Loading...
HomeMy WebLinkAboutPP - 14925 INTERURBAN AVE S - UNKNOWN - PERMITS AND PLANS14925 INTERURBAN AVE S ASSOCIATED PERMITS 19-5-114 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 14925 Interurban Ave S, Tukwila, WA 98168 Suite Number: Floor: 1 Tenant Name: Miracle Temple Church New Tenant? ❑ - Yes Q - No Property Owner's Name: Pastor Henry Jenkins Mailing Address: same as above City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Irma Burdeyna Day Telephone: (206) 232-8569 Company Name: Columbia Fire Mailing Address:111 South Findlay Street Seattle WA 98108 inna@columbiafire.net City State Zip E-mail Address: Fax Number: (206) 340-6100 Total number of new/relocated devices or sprinkler heads: 65 heads Valuation of Project (contractor's bid price): $ 17,220 Scope of Work (please provide detailed information): Install new fire sprinkler system into an existing building PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY TIIE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. PAID BUILDING OWNER OR AUTHORIZED AGENT: SPR ' t, n19 Signature: Date: 04/15/2019 Irina Burde —TUKWILA na FIR (E 206 232-8569 Print Name: y Day Telephone: Plan Permit App.doc 1 i213 1 FU FP Pone 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Miracle Temple Church 14925 Interurban Ave S Permit No.: 19-S-114 Date: June 3, 2019 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1 "-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'/z inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • The main drain to be plumbed to sanitary sewer. • Maintain a 4 foot clear space around the sprinkler riser(s) for emergency access. • A fire department connection (FDC) is required. The FDC shall have a 30 degree down bend with a 5 -inch Storz fitting and Knox locking Storz cap. • The height of the FDC shall be 36 to 48 inches above grade. • FDC's shall be oriented in the direction of fire apparatus access, have a 4 foot clear space in front and to the sides of the connection , be appropriately signed, have the building address served by the FDC stenciled vertically in 3 -inch high white numbers on a "safety red" background directly beneath the hose connection facing the direction of vehicular access, and protected from vehicular damage. • The FDC shall be within 50 ft. of a fire hydrant. • Post Indicator Valves (PIV's) shall have the building address served by the PIV stenciled vertically in 3 -inch high white numbers on a "safety red" background, facing the direction of apparatus access. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. May30, 2019 David J. Baerman 23208 Florence Acres Rd Monroe, WA 98272 Columbia Fire 111 South Findlay Street Seattle, WA 98108 Attn: Inna Burdeyna Subject: Miracle Temple Church 14925 Interurban Avenue S. Tukwila, WA Dear Ms. Burdeyna: This letter is to confirm that I have examined the sprinlder plans and calculations for this project. This review is limited to Columbia Fire's scope of work only, which begins at a flange above the floor. Please include a copy of this letter with any submittal of the plans. Based upon my review, I have the following comments: This project appears to be a new, stand-alone building. It will be protected by one wet -pipe sprinlder system designed for Ordinary Hazard occupancy. Dry pendent sprinkler heads protect the outside canopy. The riser includes a vertical backflow preventer. A fire department connection on the side of the building is connected to the riser. It must have an automatic drain to protect it from freezing. The underground supply (by others) is 6 -inch piping. It runs from the city connection a distance of 150 feet to the building. No other details are shown for the underground piping. The roof is a wood deck on steel trusses. The space between the roof deck and the suspended ceiling is filled with insulation except for a maximum 6 -inch space above the ceiling. Thus, sprinklers are not required above the ceiling, according to Section 8.15.1.2 of NFPA 13 (2010 Edition). Section 9.2.3.4 of NFPA 13 deals with restraint of piping where the water pressure exceeds 100 psi. The static pressure at this project is 150 psi. It appears that the flexible drops to the pendent heads are secured to the ceiling so as to provide the required restraint to prevent upward movement. Seismic brace details are shown, and load calculations are included. Page 2 Hydraulic calculations: One set of hydraulic calculations has been submitted. They are based on a water supply at the city connection of 150 psi static pressure and a residual pressure of 20 psi with 4878 gpm flowilng. The system is designed for Ordinary Hazard Group 1 occupancy at a density of .15 gpm per sq. ft. over an area of 1500 sq. ft. Quick -response pendent sprinkler heads are spaced at a maximum of 130 sq. ft., and have a k -factor of 5.6. The system demand is 394.2 gpm for the sprinklers, plus an outside hose allowance of 250 gpm, at a pressure of 67.6 psi. The safety margin is 