Loading...
HomeMy WebLinkAboutPP - 10452 47TH AVE S - MCCAMMANT HOMES - PERMITS AND PLANS10452 47TH AVE S ASSOCIATED PERMITS D98-0266 City of Tukwila Fire Department FILE DEC 2 1999 John W. Rants, Mayor TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Thomas P. Keefe, Fire Chief Permit No. U0 bakc o Project Name LOIrl+ZIThrt9 0 C \AGM S Address n4s7 4-1 11m. AN) S Yil� Retain current inspection schedule Needs shift inspection Suite # Approved without correction notice _.:S Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Signature FINALAPP.FRM Rev. 2/19/98 Z,t °\°\ Date T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 City of Tukwila Fire Department Fire Department Review Control #D98-0266 (GO F L.. L.. John W. Rants, Mayor Thomas P. Keefe, Flit Chief August 25, 1998 Re: McCammant Homes - 10452 47th Avenue South Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. For short plat development (four single family homes or less), hydrants shall be placed so that a hydrant is within 250 feet of a building. Distance from a hydrant to a building is measured along the path of vehicular travel. Fire hydrants shall conform to American Water Works Association specifications C-502-54; it shall be compression type, equipped with two 2 1/2" N.S.T. hose ports and one 5" Storz pumper discharge port, and shall have a 1 1/4" Pentagon open -lift operating nut. The minimum fire flow and flow duration requirements for one- and two-family dwellings having a fire area which does not exceed 3,600 square feet (344.5 m2) shall be 1,000 gallons per minute (3785.4 L/min.). Fire flow and flow duration for dwellings having a fire area in excess of 3,600 square feet (344.5 m2) shall not be less than that specified in Table A -III -A-1. Exception: A reduction in required fire flow of 50 percent, as approved by the chief, is allowed when the building is provided with an approved automatic sprinkler system. (UFC Appendix III -A, sec. 5 1) All required hydrants and surface access roads shall be installed and made serviceable prior to and during the time of construction. (UFC 901.3) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 5754439 City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief Page number 2 2. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 901.4.4) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 575-4439