HomeMy WebLinkAboutPP - 14237 INTERURBAN AVE S - HARTMAN ESCROW - PERMITS AND PLANS14237 INTERURBAN AVE S ASSOCIATED PERMITS 02-F-174 two IFire & Security Battery Calculation Worksheet (all currents stated in mA) 08/07/02 PROJECT: Hartman Escrow Company, Tukwila, WA System Devices Device Description Quantity of Devices Standby mA Per Device Alarm mA Per Device Total Device Standby mA Total Device Alarm mA System Devices Standby Hrs. Required Unimode 200 Fire Alarm Control Unit 1 80 168 80 168 ADT-UDACT Unimode Digital Alarm Communicator 1 40 75 40 75 DIM -485 Unimode 200 Interface Module 1 0.2 0.2 0.2 0.2 ADT -LCD -40 Annunciator 1 54 54 54 54 MMF-301 Addressable Mini Monitor Module 9 2 2 18 18 MDL Synch- Circuit Module 1 11 35 11 35 Total System Current 203.2 350.2 Smoke Detectors I Auxiliary Devices SD300 Photoelectric Smoke Detector 9 3 7 27 63 ADT-BG-IOLX Addressable Manual Pull Station 3 2 2 6 6 HD -601 Heat Detector 135° Fixed Temp & Rate of Rise 3 2 2 6 6 HD -601 Heat Detector 194° Fixed Temp & Rate of Rise 6 2 2 12 12 Device Totals 35 51 87 Notification Appliances (list all) Standby Hrs. Required P24110 Horn/Strobe 110 Candela 7 N/A 209 N/A 1463 S241575 Strobe 15/75 Candela 2 N/A 93 N/A 186 S24110K Strobe 110 Candela Weatherproof 1 N/A 191 N/A 191 B3210-022 10" Bell 1 N/A 30 N/A 30 • 20.08 0 Notification Appliance Totals 11 N/A 1870 Summary Section Standby Hrs. Required 60 Alarm Sounding Minutes 5 Total System Standby mA 254.2 Total System Alarm mA 2307.2 Total System Standby NH 15.25 Total System Alarm NH 0.19 Min. NH Battery 15.44 ADD 30% FOR BATTERY DEPLETION 4.63 Required NH Battery • 20.08 LA/H BATTERY PROVIDED FOR SYSTEM 1 21 KITCHEN LEGEND FACP ANN CONTROL UNIT ANNUNCIATOR MANUAL PULL BELL STROBE STROBE HORN STROBE SMOKE DETECTOR HEAT DETECTOR 1ST FLOOR PLAN SCALE 3/8' = 1'-0' TWO LINES TO CENTRAL STATION UP TO 2ND FLOOR SD UP TO 2ND FLOOR HS RJ31X CONN BLOCK RJ31 X CONN BLOCK RISER DIARAM UDACT fi-DD HEAT D're-enotV L FROM 1ST FLOOR SD BEPSOOM FROM 1ST FLOOR HS UN! ODE 200 NORTH 2ND FLOOR PLAN SCALE 3/8' = 1'-0' SCALE 3/8' = 1'-0' 120 VAC ©Q Q MP MP ACCEPTED ❑ Without Comments As Noted In Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: g/4.5 0 2 By: —rs/`Z OOOQOOOO h 7&//0/( e /Jr> cote Ccose 6 kfe-N0) /4 -e -,4X A 1 ,3-"S. 14.' >c s� 14237 INTERURBAN AVE S 02-F-174 UG - 9 2002 SECURITY SERVICES 841 POWELL AVE. SW SUITE 101 RENTON, WA 98055 (206) 624-3103 FAX: (206) 654-2189 F— u) >— (r) W 0 U (I) W (x) CO CO CO 0) N N fUKWILA FIRE DEPARTivittVk Please call: 575.4407 and give this job No. and exact address for shuti down or restoration approval. i Revision/Issue Date REPRESENTATIVE: JEFF McCLAUGHLIN CHECKED BY: — CHECKED BY DATE: APPROVED BY: — APPROVED BY DATE: — Dots 08.07.02 Scde AS—SHOWN est ADT -1