79.3 psi. Thank you for the opportunity to review these plans. I trust that this will help with the approval of the Authority Having Jurisdiction. Sincerely, David J. Baerman, P.E. EXPIRES 4 / 9 / 21 COLUMBIA FIRE, INC. 111 SOUTH FINDLAY STREET SEATTLE,WA 98108 HYDRAULIC CALCULATIONS FOR MIRACLE TEMPLE CHURCH 14925 INTERURBAN AVE S TUKWILA, WA 98168 DRAWING NUMBER: FP1.01 DATE: MAR 27, 2019 -DESIGN DATA - REMOTE AREA NUMBER: #1 REMOTE AREA LOCATION: SANCTUARY/MEDIA/CHURCH ROOM OCCUPANCY CLASSIFICATION: ORDINARY HAZARD DENSITY: 0.15 gpm/sq. ft. AREA OF APPLICATION: 1528.49 sq. ft. COVERAGE PER SPRINKLER: 130 sq. ft. TYPE OF SPRINKLERS CALCULATED: GLOBE PENDENT 5.6K NUMBER OF SPRINKLERS CALCULATED: 17 *IN -RACK SPRINKLER DEMAND: N/A gpm HOSE -STREAM DEMAND: N/A gpm TOTAL WATER REQUIRED (INCLUDING HOSE): 644.2 gpm FLOW AND PRESSURE (AT BASE OF RISER): 394.2 gpm @ 57.8 psi TYPE OF SYSTEM: NFPA 13 *VOLUME OF DRY OR PREACTION SYSTEM: N/A *DETAILS: WATER SUPPLY Source: Test Date: Test By: Location: Static: 150 psi Residual: 20 psi Flow: 4878.0 qpm Source Elevation Relative to Finished Flow Level: ft. INSTALLING CONTRACTOR Name: COLUMBIA FIRE Address: 111 S FINDLAY ST, SEATTLE, WA 98108 Phone: (206) 232-8569 Certification number: COLUMF1952MG NAME OF DESIGNER: INNA BURDEYNA AUTHORITY HAVING JURISDICTION: TUKWILA NOTES: Calculations performed by HASS under license # 27121906 granted by HRS SYSTEMS, INC. (Notes continue after pipe calculations results.) (Notes continue after pipe calculations results.) IMETITIIATU •T flu /O■ SPRINKLES /r/SSSS Steve Adamson 4265-0961-C Lard 3 COLUMF1952�i. AG i1Sn�tYn ;;L� �pMii�SSNSMNNN�N SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 3/27/2019 C:\HASS\HASSDATA\MIRACLE TEMPLE CHURCH.SDF JOB TITLE: MIRACLE TEMPLE CHURCH WATER SUPPLY ANALYSIS 160.0 C 1AL 140.0 G120.0 A U G100.0 E P 80.0 R E S 2A? s 60.0 U R E 40.0 P 20.0 s i 0.0 -14.7 Static: 150.00 psi Resid: 20.00 psi Flow: 4878.0 gpm LEGEND 1 'g Available pressure 146.93 psi @ 644.2 gpm 2 Required pressure 67.59 psi @ 644.2 gpm lA I Avail. OnSite Demand Press. 146.93 psi @ 394.2 gpm 2A '/ Req. OnSite Demand Press. 67.59 psi @ 394.2 gpm A. Source Supply Curve 10015002000 2500 3000 3500 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results 4000 4500 5000 B. System Demand Curve C. Available at Source (2) On Site pressures are based on hose stream deduction at the source SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 3/27/2019 C:\HASS\HASSDATA\MIRACLE TEMPLE CHURCH.SDF JOB TITLE: MIRACLE TEMPLE CHURCH NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SRCE 150.0 20.0 4878.0 146.9 644.2 67.6 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 644.2 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 250.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 394.2 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (FT) (PSI) (GPM) 1A 9.0 K= 5.60 14.8 21.6 2A 9.0 K= 5.60 15.0 21.7 3A 9.0 K= 5.60 15.9 22.3 4A 9.0 K= 5.60 18.4 24.0 5A 9.0 K= 5.60 22.9 26.8 7A 9.0 K= 5.60 12.1 19.5 7B 9.0 K= 5.60 12.5 19.8 8A 9.0 K= 5.60 13.5 20.6 9A 9.0 K= 5.60 15.6 22.1 10A 9.0 K= 5.60 19.4 24.7 11A 9.0 K= 5.60 25.3 28.2 13A 9.0 K= 5.60 14.6 21.4 14A 9.0 K= 5.60 14.9 21.6 15A 9.0 K= 5.60 16.1 22.5 16A 9.0 K= 5.60 18.6 24.2 17A 9.0 K= 5.60 22.2 26.4 18A 9.0 K= 5.60 22.9 26.8 1 10.5 - - - - 17.8 2 10.5 17.9 3 10.5 19.1 4 10.5 22.1 5 10.5 27.6 6 10.5 54.3 7 10.5 15.0 8 10.5 16.1 9 10.5 18.8 10 10.5 23.4 11 10.5 31.0 12 10.5 54.4 13 10.5 17.5 14 10.5 17.9 15 10.5 19.3 16 10.5 22.4 17 10.5 26.8 18 10.5 28.6 19 10.5 54.6 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 3/27/2019 C:\HASS\HASSDATA\MIRACLE TEMPLE CHURCH.SDF JOB TITLE: MIRACLE TEMPLE CHURCH NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (FT) (PSI) (GPM) TOR 10.5 54.8 BOR 4.0 57.8 BF2 2.0 58.8 BF1 2.0 - - - - 64.3 SRCE -3.0 SOURCE 67.6 394.2 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 3/27/2019 C:\HASS\HASSDATA\MIRACLE TEMPLE CHURCH.SDF JOB TITLE: MIRACLE TEMPLE CHURCH NFPA PIPE DATA Pipe Tag K-fac Add F1 Add F1 To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) Notes To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 1 Source 0.0 150.00 140 3.3 SRCE -3.0 67.6 394.2 BF2 D6.000 4E:88.0 135.00 2.2 BF1 2.0 64.3 394.2 6.280 T:47.0 285.00 0.004 1.1 Pipe: 2 0.0 Fixed Pressure Loss Device BF1 2.0 64.3 394.2 BOR 5.5 psi, 394.2 gpm BF2 2.0 58.8 394.2 Pipe: 3 0.0 0.0 2.00 120 0.9 BF2 2.0 58.8 394.2 TOR B4.000 0.00 0.9 BOR 4.0 57.8 394.2 4.260 2.00 0.035 0.1 Pipe: 4 0.0 0.0 6.50 120 3.0 BOR 4.0 57.8 394.2 19 B4.000 0.00 2.8 TOR 10.5 54.8 394.2 4.260 6.50 0.035 0.2 Pipe: 5 0.0 142.9 18 6.00 120 0.2 TOR 10.5 54.8 251.3 12 B4.000 0.00 0.0 19 10.5 54.6 394.2 4.260 6.00 0.035 0.2 Pipe: 6 0.0 134.9 11 14.00 120 0.2 19 10.5 54.6 116.4 6 B4.000 0.00 0.0 12 10.5 54.4 251.3 4.260 14.00 0.015 0.2 Pipe: 7 0.0 0.0 12.00 120 0.0 12 10.5 54.4 116.4 5 B4.000 0.00 0.0 6 10.5 54.3 116.4 4.260 12.00 0.004 0.0 Pipe: 8 0.0 26.8 18A 20.00 120 26.0 19 10.5 