HomeMy WebLinkAboutPP - 4708 SOUTHCENTER BLVD BLDG J - THE BOULEVARD AT SOUTH STATION - PERMITS AND PLANS4708 SOUTHCENTER BLVD BLDG J ASSOCIATED PERMITS 08-F-183 1 2 3 4 5 6 7 8 9 10 N FIRE ALARM WIRE LEGEND DESIG. DESCRIPTION A 16/2 FPLR INITIATING CIRCUIT WIRING B 14/2 FPLR INDICATING CIRCUIT WIRING C 18/4 FPLR ANNUNCIATOR CIRCUIT WIRING D 14/2 FPLP DUCT DETECTOR OR DOOR HOLDER POWER WIRING E AWG-18-THHW FOR DIRECT BURY/WET LOCATION KEY LEGEND AND COMPONENT LIST SYMBOL DESCRIPTION QTY PART # MANUFACTOR MOUNTING SPEC FIRE ALARM CONTROL PANEL 1 FX -350 -DDR MIRCOM WALL TOP @ 66' I FACP I FIRE SIGNAL EXPANDER Mr WALL TOP @ 66' ( FSE I ANNUNCIATOR 1. (3)4 min 1.37 (4)4 maximum m ft.) mum v WALL TOP @ 66' I ANN J TRANSMITTER FIELD VERIFY i TRAN I SUBSCRIBER TERMINAL UNIT FIELD VERIFY I sTu ( HORN WALL @ 80'-96' MINI -HORN 36 MH -25W MIRCOM WALL @ 80'-96' CEI BELL 1 MB -G10 -24R WHEELOCK OUTSIDE WALL @ 10' )2( STROBE WALL @ 80'-96' WP ):( WEATHER PROOF STROBE 1 RSSWP-2475-FR WHEELOCK WALL @ 80'-96' >El HORN -STROBE WALL @ 80'-96' 01 CEILING MOUNTED HORN/STROBE CEILING 0 CEILING MOUNTED STROBE CEILING C CHIME FIELD VERIFY 0 SPEAKER WALL @ 90' JO JUNCTION BOX FIELD VERIFY DOOR HOLDER FIELD VERIFY LIM DOOR STRIKE FIELD VERIFY Ca F MANUAL PULL STATION WALL @ 48' ® AB SMOKE DETECTOR ABOVE CEILING ABOVE CEILING OR IN DUCT ® SMOKE DETECTOR CEILING - 3' FROM AIR DEFUSER ® BL SMOKE DETECTOR BELOW FLOOR BELOW FLOOR ® 194° FIXED TEMP HEAT DETECTOR 6 MIX -3300 MIRCOM CEILING (DR 194° RATE OF RISE HEAT DETECTOR CEILING (DR 135° RATE OF RISE HEAT DETECTOR 12 MIX -3300 MIRCOM CEILING 19406D 194° FIXED TEMP HEAT DETECTOR CEILING C01—> LINE TYPE HEAT DETECTOR FIELD VERIFY WF WATERFLOW SWITCH RISER PIPE PS PRESSURE SWITCH RISER PIPE Ts TAMPER SWITCH GATE VALVE JB JUNCTION BOX ALONGSIDE DEVICE FIELD VERIFY M MONITOR MODULE FIELD VERIFY R ADDRESSABLE RELAY FIELD VERIFY General Nofe, NP,PA 72-2002 Edition t 1 -sec. 5,63,1„.heal--ening fire detectors chat/ be located on the • ceiling not le55 than lOOnn (4 in) Iron the sidewall or on the 5idewall5 between lOOnn and 300m (4in and 12in.) from the ceiling. See figure 1".5,63.1 A2 -Sec. 5.732,1°.,,smoke defedor5 Shall be located on the ceiling not ■ le55 Phan /OOmn (4 in) from a 5idewall to the near edge Of, if on a e'idewall, between/00m and 300m (4in and 12in) down from the ceiling to the fop of the defector. See figure 1-.5.732.1 n 3 sec, /5,7.4,1 Detedor5 Should not be located in a direct airflow or • \ do5er than In (3 ft.) tion an air Supply diffuser or return air opening,, Supply or return 5ouree5 larger than those conrioniy found in re5idenfial and Small commercial e5tabliehr ent5 con require greater clearance to Smoke de/cc-torn 5inilarly, 5noke detector, Should be located farther away from high velocity air Supplies. r,4 -Sec. 5.12.4 The operable part of each nanual fire slain box Shat! be • \ not less than 1.1n (54 ft.) and not none than 137m C4 %Z ft.) above floor