Loading...
HomeMy WebLinkAboutPP - 4708 SOUTHCENTER BLVD BLDG H - THE BOULEVARD AT SOUTH STATION - PERMITS AND PLANS4708 SOUTHCENTER BLVD BLDG H ASSOCIATED PERMITS OS -5-185 A B C H J 1 2 3 4 5 7 8 9 10 FIRE ALARM WIRE LEGEND DESIG. DESCRIPTION A 16/2 FPLR INITIATING CIRCUIT WIRING B 14/2 FPLR INDICATING CIRCUIT WIRING C 18/4 FPLR ANNUNCIATOR CIRCUIT WIRING D 14/2 FPLP DUCT DETECTOR OR DOOR HOLDER POWER WIRING E AWG-16-THHW FOR DIRECT BURY/WET LOCATION KEY LEGEND AND COMPONENT LIST SYMBOL DESCRIPTION QTY PART # MANUFACTOR MOUNTING SPEC FIRE ALARM CONTROL PANEL 1 FX -350 -DDR MIRCOM WALL TOP @ 66' I FACP i FIRE SIGNAL EXPANDER pa WALL TOP @ 66' 1 FSE I A 1.37 (4X maximum m ft.) m IL) F,,124 Finished floor ANNUNCIATOR WALL TOP @ 66' I ANN I TRANSMITTER FIELD VERIFY I TRAN I SUBSCRIBER TERMINAL UNIT FIELD VERIFY I sTu I HORN WALL @ 80'-96' OCI MINI -HORN 36 MH -25W MIRCOM WALL @ 80'-96' BELL 1 MB -G10 -24R WHEELOCK OUTSIDE WALL @ 10' STROBE WALL @ 80'-96' )j WEATHER PROOF STROBE 1 RSSWP-2475-FR WHEELOCK WALL @ 80'-96' WP k( ND HORN -STROBE WALL @ 80'-96' 0 CEILING MOUNTED HORN/STROBE CEILING 0 CEILING MOUNTED STROBE CEILING CHIME FIELD VERIFY C 0 SPEAKER WALL @ 90' Q JUNCTION BOX FIELD VERIFY DOOR HOLDER FIELD VERIFY m DOOR STRIKE FIELD VERIFY CM F MANUAL PULL STATION WALL @ 48' eta SMOKE DETECTOR ABOVE CEILING ABOVE CEILING OR IN DUCT 0 SMOKE DETECTOR CEILING - 3' FROM AIR DEFUSER 0 BL SMOKE DETECTOR BELOW FLOOR BELOW FLOOR ® 194° FIXED TEMP HEAT DETECTOR 6 MIX -3300 MIRCOM CEILING (DR 194° RATE OF RISE HEAT DETECTOR CEILING ®R 135° RATE OF RISE HEAT DETECTOR 12 MIX -3300 MIRCOM CEILING 194°D 194° FIXED TEMP HEAT DETECTOR CEILING LINE TYPE HEAT DETECTOR FIELD VERIFY WF WATERFLOW SWITCH RISER PIPE Ps PRESSURE SWITCH RISER PIPE TS TAMPER SWITCH GATE VALVE JB JUNCTION BOX ALONGSIDE DEVICE FIELD VERIFY M MONITOR MODULE FIELD VERIFY R ADDRESSABLE RELAY FIELD VERIFY General Note' LAPPA 92-2002 Fdition 1 -5ec. 5.6.5,1..heat-xn irq fire deledor' ehall be located on the \ ceiling not lex than IO0nn (4 in) from the nidewall or on the oidewall/ between lOOnn and 300rrrr (4in and /Zin) from the ceiling, See figure F.5.6.5.1 2 -5ec. 5,732,1,,. sr oke deledorn'hall be located on the ceiling not / .• \ le" than lOOnn (4 in) from a eidewal/ to the near edge or, if on a eidewoll, bdween lOOmm and 500mm (4in and /2/n) down from the ceiling to the lop of the detector.See figure F.5.9321 3 -5ec. /i.5.1.4,1 Detector"hould not be located in a direct airflow or / ■, cloner than In (3 ft.) from an air eupply diffuuer or return air opening. Supply or return eource' larger than thone cortrtorny found in residential and entail commercial eetablidtnerin can require greater clearance to'rtoke defectors 5irtilady, entoke detectornnhould be located farther away from high velocity air eupplien. I/1\4 -5ec. 