Loading...
HomeMy WebLinkAboutPP - 16659 53RD AVE S - UNKNOWN - PERMITS AND PLANS16659 53RD AVE S ASSOCIATED PERMITS 17-5-135 D16-0330 CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION King Co. Assessor's Tax No.: 5314:120b13 5 Site Address: \ 66S°1 511z° Ave. 5 Suite Number: Floor: Tenant Name: New Tenant? ❑ - Yes ❑ - No Property Owner's Name: DOAN) Irk -WV $VU Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: JON g1 -M.11 Day Telephone: CZ53) 82( - (Docket Company Name: F1¢E `59e.1NbLLE.¢s IIJC Mailing Address: '521) 45114 ST I? 1 SkATE 102 'SvMNet. W A e18S°10 City State Zip E-mail Address: 3OI4a D Fite Pe1NKtarfirs% Nc. CAM Fax Number: Contractor's City of Tukwila NICET III number: tiSt3- CA -0_ - I~ Business License number: BUS- 0°1°14435 Total number of new/relocated devices or sprinkler heads: 31 Valuation of Project (contractor's bid price): $ -4(920 Scope of Work (please provide detailed information): 1.l ENA) WET SPQIN LLMAL SY5t1=M FbQ eEStD64C..t= Pee NF Pp. 130 PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. [ HEREBY CERTIFY THAT [ HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Plan Pcnnit App.doc Day Telephone: Date: 111- I 2orT 0253) 82` - 00ck01 8/22/14 TFD FP Form 8 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Niii,J + ��/S C Type of Inspection: Address: �/ Suite #: �j fp) Contact Person: ,J,-1-7___ /9p,(z- Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: 5 p.,- ( wia.Erz- ,J,-1-7___ /9p,(z- Permits: Occupancy Type: F /jam A^/' ,,;�� 7-2-6,./47-4 p �z RO,2 dS7 ic7# ,..,64-15 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: r S4— Date: f /2 .Nrs.: / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:(fl/ 5 E Type of Inpaction: Address: ii Suite #: l �p ontact Person: > ,/C-(Cfrita-b Special Instructions: Phone No.: 746- Permits: 5 5--- 6135 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: r- Pr OS Serer. i& - - j)w►7$ GNI s7 Tr- Hood & Duct: Monitor: /kik 1` U,5'T - %-f N 4 7Ty-ser Fj g -LL._ Permits: Occupancy Type: P6e7-' ,*D®p--SS ge-7144ve- 5e7r2_1 k t q'%Z C' Vp\ism--64._ ` 124i'►A 1J Th',2 ( 'L C' )T— Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: i Inspector: .]%1 5"4 Date: /211gh q_ Hrs.: I $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 1 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /7-5- 135 - Dai -ago PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 5.27 444e Sprinklers: Type of Inspection: / obb Co ve," gLit ek_ell-- Address: Suite #: 57 A96, 5 3 eS Con act Person: Special Instructions: Phone No.: KApproved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: ,-Y-T-e7/111'1 pe --42- Cd -eN2.44)r.R.v.12.