HomeMy WebLinkAboutPP - 10602 47TH AVE S - CONTEMPORARY HOMES - PERMITS AND PLANS10602 47TH AVE S
ASSOCIATED PERMITS
D2000-052
CONTEMPORARY HOMES
City of Tukwila
Steven M. Mullet, Mayor
Fire Department Thomas R. Keefe, Fire Chief
TUKWILA FIRE DEPARTMENT
FINAL APPROVAL FORM
FILE
Project Name C0r 0 t') T'`YUW1.e S
Address IND D O Z_ 4-1 4.-b All _ S
r `c1 Retain current inspection schedule
Needs shift inspection
Permit No. :)‘:9,066-
Suite #
9. Approved without correction notice
Approved with correction notice issued
Sprinklers:
Fire Alarm:
Hood & Duct:
Halon:
Monitor:
Pre -Fire:
Permits:
S {d`\A%
Authorized Signature Date
FINALAPP.FRM
Rev. 2/19/98 T.F.D. Form F.P. 85
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439
Steven M. Mullet, Mayor
Fire Department Thomas P. Keefe, Fire Chief
February 29, 2000
Fire Department Review
Control #D2000-052
(510)
Re: Contemporary Homes - 10602 47th Avenue South
Dear Sir:
The attached set of building plans have been reviewed by
The Fire Prevention Bureau and are acceptable with the
following concerns:
1. Your street address must be conspicuously posted on
the building and shall be plainly visible and legible from
the street. (UFC 901.4.4)
2. For short plat development (four single family homes
or less), hydrants shall be placed so that a hydrant is
within 250 feet of a building. Distance from a hydrant to
a building is measured along the path of vehicular travel.
(City Ordinance #1692)
Fire hydrants shall conform to American Water Works
Association specifications C-502-54; it shall be
compression type, equipped with two 2 1/2" N.S.T. hose
ports and one 5" Storz pumper discharge port, and
shall have a 1 1/4" Pentagon open -lift operating nut.
(City Ordinance #1692)
The minimum fire flow and flow duration requirements
for one- and two-family dwellings having a fire area
which does not exceed 3,600 square feet (344.5 m2)
shall be 1,000 gallons per minute (3785.4 L/min.).
Fire flow and flow duration for dwellings having a
fire area in excess of 3,600 square feet (344.5 m2)
shall not be less than that specified in Table
A -III -A-1. Exception: A reduction in required fire
flow of 50 percent, as approved by the chief, is
allowed when the building is provided with an approved
automatic sprinkler system. (UFC Appendix III -A, sec.
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439
Ciiy of Tukwila
Steven M. Mullet, Mayor
Fire Department Thomas P. Keefe, Fire Chief
Page number 2
5.1)
Any overlooked hazardous condition and/or violation of the
adopted Fire or Building Codes does not imply approval of
such condition or violation.
Yours truly,
The Tukwila Fire Prevention Bureau
cc: TFD file
ncd
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439