54.6 116.1 17 A1.250 0.00 0.0 18 10.5 28.6 142.9 1.380 20.00 1.301 26.0 Pipe: 9 0.0 26.4 17A 2.00 120 1.8 18 10.5 28.6 89.7 16 A1.250 0.00 0.0 17 10.5 26.8 116.1 1.380 2.00 0.886 1.8 Pipe: 10 0.0 24.2 16A 8.00 120 4.4 17 10.5 26.8 65.5 15 A1.250 0.00 0.0 16 10.5 22.4 89.7 1.380 8.00 0.550 4.4 Pipe: 11 0.0 22.5 15A 10.00 120 3.1 16 10.5 22.4 43.1 14 A1.250 0.00 0.0 15 10.5 19.3 65.5 1.380 10.00 0.307 3.1 Pipe: 12 0.0 21.6 14A 10.00 120 1.4 15 10.5 19.3 21.4 13 A1.250 0.00 0.0 14 10.5 17.9 43.1 1.380 10.00 0.141 1.4 Pipe: 13 0.0 0.0 10.00 120 0.4 14 10.5 17.9 21.4 13A A1.250 0.00 0.0 13 10.5 17.5 21.4 1.380 10.00 0.039 0.4 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 3/27/2019 C:\HASS\HASSDATA\MIRACLE TEMPLE CHURCH.SDF JOB TITLE: MIRACLE TEMPLE CHURCH Pipe Tag K-fac Add F1 Add F1 To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) Notes To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 14 0.0 28.2 11A 20.00 120 23.4 12 10.5 54.4 106.7 10 A1.250 0.00 0.0 11 10.5 31.0 134.9 1.380 20.00 1.169 23.4 Pipe: 15 0.0 24.7 10A 10.00 120 7.6 11 10.5 31.0 82.0 9 A1.250 0.00 0.0 10 10.5 23.4 106.7 1.380 10.00 0.758 7.6 Pipe: 16 0.0 22.1 9A 10.00 120 4.7 10 10.5 23.4 59.9 8 A1.250 0.00 0.0 9 10.5 18.8 82.0 1.380 10.00 0.466 4.7 Pipe: 17 0.0 20.6 8A 10.00 120 2.6 9 10.5 18.8 39.3 7 A1.250 0.00 0.0 8 10.5 16.1 59.9 1.380 10.00 0.260 2.6 Pipe: 18 0.0 19.8 7B 10.00 120 1.2 8 10.5 16.1 19.5 7A A1.250 0.00 0.0 7 10.5 15.0 39.3 1.380 10.00 0.120 1.2 Pipe: 19 0.0 26.8 5A 30.00 120 26.7 6 10.5 54.3 89.6 4 A1.250 0.00 0.0 5 10.5 27.6 116.4 1.380 30.00 0.890 26.7 Pipe: 20 0.0 24.0 4A 10.00 120 5.5 5 10.5 27.6 65.6 3 A1.250 0.00 0.0 4 10.5 22.1 89.6 1.380 10.00 0.548 5.5 Pipe: 21 0.0 22.3 3A 10.00 120 3.1 4 10.5 22.1 43.2 2 A1.250 0.00 0.0 3 10.5 19.1 65.6 1.380 10.00 0.308 3.1 Pipe: 22 0.0 21.7 2A 8.00 120 1.1 3 10.5 19.1 21.6 1 A1.250 0.00 0.0 2 10.5 17.9 43.2 1.380 8.00 0.142 1.1 Pipe: 23 0.0 0.0 4.00 120 0.2 2 10.5 17.9 21.6 1A A1.250 0.00 0.0 1 10.5 17.8 21.6 1.380 4.00 0.039 0.2 Pipe: 24 5.60 21.6 Disch 24.00 120 2.9 1 10.5 17.8 0.0 A1.000 0.00 -0.6 1A 9.0 14.8 21.6 1.049 24.00 0.150 3.6 Pipe: 25 5.60 21.7 Disch 24.00 120 3.0 2 10.5 17.9 0.0 A1.000 0.00 -0.6 2A 9.0 15.0 21.7 1.049 24.00 0.151 3.6 Pipe: 26 5.60 22.3 Disch 24.00 120 3.2 3 10.5 19.1 0.0 A1.000 0.00 -0.6 3A 9.0 15.9 22.3 1.049 24.00 0.159 3.8 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 3/27/2019 C:\HASS\HASSDATA\MIRACLE TEMPLE CHURCH.SDF JOB TITLE: MIRACLE TEMPLE CHURCH Pipe Tag K-fac Add Fl Add F1 To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) Notes To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 27 5.60 24.0 Disch 24.00 120 3.7 4 10.5 22.1 0.0 A1.000 0.00 -0.6 4A 9.0 18.4 24.0 1.049 24.00 0.183 4.4 Pipe: 28 5.60 26.8 Disch 24.00 120 4.7 5 10.5 27.6 0.0 A1.000 0.00 -0.6 5A 9.0 22.9 26.8 1.049 24.00 0.224 5.4 Pipe: 29 5.60 19.5 Disch 28.00 120 2.8 7 10.5 15.0 0.0 A1.000 0.00 -0.6 7A 9.0 12.1 19.5 1.049 28.00 0.124 3.5 Pipe: 30 5.60 19.8 Disch 24.00 120 2.4 7 10.5 15.0 0.0 A1.000 0.00 -0.6 7B 9.0 12.5 19.8 1.049 24.00 0.128 3.1 Pipe: 31 5.60 20.6 Disch 24.00 120 2.6 8 10.5 16.1 0.0 A1.000 0.00 -0.6 8A 9.0 13.5 20.6 1.049 24.00 0.137 3.3 Pipe: 32 5.60 22.1 Disch 24.00 120 3.1 9 10.5 18.8 0.0 A1.000 0.00 -0.6 9A 9.0 15.6 22.1 1.049 24.00 0.157 3.8 Pipe: 33 5.60 24.7 Disch 24.00 120 4.0 10 10.5 23.4 0.0 A1.000 0.00 -0.6 10A 9.0 19.4 24.7 1.049 24.00 0.192 4.6 Pipe: 34 5.60 28.2 Disch 26.00 120 5.7 11 10.5 31.0 0.0 A1.000 0.00 -0.6 11A 9.0 25.3 28.2 1.049 26.00 0.245 6.4 Pipe: 35 5.60 21.4 Disch 24.00 120 2.9 13 10.5 17.5 0.0 A1.000 0.00 -0.6 13A 9.0 14.6 21.4 1.049 24.00 0.148 3.5 Pipe: 36 5.60 21.6 Disch 24.00 120 3.0 14 10.5 17.9 0.0 A1.000 0.00 -0.6 14A 9.0 14.9 21.6 1.049 24.00 0.151 3.6 Pipe: 37 5.60 22.5 Disch 24.00 120 3.2 15 10.5 19.3 0.0 A1.000 0.00 -0.6 15A 9.0 16.1 22.5 1.049 24.00 0.161 3.9 Pipe: 38 5.60 24.2 Disch 24.00 120 3.8 16 10.5 22.4 0.0 A1.000 0.00 -0.6 16A 9.0 18.6 24.2 1.049 24.00 0.185 4.4 Pipe: 39 5.60 26.4 Disch 24.00 120 4.6 17 10.5 26.8 0.0 A1.000 0.00 -0.6 17A 9.0 22.2 26.4 1.049 24.00 0.217 5.2 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 DATE: 3/27/2019 C:\HASS\HASSDATA\MIRACLE TEMPLE CHURCH.SDF JOB TITLE: MIRACLE TEMPLE CHURCH Pipe Tag K-fac Add Fl Add F1 To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) Notes To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 40 18 18A 10.5 9.0 NOTES (HASS): 5.60 28.6 22.9 26.8 Disch 0.0 26.8 A1.000 1.049 28.00 120 5.6 0.00 -0.6 28.00 0.224 6.3 (1) Calculations were performed by the HASS 8.8 computer program in accordance with NFPA13 (2016) under license no. 27121906 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.052 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 30.7 ft/sec at pipe 8. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) Available pressure at source node SRCE under full flow conditions is 144.66 psi with a flow of 869.04 gpm. (6) PIPE FITTINGS TABLE HASS Pipe Table Name: standard.pip PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVly BfyVly GatV1v AlmChk DPV1v Tee 1.049 2.00 5.00 2.00 5.00 6.00 1.00 10.00 2.00 5.00 1.380 3.00 6.00 2.00 7.00 6.00 1.00 10.00 10.00 6.00 PAGE: B MATERIAL: THNWL HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVly BfyVly GatVly AlmChk DPV1v NPTee 4.260 13.00 26.00 8.00 29.00 16.00 3.00 26.00 26.00 26.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 9 DATE: 3/27/2019 C:\HASS\HASSDATA\MIRACLE TEMPLE CHURCH.SDF JOB TITLE: MIRACLE TEMPLE CHURCH PAGE: D MATERIAL: DIRON HWC: 140 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G N Ell Tee LngEll ChkV1v BfyVly GatV1v NPTee 6.280 22.00 47.00 14.00 51.00 16.00 5.00 47.00 Size and Type of Pipe TOLBraceTM Seismic Calculations Project Address: Miracle Temple Church E=T•N Powering 8usinesswerfdvrde on 2016 NFPA Pamphlet #13 14925 Interurban Ave S Tukwila, WA 98168 Job # 1810279 Calculations based Brace Information TOLCOTM Brace Components Maximum Spacing Maximum Brace Length Bracing Material Angle from Vertical Least Rad. of Gyration UR Value Max Horizontal Load Force Factor (Cp) 15' 0" (4.57 m) TOLCOTM Component Fig. Number Adjusted Load Fig. 1001 Clamp 1425 lbs (646 kg) Fig.980 Universal Swivel 1425 lbs (646 kg) *Calculation Based on CONCENTRIC Loading *Please Note: These calculations are for TOLCOT*' components only. Use of any other components voids these calculations and the listing of the assembly. 7' 0" (2.13 m) 1" Sch.40 45° Min. 0.42" (11 mm) Assembly Detail TOLCO FIG. 98' UNIVERSAL SWAY BRACE ATTACHMENT STEEL PIPE •�� (CV ER FC) iz P.t-7 . c TAM p) 200 1310 lbs (594 kg) 0.7 104 lbs (47.18 kg) Total Adjusted Load of all pipe within Zone of Influence Fastener Information '; . f. Fastener Orientation Maximum Load Diameter Length Type NFPA Type B §.9.2.11231.9)( s 36�� TOLCO FIG. 1001 V FAST CLAMP �♦ , '• 3/4in. (19 mm) Minimum 4x Wood Member Dual Through -Bolts - Fig.906 Brace Identification on Plans Lateral Orientation of Brace Lateral Size and Type of Pipe I Total Length Total Calculated Load ` 4" Sch.10 Steel Pipe (101.6 mm) 15ft (4.6 m) 124 lbs (56 kg) 1.25" Sch.40 Steel Pipe (31.75 mm) 158.34ft (48.3 m) 325 lbs (147 kg) 1" Sch.40 Steel Pipe 425.4 mm),.:, • WASH' ,TAT[ CERTIFICATE OF CUT ION EOMI Steve Adamson 4265-0961-C Level 3 •Columbia Fire, Inc. COLUMF1952MG __ Expires 169ft (51.5 m) 243 lbs (110 kg) 1FIR[ r..; • 0..' n ( ;" 44 4 ' • (CV ER FC) iz P.t-7 . c TAM p) SlBnature --,---.-, Percentage added for Fittings and Sprinklers 15% 104 lbs (47.18 kg) Total Adjusted Load of all pipe within Zone of Influence 795 lbs (361 kg) (TOLBraceT"' Version 8} / Ir Use of TOLBraceT"' is subject to terms and conditions per the end user license agreement TOLBraceTM Seismic Calculations Miracle Temple Church 14925 Interurban Ave S Brace Identification Brace Type (Per NFPA#13) Braced Pipe Spacing of Brace Orientation of Brace Bracing Material Maximum Brace Length Slenderness Ratio used for Load Calculation True Angle of Brace for Calculation Type of Fastener Length of Fastener Job # 1810279 E:'T•N Powsing Business 6lbddwide Lateral NFPA Type B 4" Sch.10 Steel Pipe 15' 0" (4.57 m) Lateral 1" Sch.40 7'0"(2.13m) 200 45° 3/4 (19 mm) Dual Through -Bolts Perpendicular to Beam - TOLCO Fig 9C Minimum 4x Wood Member Summary of Pipe within Zone of Influence 4" Sch.10 Steel Pipe (101.6 mm) 15ft(4.6m) 1.25" Sch.40 Steel Pipe (31.75 mm) 158.34ft (48.3 m) 1" Sch.40 Steel Pipe (25.4 mm) 169ft (51.5 m) G -Factor Used 0.7 Allowance for Heads and Fittings Conclusions Total Adjusted Load of Pipe in Zone of Influence Material Capacity Fastener Capacity Fig. 1001 Clamp Fig.980 Universal Swivel Structural Member 15% 795 lbs (361 kg) 1310 lbs (594 kg) 800 lbs (363 kg) 1425 lbs (646 kg) 1425 lbs (646 kg) Wood trusses Calculations prepared by Inna Burdeyna * The description of the Structural Member is for informational purposes only. TOLBrace'" software calculates the brace assembly only, not the structure it is attached to. Calculated with TOLBrace"" 8 Visit us at www.tolco.com EXPIRES 4/9/2 1 r Size and Type of Pipe Total Length Total Calculated Load TOLBraceTM Seismic Calculations Project Address: Miracle Temple Church E=TlN Riming eusi y.Wartalade on 2016 NFPA Pamphlet#13 14925 Interurban Ave S Tukwila, WA 98168 Job # 1810279 Calculations based Brace Information TOLCOTM Brace Components Maximum Spacing Maximum Brace Length Bracing Material Angle from Vertical Least Rad. of Gyration UR Value Max Horizontal Load Force Factor (Cp) 30' 0" (9.14 m) TOLCOTiM Component Fig. Number Adjusted Load Fig. 4L Clamp 1425 lbs (646 kg) Fig.980'Universal Swivel 1425 lbs (646 kg) *Calculation Based on CONCENTRIC Loading *Please Note: These calculations are for TOLCO components only. Use of any other components voids these calculations and the listing of the assembly. 