5./2.4 The operable part of each (larval fire alarm box dtat/ be / • l not ten than I./ro (5%2 fI) and not more than /37rt (4 Yz ft.) above floor level. See figure F.5./2.4 /i\5 -5ec. 9.5.4 Wall mounted appliances d ial1 be monied xx-h that the / ■ \ entire ten' in not le" than 2n (80 in) and not greater than 2.4m (96 in) above the finished floor. See figure F.95.4 pi -cc. 4.4.1.4.1 Dedicated branch circuit. A dedicated Morph circuit of one of the following ehall'upply primly power: (1)Commercial light and power. (2) An engine -driven generator or equivalent in accordarce with 4,4.1.92, where a pereon specifically (rained in if' operation in on duty at all time'. (5) An engine -driven generator or equivalent arranged for cogeneration with comp ercid light and power in accordance with 4.4.1.92, where a person specifically trained in if' operation in on duty al dl trip jee K M N Ceiling 100 mm (4 In.) Acceptabe hem Note: Measurements shown am to the closest edge of the detector. 1,0 mm (4 in.) m'nimum Never here Top of detector acceptable here 300 mm (12 in.) maximum Sidewall N MAP OF LOCATION lk FX-350-60DR outside g 0 220 0 380 0.005: 0.007;: 0000:::' 0000 0 000 10.000. <. 0 000 0 000 Notification Appl Circuit Notification Appl Circuit Notification Appl Circuit 1 # of NAC's Used Tit, 0000 0.000 0.000 0.168 0000 0.000 #14 Solid #14 Solid 18 Solid #14 Solid 450 200 Command Shortcuts Configure Circuits Print Page Project Inftrmation Project Name: PARK PLACE BY THE WOODS Prepared By: NELS Project ID: 87474 Date: 5/8/2008 Notiricaton Appl Circuit 18 MH -25W Unused Unused Unused Totals Notfiicatim Apel Circuit 4 18 MH -25W Unused Unused Unused Totals 0 000 Q:486 1 MB -G10 & RSSP Unused Unused Unused Q Totals awe 0 ii lthout Comrnerft As Noted In Red Per The Attached Letter i nese plans have been revived by The e Tut^.iita Fire Prevention Bureau for cerlformanee with current city standards. Acceptance i t,:ubiect to errors and omissions which do nut authorize violations of adopted staneares and C4.11113i1 ..s. 1 rtr r� nonsit Uy for adequacy r d the d sicner. Additions, ciei slid' : Of drawings atter this date u'li void iiY:-�._)tinCe ;^�require will a resubmittal of r ,:isod drE •ings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire. Prevention Bureau. Date: ! i 3/03 By: 9 NOTICE A completed, signed, Tukwiia Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. -1ns.l-etj1 ►n4tva1 p.1( fk4PvLs 4+co►»so' e,r,i-s a3- 0nal;c4-kJ TUKWiLA FIRE DEPARTMEN$ Please call: 575-440Z and give this job ?4o. 03 -S- /gJ and exact address for shuts down or restoration approval; I L :. ':' 2008 Tukwila Fire 7. P z 0 rn ISSUED FOR APPROVAL d z 0 C) Z w z 0 ELECT. FIREOI*099KW 206-575-0311 107 WASHINGTON BLVD. ALGONA WA, 98001 PARK PLACE BY THE WOODS BLDG. H 4708 SOUTH CENTER BLVD. TUKWILA WA, 98188 RISER/BOM - FIRE ALARM PLAN APPROVED APPROVED BY : ER DRAWN BY: RG DATE: 5-6-08 JOB# 87474 DWG. NO.: FA -01 1416-JOperable �IIII pa 1.1 (314 minimum A 1.37 (4X maximum m ft.) m IL) F,,124 Finished floor 4S—Sidewall N MAP OF LOCATION lk FX-350-60DR outside g 0 220 0 380 0.005: 0.007;: 0000:::' 0000 0 000 10.000. <. 