO BE PROVIDED AND INSTALLED IN ACCORDANCE WITH NFPA-13D. 13. NO GYP. BD. CEILINGS SHALL BE INSTALLED UNTIL ROUGH VISUAL INSPECTION IS COMPLETE. 14. STOCK OF SPARE SPRINKLERS OF EACH TYPE INCLUDING WRENCH WILL BE PROVIDED PER NFPA 13. 15. MAXIMUM SPRINKLER SPACING COVERAGE 16'-0 x 16'-0 AND 18'-0 x 18'-0. 16. ALL VALVES TO BE LABELED IN ACCORDANCE WITH NFPA-13D. 17. PIPE SHALL BE REQUIRED TO REMAIN ON A 2" CENTERLINE ON THE TOP OF THE BOTTOM TRUSS CORD ALLOWING FOR TENTING AND SHALL HAVE PRIORITY OVER OTHER TRADES. SCOPE OF WORK GLACIER FIRE PROTECTION WILL PROVIDE ONE WET PIPE AUTOMATIC SPRINKLER SYSTEM TO PROTECT THE NEW RESIDENCE. A REGISTERED LEVEL ONE PLUMBER SHALL TAP INTO THE SPRINKLER SYSTEM WHERE SHOWN AND TIE INTO TOILET. EXCLUSIONS PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT ELECTRICAL WIRING OF ANY KIND INCLUDING BUT NOT LIMITED TO WATERFLOW SWITCH, ELECTRIC BELL, AND TAMPER SWITCHES CENTRAL STATION MONITORING EQUIPMENT, WIRING AND SERVICES CEILING AND WALL REMOVAL/REPLACE TO FACILITATE THE INSTALLATION OF THE SPRINKLER SYSTEM. UNDERGROUND WORK OF ANY KIND DESIGN CRITERIA PER NFPA 13D (2013), CITY OF TUKWILA. RM -01 (RESIDENCE) THE DENSITY SHALL BE 20 GPM/SF OVER THE MOST REMOTE 2 SPRINKLERS WITHIN A COMPARTMENT. Sprinkler Legend a. E H tL u 0 T �'n -c N c a) m N o. c 0 N N Ir 0 Q O N N in a a) tl c c a) a. 0) . ar u; c0 c co o co Tis 0 0 2 0) U u_ G5-56 DRY 0 Z L 0 0 4— cTS co 0) IY a) c0 a) 0 E a 0) FLOW TEST INFORMATION NORTH FIRE SPRINKLER RISER WATER GAUGE 1" x 1" x 1" CPVC SPRINKLER HEAD TEE-- �J SPARE CABINET SSV 120-6 ALARM BELL -1" x 1" x CPVC SPRINKLER HEAD TEE - ---1" DRAIN 1" WFDNF WATER DETECTOR ----- 1" x 1" x 1" CPVC SPRINKLER HEAD TEE BASE OF RISER .' NODE 2 I III=III=III-III=III-III=III -I I I MAINTAIN 2" ANNULAR CLEARANCE AROUND PIPE 11=1 11=1 1 ' WATER FLOW INFORMATION HAS BEEN PROVIDED BY MIKE CUSICK w/ TUKWILAWA SEWER/VVATER STATIC PRESSURE: 150 (FLOW RESTRICTED TO 130 PSI) RESIDUAL PRESSURE 20 PSI RESIDUAL FLOW: 1792 GPM DRAWING INDEX FP 0.10 SITE PLAN AND NOTES FP 2.10 MAIN FLOOR FIRE SPRINKLER PLAN FP 2.20 UPPER FLOOR FIRE SPRINKLER PLAN WASHINGTON STATE CERTIFICATE OP COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Erin Clayton 7544-0817-C Level 3 Glacier Fire Protection, L.L.C. GLACIFP834MJ 08/23/2017 Slgnaturo pate Wren 12./3'1117 Colgrove Lot 9 Write a description for your ma VICINITY MAP P I1, GLACIER FIRE PROTECTION LLC PO BOX 7980 BONNEY LAKE, WA 98391 P: (253)501-7558 www.glacierfireprotection.com GLACIFP834MJ 0 2 4 6 8 10 12 SCALE: 1/8" =1'-0" DRAWN BY: ERIN CLAYTON NO. REVISIONS DESCRIPTION CITY APPROVAL DATE: 08/24/17 CONTRACT #: 40001 FLOOR /AREA AM 25 SITE PLAN AND NOTES TUKWILA f let, - :IRE SHEET NUMBER FP 0.10 1 of 3 77tFOYER MAIN FLOOR PLAN SCALE : 1/4" =1 LO HANGER SPACING LEGEND NOMINAL PIPE SIZE (IN.) 