7' 0" (2.13 m) 1" Sch.40 45° Min. 0.42" (11 mm) Assembly TOLCO UNIVERSAL SWAY ATTACHMENT STEEL TOLCO FIG. 4L iM PIPE CLAMP FOR ____ SWAY BRACING ;' FIG. — G Detail 200 1310 lbs (594 kg) 98. BRACE , �'/ PIPE i • ,',, � % 1/., O 0.7 Fastener Information Fastener Orientation Maximum Load Diameter Length Type NFPA Type B 600 lbs (272 kg) 3/4in. (19 mm) 5-1/2 in. (140 mm) Dual Lag Bolts - Fig.906 Brace Identification on Plans Longitudinal Orientation of Brace Longitudinal Size and Type of Pipe Total Length Total Calculated Load 4" Sch.10 Steel Pipe (101.6 mm) 130ft (9.1 m) 1247 lbs (112 kg) TTASNI STATE CSATISICAT■ OF CSN TIER IOS SPINN S . Y t • Steve Adanson • 4265-0961-C1, Level 3 . COLUMF],952MG . ..:� Expires * • . • - (va _FOR_ R E . s. j�AD� \ � �� 51•.lgnature/�� a Percentage added for Fittings and Sprinklers 15% 37 lbs (16.79 kg) Total Adjusted Load of all pipe within Zone of Influence 284 lbs (129 kg) {TOLBraceT.. Version 81 -- Use of TOLBraceTM is subject to terms and conditions per the end user license agreement 1 TOLBraceTM Seismic Calculations Miracle Temple Church 14925 Interurban Ave S Brace Identification Brace Type (Per NFPA#13) Braced Pipe Spacing of Brace Orientation of Brace Bracing Material Maximum Brace Length Slenderness Ratio used for Load Calculation True Angle of Brace for Calculation Type of Fastener Length of Fastener Job # 1810279 Pcmainp Business Worldwide Longitudinal NFPA Type B 4" Sch.10 Steel Pipe 30' 0" (9.14 m) Longitudinal 1" Sch.40 7'0"(2.13m) 200 45° 3/4 x 5-1/2 (19 x 140 mm) Dual Lag Bolts Parallel to Beam - TOLCO Fig 5-1/2 in. (140 mm) Summary of Pipe within Zone of Influence 4" Sch.10 Steel Pipe (101.6 mm) 30ft (9.1 m) G -Factor Used 0.7 Allowance for Heads and Fittings Conclusions Total Adjusted Load of Pipe in Zone of Influence Material Capacity Fastener Capacity Fig. 4L Clamp Fig.980 Universal Swivel Structural Member 15% 284 lbs (129 kg) 1310 lbs (594 kg) 600 lbs (272 kg) 1425 lbs (646 kg) 1425 lbs (646 kg) Wood trusses Calculations prepared by Irina Burdeyna " The description of the Structural Member is for informational purposes only. TOLBrace" software calculates the brace assembly only, not the structure it is attached to. Calculated with TOLBrace"8 Visit us at www.tolco.com EXPIRES 4/9/71 I i1 -$-I19 COLUMBIA FIRE, INC. 111 SOUTH FINDLAY STREET SEATTLE,WA 98108 HYDRAULIC CALCULATIONS FOR MIRACLE TEMPLE CHURCH 14925 INTERURBAN AVE S TUKWILA, WA 98168 DRAWING NUMBER: FP1.01 DATE: MAR 27, 2019 -DESIGN DATA - REMOTE AREA NUMBER: #1 REMOTE AREA LOCATION: SANCTUARY/MEDIA/CHURCH ROOM OCCUPANCY CLASSIFICATION: ORDINARY HAZARD DENSITY: 0.15 gpm/sq. ft. AREA OF APPLICATION: 1528.49 sq. ft. COVERAGE PER SPRINKLER: 130 sq. ft. TYPE OF SPRINKLERS CALCULATED: GLOBE PENDENT 5.6K NUMBER OF SPRINKLERS CALCULATED: 17 *IN -RACK SPRINKLER DEMAND: N/A gpm HOSE -STREAM DEMAND: N/A gpm TOTAL WATER REQUIRED (INCLUDING HOSE): 644.2 gpm FLOW AND PRESSURE (AT BASE OF RISER): 394.2 gpm @ 57.8 psi TYPE OF SYSTEM: NFPA 13 *VOLUME OF DRY OR PREACTION SYSTEM: N/A *DETAILS: WATER SUPPLY Source: Test Date: Test By: Location: Static: 150 psi Residual: 20 psi Flow: 4878.0 gpm Source Elevation Relative to Finished Flow Level: ft. INSTALLING CONTRACTOR Name: COLUMBIA FIRE Address: 111 S FINDLAY ST, SEATTLE, WA 98108 Phone: (206) 232-8569 Certification number: COLUMFI952MG NAME OF DESIGNER: INNA BURDEYNA AUTHORITY HAVING JURISDICTION: TUKWILA NOTES: Calculations performed by HASS under license # 27121906 granted by HRS SYSTEMS, INC. (Notes continue after pipe calculations results.) (Notes continue after pipe calculations results.) 1 EXPIRES 4/9/2- 1111111*wIcw•U •r MIRE ION 11.111 Steve Adamson 4265-0961-C Level 3 Columbia Fire Inc. •Veirfamativiad COLUMF1952�VIG NO SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 3/27/2019 C:\HASS\HASSDATA\MIRACLE TEMPLE CHURCH.SDF JOB TITLE: MIRACLE TEMPLE CHURCH WATER SUPPLY ANALYSIS 160.0 C 1A1 140.0 G120.0 A U G100.0 E P R E S 80.0 2A? s 60.0 U R E 40.0 P 20.0 s i 0.0 Static: 150.00 psi Resid: 20.00 psi Flow: 4878.0 gpm LEGEND 1 g Available pressure 146.93 psi @ 644.2 gpm 2 I Required pressure 67.59 psi @ 644.2 gpm lA I Avail. OnSite Demand Press. 146.93 psi @ 394.2 gpm 2A M Req. OnSite Demand Press. 67.59 psi @ 394.2 gpm A. Source Supply Curve -14.7 1 1 1 I I I ',1?:`, ; .4 'i' 10015002000 2500 3000 3500 , `' jf�b0, ,,, 504 \'- 1. 5000 FLOW (GPM) ' '' Y (1) Dashed Lines indicate extrapola .e''d va s,A,frdtri,7 t Results Note: B. System Demand Curve C. Available at Source (2) On Site pressures are based P onei.gea`-�c� 4 T tion at the source SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 3/27/2019 C:\HASS\HASSDATA\MIRACLE TEMPLE CHURCH.SDF JOB TITLE: MIRACLE TEMPLE CHURCH NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SRCE 150.0 20.0 4878.0 146.9 644.2 67.6 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 644.2 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 250.