Loading...
HomeMy WebLinkAboutPP - 16833 53RD AVE S - UNKNOWN - PERMITS AND PLANS16833 53RD AVE S ASSOCIATED PERMITS 12-5-089 D12-077 PW07-142 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit As0°a CITY OF TUKWILA FIRE DEPARTMENT /a-5-aer PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project, 1-r 1)-r. Sprinklers: K,i, JA Type f Inspection: Sr c, w ort-/r;rt ittiviL Address: /4g 3 3 Suite #: �--3 {S Contact Person: Nbre,c,J Go 1 J Special Instructions: Phone No.: Approved per applicable codes. riCorrections required prior to approval. COMMENTS: 5r Np(t - 6 �r-c N — D7C Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: i2,. c "r„t S Date: 7 )g_5' I Z Hrs.: n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with pe PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project:Type -r(.- A� �u to/ /4 of Inspection: 5i° Address: / 68 L Suite #: S3 nv.,2_,s Contact Person: Special Instructions: Occupancy Type: Phone No.: riApproved per applicable codes. 1A/ Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 1-4P /Arem 0J2, 5 '> U e i../v2k-,s N 4/h(K 'rA" . 5& ! 4'cIc1&Le_ oft.' r e it./. -c / _S- Ltl g -/`t 142 fVo14 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: ca --,Date: 71/161 / e- Hrs.: H $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /a - 5 -OST 077 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: ' I�fL <----- pwi //4 Type ofspection: S Address: /49 33 Suite #: 53 S Contact Person: Special Instructions: Occupancy Type: Phone No.: ll -Approved per applicable codes. nCorrections required prior to approval. COMMENTS: Cove- /q/o)/Hti-Ero lc, ? 6-- re, --64-e, Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: i/ , tea— Date: 6/i 9(, L Hrs.: n $100.00 REINSPECTION FEE REQUIRED.. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 1 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: 4,,w1/ Atm gic, otkinur Type f Inspe tion: Address: IL $ 3 3 Suite #: 53 f -ii S . Contact Person /%o /tete Special Instructions: Permits: Phone No.: / b,bo,3-' fb8.5". 0 ----- Approved per applicable codes. Corrections required prior to approval. COMMENTS: Z4- iZtir firivifv.... 0/4 ii — 21.1/ ` 77) P19 u vE /iv Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 4.411A /5//,_ Date: 2/5 /99 Hrs.: / n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** nn King Co. Assessor's Tax No.: 8i 2.52ODL18O Site Address: 1 (ASS SS S 3'°'' A 2, E�-�-, Suite Number: Floor: Tenant Name: New Tenant? ❑ - Yes 1=1- No Property Owner's Name: t i �& 1-10P-1 Mailing Address: p.0. 