level. See figure F.5.12.4 5 -Sec. 7.5.4 Wall mounted appliances Shall be mounted/ that the entire lens i5 not 1e55 than 2n (80 in) and not greater than 2.4n(96 in) above the finished floor, See figure F.75.4 6 -sec. 4.4.1.4.1 Dedicated branch circuit. A dedicated branch circuit of • one of the following Shall supply prinary power: (I) Gonmercial light and power. (2) An engine -driven generator or equivalent in accordance with 4.4.1.92, where a person Specifically trained in it, operation i5 on duly at all tires (3) An engine -driven generator or equivalent arrarrjed for cogeneration with corrercial light and power in accordance with 4.4.1.92, where a person specifically trained in its operation is on duty of all fire,. ir. Ceiling 100 mm (4 in.) Acceptable here Note: Measurements shovel are to the closest edge of the detector. mm (4 in.) mimum Never here Top of detect acceptable here x,5,732,1 300 mm (12 in.) maximum Sidewall Sidewall 2.4 m (96 in.) maximum 2m (80 in.) minimum • Leis Finished flow N MAP OF LOCATION Isk FX-350-6ODR outside FX -350 CTRL Panel Addrsbl SLC Devices RAM-300LCDR Other Other Notification Appl Circuit Notification Appl Circuit Notification A. pl Circuit Notification Appl Circuit 1 # of NAC's Used 0.220 0.380 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000>< 0.000 0.000 0,000. 0.000 0.000 0.000 0.000 0,000 0.000 0.000 0.000 0-000 0.488: 0.000; 0.486 0.000 0.168.;: 0.000< 0.000: 0.000- 0.000:: #14 Solid #14 Solid #18 Solid 450 450 200 & 40°l0 #14 Solid ti�rrer� fin t$1i::i 3tt4f.' .til Ci9j it�I 3Yff'-5�: Command Shortcuts Configure Circuits 0 Print Page Project Initrmation Project Name: PARK PLACE BY THE WOODS Prepared By: NELS Project ID: 87474 Date: 5/812008 Notificaton Appl Circuit 18 MH -25W Unused Unused Unused 18 MH -25W Unused Unused Unused Totals 0.000 0:4801 <' Notificaticn Appl Circuit BNB: Totals 0000:' ,0A86-0. ai Notification App? Crcut......................: 1 MB -010 & RSSP Unused Unused Unused Totals 0.000:: 0.168 7 a c [j Without Comments E As Noted In Red • Per The Attached Letter I nese plans have been revia•xid by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is u;; i&ct to errors and - omissions which do not thc i7 - violations of adopted stanooras and o-,, man, e responsibility for the adequacy of d, :i ll r s( tt tatty ;tri the designer. Additions, U"i 6oi IS Of 5-3viStOfis to these drawings atter this date will void thI-s.acceptance and Will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. ci Date: s-57-1 3- By: TUKWILA FIRE DEPARTMEN Please call: 575.4401, and give this job No. OS- Fri and exact address for shut; down or restoration approvah —27,1s -k1( r' 5444ipo►,3 ci. s 7`t otic.+t,;J 1 NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing, rl:41111 Vi°8 cgk//k9 eG',// � J t:.. 1 . 