0 000 0 000 Notification Appl Circuit Notification Appl Circuit Notification Appl Circuit 1 # of NAC's Used Tit, 0000 0.000 0.000 0.168 0000 0.000 #14 Solid #14 Solid 18 Solid #14 Solid 450 200 Command Shortcuts Configure Circuits Print Page Project Inftrmation Project Name: PARK PLACE BY THE WOODS Prepared By: NELS Project ID: 87474 Date: 5/8/2008 Notiricaton Appl Circuit 18 MH -25W Unused Unused Unused Totals Notfiicatim Apel Circuit 4 18 MH -25W Unused Unused Unused Totals 0 000 Q:486 1 MB -G10 & RSSP Unused Unused Unused Q Totals awe 0 ii lthout Comrnerft As Noted In Red Per The Attached Letter i nese plans have been revived by The e Tut^.iita Fire Prevention Bureau for cerlformanee with current city standards. Acceptance i t,:ubiect to errors and omissions which do nut authorize violations of adopted staneares and C4.11113i1 ..s. 1 rtr r� nonsit Uy for adequacy r d the d sicner. Additions, ciei slid' : Of drawings atter this date u'li void iiY:-�._)tinCe ;^�require will a resubmittal of r ,:isod drE •ings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire. Prevention Bureau. Date: ! i 3/03 By: 9 NOTICE A completed, signed, Tukwiia Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. -1ns.l-etj1 ►n4tva1 p.1( fk4PvLs 4+co►»so' e,r,i-s a3- 0nal;c4-kJ TUKWiLA FIRE DEPARTMEN$ Please call: 575-440Z and give this job ?4o. 03 -S- /gJ and exact address for shuts down or restoration approval; I L :. ':' 2008 Tukwila Fire 7. P z 0 rn ISSUED FOR APPROVAL d z 0 C) Z w z 0 ELECT. FIREOI*099KW 206-575-0311 107 WASHINGTON BLVD. ALGONA WA, 98001 PARK PLACE BY THE WOODS BLDG. H 4708 SOUTH CENTER BLVD. TUKWILA WA, 98188 RISER/BOM - FIRE ALARM PLAN APPROVED APPROVED BY : ER DRAWN BY: RG DATE: 5-6-08 JOB# 87474 DWG. NO.: FA -01 A 1 2 3 4 5 6 7 8 9 10 B C D 75cd TO NAC CKT. #3 E 1050 SQFT 2 BEDROOM 1.25 BATH DINING 00 00 KITCHEN -FROM 2ND FL A,B LIVING ROOM BATH ROOM O TO ATTIC BEDROOM STORAGE 101 F 1050 SIFT 2 BEDROOM 1.25 BATH LIVING ROOM STORAGE W/DHOOKUP CLOSET EOL BEDROOM DN 102 UP DINING 0 00 KITCHEN W/D HOOK UP FD G H 1050 SOFT 2 BEDROOM 1.25 BATH DINING LIVING ROOM 00 00 KITCHEN 9�O FROM 2ND FL STORAGE BEDROOM BEDROOM 1050 SIFT 2 BEDROOM 1.25 BATH LIVING ROOM - DINING STORAGE 12332 : DN •T ATTIC 2B,A _ft FROM 2ND FL A,B 2 G0 00 KITCHEN 106 UP W / D HOCK UP CLOSET TO ATTIC BATH ROOM 1ST FLOOR - BLDG. H 1/8"_1 '-0" J 1050 SIFT 2 BEDROOM 1.25 BATH DINING Go KITCHEN J u 0I / B BATH ROOM O FROM 2ND FL A,B 0 LIVING ROOM TO ATTIC STORAGE 109 K 1050 SQFT 2 BEDROOM 1.25 BATH LIVING ROOM DINING STORAGE W/D HOOK LIP CLOSET BEDROOM TO ATTIC BEDROOM UP 110 FROM 2ND FL A, 00 00 KITCHEN CLOSET 9 L M FLAG NOTES: INSTALL SINGLE GANG JUNCTION BOX FOR FUTURE ADA TENANT. N GENERAL NOTES: 1. HEAT DETECTORS IN UNITS SHALL BE 135° RATE OF RISE. 2. HEAT DETECTORS IN THE ATTIC SPACE SHALL BE 194° FIXED TEMPERATURE. 