HomeMy WebLinkAboutPP - 16659 53RD AVE S - UNKNOWN - PERMITS AND PLANS16659 53RD AVE S
ASSOCIATED PERMITS
17-5-135 D16-0330
CITY OF TUKWILA
FIRE MARSHAL'S OFFICE
206-575-4407
FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
SITE LOCATION
King Co. Assessor's Tax No.: 5314:120b13 5
Site Address: \ 66S°1 511z° Ave. 5
Suite Number: Floor:
Tenant Name: New Tenant? ❑ - Yes ❑ - No
Property Owner's Name: DOAN) Irk -WV $VU
Mailing Address:
City State Zip
CONTACT PERSON -if there are questions about the submittal.
Name: JON g1 -M.11 Day Telephone: CZ53) 82( - (Docket
Company Name: F1¢E `59e.1NbLLE.¢s IIJC
Mailing Address: '521) 45114 ST I? 1 SkATE 102 'SvMNet. W A e18S°10
City State Zip
E-mail Address: 3OI4a D Fite Pe1NKtarfirs% Nc. CAM Fax Number:
Contractor's City of Tukwila
NICET III number: tiSt3- CA -0_ - I~ Business License number: BUS- 0°1°14435
Total number of new/relocated devices or sprinkler heads: 31
Valuation of Project (contractor's bid price): $ -4(920
Scope of Work (please provide detailed information): 1.l ENA) WET SPQIN LLMAL SY5t1=M FbQ
eEStD64C..t= Pee NF Pp. 130
PERMIT APPLICATION NOTES
Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
[ HEREBY CERTIFY THAT [ HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature:
Print Name:
Plan Pcnnit App.doc
Day Telephone:
Date: 111- I 2orT
0253) 82` - 00ck01
8/22/14 TFD FP Form 8
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
206-575-4407
Project: Niii,J + ��/S C
Type of Inspection:
Address: �/
Suite #: �j
fp)
Contact Person:
,J,-1-7___ /9p,(z-
Special Instructions:
Occupancy Type:
Phone No.:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Sprinklers:
Fire Alarm:
Hood & Duct:
5 p.,- ( wia.Erz-
,J,-1-7___ /9p,(z-
Permits:
Occupancy Type:
F /jam A^/'
,,;�� 7-2-6,./47-4
p
�z
RO,2
dS7
ic7# ,..,64-15
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector:
r
S4—
Date: f
/2
.Nrs.: /
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word/Inspection Record Form.Doc
3/14/14
T.F.D. Form F.P. 113
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
206-575-4407
Project:(fl/ 5 E
Type of Inpaction:
Address: ii
Suite #: l �p
ontact Person:
> ,/C-(Cfrita-b
Special Instructions:
Phone No.:
746-
Permits:
5 5--- 6135
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Sprinklers:
r-
Pr OS Serer. i& - - j)w►7$ GNI s7 Tr-
Hood & Duct:
Monitor:
/kik
1` U,5'T - %-f N 4 7Ty-ser Fj g -LL._
Permits:
Occupancy Type:
P6e7-' ,*D®p--SS
ge-7144ve- 5e7r2_1 k t q'%Z C' Vp\ism--64._ ` 124i'►A
1J
Th',2 ( 'L C' )T—
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
i
Inspector:
.]%1
5"4
Date: /211gh q_
Hrs.: I
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word/Inspection Record Form.Doc
3/14/14
T.F.D. Form F.P. 113
1
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
/7-5- 135 -
Dai -ago
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
206-575-4407
Project:
5.27 444e
Sprinklers:
Type of Inspection:
/ obb Co ve," gLit ek_ell--
Address:
Suite #: 57
A96,
5 3
eS
Con act Person:
Special Instructions:
Phone No.:
KApproved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Sprinklers:
Fire Alarm:
Hood & Duct:
,-Y-T-e7/111'1 pe --42- Cd -eN2.44)r.R.v.12.(
Pre -Fire:
Permits:
Occupancy Type:
- / dry Pietcs-c----D
ZL€G >, ' Z A2 -ds iC Ed S eG ods- l (%j14
‘' r` (L! IrA / 3 , ( '--'- e"--55
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
i
Inspector:
,033
Date: g//?ih -7
IHrs.:
, O
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word/Inspection Record Form.Doc
3/14/14
T.F.D. Form F.P. 113
HARDENED HEX HEAD SELF THREADING SCREW
IS FURNISHED WITH THE HANGER AND IS THE
MINIMUM FASTENER SIZE ACCEPTABLE
CPVC DOUBLE FASTENER STRAP TYPE HANGER
TOLCO FIG. #24
HANGER TYPE CP
NTS
HARDENED HEX HEAD SELF THREADING SCREW
IS FURNISHED WITH THE HANGER AND IS THE
MINIMUM FASTENER SIZE ACCEPTABLE
"OFFSET" HANGER & RESTRAINER
FOR CPVC AND IPS PIPE
TOLCO FIG. #28M
HANGER TYPE CP
NTS
BUILDING SECTION A
HARDENED HEX HEAD SELF THREADING SCREW
IS FURNISHED WITH THE HANGER AND IS THE
MINIMUM FASTENER SIZE ACCEPTABLE
"DOUBLE OFFSET" HANGER & RESTRAINER
TOLCO FIG. #29
HANGER TYPE CP
NTS
0
EINAZ
Without
Ac Notei .