2000 Tukwila Fire z O ISSUED FOR APPROVAL d z 0 ci z 206-575-0311 107 WASHINGTON BLVD. ALGONA WA, 98001 PARK PLACE BY THE WOODS BLDG. J ILA WA, 98188 I— cc W cc LL RISER/BOM - FIRE ALARM PLAN APPROVED BY : ER DRAWN BY: RG DATE: 5-6-08 JOB# 87474 DWG. NO.: FA -01 ami to overabte Mr 1. (3)4 min 1.37 (4)4 maximum m ft.) mum v m f.) f124 Finished floor 4—Sidewall ////////////// Sidewall 2.4 m (96 in.) maximum 2m (80 in.) minimum • Leis Finished flow N MAP OF LOCATION Isk FX-350-6ODR outside FX -350 CTRL Panel Addrsbl SLC Devices RAM-300LCDR Other Other Notification Appl Circuit Notification Appl Circuit Notification A. pl Circuit Notification Appl Circuit 1 # of NAC's Used 0.220 0.380 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000>< 0.000 0.000 0,000. 0.000 0.000 0.000 0.000 0,000 0.000 0.000 0.000 0-000 0.488: 0.000; 0.486 0.000 0.168.;: 0.000< 0.000: 0.000- 0.000:: #14 Solid #14 Solid #18 Solid 450 450 200 & 40°l0 #14 Solid ti�rrer� fin t$1i::i 3tt4f.' .til Ci9j it�I 3Yff'-5�: Command Shortcuts Configure Circuits 0 Print Page Project Initrmation Project Name: PARK PLACE BY THE WOODS Prepared By: NELS Project ID: 87474 Date: 5/812008 Notificaton Appl Circuit 18 MH -25W Unused Unused Unused 18 MH -25W Unused Unused Unused Totals 0.000 0:4801 <' Notificaticn Appl Circuit BNB: Totals 0000:' ,0A86-0. ai Notification App? Crcut......................: 1 MB -010 & RSSP Unused Unused Unused Totals 0.000:: 0.168 7 a c [j Without Comments E As Noted In Red • Per The Attached Letter I nese plans have been revia•xid by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is u;; i&ct to errors and - omissions which do not thc i7 - violations of adopted stanooras and o-,, man, e responsibility for the adequacy of d, :i ll r s( tt tatty ;tri the designer. Additions, U"i 6oi IS Of 5-3viStOfis to these drawings atter this date will void thI-s.acceptance and Will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. ci Date: s-57-1 3- By: TUKWILA FIRE DEPARTMEN Please call: 575.4401, and give this job No. OS- Fri and exact address for shut; down or restoration approvah —27,1s -k1( r' 5444ipo►,3 ci. s 7`t otic.+t,;J 1 NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing, rl:41111 Vi°8 cgk//k9 eG',// � J t:.. 1 . 2000 Tukwila Fire z O ISSUED FOR APPROVAL d z 0 ci z 206-575-0311 107 WASHINGTON BLVD. ALGONA WA, 98001 PARK PLACE BY THE WOODS BLDG. J ILA WA, 98188 I— cc W cc LL RISER/BOM - FIRE ALARM PLAN APPROVED BY : ER DRAWN BY: RG DATE: 5-6-08 JOB# 87474 DWG. NO.: FA -01 1 2 3 4 5 7 8 9 10 A B C 0 E DINING 1050 SQFT 2 BEDROOM 1.25 BATH 00 00 KITCHEN FROM 2ND FL A,B LIVING ROOM O 7 I � BEDROOM STORAGE F 1050 SOFT 2 BEDROOM 1.25 BATH LIVING ROOM DINING STORAGE 101 102 W/DHOOK UP CLOSET EOL BEDROOM ON UP FROM 2ND FL A,B J O 00 KITCHEN TO ATTIC W/D HOOK UP CLOSET 0 J BATH ROOM LI UI G I1 1050 SOFT 2 BEDROOM 1.25 BATH DINING LMNG ROOM 00 0o KITCHEN vi FROM 2ND FL A,B 0 STORAGE 1050 SQFT 2 BEDROOM 1.25 BATH LMNG ROLA DINING 1 105 W/D HOOK UP BEDROOM CLOSET TO ATTIC BEDROOM DN 2 STORAGE ,A 106 P T ATTIC W I 0 OOK UP FROM 2ND FL. A,B 2 00 00 KITCHEN CL.CSET 0 BATH