Loading...
HomeMy WebLinkAboutPP - 16436 53RD AVE S - UNKNOWN - PERMITS AND PLANS16436 53RD AVE S ASSOCIATED PERMITS 14-5-268 D14-0354 INSPECTION NUMBER INSPECTION RECORD Retain a copy with peit 0 \4c -63 59' (k -g5 -2.b2 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Proje d\40k- v r N� , �„��C' Type of Inspection: ,(„„_,..,-- Address: Suite #: 1,L43(40 53 PLS Occupancy Type: Contact Person: Special Instructions: Phone No.: 52tApproved per applicable codes. Corrections required prior to approval. COMMENTS: oVc CF11 b -{-6 0 \ DIP c*, Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector Date: -1 cbVs Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 3 INSPECTION NUMBER INSPECTION RECORD Retain a copy with per P-6 PERMIT iv- s- a -s PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: L/ 1,\14- •-'•(.-e..A/fr - V4,4>v e or freac Typ4 of Insp ctign: (/ t 1 r,M t - Address: ,/ co se s-- 3 0 S Suite #: Contact Person: Special Instructions: Phone No.: GL—A pproved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: /fit-. cv-- �-2__ Date: eyb/f s----- Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with , it A0 �Ft PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Pr jest: ��q' C Qv ._:\L 2 YLe c' Tice of Inspection: '1�2Me.L, cn G "1" Address: Suite #: I (r3 t0 ay -- 5� -- PL. S Contact Person: Pre -Fire: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: ` Pre -Fire: Permits: Occupancy Type: *o;.5 R-c-S.I lab Rs"' z1c c - g..,; A,..,,kL Q 1. (b ? PsiQom- `�`bv rvs..,�, - t % 4�0.,) \ c� .5 c?Q ak Z ‘ow \ . S G Q INS , 4y \cam c.5•73.-\..\ a.., n eiktsi s cls :s Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 51 Date: 0W\% Hrs.: \ 3 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 7796400130 Site Address: 16436 53rd PL S Tukwila, WA 98188 Suite Number: N/A Floor: ALL Tenant Name:same as owner Property Owner's Name:Chaffeur-Vertner Mailing Address: 16436 53rd PL S Tukwila, WA 98188 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Matthew Steele Day Telephone: (425) 271-5598 New Tenant? 0 -Yes ❑ - No Company Name: Moore Fire Protection Mailing Address: 14401 Issaquah -Hobart Rd SE ste201 E-mail Address: Matthew@moorefire.com Issaquah WA 98027 City State Zip Fax Number: (425) 369-6899 Valuation of Project (contractor's bid price): $ 3,975.00 Scope of Work (please provide detailed information): Install an Automatic Residential Fire Sprinkler System in the above new residence, as per NFPA 13D PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORI D ENT: "1 Signature: Print Name: tile\ L tL¢til Plan Permit App.doc Date: 1 i / 2.-/N Day Telephone: .ht�{ _ LR Z7 1' S 91 S 5/14/10 TFD FP Form 8 MUM FRONT PORCH NO AS. PER NFPA 13D 8.3.6 (TYP). C� • NO AS. (TYP). BEDROOM 1 NO AS. PER NFPA 13D 8.3.3 (TYP). NO AS. PER NFPA 13D 8.3.2 (TYP). MASTER BEDROOM • BEDROOM 2 1 NO AS. PER NFPA 13D 8.3.3 (TYP). 102 COVERED PATIO NO AS. PER NFPA 13D 8.3.6 (TYP). 1-1 • NO AS. PER NFPA 13D 8.3.3 (TYP). NO AS. (TYP). 