3. DEDICATED FIRE ALARM SYSTEM CIRCUIT SHALL BE EQUIPPED WITH LOCKOUT DEVICES. 4. CONTROL PANEL RESET CODE SHALL BE 1-2-3-4-5 5. INSTALL THE FIRE ALARM CONTROL PANEL IN A U.L. LISTED HOFFMAN HEATED INCLOSURE (NEMA3 RATED). z 0 U) ISSUED FOR APPROVAL 0 z 0 0 Z W Z 0 W LL ELECT. FIREOI*099KW 206-575-0311 107 WASHINGTON BLVD. ALGONA WA, 98001 PARK PLACE BY THE WOODS BLDG. H d CO om�. CO / LL Ili 03 I- O) z g VJ c F- 0 1ST FLOOR - FIRE ALARM PLAN APPROVED BY: ER DRAWN BY: RG DATE: 5-6-08 JOB# 87474 DWG. NO.: FA -02 1 2 3 4 5 6' 7 8 9 10 1050 SQFT 2 BEDROOM 1.25 BATH DINING 0p 00 KITCHEN 0 - FROM ATTIC A,B 0 LIVING ROOM BATH ROOM O FROM ATTIC TO 2ND FLOOR STORAGE 103 W/D HOOK UP CLOSET BEDROOM TO 2ND FLOOR BEDROOM 1050 SOFT 2 BEDROOM 1.25 BATH LMNG ROOM STORAGE ON DINING o 00 KITCHEN WI D HOOK UP CLOSET TO 2ND FLOOR TO 2ND FLOOR DINING 1050 SOFT 2 BEDROOM 1.25 BATH 00 00 KITCHEN 0 B LMNG ROOM BATH ROOM O FROM ATTIC TO 2ND FLOOR STORAGE LIVING ROOM 1050 SOFT 2 BEDROOM 1.25 BATH STORAGE 107 W / D HOOKUP CLOSET BEDROOM TO 2ND FLOOR DN $ :/ 108 DINING 00 FROM ATTIC A,B 1 TO 2ND FLOOR W/D HOOK UP CLOSET KITCHEN 0 B \ BATH Roots N 2ND FLOOR - BLDG. H 1/8"=11-0" 1050 SQFT 2 BEDROOM 1.25 BATH DINING op O KITCHEN FROM ATTIC 0 B FROM ATTIC A,B 0 LIVING ROOM STORAGE BATH ROOM TO 2ND FLOOR W/D HOOK UP CLOSET BEDROOM TO 2ND FLOOR BEDROOM 1050 SQFT 2 BEDROOM 1.25 BATH LMNG ROOM STORAGE 112 FROM ATTIC A,B 7 DINING p0 00 KITCHEN TO 2ND FLOOR TO 2ND FLOOR BEDROOM GENERAL NOTES: 1. HEAT DETECTORS IN UNITS SHALL BE 135° RATE OF RISE. 2. HEAT DETECTORS IN THE ATTIC SPACE SHALL BE 194° FIXED TEMPERATURE. 3. DEDICATED FIRE ALARM SYSTEM CIRCUIT SHALL BE EQUIPPED WITH LOCKOUT DEVICES. 4. CONTROL PANEL RESET CODE SHALL BE 1-2-3-4-5 5. INSTALL THE FIRE ALARM CONTROL PANEL IN A U.L. LISTED HOFFMAN HEATED INCLOSURE (NEMA 3 RATED). N ( z 0 rn ISSUED FOR APPROVAL 0 z 0 U Z W 0Z NW ELECT. FIREOI*099KW 206-575-0311 107 WASHINGTON BLVD. ALGONA WA, 98001 PARK PLACE BY THE WOODS BLDG. H 4708 SOUTH CENTER BLVD. ILA WA, 98188 G c W U— 2ND FLOOR - FIRE ALARM APPROVED BY: ER DRAWN BY: RG DATE: 5-6-08 JOB# 87474 DWG. NO.: FA -03 1 2 3 4 5 6_ 7 8 9 10 A,B 0101:0001 A,B d FROM CONTROL PANEL 2B,A J 0 A,B A,B—ty AB 01:010 A� b 4 N A,B 6 01.0,15 Ab 01:0116 Ai IH ATTIC - BLDG. H 1 /8" _ 1 I -oil 0 A,B-52 A,B CIRCUIT DISCRIPTIONS: CKT.#1 - ROOM NOTIFICATION WEST. CKT.#2 - ROOM NOTIFICATION EAST. CKT.#3 - OUTDOOR BELL & STROBE N GENERAL NOTES: 1. HEAT DETECTORS IN UNITS SHALL BE 135° RATE OF RISE. 2. HEAT DETECTORS IN THE ATTIC SPACE SHALL BE 194° FIXED TEMPERATURE. 