3 cm i (Ai P1 ct 3,3c36 State Zip City CONTACT PERSON -if there are questions about the submittal. Name: C_Oooj 5i SSDr, Day Telephone: £42S -98l'-0 00 Company Name: tZe,s eS }; re, f p ro{e �- o,i Mailing Address: li l(o°1O 0.3.z c -TH S? Feole->o,c,1 Lila QS0'Z City State Zip E-mail Address: Co eese... 5 SS0,03 ®WS Fax Number: Valuation of Project (contractor's bid price): $ UO. (So Scope of Work (please provide detailed information): -"Tlf.4.: ((k; vn Cly' Ctt nV)-42/" bS A el—p per J FPe4 I 7 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A Signature: RIZED AGENT: Print Name: Si SCoe-N Plan Permit App.doc Date: 11— )2 - Day Telephone: 412s-' gar -0(00 5/14/10 TFD FP Form 8 5 SPRAY RIGID FOAM INSULATION •AFCON #511 HANGER CPVC SPRINKLER PIPE CPVC :SPRINKLER PIPE TO INSTALL A FIRE SPRINKLER SYSTEM INTO SINGLE FAMILY DWELLING IN ACCORDANCE WITH NFPA 13D 2010 AND LOCAL AUTFIORITY. A. THIS FIRE SPRINKLER SYSTEM TO BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 13D 2010 AND LOCAL. AUTHORITY. 1" RESIDENTIAL RISER GAGE, FLOW SWITCH, TEST & DRAIN -MOTTO. SCALE TYPICAL HANGER DETAILS MAXIMUM DISTANCE BETWEEN HANGERS i , • I 1 I 3/4- , 1" 1-1/4II ; i1/20 - 2" ' 2-1 r2- i a 3-1/2 , 1t 1 on...I d . ' . l 4" SIZE (in.) , t t t , STEEL PIPE EXCEPT L z NIA ''. 12-0 1 12-0 '.. 15-0 i 15-0 15-0 I 15-0 ', 15-0 , 15-0 16-0 15-0 15-0 THREA15)ED LIGI-MiVALL THREADED LIGHTVVALL ',, I i . I , • • i t , • 12-0 1 12-0 t NIA ' NIA N/A STEEL PIPE 1 l COPPER TUBE i 8-0 " 8-0 i 10-0 10-0 12-0 12-0 ' 12-0 ' 15-0 15-0 15-0 : 15-0 16-0 ,___........... ___ DETAIL IS SCHEMATIC ONLY. RISER IS CLARITY AND DETAIL INFORMATION. RISER DETAIL SCALE N.T.S. CPV5-6C, ...• ; •.. . , • , 5- 6-0 6-6 7-0 8-0 9-0 : 12-;-0 N/A !- N!A 1\11A NIA N/A • A NIA WI N/A N/A .A , POLYBUTYLENE (IPS) N/A 3-9 4-7 .5-0 5-11 NIA NI 1 POLYBUTYLENE (CTS) 2-11 3-4 3-11 ; 4-5 ; 5-5 N/A I N/A •• NIA ! NIA N/A : N/A Kthout Comments As i\hted in Rod Per The Attached Letter These plans have been by The Tukwila Fire Prevention Bur.--.;eLf frr c;orrri37.ce with current City standards. Acc.:ec:;::::trcc5 is5-.5;•.`niet...t. tr.i. errors and o which do not :..3W.norize violations of adopted standards no cnces. The responsibility for the adequacy of di;'...3i":1;ii i'es•cs totally with the designer, Additions, deiedns or revslons to these drawings after this date will void. thIs ,'-_=•;,...x.-.eptancE.: and wig require a resubmittal of revi9.-d dziwirig&.- for subsequent approval. Final acceptance i to field test and inspection by The Tukvqiia Hre Pre%sfention f-AwtOU, Thic:,VILA, FIRE DEPARTMENT Piase caP 2.065-4407 and give this Fire Permit No. and E.,xart addi'ess for shut- down or restoration approval HANGER NOTES NOTES 1. ALL MATERIAL TO BE UL LISTED. 2. ALL HANGERS TO BE PLACED AND SPACED IN ACCORDANCE WITH NFPA 13D, 2010 ED.: 3. ALL BRANCH LINES TO HAVE A HANGER LOCATED WITHIN 21-0 OF END OF PIPE. P.A 'SITE PURGE CONNECTIONS 0,"1 CHECKED BY: MARK COAD - NICET # 97909 605-721-0485 - OFFICE WESTERN STATES FIRE PROTECTION, CO. 5000 API Road BLACK HAWK, SD 57718 ***VVATER SUPPLY REQUIREMENTS*" BASED ON THE DESIGN FOR THIS AUTOMATIC FIRE SPRINKLER SYSTEM, IT IS THE OWNER'S RESPONSIBILITY. TO r PROVIDE A RELIABLE WATER SUPPLY THAT