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 394.2 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (FT) (PSI) (GPM) 1A 9.0 K= 5.60 14.8 21.6 2A 9.0 K= 5.60 15.0 21.7 3A 9.0 K= 5.60 15.9 22.3 4A 9.0 K= 5.60 18.4 24.0 5A 9.0 K= 5.60 22.9 26.8 7A 9.0 K= 5.60 12.1 19.5 7B 9.0 K= 5.60 12.5 19.8 8A 9.0 K= 5.60 13.5 20.6 9A 9.0 K= 5.60 15.6 22.1 10A 9.0 K= 5.60 19.4 24.7 11A 9.0 K= 5.60 25.3 28.2 13A 9.0 K= 5.60 14.6 21.4 14A 9.0 K= 5.60 14.9 21.6 15A 9.0 K= 5.60 16.1 22.5 16A 9.0 K= 5.60 18.6 24.2 17A 9.0 K= 5.60 22.2 26.4 18A 9.0 K= 5.60 22.9 26.8 1 10.5 17.8 2 10.5 17.9 3 10.5 19.1 4 10.5 22.1 5 10.5 27.6 6 10.5 54.3 7 10.5 15.0 8 10.5 16.1 9 10.5 18.8 10 10.5 23.4 11 10.5 31.0 12 10.5 54.4 13 10.5 17.5 14 10.5 17.9 15 10.5 19.3 16 10.5 22.4 17 10.5 26.8 18 10.5 28.6 19 10.5 54.6 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 3/27/2019 C:\HASS\HASSDATA\MIRACLE TEMPLE CHURCH.SDF JOB TITLE: MIRACLE TEMPLE CHURCH NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (FT) (PSI) (GPM) TOR 10.5 54.8 BOR 4.0 57.8 BF2 2.0 58.8 BF1 2.0 - - - - 64.3 SRCE -3.0 SOURCE 67.6 394.2 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 3/27/2019 C:\HASS\HASSDATA\MIRACLE TEMPLE CHURCH.SDF JOB TITLE: MIRACLE TEMPLE CHURCH NFPA PIPE DATA Pipe Tag K-fac Add F1 Add F1 To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) Notes To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 1 Source 0.0 150.00 140 3.3 SRCE -3.0 67.6 394.2 BF2 D6.000 4E:88.0 135.00 2.2 BF1 2.0 64.3 394.2 6.280 T:47.0 285.00 0.004 1.1 Pipe: 2 0.0 Fixed Pressure Loss Device BF1 2.0 64.3 394.2 BOR 5.5 psi, 394.2 gpm BF2 2.0 58.8 394.2 Pipe: 3 0.0 0.0 2.00 120 0.9 BF2 2.0 58.8 394.2 TOR B4.000 0.00 0.9 BOR 4.0 57.8 394.2 4.260 2.00 0.035 0.1 Pipe: 4 0.0 0.0 6.50 120 3.0 BOR 4.0 57.8 394.2 19 B4.000 0.00 2.8 TOR 10.5 54.8 394.2 4.260 6.50 0.035 0.2 Pipe: 5 0.0 142.9 18 6.00 120 0.2 TOR 10.5 54.8 251.3 12 B4.000 0.00 0.0 19 10.5 54.6 394.2 4.260 6.00 0.035 0.2 Pipe: 6 0.0 134.9 11 14.00 120 0.2 19 10.5 54.6 116.4 6 B4.000 0.00 0.0 12 10.5 54.4 251.3 4.260 14.00 0.015 0.2 Pipe: 7 0.0 0.0 12.00 120 0.0 12 10.5 54.4 116.4 5 B4.000 0.00 0.0 6 10.5 54.3 116.4 4.260 12.00 0.004 0.0 Pipe: 8 0.0 26.8 18A 20.00 120 26.0 19 10.5 54.6 116.1 17 A1.250 0.00 0.0 18 10.5 28.6 142.9 1.380 20.00 1.301 26.0 Pipe: 9 0.0 26.4 17A 2.00 120 1.8 18 10.5 28.6 89.7 16 A1.250 0.00 0.0 17 10.5 26.8 116.1 1.380 2.00 0.886 1.8 Pipe: 10 0.0 24.2 16A 8.00 120 4.4 17 10.5 26.8 65.5 15 A1.250 0.00 0.0 16 10.5 22.4 89.7 1.380 8.00 0.550 4.4 Pipe: 11 0.0 22.5 15A 10.00 120 3.1 16 10.5 22.4 43.1 14 A1.250 0.00 0.0 15 10.5 19.3 65.5 1.380 10.00 0.307 3.1 Pipe: 12 0.0 21.6 14A 10.00 120 1.4 15 10.5 19.3 21.4 13 A1.250 0.00 0.0 14 10.5 17.9 43.1 1.380 10.00 0.141 1.4 Pipe: 13 0.0 0.0 10.00 120 0.4 14 10.5 17.9 21.4 13A A1.250 0.00 0.0 13 10.5 17.5 21.4 1.380 10.00 0.039 0.4 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 3/27/2019 C:\HASS\HASSDATA\MIRACLE TEMPLE CHURCH.SDF JOB TITLE: MIRACLE TEMPLE CHURCH Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) Notes To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 14 0.0 28.2 11A 20.00 120 23.4 12 10.5 54.4 106.7 10 A1.250 0.00 0.0 11 10.5 31.0 134.9 1.380 20.00 1.169 23.4 Pipe: 15 0.0 24.7 10A 10.00 120 7.6 11 10.5 31.0 82.0 9 A1.250 0.00 0.0 10 10.5 23.4 106.7 1.380 10.00 0.758 7.6 Pipe: 16 0.0 22.1 9A 10.00 120 4.7 10 10.5 23.4 59.9 8 A1.250 0.00 0.0 9 10.5 18.8 82.0 1.380 10.00 0.466 4.7 Pipe: 17 0.0 20.6 8A 10.00 120 2.6 9 10.5 18.8 39.3 7 A1.250 0.00 0.0 8 10.5 16.1 59.9 1.380 10.00 0.260 2.6 Pipe: 18 0.0 19.8 7B 10.00 120 1.2 8 10.5 16.1 19.5 7A A1.250 0.00 0.0 7 10.5 15.0 39.3 1.380 10.00 0.120 1.2 Pipe: 19 0.0 26.8 5A 30.00 120 26.7 6 10.5 54.3 89.6 4 A1.250 0.00 0.0 5 10.5 27.6 116.4 1.380 30.00 0.890 26.7 Pipe: 20 0.0 24.0 4A 10.00 120 5.5 5 10.5 27.6 65.6 3 A1.250 0.00 0.0 4 10.5 22.1 89.6 1.380 10.00 0.548 5.5 Pipe: 21 0.0 22.3 3A 10.00 120 3.1 4 10.5 22.1 43.2 2 A1.250 0.00 0.0 3 10.5 19.1 65.6 1.380 10.00 0.308 3.1 Pipe: 22 0.0 21.7 2A 8.00 120 1.1 3 10.5 19.1 21.6 1 A1.250 0.00 0.0 2 10.5 17.9 43.2 1.380 8.00 0.142 1.1 Pipe: 23 0.0 0.0 4.00 120 0.2 2 10.5 17.9 21.6 1A A1.250 0.00 0.0 1 10.5 17.8 21.6 1.380 4.00 0.039 0.2 Pipe: 24 5.60 21.6 Disch 24.00 120 2.9 1 10.5 17.8 0.0 A1.000 0.00 -0.6 1A 9.0 14.8 21.6 1.049 24.00 0.150 3.6 Pipe: 25 5.60 21.7 Disch 24.00 120 3.0 2 10.5 17.9 0.0 A1.000 0.00 -0.6 2A 9.0 15.0 21.7 1.049 24.00 0.151 3.6 Pipe: 26 5.60 22.3 Disch 24.00 120 3.2 3 10.5 19.1 0.0 A1.000 0.00 -0.6 3A 9.0 15.9 22.3 1.049 24.00 0.159 3.8 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 3/27/2019 C:\HASS\HASSDATA\MIRACLE TEMPLE CHURCH.SDF JOB TITLE: MIRACLE TEMPLE CHURCH Pipe Tag K-fac Add F1 Add F1 To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) Notes To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 27 5.60 24.0 Disch 24.00 120 3.7 4 10.5 22.1 0.0 A1.000 0.00 -0.6 4A 9.0 18.4 24.0 1.049 24.00 0.183 4.4 Pipe: 28 5.60 26.8 Disch 24.00 120 4.7 5 10.5 27.6 0.0 A1.000 0.00 -0.6 5A 9.0 22.9 26.8 1.049 24.00 0.224 5.4 Pipe: 29 5.60 19.5 Disch 28.00 120 2.8 7 10.5 15.0 0.0 A1.000 0.00 -0.6 7A 9.0 12.1 19.5 1.049 28.00 0.124 3.5 Pipe: 30 5.60 19.8 Disch 24.00 120 2.4 7 10.5 15.0 0.0 A1.000 