3. DEDICATED FIRE ALARM SYSTEM CIRCUIT SHALL BE EQUIPPED WITH LOCKOUT DEVICES. 4. CONTROL PANEL RESET CODE SHALL BE 1-2-3-4-5 5. INSTALL THE FIRE ALARM CONTROL PANEL IN A U.L LISTED HOFFMAN HEATED INCLOSURE (NEMA3 RATED). ( z 0 Co ISSUED FOR APPROVAL ci z 0 C) Z w z 0 W LL ELECT. FIREOI*099KW 206-575-0311 107 WASHINGTON BLVD. ALGONA WA, 98001 PARK PLACE BY THE WOODS BLDG. H 4708 SOUTH CENTER BLVD. TUKWILA WA, 98188 CC w CC LL ATTIC - FIRE ALARM PLAN APPROVED BY : ER DRAWN BY: RG DATE: 5-6-08 JOB# 87474 DWG. NO.: FA -04 A B C 0 H J K 1 2 #14/2 #16/2 & #14/4 #16/2 & #14/4 3 ATTIC 01:007 01:006 #16/2 & #14/4 #16/2 & #14/4 #16/2 & #14/4 #16/2 & #14/4 01:001 #16/2 & #14/4 #16/2 #16/2 dT -TAP b 01:010 #16/2 & #14/4 #16/2 & #14/4 #16/2 & #14/4 #16/2 & #14/4 #16/2 & #14/4 L M N #16/2 & #14/4 #14/2 b ® b ®) ®b ® 01:015 01:016 4 2ND FLOOR m#14/2 1:7-#16/2 & #14/4 01:008 .027ma .027ma .027ma UNIT 103 -#16/2 & #14/4 c -#16/2 & #14/4 vv -#16/2 & #14/4 -#16/2 & #14/4 .027ma .027ma 01:004 .027ma UNIT 104 -#14/2 -#16/2 & #14/4 .027ma .027ma 01:002 .027ma UNIT 107 0-#16/2 & #14/4 c7-#16/2 & #14/4 Q-#16/2 & #14/4 -#16/2 & #14/4 5 r EOL .027ma .027ma 01:009 .027ma L_ UNIT 101 6` EOL 1ST FLOOR #18/2 75cd 1 #16/2 & #14/4 - #16/2 & #14/4 - #16/2 & #14/4 - #16/2 & #14/4 #16/2 & #14/4 b o ATTIC 01:011 .027ma UNIT 108 .027ma .027ma 01:013 .027ma UNIT 111 #16/2 & #14/4 -V #16/2 & #14/4 -1z, #16/2 & #14/4 -0 #16/2 & #14/4 #16/2 & #14/4 -v #14/2 .027ma .027ma 01:017 .027ma " .027ma UNIT 112 .027ma #16/2 & #14/4 -1z, #14/2 -0 2ND FLOOR .027ma .027ma 01:005 .027ma UNIT 102 01:003 .027ma .027ma " .027ma UNIT 105 #18/2 .040ma .138ma WEST 7 8 9 10 TO CENTRAL]PHONE LINE #1 STATION FACP MIRCOM FX-350-60DDR PHONE LINE #2 -, 120 VAC S (DEDICATED CKT.) DUAL LIE DIALER SLC NAC -1 #16/2 NAC -2 NAC -3 #14/4 NAC -4 #18/2 BATrEHY 12V-7AM BAT(ER! 12V•7AH RISER DIAGRAM SPARE r -r 01:012 • .027ma .027ma .027ma UNIT 106 01:014 .027ma UNIT 109 .027ma .027ma 01:018 .027ma R UNIT 110 EOL .027ma .027ma 1ST FLOOR EAST CIRCUIT DISCRIPTIONS: CKT.#1 - ROOM NOTIFICATION WEST. CKT.#2 - ROOM NOTIFICATION EAST. CKT.#3 - OUTDOOR BELL & STROBE GENERAL NOTES: 1. HEAT DETECTORS IN UNITS SHALL BE 135° RATE OF RISE. 2. HEAT DETECTORS IN THE ATTIC SPACE SHALL BE 194° FIXED TEMPERATURE. 3. DEDICATED FIRE ALARM SYSTEM CIRCUIT SHALL BE EQUIPPED WITH LOCKOUT DEVICES. 4. CONTROL PANEL RESET CODE SHALL BE 1-2-3-4-5 5. INSTALL THE FIRE ALARM CONTROL PANEL IN A U.L LISTED HOFFMAN HEATED INCLOSURE (NEMA3 RATED). ( z 0 Co ISSUED FOR APPROVAL 0 z 0 C) z w z 0 ct ELECT. FIREOI*099KW 206-575-0311 107 WASHINGTON BLVD. ALGONA WA, 98001 PARK PLACE BY THE WOODS BLDG. H 4708 SOUTH CENTER BLVD. TUKWILA WA, 98188 APPROVED BY : ER DRAWN BY: RG DATE: 5-6-08 JOB# 87474 DWG. NO.: FA -05 1