HomeMy WebLinkAboutPP - 16005 47TH AVE S - UNKNOWN - PERMITS AND PLANS16005 47TH AVE S
ASSOCIATED PERMITS
11-5-239
50'0'
8068 ter ace door
englnee
-beam
41
2x6
!Natt
24' olc
tine of
wiott above
4' concrete slab
10mm rebar e 24' aq
5" compacted sand
and gravel
engineered girder truss
.a101'....
self cio#er.
Weather :Itripping
Oteqtetdd ' 'liiir
TioNV-•
„.
imi
d Oolools pis.;
• or.,:*#Wk4A00111014 #9 OR it, •
434
0.,....: • POrtwr
0. r!
a et
THREECA
OAIRAG gi t
.
.
aY01 x 196.6141 4) ''
627 .$qf Pk
„„..,,.,....,f.k*--Tri-g.„,. -1,-,,,....,r!--.
resiting
gas Fireplace
install as per
manuf ers
specifications
9' x 7' o/h
garo.ge doer
engineered girder truss
3-2x10 •4t2
eni flush enolheereol won
3-2x10 t2
en (1-91nugeel"recifirbean
riiimmus
511
.47t ,
raty LIVING
ROOM
VIVil 12'9" :1 14'0°
tie
1\424.74:
T•4
x engineered scissor
trussee 24! o/c
omonmial
M4.ON
General Notes
1. OWNER TO PROVIDE ADEQUATE HEAT (40'F. MIN) TO PREVENT
SPRINKLER PIPES FROM FREEZING.
2. OWNER TO PROVIDE HARD WIRED HOME SMOKE DETECTION SYSTEM.
3. CPVC PIPE SHALL HAVE HANGERS 6'-0" c\c for 1" C.P.V.C. AND
NOT MORE THAN 6" FROM ANY SPRINKLER HEAD.
4, ALL PIPING TO BE 1" C.P.V.C. U.N.O.
5. ALL UNDERGROUND MUST BE FLUSHED BEFORE E.F.P.
CONNECTS PIPING.
6. A 6" POTTER BELL WILL BE MOUNTED ON THE EXTERIOR
APPROACH TO THE HOME.
7. ALL ATTIC PIPING MUST BE "TENTED" WITH INSULATION ON ALL PIPING.
SYM
1101111111M111111111=11
sco.le = 1/#,Y = 0"
Sprinkler Symbol Legend
SPRINKLER ORIFICE SIZE, TYPE & FINISH
Reliable RFC 43 16' x 16' TOTAL FLOW REQUIREMENT 26GPM 0 9.6 psi
c4 AsIons for brick
Included on
foundation plan only
QUAN TEMP K FACTOR
Ati 155' 4.9
Reliable F 1 RES 44 SIDEWALL
Reliable F 3 QR DRY PENDENT
0
155'
155'
4.3
Reliable F 3 QR DRY SIDEWALL 16' X 16'
TYCO DS -1 EXTENDED COVERAGE DRY SIDEWALL 16' X 20'
0
155'
155'
TOTAL 23
co
18" roof
overhang
38`61
13'2'
12'4"
10'8'
4'0"
4'10°
7'6"
6040
1
1
5040
8'2'
2'6'
BEDROOM
1.2!6° x 10'2'
IL
NOTE ("11
veriFy tub R.D. prior
to construction
and adjust walls,
accorcilrigly
desk
5' tub c/
shower,
see note -of
F -518a--1
[skylight
4'0'
5'
BEDROOM.
Lev
engineered girder truss
2 4"
c.li 2'
pocke
door
engineered roof trusses
@0.41Z-Joic —14"-
ro.lUng
oln
6'4'
x--.
2'6'
3040
t-
13
IBEDROCIM
Qa 3.017 x 13'6'
'landing
open to
•below
1
\D4
30*.
10'81
376
2'
rourdtop
5'0' • 5'0"
2'
4"9"
100"
4'9'
3'1 1/2'
17 1/5
5'9'
1
0"
10'9°
13'3"
38'6'
1
—1
-10 A)Feh 3 D
6.4A\k-tc44+44,0 Coot 5-ecii-NIN,N.S •
2'6 1-100) Art4-R_ 4,0+
.12t r9v;e4.
ThJA-r. e4.1-eJ be 1144 vic)
scale = 1/4" = 1'
Stand alone 13-D Pump and Tank Fire System Riser
System pressure gauge
_
System main draM, to be piped back to water tank
—
Potter VSR-SFG flow switch
_
l5amp 240volt 1.5 HP Pump
Swing check valve
300 gallon water tank (plastic)
Tank to have an auto fill piped by a licensed Plummer
EVIRGE-1-_-_\ HE l=)0TECTIO
10509 64th Ave E.
Puyallup, WA 98373
evergfp967iz
Phone: (253) 848-0146
DATE: 9/22/2011
REV: DRAWN: M.H.
SHEET:
o -
I \
1 OF 1
4" .2
Final acceptance is subject to field test and Inspection by
he Tukwila Fire Prevention Bureau.
By: I
Date:
TUKINILA FIRE DEPARTMENT
Please call 206-575.4407 and
0" give this Fire Permit No.
/Lm
and exact address for shut-
down or restoration approval.
!'
-TO
Lg
ti?
Without Comments
As Noted in Red
Per The Attached Letter
These plans have been reviewed by The Tukwila Fire
i')evention Bureau for conformance with current City
;:tandards. Accepnce is subject to errors and
omissions vvhici., do not authorize violations of adopted
::Adards and ordinances. The responsibility for the
iAequacy of design resi's totally with the designer,
,..dditions, deletions or. revisions to these drawings after
. this date will void tills .-.(0tarice and will require a
LT.,
resubmittal of revised drawings for subsequent approval.
Sheet Title
Fire S
Drin
Stamp
er
plc
n
Job Title
TUKWILA OJS
4633 S. 160th St.
TUKWILA, Wa.