0.00 -0.6 7B 9.0 12.5 19.8 1.049 24.00 0.128 3.1 Pipe: 31 5.60 20.6 Disch 24.00 120 2.6 8 10.5 16.1 0.0 A1.000 0.00 -0.6 8A 9.0 13.5 20.6 1.049 24.00 0.137 3.3 Pipe: 32 5.60 22.1 Disch 24.00 120 3.1 9 10.5 18.8 0.0 A1.000 0.00 -0.6 9A 9.0 15.6 22.1 1.049 24.00 0.157 3.8 Pipe: 33 5.60 24.7 Disch 24.00 120 4.0 10 10.5 23.4 0.0 A1.000 0.00 -0.6 10A 9.0 19.4 24.7 1.049 24.00 0.192 4.6 Pipe: 34 5.60 28.2 Disch 26.00 120 5.7 11 10.5 31.0 0.0 A1.000 0.00 -0.6 11A 9.0 25.3 28.2 1.049 26.00 0.245 6.4 Pipe: 35 5.60 21.4 Disch 24.00 120 2.9 13 10.5 17.5 0.0 A1.000 0.00 -0.6 13A 9.0 14.6 21.4 1.049 24.00 0.148 3.5 Pipe: 36 5.60 21.6 Disch 24.00 120 3.0 14 10.5 17.9 0.0 A1.000 0.00 -0.6 14A 9.0 14.9 21.6 1.049 24.00 0.151 3.6 Pipe: 37 5.60 22.5 Disch 24.00 120 3.2 15 10.5 19.3 0.0 A1.000 0.00 -0.6 15A 9.0 16.1 22.5 1.049 24.00 0.161 3.9 Pipe: 38 5.60 24.2 Disch 24.00 120 3.8 16 10.5 22.4 0.0 A1.000 0.00 -0.6 16A 9.0 18.6 24.2 1.049 24.00 0.185 4.4 Pipe: 39 5.60 26.4 Disch 24.00 120 4.6 17 10.5 26.8 0.0 A1.000 0.00 -0.6 17A 9.0 22.2 26.4 1.049 24.00 0.217 5.2 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 DATE: 3/27/2019 C:\HASS\HASSDATA\MIRACLE TEMPLE CHURCH.SDF JOB TITLE: MIRACLE TEMPLE CHURCH Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) Notes To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 40 18 18A 10.5 9.0 NOTES (HASS): 5.60 28.6 22.9 26.8 Disch 0.0 26.8 A1.000 1.049 28.00 120 5.6 0.00 -0.6 28.00 0.224 6.3 (1) Calculations were performed by the HASS 8.8 computer program in accordance with NFPA13 (2016) under license no. 27121906 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.052 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 30.7 ft/sec at pipe 8. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) Available pressure at source node SRCE under full flow conditions is 144.66 psi with a flow of 869.04 gpm. (6) PIPE FITTINGS TABLE HASS Pipe Table Name: standard.pip PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVly BfyVly GatVly AlmChk DPV1v Tee 1.049 2.00 5.00 2.00 5.00 6.00 1.00 10.00 2.00 5.00 1.380 3.00 6.00 2.00 7.00 6.00 1.00 10.00 10.00 6.00 PAGE: B MATERIAL: THNWL HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVly BfyVly GatV1v AlmChk DPV1v NPTee 4.260 13.00 26.00 8.00 29.00 16.00 3.00 26.00 26.00 26.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 9 DATE: 3/27/2019 C:\HASS\HASSDATA\MIRACLE TEMPLE CHURCH.SDF JOB TITLE: MIRACLE TEMPLE CHURCH PAGE: D MATERIAL: DIRON HWC: 140 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G N Ell Tee LngEll ChkVly BfyVly GatVly NPTee 6.280 22.00 47.00 14.00 51.00 16.00 5.00 47.00 Without Cor As Notes Per The .Attaci ,,., SCOPE OF WORK: 1. COLUMBIA FIRE INC. SCOPE OF WORK IS TO INSTALL FIRE SPRINKLER SYSTEM TO COMPLY WITH NFPA #13-2016. 2. SPRINKLER PLAN SUBMIT TO THE CITY OF TUKWILA FOR APPROVAL. 3. MATERIALS PER NFPA #13-2016 EDITION STANDARDS. 4. TESTING PER NFPA #13-2016 EDITION AND THE CITY OF TUKWILA. ase plans have been reviewed b•; :nEi Tukwila i=lre -ention Bureau I'm conforman;t:.:;t current City ndar`ds. Acceprf: a.- is subject to Mors and Issions which ch ,uis authorize vioiatiol l:i adopted . r lards and o, d=n'=: ices. The res nsii}'ilc ror the -.quacy of de_ic;7 :F5 totally with he. e aner. -1;tions, deletuo° - , cions to these drawings after 's date will void t, :e•otance and will require a submit: n° ,r : +S for subseaent approval. Final accepted:., :`q ;= „ " tle10 test and Inspection by The Tukwla Are i- rv~e t"� , sreau. Date: L- -! 9 By: ) l Wood Deck 11'-6" Fully Insulated Steel trusses SAMMY SIDEWINDER SWG 20 ATR Pendent Pendent TSU? k.A FIRE DEPARTMENT Please call 205-575-4407 and give 1:1`tlw t -a-' Perna 111 No. Iii -,S-01 and exact udci ess for shut- down or restoration pprovEl. REMOTE AREA NUMBER: 1 REMOTE AREA LOCATION: OCCUPANCY CLASSIFICATION: COMMODITY CLASSIFICATION: DENSITY: AREA OF APPLICATION: COVERAGE PER SPRINKLER: TYPE OF SPRINKLER CALCULATED: NO. OF SPRINKLER CALCULATED: TOTAL WATER REQUIRED: FROM WATER SUPPLY: AT THE BASE OF THE RISER: HANGER W/ SAMMY SIDEWINDER HANGER W/ SAMMY FOR WOOD SCALE: NTS SCALE: NTS GENERAL NOTES: 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL OR FM LISTED APPROVED. 2. PIPE LENGTH ARE SHOWN AS CUT LENGTH. 3. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA #13-2016 EDITION. 4. PIPING SHALL BE IN ACCORDANCE WITH NFPA #13-2016 EDITION. 5. JOINING OF PIPE/FITTINGS (THREADED AND WELDED) SHALL BE IN ACCORDANCE WITH NFPA #13-2016 EDITION. 6. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM. 7. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER AND/OR HIS STRUCTURAL. 