Loading...
HomeMy WebLinkAboutPP - 10448 47TH AVE S - MCCAMMANT HOMES - PERMITS AND PLANS10448 47TH AVE S ASSOCIATED PERMITS D98-0108 D98-0107 MCCAMMANT HOMES City of Tukwila Fire Department Project Name Address ATA— Retain current inspection schedule SEP 23 1998 John W. Rants, Mayor TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM it/f 1,404J /0 y y f iot ro 4-/ ALAS Thomas P. Keefe, Fire Chief Permit No. D!eY'0/07 Needs shift inspection Suite # Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Signature Date FINALAPP.FRM Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 City of Tukvvi'la Fire Department Fire Department Review Control #D98-0107 John W. Rants, Mayor Thomas P. Keefe, Fire Chief May 28, 1998 Re: McCammant Homes - 10448 -47th Avenue South Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. For short plat development (four single family homes or less), hydrants shall be placed so that a hydrant is within 250 feet of a building. Distance from a hydrant to a building is measured along the path of vehicular travel. Fire hydrants shall conform to American Water Works Association specifications C-502-54; it shall be compression type, equipped with two 2 1/2" N.S.T. hose ports and one 5" Storz pumper discharge port, and shall have a 1 1/4" Pentagon open -lift operating nut. The minimum fire flow and flow duration requirements for one- and two-family dwellings having a fire area which does not exceed 3,600 square feet (344.5 m2) shall be 1,000 gallons per minute (3785.4 L/min.). Fire flow and flow duration for dwellings having a fire area in excess of 3,600 square feet (344.5 m2) shall not be less than that specified in Table A -III -A-1. Exception: A reduction in required fire flow of 50 percent, as approved by the chief, is allowed when the building is provided with an approved automatic sprinkler system. (UFC Appendix III -A, sec. 5.1) In lieu of a fire hydrant, an approved residential fire sprinkler system may be installed when vehicular travel distance from the nearest hydrant exceeds 250 feet. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206) 575-4404 • Fax (206) 575-4439 City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fin? Chief Page number 2 2. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 901.4.4) Yours truly, The Tukwila Fire Prevention Bureau CC: TFD file ncd (54 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 57544139