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" STEEL PIPE SCH 40, SCH 10, DF,EF N/A 12-0 12-0 15-0 15-0 15-0 15-0 15-0 15-0 15-0 THREADED JGHTWALL N/A 12-0 12-0 12-0 12-0 12-0 N/A N/A N/A N/A COPPER 8-0 8-0 10-0 10-0 12-0 12-0 12-0 15-0 15-0 15-0 CPVC 5-6 6-0 6-6 7-0 8-0 9-0 10-0 N/A N/A N/A _ _ PER NFPA 13 9.2.2.1 (A) CPVC PIPE STRAP AFCON MODEL 510 CPVC PIPE/ HEX HEAD SELF TAPPING SCREW AFCON #905 DOUBLE FASTENER CPVC PIPE STRAP TYPICAL HANGER DETAIL #1 SCALE : N.T.S. WOOD LAG SCREW AFCON #514 HANGER CPVC SPRINKLER PIPE WOOD STRUCTURE TYPICAL HANGER DETAIL #2 SCALE : N.T.S. /HANGER APPLICATION RESTRAINER APPLICATION HEX HEAD SELF TAPPING SCREW\ CPVC PIPE SINGLE FASTENER CPVC PIPE STRAP TYPICAL HANGER DETAIL #3 MINIMUM DISTANCES FOR TEMPERATURE RESIDENTIAL SPRINKLERS HEAT SOURCE 165 DEGREE 200 DEGREE SIDE OF OPEN OR RECESSED FIRE PLACE 36 in 12 in FRONT OF RECESSED FIREPLACE 60 in 36 in COAL -OR WOOD BURNING STOVE 42 in 12 in KITCHEN RANGE 18 in 9 in WALL OVEN 18 in 9 in HOT AIR FLUES 18 in - 9 in UNINSULATED HEAT DUCTS 18 in 9 in UNINSULATED HOT WATER PIPES 12 in 6 in SIDE OF CEILING OR WALL MOUNTED HOT AIR DIFFUSERS 24 in 12 in FRONT OF WALL MOUNTED HOT AIR DIFFUSERS 36 in 18 in HOT WATER HEATER OR FURNACE 6 in 3 in LIGHT FIXTURE OW -250W 6 in 3 in PER NFPA 13D TABLE 7.5.5.3 SCALE : N.T.S. WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Erin Clayton 7544-0817-C Level 3 Glacier Fire Protection, L.L.C. GLACIFP834MJ 08123/2017 lgnataro Data Sprinkler Legend IL tor) LC) N E IL a) a) 1 :1= - 'S:C .c 1) O 0 d N N_ N ^W hA a) 13 IL y 1✓ 73 I✓ a) IZ 0) as co N C t0 0 v co I N O a) 0 LL cc G5-56 DRY z 0) L 15 c ns 2 a) rci .0)m n 0N - o u) - ou J Q > < W JLC) • Lo v rnI- CY) w w J c LU 0 SPRINKLER PLAN GLACIER FIRE PROTECTION LLC PO BOX 7980 BONNEY LAKE, WA 98391 P: (253) 501-7558 www.glacierfireprotection.com GLACIFP834MJ 0 2 4 6 8 10 12 SCALE: 1/4" = 1'-0" DRAWN BY: ERIN CLAYTON REVISIONS NO. DESCRIPTION / \ CITY APPROVAL DATE: 08/24/17 CONTRACT #: 40002 FLOOR /AREA LOWER LEVEL SHEET NUMBER FP -01 2 of 3 BY PLU CONTR DINING AREA LEISURE LOF UPPER FLOOR PLAN SCALE : 1/4" =1'-0 SPRAY RIGID FOAM INSULATION BY OTHERS 7I I1 NO - BLOCK FASTENER CPVC PIPE TJI JOIST PIPE TENT INSULATION DETAIL #1 SCALE : N.T.S. BLOWN -IN INSULATION ABOVE BATT INSULATION BY OTHERS BATT TYPE INSULATION COLD SPACE TRUSS CHORD OR JOIST GYPSUM BOARD CEILING —I PIPE SHALL BE REQUIRED TO REMAIN ON A 2" CENTERLINE ON THE TOP OF THE BOTTOM TRUSS CORD ALLOWING FOR TENTING AND SHALL HAVE PRIORITY OVER OTHER TRADES. ADEQUATE INSULATION BY OTHERS HANGER SPACING LEGEND NOMINAL PIPE SIZE (IN.) 