ROOM 1ST FLOOR - BLDG. J 1 /8"= 1-0" J 1050 SQFT 2 BEDROOM 1.25 BATH DINING LIVING ROOM 0 0 00 11 KITCHEN 0 0 BATH ROOM TO ATTIC STORAGE K 1050 SQFT 2 BEDROOM 1.25 BATH LMNG ROOM DINING STORAGE 109 110 W/ D HOOK UP CLOSET BEDROOM TO ATTIC BEDROOM 75cd EOL DN P FROM 2ND FL. A,B �8 O 0 0 KITCHEN W/D HOOK UP CLOSET EOL BEDROOM 9 U L GENERAL NOTES: M N 1. HEAT DETECTORS IN UNITS SHALL BE 135° RATE OF RISE. 2. HEAT DETECTORS IN THE ATTIC SPACE SHALL BE 194° FIXED TEMPERATURE. 3. DEDICATED FIRE ALARM SYSTEM CIRCUIT SHALL BE EQUIPPED WITH LOCKOUT DEVICES. 4. CONTROL PANEL RESET CODE SHALL BE 1-2-3-45 5. INSTALL THE FIRE ALARM CONTROL PANEL IN A U.L. LISTED HOFFMAN HEATED INCLOSURE (NEMA3 RATED). Z 0 w z 0 LU II ELECT. FIREOI*099KW 206-575-0311 107 WASHINGTON BLVD. ALGONA WA, 98001 PARK PLACE BY THE WOODS BLDG. J 4708 SOUTH CENTER BLVD. TUKWILA WA, 98188 1ST FLOOR - FIRE ALARM PLAN APPROVED BY: ER DRAWN BY: RG DATE: 5-6-08 JOB# 87474 DWG. NO.: FA -02 9 2 3 5 7 8 9 10 L A B C 0 E F G H J K L M N 1050 SQFT 2 BEDROOM 1.25 BATH DINING LMNG ROOM 00 Oo KITCHEN STORAGE 1050 SQFT 2 BEDROOM 1.25 BATH WING ROOM DINING STORAGE 103 104 DIN TO 2ND FLOOR W/D HOOK UP CLOSET TO 2ND FLOOR r 100 FROM - ATTIC A,B KITCHEN W/D HOOK UP CLOSET FROM ATTIC TO 2ND FLOOR O BA U��-j ROOM BEDROOM TO 2ND FLOOR 0 1050 SQFT 2 BEDROOM 1.25 BATH DINING LIVING ROOM 00 Oo KITCHEN TO 2ND FLOOR STORAGE 1050 SQFT 2 BEDROOM 1.25 BATH WING ROOM DINING STORAGE 107 FROM ATTIC BEDROOM CLOSET TO 2ND FLOOR BEDROOM DN 108 O o0 W/D HOOKUP CLOSET FROM ATTIC TO 2ND FLOOR KITCHEN OI BATH ROOM 11 _ lo BEDROOM TO 2ND FLOOR BEDROOM 1050 SQFT 2 BEDROOM 1.25 BATH DINING LING ROOM 00 Co KITCHEN NI UI FROM ATTIC L ) O FROM ATTIC BATH ROOM O TO 2ND FLOOR STORAGE LIVING ROOM 1050 SQFT 2 BEDROOM 1.25 BATH STORAGE 111 112 DN W/ D HOOK UP CLOSET BEDROOM TO 2ND FLOOR 2ND FLOOR - BLDG. J 1/8"=-11-0" FROM ATTIC A,B 7 DINING Co o0 KITCHEN W/D HOOK UP CLOSET FROM ATTIC TO 2ND FLOOR O 0AT�1 ROOM BEDROOM U TO 2ND FLOOR BEDROOM GENERAL NOTES: 1. HEAT DETECTORS IN UNITS SHALL BE 135° RATE OF RISE. 2. HEAT DETECTORS IN THE ATTIC SPACE SHALL BE 194° FIXED TEMPERATURE. 3. DEDICATED FIRE ALARM SYSTEM CIRCUIT SHALL BE EQUIPPED WITH LOCKOUT DEVICES. 4. CONTROL PANEL RESET CODE SHALL BE 1-2-3-4-5 5. INSTALL THE FIRE ALARM CONTROL PANEL IN A U.L. USTED HOFFMAN HEATED INCLOSURE (NEMA 3 RATED). ( z 0 ISSUED FOR APPROVAL d z 0 G) Z w z 0 w L� ELECT. FIREOI*099KW 206-575-0311 107 WASHINGTON BLVD. ALGONA WA, 98001 PARK PLACE BY THE WOODS BLDG. J CC W CCU - CL is CC0 0 J LI- CI LCI CV APPROVED BY: ER DRAWN BY: RG DATE: 5-6-08 JOB# 87474 DWG. NO.: FA -03 5 6 8 10 A B C D E F G H J K N rfk'B 01.015 I I Cly A,B II n A'B 01:001 FROM CONTROL C A,B 2B,APANEL—p A,B A/ " 47 n A,B 01:006 A�B� ® d1 A,B 6 A,B- A,B I 1 I ATTIC - BLDG. J 1 /8" =1'-0" 01:010 A'B Fl tl II 0 A,B— A,B 0—A,B 01® AB1-1 CIRCUIT DESCRIPTIONS: CKT.#1 - ROOM NOTIFICATION WEST. CKT.#2 - ROOM NOTIFICATION EAST. CKT.