Per Tl 1,.,
These plans have been rcvia,vt a `, Tukwila Fire
P' :vention Bureau for conforr'nan'"e . th current City
?l1C13:"ds. Acceroce is SI/(lje', t , : fl(`:r arid
:-rlllSsIans vdhic ; on not auchorl<:( „a I� r of adopted
rEda'''()s an() oci,,i4i aces. The ;e:,:t,m"sil?,'flty for the
(Nut -3(y o r?t: 4 s 171:6! v Vali:!'?
• Idons, CIS" E i Y f ; !- I:avision re E.! 'i r .wingls after
date.';,:,ilii U'it�::� 'r'Ii:': s ;::�' eprarlrr' ; nO `'{II require a
ubmi t ' fAT 617,�,�ettapproval.
F-1nr i acce) i':rnze. ".::: D, ct to field test and Inspection by
1 e Tuk wiia FV ', ..fentlon Bureau.
Date: 6y:
Y.- Flo-, k t3 1 t-ufl-) 1t)15-" rev,
FPI
SCALE: NTS
HYDRAULIC DESIGN INFO
THIS SYSTEM IS THIS SYSTEM IS NOT
HYDRAULICALLY DESIGNED HYDRAULICALLY DESIGNED
- FLOW TEST -
STATIC:
- 128 PSI
RESIDUAL:
- 20 PSI
GPM FLOWING:
- 1500 GPM
DATE & TIME:
- 6/21/17
- SYSTEM DESIGN -
REMOTE AREA:
AREA 1
DENSITY:
.05 GPM / SQ FT
MAX AREA/ HEAD:
16' x 16'
K -FACTOR:
4.9K
REMOTE AREA #1
THIS AREA HAS BEEN HYDRAULICALLY CALCULATED TO DELIVER A
RESIDENTIAL COVERAGE (NFPA 13D) OF:
15 GPM @ 9.4 PSI USING 16' x 16' HEAD SPACING
SYSTEM DEMAND:
30.5 GPM@ 50.0 PSI
FLEX)F: >,R; .:::>.
DINING ROOM
GUEST BEDROOM
FAMILY ROOM
Yi EPA.Ar.1?
KITCHEN
BATH
--_
PANTRY
BATH i
1
REMOTE AREA 1
Residential•0.05gpmfft2 for 181.04ft2
LIVING ROOM
MAIN FLOOR -SPRINKLER PIPING PLAN
SCALE: 1/8" = 1'-0"
ATTIC INSULATION (BY OTHERS).
USE BATT TYPE INSULATION
FOR TENTING
CPVC FIRE SPRINKLER PIPE
BOTTOM CHORD OF TRUSS
TENT FIRE SPRINKER PIPE
BEFORE INSULATING ATTIC
(BY OTHERS). USE BATT TYPE
INSULATION FOR TENTING.
GWB CEILING
WET PIPE FREEZE
PROTECTION DETAIL
NTS
•s UM iLA FIR.. DEP,'''.' TM> NT
Pteet e call l 2OG,-% .544O7 and
give this Fre Permit it No.
7 -
and pec address for phut-
down
ut
� own or nsstoi" t§§on approval,
1% 0-4 ECH 40 TxG
1%SXGADAPTER
1% FLEX COUP
(2
FSI START POINT
1% 0-4 SS GXT
1% FLEX COUP
1%0-4 SS GXT
RISER LEGEND
1 - 1W WATER SUPPLY LINE
2 - 1%" AMES 2000B BACKFLOW
3 - WATER FLOW ALARM SWITCH WIRED TO ALARM BELL
4 - WATER PRESSURE GAUGE
5 - 1" VALVE FOR DRAIN
6 - 1" DRAIN LINE PIPED TO EXTERIOR OF BUILDING
7 - 6" ALARM BELL INSTALLED ON EXTERIOR OF BUILDING
RISER NOTES
1 - ALL CONTROL VALVE HANDLES TO BE REMOVED
AND PLACED IN HEAD BOX AT TIME OF FINAL
2 - WIRING OF FLOW SWITCH AND BELL TO BE BY OTHERS
3 - 11/2" SUPPLY LINE TO BE PROVIDED BY OTHERS
REMOTE AREA #2
THIS AREA HAS BEEN HYDRAULICALLY CALCULATED TO DELIVER A
RESIDENTIAL COVERAGE (NFPA 13D) OF:
13 GPM @ 7 PSI USING 16' x 16' HEAD SPACING
SYSTEM DEMAND:
26.3 GPM@ 57.3 PSI
REMOTE AREA 2
Res dential•0.05gpmfft2 for 247.83f12
MASTER BEDROOM
CUPPER FLOOR -SPRINKLER PIPING PLAN
SCOPE OF WORK:
INSTALL NEW NFPA 13D FIRE SPRINKLER SYSTEM THROUGHOUT NEW RESIDENCE.