1W' POLY UNDERGROUND CONTINUES 110' TO 3/4" DOM/FIRE METER AT STREET. CLOUD DENOTES 2 MOST DEMANDING HEADS IN A SINGLE COMPARTMENT CALCULATED AT 16'-0" X 16'-0" SPACING. MIN. REQUIRED FLOW: 13 GPM PER HEAD. SYSTEM PRESSURE DEMAND: 55.9 PSI. EXCESS PRESSURE: 66.4 PSI. 0 DOTTED LINE DENOTES MIN. DISTANCE FROM HEAT SOURCE TO ORD. TEMP. SPRINKLER I` it GARAGE NO AS. PER NFPA y.Y db relit/1%-A . low (2"(iLtel--t ) r RISER LOCATION. SEE DETAIL THIS PAGE. GREAT ROOM Without Comments As Not in Red 0 Per The i 3e Ache Letter plans have be -,e -,n reviewed by The Tukwila Fire +Irian E3ureatl for conformance with current City Lrcis. Accebt'anc., subject. to errors and which do not authorize violations of adopted ,6F,rdS and ordsr;a01,::e , 'The responsibility for the .vlacy of c:esicrt r . ctali f- with tile designer. cleif i, o s _• { tiikkli s to S:_I e G: drawings eftef t rtO will voi : `.' C ° iGc +t ' %n Alii require a a e v! tt " �' j ti"j t'r r :SS,t.9s.,; cent approv<: ;��i�tli:tai of r.. ..._ � . . :al acceptance i n :robiee U• ii wici rest and inspection I Ie Tukwila Fire Prevention bureau. {rte: 11^ 0I '(`( ov: *1-61-6.1M2 LIODVOIS.,'i JO UM0r, --n s laj s appe. pen puf 'ONi!+tL Fed i'sp. *4.5 51 y MAIN FLOOR PLAN SCALE: 1/4" = 1' - 0'2 10'-0 0 1 o% A LIST OF APPROVED PRODUCTS FOR USE WITH BLAZEMASTER CPVC PIPE IS INCLUDED WITH THE PRODUCT SPECIFICATIONS BOOKLET. FOR A COMPLETE AND UP-TO-DATE PRODUCT SEARCH, PLEASE GO ONLINE TO <http://www.lubrizol.com/CPVC/ChemicalCompatibilityFinder.html> MIIII Ell MI EE Ell Ell =I En Ell INS rail 12 AMIN 1 U 1 JI. 8.3 LOCATION OF SPRINKLERS 8.3.1: SPRINKLERS SHALL BE INSTALLED IN ALL AREAS WITH THE FOLLOWING EXCEPTIONS: 8.3.2: SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 SQ.FT. AND LESS. 8.3.3: SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES 24 SQ.FT OR LESS WHERE THE LEAST DIMENSION DOES NOT EXCEED 3'-0" AND THE WALLS AND CEILING ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED COMBUSTIBLE MATERIALS AS DEFINED IN NFPA-220. 8.3.4: SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES, OPEN ATTACHED PORCHES, CARPORTS, AND SIMILAR STRUCTURES. 8.3.5: SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS, PENTHOUSE EQUIPMENT ROOMS, ELEVATOR MACHINE ROOMS, CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT, FLOOR/CEILING SPACES, ELEVATOR SHAFTS, CRAWL SPACES, AND OTHER CONCEALED SPACES NOT USED OR INTENDED FOR LIVING PURPOSES. 8.3.6: SPRINKLERS SHALL NOT BE REQUIRED IN COVERED, UNHEATED PROJECTIONS OF THE BUILDING AT ENTRANCES/EXITS AS LONG AS THE DWELLING UNIT HAS ANOTHER MEANS OF EGRESS. 8.3.7: SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS OF 100 CUBIC FEET OR LESS WHERE THE FLOOR UNDER IS PROTECTED. 8.3.8: SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS WHERE THERE ARE NO DOORS OR UNPROTECTED PENETRATIONS INTO THE DWELLING UNIT. HYDRAULIC SYSTEM LOCATION: NO. OF SPRINKLERS: COVERAGE PER SPRINKLER: DESIGN DENSITY: AREA OF DISCHARGE: GPM DISCHARGE: RESIDUAL PRESSURE AT BASE OF RISER: STATIC PRESSURE: RE FIRE PROTECTION CHAFFEUR-VERTNER RES. 2 256 .05 512 26.4 66.4 122.5 MOORE FIRE PROTECTION 14401 ISSAQUAH-HOBART RD ISSAQUAH, WA. 98027 (425) 271-5598 FAX (425) 369-6899 MIN. R-7 INSULATION BATE OVER PIPE AND SECURED TO ROOF TRUSS IF BLOWN IN INSULATION IS SED. -SPRINKLE'` BRANCH LINE —UNIT SPACEPENDANT SPRINKLER HEAD TYP. ATTIC INSULATION DETAIL SCALE: NONE FIRE FLOW INFORMATION RECEIVED FROM TEYA HILLERMAN AT HIGHLINEWATER ON OCT 29TH 2014 STATIC PRESSURE 122.46 psi AVAILABLE FLOW 2738.23 gpm RESIDUAL PRESSURE 20.00 psi SECTION CUT SCALE: 1/4" = 1' - 0" AHJ: TUKWILA FIRE MARSHAL NFPA 13D (2013 ED.) SYSTEM DESIGN MAX. RES. PENDENT HD. SPACING 16'-0" X 16'-0" 256 SQ.FT. PER HD. TOTAL MAX. PARCEL NO. 779640-0130 LEGAL DESCRIPTION SILVERVIEW TGW UND INT IN TRACT A NOTES: RESIDENTIAL SPRINKLERS ON SPACING UNLESS OTHERWISE NO RESIDENTIAL SPRINKLERS NOTED. THIS PROJECT ARE CALCULATED AT A MAXIMUM 16'-0" X 16'-0" NOTED. ARE TO BE MORE THAN 8'-0" OFF ANY WALL UNLESS OTHERWISE NO RESIDENTIAL SPRINKLERS IN THE SAME COMPARTMENT ARE TO BE MORE THAN 16'-0" APART MAXIMUM. NO RESIDENTIAL SPRINKLERS ARE TO BE CLOSER TOGETHER THAN 9'-0" MINIMUM UNLESS THE FRAME STRUTS ARE PARALLEL. THEN 8'-O" IS THE MINIMUM. ALL CPVC PIPE IS TO BE SUPPORTED PER MANUFACTURERS SPECIFICATIONS AND IS TO BE SECURED TO PREVENT LATERAL MOVEMENT. PIPE IS TO BE SECURED TO PREVENT SPRINKLER HEAD MOVEMENT. ALL CPVC WET SYSTEM PIPING LOCATED IN ATTIC SPACES AND EXTERIOR WALLS SHALL BE PROTECTED FROM EXPOSURE TO FREEZING TEMPERATURES WITH BATT. TYPE INSULATION (MIN.R-7) INSULATION IS TO PROVIDE ADEQUATE PROTECTION ABOVE / OUTSIDE, THE PIPING AND IS TO BE SECURED TO PREVENT THE ACCUMULATION OF INSULATION BETWEEN THE HEATED BUILDING CAVITY AND THE SPRINKLER PIPING. BLOWN IN TYPE INSULATION IS NOT ACCEPTABLE FOR THIS PURPOSE. ALL INSULATION AND ITS INSTALLATION IS TO BE BY OTHERS. MOORE FIRE PROTECTION'S WARRANTY OF WORK DOES NOT COVER ANY DAMAGE DUE TO FREEZE RELATED PROBLEMS. PIPING IS TO BE MAINTAINED AT 40 DEG. MINIMUM AT ALL TIMES BY OTHERS. MOORE FIRE PROTECTION SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE SPRINKLER SYSTEM OR ANY APPURENANCES THEROF. OWNER IS RESPONSIBLE FOR THE PERIODIC INSPECTION, TESTING AND MAINTENANCE OF THE WATER BASED FIRE PROTECTION SYSTEM(S) IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 25. Hanger No. 23. Pipe Strap Wood Screw #18 x 1.5" Pipe / / / / i / / / / / / / / / //// //// //// / / / / / / / / / / / / / / TYP.FIG #23 CPVC HANGER DETAIL SCALE: NONE MAXIMUM SUPPORT SPACING FOR CPVC PIPING PIPE SIZE 3/4" 1" 1-1/4" 1-1/2" 2" FEET METER 5-1/2 (1.7)6 .8 6-1/2 (2.0) 7 (2.1) 8 (2.4) ■ 1710. 131111111;1:71111111111111 PLUMBER TO 9 17 I E 1 MALE $7 ' !::I►] itift '1 i 11 1 . THREADED ADAPTER @ 1'-0" AFF AND O'-6" FROM WALL. WET PIPE RISER DETAIL SCALE: NONE WET RISER ASSEMBLY LIST NO. ITEM 1 11/4" POLY UG RAN FROM NEW 3/4" DOM/FIRE METER 2 11/4" MAIN SUPPLY SHUTOFF 3 1h/4"X1"X1/2"REDUCING TEE SPLIT TO DOM. LINE 4 DOMESTIC BALL SHUTOFF BY OTHERS 5 11/4" TYPE L COPPER PIPING BY OTHERS 6 1" APOLLO DC4A DOUBLE CHECK VALVE ASSEMBLY 7 1" DYNA-THREAD PIPING WITH C.I. FITTINGS 8 POTTER MODEL VSR S FLOW SWITCH W/ RETARD 9 300# WATER GAUGE WITH 1/2"X 1/4" BUSHING 10 1" COMBINATION MAIN DRAIN INSPECTOR'S TEST 11 1" X 1/2" GALV. 45 PIPED TO EXTERIOR OF BUILDING 12 BROKEN SPKR. HD. TO SIMULATE SPKR. FLOW Hanger FIG.# 28M Stand-off Pipe Hanger Pipe Wood Screw #18 x 11/2 Standoff Pipe Hanger / / / / / / / / / / / / / / / ///////// //// / // ///// // / Wood Joist, Beam or Deck TYP.FIG #28M CPVC HANGER DETAIL SCALE: NONE 3/4" DOM/FIRE rETERAT TREET 71j SITE MAP SCALE: NONE RISER LOCATION PAID NOV .1.7 411 .TUK W ILA FIRE cc A9-15% DRAWING NO. 11 1 0 Revisions Head Count M Cy 160 DEG F TYCO LFII RES. QR. WHITE CONC. SSP K=4.9 TOTAL HEADS FOR PROJECT: o. State license ert Parcel: 779640-0130 B. BERNARD uJ (3 0 .