( Pre -Fire: Permits: Occupancy Type: - / dry Pietcs-c----D ZL€G >, ' Z A2 -ds iC Ed S eG ods- l (%j14 ‘' r` (L! IrA / 3 , ( '--'- e"--55 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: i Inspector: ,033 Date: g//?ih -7 IHrs.: , O $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER AND IS THE MINIMUM FASTENER SIZE ACCEPTABLE CPVC DOUBLE FASTENER STRAP TYPE HANGER TOLCO FIG. #24 HANGER TYPE CP NTS HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER AND IS THE MINIMUM FASTENER SIZE ACCEPTABLE "OFFSET" HANGER & RESTRAINER FOR CPVC AND IPS PIPE TOLCO FIG. #28M HANGER TYPE CP NTS BUILDING SECTION A HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER AND IS THE MINIMUM FASTENER SIZE ACCEPTABLE "DOUBLE OFFSET" HANGER & RESTRAINER TOLCO FIG. #29 HANGER TYPE CP NTS 0 EINAZ Without Ac Notei . Per Tl 1,., These plans have been rcvia,vt a `, Tukwila Fire P' :vention Bureau for conforr'nan'"e . th current City ?l1C13:"ds. Acceroce is SI/(lje', t , : fl(`:r arid :-rlllSsIans vdhic ; on not auchorl<:( „a I� r of adopted rEda'''()s an() oci,,i4i aces. The ;e:,:t,m"sil?,'flty for the (Nut -3(y o r?t: 4 s 171:6! v Vali:!'? • Idons, CIS" E i Y f ; !- I:avision re E.! 'i r .wingls after date.';,:,ilii U'it�::� 'r'Ii:': s ;::�' eprarlrr' ; nO `'{II require a ubmi t ' fAT 617,�,�ettapproval. F-1nr i acce) i':rnze. ".::: D, ct to field test and Inspection by 1 e Tuk wiia FV ', ..fentlon Bureau. Date: 6y: Y.- Flo-, k t3 1 t-ufl-) 1t)15-" rev, FPI SCALE: NTS HYDRAULIC DESIGN INFO THIS SYSTEM IS THIS SYSTEM IS NOT HYDRAULICALLY DESIGNED HYDRAULICALLY DESIGNED - FLOW TEST - STATIC: - 128 PSI RESIDUAL: - 20 PSI GPM FLOWING: - 1500 GPM DATE & TIME: - 6/21/17 - SYSTEM DESIGN - REMOTE AREA: AREA 1 DENSITY: .05 GPM / SQ FT MAX AREA/ HEAD: 16' x 16' K -FACTOR: 4.9K REMOTE AREA #1 THIS AREA HAS BEEN HYDRAULICALLY CALCULATED TO DELIVER A RESIDENTIAL COVERAGE (NFPA 13D) OF: 15 GPM @ 9.4 PSI USING 16' x 16' HEAD SPACING SYSTEM DEMAND: 30.5 GPM@ 50.0 PSI FLEX)F: >,R; .:::>. DINING ROOM GUEST BEDROOM FAMILY ROOM Yi EPA.Ar.1? KITCHEN BATH --_ PANTRY BATH i 1 REMOTE AREA 1 Residential•0.05gpmfft2 for 181.04ft2 LIVING ROOM MAIN FLOOR -SPRINKLER PIPING PLAN SCALE: 1/8" = 1'-0" ATTIC INSULATION (BY OTHERS). USE BATT TYPE INSULATION FOR TENTING CPVC FIRE SPRINKLER PIPE BOTTOM CHORD OF TRUSS TENT FIRE SPRINKER PIPE BEFORE INSULATING ATTIC (BY OTHERS). USE BATT TYPE INSULATION FOR TENTING. GWB CEILING WET PIPE FREEZE PROTECTION DETAIL NTS •s UM iLA FIR.. DEP,'''.' TM> NT Pteet e call l 2OG,-% .544O7 and give this Fre Permit it No. 7 - and pec address for phut- down ut � own or nsstoi" t§§on approval, 1% 0-4 ECH 40 TxG 1%SXGADAPTER 1% FLEX COUP (2 FSI START POINT 1% 0-4 SS GXT 1% FLEX COUP 1%0-4 SS GXT RISER LEGEND 1 - 1W WATER SUPPLY LINE 2 - 1%" AMES 2000B BACKFLOW 3 - WATER FLOW ALARM SWITCH WIRED TO ALARM BELL 4 - WATER PRESSURE GAUGE 5 - 1" VALVE FOR DRAIN 6 - 1" DRAIN LINE PIPED TO EXTERIOR OF BUILDING 7 - 6" ALARM BELL INSTALLED ON EXTERIOR OF BUILDING RISER NOTES 1 - ALL CONTROL VALVE HANDLES TO BE REMOVED AND PLACED IN HEAD BOX AT TIME OF FINAL 2 - WIRING OF FLOW SWITCH AND BELL TO BE BY OTHERS 3 - 11/2" SUPPLY LINE TO BE PROVIDED BY OTHERS