#3 - OUTDOOR BELL & STROBE GENERAL NOTES: 1. HEAT DETECTORS IN UNITS SHALL BE 135° RATE OF RISE. i HEAT DETECTORS IN THE ATTIC SPACE SHALL BE 194° FIXED TEMPERATURE. 3. DEDICATED FIRE ALARM SYSTEM CIRCUIT SHALL BE EQUIPPED WITH LOCKOUT DEVICES. 4. CONTROL PANEL RESET CODE SHALL BE 1-2-3-4-5 5. INSTALL THE FIRE ALARM CONTROL PANEL IN A U.L LISTED HOFFMAN HEATED INCLOSURE (NEMA 3 RATED). z 0 ISSUED FOR APPROVAL ci z 0 w V Z LU z 0 rr ELECT. FIREOI*099KW 206-575-0311 107 WASHINGTON BLVD. ALGONA WA, 98001 PARK PLACE BY THE WOODS BLDG. J 4708 SOUTH CENTER BLVD. TUKWILA WA, 98188 - FIRE ALARM PLAN APPROVED BY : ER DRAWN BY: RG DATE: 5-6-08 JOB# 87474 DWG. NO.: FA -04 1 2 3 4 5 6 7 8 9 10 A G H J K L M N #14/2 ATTIC #16/2 & #14/4 01:007 #16/2 & #14/4 01:006 #16/2 & #14/4 #16/2 & #14/4 #16/2 & #14/4 #16/2 & #14/4 01:001 q (Di #16/2 #16/2 d T -TAP b #16/2 & #14/4 01:010 #16/2 & #14/4 #16/2 & #14/4 #16/2 & #14/4 #16/2 & #14/4 #16/2 & #14/4 #14/2 b® b0 #16/2 & 4/4 01:015 01:016 #16/2 & #14/4 ATTIC #14/2 v-#16/2 & #14/4 ic7- #16/2 & #14/4 #16/2 & #14/4 K:77 #16/2 & #14/4 t"-- #16/2 & #14/4 • 01:008 .027ma .027ma .027ma UNIT 103 .027ma .027ma 01:004 .027ma UNIT 104 • .027ma .027ma 01:002 .027ma UNIT 107 0-#14/2 0-#16/2 & #14/4 0-#16/2 & #14/4 K:7- #16/2 & #14/4 vu- #16/2 & #14/4 o- #16/2 & #14/4 2ND FLOOR #14/4 #16/2 #14/4 #16/2 & #14/4 --z7 #16/2 & #14/4 -0 #16/2 & #14/4 --K7 #16/2 & #14/4 01:011 .027ma .027ma .027ma 01:013 .027ma UNIT 108 UNIT 111 #16/2 & #14/4 #16/2 & #14/4 -0 #16/2 & #14/4 -z7 #16/2 & #14/4 #16/2 & #14/4 #14/2 -1z7 .027ma .027ma 01:017 .027ma .027ma .027ma UNIT 112 L #16/2 & #14/4 -z7 #14/2 2ND FLOOR EOL .027ma EOL 1ST FLOOR .027ma #18/2 d 75cd 01:009 .027ma UNIT 101 .027ma .027ma 01:005 .027ma UNIT 102 01:003 .027ma .027ma .027ma UNIT 105 #18/2 .040ma .138ma 01:012 .027ma .027ma UNIT 106 .027ma 01:014 .027ma UNIT 109 .027ma • .027ma 01:018 EOL -.027ma .027ma .027ma UNIT 110 1ST FLOOR WEST FACP TO CENTRAL F- PHONE LINE #1 ---t STATION _ PHONE LINE #2 -% 120 VAC s (DEDICATED CKT.) 5 rim ...: • . •,„:. MIRCOM FX-350-60DDR DUAL 1.11€ DIALER SLC NAC -1 #16/2 NAC -2 #14/4 NKC-7- p NAC -4 #18/2 BATTERY BATTERY I 12V -7P11 12V -7A1 RISER DIAGRAM SPARE EAST CIRCUIT DESCRIPTIONS: CKT.#1 - ROOM NOTIFICATION WEST. CKT.#2 - ROOM NOTIFICATION EAST. CKT.#3 - OUTDOOR BELL & STROBE GENERAL NOTES: 1. HEAT DETECTORS IN UNITS SHALL BE 135° RATE OF RISE. 2. HEAT DETECTORS IN THE ATTIC SPACE SHALL BE 194° FIXED TEMPERATURE. 3. DEDICATED FIRE ALARM SYSTEM CIRCUIT SHALL BE EQUIPPED WITH LOCKOUT DEVICES. 4. CONTROL PANEL RESET CODE SHALL BE 1-2-3-4-5 5. INSTALL THE FIRE ALARM CONTROL PANEL IN A U.L USTED HOFFMAN HEATED INCLOSURE (NEMA 3 RATED). z 0 ISSUED FOR APPROVAL ci z 0 LU 0 LU fit TE ELECT. FIREOI*099KW 206-575-0311 107 WASHINGTON BLVD. ALGONA WA, 98001 PARK PLACE BY THE WOODS BLDG. J 4708 SOUTH CENTER BLVD. TUKVVILA WA, 98188 CC LLI CC LL BUILDING RISER DIAGRAM APPROVED BY: ER DRAWN BY: RG DATE: 5-6-08 JOB# 87474 DWG. NO.: FA -05 }