GENERAL NOTES:
1. IT IS THE RESPONSIBILITY OF THE OWNER TO MAINTAIN THE INTEGRITY OF THE SPRINKLER SYSTEM.
2. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL AND/OR FM APPROVED.
3. ALL SYSTEM PIPING SHALL BE TESTED AT STATIC PRESSURE PER NFPA 13D.
4. PIPE HANGER AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA #13D (2013).
5. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS
PROTECTED BY A WET PIPE SPRINKLER SYSTEM.
6. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER PIPING IS THE
RESPONSIBILITY OF THE OWNER AND/OR HIS STRUCTURAL REPRESENTATIVE.
7. ALL FIRE ALARMS, WIRING AND MONITORING ARE TO BE INSTALLED BY OTHERS.
DESIGN NOTES:
1. RISER ASSEMBLY / PUMP AND TANK TO BE LOCATED IN THE GARAGE (FSI START POINT).
2. SYSTEM TO BE DESIGNED IN ACCORDANCE WITH NFPA #13D SINGLE FAMILY RESIDENCE.
3. PLAN SUBMITTAL TO AND APPROVAL BY CITY OF TUKWILA.
4. MATERIALS PER NFPA#13D STANDARDS AS SELECTED BY FSC
5. TESTING PER NFPA #13D AND CITY OF TUKWILA.
6. TYPICAL HANGERS TO BE TOLCO FIG. 24, 28M & 29 UNLESS NOTED OTHERWISE
FIELD NOTES:
1. ALL NEW PIPE IS TO BE CPVC.
2. ALL NEW FITTINGS ARE TO BE CPVC.
3. DESIGN CRITERIA TO BE BASED ON NFPA 13D:
A. SPRINKLER SPACING NOT TO EXCEED (20' x 20') OR (10') OFF OF WALLS MAXIMUM.
B. MINIMUM PRESSURE AND FLOW FOR SPRINKLERS SPACED 20' x 20' = 20 GPM 16.7 PSI.
NEW HOUSE
1'/x" WATER SUPPLY LINE
(INSTALLED BY OTHERS)
I
NEW DRIVEWAY
•
i
SITE PLAN
SCALE: NTS
6" ALARM BELL
INSTALLED ON
EXTERIOR OF BUILDING
(WIRING BY OTHERS)
METER
S 3fN3AV Gass
VICINITY MAP
PA
JUL, « 7au
TLUKW1 FIRE
WA CL# FIRESI"988RJ
1524 45th Street East, Suite 102
Sumner, WA 98390
(253) 826-0099
www.tiresprinklersinc.com
DRAWN BY: J HENSLEY
REVIEWED BY: MPM
DATE:
6/21/17
SCALE:
AS NOTED
AHJ:
CITY OF TUKWILA
REVISIONS:
REV#
DATE
BY
DESCRIPTION
STAMP':
WASH ty w; rota STATE
CERTIFICATE of coMPETENCy
FIRE PROTECTION SPRINKLER STETTER*
Michael Paul Moffett
4513-0612-C Level 3
Fire Sprinklers Incorporated
FIRESI'988RJ
$SIgnatUra
SPRINKLER LEGEND
N
M
w
z
U
z
u_
m
U
❑
2
F-
n -
2
u0
u,
0
N
1-
u_ u_
w
a
❑
0-
U
z
0
0
D-
U
z
0
U
DRY PNDNT
D -
w
rt
0
ce
0
0
z
0)
v
0)
u-)
MANUFACTURER
O
>
O
z
O
U
O
TOTAL THIS SHEET =
16659 TUKWILA RESIDENCE
CONTRACT WITH:
AMERICAN PRESTIGE HOMES
P.O. BOX 46002
SEATTLE, WA 98146
SAN STEVENS (206) 853-4525
HANGER LEGEND:
CP
CPVC HANGER
DRAWING SYMBOLS:
s - FLEXIBLE GROOVED
COUPLING
- WELDED
PIPE TAG
ofsam - RIGID GROOVED #1 - BRANCHLINE
COUPLING NUMBER
ovad:.
- PIPE HANGER
(SEE CHART)
SEISMIC BRACE
* 10'-10'
9-0
PIPE SIZE
& LENGTH CUT
FF - ELEVATION
DATUM
O - HYDRAULIC NODE * 0'-10° TS - CENTERLINE
OF PIPE TO
DECK
JOB NUMBER:
7436
SHEET NUMBER:
FP1of1