IS CAPABLE OF MEETING THE MOST DEMANDING AREA. IF THE OWNER CANNOT PROVIDE THIS WATER SUPPLY, A FIRE PUMP AND I: TANK WILL BE REQUIRED TO BE INCORPORATED AS AN ADDITIONAL ITEM NOT CURRENTLY INCLUDED IN THE SCOPE OF WORK PROVIDED BY WESTERN STATES FIRE PROTECTION.' Iris AUTOMATIC SPRINKLER SYSTEM IS SIZED BASED ON IHYDRAULIC CALCULATIONS IN ACCORDANCE WITH THE ,REQUIREMENTS OF NFPA 13D 2010 EDITION. HYDRAULIC 'CALCULATIONS ARE BASED ON THE REMOTE 2 HEADS OPERATING AT A MINIMUM DESIGN DENSITY OF 0.05 :'.9PM/SQFT AND IN ACCORDANCE WITH THE SPRINKLER LISTING. THE BASIS OF DESIGN ASSUMES A RESIDENTIAL LIVING CONDITION. CARE SHOULD BE TAKEN TO INSTALL NAILER PLATES TO COVER ALL PIPE SUBJECT TO DAMAGE FROM SCREW AND 11 NAIL PENETRATIONS. PROPER PROTECTION OF PIPE FROM DAMAGE ISA REQUIREMENT OF NFPA 13D AND THE MANUFACTURERS LISTING. Calc Tag OCCUPANCY CLASSIFICATION Residential TOTAL HOSE STREAMS 5.00 TOTAL HEADS FLOWING 2 K -FACTOR 3 TOTAL WATER REQUIRED 25.03 TOTAL PRESSURE REQUIRED 60.424 SAFETY MARGIN - PSI +67.828 (52.9%) Supply FIow . . Test Data Static Pressure 129.000 Residual Pressure: 55.000 Flow 300.00 B. ALL PIPE AND MATERIALS PER NFPA 13D 2010. C. ALL PIPING TO BE ATTACHED TO STRUCTURAL FRAMING MEMBERS WITH APPROVED CPVC ATTACHMENTS. D. ALL PIPE DIMENSIONS ARE CENTER -TO -CENTER. E. ALL PIPE TO BE 1" OR GREATER CPVC PIPE. F. ALL PIPE TO BE JOINED IN ACCORDANCE WITH NFPA 13D G. ALL HANGERS TO SIZED AND SPACED PER NFPA 13D H. WESTERN STATES FIRE PROTECTION TO BEGIN 6" ABOVE FLOOR I. MAXIMUM SPACING FOR RESIDENTIAL PENDANT SPRINKLERS TO BE 14' X 14' UNLESS NOTED OTHERWISE IN HEAD LEGEND ON PLANS. J. MAXIMUM SPACING FOR STANDARD QR PENDANTS 130 SQ. FT. K. NO SPRINKLERS IN CLOSETS 24 SQ. FT. OR LESS L. NO SPRINKLERS IN BATHROOMS 55 SQ. FT. OR LESS M. SPRINKLER HEADS NEED TO BE AT LEAST 36 IN. AWAY FROM THE CENTER OF THE CEILING FANS. N. ALL ATTIC ACCESS TO BE PROTECTED WITH AN UPRIGHT SPRINKLER. 0. THE TWO MOST HYDRAULICALLY DEMANDING HEADS ARE LOCATED IN THE CROSSHATCHED AREA. P. THE FIRE SPRINKLER SYSTEM RISER SHALL HAVE A WARNING SIGN THAT SAYS "THE WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND PRESSURES TO FIGHT A FIRE. DEVICES THAT RESTRICT THE FLOW OF DECREASE THE PRESSURE OR AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM, SUCH AS WATER SOFTENERS, FILTRATION SYSTEMS, AND AUTOMATIC SHUTOFF VALVES, SHALL NOT BE ADDED TO THIS SYSTEM WITHOUT A REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST. DO NOT REMOVE THIS SIGN." ROOFITG 01ERISIb BLDG PAPER OVER 716" CD.X. oR OAR.' ES PER:PLAN 60 CFM FANKT.O. 4" PLYWOOD OVER .11141VLIF JOISTS 7.3"x30" ATTIC ACCESS ; . . . , 1 if ! i 1 I . .i 1 I --7-----r—, 1 Il• i r -,f 1 ! . 11 11 4 , .... I, ji 1! ii . • • . -..-., 1 if li T.&G. PLYWOOD OVER 2x10 F.J. re: R-30 INS044TION . h OPTIONAL HANDRAIL @ +36" AMR 5 55. 5,• Pwreetig, 4&/ed ad plovitz, SHEET NUMBER FP -1.0