8. ALL FIRE ALARMS, WIRING, MONITORING AND BEAM PENETRATION ARE TO BE INSTALLED BY OTHERS. RESPONSIBILITY OF THE OWNER AND/OR HIS STRUCTURAL. SECTION VIEW DETAIL SCALE: NTS SANCTUARY/ MEDIA/ CHURCH ROOM ORDINARY HAZARD N/A 0.15 GPM / FT2 1500 FP (ACTUAL 1528.49 FT2) 130 FT' QR 5.6K PENDENT 17 WOOD DECK FULLY INSULATED BY OWNER FLEXDROP MAX (4)90* BENDS t\\\\\\t!IIIIIImimi! I( FIB( DROP MAX. (4)90°BENDS \\\�1! I l l!I►I I II I!I I� I�� � 0 DESIGN CRITERIA: • ORDINARY HAZARD -130 MAX SPACING PER A SPRINKLER DRY A PENDENT PENDENT PENDENT PENDENT 644.2 GPM @ 67.59 PSI 394.2 GPM @ 57.8 PSI WATER SUPPLY INFORMATION AT THE TIME OF DESIGN: STATIC PRESSURE: 150.0 PSI RESIDUAL PRESSURE: SUPPLY FLOW: SOURCE: DATE: 20.0 PSI 4878.0 GPM TUKWILA WATER 03/01/2018 AUTHORITY HAVING JURISDICTION: TUKWILA FM SPRINKLER DROP DETAILS NOT TO SCALE WOOD STRUCTURE WOOD STRUCTURE SECTION VIEW SCALE: NTS 1/2"x0'-5 LAG BOLT 1 /2"x0'-5 LAG BOLT TOLCO FIG.980 SWAY ATTACH TOLCO FIG.980 SWAY ATTACH 1"SCH 40 PIPE 1"SCH 40 PIPE TOLCO FlG.4L PIPE CLAMP TOLCO FIG. 1001 PIPE CLAMP #200 LATERAL SWAY BRACE #200 LONG. SWAY BRACE 10" ELECTRIC BELL (BY OTHERS) HEAD BOX 6 (MIN.) SPARE SPRINKLER HEADS 4" SWING CHECK VALV TYCO CV -1 4" RISER MANIFOLD W/ TEST & DRAIN AND PRESSURE RELIEF VALVE FIRE DEPARTMENT CONNECTION 4" BACKFLOW PREVENTION MODEL DERINGER - 20 6"X4" STAINLESS STEEL CONCENTRIC REDUCER (POTABLE WATER) 6" FXG ADAPTOR A:vme A;..in,.• OVERHANG CANOPY TO CITY CONNECTION SPRINKLER ROOM LEVELI - FRE PROTECTION SCALE: 1/8" =1-0" 1 EXPIRES 4 / 91Z•( 1 NORTH DRAWING ABBREVIATION DRAWING SYMBOLS FABRICATION SYMBOLS SPRINKLER LEGEND REVISIONS 210 I I I 4 8 SPR - SPRIG RN - RISER NIPPLE DP - DROP FF - FINISH FLOOR TS - TOP OF STEEL OTS - OPEN TO STRUCTURE COJ - CUT ON JOB - EQ BRACING HANGER BRANCH LINE RESTRAINT - CENTER LINE - HYDRAULIC CAL NODE CM1.A - SPRINKLER MAIN FAB NUMBER SBL - SPRINKLER LINE FAB NUMBER SPRINKLER TYPE / SIN NUMBER SEMI -RECESSED PENDENT RESPONSE MODEL SYMBOL THREAD FINISH MK SEMI -RECESSED PENDENT DRY GLOBE GLOBE GL5601 GL5635 155°F 155°F WHITE CHROME CHROME WASHINGTON STATE CERTIFICATE OF CON FIRE PROTECTION SPRINKLER DATE 04/15/19 Mi ISSUED FOR PERMIT Steve Adamson 4265-0961-C Level 3 Columbia Fire Inc. COLLUMF1952MG Gr Sigh"[ure u/1/1I acle Temple Church 14925 Interurban Ave S Tukwila, WA 98168 AHJ: CITY OF TUKWILA Graphic Scale 118"=1'•0" TOTAL: 65 14925 INTERURBAN AVE S #150 19-S-114 I I Columbia Fire SPRINKLER SYSTEM SERVICE i REPAIR WA CL# COLUMFI952MG 111 South Findlay Street Seattle, WA 98108 (206) 232-8569 JOB NO. 1810279 DATE DESIGNER SCALE 05/07/2019 Irina Burdeyna 1/8" = 1'-O" LEVEL 1 - FIRE PROTECTION Owner FP Same As Above Pastor Henry Jenkins (206) 265-0815 1 .01 III PASTOR OFFICE GNB -8-7 BATHROOM GNB -8'-2' ADA BATHROOM --- 1'/{ 1 Mil E ASH FOOM T -f8' M-IIAROCM �.. -'/{ ILECR00 GWB-8'-Y GWB-8-7 I mil i`_l 14 roa o . '/{1 { i�i _ _ MSI '�" t-C� S p 1/{ ICffi� Z■ s1 1'/ 1'h 1' ,'/{ 1'rl re%-1 1!{ 1'/{ I . ! • �iii� 1�•� •-1 bi C C Cik 111 d C C- WO EN ADA MEN ADA GWB-8'-Y SHWA ACT H R 5-0 M 185 41 C C C 2A m 5A �n 5'-6" 2 -I in 3 I" G :-8'-2' ITCHE T -10' J r C�_ [Ail Co5.2 V' mill, - y ' -1 0 C • 0-6 4 3 `U 2 ." -0 2 8-0 III SA AT9� CTUA' iJ- C - 6 6" 6'-6"Z9, C PANTRY ACT 19'-4* �' 1 q'N • dT 8,_ i• •0 •' _ _ 62 , B2:2 l { @ ■' 11111111111 ' 1. �0 O C .- m JOBB :T-s,o• itki�'.� 66.4 66.5 REM OT A E '�ll Y"NEIN ! E/ IP 'Il!I C SAN°WICH CT -9': ll - MEFITINGROOM • T-8'"3- IT HOP - 8': 1 B3 11 1% (� - ■ Til4iT 13A 14A• rrll Ali■ B3.6 CI ® `' C IlarA 1�0: 1'h "A 1 !lig r -r l� B7:4 iv Y. y' { 1 . 1'h 1% ' Iir 4'. , 1 /{ 1 1Y � 1'/. 1Y4 /ff 1'h 1 •t: JJ .. - 11 . fJ c' 1 E . CHUB 1 " 1 : C n :• [�'���1♦�ti . C . 1 1 C . , . o 1 ': �. � OFFIC .- - NTRY - E , 4 :.r�l - FCT-8' r •MI 10" ELECTRIC BELL (BY OTHERS) HEAD BOX 6 (MIN.) SPARE SPRINKLER HEADS 4" SWING CHECK VALV TYCO CV -1 4" RISER MANIFOLD W/ TEST & DRAIN AND PRESSURE RELIEF VALVE FIRE DEPARTMENT CONNECTION 4" BACKFLOW PREVENTION MODEL DERINGER - 20 6"X4" STAINLESS STEEL CONCENTRIC REDUCER (POTABLE WATER) 6" FXG ADAPTOR A:vme A;..in,.• OVERHANG CANOPY TO CITY CONNECTION SPRINKLER ROOM LEVELI - FRE PROTECTION SCALE: 1/8" =1-0" 1 EXPIRES 4 / 91Z•( 1 NORTH DRAWING ABBREVIATION DRAWING SYMBOLS FABRICATION SYMBOLS SPRINKLER LEGEND REVISIONS 210 I I I 4 8 SPR - SPRIG RN - RISER NIPPLE DP - DROP FF - FINISH FLOOR TS - TOP OF STEEL OTS - OPEN TO STRUCTURE COJ - CUT ON JOB - EQ BRACING HANGER BRANCH LINE RESTRAINT - CENTER LINE - HYDRAULIC CAL NODE CM1.A - SPRINKLER MAIN FAB NUMBER SBL - SPRINKLER LINE FAB NUMBER SPRINKLER TYPE / SIN NUMBER SEMI -RECESSED PENDENT RESPONSE MODEL SYMBOL THREAD FINISH MK SEMI -RECESSED PENDENT DRY GLOBE GLOBE GL5601 GL5635 155°F 155°F WHITE CHROME CHROME WASHINGTON STATE CERTIFICATE OF CON FIRE PROTECTION SPRINKLER DATE 04/15/19 Mi ISSUED FOR PERMIT Steve Adamson 4265-0961-C Level 3 Columbia Fire Inc. COLLUMF1952MG Gr Sigh"[ure u/1/1I acle Temple Church 14925 Interurban Ave S Tukwila, WA 98168 AHJ: CITY OF TUKWILA Graphic Scale 118"=1'•0" TOTAL: 65 14925 INTERURBAN AVE S #150 19-S-114 I I Columbia Fire SPRINKLER SYSTEM SERVICE i REPAIR WA CL# COLUMFI952MG 111 South Findlay Street Seattle, WA 98108 (206) 232-8569 JOB NO. 1810279 DATE DESIGNER SCALE 05/07/2019 Irina Burdeyna 1/8" = 1'-O" LEVEL 1 - FIRE PROTECTION Owner FP Same As Above Pastor Henry Jenkins (206) 265-0815 1 .01