REMOTE AREA #2 THIS AREA HAS BEEN HYDRAULICALLY CALCULATED TO DELIVER A RESIDENTIAL COVERAGE (NFPA 13D) OF: 13 GPM @ 7 PSI USING 16' x 16' HEAD SPACING SYSTEM DEMAND: 26.3 GPM@ 57.3 PSI REMOTE AREA 2 Res dential•0.05gpmfft2 for 247.83f12 MASTER BEDROOM CUPPER FLOOR -SPRINKLER PIPING PLAN SCOPE OF WORK: INSTALL NEW NFPA 13D FIRE SPRINKLER SYSTEM THROUGHOUT NEW RESIDENCE. GENERAL NOTES: 1. IT IS THE RESPONSIBILITY OF THE OWNER TO MAINTAIN THE INTEGRITY OF THE SPRINKLER SYSTEM. 2. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL AND/OR FM APPROVED. 3. ALL SYSTEM PIPING SHALL BE TESTED AT STATIC PRESSURE PER NFPA 13D. 4. PIPE HANGER AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA #13D (2013). 5. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM. 6. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER AND/OR HIS STRUCTURAL REPRESENTATIVE. 7. ALL FIRE ALARMS, WIRING AND MONITORING ARE TO BE INSTALLED BY OTHERS. DESIGN NOTES: 1. RISER ASSEMBLY / PUMP AND TANK TO BE LOCATED IN THE GARAGE (FSI START POINT). 2. SYSTEM TO BE DESIGNED IN ACCORDANCE WITH NFPA #13D SINGLE FAMILY RESIDENCE. 3. PLAN SUBMITTAL TO AND APPROVAL BY CITY OF TUKWILA. 4. MATERIALS PER NFPA#13D STANDARDS AS SELECTED BY FSC 5. TESTING PER NFPA #13D AND CITY OF TUKWILA. 6. TYPICAL HANGERS TO BE TOLCO FIG. 24, 28M & 29 UNLESS NOTED OTHERWISE FIELD NOTES: 1. ALL NEW PIPE IS TO BE CPVC. 2. ALL NEW FITTINGS ARE TO BE CPVC. 3. DESIGN CRITERIA TO BE BASED ON NFPA 13D: A. SPRINKLER SPACING NOT TO EXCEED (20' x 20') OR (10') OFF OF WALLS MAXIMUM. B. MINIMUM PRESSURE AND FLOW FOR SPRINKLERS SPACED 20' x 20' = 20 GPM 16.7 PSI. NEW HOUSE 1'/x" WATER SUPPLY LINE (INSTALLED BY OTHERS) I NEW DRIVEWAY • i SITE PLAN SCALE: NTS 6" ALARM BELL INSTALLED ON EXTERIOR OF BUILDING (WIRING BY OTHERS) METER S 3fN3AV Gass VICINITY MAP PA JUL, « 7au TLUKW1 FIRE WA CL# FIRESI"988RJ 1524 45th Street East, Suite 102 Sumner, WA 98390 (253) 826-0099 www.tiresprinklersinc.com DRAWN BY: J HENSLEY REVIEWED BY: MPM DATE: 6/21/17 SCALE: AS NOTED AHJ: CITY OF TUKWILA REVISIONS: REV# DATE BY DESCRIPTION STAMP': WASH ty w; rota STATE CERTIFICATE of coMPETENCy FIRE PROTECTION SPRINKLER STETTER* Michael Paul Moffett 4513-0612-C Level 3 Fire Sprinklers Incorporated FIRESI'988RJ $SIgnatUra SPRINKLER LEGEND N M w z U z u_ m U ❑ 2 F- n - 2 u0 u, 0 N 1- u_ u_ w a ❑ 0- U z 0 0 D- U z 0 U DRY PNDNT D - w rt 0 ce 0 0 z 0) v 0) u-) MANUFACTURER O > O z O U O TOTAL THIS SHEET = 16659 TUKWILA RESIDENCE CONTRACT WITH: AMERICAN PRESTIGE HOMES P.O. BOX 46002 SEATTLE, WA 98146 SAN STEVENS (206) 853-4525 HANGER LEGEND: CP CPVC HANGER DRAWING SYMBOLS: s - FLEXIBLE GROOVED COUPLING - WELDED PIPE TAG ofsam - RIGID GROOVED #1 - BRANCHLINE COUPLING NUMBER ovad:. - PIPE HANGER (SEE CHART) SEISMIC BRACE * 10'-10' 9-0 PIPE SIZE & LENGTH CUT FF - ELEVATION DATUM O - HYDRAULIC NODE * 0'-10° TS - CENTERLINE OF PIPE TO DECK JOB NUMBER: 7436 SHEET NUMBER: FP1of1