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" STEEL PIPE SCH 40, SCH 10, DF,EF N/A 12-0 12-0 15-0 15-0 15-0 15-0 15-0 15-0 15-0 THREADED LIGHTWALL N/A 12-0 12-0 12-0 12-0 12-0 N/A N/A N/A N/A COPPER 8-0 8-0 10-0 10-0 12-0 12-0 12-0 15-0 15-0 15-0 CPVC 5-6 6-0 6-6 7-0 8-0 9-0 10-0 N/A _ N/A N/A PER NFPA 13 9.2.2.1 (A) ARMOVER/DROP Hydraulic Information Remote Area 01 OCCUPANCY CLASSIFICATION Residential 18X18 DENSITY 0,050gpm/ft2 for 900.00ft2 (Actual 292.63ft2) TOTAL HOSE STREAMS 0.00 TOTAL HEADS FLOWING 2 TOTAL WATER REQUIRED 40.01 TOTAL PRESSURE REQUIRED 61.755 BASE of RISER (gpm) 40.01 BASE of RISER (psi) 61.755 SAFETY MARGIN (psi) +68.148 (52.5%) DROP DETAILS SCALE : N.T.S. PIPE TENT INSULATION DETAIL #2 SCALE : N.T.S. STAND OFF HANGER INSUALTION BY OTHERS VAPOR BARRIER STAPLED #10x1" HEX HEAD, CAP SCREW COMPOSITE WOOD I -JOIST GYP. BOARD/ T&G CEILING 10d NAIL (TYP.) WOOD BLOCKII\ TJI SPACE SEMI-REC. PENDENT SPRINKLER MINIMUM DISTANCES FOR TEMPERATURE RESIDENTIAL SPRINKLERS HEAT SOURCE 165 DEGREE 200 DEGREE SIDE OF OPEN OR RECESSED FIRE PLACE 36 in 12 in FRONT OF RECESSED FIREPLACE 60 in 36 in COAL -OR WOOD BURNING STOVE 42 in 12 in KITCHEN RANGE 18 in 9 in WALL OVEN 18 in 9 in HOT AIR FLUES 18 in 9 in UNINSULATED HEAT DUCTS 18 in 9 in UNINSULATED HOT WATER PIPES 12 in 6 in SIDE OF CEILING OR WALL MOUNTED HOT AIR DIFFUSERS 24 in 12 in FRONT OF WALL MOUNTED HOT AIR DIFFUSERS 36 in 18 in HOT WATER HEATER OR FURNACE 6 in 3 in LIGHT FIXTURE OW -250W 6 in 3 in PER NFPA 13D TABLE 7.5.5.3 PIPE TENT INSULATION DETAIL #3 SCALE : N.T.S. G WASHIMC.TON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTI°N SPRINKLER SYSTEMS Erin Clayton 7544-0817-C Level 3 Glacier Fire Protection, L.L.C. GLACIFP834MJ 08/23/2017 Sprinkler Legend a) n C O Q N U O U E O N (1) 1 a) CL a) a) 0 111 a) 0 L O 0 (Ts LL rn 0 N0 C (l3 C� d) O 6) 'd. 0 LL tt G5-56 DRY 0 Z Manufacturer a) 0) NORTH CO CO rn UPPER LEVEL SPRINKLER PLAN GLACIER FIRE PROTECTION LLC PO BOX 7980 BONNEY LAKE, WA 98391 P: (253) 501-7558 www.glacierfireprotection.com GLACIFP834MJ 0 2 4 6 8 10 12 SCALE: 1/8" =1'-0" DRAWN BY: ERIN CLAYTON REVISIONS NO. DESCRIPTION A CITY APPROVAL /3\ DATE: 08/24/17 CONTRACT #: 40002 FLOOR /AREA UPPER LEVEL SHEET NUMBER FP -02 3 of 3